You are on page 1of 40

Plug-in relays Zelio Relay

Catalogue January

06

Contents

Zelio Relay - plug-in relays

Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 2

RSB interface relays


b Presentation, characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 4 and 5 b References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6 b Dimensions, Schemes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7

RXM miniature relays


b Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8 b Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 9 and 10 b References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 11 and 12 b Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 13 and 14 b Schemes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15

RUM universal relays


b Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16 b Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 17 and 18 b References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 19 and 20 b Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 21 and 22 b Schemes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22 b Setting-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 23

RPM power relays


b Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 24 b characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 25 and 26 b References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 27 and 28 b Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 29 and 30 b Schemes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 31

RPF power relays


b Presentation, characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 32 and 33 b References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 34 b Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 35

Zelio Relay - plug-in relays


b Technical appendices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 36 and 37

Selection guide

Zelio Relay - plug-in relays

Application

Plug-in relays Interface relays

Miniature relays

Number and type of contacts / conventional thermal current (Ith on N/O contact)

1 C/O / 16 A 1 C/O / 12 A 2 C/O / 8 A

2 C/O / 12 A 3 C/O / 10 A 4 C/O / 6 A 4 C/O / 3 A (low level) 24240 V 12220 V Flat (Faston type) Up to 250 V 100 000 10 000 000 Yes (depending on version) Yes Yes

Control circuit voltage

a c

24240 V 6110 V Flat (Faston type) Up to a 400 V / c 300 V

Type of pins Operational voltage Durability (operating cycles) Functions Electrical, resistive load Mechanical, no-load LED Test button and mechanical indicator Low level contacts

100 000 30 000 000 Yes (with protection modules)

Type reference

RSB

RXM

Page

11 and 12

Conventional thermal current (Ith) Contact terminal arrangements Connection

12 A (1) Separate Connector

10 A Mixed Screw clamp terminals or connector

12 A (2) Separate Connector

Accessories Protection modules Timer module Maintaining clamps Socket identification legend Mounting adapters for 5 rail Mounting adapters with fixing lugs Bus jumper, 2-pole (Ith = 5 A) Associated socket types

Yes Yes Yes

Yes Yes Yes (except RXZ E2M114) Yes Yes Yes

RSZ E1SppM

RXZ E2Mppp

RXZ E2Sppp

Pages

6 12 12 (1) When using relay RSB 1A160pp with socket RSZ E1S48M, terminals must be linked. (2) Except for sockets RXZ E2S11pM: 10 A.

Relays with clamp fixing Universal relays Power relays

2 C/O / 10 A 3 C/O / 10 A 3 C/O / 3 A (low level)

2 C/O / 10 A 3 C/O / 10 A

1 C/O / 15 2 C/O / 15 3 C/O / 15 4 C/O / 15 24230 V 12110 V

A A A A

2 N/O / 30 A (3) 2 C/O / 30 A (3)

24230 V 12220 V Cylindrical Up to 250 V 100 000 5 000 000 Yes (depending on version) Yes Yes

12110 V Flat (Faston type)

24240 V 12125 V Flat (Faston type) Up to 250 V 50 000 5 000 000

Flat (Faston type) Up to 250 V 100 000 10 000 000 Yes (depending on version) Yes

RUM

RPM

RPF

19

27

34

12 A Mixed Connector Separate

16 A Mixed Connector

Yes Yes Yes Yes

Yes

Yes Yes (for 3 and 4-pole) Yes (on socket RPZ F1) Yes Yes Yes

RUZ CpM

RUZ SCpM

RUZ SF3M

RPZ Fp

20 20 28 (3) 30 A when mounted with 13 mm gap between two relays and 25 A when mounted side by side without a gap.

Presentation, characteristics

Zelio Relay - plug-in relays


1

RSB interface relays

523139

5 2

Presentation of the range


The RSB interface relay range comprises: 1 12 A relays with1 C/O contact , 16 A relays with 1 C/O contact and 8 A relays with 2 C/O contacts. 2 Sockets with separate contact terminals. 3 Protection modules (diode, diode + LED, RC circuit or varistor + LED). All these modules are common to all sockets. 4 A plastic maintaining clamp for all sockets. 5 Clip-in legends for the sockets. 1

3
535188

Socket description
Sockets with separate contact terminals (1) 1 Connection by connector. 2 Five or eight female contacts for the relay pins. 3 A fixing hole for panel mounting. 4 Location for protection modules. 5 Locking components for plastic maintaining clamp. 6 Locating slot for mounting on 5 rail.
(1) The inputs and outputs are separate from the relay supply.

1
Inputs

Outputs

2 5 3 4

Relay supply

General characteristics
Conforming to standards Product certifications Ambient air temperature around the device C Storage C Operation Vibration resistance Conforming to IEC/EN 60068-2-6 Degree of protection Conforming to IEC/EN 60529 Shock resistance Opening conforming to IEC/EN 60068-2-27 Closing Protection category Mounting position IEC/EN 61810-1, UL 508, CSA C22-2 n 14 UL, CSA - 40+ 85 c - 40+ 85, a - 40...+ 70 > 10 gn (10150 Hz) IP 40 5 gn 10 gn RT I Any

Insulation characteristics
Rated insulation voltage (Ui) Conforming to IEC/EN 60947 Rated impulse withstand voltage (Uimp) Dielectric strength Between coil and contact (rms voltage) Between poles Between contacts V kV a V a V a V 400 3.6 (1.2/50 s) 5000 2500 1000

Contact characteristics
Relay type Number and type of contacts Contact materials Conventional thermal current (Ith) Rated operational current in utilisation categories AC-1 and DC-1 Maximum operating rate In operating cycles/hour Switching voltage Switching capacity RSB 1A120pp 1 C/O AgNi 12 12 6 72 000 600 a 400, c 300 5 3000 RSB 1A160pp 1 C/O 16 16 8 RSB 2A080pp 2 C/O 8 8 4

For ambient temperature y 40C Conforming to IEC

A N/O N/C A A

No-load Under load Maximum Minimum Maximum

V mA VA

4000

2000

References: page 6

Dimensions, schemes: page 7

Characteristics

Zelio Relay - plug-in relays


RSB interface relays

Contact characteristics (continued)


Relay type Mechanical durability Electrical durability In millions of operating cycles/hour In millions of operating cycles Resistive load Inductive load RSB 1A120pp u 30 12 A - 250 V: u 0.1 See curves below RSB 1A160 pp 16 A - 250 V: u 0.07 RSB 2A080 pp 8 A - 250 V: u 0.1

Electrical durability of contacts Resistive load a


107
Durability (Number of operating cycles)

Reduction coefficient for inductive load a (depending on power factor cos )


Reduction coefficient (A)

Maximum switching capacity on resistive load c


Current c

1 0,8 0,6 0,5

50 16 12 8 5 2 1 0,5

A
106

B C A

C
105

0,4

104 0 0,4 0,8 1 1,2 1,6 Switching capacity (kVA) 2

0,3 10,8 0,6 0,4 0,2 cos

0,1 10 20 30 50 100 200 300


Voltage c

A RSB 2A080pp

B RSB 1A160pp

C RSB 1A120pp

Durability (inductive load) = durability (resistive load) x reduction coefficient.

Coil characteristics
Average consumption Drop-out voltage threshold Operating time Between coil energisation (response time) and making of the On-delay contact Between coil de-energisation and making of the Off-delay contact a c a c ms ms ms ms V V V c 0.45 W, a 0.75 VA c 0.1 Uc, a 0.15 Uc About 12 About 9 About 10 About 4 6 RD 90 4.8 6.6 12 JD 360 9.6 13.2 24 BD 1440 19.2 26.4 B7 400 19.2 20.4 26.4 48 ED 5700 38.4 52.8 E7 1550 38.4 40.8 57.6 60 ND 7500 48 66 110 FD 25 200 88 121 120 F7 10 200 96 102 144 220 M7 35 500 176 187 264 230 P7 38 500 184 195.5 276 240 U7 42 500 192 204 288

Control circuit voltage Uc Relay control voltage codes DC Average resistance at 20 C 10% Operating Min. voltage limits Max. Relay control voltage codes AC Average resistance at 20 C 15% 50/60 Hz Operating Min. 50 Hz voltage limits 60 Hz Max. 50/60 Hz

V V

Socket characteristics
Socket type Relay types used Product certifications Conventional thermal current (Ith) Degree of protection Conforming to IEC/EN 60529 Connection Solid cable without cable end Flexible cable with cable end Maximum tightening torque Contact terminal arrangement RSZ E1S35M RSB 1A120pp RSZ E1S48M RSB 2A080 pp RSB 1A160 pp (1)

A mm2 mm2 Nm

UL, CSA 12 IP 20 1 conductor: 0.52.5 mm 2 (AWG 20AWG 12) 2 conductors: 0.51.5 mm 2 (AWG 20AWG 14) 1 conductor: 0.22.5 mm 2 (AWG 24AWG 14) 2 conductors: 0.21.5 mm 2 (AWG 24AWG 16) 0.6 (M3 screw) Separate

(1) When using the relay with socket RSZ E1S48M, terminals must be linked. See connection schemes on page 7.

Presentation: page 4

References: page 6

Dimensions, schemes: page 7

References

Zelio Relay - plug-in relays


RSB interface relays

560583

Relays for standard applications


Control circuit voltage Sold in lots of Number and type of contacts - Thermal current (Ith) 1 C/O -12 A 1 C/O -16 A 2 C/O -8 A Unit Unit Unit reference (1) reference (1) reference (1) RSB 1A120RD RSB 1A120JD RSB 1A120BD RSB 1A120ED RSB 1A120ND RSB 1A120FD RSB 1A160RD RSB 1A160JD RSB 1A160BD RSB 1A160ED RSB 1A160ND RSB 1A160FD RSB 2A080RD RSB 2A080JD RSB 2A080BD RSB 2A080ED RSB 2A080ND RSB 2A080FD

Weight kg 0.014 0.014 0.014 0.014 0.014 0.014

V c6 c 12 c 24 c 48 c 60 RSB 1A120JD + RZM 031FPD + RSZ E1S35M c 110

10 10 10 10 10 10

560584

a 24 a 48 a 120 a 220 a 230 a 240

10 10 10 10 10 10

RSB 1A120B7 RSB 1A120E7 RSB 1A120F7 RSB 1A120M7 RSB 1A120P7 RSB 1A120U7

RSB 1A160B7 RSB 1A160E7 RSB 1A160F7 RSB 1A160M7 RSB 1A160P7 RSB 1A160U7

RSB 2A080B7 RSB 2A080E7 RSB 2A080F7 RSB 2A080M7 RSB 2A080P7 RSB 2A080U7

0.014 0.014 0.014 0.014 0.014 0.014

Sockets - 12 A, a 300 V
Contact terminal arrangement RSB 1A160BD + RSZ E1S48M Separate Connection Connector Relay type RSB 1A120pp RSB 1A160pp(2) RSB 2A080pp Voltage V c 6230 a 2460 a 110240 c 624 c 2460 c 110230 c or a 624 c or a 2460 c or a 110230 Sold in lots of 10 10 Unit reference RSZ E1S35M RSZ E1S48M Weight kg 0.060 0.050

560582

Protection modules
Description For use with All sockets All sockets Sold in lots of 20 10 10 10 10 10 10 10 10 Unit reference RZM 040W RZM 041BN7 RZM 041FU7 RZM 031RB RZM 031BN RZM 031FPD RZM 021RB RZM 021BN RZM 021FP Weight kg 0.003 0.010 0.010 0.004 0.004 0.004 0.005 0.005 0.005

Diode RC circuit

Diode + green LED

All sockets

Varistor + green LED RSB 2A080BD + RSZ E1S48M

All sockets

Accessories
560585

Description Plastic maintaining clamp Legend

For use with All sockets All sockets

Sold in lots of 10 10

Unit reference RSZ R215 RSZ L300

Weight kg 0.002 0.001

(1) To order a relay complete with socket (sold in lots of 20): add suffix S to the references selected above. Example: RSB 2A080RD + RSZ E1S48M becomes RSB 2A080RDS. (2) When using the relay with socket RSZ E1S48M, terminals must be linked. See connection schemes on page 7. RSZ R215

Presentation: page 4

Characteristics : pages 4 and 5

Dimensions, schemes: page 7

Dimensions, schemes

Zelio Relay - plug-in relays


1

RSB interface relays

Dimensions
Interface relays
RSB 1A120pp RSB 2A080pp, RSB 1A160pp

3,5

15,7 3,9

12,5 7,5

15,7 3,9 5 29

12,5 7,5

3,5

16,5

2,5

Sockets
RSZ E1S35M RSZ E1S48M

67 61

(4)

67 61

2,5

15

29

(4)

11
14

21

11

24

14

12

22

12

(1)
78,5

(1)
78,5

29,4

(2)
A2 A1

(2)
A2 A1

27,5 34,5 50
(1) Relays (2) Add-on protection module (3) Maintaining clamp (4) Legend

15,5 50

27,5 34,5

15,5

Schemes
Interface relays
RSB 1A120pp RSB 1A160 pp
12/22 14/24

RSB 2A080pp

A2

A2

22

12

12

14

11/21

A1

14

24

A1

11

11

14 11 12

24 21 22

14 11 12

24 21 22

21

A1

A2

When using relay RSB 1A160 pp with socket RSZ E1S48M: terminals 11 and 21, 14 and 24, 12 and 22 must be linked

Presentation: page 4

Characteristics: pages 4 and 5

A1

References: page 6

A2

A1

A2

A1

A2

14 11 12

29,4

(3)

(3)

Presentation

Zelio Relay - plug-in relays


RXM miniature relays

535234

7 2

Presentation of the range


The RXM miniature relay range comprises: 1 12 A relays with 2 C/O contacts, 10 A relays with 3 C/O contacts, 6 A relays with 4 C/O contacts and 3 A low level relays with 4 C/O contacts. All these relays have the same dimensions. 2 Sockets with mixed or separate contact terminals. 3 Protection modules (diode, RC circuit or varistor). All these modules are common to all sockets. 4 A metal maintaining clamp for all sockets. 5 A plastic maintaining clamp for all sockets. 6 A 2-pole bus jumper that can be used on sockets with separate contact terminals in order to simplify cabling when creating an equipotential link between the coil terminals. 7 Clip-in legends for all the sockets except RXZ E2M114.

4 or 5 6 3

Relay description
8 1 2 3 4 7 6 9 5 1 Spring return pushbutton for testing the contacts (green: c, red: a). 2 Mechanical relay status indicator. 3 Removable lock-down door enabling forced maintaining of the contacts for test or maintenance purposes. During operation, this lock-down door must always be in the closed position. 4 LED (depending on version) indicating the relay status. 5 Removable legend for relay identification. 6 Four notches for rail mounting adapter or panel mounting adapter with fixing lugs. 7 Eight, eleven or fourteen Faston type pins. 8 Area by which the product can be easily gripped. 9 Mounting adapter enabling direct mounting of the relay on a panel. 10 Mounting adapter enabling direct mounting of the relay on a 5 rail.
535189

535192

523151

523152

10

6
535190

Socket description
1 Sockets with mixed contact terminals (1) 1 Connection by screw clamp terminals or connector. 2 Fourteen female contacts for the relay pins. 3 Location for protection modules. 4 Locking components for plastic and metal maintaining clamps. 5 Locating slot for mounting on 5 rail with fixing clip. 6 Two or four fixing holes for panel mounting.

Outputs

2 4 3
Inputs

5 6
535191

Relay supply

1
Inputs

Outputs

2 4 3

Sockets with separate contact terminals (2) 1 Connection by connector. 2 Eight, eleven or fourteen female contacts for the relay pins. 3 Location for protection modules. 4 Locking components for plastic and metal maintaining clamps. 5 Locating slot for mounting on 5 rail with fixing clip. 6 Two fixing holes for panel mounting. 7 Location for bus jumpers (see mounting on sockets on page 14).
(1) The inputs are mixed with the relays supply terminals, with the outputs being located on the opposite side of the socket. (2) The inputs and outputs are separated from the relay supply terminals.

5 7

Relay supply

References: pages 11 and 12

Dimensions: pages 13 and 14

Schemes: page 15

Characteristics

Zelio Relay - plug-in relays


RXM miniature relays

General characteristics
Conforming to standards Product certifications C Ambient air temperature around Storage the device Operation C Vibration resistance Conforming to IEC/EN 60068-2-6 Degree of protection Conforming to IEC/EN 60529 Shock resistance Opening conforming to IEC/EN 60068-2-27 Closing Protection category Mounting position IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n 14 UL, CSA pending - 40 + 85 - 40 + 55 > 6 gn (10...50 Hz) IP 40 10 gn 5 gn RT I Any

Insulation characteristics
Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Dielectric strength Between coil and contact (rms voltage) Between poles Between contacts V kV a V a V a V 250 (IEC), 300 (UL, CSA) 3.6 (1.2/50 s) 2500 2500 1500

Contact characteristics
Relay type Number and type of contacts Contact materials Conventional thermal For ambient current (Ith) temperature y 55 C Rated operational current Conforming to IEC N/O in utilisation categories N/C AC-1 and DC-1 Conforming to UL Maximum operating rate No-load In operating cycles/hour Under load Switching voltage Maximum Switching capacity Minimum Maximum Utilisation coefficient Mechanical durability In millions of operating cycles Electrical durability Resistive load In millions of operating Inductive load cycles/hour Electrical durability of contacts Resistive load a RXM 2ABppp 2 C/O AgNi 12 12 6 12 18 000 1200 a/c 250 10 mA on 17 V 3000 20 % 10 0.1 See curves below RXM 3ABppp 3 C/O 10 10 5 10 RXM 4ABppp 4 C/O 6 6 3 6 RXM 4GBppp 4 C/O AgAu 3 2 1 3

V mA VA

2500

1500

2 mA on 5 V 1500

Reduction coefficient for inductive load a (depending on power factor cos )


Reduction coefficient (A)

Maximum switching capacity on resistive load c


Current c

1 0,8 0,6 0,5

Durability (Number of operating cycles)

107

10 6 3

106

0,4

A D C
50 100 150

105 0

D C

B
3 0,3 10,8 0,6 0,4 0,2 cos 0,1 0

1 2 Switching capacity (kVA)

200 250 Voltage c

A RXM 2ABppp

B RXM 3ABppp

C RXM 4ABppp

D RXM 4GBppp

Durability (inductive load) = durability (resistive load) x reduction coefficient.

References: pages 11 and 12

Dimensions: pages 13 and 14

Schemes: page 15

Characteristics substitution

(continued),
1

Zelio Relay - plug-in relays


RXM miniature relays

Coil characteristics
Average consumption Drop-out voltage threshold Operating time (response time) Between coil energisation and making of the On-delay contact Between coil de-energisation and making of the Off-delay contact Control circuit voltage Uc Relay control voltage codes DC Average resistance at 20 C 10% Operating voltage limits a c a c a c a c VA W 1.2 0.9 u 0.15 Uc u 0.1 Uc 20 20 20 20 12 JD 160 9.6 13.2 24 BD 650 19.2 26.4 B7 180 19.2 26.4 48 ED 2600 38.4 52.8 E7 770 38.4 52.8 110 FD 11 000 88 121 120 F7 4430 96 132 125 GD 11 000 100 138 220 MD 14 000 176 242 M7 15 000 176 242 230 P7 15 000 184 253 240 U7 15 500 192 264

ms ms ms ms V

Min. Max.

V V

Relay control voltage codes AC Average resistance at 20 C 15% Operating voltage limits

Min. Max. V V

Socket characteristics
Socket type Relay types used Product certifications Conventional thermal current (Ith) Degree of protection Conforming to IEC/EN 60529 Connection Solid cable without cable end Flexible cable with cable end Maximum tightening torque Contact terminal arrangement Bus jumper Ith: 5 A RXZ E2S108M RXZ E2S111M RXM 2ppppp RXM 3ppppp RXZ E2S114M RXZ E2M114 RXZ E2M114M RXM 4ppppp RXM 2ppppp(1) RXM 2ppppp(1) RXM 4ppppp RXM 4ppppp

UL, CSA (pending) 12 10 IP 20 mm2 1 conductor: 0.52.5 mm2 (AWG 20AWG 12) 2 conductors: 0.51.5 mm2 (AWG 20AWG 14) mm2 1 conductor: 0.22.5 mm2 (AWG 24AWG 14) 2 conductors: 0.21.5 mm2 (AWG 24AWG 16) Nm 0.6 (M3 screw) Separate Mixed Yes No (1) When mounting relay RXM 2ppppp on socket RXZ E2Mpppp, the thermal current must not exceed 10 A. A Old ranges New range

Substitution table
RXN Miniature relays
RXN 21E1ppp RXN 41G1ppp RXN 41G1pppTQ RXN 21E1pppTQ

RXL
RXL 2A12Bppp RXL 3A10Bppp RXL 4A06Bppp RXL 4G06B ppp RXL 2A12Bppp TQ RXL 4A06Bppp TQ

RXM
RXM 2ABppp RXM 3ABppp RXM 4ABppp RXM 4GBppp RXM 2ABpppTQ RXM 4ABpppTQ

Sockets
RXZ E1M114 RXZ 7G RXZ E1M114M RXZ E1p1ppM RXZ E1M114 RXZ 7G RXZ E1M114M RXZ E1p1ppM RXZ E2M114 RXZ E2M114M RXZ E2M114M RXZ E2p1ppM

Protection modules
RXM 040MD RZM 040W RZM 031pp RZM 041pp7 RZM 021pp RXM 040MD RZM 040W RZM 031 pp RZM 041 pp7 RZM 021 pp RXM 040W RXM 040W RXM 040W (2) RXM 041pp 7 RXM 021pp (2)

Accessories
RXZ 200 RXZ 200 RXZ R235 RXZ R235 RXZ L320 RXZ L320 (2) d Protection module without LED. Dimensions: Schemes: pages 13 and 14 page 15 RXZ 400 RXZ R335 RXZ L420

Presentation: page 8

References: pages 11 and 12

10

References

Zelio Relay - plug-in relays


RXM miniature relays

535189

Miniature relays without LED (sold in lots of 10)


Control circuit voltage Number and type of contacts - Thermal current (Ith) 2 C/O -12 A 3 C/O - 10 A Unit Weight Unit Weight reference reference kg kg RXM 2AB1JD 0.037 RXM 3AB1JD 0.038 RXM 2AB1BD 0.037 RXM 3AB1BD 0.038 RXM 2AB1ED 0.037 RXM 3AB1ED 0.038 RXM 2AB1FD 0.037 RXM 3AB1FD 0.038 RXM 2AB1B7 RXM 2AB1E7 RXM 2AB1F7 RXM 2AB1P7 0.037 0.037 0.037 0.037 RXM RXM RXM RXM 3AB1B7 3AB1E7 3AB1F7 3AB1P7 0.038 0.038 0.038 0.038 4 C/O - 6 A Unit reference RXM 4AB1JD RXM 4AB1BD RXM 4AB1ED RXM 4AB1FD RXM 4AB1MD RXM 4AB1B7 RXM 4AB1E7 RXM 4AB1F7 RXM 4AB1P7 RXM 4AB1U7

Weight kg 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.036

RXM pAB2F7

V c 12 c 24 c 48 c 110 c 220 a a a a a 24 48 120 230 240

Miniature relays with LED (sold in lots of 10)


c 12 c 24 c 48 c 110 c 125 a a a a
535189

RXM 2AB2JD RXM 2AB2BD RXM 2AB2ED RXM 2AB2FD RXM 2AB2B7 RXM 2AB2E7 RXM 2AB2F7 RXM 2AB2P7

0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.037

RXM RXM RXM RXM RXM RXM RXM RXM

3AB2JD 3AB2BD 3AB2ED 3AB2FD

0.038 0.038 0.038 0.038 0.038 0.038 0.038 0.038

RXM 4AB2JD RXM 4AB2BD RXM 4AB2ED RXM 4AB2FD RXM 4AB2GD RXM 4AB2B7 RXM 4AB2E7 RXM 4AB2F7 RXM 4AB2P7

0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.036

24 48 120 230

3AB2B7 3AB2E7 3AB2F7 3AB2P7

Miniature relays with low level contacts, without LED (sold in lots of 10)
Control circuit voltage Number and type of contacts Thermal current (Ith) 4 C/O - 3 A Unit Weight reference kg RXM 4GB1JD 0.036 RXM 4GB1BD 0.036 RXM 4GB1ED 0.036 RXM 4GB1FD 0.036 RXM 4GB1B7 RXM 4GB1E7 RXM 4GB1F7 RXM 4GB1P7 0.036 0.036 0.036 0.036

RXM 4GB2F7

V c 12 c 24 c 48 c 110 a a a a 24 48 120 230

Miniature relays with low level contacts, with LED (sold in lots of 10)
c 12 c 24 c 48 c 110 a a a a a 24 48 120 230 240 RXM 4GB2JD RXM 4GB2BD RXM 4GB2ED RXM 4GB2FD RXM 4GB2B7 RXM 4GB2E7 RXM 4GB2F7 RXM 4GB2P7 RXM 4GB2U7 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.036

Presentation: page 8

Characteristics: pages 9 and 10

Dimensions: pages 13 and 14

Schemes: page 15

11

References

(continued)

Zelio Relay - plug-in relays


RXM miniature relays

535235

Miniature relays without LED (sold in lots of 100)


Control circuit voltage Number and type of contacts - Thermal current (Ith) 2 C/O - 12 A Unit Weight reference kg RXM 2AB1BDTQ 0.037 RXM 2AB1B7TQ RXM 2AB1F7TQ RXM 2AB1P7TQ 0.037 0.037 0.037 4 C/O - 6 A Unit reference RXM RXM RXM RXM RXM RXM RXM RXM RXM 4AB1JDTQ 4AB1BDTQ 4AB1EDTQ 4AB1FDTQ 4AB1MDTQ 4AB1B7TQ 4AB1E7TQ 4AB1F7TQ 4AB1P7TQ

Weight kg 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.036

V c 12 c 24 c 48 c 110 c 220 a a a a 24 48 120 230

RXZ E2M114M + Relay RXM 4AB2P7TQ

Miniature relays with LED (sold in lots of 100)


c 24 a 24 a 230 RXM 2AB2B7TQ RXM 2AB2P7TQ 0.037 0.037 RXM 4AB2BDTQ RXM 4AB2B7TQ RXM 4AB2P7TQ 0.036 0.036 0.036

535211

Sockets
Contact terminal arrangement Mixed Connection Screw clamp terminals Connector Separate Connector Relay type RXM 2pppp(3) RXM 4pppp RXM 2pppp(3) RXM 4pppp RXM 2pppp RXM 3pppp RXM 4pppp Sold in lots of 10 10 10 10 10 Unit reference RXZ E2M114 (1) RXZ E2M114M (1) RXZ E2S108M (2) RXZ E2S111M (1) RXZ E2S114M (1) Weight kg 0.048 0.056 0.058 0.066 0.070

Protection modules
RXZ E2S114M + Relay RXM 4AB2F7 Description Voltage V c 6...250 a 24...60 a 110...240 a/c 6...24 a/c 24...60 a/c 110...240 For use with All sockets All sockets All sockets All sockets All sockets All sockets Sold in lots of 20 20 20 20 20 20 Unit reference RXM 040W RXM 041BN7 RXM 041FU7 RXM 021RB RXM 021BN RXM 021FP Weight kg 0.003 0.010 0.010 0.030 0.030 0.030

Diode RC circuit
535212

Varistor

RXM 041 pp7

Timing relays
Description
535195

2 or 4 timed C/O contacts (function A)

For use with Sockets RXZ Eppppp

Unit reference RE XL2pp (4) RE XL4pp (4)

Weight kg

Accessories
Description RE XL4 pp Metal maintaining clamp Plastic maintaining clamp Bus jumper, 2-pole (Ith: 5 A) Mounting adapter for 5 rails (5) Mounting adapter with fixing lugs for panel Clip-in legends For use with All sockets All sockets All sockets with separate contacts All relays All relays All relays (sheet of 108 legends) All sockets except RXZ E2M114 Sold in lots of 10 10 10 10 10 10 10 Unit reference RXZ 400 RXZ R335 RXZ S2 RXZ E2DA RXZ E2FA RXZ L520 RXZ L420 Weight kg 0.001 0.005 0.005 0.004 0.002 0.080 0.001

535215

RXZ 400

(1) Thermal current Ith: 10 A (2) Thermal current Ith: 12 A (3) When mounting relay RXM 2ppppp on socket RXZ E2Mpppp, the thermal current must not exceed 10 A. (4) Please consult the "Zelio Time timing relays" catalogue. (5) Test button becomes inaccessible.

Presentation: page 8

Characteristics: pages 9 and 10

Dimensions: pages 13 and 14

Schemes: page 15

12

Dimensions

Zelio Relay - plug-in relays


RXM miniature relays

Dimensions
Miniature relays
RXM pppppp Common view RXM 2 Pin side view RXM 3 RXM 4

= 6,5 6 4 4

= = =

27

21 7 40 6 21 2,5 13,5 2,5 2,5

21 2,5 13,5 2,5 13,5 4,5 2,5

Sockets
RXZ E2M114 RXZ E2M114M

40 19 25,5

43 17
24 6 14 5 22 2 12 1 44 8 42 4 34 7 32 3 24 14 6 5

(4)
34 7 44 8 42 4 32 3

22 12 2 1

79

61

39,5

80

(1)

(1)

(2) (3)

11 A2 14 41 12 31 11 A1 13 21 10 9

(2) (3)

A2 14 41 12 31 11 21 10

A1 13 11 9

50 3,5 9 23 7 69
RXZ E2S108M RXZ E2S111M RXZ E2S114M

23,5 27

21 30

67

30

Common side view

61 19
41 12 44 8 42 4 11 9 14 5 12 1 31 9 34 6 32 3 22 2 24 5 12 1 21 8 14 4 11 7 41 12 44 8 42 4 31 11 34 7 32 3 21 11 10 9 24 14 6 5 22 12 2 1

(1)

79

38

(2) (3) (5) 29


70
A2 14 A1 13

38

A2 14 13

A1

A2 14 13

A1

3,5

23 7

23,5 27

23,5 27

23,5 27

(1) Relays (2) Add-on protection module (3) Maintaining clamp (4) 2 elongated holes 3.5 x 6.5 (5) 2 bus jumpers

Presentation: page 8

Characteristics: pages 9 and 10

References: pages 11 and 12

Schemes: page 15

38

40

13

Dimensions (continued)

Zelio Relay - plug-in relays


RXM miniature relays

Dimensions (continued)
Plastic clamp and clip-in legends
RXZ R335 RXZ L420 Mounting on all sockets (1)

57 12

26,5 14,2

(1)

27

81

(1) Clip-in legends for all sockets except RXZ E2M114.

Bus jumper
RXZ S2 Mounting on sockets with separate contacts (view from below) Example of bus jumper mounting on sockets

Metal clamp
RXZ 400

25 7,3 26

2,2

22 2,3

(1)

(1) 37

(2)

(2)

1,2

(1) 2 bus jumpers (polarity A2) (2) 2 bus jumpers (polarity A1)

Mounting adapter for rail (1)


RXZ E2DA

Mounting adapter for panel


RXZ E2FA

38

43

48

3,5 6 23 51 4 24 48 49 3

3,5

4 24

(1) Test button becomes inaccessible

Presentation: page 8

Characteristics: pages 9 and 10

References: pages 11 and 12

14

38

94,5

Schemes

Zelio Relay - plug-in relays


RXM miniature relays

Schemes
Miniature relays
RXM 2ppppp
A2 12 14 44 42

RXM 3ppppp
A2 12 14 22 24 34 32

RXM 4ppppp
12 14 22 24 32 34 42 44 A2 4 42 8 44 12 41 14 A2 A1

A1

11

11

21

A1

11

21

41

31

31

1 12 5 14 9 11 13 A1

4 42 8 44 12 41 14 A2

1 12 4 14 7 11 13 A1

2 22 5 24 8 21

3 32 6 34 9 31 14 A2

1 12 5 14 9 11 13 A1

2 22 6 24 10 21

3 32 7 34 11 31

Symbols shown in blue correspond to Nema marking.

Presentation: page 8

Characteristics: pages 9 and 10

References: pages 11 and 12

41

15

Presentation

Zelio Relay - plug-in relays


RUM universal relays

535216

Presentation of the range


The RUM universal relay range comprises: 1 10 A relays with 2 and 3 C/O contacts, with cylindrical or flat (Faston type) pins, and 3 A low level relays with 3 C/O contacts, with cylindrical pins. All these relays have the same dimensions. 2 Sockets with mixed or separate contact terminals. 3 Protection modules (diode, RC circuit or varistor) or 1 timer module. All these modules are common to all sockets. 4 A metal maintaining clamp for all sockets. 5 A 2-pole bus jumper that can be used on sockets with separate contact terminals in order to simplify cabling when creating an equipotential link between the coil terminals. 6 Clip-in legends for the sockets.

4 5 3

7
535196

Relay description
1 2 3 4 1 Spring return pushbutton for testing the contacts (green: c, red: a). 2 Mechanical relay status indicator. 3 Removable lock-down door enabling forced maintaining of the contacts for test or maintenance purposes. During operation, this lock-down door must always be in the closed position. 4 LED (depending on version) indicating the relay status. 5 Removable legend for relay identification. 6 Eight or eleven cylindrical or flat (Faston type) pins. 7 Area by which the product can be easily gripped.

535218

1
Outputs

Socket description
Sockets with mixed contact terminals (1) 1 Connection by connector. 2 Eight or eleven female contacts for the relay cylindrical pins. 3 Location for protection modules or the timer module. 4 Locking component for metal maintaining clamp. 5 Locating slot for 5 rail mounting. 6 Two fixing holes for panel mounting.

2 6 4 3
Relay supply

Inputs Relay supply

6
535197

Inputs

Outputs

4 2a 3

535198

Sockets with separate contact terminals (2) 1 Connection by connector. Inputs 2 a Eight or eleven female contacts for the relay cylindrical pins. b Eleven female contacts for the relay flat pins. 3 Location for protection modules or the timer module. Outputs 4 Locking component for metal maintaining clamp. 5 Locating slot for mounting on 5 rail with fixing clip. 2b 6 Two fixing holes for panel mounting. 7 Location for bus jumpers (see mounting on sockets on page 22). 4 1 3
(1) The inputs are mixed with the relays supply terminals, with the outputs being located on the opposite side of the socket. (2) The inputs and outputs are separated from the relay supply terminals.

57

Relay supply

57

5 Relay supply

References: pages 19 and 20

Dimensions: pages 21 and 22

Schemes: page 22

16

Characteristics

Zelio Relay - plug-in relays


RUM universal relays

General characteristics
Conforming to standards Product certifications Ambient air temperature around the device C Storage Operation C Vibration resistance Conforming to IEC/EN 60068-2-6 Degree of protection Conforming to IEC/EN 60529 Shock resistance Opening conforming to IEC/EN 60068-2-27 Closing Protection category Mounting position IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n 14 UL, CSA (pending) - 40 + 85 - 40 + 55 4 gn (10...50 Hz) IP 40 10 gn 5 gn RT I Any

Insulation characteristics
Rated insulation voltage (Ui) Conforming to IEC/EN 60947 Rated impulse withstand voltage (Ump) Dielectric strength Between coil and contact (rms voltage) Between poles Between contacts V kV a V a V a V 250 (IEC), 300 (UL, CSA) 3.6 (1.2/50 s) 2500 2500 1500

Contact characteristics
Relay type Number and type of contacts Contact materials Conventional thermal For ambient current (Ith) temperature y 55C Rated operational current Conforming to IEC N/O in utilisation categories N/C AC-1 and DC-1 Conforming to UL Maximum operating rate No-load In operating cycles/hour Under load Switching voltage Maximum Switching capacity Minimum Maximum Utilisation coefficient Mechanical durability In millions of operating cycles Electrical durability In millions of operating cycles/hour Resistive load Inductive load . A A A A RUM F2ppp 2 C/O AgNi 10 10 5 10 36 000 3600 a/c 250 10 mA on 17 V 2500 20 % 5 0.1 See curves below Reduction coefficient for inductive load a (depending on power factor cos )
Reduction coefficient (A)

RUM F3 ppp 3 C/O

RUM C2ppp 2 C/O

RUM C3A pp 3 C/O

RUM C3Gpp 3 C/O AgAu 3 2 1 3

V mA VA

3 mA on 5 V 750

Electrical durability of contacts Resistive load a

Maximum switching capacity on resistive load c


Current c

1 0,8 0,6 0,5

Durability (Number of operating cycles)

107

10 3

106

0,4

A B
105 0 1 2 Switching capacity (kVA) 3

0,3 10,8 0,6 0,4 0,2 cos

0,1 0 50 100 150 200 250 Voltage c

A RUM Fppppp, RUM C2ppp, RUM C3Appp

B RUM C3Gppp

Durability (inductive load) = durability (resistive load) x reduction coefficient.

References: pages 19 and 20

Dimensions: pages 21 and 22

Schemes: page 22

17

Characteristics

(continued)

Zelio Relay - plug-in relays


RUM universal relays

Coil characteristics
Average consumption Drop-out voltage threshold Operating time (response time) Between coil energisation and making of the On-delay contact Between coil de-energisation and making of the Off-delay contact a c a c a c a c VA W 2...3 1.4 u 0.15 Uc u 0.1 Uc 20 20

ms ms

ms ms

20 20

Control circuit voltage Uc Relay control voltage codes DC Average resistance at 20 C 10% Operating voltage limits Relay control voltage codes AC Average resistance at 20 C 15% Operating voltage limits

V Min. Max. V V

12 JD 120 9.6 13.2

24 BD 470 19.2 26.4 B7 72 19.2 26.4

48 ED 1800 38.4 52.8 E7 290 38.4 52.8

60 ND 2790 48 66

110 FD 10 000 88 121

120 F7 1700 96 132

125 GD 10 000 100 137.5

220 MD 3700 176 242

230 P7 7200 184 253

Min. Max. V V

Socket characteristics
Socket type Relay types used Product certifications Conventional thermal current (Ith) Degree of protection Conforming to IEC/EN 60529 Connection Solid cable without cable end Flexible cable with cable end Maximum tightening torque Contact terminal arrangement Bus jumper Ith: 5 A RUZ C2M RUZ C3M RUZ SC2M RUM C2ppppp RUM C3 ppppp RUM C2ppppp UL, CSA (pending) 12 IP 20 1 conductor: 0.52.5 mm2 (AWG 20AWG 12) 2 conductors: 0.51.5 mm2 (AWG 20AWG 14) 1 conductor: 0.22.5 mm2 (AWG 24AWG 14) 2 conductors: 0.21.5 mm2 (AWG 24AWG 16) 0.6 (M3 screw) Mixed Separate No Yes RUZ SC3M RUZ SF3M RUM C3 ppppp RUM F ppppp

A mm2 mm2 Nm

Presentation: page 16

References: pages 19 and 20

Dimensions: pages 21 and 22

Schemes: page 22

18

References

Zelio Relay - plug-in relays


RUM universal relays

References
Relays for standard applications, without LED (sold in lots of 10)
Pins Control circuit voltage Number and type of contacts - Thermal current (Ith) 2 C/O -10 A 3 C/O -10 A Unit Weight Unit reference reference kg RUM C2AB1JD 0.084 RUM C3AB1JD RUM C2AB1BD 0.084 RUM C3AB1BD RUM C2AB1ED 0.084 RUM C3AB1ED RUM C3AB1ND RUM C2AB1FD 0.084 RUM C3AB1FD RUM C3AB1GD RUM C3AB1MD RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM C2AB1B7 C2AB1E7 C2AB1F7 C2AB1P7 F2AB1JD F2AB1BD F2AB1ED F2AB1FD F2AB1B7 F2AB1E7 F2AB1F7 F2AB1P7 C2AB2JD C2AB2BD C2AB2ED C2AB2FD 0.084 0.084 0.084 0.084 0.080 0.080 0.080 0.080 0.080 0.080 0.080 0.080 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 RUM C3AB1B7 RUM C3AB1E7 RUM C3AB1F7 RUM C3AB1P7 RUM F3AB1JD RUM F3AB1BD RUM F3AB1ED RUM F3AB1FD RUM F3AB1B7 RUM F3AB1E7 RUM F3AB1F7 RUM F3AB1P7 RUM C3AB2JD RUM C3AB2BD RUM C3AB2ED RUM C3AB2ND RUM C3AB2FD RUM C3AB2GD RUM C3AB2B7 RUM C3AB2E7 RUM C3AB2F7 RUM C3AB2P7 RUM F3AB2JD RUM F3AB2BD RUM F3AB2ED RUM F3AB2FD RUM F3AB2B7 RUM F3AB2E7 RUM F3AB2F7 RUM F3AB2P7

Weight kg 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.086 0.086 0.086 0.086 0.086 0.086 0.086 0.086

Cylindrical

V c 12 c 24 c 48 c 60 c 110 c 125 c 220 a a a a 24 48 120 230 12 24 48 110 24 48 120 230

Flat (Faston type)

c c c c a a a a

535199

Relays for standard applications, with LED (sold in lots of 10)


Cylindrical c 12 c 24 c 48 c 60 c 110 c 125 a a a a Flat (Faston type) c c c c a a a a 24 48 120 230 12 24 48 110 24 48 120 230

RUM ppAB2B7

C2AB2B7 C2AB2E7 C2AB2F7 C2AB2P7 F2AB2JD F2AB2BD F2AB2ED F2AB2FD F2AB2B7 F2AB2E7 F2AB2F7 F2AB2P7

535200

RUM ppAB2F7

Relays with low level contacts, with LED (sold in lots of 10)
Pins Control circuit voltage Number and type of contacts Thermal current (Ith) 3 C/O - 3 A Unit Weight reference kg RUM C3GB2BD 0.086 RUM C3GB2ED 0.086 RUM C3GB2B7 RUM C3GB2E7 RUM C3GB2F7 RUM C3GB2P7 0.086 0.086 0.086 0.086

Cylindrical

V c 24 c 48 a a a a 24 48 120 230

Presentation: page 16

Characteristics: pages 17 and 18

Dimensions: pages 21 and 22

Schemes: page 22

19

References (continued), substitution table

Zelio Relay - plug-in relays


1

RUM universal relays

535199

References (continued)
Sockets
Contact terminal arrangement Mixed Connection Connector Relay type RUM C2ppppp RUM C3 ppppp Separate Connector RUM C2 ppppp RUM C3 ppppp RUM F2 pppp RUM F3 pppp Sold in lots of 10 10 10 10 10 Unit reference RUZ C2M RUZ C3M RUZ SC2M RUZ SC3M RUZ SF3M Weight kg 0.054 0.054 0.095 0.100 0.095

RUZ C3M + relay RUM C3ppppp

Protection modules
Description For use with All sockets All sockets All sockets Voltage V c 6250 a 110240 a/c 24 a/c 240 Sold in lots of 10 10 10 10 Unit reference RUW 240BD RUW 241P7 RUW 242B7 RUW 242P7 Weight kg 0.004 0.004 0.004 0.004

Diode
535202

RC circuit RUW 241P7 Varistor

Timer module
Description
535219

For use with All sockets

Voltage V a/c 24240

Sold in lots of 10

Unit reference RUW 101MW

Weight kg 0.020

Multifunction RUW 101MW

Timing relays
Description 2 timed C/O contacts (single-function or multifunction) For use with On sockets RUZ CpM Reference RE 48A pp (1) Weight kg

Accessories
Description
535217

Metal maintaining clamp RUZ C200 Bus jumper, 2-pole (Ith : 5 A) Clip-in legends

For use with All sockets All sockets with separate contacts All relays (sheet of 108 legends) All sockets with separate contacts

Sold in lots of 10 10 10 10

Unit reference RUZ C200 RUZ S2 RXZ L520 RUZ L420

Weight kg 0.001 0.005 0.080 0.001

535203

RUZ S2

(1) Please consult the "Zelio Time timing relays" catalogue.

Substitution table
Old range New range

RUN Universal relays


RUN 21C2ppp RUN 31C2ppp RUN 21A2ppp RUN 31A2ppp RUN 33A22pp

RUM
RUM RUM RUM RUM RUM F2ABppp F3ABppp C2ABppp C3ABppp C3GB2pp

Sockets
RUZ pA RUZ pD RUZ 1C RUZ C3M RUZ C2M RUZ SF3M RUW 240BD (2) RUW 24ppp (2) RUZ C200

Protection modules
RUW 030BD RUW 04ppp

Accessories
RUZ 2p0 (2) d Protection module without DEL. Presentation: page 16 Characteristics: pages 17 and 18 Dimensions: pages 21 and 22 Schemes: page 22

20

Dimensions

Zelio Relay - plug-in relays


RUM universal relays

Dimensions
Universal relays
RUM Cpp RUM Fpp

34

55

34

53

34

Sockets
Common side view RUZ C2M RUZ C3M

22
24 6 5 22 4 12 14 3 34 9 32 8 24 7 22 5 14 3 12 4

4 3

2x3,1
8 9

6 7 5 4 3 10 11 1 INPUT A1 2 2

2x3,1

(1) (3)
75

7 8 1

(2)

INPUT A2 7 A2 7 A2 7 21

INPUT A1 2

37

37

INPUT A2 10 A2 A2 31 10 21 11 6

11 8

A1 1 2

11 A1 1 2

10

27 63 89 93
RUZ SC2M

30 38

30 38

RUZ SC3M

45 19
22 5 24 6 11 1 21 8 12 4 14 3

63 19
31 11 34 9 32 8 21 6 24 7 22 5 11 1 14 3 12 4

(1)
92

4
6 7

4 3

(1) (3)
2

4
7 6 5 8 4 3 9 10 2 11 1

(3)

40

92

(2) (4)
29 75 102 105 4

(2)
A2 7 A1 2

40
A2 10

34

(4)
29 75 102 105 4

A1 2

30 36

32 36

(1) Relay (2) Protection module (3) Maintaining clamp (4) 2 bus jumpers

Presentation: page 16

Characteristics: pages 17 and 18

References: pages 19 and 20

Schemes: page 22

21

Dimensions (continued) schemes

Zelio Relay - plug-in relays


1

RUM universal relays

Dimensions (continued)
Sockets (continued)
RUZ SF3M

63
21 9 24 6 22 3 31 8 34 5 32 2 11 7 14 4 12 1

(1) (3)
92

(2) (4)
27 46 104 29 4
A2 B A1 A

36

(1) Relay (2) Protection module (3) Maintaining clamp (4) 2 bus jumpers

Metal maintaining clamps and plastic legends


RUZ C200 Mounting

Bus jumper
RUZ S2

35,4 37 3,3 8,5

32 1,2 54 2,3
Mounting on sockets with separate contacts (view from below) Example of bus jumper mounting on sockets (1) (1)

RUZ L420

32 14,2 12

108

(2)

(2)

(1) 2 bus jumpers (polarity A2) (2) 2 bus jumpers (polarity A1)

Schemes
Universal relays
RUM p2ABppp
14 12 22 24 A2

RUM C3 ppppp
14 24 34 12 22 32 A2

RUM F3ABppp
14 34 12 32 22 24 21 2 32 5 34 8 31 A2 A1 3 22 6 24 9 21 B( ) A2

A1

11

21

11

21

31

A1

11

RUM C2AB ppp


22 5 6 24

RUM F2ABppp
1 12 4 14 7 11 A (+) A2 A1 3 22 6 24 9 21 B( ) A2

RUM C3 ppppp
21 6 5 12 4 7 8 32

RUM F3ABppp
1 24 12 4 14 7 11 A (+) A1

12 4 14 3

22

14 3 A1 2 10 1 11 11 31

9 34 A2

A1

2 1 11 8 21

Symbols shown in blue correspond to Nema marking. Presentation: page 16 Characteristics: pages 17 and 18 References: pages 19 and 20

22

31

Setting-up

Zelio Relay - plug-in relays


RUM universal relays

Multifunction timer module RUW 101MW


Programming Timing range selection

Function Timing range selection selection 0.11 s 0.110 s 0.11 min 110 min 0.11 h 110 h 0.11 day 110 days

Function selection
Selection Function On-delay timer E Control Series control Function diagram
U .1/.4 .1/.2 t

Control scheme
U
A1

Flashing relay, starting On-delay phase Bi

Series control

U .1/.4 .1/.2 t t

Flashing relay, starting Off-delay phase Bp

Series control

U .1/.4 .1/.2 t t

Off-delay timer R

Control by external contact (S)

U S

U S
t

A1

.1/.4 .1/.2

A2

Monostable with maintained control Wu

Series control

U .1/.4 .1/.2

Monostable with pulse control Ws

Control by external contact (S)

U S .1/.4 .1/.2

Monostable, starting on de-energisation Wa

Control by external contact (S)

U S .1/.4 .1/.2

On-delay timer Es

Control by external contact (S)

U S .1/.4 .1/.2

Power off Power on

Contact open Contact closed

U: voltage R: relay RUM ppp

S: external control t: adjustable time delay

Presentation: page 16

Characteristics: pages 17 and 18

References: pages 19 and 20

Dimensions: pages 21 and 22

A2

B1

23

Presentation

Zelio Relay - plug-in relays


RPM power relays

523144

Presentation of the range


2 The RPM power relay range comprises: 1 15 A relays with 1, 2, 3 and 4 C/O contacts. 2 Sockets with mixed contact terminals. 3 Protection modules (diode, RC circuit or varistor) or 1 timer module. All these modules are common to all the sockets except for the timer module, which can only be used on the 3-pole or 4-pole sockets. A metal maintaining clamp for 1 contact relays.

8
523145

Relay description
2 3 4 1 Spring return pushbutton for testing the contacts (green: c, red: a). 2 Mechanical relay status indicator. 3 Removable lock-down door enabling forced maintaining of the contacts for test or maintenance purposes. During operation, this lock-down door must always be in the closed position. 4 LED (depending on version) indicating the relay status. 5 Removable legend for relay identification. 6 Four notches for rail mounting adapter or panel mounting adapter with fixing lugs. 7 Five, eight, eleven or fourteen Faston type pins. 8 Area by which the product can be easily gripped. 9 Mounting adapter enabling direct mounting of the relay on a panel. 10 Mounting adapter enabling direct mounting of the relay on a 5 rail.

7 6

523156

523157

523158

9 5
523146

10

Socket description
1
Outputs

Sockets with mixed contact terminals (1) 1 Connection by screw clamp terminals. 2 Five, eight, eleven or fourteen female contacts for the relay pins. 3 Location for protection modules or the timer module. 4 Locating slot for mounting on 5 rail with fixing clip. 5 Two or four fixing holes for panel mounting.
(1) The inputs are mixed with the relays supply terminals, with the outputs being located on the opposite side of the socket.

Supply relay

Inputs

References: pages 27 and 28

Dimensions: pages 29 and 30

Schemes: page 31

24

Characteristics

Zelio Relay - plug-in relays


RPM power relays

General characteristics
Conforming to standards Product certifications Ambient air temperature around the device Vibration resistance Degree of protection Shock resistance conforming to IEC/EN 60068-2-27 Protection category Mounting position Storage Operation Conforming to IEC/EN 60068-2-6 Conforming to IEC/EN 60529 Opening Closing C C IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n 14 UL, CSA (pending) - 40 + 85 - 40 + 55 6 gn (10...50 Hz) IP 40 10 gn 10 gn RT I Any

Insulation characteristics
Rated insulation voltage (Ui) Conforming to IEC/EN 60947 Rated impulse withstand voltage (Uimp) Dielectric strength Between coil and contact (rms voltage) Between poles Between contacts V kV aV aV aV 250 (IEC), 300 (UL, CSA) 3.6 (1.2/50 s) 2500 2500 1500

Contact characteristics
Relay type Number and type of contacts Contact materials Conventional thermal current For ambient (Ith) temperature y 55 C Conforming to IEC N/O Rated operational current in utilisation categories N/C AC-1 and DC-1 Conforming to UL Maximum operating rate No-load In operating cycles/hour Under load Switching voltage Maximum Switching capacity Minimum Maximum Utilisation coefficient Mechanical durability In millions of operating cycles Resistive load Electrical durability In millions of operating Inductive load cycles/hour Electrical durability of contacts Resistive load a RPM 1 ppp 1 C/O AgNi 15 15 7.5 15 18 000 1200 a/c 250 100 mA on c 5 V 3750 20 % 10 0.1 See curves below Reduction coefficient for inductive load a (depending on power factor cos )
Reduction coefficient (A)

RPM 2ppp 2 C/O

RPM 3 ppp 3 C/O

RPM 4ppp 4 C/O

A A A A

V mA VA

0.06

Maximum switching capacity on resistive load c


Current c

Durability (Number of operating cycles)

107

1 0,8 0,6 0,5

15 10

106

0,4

105 0 4 3,75 Switching capacity (kVA) 1 2 3

0,3 10,8 0,6 0,4 0,2 cos

0,1 0 50 100 150 200 250 Voltage c

Durability (inductive load) = durability (resistive load) x reduction coefficient.

References: pages 27 and 28

Dimensions: pages 29 and 30

Schemes: page 31

25

Characteristics

(continued)

Zelio Relay - plug-in relays


RPM power relays

Coil characteristics
Relay type Average consumption Drop-out voltage threshold Operating time (response time) Between coil energisation and making of the On-delay contact Between coil de-energisation and making of the Off-delay contact a c a c a c a c VA W RPM 1ppp 0.9 0.7 u 0.15 Uc u 0.1 Uc 20 20 20 20 12 JD 180 160 100 96 9.6 13.2 24 BD 750 650 400 388 19.2 26.4 B7 160 180 103 84.3 19.2 26.4 48 ED 2600 2600 2600 1550 38.4 52.8 E7 720 770 770 338 38.4 52.8 110 FD 13 100 11 000 8600 7340 88 121 120 F7 4430 4430 2770 2220 96 132 230 P7 15 720 15 000 12 000 9120 184 253 RPM 2ppp 1.2 0.9 RPM 3ppp 1.5 1.7 RPM 4ppp 1.5 2

ms ms ms ms V

25 25

25 25

20 20

Control circuit voltage Uc Relay control voltage codes DC Average resistance at 20 C 10%

Operating voltage limits Relay control voltage codes AC Average resistance at 20 C 15%

RPM RPM RPM RPM Min. Max.

1ppp 2ppp 3ppp 4ppp

V V

Operating voltage limits

RPM RPM RPM RPM Min. Max.

1ppp 2ppp 3ppp 4ppp

V V

Socket characteristics
Socket type Relay types used Protection module types used Product certifications Conventional thermal current (Ith) Degree of protection Conforming to IEC/EN 60529 Connection Solid cable without cable end Flexible cable with cable end Maximum tightening torque Contact terminal arrangement RPZ F1 RPZ F2 RPZ F3 RPM 1ppp RPM 2ppp RPM 3ppp RXM 02ppp RXM 02 ppp RUW 24ppp RXM 04ppp RXM 04 ppp UL, CSA (pending) 16 IP 20 1 conductor: 0.52.5 mm2 (AWG 20AWG 12) 2 conductors: 0.51.5 mm2 (AWG 20AWG 14) 1 conductor: 0.22.5 mm2 (AWG 24AWG 14) 2 conductors: 0.21.5 mm2 (AWG 24AWG 16) 0.8 (M3.5 screw) Mixed RPZ F4 RPM 4ppp RUW 24ppp

A mm2 mm2 Nm

Presentation: page 24

References: pages 27 and 28

Dimensions: pages 29 and 30

Schemes: page 31

26

References

Zelio Relay - plug-in relays


RPM power relays

Power relays without LED (sold in lots of 10)


Control circuit voltage Number and type of contacts - Thermal current (Ith) 1 C/O - 15 A 2 C/O - 15 A 3 C/O - 15 A Unit Weight Unit Weight Unit Weight reference reference reference kg kg kg RPM 11JD 0.024 RPM 21JD 0.036 RPM 31JD 0.054 RPM 11BD RPM 11ED RPM 11FD 0.024 0.024 0.024 RPM 21BD RPM 21ED RPM 21FD 0.036 0.036 0.036 RPM 31BD RPM 31ED RPM 31FD 0.054 0.054 0.054 4 C/O - 15 A Unit Weigh reference t kg 0.068 RPM 41JD RPM 41BD RPM 41ED RPM 41FD 0.068 0.068 0.068

V c 12 c 24 c 48 c 110

a 24 a 48 a 120 a 230

RPM 11B7 RPM 11E7 RPM 11F7 RPM 11P7

0.024 0.024 0.024 0.024

RPM 21B7 RPM 21E7 RPM 21F7 RPM 21P7

0.036 0.036 0.036 0.036

RPM 31B7 RPM 31E7 RPM 31F7 RPM 31P7

0.054 0.054 0.054 0.054

RPM 41B7 RPM 41E7 RPM 41F7 RPM 41P7

0.068 0.068 0.068 0.068

535205

Power relays with LED (sold in lots of 10)


c 12 c 24 c 48 RPM 32F7 c 110 RPM 12JD RPM 12BD RPM 12ED RPM 12FD 0.024 0.024 0.024 0.024 RPM 22JD RPM 22BD RPM 22ED RPM 22FD 0.036 0.036 0.036 0.036 RPM 32JD RPM 32BD RPM 32ED RPM 32FD 0.054 0.054 0.054 0.054 RPM 42JD RPM 42BD RPM 42ED RPM 42FD 0.068 0.068 0.068 0.068

535205

a 24 a 48 a 120 RPM 22F7 a 230

RPM 12B7 RPM 12E7 RPM 12F7 RPM 12P7

0.024 0.024 0.024 0.024

RPM 22B7 RPM 22E7 RPM 22F7 RPM 22P7

0.036 0.036 0.036 0.036

RPM 32B7 RPM 32E7 RPM 32F7 RPM 32P7

0.054 0.054 0.054 0.054

RPM 42B7 RPM 42E7 RPM 42F7 RPM 42P7

0.068 0.068 0.068 0.068

Presentation: page 24

Characteristics: pages 25 and 26

Dimensions: pages 29 and 30

Schemes: page 31

27

References

(continued)

Zelio Relay - plug-in relays


RPM power relays

535206

Sockets
Contact terminal arrangement Mixed Connection Screw clamp terminals Relay type RPM RPM RPM RPM 1ppp 2ppp 3ppp 4ppp Sold in lots of 10 10 10 10 Unit reference RPZ F1 RPZ F2 RPZ F3 RPZ F4 Weight kg 0.042 0.054 0.072 0.094

Protection modules
Description Voltage V c 6...250 Socket type RPZ F1 RPZ F2 RPZ F3 RPZ F4 RPZ F1 RPZ F2 RPZ F1 RPZ F2 RPZ F3 RPZ F4 RPZ F1 RPZ F2 RPZ F1 RPZ F2 RPZ F1 RPZ F2 RPZ F3 RPZ F4 RPZ F3 RPZ F4 Socket type RPZ F3 RPZ F4 Sold in lots of 20 20 20 20 20 20 20 20 20 20 Unit reference RXM 040W RUW 240BD RXM 041BN7 RXM 041FU7 RUW 241P7 RXM 021RB RXM 021BN RXM 021FP RUW 242B7 RUW 242P7 Weight kg 0.003 0.004 0.010 0.010 0.004 0.030 0.030 0.030 0.004 0.004

Diode RPZ F2 + relay RPM 22F7

RC circuit
535207

a 24...60 a 110...240

RXM p41 ppp Varistor a/c 6..0.24 a/c 24...60 a/c 110...240 a/c 24 a/c 240

Timer module (1)


Description Voltage V a/c 24240 Sold in lots of 10 Unit reference RUW 101MW Weight kg 0.020

Multifunction
535208

Accessories
Description Metal maintaining clamp (for single-pole relays) Mounting adapters for 5 rail (2) For use with RPZ F1 RPM RPM RPM RPM RPM RPM RPM RPM 1ppp 2ppp 3ppp 4ppp 1ppp 2ppp 3ppp 4ppp Sold in lots of 20 20 20 20 20 20 20 20 20 10 Unit reference RPZ R235 RPZ 1DA RXZ E2DA RPZ 3DA RPZ 4DA RPZ 1FA RXZ E2FA RPZ 3FA RPZ 4FA RXZ L520 Weight kg 0.001 0.004 0.004 0.004 0.006 0.002 0.002 0.003 0.004 0.080

RPZ 1DA Mounting adapters with fixing lugs for panel


535209

Clip-in legends (sheet of 108 legends)

All relays

RPZ 3FA

(1) See timer module description (selection of functions and time delays) on page 23 (2) Test button becomes inaccessible

Presentation: page 24

Characteristics: pages 25 and 26

Dimensions: pages 29 and 30

Schemes: page 31

28

Dimensions

Zelio Relay - plug-in relays


RPM power relays

Dimensions
Power relays
RPM 1

6,5 6 5

3,5

4,5

27

2 41
Common side view

6 7

14

2,5

2,5

RPM 2

RPM 3

RPM 4

4,5 4,5 6,5 6 5 4

4,5 4,5 4,5

4,5 4,5 4,5 4,5

27

4,5

39

21

27

10 15

31

10

10

40

27

10

10

10

Sockets
RPZ F1 RPZ F2

19
14 5 12 1

19

4,5 x 6
44 8 14 5

40

80

68

80

40

14 11 9

13

A2 14 41 12

A1 13 11 9

31 71 80
Common side view

17 21 76
RPZ F3 RPZ F4

8 30

19 26 30

19

4,5 x 6
44 8 42 4 2 6 22 1 24 5 12 14 8

4,5 x 6
44 7 42 32 3 2 34 6 22 1 24 5 12 14

40

68

80

68

40

A2 14 41 12 10 13 21 9

A1

A2 14 13 41 12 11 31 10 21 9

A1

11

11

8 30 76

28 37 40

36 46 50

Presentation: page 24

Characteristics: pages 25 and 26

References: pages 27 and 28

Schemes: page 31

40

40

29

40

A2

A1

40

42 4

12 1

Dimensions (continued)

Zelio Relay - plug-in relays


RPM power relays

Dimensions (continued)
Mounting adapters for 5 rail
RPZ 1DA RXZ E2DA RPZ 3DA RPZ 4DA

38

49,5

48

50

23 24

2,5

23 2,5 23 24

34

Mounting adapters with fixing lugs for panel


RPZ 1FA RXZ E2FA RPZ 3FA RPZ 4FA

43

38

43

38

43

2,5

20

50

44

3,5 16

5 16,5

43

38

3,5 19

4 24

3,5 19

4 34

16

3,5

4 44

Mounting
Mounting adapters for 5 rail (1) Mounting adapters with fixing lugs for panel

(1) Test button becomes inaccessible

Presentation: page 24

Characteristics: pages 25 and 26

References: pages 27 and 28

Schemes: page 31

30

38

Schemes

Zelio Relay - plug-in relays


RPM power relays

Schemes
Power relays
RPM 1ppp
A2 14 12

RPM 2ppp
12 14 22 24 A2 A1

A1

11

11

1 12 5 14 9 11 13 (+) A1 14 ( ) A2

1 12 3 14 5 11 7 (+) A1

21

2 22 4 24 6 21 8 ( ) A2

RPM 3ppp
A2 12 14 42 44 22 24

RPM 4ppp
12 14 32 34 42 22 24 44 A2 4 42 8 44 12 41 14 ( ) A2 A1

11

41

A1

11

31

21

1 12 5 14 9 11 13 (+) A1

2 22 6 24 10 21

4 42 8 44 12 41 14 ( ) A2

1 12 5 14 9 11 13 (+) A1

21

2 22 6 24 10 21

3 32 7 34 11 31

Symbols shown in blue correspond to Nema marking.

Presentation: page 24

Characteristics: pages 25 and 26

References: pages 27 and 28

41

Dimensions: pages 29 and 30

31

Presentation, characteristics

Zelio Relay - plug-in relays


1

RPF power relays


With clamp fixing

Presentation of the range


RPF power relays with 2 C/O or 2 N/O contacts comprise:
535210

1 2 3 4

Four or six Faston type pins. Two relay supply pins. A locating slot for mounting on 5 rail. Two fixing holes for panel mounting.

General characteristics
Conforming to standards Product certifications Ambient air temperature around the device Vibration resistance Degree of protection Storage Operation Conforming to IEC 60068-2-6 Conforming to IEC/EN 60529 C C IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n14 UL, CSA (pending) - 40...+ 85 - 40...+ 55 >10 gn (10...55 Hz) IP 40 10 gn 10 gn RT IV Any

Shock resistance Opening conforming to IEC/EN 60068-2-27 Closing Protection category Mounting position

Insulation characteristics
Rated insulation voltage (Ui) Conforming to IEC/EN 60947 Rated impulse withstand voltage (Uimp) Dielectric strength (rms voltage) Between coil and contact Between poles Between contacts V kV aV aV aV 250 3.6 (1.2/50 s) 2500 2500 1500

References: page 34

Dimensions, schemes: page 35

32

Characteristics (continued)

Zelio Relay - plug-in relays


RPF power relays
With clamp fixing

Contact characteristics
Relay type Number and type of contacts Contact materials Conventional thermal current (Ith) Rated operational current in utilisation categories AC-1 and DC-1 Maximum operating rate In operating cycles/hour Switching voltage Switching capacity Utilisation coefficient Mechanical durability For ambient temperature y 40C Conforming to IEC Conforming to UL No-load Under load Maximum Minimum Maximum In millions of operating cycles A N/O N/C A A A RPF 2A pp 2 N/O AgSnO2 RPF 2B pp 2 C/O

V mA VA

30 (when mounted with 13 mm gap between two relays) 25 (when mounted side by side without a gap) 30 3 30 18 000 1200 a/c 250 10 mA on c 17 V 7200 10 % 5 0.05 (N/O contact only) See curves below

Resistive load Electrical durability In millions of operating Inductive load cycles/hour Electrical durability of contacts Resistive load a
107
Durability (Number of operating cycles)

Reduction coefficient for inductive load a (depending on power factor cos )


Reduction coefficient (A)

Maximum switching capacity on resistive load c


Current c

1 0,8 0,6 0,5

A B
10

106

105

0,4

104 0 1 2 3 4 5 6 7 8
Switching capacity (kVA)

0,3 10,8 0,6 0,4 0,2 cos

0,1 0 28 50 100 150 200 250 Voltage c

Durability (inductive load) = durability (resistive load) x reduction coefficient.

A RPF 2ppp: 30 A B RPF 2ppp: 25 A

Coil characteristics
Average consumption a c a c Between coil energisation and making of the On-delay contact Between coil de-energisation and making of the Off-delay contact Control circuit voltage Uc Relay control voltage codes DC Average resistance at 20 C 10% Operating voltage limits Relay control voltage codes AC Average resistance at 20 C 15% Operating voltage limits a c a c ms ms ms ms VA W 4 1.7 u 0.15 Uc u 0.1 Uc 20 20 20 20

Drop-out voltage threshold

Operating time (response time)

V Min. Max. V V

12 JD 86 9.6 13.2

24 BD 350 19.2 26.4 B7 250 19.2 26.4

110 FD 7255 88 121

120 F7 1600 96 132

230 P7 6500 184 253

Min. Max. V V

References: page 34

Dimensions, schemes: page 35

33

References

Zelio Relay - plug-in relays


RPF power relays
With clamp fixing

535210

Power relays (sold in lots of 10)


Control circuit voltage Number and type of contacts - Thermal current (Ith) 2 N/O - 30 A (1) 2 C/O - 30 A (1) Unit Unit Weight reference reference kg 0.086 RPF 2AJD RPF 2BJD

V c 12

c 24

RPF 2ABD

RPF 2BBD

0.086

c 110 RPF 2Bpp

RPF 2AFD

RPF 2BFD

0.086

a 24

RPF 2AB7

RPF 2BB7

0.086

a 120

RPF 2AF7

RPF 2BF7

0.086

a 230

RPF 2AP7

RPF 2BP7

0.086

(1) 30 A when mounted with 13 mm gap between two relays and 25 A when mounted side by side without a gap.

Characteristics: pages 32 and 33

Dimensions, schemes: page 35

34

Dimensions, schemes

Zelio Relay - plug-in relays


1

RPF power relays


With clamp fixing

Dimensions
Power relays
RPF 2App , RPF 2Bpp

26 16 2 x 4,5

30 4,5

42

15

60

12 = 34 = 42

Schemes
Power relays
RPF 2App
6 14 2 24

RPF 2Bpp
6 14 8 11 2 24 4 21 3 22

8 11

4 21

7 12

1 A1

0 A2

69
1 A1 0 A2

Symbols shown in blue correspond to Nema marking.

Characteristics: pages 32 and 33

References: page 34

35

Technical appendices

Zelio Relay - plug-in relays

Relays
Contact types
Symbol Configuration Make contact (Normally Open) EU NO USA SPST-NO DPST-NO nPST-NO (1) SPST-NC DPST-NC nPST-NC (1) SPDT DPDT nPDT (1)

Break contact (Normally Closed)

NC

Changeover Contact CO

Utilisation categories
Category AC-1 Type of current a single-phase a 3-phase a 3-phase Applications Resistive or slightly inductive loads.

AC-3

Starting and braking of squirrel cage motors; reversing direction of rotation only after stopping of motor. Starting of squirrel cage motors, inching. Plugging, reversing direction of rotation. Resistive or slightly inductive loads (2). Control of electromagnetic loads (< 72 VA), auxiliary control relays, power contactors, electromagnetic solenoid valves and electromagnets. Control of electromagnetic loads (> 72 VA), auxiliary control relays, power contactors, electromagnetic solenoid valves and electromagnets. Control of electromagnetic loads, auxiliary control relays, power contactors, magnetic solenoid valves and electromagnets.

AC-4

a 3-phase

DC-1 AC-14

c a single-phase

AC-15

a single-phase

DC-13

Protection categories
Category RT 0 RT I Explanation Condition Unenclosed relay Relay not provided with a protective case. Dust protected relay Flux-proof relay Relay provided with a case which protects its mechanism from dust. Relay capable of being automatically soldered without allowing the migration of solder fluxes beyond the intended areas. Relay capable of being automatically soldered and then washed to remove flux residues without risk of ingress of flux or washing solvents. Relay provided with a case which has no venting to the outside atmosphere.

RT II

RT III

Wash-tight relay

RT IV

Sealed relay

Hermetically Sealed relay having an enhanced level of sealing. sealed relay (1) n = number of contacts. (2) The switchable voltage can be doubled, for an equal current, by connecting two contacts in series.

RT V

36

Technical appendices
(continued)
1

Zelio Relay - plug-in relays

Protection modules
Whenever an inductive load is de-energised (coil of a relay or of a contactor), an overvoltage appears at its terminals. This voltage peak can reach several thousand volts and a frequency of several MHz. It is likely to disturb the operation of automation systems which contain electronic devices. Protection modules are used to reduce the voltage peak on de-energisation and they therefore limit the energy of interference signals to a level that will not disturb surrounding coils and electronic devices. These modules are used to avoid: v electromagnetic compatibility problems, v the deterioration of contact materials, v the destruction of insulation due to overvoltage, v the destruction of electronic components. Diode protection module (with or without LED) b Advantages v accumulation of energy allowing current flow in the same direction, v absence of any voltage peaks at the coil terminals, v low cost.
Energy released

U
Supply voltage

Break

Coil voltage with diode protection module (c only)

b v v v

Disadvantages increase in relay drop-out time (3 to 4 times the usual time), no polarity protection, de-energisation of the relay.

Break

Protection module with varistor b Advantages v can be used with a and c supply, v voltage peak limited to about 2 Un, v little effect on relay drop-out time.
t
Limitation of voltage peaks

b Disadvantages v no modification of coil's own oscillating frequency, v limitation of switching frequency.

Energy released

Coil voltage with varistor protection module (a and c)

Break

Protection module with RC circuit b Advantages v coil oscillating frequency reduced to about 150 Hz, v voltage peak limited to 3 Un, v little effect on relay drop-out time.
t U1

S2 (with RC)

b Disadvantages v no protection for low voltages.

S1

Coil voltage with RC circuit protection module (a only)


S1 = S2 = Energy released

U2

37

The efficiency of Telemecanique branded solutions


Used in combination, Telemecanique products provide quality solutions, meeting all your Automation and Control applications requirements.

A worldwide presence
Constantly available b More than 5 000 points of sale in 130 countries. b You can be sure to find the range of products that are right for you and which complies fully with the standards in the country where they are used. Technical assistance wherever you are b Our technicians are at your disposal to assist you in finding the optimum solution for your particular needs. b Schneider Electric provides you with all necessary technical assistance, throughout the world.

Schneider Electric Industries SAS


Head Office 89, bd Franklin Roosevelt 92506 Rueil-Malmaison Cedex France www.schneider-electric.com www.telemecanique.com

Due to evolution of standards and equipment, the characteristics indicated in texts and images of this document do not constitute a commitment on our part without confirmation. Design: Schneider Electric Photos: Schneider Electric Printed by:

ART. 815041

01 / 2006

DIA3ED2051206EN

Simply Smart !

You might also like