You are on page 1of 2

G E L M A R I N E / RV BAT T E R I E S

cally i g o l o n h c t e The most tpower source afloa advanced


Longer Deep Cycle Life More Operating/Trolling Time Faster Recharge/Longer Life Ideal for Remote Locations

DOMINATOR gel batteries offer many significant advantages over conventional liquid acid batteries. Because there is no liquid electrolyte to leak or spill out of the battery, the DOMINATOR can easily be installed in hard-to-reach locations. There is no need to check fluid levels. The DOMINATORS gelled construction also eliminates vibration damage to plates. The DOMINATOR even works under water!

Great for reliable starting

UL Recognized Component

COMPLETELY COMPLETEL Y SEALED SPILLPR SPILLPROOF/LEAKPR SPILLPROOF/LEAKPROOF OOF/LEAKPROOF OOF

Features and Benefits

100% maintenance-free Ideal for engine starting and/or trolling Faster recharging Longer life No need to check electrolyte levels. Install it and forget it. Great multi-purpose battery.

GEL MARINE/RV BATTERIES

NON-SPILLABLE by DOT (Department of Transportation),


ICAO (International Commercial Airline Organization) and IATA (International Airline Transport Association) definitions. The Dominator vs. Conventional Liquid Acid Batteries
Deka introduces a marine battery second to none. The Dominator contains electrolyte that is permanently locked in a thixotropic gel, instead of conventional and messy liquid acid. Our gelled electrolyte batteries offer many significant advantages over conventional liquid acid batteries. Because there is no liquid electrolyte to leak or spill out of the battery, the Dominator can be easily installed in hard-to-reach locations. Because it has gelled electrolyte, there is no need to check fluid levels. The Dominators gelled construction also eliminates vibration damage to plates. The Dominator even works under water.

Potential Applications for the Deka Dominator Marine Battery


Buoy Lighting Communication Equipment Control Equipment Emergency Lighting Emergency Power Supply Systems
Charging at 13.8 Volts
110 100 90 F E

Engine Starting House Power Marine Equipment Navigation Beacons Radar Stations Radio Relay Stations

Safety Lighting Security Systems Ships Batteries Trolling Motors Other Deep-Discharge Applications
Gel Reserve Capacity
Discharge at 25 Amps

For quicker turnaround time. Resists damaging over-discharges. Longer operating/ Runs considerably longer trolling time than comparable wet batteries. Compu-cast grids and For maximum durability, computer-controlled oxide power and life. Sealed, recombinant Eliminates dangerous spills, construction with gassing and terminal corrosion gelled electrolyte (unless severely overcharged). Self-discharge rate Recharges to full power, even of less than 2% per if left discharged for months. month (at 68F) Thick consistency of Eliminates the damaging gelled electrolyte and effects of vibration. tight-pack construction Easy to install Convenient for hard-to-reach connection and hook-up. Over 250 quality Ensure highest quality, control checks performance and reliability. Broad line of For all your marine sizes and types power needs. Made in U.S.A Your assurance of quality.

Gel Line Ratings

Gel Charging Hours vs. Initial Charging Amps


A 8GU1HM B 8G24M 13.00

600

6.50

A 8GU1HM B 8G24M
100

D C A

G F E B

A 8GU1HM B 8G24M C 8G27M D 8G31DTM

Battery Voltage (12V)

Initial Charging Amps

80 70 60 50 40 30 20 10 0 1 2

Battery Voltage (6V)

C 8G27M D 8G31DTM E 8G4DM, 8GGC2M

C 8G27M D 8G31DTM

Amps

12.00

6.00

E 8GGC2M F 8G4DM G 8G8DM

E 8GGC2M
10

F 8G4DM G 8G8DM

D C B

F 8G8DM

11.00

5.50

A
4 5 6 7 8 9 10 11 12 13 14

B
100

C D
150 200 250 300 350

E
400

F
450

G
5.00 500
.1 .1 1 10 50 100

10.00 0 50

Time (Hours)

Minutes

Hours to 1.75 Volts per Cell

Type No. 8GU1HM 8G24M 8G27M 8G31DTM 8GGC2M 8G4DM 8G8DM

Foot Notes HZ HQ HQ HSX G HS HS

Volts 12 12 12 12 6 12 12

CCA @ 0F 175 410 505 550 585 970 1150

Res. Capacity @ 80F 44 132 160 180 345 375 475

Ref. CA @ 32F 250 575 700 780 850 1245 1470

Minutes Discharged at* 75 50 25 15 8 5 Amps Amps Amps Amps Amps Amps 5 33 40 51 92 105 135 12 57 70 84 155 175 220 47 140 170 190 375 395 500 90 245 300 335 680 685 890 190 500 605 690 1360 1385 1750 325 845 1000 1160 2200 2300 3000

Ampere Hour Capacity* 20 Hr. 6 Hr. 3 Hr. 1 Hr. Approx. Wt. Rate Rate Rate Rate Lbs. (Kgs.) 31.6 73.6 86.4 97.6 180.0 183.0 225.0 28.0 64.5 76.0 85.2 155.0 160.2 198.0 25.5 59.3 69.9 78.6 136.0 147.6 181.8 21.0 23.4 (10.6) 48.5 52.5 (23.8) 57.0 63.2 (28.7) 64.5 70.0 (31.7) 99.0 68.4 (31.0) 122.0 127.0 (57.5) 150.0 157.0 (71.1) L

Dimensions In (mm) W 514 (133) 634 (171) 634 (171) 634 (171) 718 (181) 812 (216) 11 (279) H 718 (181) 978 (251) 978 (251) 938 (238) 1078 (276) 10 (254) 10 (254)

8516 (211) 1078 (276) 1234 (324) 121516 (329) 1014 (260) 2034 (527) 2034 (527)

* NOMINAL ALL RATINGS ARE AFTER 15 CYCLES AND CONFORM TO B.C.I. SPECIFICATIONS.

All batteries manufactured in polypropylene cases and covers except where noted. IMPORTANT CHARGING INSTRUCTIONS: WARRANTY VOID IF OPENED OR IMPROPERLY CHARGED. Do not install in a sealed container. Constant under or overcharging will damage any battery and shorten its life! Use a good constant potential, voltage-regulated charger. For 12-volt batteries, charge to at least 13.8 volts but no more than 14.1 volts at 68F (20C). For 6-volt batteries, charge to at least 6.9 volts but no more than 7.05 volts at 68F (20C). The open circuit voltage of a fully charged 12-volt battery is 12.8V at 68F (20C). However, as the battery charges, the building internal pressure (voltage) causes resistance to the charge. Therefore, the on-charge voltage must be higher (at least 13.8V) to overcome this internal pressure (voltage) during charging.

FOOTNOTES: G - Offset post w/ horizontal hole, stainless steel 5/16" bolt & hex nut H - Includes handles Q - Dual terminals with SAE post and 3/8" POS., 5/16" NEG. stainless steel studs & wing nuts S - SAE automotive type post X - 3/8" x 16 stainless steel stud posts Z - Terminals have round holes

UL Recognized Recognized Comp Component MH17218

RE

LE AD

TU RN

Pb
RECYCLE

POWERED

FOR PERFORMANCE

DISTRIBUTED BY:

Lyon Station, PA 19536-0147 Phone: 610-682-6361 Fax: 610-682-4781

Order Department Hotline: 610-682-4231


www.dekabatteries.com e-mail: eastpenn@eastpenn-deka.com
E.P.M. Form No. 0909 Rev. 2/06 2006 by EPM Printed in U.S.A.
No part of this document may be copied or reproduced, electronically or mechanically, without written permission from the company.