You are on page 1of 3

Crestron setup: CEN-HPRFGW: Important notes for setting up the gateway: If there is no Cresnet, then the gateway will

need to be setup using a straight-thru comms cable. Most modern laptops do not have comm ports and so require the use of a USB to serial comm port adapter. Only use a USB adapter that has a Prolific chipset. These will work with Crestron devices. I would suggest that a temporary Cresnet connection is made to the processor to set the gateway up. CEN-HPRFGW (Cresnet only): 1. Ensure the CEN-HPRFGW is connected to the processor, powered up & operational 2. Using the Crestron Toolbox application: Select Tools > System Info or press the [i] info button to bring up the System Info panel 3. Select the processor from the Address book drop down list at the bottom of the System Info panel 4. Wait a few moments while the System Info panel loads. The Cresnet Devices sub window should contain a list of all devices connected to the Cresnet bus 5. Check that the Cresnet ID for the CEN-HPRFGW is set correctly and appears in the list. If it is skip to the end of this section 6. Set the Cresnet ID: From the Tools menu select Network Device Tree Note: Do NOT select Network Device Tree View 7. Select the processor from the drop down address list at the bottom of the Network Device Tree window. Wait a few moments while the Network Device Tree populates 8. Expand the CEN-HPRFGW so that the Cresnet ID is visible. 9. Right click the Cresnet ID: & select Change Network ID 10.Set the ID CEN-HPRFGW (IP only): Note: This assumes that the Cresnet only setup has been completed or that a serial communication is available. 1. Connect to the gateway using the drop down list at the bottom of the Toolbox System info panel. Either select Comm or TPS-6X (cresnet) 2. Press the [>] button in the top right hand corner of the IP Table sub panel 3. Press [Add Entry] in the IP Table setup dialog 4. Set IP ID 5. Set Device ID: 00 6. Set IP/Address Hostname: 192.168.100.20 (processor) 7. Ensure type is set to master 8. Press [OK] 9. Press Save [Send To Device**] The system will reboot 10.Press [Close] TPS-6X: Putting the panel into setup mode: If a project is running, the MAIN MENU can be accessed using one of two methods: Via the trigger keys:

1. Press and hold the right trigger key on the top of the touchpanel and at the same time touch the upper right corner of the screen. 2. Continue holding the right trigger key and touching the upper right corner of the screen. At the same time, press and hold the left trigger key on the top of the touchpanel. After four seconds, the panel will reset 3. Once the screen turns black, release the left trigger key and the panel will enter the MAIN MENU 4. Release the right trigger key and the touch screen Via Crestron Toolbox: 1. Establish communication with the touchpanel using the Address book 2. Right-click on the device and select Functions > Setup Mode 3. Select [Enter Setup Mode]. The MAIN MENU will be displayed Setting up the TPS-6X for the control system: 1. Place the panel into setup mode (see: Putting the panel into setup mode) 2. Press [COMM] to enter the COMMUNICATIONS menu 3. Press [ETHERNET] to enter the ETHERNET SETUP menu 4. Press DHCP [Disable] 5. Press Static IP Settings [IP Address] 6. Press IP Address: [Edit] 7. Use the [+] & [-] buttons to enter the panel IP address then press [Return] 8. Press Subnet Mask: [Edit] 9. Use the [+] & [-] buttons to enter the Subnet then press [Return] 10.Press Default Router: [Edit] 11.Use the [+] & [-] buttons to enter the gateway details then press [Return] 12.Ensure that you are still in the Comms setup and press [Cresnet] 13.Use the [+] & [-] buttons to set the Cresnet ID 14.Press [RETURN] to go back to the COMMUNICATIONS setup page 15.Press the screen where it says IP Table (Touch to edit) 16.Use the CIP ID [DN] & [UP] buttons to set the CIP 17.Enter the IP address of the processor using the keypad 18.Ensure that DEV ID is set to 0 19.Press [ADD IP] 20.Press [Update IP Table] 21.Press [RETURN] to go back to the COMMUNICATIONS setup page 22.Press [WIRELESS] 23.Press [ACQUIRE START] 24.On the CEN-HPRFGW using a small stylus or non-conducting screwdriver press ACQUIRE 25.Once the TPS-6X has acquired the gateway press [ACQUIRE STOP] 26.Press [RETURN] to go back to the COMMUNICATIONS menu 27.Press [RETURN] to go back to SETUP MODE menu 28.Press [RETURN] to go back to the MAIN MENU 29.Press [Touch Screen Calibration] 30.Press [Perform Calibration] 31.Follow the on-screen instructions 32.From the MAIN MENU press [Exit and Run Program] Uploading the touchpanel: 1. From the Toolbox System Info panel dropdown select the TPS-6X(ip)

2. After the panel has refreshed press the [>] button in the top right hand corner of the Display Project sub panel 3. Ensure that the Send All File Types radio button is selected 4. Check Send Modified Files Only 5. Check Allow improved anti-aliased fonts (16-Level) to load 6. Press [Browse] 7. Navigate to the TPS-6X project file.vtz location on your HDD and press [Open] 8. Press [Send] 9. Press [Close] Uploading the program: 1. From the Toolbox System Info panel dropdown select the processor 2. After the panel has refreshed press the [>] button in the top right hand corner of the Program sub panel 3. Press [Browse] 4. Navigate to the simpl window project file.spz location on your HDD and press [Open] 5. Press [Send] 6. Press [Close]

You might also like