Professional Documents
Culture Documents
w w w. n u m a t i c s . c o m
Table of Contents
Air Bellows
Single Convoluted ASNS10-2-1 ASNS11-1-1 ASNS11-2-1 ASNS11-3-1 ASNS18-3-1 ASNS18-4-1 ASNS18-5-1 ASNS31-3-1 ASNS51-3-1 ASNS82-4-1 ASNS82-5-1 Double Convoluted ASND10-4-1 ASND11-4-1 ASND18-4-1 ASND18-5-1 ASND18-6-1 ASND31-6-1 ASND31-8-1 ASND51-7-1 ASND51-8-1 ASND82-7-1 ASND82-10-1 ASND154-8-1 Triple Convoluted ASNT51-11-1 ASNT82-12-1 ASNT154-12-1 Sleeve Type ASNC2-1-1 ASNC6-1-1 ASNC6-2-1 ASNC6-3-1 ASNC8-4-1 3-13 3 4 5 6 7 8 9 10 11 12 13 14-25 14 15 16 17 18 19 20 21 22 23 24 25 26-28 26 27 28 29-33 29 30 31 32 33
ASNS10-2-1
2.0 1.8
H
1.6
100 psi
Vo
3.55 DIA max. 5.71 DIA 6.30 DIA Installation space needed
Volume (in 3)
24 20
lum e
80 psi
60 psi
Air inlet
16 12 8
20 psi 40 psi
4 0
4.0
3.5
3.0
2.5
2.0
0.79
Hmax = 4.33
Force-Height Diagram
Height H (in)
Hmin = 2.0
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 27 lbs 2.1 lbs
Order Data
Type With Clamped Plates 1/8 NPTF air inlet Model Number ASNS10-2-1
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
ASNS11-1-1
2.5
125
2.0
100 psi
4.25 DIA max. 5.91 DIA 6.50 DIA Installation space needed
100
Volume (in 3)
80 psi
1.5
75
Vo lu
me
60 psi
1.0
Air Inlet
50
40 psi
0.5 25
20 psi
Hmax = 3.7
Force-Height Diagram
Height H (in)
Hmin = 2.0
1.75
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 56 lbs 2.7 lbs
Order Data
Type With clamped plates 1/4 NPTF air inlet Model Number ASNS11-1-1
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
ASNS11-2-1
4.25 DIA max. 6.50 DIA 7.09 DIA Installation space needed
Air inlet
1.75
Force-Height Diagram
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 45 lbs 2.7 lbs
Order Data
Type With Clamped Plates 1/4 NPTF Air Inlet Additional types on request Model Number ASNS11-2-1
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
ASNS11-3-1
3.5
3.0
4.25 DIA max. 7.88 DIA 8.46 DIA Installation space needed
150
2.5
Volume (in3)
120
80 psi
2.0
100 psi
90
60 psi
Volu me
1.5
air inlet
60
40 psi
1.0
30
20 psi
0.5
0.0 2.0
Hmax = 5.9
Force-Height Diagram
Height H (in)
Hmin = 2.0
1.75
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 45 lbs 3.1 lbs
Order Data
Type With clamped plates 1/4 NPTF air inlet Model Number ASNS11-3-1
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
ASNS18-3-1
5.55 DIA max. 8.47 DIA 9.06 DIA Installation space needed
Air inlet
2.75
Force-Height Diagram
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 45 lbs 4.5 lbs
Order Data
Type With Clamped Plates 3/4 NPTF Air Inlet 1/4 NPTF Air Inlet Model Number ASNS18-3-1 ASNS18-3-1-2
Installation Instruction Torque rating Mounting Holes 3/8 = 15-20 lb-ft Air Inlet 3/4 NPTF = 40-50 lb-ft Air Inlet 1/4 NPTF = 12-15 lb-ft
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
ASNS18-4-1
5.0
H
100 psi
5.55 DIA max. 9.1 DIA 9.65 DIA Installation space needed
Volume (in 3)
150 125 100 75 50 25 0 6.0 5.5 5.0 4.5 4.0 3.5 3.0
Vol um e
80 psi
60 psi
Air Inlet
40 psi
20 psi
2.5
2.0
Hmax = 5.9
Force-Height Diagram
Height H (in)
Hmin = 2.0
2.75
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 45 lbs 4.2 lbs
Order Data
Type With clamped plates 3/4 NPTF air inlet 1/4 NPTF air inlet Additional types on request Model Number ASNS18-4-1 ASNS18-4-1-2
Installation Instructions - Torque rating Mounting Holes 3/8 = 15-20 lb-ft Air Inlet 3/4" NPTF = 40-50 lb-ft Air Inlet 1/4 NPTF = 12-15 lb-ft
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
ASNS18-5-1
4.5
200
3.5
5.55 DIA max. 9.25 DIA 9.84 DIA Installation space needed
Volume (in3)
150
Vo lu
me
80 psi
3.0
Air inlet
1.5
50 20 psi
1.0
0.5
0 7.0 Hmax=6.7 6.5 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0
0.0
Height H (in)
Hmin=2.0
2.75
Force-Height Diagram
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 45 lbs 4.2 lbs
Order Data
Type With Clamped Plates 3/4 NPTF Air Inlet 1/4 NPTF Air Inlet Additional types on request Model Number ASNS18-5-1 ASNS18-5-1-2
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
ASNS31-3-1
6.34 DIA max. 9.84 DIA 10.43 DIA Installation space needed
Air inlet
1.50
3.50
Force-Height Diagram
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 45 lbs 5.1 lbs
Order Data
Type With clamped plates 3/4 NPTF air inlet 1/4 NPTF air inlet Model Number ASNS18-3-1 ASNS18-3-1-2
Installation Instruction Torque rating Mounting Holes 3/8 = 15-20 lb-ft Air Inlet 1/4" NPTF = 12-15lb-ft Air Inlet 3/4 NPTF = 40-50 lb-ft
10
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
ASNS51-3-1
12
H
500
Vo lum e
Use in green range >5.5 only after consultation with Numatics 100 psi
10
8.98 DIA
400
8
80 psi
Volume ( in3)
300
6
60 psi
Air inlet
200
40 psi
4
2.88
100
20 psi
Hmax = 6.0
Force-Height Diagram
Height H (in)
Hmin = 2.2
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 67 lbs 9.1 lbs
Order Data
Type With clamped plates 3/4 NPTF air inlet 2.8 inch excentrical 1/4 NPTF air inlet ASNS51-3-1 ASNS51-3-1-2 Model Number
Installation instruction - Torque Rating Mounting Holes 3/8 = 15-20 LB-FT Air Inlet 3/4 NPTF = 40-50 LB-FT Air Inlet 1/4 NPTF = 12-15 LB-FT
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
11
ASNS82-4-1
11.30 DIA max. 15.95 DIA 16.55 DIA Installation space needed
Air inlet
6.25
6.25
Force-Height Diagram
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 67 lbs 12.9 lbs
Order Data
Type With clamped plates 3/4 NPTF air inlet 3.12 inch excentrical 1/4 NPTF air inlet Model Number ASNS82-4-1 ASNS82-4-1-2
Installation Instruction Torque rating Mounting Holes 3/8 = 15-20 lb-ft Air Inlet 1/4" NPTF = 12-15lb-ft Air Inlet 3/4 NPTF = 40-50 lb-ft
12
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
ASNS82-5-1
18 16
H
Vo lum e
100 psi
14
11.30 DIA max. 15.95 DIA 16.55 DIA Installation space needed
12
80 psi
Volume (in 3)
10 8 6 4
Air inlet
40 psi
6.25
100 0 7 6 5 4 3 2
2 0
Hmax = 7.3
Force-Height Diagram
Height H (in)
Hmin = 2.0
6.25
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 67 lbs 13.5 lbs
Order Data
Type With clamped plates 3/4 NPTF air inlet 3.12 inch excentrical 1/4 NPTF Air Inlet Model Number ASNS82-5-1 ASNS82-5-1-2
Installation Instruction - Torque rating Mounting Holes - 3/8 = 15-20 lb-ft Air Inlet 1/4" NPTF = 12-15lb-ft Air Inlet - 3/4 NPTF = 40-50 lb-ft
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
13
ASND10-4-1
2.0 1.8 1.6 1.4
H
100 psi
Volume (in 3)
60 50 40 30 20 10 0 5.8
Vo lum e
80 psi
3.55 DIA max. 5.71DIA 6.30 DIA Installation space needed Air Inlet 3/8-16 UNC 0.625 deep
60 psi
40 psi
20 psi
4.8
3.8
2.8
Hmax = 6.7
Force-Height Diagram
Height H (in)
Hmin = 2.8
0.79
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 45 lbs 2.5 lbs
Order Data
Type With clamped plates 1/8 NPTF air inlet Additional types on request Model Number ASND10-4-1
Installation Instruction - Torque rating Mounting holes - 3/8 NPTF = 15-20 lb-ft Air Inlet - 1/8 NPTF = 12-15 lb-ft
14
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
ASND11-4-1
Force-Height Diagram
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 45 lbs 3.3 lbs
Order Data
Type With clamped plates 1/4 Air inlet Additional types on request Model Number ASND11-4-1
Installation Instruction Torque rating Mounting Holes 3/8 = 15-20 lb-ft Air Inlet 1/4 NPTF = 12-15 lb-ft
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
15
ASND18-4-1
4.5 4.0
100 psi
Volume (in 3)
250 200
80 psi
5.55 DIA max. 8.00 DIA 8.47 DIA Installation space needed Air inlet 2 x 3/8-16 UNC 0.625 deep
60 psi
Vol um e
40 psi
20 psi
4.5
3.5
2.5
Hmax = 9.0
Force-Height Diagram
Height H (in)
Hmin = 2.8
2.75
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 45 lbs 4.8 lbs
Order Data
Type With clamped plates 3/4 NPTF air inlet 1/4 NPTF air inlet Additional types on request Model Number ASND18-4-1 ASND18-4-1-2
Installation Instruction - Torque rating Mounting holes - 3/8 NPTF = 15-20 lb-ft Air Inlet - 3/4 NPTF = 40-50 lb-ft Air Inlet - 1/4" NPTF = 12-15 lb-ft
16
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
ASND18-5-1
5.55 DIA max. 8.47 DIA 9.06 DIA Installation space needed Air inlet 2 x 3/8"-16 UNC 0.625 deep
Force-Height Diagram
2.75
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 45 lbs 5.1 lbs
Order Data
Type With clamped plates 3/4 NPTF Air inlet 1/4 NPTF Air inlet Model Number ASND18-5-1 ASND18-5-1-2
Installation Instruction Torque rating Mounting Holes 3/8 = 15-20 lb-ft Air Inlet 3/4 NPTF = 40-50 lb-ft Air Inlet 1/4 NPTF = 12-15 lb-ft
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
17
ASND18-6-1
5.0 4.5
4.0
100 psi
400
Volume (in 3)
80 psi
5.55 DIA max. 8.6 DIA 9.25 DIA Installation space needed Air Inlet 2 x 3/8-16 UNC 0.625 deep
300
60 psi
200
Vol um e
40 psi
100
20 psi
0.5 0.0
0 11 10 9 8 7 6 5 4 3
Hmax = 10.6
Force-Height Diagram
Height H (in)
Hmin = 3.0
2.75
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 45 lbs 5.1 lbs
Order Data
Type With clamped plates 3/4 NPTF air inlet 1/4 NPTF air inlet Additional types on request Model Number ASND18-6-1 ASND18-6-1-2
Installation Instructions - Torque rating Mounting holes - 3/8 = 15-20 lb-ft Air Inlet 1/4 NPTF = 12-15 lb-ft Air Inlet - 3/4 NPTF = 40-50 lb-ft
18
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
500
120 psi
ASND31-6-1
1.50
Force-Height Diagram
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 45 lbs 7 lbs
Order Data
Type With clamped plates 3/4 NPTF air inlet 1.5 inch excentrical 1/4 NPTF air inlet Model Number ASND31-6-1 ASND31-6-1-2
Installation Instructions - Torque rating Mounting holes - 3/8 = 15-20 lb-ft Air Inlet 3/4 NPTF = 40-50 lb-ft Air Inlet - 1/4 NPTF = 12-15 lb-ft
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
19
ASND31-8-1
7
1200
1000
Volume (in 3)
800
80 psi
6
H
100 psi
6.34 DIA max. 10.25 DIA 10.85 DIA Installation space needed Air Inlet 2 x 3/8-16 UNC ? 0.625 deep
600
Volu me
60 psi
400
40 psi
200
20 psi
1
1.50
0 13 11 9 7 5 3
Hmax = 12.8
Force-Height Diagram
Height H (in)
Hmin = 3.1
3.50
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 67 lbs 7.7 lbs
Order Data
Type With clamped plates 3/4 NPTF air inlet 1/4 NPTF air inlet Additional types on request Model Number ASND31-8-1 ASND31-8-1-2
Installation Instructions - Torque rating Mounting holes - 3/8 = 15-20lb-ft Air Inlet 3/4 NPTF = 40-50 lb-ft Air Inlet 1/4" NPTF = 12-15 lb-ft
20
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
ASND51-7-1
12
1000
800
Volume (in 3)
80 psi
10
100 psi
600
Vo lu
me
60 psi
8.98 DIA max. 12.80 DIA 13.39 DIA Installation space needed Air inlet 2 x 3/8" - 16 UNC 0.625 deep
400
40 psi
200
20 psi
2
2.88
12
11
10
Hmax = 12.0
Force-Height Diagram
3 H (in) Height
Hmin = 3.0
6.20
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 67 lbs 10.6 lbs
Order Data
Type With clamped plates 3/4 NPTF air inlet 2.88 inch excentrical 1/4 NPTF air inlet Model Number ASND51-7-1 ASND51-7-1-2
Installation Instruction Torque rating Mounting Holes 3/8 = 15-20 lb-ft Air Inlet 3/4 NPTF = 40-50 lb-ft Air Inlet 1/4 NPTF = 12-15 lb-ft
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
21
ASND51-8-1
12
1000
100 psi
800
Volume (in 3)
Vo lum e
80 psi
8.98 DIA max. 13.4 DIA 14.0 DIA Installation space needed Air Inlet 2 x 3/8 UNC 0.625 deep
600
60 psi
400
40 psi
200
20 psi
0 15 13 11 9 7 5 3
Hmax = 14.2
Force-Height Diagram
Height H (in)
Hmin = 3.1
6.20
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 67 lbs 11.7 lbs
Order Data
Type With clamped plates 3/4 NPTF air inlet 1/4 NPTF air inlet Model Number ASND51-8-1 ASND51-8-1-2
Installation Instruction - Torque rating Mounting holes - 3/8 = 15-20 lb-ft Air Inlet 3/4 NPTF = 40-50 lb-ft Air Inlet 1/4" NPTF = 12-15 lb-ft
22
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
2.88
10
ASND82-7-1
11.30 DIA max. 14.96 DIA 15.75 DIA Installation space needed 4 x 3/8" - 16 UNC Air inlet 0.625 deep
6.25
Force-Height Diagram
6.25
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 67 lbs 15.4 lbs
Order Data
Type With clamped plates 3/4 NPTF air inlet 3.12 inch excentrical 1/4 NPTF air inlet Model Number ASND82-7-1 ASND82-7-1-2
Installation Instruction Torque rating Mounting Holes 3/8 = 15-20 lb-ft Air Inlet 1/4 NPTF = 12-15 lb-ft Air Inlet 3/4 NPTF = 40-50 lb-ft
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
23
ASND82-10-1
20 18 16 14 12 10
H
Volume (in 3)
80 psi
100 psi
11.30 DIA max. 15.95 DIA 16.55 DIA Installation space needed Air inlet 4 x 3/8 UNC 0.625 deep
60 psi
8
40 psi
8 4
20 psi
2 0 2
Hmax = 15.4
Force-Height Diagram
Height H (in)
Hmin = 3.05
6.25
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 90 lbs 17.1 lbs
Order Data
Type With clamped plates 3/4 NPTF air inlet 1/4 NPTF air inlet Additional types on request Model Number ASND82-10-1 ASND82-10-1-2
Installation Instructions - Torque rating Mounting holes - 3/8 = 15-20 lb-ft Air Inlet 3/4 NPTF = 40-50 lb-ft Air Inlet 1/4" NPTF = 12-15 lb-ft
24
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
6.25
ASND154-8-1
30
13.87 DIA
1600
20
Vo lum e
80 psi
100 psi
Volume (in 3)
1200
15
60 psi
18 x 3/8-24 UNF
800
40 psi
10
400
20 psi
0 12 11 10 9 8 7 6 5 4 3
Hmax = 12.2
Force-Height Diagram
Height H (in)
Hmin = 3.3
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 45 lbs 19 lbs
Order Data
Type Bellow with bead rings, 1 7/8 bolts, nuts and washers Additional types on request Model Number ASND154-8-1
2000
25
1.12
15.12 DIA
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
25
ASNT51-11-1
8.98 DIA max. 12.80 DIA 13.39 DIA Installation space needed Air inlet 2 x 3/8" - 16 UNC 0.625 deep
2.88
Force-Height Diagram
6.20
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 90 lbs 18.4 lbs
Order Data
Type With Clamped Plates 3/4 NPTF Air Inlet 2.88 inch excentrical 1/4 NPTF Air Inlet Model Number ASNT51-11-1 ASNT51-11-1-2
Installation Instruction Torque rating Mounting Holes 3/8" = 15-20 lb-ft Air Inlet 1/4" NPTF = 12-15 lb-ft Air Inlet 3/4" NPTF = 40-50 lb-ft
26
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
ASNT82-12-1
18 16 14 12
80 psi
10 8 6 4 2 0
60 psi
Vo lu m e
100 psi
Volume (in 3)
11.30 DIA max. 14.96 DIA 15.94 DIA Installation space needed Air inlet 4 x 3/8 UNC 0.625 deep
40 psi
20 psi
6.25
Hmax = 21.3
Force-Height Diagram
Height H (in)
Hmin = 4.4
6.25
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 90 lbs 21 lbs
Order Data
Type With Clamped Plates 3/4 NPTF Air Inlet 3.12 inch excentrical 1/4 NPTF Air Inlet Model Number ASNT82-12-1 ASNT82-12-1-2
Installation Instruction Torque rating Mounting Holes 3/8" = 15-20 lb-ft Air Inlet 1/4" NPTF = 12-15 lb-ft Air Inlet 3/4" NPTF = 40-50 lb-ft
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
27
ASNT154-12-1
30
13.8 DIA
2500
2000
20
Vo lum e
Volume (in 3)
80 psi
25
100 psi
1500
15
60 psi
max. 18.2 DIA 20.1 DIA Installation space needed 18 x 3/8-24 UNF
1000
40 psi
10
500
20 psi
0 18 16 14 12 10 8 6 4
Hmax = 17.7
Force-Height Diagram
Height H (in)
Hmin = 4.5
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 135 lbs 21 lbs
Order Data
Type Bellow with bead rings, 1 7/8 bolts, nuts and washers Additional types on request Model Number ASNT154-12-1
28
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
1.12
15.12 DIA
ASNC2-1-1
0,40
7
Use in dotted range >2.2 in only after consultation with Numatics 120 psi
0,35
1.34 DIA
0,30
0,25
80 psi
4
60 psi
0,20
Volume [in3 ]
3
40 psi
0,15
2
20 psi
0,10
0 Hmax=2.5
2,4 2,2 2,0 1,8 1,6 1,4 1,2
0,00
Height H [in]
Hmin =1.2
Force-Height Diagram
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 5 lbs 0.5 lbs
Order Data
Type With 1/8 NPTF Air Inlet Model Number ASNC2-1-1
Installation Instruction Torque rating 5/16-18 UNC = 2-4 lb-ft 5/8-11 UNC = 8-10 lb-ft 1/8 NPTF = Handtight plus one turn.
Air inlet
0,05
m ax. 2. 34 DIA
100 psi
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
29
ASNC6-1-1
Force-Height Diagram
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 34 lbs 0.7 lbs
30
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
ASNC6-2-1
1.4
24
1.2
120 psi
1.0
Volume (in 3)
16
Vo lum e
0.8
100 psi
12
80 psi
0.6
60 psi
0.4
40 psi 20 psi
0.2
0.0
Hmax = 4.33
Force-Height Diagram
Height H (in)
Hmin = 1.5
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 0 PSI 34 lbs 0.66 lbs
20
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
31
ASNC6-3-1
0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0
5/8-11 UNC
2.4 DIA
me
H
Air Inlet
6.5
6.0
5.5
5.0
4.5
4.0
3.5
3.0
2.5
Hmax = 6.3
Force-Height Diagram
Height H (in)
Hmin = 2.6
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 5 PSI 34 lbs 0.9 lbs
Order Data
Type With 1/8" NPTF Air Inlet Brass Stud at both ends Model Number ASNC6-3-1
32
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
ASNC8-4-1
0.9 0.8 0.7
100 psi
3.35 DIA
80 70 60
Use in green range >7.5 only after consultation with Numatics
120 psi
0.6
80 psi
Volume (in3)
50 40 30 20 10 0 8 7 6 5 4
Vo lum e
0.71 Air Inlet 3/8 max. 3.82 DIA 4.6 DIA Installation space needed M8, 3/8 deep, min
60 psi
40 psi
0.2
20 psi
0.1 0.0 3
Hmax = 7.87
Force-Height Diagram
Height H (in)
Hmin = 3.75
Technical Data
Min. Pressure Return Force to Min. Height Overall Weight with Clamped Plates 13.05 PSI 101 lbs 1.15 lbs
Order Data
Type With 3/8" Air Inlet Additional types on request Model Number ASNC8-4-1
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
33
World Headquarters
USA Numatics, Incorporated
46280 Dylan Drive Novi, Michigan 48377 P: 248-596-3200 F: 248-596-3201
LT-AirBellows Rev 1/13 10M-IPC-1/09 Numatics Inc. 2009 - 2013 Numatics is registered in the United States and elsewhere
Mxico - Ascomatica SA de CV
P: 52 55 58 09 56 40 (DF y Area metropolitana) P: 01 800 000 ASCO (2726) (Interior de la Repblica) F: 52 55 58 09 56 60