Professional Documents
Culture Documents
H9MO-LM FIT
User Manual
2006.6 Disclaimer
The information contained in this document is subject to change without notice and does not represent a commitment on the part of Beijing Huahuan Electronics Co., Ltd. (Huahuan). The information in this document is believed to be accurate and reliable; however, Huahuan assumes no responsibility or liability for any errors or inaccuracies that may appear in the document.
Copyright 2006 Beijing Huahuan Electronics Co., Ltd. All rights reserved. No part of this publication may be reproduced or distributed in any form or by any means, without prior written permission of Huahuan.
Address:
No.26, Shangdi 6th Street, Haidian District, Beijing, 100085 P.R. China
TABLE OF CONTENTS
1. 2. 3. 3.1 3.2 3.3 3.4 3.5 3.6 4. 5. 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 INTRODUCTION ...........................................................................................1 TYPICAL APPLICATION .............................................................................2 APPLICATION ...............................................................................................3 STRUCTURE......................................................................................................3 FRONT PANEL ..................................................................................................4 REAR PANEL ....................................................................................................7 LCD DISPLAY AND MENU OPERATION .........................................................10 PHYSICAL DIMENSIONS .................................................................................11 INSTALLATION AND OPERATION ...................................................................11 NETWORK MANAGEMENT ......................................................................12 SPECIFICATIONS .......................................................................................16 STANDARDS ...................................................................................................16 BASIC FEATURES ...........................................................................................16 SDH FIBER OPTIC INTERFACE .......................................................................17 MANAGEMENT INTERFACE ............................................................................17 ORDERWIRE TELEPHONE ...............................................................................17 POWER ...........................................................................................................17 ENVIRONMENT ...............................................................................................18 DIMENSIONS ..................................................................................................18 WEIGHT..........................................................................................................18
Huahuan
1.
Introduction
Thank you for selecting MetroEdge-Express, the SDH based fiber optic multi-service access platform. The MetroEdge-Express is built on SDH/MSPP technology. It is aimed at providing both TDM based traditional telecom services and ever growing Ethernet based data services. There are two types of equipment in the MetroEdge-Express family, the CPE end equipment (hereafter referred to as LM, LMC, LMV, LM63 and LMFIT), and the aggregation equipment at the central office (hereafter LMX). There are three types of CPE equipment in MetroEdge-Express, show as follow. Table 1-1 Difference between CPE models Model LMFIT Feature 4 interface slots, multi-interface card selections include: DS0 64k Cross-connection DXC card, fiber optic interface card Dual STM-1 O.
As a key member of Huahuan MetroEdge-Express SDH/MSPP Product family, H9MO-LMFIT is a carrier-class, cost-effective, compact (only 1U high) SDH/MSPP platform that is designed for applications in metro and access networks to facilitate the efficient transport of traditional TDM and emerging data traffic for service providers. H9MO-LMFIT is a modularized unit with 4 universal slots, supporting different interface cards, such as STM-1 fiber optic cards, and DXC Cards The main board cross-connect capacity is 504504 VC-12s (88 VC-4s), allowing non-blocking adding/dropping services among different interfaces. It supports the hybrid transmission of SDH, and N64K services within the same equipment. With the large capacity cross-connect matrix, the H9MO-LMFIT can be configured as ADM, TM, and REG. It is suitable for multiple network topologies such as point-to-point, chain, ring, hub, and mesh networks. Features 4 General Slots, supporting a range of interface cards, including SDH, and DXC Cards. Large cross-connect matrix capacity is 504504 VC-12s (88 VC-4s) and powerful networking ability Supports 20482048 64K (full 64E1) cross-connect capacity using FDXC64 card
H9MO-LM FIT User Manual V2.6
-1-
Huahuan
LCD display for system configuration and alarm Inter-working with popular SDH/MSPP products of various vendors Suitable for 3G access network transmission Easy commissioning and maintenance High integration, compact design High reliability, low CAPEX and OPEX Operate at STM-1 SDH line rate Dual -48V DC power supply. Standard 19 inch 1 unit high box
2.
Typical Application
Fig. 2-1 depicts a typical application scenario of the MetroEdge-Express.
-2-
Huahuan
3.
Application
3.1 Structure
H9MO-LMFIT is a modularized unit with 4 universal slots, supporting different interface cards, such as STM-1 fiber optic cards,), and DXC card. The main board (show as follow) cross-connect capacity is 504504 VC-12s (88 VC-4s), allowing non-blocking adding/dropping services among different interfaces.
CARD 4
CARD 3
CARD 2
CARD 1
Up
Left
Right
Front panel
Down
4xE1 card
8xE1 card
V.35 card
Ethernet card
Ethernet card
F155-DO
H9MO-LM/FIT.SYS
-3-
Huahuan
FDXC64
504504 VC12 SNMP or Q3 10Base-T and RS232 RS485 Standard socket RJ11 Supported 1U: 440 44 230 (mm) -48V DC -dual power supply Consumption 15 w 5C45C 90 % 3.5 kg
EOW interface LCD Display Physical Dimension Supply Power Consumption Environment Weight Temperature Humidity
SNMP
FIT
CARD
1234
OW
Hua huan
Phone Jack
Power indication
Card status
RS232/485 SV socket
The LEDs
The LEDs on the front panel indicates the operation status and alarms of the H9MO-LM FIT unit. They are listed in Table 3.2-1. Table 3.2-1
-4-
Huahuan
LED PWR SYS OW Color Green Green Green Definition General power indicator operation status
Explanation On: Normal Off: Power Off / Failure On or off: System abnormal or system initialization. Blink: Normal operation call On: calling or called order Off: No order telephone
Orderwire telephone indication Alarms (alarm trigger set by software) Yello Blink: Deferred alarm D Deferred alarm. w Off: Normal Alarm Blink: Prompt alarm, Prompt alarm / Loss of signal On: Loss of incoming STM-1 P Red indicator sig. Off: Normal Card slots Off: No card in the slot CARD Green Operation status of the 4 cards Green: card in the slot is normal 1~4 /Red Red: card in the slot is abnormal RJ45 SNMP port (10Base-T supported) On: Link LEDs Green link activity indicator Blink: Data On the Off: Inactive RJ45 On: full duplex Yello jack Duplex indicator Off: half duplex w Blink: collision
SV Interface:
There are 2 types of management interfaces, Q Interface and F Interface on H9MO-LM FIT front panel. Q Interface (Ethernet Interface): SNMP port, RJ45, SNMP protocol, 10Base-T Ethernet MDI. Default IP address: 192.192.4.2 (can be set by CONSOLE port). The RJ45 is used to connect to a management workstation running network management software, such as the H7GMSW. It is a MDI 10Base-T port, and can be connected to the LAN using standard Ethernet cable like any other computer. F Interface: CONSOLE port (RS232 and RS485), Connector: RJ45 socket. Software version 1.2.1 or above delete some functions of RS232 interface, leaving getconf, getinfo, setaddr, exit, help command and add Telnet query functionSoftware version 1.2.1 or above adopt Telnet instead of F interface and delete RS232 interface, RS232 Interface__Pin Definition: 6 Rx; 3 Tx; 5 GND, Port Setting: 9600, 8, N, 1.
H9MO-LM FIT User Manual V2.6
-5-
Huahuan
RS485 Interface__Default Band Rate: 2400; 1200, 1800, 2400, 4800, 9600, 19200, 38400 selectable; TABS protocol; Port Setting: 8, 1, Odd parity. For cascade SV. UserName: admin. Password: admin. Default IP address: 192.192.4.2 (can be set by CONSOLE port). Abbreviation word__OS: F155-O, OD: F155-DO, E4: F4xE1, E8: F8xE1, D2: FFE201, D4: FFE404, VI: F2xV35. Table 3.2-2. RJ45 socket of RS232 and RS485 SV port(Label: CONSOLE) 1 2 3 Pin No. 485RxN 485RxP 232TxD Definition Note RS485 RS485 RS232
Rx Rx+ Tx
4
Sel
5
GND
6
232RxD RS232 Rx
7
485TxN RS485 Tx
8
485TxP RS485 Tx+
Tx and Rx for H9MO-LM FIT Table 3.2-3. RS232 SV cable example Pin No. of RJ45 head (Male) Pin No. of DB9hole 3Tx 2Rx 6Rx 3Tx 5Gnd 5Gnd Table 3.2-4. RS485 SV cable example Pin No. of RJ45 head (Male) Pin No. of DB9hole 1RxN 2TxN 2RxP 1TxP 7TxN 4RxN 8TxP 3RxP Pin 4 and Pin5 connected
The console port is a RS232 serial port for command line access to the internal microcontroller system. [Software version 1.2.1 or above adopt Telnet instead of F interface and delete RS232 interface]. The console port can be connected to a VT100 dummy terminal, or a PC running terminal emulation program such as the windows HyperTerminal. The console port protocol is 9600 baud, 8 data bits, 1 stop bit, no parity, no flow control. The main function of the console is to modify hardware parameters such as the node address, etc. It can also be used to check operational status, or issue simple commands. The command input is not case sensitive. Console access is password protected. Default username is admin, and default password is hhpostern or admin. The user can change the user name and password. If no key stroke is performed in 3 minutes, the system will automatically log off.
Orderwire:
The RJ11 port (label: OW) at the right is the phone jack for orderwire telephone. This telephone is also used as a hand held input device for LCD menu selection.
-6H9MO-LM FIT User Manual V1.0
Huahuan
LCD:
LCD Display and Menu Operation show in section 3.4.
4-DIP Switches:
There are 4 dip switches on the front panel. They are reservation.
220V Power in
AC 220V 50Hz 1A
II
ALM1 ALM2 Tx 1 Rx Tx 2 Rx
ALM
IN OUT IN OUTIN OUT IN OUT 1 2 3 4 ETH-1 ETH-2
CARD-1
CARD-2
CARD-3
CARD-4
- +
Optical Sockets
E1 Sockets
Alarm Socket
Fig. 3.3-1 H9MO-LM FIT Rear Panel Table 3.3-1 LM FIT Rear panel LED definition Labe l
ALM ALM-1 ALM-2
Description
Note
Green Yellow
Green Yellow
Red
ALM-n
Red
F155-O/F155-DO(H9MO-LMF.OLT) F155-O STM1 optical port alarm On: loss of optical signal F155-DO Wink: receive bit error Off: normal operation FFE201 (H9MO-LMF.ETH) Link indicator. LEDs On the On: Link, Off: Inactive RJ45 jack Duplex indicator. On: full duplex, Off: half duplex, Blink: collision FFE404 (H9MO-LMF.ETH) Activity indicator. LEDs On the Blink: Data, Off: Inactive RJ45 jack Speed indicator. On: 100M, Off: 10M F2xV35(H9MO-LMF.V35) Two V35 signals indicators F2xV35 On: V35 loss, Off: receive V35 normal F4xE1(H9MO-LMF.E1) nth E1 port condition indication On: loss of incoming HDB3 signal(LOS) F4xE1
H9MO-LM FIT User Manual V2.6
-7-
Huahuan
Description Note
Labe l
(n=1~4)
Color
F155-O/F155-DO(H9MO-LMF.OLT) Fast wink(~0.5s): AIS or HDB3 code violation Slow wink(~1s): the port is in loop-back mode Off: normal operation or alarm masked
Power Inputs:
The H9MO-LM FIT can be powered either with -48VDC or ~220VAC supply. The flip switch selects the power input. When flipped up, -48VDC is selected, and ~220VAC is selected with switch flipped down. The middle position switches the power off.. Use standard AC power cord supplied with the unit to connect to the ~220VAC power supply. Use power outlet with secure earth connection to avoid danger of electric shock. -48VDC power supply is connected to the LM through the PWR-IN socket, a plug is supplied for the socket. Connect power wires to the plug according to Fig.3.3-2. Insert the prepared wire end into the hole on the left end of the plug, tighten the screw to securely fix the wire to the plug. After fixing all the wires, push the plug into the socket.
- 48V 0V Ear t h
Grounding:
Grounding screw on the rear panel of a H9MO-LM FIT is used to connect the chassis to the protective ground.
CGND
-8-
Huahuan
Optical Port:
Default fiber optic interface is the dual fiber SC socket type, with nominal wavelength of 1310nm and link range of under 40km. Tx denotes output port, and Rx the input port. With single fiber option, only one fiber socket is used for both input and output. Single fiber module transmits and receives optical signals in different wavelengths. Only transmit wavelength is specified. Usually, the single fiber version LIU on LMX transmits at 1310nm, and single fiber LM FIT transmits at 1550nm. Note that when two single fiber LM FITs are to be linked point-to-point, they must have different transmit wavelength.
F155-O
Tx 1 Rx
Fig. 3.3-4 Sketch map of F155-DO and F155-D Table 3.3-3 Slot Line Clock Corresponding relationship of CARD and line clock CARD1 0 1 CARD2 2 3 CARD3 4 5 CARD4 6 7
How to set clock by network management software? F4E1 card inserted in the second universal slot of H9MO-LMFIT provide the first and second E1s for output clock A and B. 1,In NMS config management select 1 &2 E1 channels 2. In NMS Backboard Clock option, prior clock select Line 2 clock Note : F4E1 line clock corresponds 2E1 interfaces F8E1 line clock corresponds 4E1 interfaces
FDXC64 card: FDXC64 card supports 64kbps time slot cross-connection matrix which can fulfill 30
H9MO-LM FIT User Manual V2.6
-9-
Huahuan
or 31 64kbps (depend on the 16th usage) time slot cross-connection. DXC card does not have output interfaces. Embedded software of FIT SV V1.3.3 version or above and NMS H7GMSW of V7.5.32 or above support FDXC64 card
Huahuan
Alarm Menu
Address Info Set Mask Clear Mask System Board CARD slot 1 CARD slot 2 CARD slot 3
Alarm Indication
Detailed Alarms
NOTE: System Board info include 4-digit Order telephone number (PHN)
- 10 -
Huahuan
Fig. 3.4-2
230 m m
31. 8 m m
H9MO-LM
PW R SYS ALARM CAR D D P O W1 2 3 4
C O N SO LE
SN M P 1234
O W
H uahuan
FI T
465m m
Fig. 3.5-1
-11-
Huahuan
4.
Network Management
An access network built with MetroEdge-Express product can be managed with the network management software package H7GMSW. The H7GMSW is a GUI based network element management software package. It supports both SNMP and TABS protocols. At the physical layer, SNMP uses Ethernet, while TABS uses RS485 to connect to the monitored equipment. H9MO-LMFIT supports SNMP and TABS. The software models the monitored network in 3 different perspectives: the network/area view, the site/element view, and the equipment/card view. In the network/area view, icons represent equipment sites are connected with lines representing fiber optic connections, forming networks. Double click on a site icon enters into the site/element view. Installed equipment in the site is graphically represented. Double click on the equipment or cards inside the equipment brings up the equipment/card window. Alarms will be indicated at any level by flashing the respective icons, and detailed defects are shown at the equipment/card window. Control on individual equipment or card is also done at that window. Control at the network level, such as channel allocation, is done at the network/area window. How to get the IP address of the device? You can get the IP address of H9MO-LMFIT by dip switch. Push down the first dip switch and you can see the IP address is displayed in the LCD. How to change the IP address of the device? Login in telnet and you can change the IP address of H9MO-LMFIT.
Login in telnet. Both the user name and password are admin.
- 12 -
Huahuan
-13-
Huahuan
Input #setaddr and then you can change your IP address. Input 192.192.4.3 e.g..
- 14 -
Huahuan
-15-
Huahuan
The detailed description of the software should refer to its user manual and online help. Here, only brief introduction is presented.
5.
Specifications
H9MO-LM FIT confirms to the standards listed in table6-1. Table 5-1 Related Standards
5.1 Standards
Item STM-1 Optical E1 Data --- Ethernet Data --- V35 Timing 2Mbit/s 2MHz SDH Network Topology Network Management Protection
Standard
G.707, G.957 G.703 IEEE 802.3100Base-Tx V.35/V.36 G.823 G.813, G.825 G.783, G.803 G.805 G.958 G.744, G.784 ,G.831, Q.811, Q.812, M.3100, M.3000 G.841, G.842
Timing mode: line clock or internal oscillation Service card: Single/Dual STM-1 optical interface card, 4E1 interface card (75), 8E1 interface card (75 or 120), 2FE interface card (2 FEs over a single virtual concatenation channel, (1~46)VC12), 4FE interface card (4 FE interface over 4 independent virtual concatenation channels, (1~46)VC12), 2V.35 framed interface card (N64k). Cross-connect embedded: 504504 VC12 cross-connetct capability
- 16 -
Line Code Scrambled NRZ SDH interface: 1 to 8 STM-1 optical interfaces Connector: SC or FC Spec.: S-1.1, L-1.1, L-1.2 Single fiber bi-directional interface can be optionally supported. 5.4 Management Interface Q Interface (Ethernet Interface)RJ45, SNMP protocol, 10Base-T Ethernet MDI F Interface: CONSOLE port (RS232/RS485) RS232 Interface Standard: RS232 Connector: DB9F Pin Definition: 2 Rx; 3 Tx; 5 GND Port Setting: 9600, 8, N, 1 RS485 Interface Default Band Rate: 2400; 1200, 1800, 2400, 4800, 9600, 19200, 38400 selectable TABS protocol Port Setting: 8, 1, Odd parity 5.5 Orderwire Telephone RJ11 socket, DTMF. Phone number: #NNNN. 5.6 Power Voltage: -48V (-38V-62V) Power Consumption: 15W (full system)
-17-
Huahuan
5.8 Dimensions
1U 19(mm): 440 44 230
5.9 Weight
3.5(kg)
- 18 -