You are on page 1of 13

Air Conditioning

Technical Data
4-way blow ceiling mounted cassette

EEDEN13-131

ACQ-B

Indoor Unit 4-way blow ceiling mounted cassette ACQ-B

TABLE OF CONTENTS ACQ-B

1 2

Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2 3 3 4 5

3 4

Safety device settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


Safety Device Settings

...... .......... .......... .......... .......... . 5 6 6 7

Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensional Drawings with Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5 6 7

Piping diagrams
Piping Diagrams

........... .......... .......... .......... .......... . 8

. ........... .......... .......... .......... .......... . 8 ........... .......... .......... .......... .......... . 9 ..... .......... .......... .......... . 9 10

Wiring diagrams

Wiring Diagrams - Single Phase Sound Pressure Spectrum

Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Split - Sky Air Indoor Unit

Indoor Unit 4-way blow ceiling mounted cassette ACQ-B

1
tk iSw no U l - b r t oy Bi oa - dlwQ np- C ISA4

Features
Ideal solution for shops, restaurants or offices requiring maximum floor space for furniture, decorations and fittings Blends unobtrusively with any interior dcor: only the suction and discharge grilles are visible Air can be discharged in any of 4 directions Air filter removes airborne dust particles to ensure a steady supply of clean air Easy installation and maintenance

1
1

Split - Sky Air Indoor Unit

Indoor Unit 4-way blow ceiling mounted cassette ACQ-B

Specifications
ACQ71B A CQ10 0B ACQ1 25B

2-1 Technical Specifications


Power input - 50Hz Casing Dimensions Cooling Heating Material Unit Packed unit Weight Packing Decor ation panel Unit Packed unit Material Weight Colour Dimensions Weight Length Rows Fin pitch Face area Stages Tube type Tube material Tube diameter Fin Type Quantity Air flow rate Nom. Nom. Height/Width/ Depth Height/Width/ Depth kW kW mm mm kg kg kg Height/Width/ Depth mm kg mm Quantity mm m Quantity

117 117 265/820/820 306/916/916 31 34

99 99 G alvanised steel 300/820/820 335/916/916 39 42 EPS / Corrugated board 3 White 82/990/990 4

142 142

3 1
2

Heat exchanger

1,772 3 1.41 370,000 10 Inner Gr oove Copper 7 Slit fin Hydrophilic Turbo fan 1 29.2 1,030 24.4 860 21.0 740 17.6 620 29.2 1,030 24.4 860 21.0 740 17.6 620 0 0 0

1,831

460,000 12

mm Type Treatment

Fan

Cooling High Nom. Low Silent operati on Heating High Nom. Low Silent operati on

m/min cfm m/min cfm m/min cfm m/min cfm m/min cfm m/min cfm m/min cfm m/min cfm Pa Pa Pa

24.4 860 20.5 725 17.6 620 15.0 530 24.4 860 20.5 725 17.6 620 15.0 530

34.0 1,200 29.2 1,030 26.3 930 22.1 780 34.0 1,200 29.2 1,030 26.3 930 22.1 780

External static pressure

High Nom. Low

Split - Sky Air Indoor Unit

Indoor Unit 4-way blow ceiling mounted cassette ACQ-B

Specifications
ACQ71B ACQ1 00B ACQ125B

2-1 Technical Specifications


Fan motor Quantity Model Index of Protection Insulation grade Poles Drive Speed

1
2

MCK28E-502-HT 20

1 MCK40E 70W 310VDC 40 B 8 Dir ect drive 4 + silent + auto 680/580/510/435

MCK50E 100W 310VDC

Steps Cooling High/ Mediu m/Low/ Silent oper ati on Heating High/ Mediu m/Low/ Silent oper ati on Cooling Heating High/Nom./Low/ Quiet High/Nom./Low/ Quiet High/Nom./Low/ Silent oper ation Super high/High/ Nom./Low/Silent operation Type/OD Type/OD

r pm

610/520/460/410

780/680/620/530

r pm

610/520/460/410

680/580/510/435

780/680/620/530

Phase x Voltage Full load amps (FLA) Sound power level Cooling Heating Sound pressure level Cooling Heating

V A A dBA dBA dBA dBA

0.53 0.53 54/50/48/47 54/50/48/47 41/38/35/32 - /41/38/35/32

1 x 230V 0.83 0.83 56/54/53/52 56/54/53/52 44/41/38/36 -/44/41/38/36

1.29 1.29 60/56/54/53 60/56/54/53 47/44/43/41 -/47/44/43/41

Refr iger ant Piping connections

Type Liquid Gas Drain Heat insulation

mm mm

Temperature control Air direction control Air filter

Type

R- 410A Flar e connection/9.52 Flare connection/15.88 19.05 Both liquid and gas pipes Microcomputer control 4 dir ections, vertical Removable / washable

Standard Accessor ies : Cover lock grill; Standard Accessor ies : Battery; Standard Accessor ies : Wireless r emote control; Standard Accessor ies : Washer; Standard Accessor ies : Screws; Standard Accessor ies : Operation manual; Standard Accessor ies : Installation manual;

2-2 Electrical Specifications


Power supply Name Phase Frequency Voltage Min. Max. For power supply

ACQ71B

ACQ1 00B

ACQ125B

Voltage r ange Wiring connections 50Hz

Hz V % % Q uantity Remark

V1 1~ 50 220-240 -10 10 3 4 for interunit wiring (earth wire included)

Split - Sky Air Indoor Unit

Indoor Unit 4-way blow ceiling mounted cassette ACQ-B

3
3-1

Safety device settings


Safety Device Settings

3 1
3

Split - Sky Air Indoor Unit

Indoor Unit 4-way blow ceiling mounted cassette ACQ-B

4
4-1

Dimensional drawings
Dimensional Drawings

1
4

Split - Sky Air Indoor Unit

Indoor Unit 4-way blow ceiling mounted cassette ACQ-B

4
4-2

Dimensional drawings
Dimensional Drawings with Accessories

3 1
4

Split - Sky Air Indoor Unit

Indoor Unit 4-way blow ceiling mounted cassette ACQ-B

5
5-1

Piping diagrams
Piping Diagrams

1
5

Split - Sky Air Indoor Unit

Indoor Unit 4-way blow ceiling mounted cassette ACQ-B

6
6-1

Wiring diagrams
Wiring Diagrams - Single Phase

3 1
6

Split - Sky Air Indoor Unit

Indoor Unit 4-way blow ceiling mounted cassette ACQ-B

7
7-1

Sound data
Sound Pressure Spectrum

1
7

10

Split - Sky Air Indoor Unit

Daikins unique posit ion as a m anufact urer of air condit ioning equipment, com pressors and refrigerants has led to it s close involvement in environment al issues. For several years Daikin has had the int enti on to become a leader i n the provision of products that have limit ed i mpact on the environment. This chall enge demands t he eco desi gn and development of a wide range of products and an energy m anagement system, resulting in energy conservat ion and a reduct ion of waste.

Daikin Europe N. V. participat es in the Eurovent Cert ification programme for Air conditioners (AC), Liquid Chill ing Packages (LCP) and Fan coil unit s (FCU), Check ongoing validity of certifi cate online: www.eurovent -cert ificat ion.com or usi ng: www.certif lash.com

The present leaflet is drawn up by way of inf ormati on only and does not const itut e an of fer binding upon Daikin Europe N.V .. Daikin Europe N.V . has compiled the content of t his l eaf let t o the best of it s knowl edge. No express or i mplied warranty is given f or t he completeness, accuracy, reliability or fit ness f or parti cular purpose of its content and t he product s and services present ed therein. Specifications are subject t o change without prior not ice. Dai kin E urope N.V. expl icit ly rejects any liabi lity f or any direct or indirect damage, in the broadest sense, arising from or related t o t he use and/or int erpret ation of t hi s leaf let. Al l cont ent i s copyright ed by Daikin E urope N.V.

BARCODE

Daikin products are dist ributed by:

N aamloze Ve nnootschap - Z andvoordestraa t 30 0, B-8400 Oostend e - Be lgium - w ww.d aikin.eu - BE 0412 120 336 - R PR Ooste nde

EED EN13 -131 0 1/13 Cop yrigh t Da ikin The p resen t pu bli cation su perse des EEDEN 12-1 31

You might also like