Margin on flow

Margin on Head
Flow

20
44

m3/hr
M3/sec
mmwc
Nm3/hr
TEMPERATURE deg c
factor
Power consumption
PA Fan Selection
Flow in nm3/hr
Margin
Flow in tph with 10% margin
Inlet temp in deg C

20
30
72069 86482.8
20.019167
24.023
765
994.5
63879.341 76655.21
35
1.1282051

108104 129724.8
30.02889 36.03467
1428 2056.32
95819.45 114983.3
35
1.128205

Operating Design
SA Fan Selection
Operating Design
ID Fan Selection
Operating
95819.45 114983.3 Flow in nm3/hr
63879.34 76655.21 Flow in nm3/hr
183122
0
0 Margin
0
0 Margin
0
95819.45 114983.3 Flow in tph with 10% margin
63879.34 76655.21 Flow in tph with 10% margin183122
35
50 Inlet temp in deg C
35
50 Inlet temp in deg C
145

Flow in M3 / sec
Flow in M3 / hr
Fan head in mmwc
ID Fan Power Calculation
Fan Efficiency
Motor Efficiency
Margin
Power rated in kW
Std Motor

30.02889 37.78959 Flow in M3 / sec


108104 136042.5 Flow in M3 / hr
1428 2056.32 Fan head in mmwc

20.019166 25.19295 Flow in M3 / sec


72068.999 90694.63 Flow in M3 / hr
765
994.5 Fan head in mmwc

77.884611
280384.6
435

ID Fan Power Calculation


ID Fan Power Calculation
0.93
0.93 Fan Efficiency
0.75
0.93 Fan Efficiency
0.75
0.85
0.85 Motor Efficiency
0.95
0.85 Motor Efficiency
0.95
0.9
0.9 Margin
0.9
0.9 Margin
0.9
590.9121 1070.824 Power rated in kW
234.1423 345.2544 Power rated in kW 517.98044
37
37 Std Motor
37
37 Std Motor
37
350

Boiler Feed Pump Selection


Actual Flow in TPH
Margin
Flow in tph with 10% margin
Boiler Steam Pr in Kscg
Margin in head
Loss in Kscg

20
30
280385
77.884722
435
183122.26
145
1.5311355

opera design
75
82.5
0.01
0.01
75.75
83.325
128
140.8
0.1
0.1
4
4

76.5

Head in kscg
Head in mwc
Pump Efficiency
Motor Efficiency
Margin
Power rated in kW
Std Motor in kW

145.2
159.28
1544.681 1694.468
0.93
0.93
0.8
0.8
0.9
0.9
475.8864 574.2362
130
450

336462
93.461667
565.5
219746.71

25
25
600
750
0.166667 0.208333
4590
5737.5
531.8182 633.9009
35
50
1.128205 1.18315

Design
219746.7
0
219746.7
150

J seal Fan Selection operating design


Flow in nm3/hr
531.8182
633
Margin
0
0
Flow in tph with 10% margin
531.8182
633
Inlet temp in deg C
35
50

94.579624

Flow in M3 / sec

340486.65
565.5

Flow in M3 / hr
Fan head in mmwc

0.93
0.85
0.9
737.0308
37
750

0.166667 0.208037
600 748.9341
4590
5737.5

ID Fan Power Calculation


Fan Efficiency
0.75
0.93
Motor Efficiency
0.95
0.85
Margin
0.9
0.9
Power rated in kW 11.69591 16.44823
Std Motor
37
37
18.5

Margin on flow
Margin on Head
Flow

TEMPERATURE
factor
Power consumption

20
44
m3/hr
M3/sec
mmwc
Nm3/hr
deg c

PA Fan Selection
Flow in nm3/hr
Margin
Flow in tph with 10% margin
Inlet temp in deg C

20
30
72069 86482.8
20.019167
24.023
765
994.5
63879.341 76655.21
35
1.1282051

108104 129724.8
30.02889 36.03467
1428 2056.32
95819.45 114983.3
35
1.128205

Operating
27243
0
27243
45

Design
31330
0
31330
50

SA Fan Selection
Operating
Flow in nm3/hr
18162
Margin
0
Flow in tph with 10% margin 18162
Inlet temp in deg C
45

Design
20886
0
20886
50

Flow in M3 / sec

8.81489 10.29669 Flow in M3 / sec

5.8765934 6.864243

Flow in M3 / hr
Fan head in mmwc

31733.6
1250

21155.736 24711.27
950
1093

ID Fan Power Calculation


Fan Efficiency
Motor Efficiency
Margin
Power rated in kW
Std Motor

37068.1 Flow in M3 / hr
1438 Fan head in mmwc

ID Fan Power Calculation


0.93
0.93 Fan Efficiency
0.75
0.93
0.85
0.85 Motor Efficiency
0.95
0.85
0.9
0.9 Margin
0.9
0.9
151.8387 204.0385 Power rated in kW
85.353572 103.3876
37
37 Std Motor
37
37
350

Boiler Feed Pump Selection


Actual Flow in TPH
Margin
Flow in tph with 10% margin
Boiler Steam Pr in Kscg
Margin in head
Loss in Kscg
Head in kscg
Head in mwc
Pump Efficiency
Motor Efficiency
Margin
Power rated in kW
Std Motor in kW

opera design
73
80.3
0.01
0.01
73.73
81.103
87
95.7
0.1
0.1
4
4
100.1
109.67
1064.894 1166.702
0.93
0.93
0.8
0.8
0.9
0.9
319.3246 384.8387
130
450

76.5

37.5

425.33333
337.5

20
30
280385
336462
77.884722 93.461667
435
565.5
183122.26 219746.71
145
1.5311355

ID Fan Selection
Operating
Flow in nm3/hr
51338
Margin
0
Flow in tph with 10% margin 51338
Inlet temp in deg C
145

Design
59039
0
59039
150

25
25
600
750
0.166667 0.208333
4590
5737.5
531.8182 633.9009
35
50
1.128205 1.18315

J seal Fan Selection operating design


Flow in nm3/hr
531.8182
633
Margin
0
0
Flow in tph with 10% margin
531.8182
633
Inlet temp in deg C
35
50

Flow in M3 / sec

21.834843 25.410559

Flow in M3 / sec

Flow in M3 / hr
Fan head in mmwc

78605.436 91478.011
450
518

Flow in M3 / hr
Fan head in mmwc

ID Fan Power Calculation


Fan Efficiency
0.75
0.93
Motor Efficiency
0.95
0.85
Margin
0.9
0.9
Power rated in kW 150.22252 181.38418
Std Motor
37
37
750

75.75
319

0.166667 0.208037
600 748.9341
4590
5737.5

ID Fan Power Calculation


Fan Efficiency
0.75
0.93
Motor Efficiency
0.95
0.85
Margin
0.9
0.9
Power rated in kW
11.69591 16.44823
Std Motor
37
37
18.5

150TPH TG Boiler
Sl. No
1
2
3
4
5
6
7
8
9

Description
BFWP
PA
SA
ID
Drum Extractor
Screw Conveyor
Stroker Hydraulic Drive
HP Dosing Pump
LP Dosing Pump

Qty
3 (2W+1S)
2
2
2
6
6
2
2
2

150TPH TG Boiler
Sl. No
1
2
3
4
5
6
7
8
9

Description
BFWP
PA
SA
ID
Drum Extractor
Screw Conveyor
Stroker Hydraulic Drive
HP Dosing Pump
LP Dosing Pump

Qty
3 (2W+1S)
2
2
2
6
6
2
2
2

150TPH TG Boiler
Sl. No
1
2
3

Description
BFWP (VFD)
PA (VFD)
SA (VFD)

Qty
3 (2W+1S)
2
2

4
5
6
7
8
9

ID (VFD)
Drum Extractor (VFD)
Screw Conveyor (VFD)
Stroker Hydraulic Drive (DOL)
HP Dosing Pump (DOL)
LP Dosing Pump (DOL)

2
6
6
2
2
2

ler
Power Consumption in
kw
674
89
189
274
37.5
27.5
5
1.1
0.37

ler
Power Consumption in
kw
674
89
189
274
37.5
27.5
5
1.1
0.37
648.5

ler
Power Consumption in
kw
1685
222.5
472.5

685
93.75
68.75
35
7.7
2.59
3272.79