POWER SYSTEM PROTECTION & DIAGNOSTICS

DEVICE SETTINGS RELAYS TESTING REVIEW OF POWER SYSTEM SCENARIOS

Relay Testing Relay Coordination Panel Commissioning


Our Relationship with Protection & Diagnostics List of Services Offered: Design Relay Settings ? Power System Simulation ? Relay Coordination ? MV/LV Panel Commissioning ? MV/LV Testing ? Meter Testing ? Transducer Testing ? Protection Trainings ? Primary Injection ? Secondary Injection ? Protection CT Testing ? Upgradation of relays
? Protection ? Power System

Setting Calculations Relay Commissioning Protection Training

Prescon offers full range of Power System Protection Services. Starting from Consultancy, Design, Prescon now incorporates relay testing including acceptance testing, commissioning testing and End-to-End testing services in its portfolio of ever inreasing Asset management solutions. Prescon has experienced and trained professionals, ETAP - Power System Design Suite and Doble F6150 Relay Testing Sets in addition to presence of a large library including various IEC and IEEE standards. Prescon can assist you in replacement of relays, installation and commissioning of complete panels and schemes, setting reviews and calculations. We are also proudly offering services for upgradation of protection schemes based on latest Numercial protection relays from any manufacturer of your choice. In addition to above, we are providing Training services to our clients all over Pakistan and abroad. We can study your system and make a specific training program of your desire. Write to us at services@theprescon.com or info@theprescon.com for general information.

If you cannot find services you seek in the above list, please do not hesitate to contact us.

Precision Engg Services & Consultancy co.

. . S O L U T I O N S

info@theprescon.com

Http://www.theprescon.com

List of IEEE Device and Source Requirements for F6150 Family of Power System Simulators
The F6150 Simulators are fully capable of testing all types of protective relays, including these IEEE relay types. In addition, using the Power System Model, P ProTest Macro, any relay may be tested under true power system conditions, regardless of it measurement function. IEEE Device Number . . . . .Relay Type . . . . . . . . . . . . . . . . . . . . . . . . Sources 2 . . . . . . . . . Time Delay and Starting . . . . . . . . . . . . . . 1 Vdc, 1 Idc . . . . . . . . . . . . . . . . . . . . . . . 1 Vac, 1 Iac 21 . . . . . . . . D . istance 1 F 21 . . . . . . . . Distance, 3 F wye Voltage and Current . . 3 Vac, 3 Iac (open-delta) . . . . . . . . . . . . 2 Vac, 2 Iac 21 . . . . . . . . .Distance 3 F 21G . . . . . . .Gr round Distance . . . . . . . . . . . . . . . . . . 3 Vac, 1 Iac 24 . . . . . . . . .Volts/Hertz . . . . . . . . . . . . . . . . . . . . . . . . 1 Vac 25/25G . . . . .Auto-Synchronizing and synch check. . . . 2 Vac 27/59 . . . . . .AC/DC Under/Overvoltage . . . . . . . . . . . . 1 Vac or 1 Vdc . . . . . . . . . . . . . . . . 1 Vac, 1 Vac 32 . . . . . . . . .Directional Power 1F 32 . . . . . . . . .Dir rectional Power 3F (open delta ...... 2 Vac, 2 Iac voltages, open wye current) 37/76 . . . . . . .DC Undercurrent/Overcurrent . . . . . . . . . 1 Idc 40 . . . . . . . . .Loss of Field . . . . . . . . . . . . . . . . . . . . . . 1 Vac, 1 Iac or 1 Vdc, 1 Idc 46 . . . . . . . . .Phase Balance . . . . . . . . . . . . . . . . . . . . .3 Iac 46N . . . . . . .Negative Sequence Overcurrent . . . . . . . 3 Iac 47 . . . . . . . . .Phase Seq. Voltage (open-delta) . . . . . . . . 2 Vac 50 . . . . . . . . .Instantaneous Overcurrent (up to 90A . . . 1 Iac Continuous, 180A 1.5 Seconds Max.) 51 . . . . . . . . .Time Overcurrent (up to 90A . . . . . . . . . . 1 Iac Continuous, 180A for 1.5 Seconds Max.) : : 3 Vac, 3 lac 1 Vac, Iac; 3 F 67 . . . . . Directional Overcurrent . . . . . . . . . . . 1.F 67N . . . . . . .Ground Directional Overcurrent. . . . . . . . 1 Vac, 1 Iac 79 . . . . . . . . .AC Reclosing . . . . . . . . . . . . . . . . . . . . . . 2 Vac, 1 Logic 81. . . . . . . . .Frequency . . . . . . . . . . . . . . . . . . . . . . . . . 1 Vac or 3 Vac . C Reclosing . . . . . . . . . . . . . . . . . . . . . . 1 Vdc, 1 Logic 82 . . . . . . . . D 85 . . . . . . . . .Carrier or Pilot Wire . . . . . . . . . . . . . . . . 1 Idc, 1 Vdc or Iac 86 . . . . . . . . .Lock-out . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Vdc 2 Iac F , 87 . . . . . . . . .Differential: . . . . . . . . . . . . . . . . . . . . . . . . 1 , 6 Iac 87 . . . . . . . . .Differential: . . . . . . . . . . . . . . . . . . . . . . . . 3F 94 . . . . . . . . .Tripping . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Vdc or 1 Idc