Multi-Function

GENERATOR MANAGER
Easy & Cost effective upgrade to existing sites Fuel Cost and OPEX Reducing Device Dual Genset duty cycle controller (for offgrid prime sites) Remotely monitor results and manage operations, with smart alert capability Intelligent Battery and/or Temperature Control Adaptable to +24V or 48V Telecom DC systems or a combination
SP-603 GEM3

GEM3

Over View

The Multi Function GENERATOR MANAGER for Telco BTS

GENSET FUEL SAVING DEVICE, THAT CONTROLS THE GENSET OPERATION BASED ON TELECOM SITE BATTERY VOLTAGE CONDITION and/or SHELTER TEMPERATURE 70% to 100% monthly cost reduction!
Smart Genset Control based on Battery voltage and/or shelter temperature Genset remains OFF while battery (or room temperature) condition is healthy Wide Operating voltage (20V to 60V) Password protected front panel programming Three Dry Contact Alarm Outputs for easy interfacing with Telecom NOC Maintains total battery discharge time & cycles in memory

DUAL GENSET DUTY CYCLE CONTROLLER, FOR OFF-GRID TELECOM SITES POWERED ONLY BY GENSETS
Controlling Two Gensets, with Genset failure alarm, to improve site reliability Two Genset Equal Run duty cycle, with rest, ensures equal wear & tear thus minimizes maintenance costs One Prime Genset Run & Automatic rest Time or Battery based operation Save cost on Dual ATS Panel

DATA MONITORING AND REMOTE MANAGEMENT Ensures and Improves Financial Benefits
Seamless integration with SmartMon.Net Monitor & Analyze Genset & Battery performance and remotely optimize device settings as required Smart alert capability to enable predictive action & preventive maintenance

How to meet goals & beat the challenges? Dont use Generator while battery is good, to reduce diesel cost & maintain Genset life Watch Battery performance closely, to predict failure & take preventive action

SPECIFICATIONS
GENERAL Battery Voltage Monitoring Battery Current (Charging/ Discharging Status + Monitoring) Temperature Monitoring General Accuracy Configuration 3 x (0 - 100VDC) 1 x (200 ADC) Selectable 2 x (0 70C) 2% Front Panel + RS485 Port CONFIGURABLE PARAME TERS Mode of GEM Action Mode of Gensets operation

Battery Based Single Genset / Dual Genset

Battery Based GEM Action (Used with Single Genset) Base Voltage (Bat1 & Bat2) Low Battery Activation ((LB) Bat1 & Bat2) Low Battery Release (Bat1 & Bat 2) Battery based GEM Action (Not for B1) Temperature based GEM Action Over Temperature Activation (HT) Over Temperature Release Extended Run Time for battery based GEM Action Extended Run Time for temperature based GEM Action Extended Run Time Termination (On Full Battery) COMMON Battery 3 Voltage & T2 Temperature Battery Voltages Calibration Resetting Battery Counters Temperature Calibration Current Sensor Range Current Sensor Zero Current Limit Current Sensor Zero Adjust Communication Mode (GPRS) ENVIRONMENTAL Operating Temperature

Communication with MTU (GPRS) Input Voltage Input Current Protection Status LEDs Terminal Display Setting Switches MONITORING & DISPLAY Ambient temperature Battery Voltage Charging & Discharging (Battery Status) Last Battery Voltages (At which battery starts charging) Battery Shift & Total Time Battery Current Display Battery Temperature Display (optional) Battery Charge/Discharge Cycle Counter (reset option) Low Battery Alarm Counter Over Temperature Alarm Counter CONTROL & ALARM OUTPUTS GEM Fail Alarm GEM Active Alarm (Battery Discharge) Critical Output (DG Fail) Alarm Generator 01 (AMF) Control Output Generator 02 (AMF) Control Output Low Battery Alarm Activation (Battery 1 & 2 optional) Low Battery Alarm Release (Battery 1 & 2 optional) Over Temperature Alarm Counter PORTS & CONNECTORS Input Ports Output Ports

RS485 Port 20V 60V DC 50mA 70mA @ 48V DC Reverse Polarity, External Fuse Protection (2 A) Power (Green) Alarm (Red) Active (Orange) LCD (2 x 16 characters) 4 x Push Buttons

24V 21.5 25.5VDC 51.0VDC (0.1V Inc) (LB+0.5)-26.5VDC 53VDC Enable / Disable Enable / Disable 27 40 C 20 to (HT 2) C

48V 46 (0.1V Inc) (LB+1.0)-

10mins (TEST Mode) / 1.024Hrs (0.5Hr Inc) 10mins (TEST Mode) / 1.024Hrs (0.5Hr Inc) Enable / Disable

T1 Bat 1,2 & 3 Bat 1 Bat 1 & 2 Bat 1 & 2 Bat 1 (One string only) T2 Bat 1& 2 (Full cycle only) Bat 1 & 2 T1

Enable / Disable Battery 1, 2 & 3 Battery 1 & 2 T1&T2 25A, 50A, 75A, 100A..200A Any value can be selected 1 10 A Yes Poll / Burst

0 C 60 C 10-90%RH (Non Condensing)

(Com-NC) (2pin Relay, 1A contacts) (Com-NO) (2pin Relay, 1A contacts) (Com-NO) (2pin Relay, 1A contacts) (Com-NO-NC) (3pin Relay, 7A contacts) (Com-NO-NC) (3pin Relay, 7A contacts) Internal Internal Internal

Maximum Humidity PHYSICAL Assembly Length Width Height Weight ACCESSORIES

Din Rail Mounted 62.2mm 210mm 92.7mm 865 grams

1 x Hall Effect Current Sensor


5 x 0.2 Header (2 Way) 3 x 0.2 Header (3 Way) 4 x 0.2 Header (3 Way) 3 x 0.2 Header (2 Way)

Others SalTec Innovations

INTEGRATED POWER SYSTEM

SMART LINE CONDITIONERS

BACK-UP POWER PROTECTION

48 VDC POWER SYSTEM

IPS (For Telco BTS)


MEASUREMENT & CONTROL

1 &3 phase LC
PSU BATTERY CHARGER

UPS
AUTO PHASE SWITCHER

Rectifier
REMOTE MONITORING SYSTEM

DG Auto Mains Fail

Power Measurement

AMF - PMM

SMPS Charger & PSU

APS

SmartMon.Net

REAR VIEW

KARACHI (HO)
18-C, Khayaban-e-Tanzeem, Phase-5, DHA, Karachi-Pakistan Tel: (+92-21) 35864852, 35863873 Fax: (+92-21) 35867144

LAHORE
4-C, Industrial/Muslim Block Allama Iqbal Town, Lahore Tel: (+92-42) 37803696, 37803699 Fax: (+92-42) 37802430

ISLAMABAD
House # 385, Street # 14, Sector G-10/2, Islamabad Tel: (+92-51) 2299556 Fax: (+92-51) 2299556

QUETTA
Suit # 8 Aiwan-e-Mashriq, Dr. Sher M. Road, Quetta Tel: (+92-81) 2822361 Fax: (+92-81) 22820729

info@saltec-powerlink.com

www.saltec-powerlink.com

You might also like