PRODUCT PROGRAM
Input Part Number G0505S-2W G0509S-2W G0512S-2W G0515S-2W H0505S-2W H0509S-2W H0512S-2W H0515S-2W 5 4.5-5.5 Voltage (VDC) Nominal Range Voltage (VDC) 5 9 12 15 5 9 12 15 5 9 12 12 10.8-13.2 15 5 9 12 15 5 9 12 15 24 21.6-26.4 3.3 5 9 12 15 Output Current (mA) Max. 200 111 83 67 400 222 167 133 200 111 83 67 400 222 167 133 200 111 83 67 606 400 222 167 133 Min. 20 12 9 7 40 23 17 14 20 12 9 7 40 23 17 14 20 12 9 7 60 40 23 17 14 74 77 77 77 74 77 77 77 75 78 80 78 75 78 80 78 75 77 80 79 70 75 77 80 79 CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE Efficiency Certificate* (%, Typ.)
APPLICATIONS
The G_S-2W & H_S-2W series are specially designed for applications where a group of polar power supplies are isolated from the input power supply in a distributed power supply system on a circuit board. These products apply to: 1) Where the voltage of the input power supply is fixed (voltage variation 10%); 2) Where isolation is necessary between input and output (isolation voltage 6000VDC); 3) Where the regulation of the output voltage and the output demanding. Such as: purely digital circuits, ordinary low frequency analog circuits, and IGBT power device driving circuits. ripple noise are not
G1205S-2W G1209S-2W G1212S-2W G1215S-2W H1205S-2W H1209S-2W H1212S-2W H1215S-2W G2405S-2W G2409S-2W G2412S-2W G2415S-2W H2403S-2W H2405S-2W H2409S-2W H2412S-2W H2415S-2W
MODEL SELECTION
H0505S-2W
Rat ed Po w er Package St yle Outpu t Voltage Input Voltage Product Series
*CE Certificate:EN60601
COMMON SPECIFICATIONS
Item Storage humidity Operating temperature Storage temperature Lead temperature Temp. rise at full load 1.5mm from case for 10 seconds 15 -40 -55 Test Conditions Min. Typ. Max. 95 85 125 300 30 C Units %
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice. G_S-2W & H_S-2W B/2-2010 Page 1 of 3
ISOLATION SPECIFICATIONS
Item Isolation voltage Isolation resistance Isolation capacitance Test Conditions Min. Typ. Max. Units VDC M 10 pF Tested for 1 minute and 1mA max 6000 Test at 500VDC 1000
TYPICAL CHARACTERISTICS
OUTPUT SPECIFICATIONS
Item Output power Line regulation For Vin change of 1% 10% to 100% load (5V output) Load regulation 10% to 100% load (9V output) 10% to 100% load (12V output) 10% to 100% load (15V output) Output voltage accuracy Temperature drift Ripple & Noise* Switching frequency 100% full load 20MHz Bandwidth (5V input) Full load, nominal input (12V/24V input) 150 45 50
Ambient Temperature ( C )
Test conditions
Min. 0.2
Typ.
Max. 2 1.2
Units W
*Test ripple and noise by parallel cable method. See detailed operation instructions at Testing of Power Converter section, application notes.
Note: Dual output models unbalanced load: 5%.
APPLICATION NOTE
1) Requirement on output load To ensure this module can operate efficiently and reliably, During operation, the minimum output load could not be less than 10% of the full load. If the actual output power is very small, please connect a resistor with proper resistance at the output end in parallel to increase the load; or use our companys products with a lower rated output power (G_S-1W & H_S-1W). 2) Recommended testing and application circuit If you want to further decrease the input/output ripple, an LC filtering network may be connected to the input and output ends of the DC/DC converter, see (Figure 1). It should also be noted that the inductance and the frequency of the LC filtering network should be staggered with the DC/DC frequency to avoid mutual interference. However, the capacitance of the output filter capacitor must be proper. If the capacitance is too big, a startup problem might arise. For every channel of output, provided the safe and reliable operation is ensured, the greatest capacitance of its filter capacitor sees (Table 1). 3) Output Voltage Regulation and Over-voltage Protection Circuit The simplest device for output voltage regulation, over-voltage and over-current protection is a linear voltage regulator with overheat protection that is connected to the input or output end in series (Figure 2).
RECOMMENDED CIRCUIT
Si n gle Ou tput
L L
Vin
Cin
+Vo
DC DC
C out
0V
L
+Vo 0V -Vo
DC DC (Figure 1)
GND
L Cout
+Vo
DC DC
0V
+Vo 0V
DC DC
REG
-Vo
(Figure 2)
4) Overload Protection Under normal operating conditions, the output circuit of these products has no protection against overload. The simplest method is to connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit. 5) No parallel connection or plug and play
Single Cout Dual Cout Vout (F) Vout (F) (VDC) (VDC) 5 10 5 4.7 9 12 4.7 2.2 9 12 2.2 1
15 1 15 0.47 It s not recommended to connect any external capacitor in the application field with less than 0.5 watt output.
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice. G_S-2W & H_S-2W B/2-2010 Page 2 of 3
MECHANICAL DIMENSIONS
19.50 [0.768]
RECOMMENDED FOOTPRINT
DUAL OUTPUT 2.00 [0.079] 9.80 [0.386] 2.80 [0.110] 1 2 5 6 7 2.54 [0.100] 2.54 [0.100] 14.00 [0.551] 1.00 [0.039]
(Side View)
12.50 [0.492]
SINGLE OUTPUT
(Bottom View) 1 2 2.80 [0.110] 2.00 [0.079] 0.50 [0.020] 20.00 [0.787] 5 6 7 0.30 [0.012]
FOOTPRINT DETAILS Pin 1 2 5 6 7 Single Vin GND 0V No Pin +Vo Dual Vin GND -Vo 0V +Vo
Note: Unit:mm[inch] Pin section tolerances: 0.10mm[ 0.004inch] General tolerances: 0.25mm[ 0.010inch]
Note:
6.00 [0.236] Note: Unit :mm[inch] General tolerances: 0.50mm[ 0.020inch] L=530mm[20.866inch] Devices per tube quantity: 25pcs L=220mm[8.661inch] Devices per tube quantity: 10pcs
1. Operation under minimum load will not damage the converter; However, they may not meet all specification listed, and that will reduce the life of product. 2. All specifications measured at Ta=25C, humidity<75%, nominal input voltage and rated output load unless otherwise specified. 3. Only typical models listed, other models may be different, please contact our technical person for more details. 4. In this datasheet, all the test methods of indications are based on corporate standards.
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice. G_S-2W & H_S-2W B/2-2010 Page 3 of 3