Professional Documents
Culture Documents
Feature
CCD camera system is applied and 2 pcs of camera can be connected to 1 pce of controller Analog output can be displayed with 7 segment LED on the controller. Current analog value can be read directly. Waveform of camera can be displayed with maintenance mode by connecting PC. It is possible to check light-reception level or influence by disturbance light.
Specifications
Sensor head(Camera) Model No. Power source Detectable object Min.detectable objects Light-receiving element Detection view Resolution Scanning cycle Ambient temperature Ambient humidity Cooling water Air for dustproof(option) Hood Protective structure
VMH-KZ20 Suuplied from controller Hot metal with 750 degrees C or more Detection view 1/2,048 CCD image sensor with 2,048 bits 700mm (distance)m Detection view 1/2,048 3msec/6msec(changeover) -5 to +55 degrees C, -5 to +80 degrees C when cooling 45 to 85%RH(not icing, not condensing) Pressure: 100 to 200kPa, withstand pressure: 500kPa, amount: 4 to 6lit/min, temperature: 35 degrees C or less, quality: industrial clean water Withstand pressure: 1MPa, amount: 100lit/min, quality: industrial clean air(available only when using air-purge) Detachable on-air dust-purge hood IP64(IEC standard)
Case materials Aluminum casting Weight Approx. 3.5kg * Wide area type VMH-KZ30 is available. Controller Model No. Power source Current consumption Analog output
Max. -10 to +10VDC 0.1% 10mA(output impedance 100) 2pcs(each sensor head) Object1C photo-mos relay, VoffAC/DC 250V, loAC/DC 100mA 2pcs(each Output existing(DETECTION) camera)
Light-receiving amount lowering(LOW) Signalexisting(SIGNAL) Device trouble(RUN) Light-receiving amount lowering(LOW) Input Response time Connection
Photo-coupler, VceDC 80V, lcDC 50mA 1pce(OR output for each camera)
1a photo-mos relay, VoffAC/DC 250V, loDC 250V, loAC/DC 100mA 1pce(OR output for each camera)
Display
Ambient temperature Ambient humidity Insulation resistance Withstand voltage Vibration resistance Impact resistance Case materials Weight
Camera sensitivity changeover, photo-coupler 1 pce(common use for camera 1 & 2) 24VDC 50mA or less 6msec/12msec or less(changeover) For communication: 9 pins D-sub connector For sensor head: exclusive cable 7-segment LED, 4 digits 2(analog output per camera) Red LED 5 points(object-existing 2 points(each camera), signalexisting, light-receiving amount lowering, device trouble, each 1 point(OR per camera) PC screen(analog, waveform, setting state etc.) available only when connecting PC -10 to +50 degrees C 45 to 85%RH(not icing,not condensing) 20M or more(between power/output contact and case by 500V megger) AC1,500V, 1min.(between power/output contact and case) Double amplitude 1.5mm, 10 to 55Hz, each 2 hour in X, Y and Z directions 500m/s2, each 10 times in X, Y and Z directions Steel plate(SECC) Approx. 2kg
External dimension
Sensor head
Controller
Feature
Setting of sensitivity adjustment against temperature of detecting material had not been obvious. However this equipment displays reception level lamps in every twice using linear characteristic relationship between temperature and analog output voltage(8 levels). Operation setting can be made with level display or analog voltage. Also, there are three ranges, L/M/H as detection temperature changeover switch. Any parts such as slits etc. aren't required for 350 to 1,200 degrees C. It is epoch-making HMD that operation point setting is possible with detecting condition before operation. This device doesn't specify power source. It is capable of being used within the scope of 100 to 240VAC. Water-cooling or air-purge isn't required for sensor head because non-air dust purge hood is applied. Warning output is provided. We have wide variety of sensor head. Refer to data sheets of head.
Specifications
PRV-10A*1 FHM-201(Basic type), FHM-203(Narrow directivity type), FHM-201-8WA (Wide directivity type) Fiber unit *2: FHV-321(2m), FHV-351(5m), FHV-411(10m) Heated material with 360 to 1,200 degrees C 5m(Different depending on the size or temperature of detectable objects against detection range, or fiber length*3) 100 to 240VAC(+10%, -15%, 50/60Hz) Amplifier: Sensor head: Model No.
Detectable objects Detecting distance Power source Control output Warning output
1C relay contact(250VAC 3A, COS=1), Photo-coupler(Max. 120V, 100mA) Amplifier:-10 degrees C to +55 degrees C Ambient temperature Sensor head/Fiber unit:-10 degrees C to +200 degrees C 45 to 85%RH(Not icing) Ambient humidity *1 PRV-10B with communication function and PRV-10C with detection temperature outside changeover function are also available. *2 3m, 15m and 20m type are also available. *3 Ask us in details.
External dimension
Connection
Control output(Changeover by inner switch) Operating mode Light-ON Pin No. of connector. 5-6 9-10 Power-OFF state OFF OPEN When lightON CLOSE Power-ON entering state When lightOFF OPEN interrupting Warning output Pin No. of connector. 7-8 12-13 Power-OFF state OFF OPEN When ON CLOSE Power-ON normal state When OFF OPEN troubled
PAGE TOP