You are on page 1of 44

Edition 01 / 2012

The foundation of the cable factory KABELWERK EUPEN AG as manufacturer of electrical cables goes back to the beginning of the 20th century. Today the company has a staff of 950 people producing power cables, telecommunication cables and RF-Cables. Since broadband transmission became possible, KABELWERK EUPEN AG has been involved in the design and manufacture of coaxial cables. The introduction of Cable Television in 1962 was decisive for the start of producing coaxial cables on a larger scale. With the increasing demand for coaxial cables and the intensive R&D to improve cable construction and transmission characteristics, KABELWERK EUPEN AG has become today one of the leading manufacturer for coaxial cables in the World. Over 50 years of experience in the field of RF-Cables, the company constantly developed its extensive manufacturing processes bearing in mind the improvement of quality.

Since 1993 the company is ISO 9001 certified for all its products. Today the cables and connectors from KABELWERK EUPEN AG, together is an unbeatable match to guarantee superior performances and long service life.

Kabelwerk Eupen AG

Contents

Introduction
Introduction to EC3 cables and connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Soldered jumper cables


. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Accessories for cables


1. Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 2. Torque wrench. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 3. Grounding clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 4. Fixing clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 5. Hoisting grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 6. Sealant SIL-744 for connectors with sealant injection . . . . . . . . . . 37 7. Eucaseal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 8. Lightning arresters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 9. Weatherproofing tape kit . . . . . . . . . . . . . . . . . . . . . . . 41

Coaxial cables, connectors, tools & grounding clamps


EC3 Foam Dielectric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1/4 Hiflex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1/2 Hiflex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 7/8 Hiflex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 1-1/4 Hiflex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 1/4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 1/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 7/8A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 1-1/4A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 1-5/8A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 2-1/4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Cable packaging information


. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

Technical data, designs and specifications presented in this catalogue are not binding and are subject to change without prior notice. Kabelwerk Eupen AG 3

Over the world


EUPEN CABLE MEXICO SA
Avenida Manta 705 Lindavista, 07300 Mexico, D.F. MEXICO

EUPEN CABLE USA I nc .


5181 110th Avenue North Unit D, Clearwater, Florida - 33760 USA

EUPEN CABLES FRANCE


ZA La Haie Griselle 24, rue du 8 Mai 1945 94470 Boissy St Leger FRANCE

KABELWERK RHENANIA G mb H
Karl-Kuck-Str. 3 52078 Aachen DEUTSCHLAND

KABELWERK EUPEN AG
Malmedyer Strasse 9 4700 Eupen BELGIUM

Agencies Europe Austria Bulgaria Czech Republic Finland Hungary Ireland Italy Norway Poland Romania Russia Serbia Slovenia Spain Sweden Turkey Ukraine United Kingdom

Agencies America Canada USA New Jersey Texas Guatemala

Agencies Asia Hong Kong India Kingdom of Saudi Arabia Kuwait Lebanon Pakistan Singapore Taiwan R.O.C. Thailand

Agencies Africa Egypt South Africa

Agencies Oceania Australia

Kabelwerk Eupen AG

Over the world

EC3:

Eupen Corrugated Copper Cables


Antenna stations in mobile, cellular, microwave and broadcast communication systems require high quality coaxial cables and connectors for very low loss and high power signal transmission. attachment of any of the connectors. High quality silver plating is used on all parts in the electrical path, with electroless nickel plating on all mechanical parts. They feature superior electrical performances. EC3 Cables are offered in sizes ranging from 1/4 to 2-1/4. A full range of type N, DIN and EIA EC3 Connectors are available to complete the package, including hanging and grounding accessories, as well as other accessories needed to complete installation. In addition to the cables in this catalogue we can provide: - Phase stabilised, phase measured cable - Low VSWR microwave versions - Special colours - Cable assemblies Our quality products are delivered fast and on time, saving time and money. Eupen has a staff of engineers to provide complete technical support for our products and to help you to select the best cable for your application. We can provide training to assure the best installation of your system.

EUPEN cables and cable accessories are specifically designed for the needs of modern radio communication systems.
EC3 Cable from Eupen offers better electrical performance and greater durability than conventional corrugated copper cables. It is the best choice for LTE and other wireless communication applications requiring a cable with the lowest loss and best long term durability. The more durable construction of the EC3 Cable allows us to offer the best warranty in the industry 12 years. The electrical specifications of the EC3 Cable are unsurpassed. Every reel is swept for attenuation and return loss before it leaves the factory. Return loss is typically 30 dB and guaranteed to be at least 23 dB over the cellular and PCS bands, when the cable is terminated with EC3 Connectors. Attenuation specifications are the best in the industry. EC3 Connectors are the easiest attaching corrugated copper cable connectors made. No soldering is required for the

Kabelwerk Eupen AG

EC3

F OA M D I E L E C T R I C
EUPEN cables feature innovative design, careful choice of raw materials, consistent manufacturing and quality assurance techniques. The result is a coaxial cable with superior launched electrical and mechanical performances.
Our coaxial cable design with low density cellular polyethylene foam dielectric and ring-corrugated copper outer conductor and our 50 years of experience in manufacturing these cables are your guarantee of the supply of a technically optimal construction, featuring: - lowest loss - excellent flexibility - excellent RF shielding - very low VSWR - easy and reliable installation of connectors Thanks to intensive R&D, Eupen improved in 2006 the attenuation of its most common sections and launch the ultra low loss A version for 7/8, 1-1/4 and 1-5/8. The cable inner conductor is constructed from copperclad aluminium wire, copper tube or corrugated copper tube, depending on the cable size.

The dielectric is a cellular polyethylene foam manufactured by a proprietary process using ozone friendly expansion gas. A high foaming ratio guarantees low attenuation. The foam dielectric is bonded to the inner conductor by a precoating layer. This layer ensures good adhesion of the dielectric to the inner conductor. It also permits easy, clean removal of the dielectric during connector installation. The ring-corrugation of the copper outer conductor captures the dielectric mechanically and ensures good adhesion to the dielectric. This construction prevents relative movement between the inner and the outer conductor due to bending, pulling and temperature variations. The standard cable construction uses an all-weather and UV-resistant black (or grey) PE jacket, suitable for indoor, outdoor or underground installation. For applications requiring flame-retardance, coaxial cables are available with a flame retardant and halogen free jacket. This construction meets international standards for flame propagation, such as IEC 60332-1-2, smoke density IEC 61034-1+2 and acidity of evolved gases IEC 60754-2. For very severe installation requirements, cable constructions with steel tape or wire armouring are available.

Kabelwerk Eupen AG

Halogen Free & Fire resistant

H A LO G E N F R E E and F I R E R E S I S TA N T f e a t u r e s
Test on flammability
a) Test on flammability of single cables
Test in accordance with: IEC 60332-1-2 EN 60332-1-2

b) Test on flammability of cable bundles


Test in accordance with: IEC 60332-3 Cat. C EN 50266-2-4 Cat. C

Test on smoke density


Test in accordance with: IEC 61034-1 and -2 EN 61034-1 and -2

Test on corrosive gas emissions


Test in accordance with: IEC 60754-2 EN 50267-2-2

Test on insulation integrity


Test in accordance with: IEC 60331-23 VDE 0472 Part 814

Kabelwerk Eupen AG

LT E
4G

Qualified

1/4 Hiflex
STANDARD

3/8 Hiflex*

1/2 Hiflex

7/8 Hiflex 1-1/4 Hiflex

Cable type Product reference

5042 EC1-50-HF

5082 EC2-50-HF

5092 EC4-50-HF

5228X EC5-50-HF

5328X EC6-50-HF

Cable with stand 5042-HLFR EC1-50-HF-FR 5082-HLFR EC2-50-HF-FR 5092-HLFR EC4-50-HF-FR 5228X-HLFR EC5-50-HF-FR 5328X-HLFR EC6-50-HF-FR

HLFR

Cable type Product reference

Cable with halogen free and flame retardan CHARACTERISTICS Construction Outer diameter Mechanical Minimum bending radius single bending (cm) Electrical
Relative prop. velocity

(mm)

7.5

10.3

13.6

28.0

39.0

2.5

2.5

15

(%)

82

82 2.28 9.19 13.76 19.85 21.49 22.73 24.27 3.48 0.86 0.58 0.40 0.37 0.35 0.33 7.2

82 1.68 6.96 10.57 15.51 16.86 17.89 19.18 5.66 1.37 0.90 0.61 0.57 0.53 0.50 12.8 13.2

88 0.67 2.76 4.19 6.14 6.67 7.08 7.58 14.49 3.51 2.31 1.58 1.45 1.37 1.28 90 5.1

88 0.47 1.99 3.05 4.51 4.91 5.22 5.61 22.66 5.40 3.53 2.38 2.19 2.06 1.91 180 3.3

Nominal attenuation at 20 C

30 MHz (dB/100m) 3.06 450 MHz (dB/100m) 12.20 960 MHz (dB/100m) 18.16 1880 MHz (dB/100m) 26.00 2170 MHz (dB/100m) 28.10 2400 MHz (dB/100m) 29.68 2700 MHz (dB/100m) 31.65 Mean power rating at 40 C ambient temperature 30 MHz 450 MHz 960 MHz 1880 MHz 2170 MHz 2400 MHz 2700 MHz
RF peak power

(kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW)

2.26 0.57 0.38 0.27 0.25 0.23 0.22 3.6

Cut-off frequency (GHz) 22 15.6 * Please consult us for availability, as minimum order quantities may apply. ** Not qualified for LTE application above 2.3 GHz 8 Kabelwerk Eupen AG

7/8 Foam-Dielectric Foam-Dielectric

1/4

3/8 *

1/2

5/8 *

7/8A
Ultra Low Loss

1-1/4A
Ultra Low Loss

1-5/8A
Ultra Low Loss

2-1/4 * **
5528 EC12-50

5062 EC1-50

5088 EC2-50

5128 EC4-50

5168 EC4.5-50

5228 A EC5-50-A

5328 A EC6-50-A

5438 A EC7-50-A

dard jacket - halogen free in acc. with IEC 60754 5062-HLFR EC1-50-FR 5088-HLFR EC2-50-FR 5128-HLFR EC4-50-FR 5168-HLFR EC4.5-50-FR 5228A-HLFR EC5-50-A-FR 5328A-HLFR EC6-50-A-FR 5438A-HLFR EC7-50-A-FR 5528-HLFR EC12-50-FR

nt jacket in acc. with IEC 60754-2, 60332-1-2, 60332-3 Cat. C & 61034-1+2

9.7

11.8

16.0

21.9

28.0

39.0

50.0

60.0

10

10

20

20

25

82 2.32 9.38 14.05 20.27 21.95 23.22 24.81 3.24 0.80 0.54 0.37 0.34 0.32 0.30 6.9 18.6

88 1.69 6.79 10.14 14.59 15.79 16.69 17.82 4.11 1.02 0.68 0.48 0.44 0.42 0.39 11 14.2

88 1.17 4.72 7.07 10.20 11.04 11.68 12.48 6.74 1.67 1.12 0.77 0.71 0.68 0.63 25.6 9.8

88 0.81 3.29 4.94 7.16 7.76 8.22 8.79 9.27 2.28 1.52 1.05 0.96 0.91 0.85 62 6.5

89 0.62 2.50 3.75 5.43 5.88 6.22 6.65 14.60 3.60 2.40 1.66 1.53 1.45 1.35 86 5.1

88 0.44 1.80 2.72 3.98 4.32 4.58 4.91 21.24 5.17 3.42 2.34 2.15 2.03 1.90 184 3.7

89 0.36 1.47 2.23 3.25 3.53 3.74 4.01 28.27 6.88 4.55 3.12 2.87 2.71 2.53 302 2.8

88 0.29 1.27 1.99 3.03 3.32 40.86 9.30 5.93 3.90 3.56 462 2.3

Kabelwerk Eupen AG

1/4

Hiflex

STANDARD
Cable type : Reference :

5042
5042 EC1-50-HF

FLAME RETARDANT
Cable type : Reference :

HLFR
5042-HLFR EC1-50-HF-FR

Cable with standard UV resistant PE jacket, halogen free according to IEC 60754

Cable with UV resistant, halogen free, low smoke, flame retardant jacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3 Cat. C and IEC 61034-1+2

CHARACTERISTICS
Construction Inner conductor Material Diameter (mm) Dielectric Material Diameter (mm) Outer conductor Material Diameter (mm) Jacket Material Thickness (mm) Diameter (mm) copper clad aluminium wire 1.9 gas-injected cellular polyethylene 4.6 corrugated copper tube 6.4 black polyethylene 0.55 7.5 Electrical Characteristic impedance () Nominal capacity (pF/m) Relative propagation velocity (%) Inductance (H/m) DC-resistance at 20 C - inner conductor (/km) - outer conductor (/km) RF peak voltage (kV) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (M.km) Attenuation[1] and power rating Frequency Attenuation at 20 C [3] (MHz) (dB/100m) 10 1.76 20 2.49 30 3.06 80 5.03 100 5.63 150 6.93 200 8.03 300 9.89 400 11.48 450 12.20 500 12.89 600 14.18 700 15.37 800 16.49 894 17.49 960 18.16 1000 18.56 1500 23.03 1700 24.63 1800 25.40 1880 26.00 2000 26.89 2170 28.10 2200 28.31 2300 29.00 2400 29.68 2500 30.35 2700 31.65 3000 33.53 4000 39.31 6000 49.36 50 1.5 80 82 0.203 9.2 4.4 0.6 3.6 22 >>5000 Mean power rating [4] (kW) 3.93 2.77 2.26 1.37 1.23 1.00 0.86 0.70 0.60 0.57 0.54 0.49 0.45 0.42 0.39 0.38 0.37 0.30 0.28 0.27 0.27 0.26 0.25 0.24 0.24 0.23 0.23 0.22 0.21 0.18 0.14

Mechanical Minimum bending radius a) single bending (cm) b) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range - Storage - Installation - Operation Maximum length per hoisting grip (m) Maximum hanger spacing Flat plate crush resistance (kg/mm) Bending moment (Nm) Approximate weight[2] (kg/km) 2.5 2.5 30 -70 to +85 C -40 to +60 C -55 to +85 C 70 1.8 1.1 83 / 88

[1] a = 0.552 b = 0.0011 () = a . f + b . f [dB/100m] [2] Standard PE jacket / HLFR jacket [3] Nominal values [4] Ambient temperature = 40 C; Temperature of inner conductor = 100 C; VSWR = 1.0; no solar loading

10

Kabelwerk Eupen AG

1/4

Hiflex

716MB14X

NM50B14X

NF50P14X

NM50BL14X

CONNECTORS & TOOLS


Reference Description Specification of
Electrical Nominal impedance () Return loss at 3 GHz (dB) Insulation resistance (G) Test voltage (at sea level) (kV rms, 50 Hz) Working voltage (at sea level) (kV rms, 50 Hz) Screening effectiveness up to 1 GHz (dB) Outer contact resistance (m) Inner contact resistance (m) PIM ratio (2 x 20 W carrier) (dBc) Mechanical Torque on coupling nut (Nm) Cable retention (N) Environmental Temperature range (C) Degree of protection (humidity) Materials SPTC50B14X External parts Outer contact Inner contact Dielectric Gaskets * 30 for right angle connector ** >250 for right angle connector Passivated silver plated or electroless nickel plated brass Passivated silver plated brass Passivated silver plated high-strength copper alloy TPX/PTFE TPX High quality silicone -40 to +85 IP67/IP68 (mated connectors) 8 >400** 30 >600 50 34* 5 2.5 1 >128 1 1.5 -155 (Typical -163) 50 34* 10 4 2.7 >128 1 1.5

N-connectors

7-16 connectors

NM50B14X N male, with silicone gasket NF50B14X N female, with silicone gasket NF50P14X N female, with silicone gasket, panel mount NM50BL14X N male, right angle, with silicone gasket 716MB14X 7-16 DIN male, with silicone gasket 716FP14X 7-16 DIN female, with silicone gasket, panel mount SPTC50B14X Cable preparation tool Cutting knife Spare parts for cable preparation tools Peeling knife (Refer to installation instructions of the tool)

ACCESSORIES
Description
Fixing clamps Additional weatherproofing

Reference
see page 35 see page 41

Kabelwerk Eupen AG

11

1/2

Hiflex

STANDARD
Cable type : Reference :

5092
5092 EC4-50-HF

FLAME RETARDANT
Cable type : Reference :

HLFR
5092-HLFR EC4-50-HF-FR

Cable with standard UV resistant PE jacket, halogen free according to IEC 60754

Cable with UV resistant, halogen free, low smoke, flame retardant jacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3 Cat. C and IEC 61034-1+2

CHARACTERISTICS
Construction Inner conductor Material Diameter (mm) Dielectric Material Diameter (mm) Outer conductor Material Diameter (mm) Jacket Material Thickness (mm) Diameter (mm) copper clad aluminium wire 3.55 gas-injected cellular polyethylene 9.0 corrugated copper tube 12.2 black polyethylene 0.7 13.6 Electrical Characteristic impedance () Nominal capacity (pF/m) Relative propagation velocity (%) Inductance (H/m) DC-resistance at 20 C - inner conductor (/km) - outer conductor (/km) RF peak voltage (kV) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (M.km) Attenuation[1] and power rating Frequency Attenuation at 20 C [3] (MHz) (dB/100m) 10 0.96 20 1.37 30 1.68 80 2.79 100 3.13 150 3.88 200 4.51 300 5.60 400 6.53 450 6.96 500 7.38 600 8.15 700 8.87 800 9.55 894 10.16 960 10.57 1000 10.82 1500 13.62 1700 14.63 1800 15.12 1880 15.51 2000 16.08 2170 16.86 2200 17.00 2300 17.45 2400 17.89 2500 18.33 2700 19.18 3000 20.42 4000 24.29 6000 31.21 50 1 82 82 0.203 2.65 3.05 1.1 12.8 13.2 >>5000 Mean power rating [4] (kW) 9.90 6.96 5.66 3.42 3.04 2.46 2.11 1.70 1.46 1.37 1.29 1.17 1.07 1.00 0.94 0.90 0.88 0.70 0.65 0.63 0.61 0.59 0.57 0.56 0.55 0.53 0.52 0.50 0.47 0.39 0.31

Mechanical Minimum bending radius a) single bending (cm) b) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range - Storage - Installation - Operation Maximum length per hoisting grip (m) Maximum hanger spacing Flat plate crush resistance (kg/mm) Bending moment (Nm) Approximate weight
[2]

3 3 70 -70 to +85 C -40 to +60 C -55 to +85 C 70 0.5 2.05 2.2 193 / 205

(kg/km)

[1] a = 0.30018 b = 0.001327 () = a . f + b . f [dB/100m] [2] Standard PE jacket / HLFR jacket [3] Nominal values [4] Ambient temperature = 40 C; Temperature of inner conductor = 100 C; VSWR = 1.0; no solar loading

12

Kabelwerk Eupen AG

1/2

Hiflex

716MBL12X

NF50B12X

716MB12X

NM50BL12X

CONNECTORS & TOOLS


Reference Description Specification of
Electrical Nominal impedance () Return loss at 3 GHz (dB) Insulation resistance (G) Test voltage (at sea level) (kV rms, 50 Hz) Working voltage (at sea level) (kV rms, 50 Hz) Screening effectiveness up to 1 GHz (dB) Outer contact resistance (m) Inner contact resistance (m) PIM ratio (2 x 20 W carrier) (dBc) Mechanical Torque on coupling nut (Nm) Cable retention (N) Environmental Temperature range (C) Degree of protection (humidity) Materials SPTC50B12X External parts Outer contact Inner contact Dielectric Gaskets SPTC50BL12X * 30 for right angle connector Passivated silver plated or electroless nickel plated brass Passivated silver plated brass Passivated silver plated high-strength copper alloy TPX/PTFE High quality silicone -40 to +85 IP67/IP68 (mated connectors) 8 >400 30 >700 50 34* 5 2.5 1 >128 1 1 -155 (Typical -163) 50 34* 10 4 2.7 >128 1 1

N-connectors

7-16 connectors

716MB12X 7-16 DIN male, with silicone gasket 716FB12X 7-16 DIN female, with silicone gasket 716MBL12X 7-16 DIN male, right angle, with silicone gasket NM50B12X N male, with silicone gasket NF50B12X N female, with silicone gasket NM50BL12X N male, right angle, with silicone gasket SPTC50B12X Cable preparation tool for straight connectors SPTC50BL12X Cable preparation tool for right angle connectors Cutting knife Spare parts for cable preparation tools Peeling knife (Refer to installation instructions of the tool)

ACCESSORIES
Description
Grounding clamp with normal outlet Fixing clamps Additional weatherproofing

Reference
GCS12X see page 35 see page 41 GCS12X

Kabelwerk Eupen AG

13

7/8

Hiflex

STANDARD
Cable type : Reference :

5228X
5228X EC5-50-HF

FLAME RETARDANT
Cable type : Reference :

HLFR
5228X-HLFR EC5-50-HF-FR

Cable with standard UV resistant PE jacket, halogen free according to IEC 60754

Cable with UV resistant, halogen free, low smoke, flame retardant jacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3 Cat. C and IEC 61034-1+2

CHARACTERISTICS
Construction Inner conductor Material Diameter (mm) Dielectric Material Diameter (mm) Outer conductor Material Diameter (mm) Jacket Material Thickness (mm) Diameter (mm) corrugated copper tube 9.4 gas-injected cellular polyethylene 23.4 corrugated copper tube 25.0 black polyethylene 1.4 28.0 Electrical Characteristic impedance () Nominal capacity (pF/m) Relative propagation velocity (%) Inductance (H/m) DC-resistance at 20 C - inner conductor (/km) - outer conductor (/km) RF peak voltage (kV) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (M.km) Attenuation and power rating Frequency Attenuation at 20 C [3] (MHz) (dB/100m) 10 0.38 20 0.54 30 0.67 80 1.11 100 1.24 150 1.54 200 1.79 300 2.22 400 2.59 450 2.76 500 2.92 600 3.23 700 3.51 800 3.78 894 4.02 960 4.19 1000 4.28 1500 5.39 1700 5.79 1800 5.98 1880 6.14 2000 6.36 2170 6.67 2200 6.72 2300 6.90 2400 7.08 2500 7.25 2700 7.58 3000 8.07 4000 9.60 6000 [1]

50 1 76 88 0.189 2.5 1.02 3.0 90 5.1 >>5000 Mean power rating [4] (kW) 25.34 17.82 14.49 8.74 7.79 6.30 5.41 4.36 3.74 3.51 3.31 3.00 2.75 2.56 2.40 2.31 2.26 1.80 1.67 1.62 1.58 1.52 1.45 1.44 1.40 1.37 1.33 1.28 1.20 1.01 -

Mechanical Minimum bending radius a) single bending (cm) b) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range - Storage - Installation - Operation Maximum length per hoisting grip (m) Maximum hanger spacing Flat plate crush resistance (kg/mm) Bending moment (Nm) Approximate weight[2] (kg/km) 9 12.5 130 -70 to +85 C -40 to +60 C -55 to +85 C 70 1.2 1.7 8.4 475 / 525

[1] a = 0.11905 b = 0.000518 () = a . f + b . f [dB/100m] [2] Standard PE jacket / HLFR jacket [3] Nominal values [4] Ambient temperature = 40 C; Temperature of inner conductor = 100 C; VSWR = 1.0; no solar loading

14

Kabelwerk Eupen AG

7/8

Hiflex

716FA78M

716FV78M

CONNECTORS & TOOL


Reference
716MV78M 716FV78M 716MA78M 716FA78M NM50V78M NF50V78M SPTC50AV78X Inner ring Outer ring Spring Cutting knife Peeling knife Flaring knife SIL-744 90ml SIL-744 310 ml

Description
7-16 DIN male, O-Ring 7-16 DIN female, O-Ring 7-16 DIN male, Sealant injection 7-16 DIN female, Sealant injection N male, O-Ring N female, O-Ring Cable preparation tool Spare parts for cable preparation tool (Refer to installation instructions of the tool)

Specification of
Electrical

N-connectors
50 34 5 2.5 1 >128 0.7 1

7-16 connectors
50 34 10 4 2.7 >128 0.7 1

Nominal impedance () Return loss at 3 GHz (dB) Insulation resistance (G) Test voltage (at sea level) (kV rms, 50 Hz) Working voltage (at sea level) (kV rms, 50 Hz) Screening effectiveness up to 1 GHz (dB) Outer contact resistance (m) Inner contact resistance (m) PIM ratio (2 x 20 W carrier) (dBc) Mechanical Torque on coupling nut (Nm) Cable retention (N) Environmental Temperature range (C) Degree of protection (humidity) Materials External parts Outer contact Inner contact Dielectric Gaskets

Sealant for connectors using sealant injection Sealant for connectors using sealant injection

-155 (Typical -163)

Rem.: Sealant for connectors using the sealant injection method must be purchased separately.

8 >400

30 >1000

-40 to +85 IP67/IP68 (mated connectors)

Passivated silver plated or electroless nickel plated brass Passivated silver plated brass Passivated silver plated high-strength copper alloy and brass PTFE TPX High quality silicone

SPTC50AV78X

ACCESSORIES
Description
Grounding clamp with parallel outlet Fixing clamps Additional weatherproofing Lace-up hoisting grip Pre-laced hoisting grip

Reference
GCS78PAR see page 35 see page 41 HG-78 HG-78-L see page 37 GCS78PAR

Kabelwerk Eupen AG

15

1-1/4

Hiflex

STANDARD
Cable type : Reference :

5328X
5328X EC6-50-HF

FLAME RETARDANT
Cable type : Reference :

HLFR
5328X-HLFR EC6-50-HF-FR

Cable with standard UV resistant PE jacket, halogen free according to IEC 60754

Cable with UV resistant, halogen free, low smoke, flame retardant jacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3 Cat. C and IEC 61034-1+2

CHARACTERISTICS
Construction Inner conductor Material Diameter (mm) Dielectric Material Diameter (mm) Outer conductor Material Diameter (mm) Jacket Material Thickness (mm) Diameter (mm) corrugated copper tube 13.6 gas-injected cellular polyethylene 33.5 corrugated copper tube 36.0 black polyethylene 1.5 39.0 Electrical Characteristic impedance () Nominal capacity (pF/m) Relative propagation velocity (%) Inductance (H/m) DC-resistance at 20 C - inner conductor (/km) - outer conductor (/km) RF peak voltage (kV) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (M.km) Attenuation[1] and power rating Frequency Attenuation at 20 C [3] (MHz) (dB/100m) 10 0.27 20 0.38 30 0.47 80 0.79 100 0.89 150 1.10 200 1.28 300 1.59 400 1.86 450 1.99 500 2.11 600 2.33 700 2.55 800 2.74 894 2.92 960 3.05 1000 3.12 1500 3.94 1700 4.25 1800 4.39 1880 4.51 2000 4.68 2170 4.91 2200 4.95 2300 5.09 2400 5.22 2500 5.35 2700 5.61 3000 5.98 4000 6000 50 1 76 88 0.189 1.95 0.63 4.3 180 3.3 >>5000 Mean power rating [4] (kW) 39.73 27.90 22.66 13.62 12.12 9.78 8.39 6.74 5.76 5.40 5.09 4.60 4.22 3.91 3.67 3.53 3.44 2.72 2.53 2.44 2.38 2.30 2.19 2.17 2.11 2.06 2.01 1.91 1.79 -

Mechanical Minimum bending radius a) single bending (cm) b) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range - Storage - Installation - Operation Maximum length per hoisting grip (m) Maximum hanger spacing Flat plate crush resistance (kg/mm) Bending moment (Nm) Approximate weight[2] (kg/km) 15 25 190 -70 to +85 C -40 to +60 C -55 to +85 C 70 1.4 3.4 25 754

[1] a = 0.084 b = 0.000461 () = a . f + b . f [dB/100m] [2] Standard PE jacket [3] Nominal values [4] Ambient temperature = 40 C; Temperature of inner conductor = 100 C; VSWR = 1.0; no solar loading

16

Kabelwerk Eupen AG

1-1/4

Hiflex

NF50V114N1

716FV114N1

CONNECTORS & TOOL


Reference
716MV114N1 716FV114N1 716MA114M 716FA114M NM50V114N1 NF50V114N1 SPTC50AV114X Inner ring Outer ring Spring Cutting knife Peeling knife SIL-744 90ml SIL-744 310 ml

Description
7-16 DIN male, O-Ring 7-16 DIN female, O-Ring 7-16 DIN male, Sealant injection 7-16 DIN female, Sealant injection N male, O-Ring N female, O-Ring Cable preparation tool Spare parts for cable preparation tool (Refer to installation instructions of the tool)

Specification of
Electrical

N-connectors

7-16 connectors
50 35* 10 4 2.7 >128

Sealant for connectors using sealant injection Sealant for connectors using sealant injection

Nominal impedance () 50 Return loss at 3 GHz (dB) 35 Insulation resistance (G) 5 Test voltage (at sea level) 2.5 (kV rms, 50 Hz) Working voltage (at sea level) 1 (kV rms, 50 Hz) Screening effectiveness >128 up to 1 GHz (dB) Outer contact resistance (m) Inner contact resistance (m) PIM ratio (2 x 20 W carrier) (dBc) Mechanical

1.0 1.0 -155 (Typical -163)

Rem.: Sealant for connectors using the sealant injection method must be purchased separately.

Torque on coupling nut (Nm) Cable retention (N) Environmental Temperature range (C) Degree of protection (humidity) Materials External parts Outer contact Inner contact Dielectric Gaskets * sealant injection type: 34

8 >1000

30

-40 to +85 IP67/IP68 (mated connectors)

Passivated silver plated or electroless nickel plated brass Passivated silver plated brass Passivated silver plated high-strength copper alloy and brass TPX High quality silicone

SPTC50AV114X

ACCESSORIES
Description
Grounding clamp with parallel outlet Fixing clamps Additional weatherproofing Lace-up hoisting grip Pre-laced hoisting grip

Reference
GCS114PAR see page 35 see page 41 HG-114 HG-114-L see page 37 GCS114PAR

Kabelwerk Eupen AG

17

1/4

STANDARD
Cable type : Reference :

5062
5062 EC1-50

FLAME RETARDANT
Cable type : Reference :

HLFR
5062-HLFR EC1-50-FR

Cable with standard UV resistant PE jacket, halogen free according to IEC 60754

Cable with UV resistant, halogen free, low smoke, flame retardant jacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3 Cat. C and IEC 61034-1+2

CHARACTERISTICS
Construction Inner conductor Material Diameter (mm) Dielectric Material Diameter (mm) Outer conductor Material Diameter (mm) Jacket Material Thickness (mm) Diameter (mm) copper clad aluminium wire 2.4 gas-injected cellular polyethylene 6.5 corrugated copper tube 7.5 black polyethylene 1.1 9.7 Electrical Characteristic impedance () Nominal capacity (pF/m) Relative propagation velocity (%) Inductance (H/m) DC-resistance at 20 C - inner conductor (/km) - outer conductor (/km) RF peak voltage (kV) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (M.km) Attenuation and power rating Frequency Attenuation at 20 C [3] (MHz) (dB/100m) 10 1.33 20 1.89 30 2.32 80 3.83 100 4.29 150 5.29 200 6.14 300 7.58 400 8.81 450 9.38 500 9.91 600 10.92 700 11.86 800 12.73 894 13.52 960 14.05 1000 14.36 1500 17.90 1700 19.18 1800 19.79 1880 20.27 2000 20.98 2170 21.95 2200 22.12 2300 22.68 2400 23.22 2500 23.76 2700 24.81 3000 26.33 4000 31.02 6000 39.25
[1]

50 1 82 82 0.203 5.85 3.3 0.8 6.9 18.6 >>5000 Mean power rating [4] (kW) 5.64 3.98 3.24 1.96 1.75 1.42 1.23 0.99 0.85 0.80 0.76 0.69 0.63 0.59 0.56 0.54 0.52 0.42 0.39 0.38 0.37 0.36 0.34 0.34 0.33 0.32 0.32 0.30 0.29 0.24 0.19

Mechanical Minimum bending radius a) single bending (cm) b) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range - Storage - Installation - Operation Maximum length per hoisting grip (m) Maximum hanger spacing Flat plate crush resistance (kg/mm) Bending moment (Nm) Approximate weight[2] (kg/km) 3 8 40 -70 to +85 C -40 to +60 C -55 to +85 C 70 0.8 1.5 111 / 124

[1] a = 0.41769 b = 0.00115 () = a . f + b . f [dB/100m] [2] Standard PE jacket / HLFR jacket [3] Nominal values [4] Ambient temperature = 40 C; Temperature of inner conductor = 100 C; VSWR = 1.0; no solar loading

18

Kabelwerk Eupen AG

1/4

NF50A14

NM50AL14

CONNECTORS & TOOLS


Reference
716MA14 716FA14 NM50A14 NF50A14 NM50AL14 SPTC50A14 Cutting knife Peeling knife

Description
7-16 DIN male, O-Ring 7-16 DIN female, O-Ring N male, O-Ring N female, O-Ring N male, right angle, O-Ring Cable preparation tool Spare parts for cable preparation tools (Refer to installation instructions of the tool)

Specification of
Electrical

N-connectors
50 34* 5 2.5 1 >128 1 1.5

7-16 connectors
50 34* 10 4 2.7 >128 1 1.5

Nominal impedance () Return loss at 3 GHz (dB) Insulation resistance (G) Test voltage (at sea level) (kV rms, 50 Hz) Working voltage (at sea level) (kV rms, 50 Hz) Screening effectiveness up to 1 GHz (dB) Outer contact resistance (m) Inner contact resistance (m) PIM ratio (2 x 20 W carrier) (dBc) Mechanical Torque on coupling nut (Nm) Cable retention (N) Environmental

-155 (Typical -163)

8 >400

30 >700

SPTC50A14

Temperature range (C) Degree of protection (humidity) Materials External parts Outer contact Inner contact Dielectric Gaskets * 30 for right angle connector

-40 to +85 IP67/IP68 (mated connectors)

Passivated silver plated or electroless nickel plated brass Passivated silver plated brass Passivated silver plated high-strength copper alloy and brass TPX/PTFE High quality silicone

ACCESSORIES
Description
Grounding clamp with normal outlet Fixing clamps Additional weatherproofing

Reference
GCS14 see page 35 see page 41 GCS14

Kabelwerk Eupen AG

19

1/2

STANDARD
Cable type : Reference :

5128
5128 EC4-50

FLAME RETARDANT
Cable type : Reference :

HLFR
5128-HLFR EC4-50-FR

Cable with standard UV resistant PE jacket, halogen free according to IEC 60754

Cable with UV resistant, halogen free, low smoke, flame retardant jacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3 Cat. C and IEC 61034-1+2

CHARACTERISTICS
Construction Inner conductor Material Diameter (mm) Dielectric Material Diameter (mm) Outer conductor Material Diameter (mm) Jacket Material Thickness (mm) Diameter (mm) copper clad aluminium wire 4.8 gas-injected cellular polyethylene 12.4 corrugated copper tube 13.8 black polyethylene 1.1 16.0 Electrical Characteristic impedance () Nominal capacity (pF/m) Relative propagation velocity (%) Inductance (H/m) DC-resistance at 20 C - inner conductor (/km) - outer conductor (/km) RF peak voltage (kV) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (M.km) Attenuation[1] and power rating Frequency Attenuation at 20 C [3] (MHz) (dB/100m) 10 0.67 20 0.95 30 1.17 80 1.93 100 2.16 150 2.66 200 3.09 300 3.82 400 4.44 450 4.72 500 4.99 600 5.50 700 5.97 800 6.41 894 6.80 960 7.07 1000 7.23 1500 9.01 1700 9.65 1800 9.96 1880 10.20 2000 10.55 2170 11.04 2200 11.13 2300 11.41 2400 11.68 2500 11.95 2700 12.48 3000 13.24 4000 15.59 6000 19.73 50 1 76 88 0.189 1.48 2.04 1.6 25.6 9.8 >>5000 Mean power rating [4] (kW) 11.75 8.28 6.74 4.09 3.65 2.96 2.55 2.07 1.78 1.67 1.58 1.43 1.32 1.23 1.16 1.12 1.09 0.88 0.82 0.79 0.77 0.75 0.71 0.71 0.69 0.68 0.66 0.63 0.60 0.51 0.40

Mechanical Minimum bending radius a) single bending (cm) b) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range - Storage - Installation - Operation Maximum length per hoisting grip (m) Maximum hanger spacing Flat plate crush resistance (kg/mm) Bending moment (Nm) Approximate weight[2] (kg/km) 7 12 100 -70 to +85 C -40 to +60 C -55 to +85 C 70 1 1.9 3.5 231 / 253

[1] a = 0.2105 b = 0.00057 () = a . f + b . f [dB/100m] [2] Standard PE jacket / HLFR jacket [3] Nominal values [4] Ambient temperature = 40 C; Temperature of inner conductor = 100 C; VSWR = 1.0; no solar loading

20

Kabelwerk Eupen AG

1/2

NF50A12

716FV12

716MAL12

CONNECTORS & TOOL


Reference
716MV12 716FV12 716MA12 716FA12 716MVL12 716MAL12 NM50V12 NF50V12 NM50A12 NF50A12 NM50VL12 NM50AL12 SPTC50AV12 Cutting knife Peeling knife SIL-744 90ml SIL-744 310 ml

Description
7-16 DIN male, O-Ring 7-16 DIN female, O-Ring 7-16 DIN male, Sealant injection 7-16 DIN female, Sealant injection 7-16 DIN male, right angle, O-Ring 7-16 DIN male, right angle, Sealant injection N male, O-Ring N female, O-Ring N male, Sealant injection N female, Sealant injection N male, right angle, O-Ring N male, right angle, Sealant injection Cable preparation tool Spare parts for cable preparation tool (Refer to installation instructions of the tool) Sealant for connectors using sealant injection Sealant for connectors using sealant injection

Specification of
Electrical

N-connectors
50 34* 5 2.5 1 >128 1 1

7-16 connectors
50 34* 10 4 2.7 >128 1 1

Nominal impedance () Return loss at 3 GHz (dB) Insulation resistance (G) Test voltage (at sea level) (kV rms, 50 Hz) Working voltage (at sea level) (kV rms, 50 Hz) Screening effectiveness up to 1 GHz (dB) Outer contact resistance (m) Inner contact resistance (m) PIM ratio (2 x 20 W carrier) (dBc) Mechanical Torque on coupling nut (Nm) Cable retention (N) Environmental Temperature range (C) Degree of protection (humidity) Materials External parts Outer contact Inner contact Dielectric Gaskets

-155 (Typical -163)

8 >500**

30 >1000***

Rem.: Sealant for connectors using the sealant injection method must be purchased separately.

-40 to +85 IP67/IP68 (mated connectors)

Passivated silver plated or electroless nickel plated brass Passivated silver plated brass Passivated silver plated high-strength copper alloy and brass TPX/PTFE TPX High quality silicone

SPTC50AV12

* 30 for right angle connector ** >400 for N-right angle connector *** >700 for 7-16 right angle connector

ACCESSORIES
Description
Grounding clamp with parallel outlet Fixing clamps Additional weatherproofing Lace-up hoisting grip Pre-laced hoisting grip

Reference
GCS12PAR see page 35 see page 41 HG-12 HG-12-L see page 37 GCS12PAR

Kabelwerk Eupen AG

21

7/8 A
Ultra Low Loss

STANDARD
Cable type : Reference :

5228 A
5228 A EC5-50-A

FLAME RETARDANT
Cable type : Reference :

HLFR
5228A-HLFR EC5-50-A-FR

Cable with standard UV resistant PE jacket, halogen free according to IEC 60754

Cable with UV resistant, halogen free, low smoke, flame retardant jacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3 Cat. C and IEC 61034-1+2

CHARACTERISTICS
Construction Inner conductor Material Diameter (mm) Dielectric Material Diameter (mm) Outer conductor Material Diameter (mm) Jacket Material Thickness (mm) Diameter (mm) smooth copper tube 9.2 gas-injected cellular polyethylene 23.5 corrugated copper tube 25.0 black polyethylene 1.4 28.0 Electrical Characteristic impedance () Nominal capacity (pF/m) Relative propagation velocity (%) Inductance (H/m) DC-resistance at 20 C - inner conductor (/km) - outer conductor (/km) RF peak voltage (kV) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (M.km) Attenuation and power rating Frequency Attenuation at 20 C [3] (MHz) (dB/100m) 10 0.35 20 0.50 30 0.62 80 1.02 100 1.14 150 1.41 200 1.63 300 2.02 400 2.35 450 2.50 500 2.64 600 2.91 700 3.16 800 3.40 894 3.61 960 3.75 1000 3.83 1500 4.79 1700 5.13 1800 5.30 1880 5.43 2000 5.62 2170 5.88 2200 5.92 2300 6.07 2400 6.22 2500 6.37 2700 6.65 3000 7.06 4000 8.33 6000 [1]

50 1 75 89 0.187 1.55 1.31 2.9 86 5.1 >>5000 Mean power rating [4] (kW) 25.46 17.93 14.60 8.85 7.89 6.40 5.51 4.46 3.83 3.60 3.41 3.09 2.85 2.65 2.49 2.40 2.35 1.88 1.75 1.70 1.66 1.60 1.53 1.52 1.48 1.45 1.41 1.35 1.27 1.08 -

Mechanical Minimum bending radius a) single bending (cm) b) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range - Storage - Installation - Operation Maximum length per hoisting grip (m) Maximum hanger spacing Flat Plate Crush resistance (kg/mm) Bending moment (Nm) Approximate weight[2] (kg/km) 10 25 140 -70 to +85 C -40 to +60 C -55 to +85 C 70 1.2 1.4 11.6 436 / 486

[1] a = 0.1107 b = 0.000333 () = a . f + b . f [dB/100m] [2] Standard PE jacket / HLFR jacket [3] Nominal values [4] Ambient temperature = 40 C; Temperature of inner conductor = 100 C; VSWR = 1.0; no solar loading

22

Kabelwerk Eupen AG

7/8 A

NM50V78N1

716FV78N1

CONNECTORS & TOOL


Reference
716MV78N1 716FV78N1 716MA78MA 716FA78MA NM50V78N1 NF50V78N1 SPTC50AV78M Inner ring Outer ring Spring Cutting knife Peeling knife Flaring knife SIL-744 90ml SIL-744 310 ml

Description
7-16 DIN male, O-Ring 7-16 DIN female, O-Ring 7-16 DIN male, Sealant injection 7-16 DIN female, Sealant injection N male, O-Ring N female, O-Ring Cable preparation tool Spare parts for cable preparation tool (Refer to installation instructions of the tool)

Specification of
Electrical

N-connectors
50 35 5 2.5 1 >128

7-16 connectors
50 35* 10 4 2.7 >128

Nominal impedance () Return loss at 3 GHz (dB) Insulation resistance (G) Test voltage (at sea level) (kV rms, 50 Hz) Working voltage (at sea level) (kV rms, 50 Hz) Screening effectiveness up to 1 GHz (dB) Outer contact resistance (m) Inner contact resistance (m) PIM ratio (2 x 20 W carrier) (dBc) Mechanical Torque on coupling nut (Nm) Cable retention (N) Environmental Temperature range (C) Degree of protection (humidity) Materials External parts Outer contact Inner contact Dielectric Gaskets * sealant injection type: 34

Sealant for connectors using sealant injection Sealant for connectors using sealant injection

1.0 1.0 -155 (Typical -163)

8 >1000

30

Rem.: Sealant for connectors using the sealant injection method must be purchased separately. EIA connectors available on request.

-40 to +85 IP67/IP68 (mated connectors)

Passivated silver plated or electroless nickel plated brass Passivated silver plated brass Passivated silver plated high-strength copper alloy and brass TPX High quality silicone

SPTC50AV78M

ACCESSORIES
Description
Grounding clamp with parallel outlet Fixing clamps Additional weatherproofing Lace-up hoisting grip Pre-laced hoisting grip

Reference
GCS78PAR see page 35 see page 41 HG-78 HG-78-L see page 37

GCS78PAR

Kabelwerk Eupen AG

23

1-1/4 A
Ultra Low Loss

STANDARD
Cable type : Reference :

5328 A
5328 A EC6-50-A

FLAME RETARDANT
Cable type : Reference :

HLFR
5328 A-HLFR EC6-50-A-FR

Cable with standard UV resistant PE jacket, halogen free according to IEC 60754

Cable with UV resistant, halogen free, low smoke, flame retardant jacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3 Cat. C and IEC 61034-1+2

CHARACTERISTICS
Construction Inner conductor Material Diameter (mm) Dielectric Material Diameter (mm) Outer conductor Material Diameter (mm) Jacket Material Thickness (mm) Diameter (mm) smooth copper tube 13.0 gas-injected cellular polyethylene 33.5 corrugated copper tube 36.0 black polyethylene 1.5 39.0 Electrical Characteristic impedance () Nominal capacity (pF/m) Relative propagation velocity (%) Inductance (H/m) DC-resistance at 20 C - inner conductor (/km) - outer conductor (/km) RF peak voltage (kV) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (M.km) Attenuation[1] and power rating Frequency Attenuation at 20 C [3] (MHz) (dB/100m) 10 0.25 20 0.36 30 0.44 80 0.73 100 0.81 150 1.01 200 1.17 300 1.45 400 1.69 450 1.80 500 1.91 600 2.10 700 2.29 800 2.46 894 2.62 960 2.72 1000 2.79 1500 3.50 1700 3.76 1800 3.88 1880 3.98 2000 4.12 2170 4.32 2200 4.35 2300 4.47 2400 4.58 2500 4.69 2700 4.91 3000 5.22 4000 6000 50 1 76 88 0.189 0.95 0.63 4.3 184 3.7 >>5000 Mean power rating [4] (kW) 37.13 26.12 21.24 12.84 11.44 9.26 7.96 6.42 5.51 5.17 4.88 4.42 4.07 3.78 3.56 3.42 3.34 2.66 2.48 2.40 2.34 2.26 2.15 2.14 2.08 2.03 1.98 1.90 1.78 -

Mechanical Minimum bending radius a) single bending (cm) b) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range - Storage - Installation - Operation Maximum length per hoisting grip (m) Maximum hanger spacing Flat plate crush resistance (kg/mm) Bending moment (Nm) Approximate weight[2] (kg/km) 20 35 240 -70 to +85 C -40 to +60 C -55 to +85 C 70 1.4 2.4 30 803 / 889

[1] a = 0.0783 b = 0.00031 () = a . f + b . f [dB/100m] [2] Standard PE jacket / HLFR jacket [3] Nominal values [4] Ambient temperature = 40 C; Temperature of inner conductor = 100 C; VSWR = 1.0; no solar loading

24

Kabelwerk Eupen AG

1-1/4 A

NF50V114N1

716FV114N1

CONNECTORS & TOOL


Reference
716MV114N1 716FV114N1 716MA114M 716FA114M NM50V114N1 NF50V114N1 SPTC50AV114M Inner ring Outer ring Spring Cutting knife Peeling knife SIL-744 90ml SIL-744 310 ml

Description
7-16 DIN male, O-Ring 7-16 DIN female, O-Ring 7-16 DIN male, Sealant injection 7-16 DIN female, Sealant injection N male, O-Ring N female, O-Ring Cable preparation tool Spare parts for cable preparation tool (Refer to installation instructions of the tool)

Specification of
Electrical

N-connectors
50 35 5 2.5 1 >128

7-16 connectors
50 35* 10 4 2.7 >128

Sealant for connectors using sealant injection Sealant for connectors using sealant injection

Nominal impedance () Return loss at 3 GHz (dB) Insulation resistance (G) Test voltage (at sea level) (kV rms, 50 Hz) Working voltage (at sea level) (kV rms, 50 Hz) Screening effectiveness up to 1 GHz (dB) Outer contact resistance (m) Inner contact resistance (m) PIM ratio (2 x 20 W carrier) (dBc) Mechanical

1.0 1.0 -155 (Typical -163)

Rem.: Sealant for connectors using the sealant injection method must be purchased separately. EIA connectors available on request.

Torque on coupling nut (Nm) Cable retention (N) Environmental Temperature range (C) Degree of protection (humidity) Materials External parts Outer contact Inner contact Dielectric Gaskets * sealant injection type: 34

8 >1000

30

-40 to +85 IP67/IP68 (mated connectors)

Passivated silver plated or electroless nickel plated brass Passivated silver plated brass Passivated silver plated high-strength copper alloy and brass TPX High quality silicone

SPTC50AV114M

ACCESSORIES
Description
Grounding clamp with parallel outlet Fixing clamps Additional weatherproofing Lace-up hoisting grip Pre-laced hoisting grip

Reference
GCS114PAR see page 35 see page 41 HG-114 HG-114-L see page 37 Kabelwerk Eupen AG 25 GCS114PAR

1-5/8A
Ultra Low Loss

STANDARD
Cable type : Reference :

5438 A
5438 A EC7-50-A

FLAME RETARDANT
Cable type : Reference :

HLFR
5438 A-HLFR EC7-50-A-FR

Cable with standard UV resistant PE jacket, halogen free according to IEC 60754

Cable with UV resistant, halogen free, low smoke, flame retardant jacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3 Cat. C and IEC 61034-1+2

CHARACTERISTICS
Construction Inner conductor Material Diameter (mm) Dielectric Material Diameter (mm) Outer conductor Material Diameter (mm) Jacket Material Thickness (mm) Diameter (mm) corrugated copper tube 17.7 gas-injected cellular polyethylene 43.0 corrugated copper tube 46.6 black polyethylene 1.7 50.0 Electrical Characteristic impedance () Nominal capacity (pF/m) Relative propagation velocity (%) Inductance (H/m) DC-resistance at 20 C - inner conductor (/km) - outer conductor (/km) RF peak voltage (kV) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (M.km) Attenuation[1] and power rating Frequency Attenuation at 20 C [3] (MHz) (dB/100m) 10 0.20 20 0.29 30 0.36 80 0.59 100 0.67 150 0.82 200 0.96 300 1.18 400 1.38 450 1.47 500 1.56 600 1.72 700 1.87 800 2.01 894 2.14 960 2.23 1000 2.28 1500 2.86 1700 3.07 1800 3.17 1880 3.25 2000 3.37 2170 3.53 2200 3.56 2300 3.65 2400 3.74 2500 3.83 2700 4.01 3000 4000 6000 50 1 75 89 0.187 1.37 0.5 5.5 302 2.8 >>5000 Mean power rating [4] (kW) 49.42 34.76 28.27 17.09 15.22 12.32 10.60 8.55 7.33 6.88 6.50 5.89 5.41 5.03 4.73 4.55 4.45 3.54 3.30 3.19 3.12 3.01 2.87 2.85 2.77 2.71 2.64 2.53 -

Mechanical Minimum bending radius a) single bending (cm) b) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range - Storage - Installation - Operation Maximum length per hoisting grip (m) Maximum hanger spacing Flat plate crush resistance (kg/mm) Bending moment (Nm) Approximate weight[2] (kg/km) 20 40 250 -70 to +85 C -40 to +60 C -55 to +85 C 70 1.5 2.4 42 1019 / 1131

[1] a = 0.064 b = 0.000253 () = a . f + b . f [dB/100m] [2] Standard PE jacket / HLFR jacket [3] Nominal values [4] Ambient temperature = 40 C; Temperature of inner conductor = 100 C; VSWR = 1.0; no solar loading

26

Kabelwerk Eupen AG

1-5/8A

NF50V158N1

716MV158N1

CONNECTORS & TOOL


Reference
716MV158N1 716FV158N1 716MA158MPA 716FA158MPA NM50V158N1 NF50V158N1 SPTC50AV158M Inner ring Outer ring Spring Cutting knife Peeling knife SIL-744 90 ml SIL-744 310 ml

Description
7-16 DIN male, O-Ring 7-16 DIN female, O-Ring 7-16 DIN male, Sealant injection 7-16 DIN female, Sealant injection N male, O-Ring N female, O-Ring Cable preparation tool Spare parts for cable preparation tool (Refer to installation instructions of the tool)

Specification of
Electrical

N-connectors
50 35 5 2.5 1 >128

7-16 connectors
50 35* 10 4 2.7 >128

Sealant for connectors using sealant injection Sealant for connectors using sealant injection

Nominal impedance () Return loss at 2.7 GHz (dB) Insulation resistance (G) Test voltage (at sea level) (kV rms, 50 Hz) Working voltage (at sea level) (kV rms, 50 Hz) Screening effectiveness up to 1 GHz (dB) Outer contact resistance (m) Inner contact resistance (m) PIM ratio (2 x 20 W carrier) (dBc) Mechanical

1.0 1.0 -155 (Typical -163)

Rem.: Sealant for connectors using the sealant injection method must be purchased separately. EIA connectors available on request.

Torque on coupling nut (Nm) Cable retention (N) Environmental Temperature range (C) Degree of protection (humidity) Materials External parts Outer contact Inner contact Dielectric Gaskets * sealant injection type: 34

8 >1500

30

-40 to +85 IP67/IP68 (mated connectors)

Passivated silver plated or electroless nickel plated brass Passivated silver plated brass Passivated silver plated high-strength copper alloy and brass PTFE TPX High quality silicone

SPTC50AV158M

ACCESSORIES
Description
Grounding clamps with parallel outlet Fixing clamps Additional weatherproofing Lace-up hoisting grip Pre-laced hoisting grip

Reference
GCS158PAR see page 35 see page 41 HG-158 HG-158-L see page 37 Kabelwerk Eupen AG 27 GCS158PAR

2-1/4

STANDARD
Cable type : Reference :

5528
5528 EC12-50

FLAME RETARDANT
Cable type : Reference :

HLFR
5528-HLFR EC12-50-FR

Cable with standard UV resistant PE jacket, halogen free according to IEC 60754

Cable with UV resistant, halogen free, low smoke, flame retardant jacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3 Cat. C and IEC 61034-1+2

CHARACTERISTICS
Construction Inner conductor Material Diameter (mm) Dielectric Material Diameter (mm) Outer conductor Material Diameter (mm) Jacket Material Thickness (mm) Diameter (mm) corrugated copper tube 21.0 gas-injected cellular polyethylene 52.0 corrugated copper tube 56.0 black polyethylene 2.0 60.0 Electrical Characteristic impedance () Nominal capacity (pF/m) Relative propagation velocity (%) Inductance (H/m) DC-resistance at 20 C - inner conductor (/km) - outer conductor (/km) RF peak voltage (kV) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (M.km) Attenuation[1] and power rating Frequency Attenuation at 20 C [3] (MHz) (dB/100m) 10 0.16 20 0.23 30 0.29 80 0.49 100 0.55 150 0.68 200 0.80 300 1.01 400 1.19 450 1.27 500 1.35 600 1.50 700 1.65 800 1.78 894 1.91 960 1.99 1000 2.04 1500 2.63 1700 2.84 1800 2.95 1880 3.03 2000 3.15 2170 3.32 2200 3.35 2300 2400 2500 3000 4000 6000 50 1 76 88 0.189 0.55 0.25 6.8 462 2.3 >>5000 Mean power rating [4] (kW) 72.19 50.47 40.86 24.30 21.55 17.28 14.74 11.74 9.96 9.30 8.75 7.86 7.18 6.62 6.20 5.93 5.79 4.50 4.16 4.01 3.90 3.75 3.56 3.53 -

Mechanical Minimum bending radius a) single bending (cm) b) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range - Storage - Installation - Operation Maximum length per hoisting grip (m) Maximum hanger spacing Flat Plate Crush resistance (kg/mm) Bending moment (kg/km) Approximate weight[2] (kg/km) 25 55 300 -70 to +85 C -40 to +60 C -55 to +85 C 70 1.8 4.8 90 1838

[1] a = 0.05035 b = 0.00045 () = a . f + b . f [dB/100m] [2] Standard PE jacket [3] Nominal values [4] Ambient temperature = 40 C; Temperature of inner conductor = 100 C; VSWR = 1.0; no solar loading

28

Kabelwerk Eupen AG

2-1/4

NF50V214

716MV214

CONNECTORS & TOOL


Reference 716MV214 716FV214 NM50V214 NF50V214 SG 214 SIL-744 90ml SIL-744 310 ml

Description
7-16 DIN male, O-Ring 7-16 DIN female, O-Ring N male, O-Ring N female, O-Ring Saw guide Sealant for connectors using sealant injection Sealant for connectors using sealant injection

Specification of
Electrical

N-connectors
50 32 5 2.5 1 >128 0.5 1

7-16 connectors
50 32 10 4 2.7 >128 0.5 1

Rem.: Sealant for connectors using the sealant injection method must be purchased separately.

Nominal impedance () Return loss at 2.3 GHz (dB) Insulation resistance (G) Test voltage (at sea level) (kV rms, 50 Hz) Working voltage (at sea level) (kV rms, 50 Hz) Screening effectiveness up to 1 GHz (dB) Outer contact resistance (m) Inner contact resistance (m) PIM ratio (2 x 20 W carrier) (dBc) Mechanical Torque on coupling nut (Nm) Cable retention (N) Environmental Temperature range (C) Degree of protection (humidity) Materials External parts Outer contact Inner contact Dielectric Gaskets

-155 (Typical -163)

8 >400

30 >1000

-40 to +85 IP67/IP68 (mated connectors)

SG214

Passivated silver plated or electroless nickel plated brass Passivated silver plated brass Passivated silver plated high-strength copper alloy and brass TPX/PTFE High quality silicone

ACCESSORIES
Type Reference Description
GCS214PAR see page 35 see page 41 GCS214PAR

Grounding clamp with parallel outlet Fixing clamps Additional Weatherproofing

Kabelwerk Eupen AG

29

SOLDERED JUMPER CABLES


EUPEN offers jumper cables with 1/2 Hiflex cable (5092 / EC4-50-HF) or 1/2 standard cable (5128 / EC4-50) with soldered DIN 7-16 or N type straight and right angle connectors. All metal contact parts are silver plated. They are designed for watertight applications and optimised jumper cable performances.

Features
excellent return loss values very low bending radius: 30 mm for 1/2 Hiflex (5092) 70 mm for 1/2 standard (5128) for single bending (125 mm for repeated bendings) very low level of 3rd order intermodulation products easy, fast and reliable installation water tightness according to IP67/IP68 (mated connectors) longitudinal water tightness is provided by the special connector design (O-Ring in connector head) the overmolding of the connector provides an additional mechanical protection

Product reference
EC4-vv-S-www-XYZXYZ EC4 = 1/2 cable (5128) vv = HF for Hiflex (5092) S = soldered connector www = length in cm X = D for DIN 7-16 type connector N for N type connector Y = M for male or F for female Z = L for right angle connector

Marking
Manufacturer EUPEN Week & Year of Production Product Ref.: for ex.: EC4-HF-S-200-DMDM Torque Product Nr. EUPEN Serial Number

30

Kabelwerk Eupen AG

Jumper cables

Technical data
Cable type Electrical Nominal impedance [] Frequency range [MHz] PIM ratio (2 x 20 W carrier) [dBc] Attenuation per m at 20 C [dB] - without connectors* 960 MHz 1880 MHz 2200 MHz 2600 MHz RF Voltage rating (Peak) [V] Relative propagation velocity [%] Mechanical Minimum bending radius [mm] - single - repeated Connector torque (nominal) [Nm] - DIN 7-16 connector - N type connector Environmental Temperature range [C] - installation - operating Protection against water ingress - Longitudinal water tightness General environmental RoHS compliance (EU Directive 2002/95/EC) Maximum power rating [W] Connector 1 Connector 2 7-16 7-16 7-16 N N N Return loss [dB] (VSWR)** Connector 1 Connector 2 7-16 7-16 Reference ...-DyzDyz ...-DyzNyz ...-NyzNyz Reference ...-DyDy ...-DyDML ...-DMLDML ...-DyNy ...-DyNML ...-DMLNy ...-DMLNML ...-NyNy ...-NyNML ...-NMLNML 800 - 1000 MHz 650 600 600 800 - 1000 MHz > 32 (< 1.05) > 30 (< 1.065) > 28 (< 1.08) > 32 (< 1.05) > 30 (< 1.065) > 30 (< 1.065) > 28 (< 1.08) > 30 (< 1.065) > 29 (< 1.07) > 28 (< 1.08) EC4-50-HF (5092) 1/2-HIFLEX EC4-50 (5128) 1/2

50 1 10 - 2700 -155 (Typical -163) 0.106 0.151 0.170 0.187 1130 82 0.071 0.103 0.113 0.123 1600 88

30 30 28 12

70 125 28 12

-40 to +60 -55 to +85 Water tightness acc. to IP 68 (0.5 bar / 24 h) Two O-rings in the DIN 7-16 connector head Corrosion and UV resistant YES 1700 - 2700 MHz 350 300 300 1700 - 2700 MHz > 29 (< 1.075) > 28 (< 1.08) > 26 (< 1.10) > 29 (< 1.075) > 28 (< 1.08) > 28 (< 1.08) > 26 (< 1,10) > 27 (< 1.09) > 27 (< 1.09) > 26 (< 1.10) 800 - 1000 MHz 800 600 600 800 - 1000 MHz > 32 (< 1.05) > 32 (< 1.05) > 30 (< 1.065) 1700 - 2700 MHz 450 300 300 1700 - 2700 MHz > 29 (< 1.075) > 29 (< 1.075) > 27 (< 1.09) -

7-16

* Typical values without connectors, the typical connector attenuation (2 connectors) is less than 0.02 [dB] ** These values are given for a length of the jumper up to 10 meters.

Kabelwerk Eupen AG

31

ACCESSORIES FOR CABLES


1. adapters
Eupen offers a wide range of inside-series and interseries 7-16 DIN and N type adapters designed in premium and precision models.

Features
Low reflection coefficient up to 2.7 GHz Low PIM (-163dBc) high contact force realized with inner contacts made in a high-strength copper alloy Silver plated Watertight (IP67/IP68) Corrosion resistant

A. premium adapters
Description Premium adapters are characterised by a minimum Return loss of -34 dB up to 2.7 GHz.
N male to 7-16 male N female to 7-16 male N male to 7-16 female N female to 7-16 female N male to N female N male to N male N female to N female 7-16 male to 7-16 female 7-16 female to 7-16 female 7-16 male to 7-16 male

Reference
AD50NM716M AD50NF716M AD50NM716F AD50NF716F AD50NMF AD50NMM AD50NFF AD50716MF AD50716FF AD50716MM

B. precision adapters
Description For applications where high electrical performances and very low return loss are requested, and where high precision measurement equipment is requested - such as field test application in the cellular communication - we offer high precision adaptors featuring lowest return loss with guaranteed minimum -40 dB up to 2.7 GHz.
N male to 7-16 male N female to 7-16 male N male to 7-16 female N female to 7-16 female 7-16 female to 7-16 female 7-16 male to 7-16 male

Reference
PRAD50NM716M PRAD50NF716M PRAD50NM716F PRAD50NF716F PRAD50716FF PRAD50716MM

32

Kabelwerk Eupen AG

Accessories for cables

2. preset torque wrench selection guide


The torque wrenches emit an audible click when the specified torque is reached. Proper tightening ensures water-tightness and prevents loosening from vibration.

A. blue wrench handles for connector back nuts


Connector Size mm (in)
1/2 1/2-Hiflex 7/8 & 7/8-Hiflex 1-1/4 & 1-1/4-Hiflex 1-5/8 2-1/4 19 (3/4) 19 (3/4) 30 (1-3/16) 43 (1-11/16) 58 (2-1/4) 67 (2-5/8)

Head thickness mm
7 7 12 13 13 13

Torque value Nm (ft-lb)


20 (15) 27 (20) 30 (22) 40 (29) 50 (37) 50 (37)

Reference

TQ-34-F15 TQ-34-F20 TQ-30MM-F22 TQ-11116-F29 TQ-214-F37 TQ-258-F37*

Important: Hold connector body fixed while turning back nut with torque wrench.
* only available on request

B. red wrench handles for connector interfaces


Connector Size mm (in)
7-16 DIN coupling nut 32 (1-1/4)

Head thickness mm
13

Torque value Nm (ft-lb)


25 (18)

Reference

TQ-114-F18-M

Kabelwerk Eupen AG

33

3. grounding clamps
A. grounding clamps GCS
The optimal grounding of the transmission line antenna to base station is a very weak point. In order to guarantee the best grounding we recommend the use of the EUPEN grounding clamps in order to ground the coaxial outer conductor to the antenna tower or ground wire. The main features of the Eupen grounding clamps are:
GCS grounding clamp with parallel outlet

GCS grounding clamp with 90 outlet

Ultra quick and easy installation No loose parts Lightning resistant to 100kA lightning current (wave type 10/350 s) Very low contact resistance < 1mOhm Waterproof according IP67 / IP68 without additional tape or sealant Corrosion resistant Reusable

GROUNDING CLAMPS
Reference
Cable size Outlet Cable cut (mm)

GCS14
1/4 90 24

GCS38
3/8 90 20

GCS12X
1/2 Hiflex 90 24

GCS12PAR
1/2 parallel 25

GCS78PAR

GCS114PAR

GCS158PAR GCS214PAR
1-5/8A parallel 30 2-1/4 parallel 30

7/8A & 7/8 Hiflex 1-1/4A & 1-1/4 Hiflex parallel parallel 21 26

For further details please refer to technical specifications.

B. connector grounding kit CGC 12-158


Description
Stainless steel connector grounding clamp 60 cm lead with attachment lug and stainless steel M6 Allen screw, washer and nut.

Features
Fast, easy and reliable installation Low contact resistance Corrosion resistant stainless steel material Reusable Only one model for all the connector sizes from 1/2 to 1-5/8

34

Kabelwerk Eupen AG

Accessories for cables

4. fixing clamps
A. eucatecTM rf cable clamps with lock nut
Features
High durability given by non-corrosive metal components of V2A stainless steel and calibrated saddles from ultraviolet and aging resistant polyamide Mountable at C-profile rails usual in radio systems as well as flat sections to a maximum of 25 mm thickness and tubes up to a diameter of 25 mm (according to clamp type) Easy handling; the cable clamps (single type) consist of merely two elements Inlet design with crotchet on both sides to retain the saddles in the clamp while fixing the cable Protection of the cable against a possible harm through the tensioning screw is ensured since the tensioning screw is combined firmly with the polyamide shell Extra-secure hold is achieved by the use of a look nut All EUCATEC Cable Clamps are available in single, double or triple version Also available without look nut
ECC-C-2x78-LN

Suitable profile types


Standard C-Profile Flat sections Pipes Right angle
R25 8 mm 40 or 50 mm 9 mm R11

Please contact us for a comprehensive list of the available versions.

Kabelwerk Eupen AG

ECC-U11-...-LN

ECC-U-...-LN

ECC-C-...-LN

ECC-A-...-LN

ECC-F-...-LN

35

B. stainless steel clamp system

EU-SH78L EU-CH78NH

snap-in hangers

clip hangers

Reference
Snap-In Clip Hangers Material :

1/2
EU-SH12L EU-CH12NH

7/8
EU-SH78L EU-CH78NH

1-1/4
EU-SH114L EU-CH114NH

1-5/8
EU-SH158L EU-CH158NH

2-1/4
EU-SH214L

Stainless steel

OPTION: Angle Adapter for snap-in or clip hangers Description


Angle Adapter

Reference
EU-AA-SL

C. orientable stainless steel spring clamp


For mainting on flat plate or angle No additional hardware required Orientable

Reference
Spring Clamp

1/2
EU-ES9016

7/8
EU-ES9028

1-1/4
EU-ES9040

1-5/8
EU-ES9040

Other specific clamps are available on request

36

Kabelwerk Eupen AG

Accessories for cables

5. hoisting grips
We offer two types of hoisting grips: the lace-up one and the pre-laced one. Please refer to the table below. Hoisting grips are used to raise the cable up the tower. They can be tied off as a permanent support. Use one hoisting grip for every 60 m cable length. The hoisting grips are manufactured from high-grade tin coated bronze to provide highest corrosion resistance.

HOISTING GRIPS
Reference
Lace-up type Pre-laced type

1/2
HG-12 HG-12-L

7/8
HG-78 HG-78-L

1-1/4
HG-114 HG-114-L

1-5/8
HG-158 HG-158-L

6. sealant sil-744 for connectors with sealant injection


In outdoor installations the Connector/Cable interface is very sensitive to water ingress. The Sealant injection waterproofing method creates a quick, secure seal between the back nut and jacket / outer conductor. The SIL-744 is recommended to be used with all EUPEN connectors where sealant injection is required. The SIL-744 is supplied either in a box with a 90 ml tube of sealant including connector adapter and key or in a tube containing 310 ml. With one tube the following quantities of connectors can be sealed:

SIL-744
Reference
with 90 ml tube with 310 ml tube

3/8
26...30 90...103

1/2
20...25 69...86

7/8
13...15 44...51

1-1/4
7...9 24...31

1-5/8
4...5 13...17

2-1/4
3...4 10...13

Kabelwerk Eupen AG

37

7. eucaseal
The Eucaseal is an additional and optional gel closure sealing system that provides a reliable sealing of coaxial connectors used at the transition between: jumper and antennas or the electric devices like TMAS .... jumper and feeder cables exposed to the outside environment

ES-12-114

Benefit
The housing contains an innovative gel material and provides an efficient moisture block. The ease of installation and the long-term protection makes it a reliable and cost effictive solution.

Features
Reliable protection over a wide temperature range: -30 C to 60 C Wraparound and no disconnection of the connector Quick and easy to install Easily removable and re-usable Gel material provides an effective barrier against ingress of water and other contaminants - IP 68 acc. EN 60529 No tape, no mastics or tools required for installation and removal UV resistant Tested under extremely severe conditions, vibrations (acc. IEC 60068-2-6 Test Fc) and temperature cycles (acc. IEC 60068-2-14 Test Nb) Protection against excessive bending of the cable.

ES-12-78

ES-12-114

38

Kabelwerk Eupen AG

Accessories for cables

EUCASEAL
Application 1/2 jumper to antenna or box
ES-12-BOX 1/2 & 1/2 Hiflex

1/2 jumper to 7/8 feeder


ES-12-78 1/2 & 1/2 Hiflex to 7/8A or 7/8 Hiflex N or 7-16

1/2 jumper to 1-1/4 feeder


ES-12-114 1/2 & 1/2 Hiflex to 1-1/4A or 1-1/4 Hiflex N or 7-16

1/2 jumper to 1-5/8 feeder


ES-12-158 1/2 & 1/2 Hiflex to 1-5/8A N or 7-16

Reference Cable type

Connector type

only DIN 7-16 - max. length 60 mm - max. body diameter 26,6 mm - nominal distance between panel connectors 45 mm

Available in black and grey For further details please refer to technical specifications.

ES-12-BOX

ES-12-BOX

Kabelwerk Eupen AG

39

8. lightning arresters
Our lightning arresters offer an additional protection for the BTS against lightning damages and can be used in wideband applications from 800 to 2500 MHz. In addition to the 1/4 wave lightning arrester, an hybrid version with a replaceable gas capsule is available, which permits the transmission of DC-voltage.

Features
Quick and easy to install Basic range from 800 to 2500 MHz Arrester method: 1/4 Wave

Quarter wave lightning arrester* ref: EU-LA-QW-800-2500-DMDF

Technical Data **
Impedance: 50 Ohm Insertion loss: < 0.1 dB Return Loss (VSWR): < 1.15 Surge current handling capability at least 20 kA (8/20 S) Max. power: 300W ***

Reference
for ex.: EU-LA-QW-800-2500-DM-DF * Bulkhead version available on request ** For further details please refer to technical specifications *** 150 W for version with gas-tube

Hybrid gas-tube +1/4 wave lightning arrester ref: EU-LA-QWG230-800-2500-DM-DFP

40

Kabelwerk Eupen AG

Accessories for cables

9. weatherproofing tape kit


If additional weatherproofing is required, it can be achieved with appropriate adhesive tapes wrapped around the cable/connector interface. EUPEN supplies a weatherproofing tape kit for additional protection of connector, cable and jumper junctions.

Features
Universal weatherproofing Special weather resistant PVC-Tape Suitable for difficult weather conditions

TECHNICAL DATA
Butyl mastic tape
Material Color Length (m) Width (mm) Thickness (mm) self-fusing butyl (lead free) black 2 65 2.5

Adhesive all-weather PVC-tape


Backing Color Length (m) Width Thickness (mm) Tensile strength (N/cm) Elongation (%) Temperature range (C) Resistance to flame propagation Dielectric strength (kV/mm) PVC (lead free) black 20 25 0.2 20 200 -40 to +105 self-extinguishing 40

The following table indicates the quantity of connectors or splices which can be sealed with 1 kit:
Cable/Connector
Single connector Splice

1/4 & 3/8


10 6

1/2 & 1/2X


9 5

7/8
7 4

1-1/4
5 3

1-5/8
3 2

PRODUCT OVERVIEW
Product Reference
Weatherproofing tape kit

Contents
1 roll of self-fusing butyl tape (65 mm x 2 m) 1 roll of black PVC tape (25 mm x 20 m)

Kabelwerk Eupen AG

41

CABLE PACKING AND HANDLING INFORMATION


The coaxial cable will be supplied on wooden drums made of planed wooden boards or plywood. In order to protect the cable during transportation and storage, the drums will be battened with wooden boards nailed on the flanges. The drums are provided with a label containing cable information as cable type, cable length and production batch (see label on right). The drums can be impregnated on request. The standard drum sizes used for the different cable types are shown in the table below.

w A W

Most used drums per cable type[1]:


Cable type Drum type Usual length
(m) EC1-50 (5062) EC1-50 (5062) EC1-50-HF (5042) EC1-50-HF (5042) EC2-50 (5088) EC2-50 (5088) EC4-50 (5128) EC4-50 (5128) EC4-50 (5128) EC4-50-HF (5092) EC4-50-HF (5092) EC4.5-50 (5168) EC4.5-50 (5168) EC5-50-A (5228A) EC5-50-A (5228A) EC5-50-HF (5228X) EC5-50-HF (5228X) EC6-50-A (5328A) EC6-50-A (5328A) EC6-50-A (5328A) EC6-50-A (5328A) EC6-50-HF (5328X) EC6-50-HF (5328X) EC6-50-HF (5328X) EC6-50-HF (5328X) EC7-50-A (5438A) EC7-50-A (5438A) EC7-50-A (5438A) EC12-50 (5528) EC12-50 (5528) 1/4 1/4 1/4 Hiflex 1/4 Hiflex 3/8 3/8 1/2 1/2 1/2 1/2 Hiflex 1/2 Hiflex 5/8 5/8 7/8A 7/8A 7/8 Hiflex 7/8 Hiflex 1-1/4 A 1-1/4 A 1-1/4 A 1-1/4 A 1-1/4 Hiflex 1-1/4 Hiflex 1-1/4 Hiflex 1-1/4 Hiflex 1-5/8A 1-5/8A 1-5/8A 2-1/4 2-1/4 HE 07 HE 08 HF HE 07 HE 08 HF HE 07 HE 08 HF HE 07 HE 08 HF HE 12 HE 07 HE 08 HF HE 12 HE 13 HE 12 HE 13 HE 12 HE 13 HF 17S HF 17B HF 18 HF 20 HF 17S HF 17B HF 18 HF 20 HF 17S HF 18 HF 20 HF 17B HF 20 up to 650 from 650 to 1350 up to 1200 from 1200 to 2150 up to 450 from 450 to 900 up to 250 from 250 to 500 from 500 to 1500 up to 330 from 330 to 750 up to 800 from 800 to 1300 up to 500 from 500 to 900 up to 500 from 500 to 900 up to 500 from 500 to 700 from 700 to 900 from 900 to 1300 up to 500 from 500 to 700 from 700 to 900 from 900 to 1300 up to 270 from 270 to 500 from 500 to 850 up to 250 from 250 to 550

Outer diam.[2] D
(cm) 70 80 70 80 70 80 70 80 120 70 80 120 130 120 130 120 130 170 170 180 200 170 170 180 200 170 180 200 170 200

Drum diam. d
(cm) 40 40 40 40 40 40 40 40 40 40 40 40 47 40 47 40 47 90 90 90 90 90 90 90 90 90 90 90 90 90

[1] These combinations cable/length/drum are examples of the most common cases. Others are possible under request. [2] battened + 5 cm [3] Depending on the humidity of the wood, drum weights can vary greatly! [4] Standard PE jacket

42

Kabelwerk Eupen AG

Packing information

Drum label

Outer width W
(cm) 42 53 42 53 42 53 42 53 53 42 53 53 76 53 76 53 76 74 102 102 116 74 102 102 116 74 102 116 102 116

Inner width w
(cm) 40 50 40 50 40 50 40 50 49 40 50 49 72 49 72 49 72 64 92 92 104 64 92 92 104 64 92 104 92 104

Shaft hole A
(cm) 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 8.0 6.5 6.5 8.0 8.0 8.0 8.0 8.0 8.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0

Freight volume Approx. drum weight Approx. drum/battened drum drum/battened drum[3] cable weight[4]
(m3) 0.20 / 0.34 / 0.38 0.20 / 0.34 / 0.38 0.20 / 0.34 / 0.38 0.20 / 0.34 / 0.38 0.77 / 0.82 0.20 / 0.34 / 0.38 0.77 / 0.82 1.28 / 1.36 0.77 / 0.82 1.28 / 1.36 0.77 / 0.82 1.28 / 1.36 2.14 / 2.24 2.95 / 3.12 3.30 / 3.49 4.64 / 4.87 2.14 / 2.24 2.95 / 3.12 3.30 / 3.49 4.64 / 4.87 2.14 / 2.24 3.30 / 3.49 4.64 / 4.87 2.95 / 3.12 4.64 / 4.87 (kg) 7/16 / 35 7/16 / 35 7/16 / 35 7/16 / 35 25 / 60 7/16 / 35 25 / 60 40 / 90 25 / 60 40 / 90 25 / 60 40 / 90 150 / 215 175 / 250 200 / 300 280 / 415 150 / 215 175 / 250 200 / 300 280 / 415 150 / 215 200 / 300 280 / 415 175 / 250 280 / 415 (kg/km) 111 111 83 83 146 146 231 231 231 193 193 345 345 436 436 475 475 803 803 803 803 754 754 754 754 1019 1019 1019 1838 1838

Kabelwerk Eupen AG

43

Malmedyer Str. 9 - 4700 EUPEN - BELGIUM


Tel.: +32(0)87.59.70.00 http://www.eupen.com Fax: +32(0)87.59.71.00 e-mail:info@eupen.com
01/2012 - 2000 pc (K)

ISO Certied Company

You might also like