You are on page 1of 2

CP

Sigma CP
Conventional
Fire Alarm
Control Panels
Fully compliant with & tested
to BS EN54-2 and BS EN54-4
2-wire and standard
versions in 2, 4 or 8 zones
Compatible for use on
BS5839: Part 1: 2002
installations
2-wire repeaters and
ancillary boards
Fully programmable using
simple menu options
Simple, single board
construction
Installer friendly
Compatible with
wide range of
detection devices
Two monitored
sounder outputs
3 Amp power supply
Auxiliary power output
Two, four and eight
zone, 2-wire or standard,
programmable fire
control panels
conventional detection
systems requiring high
performance and quality.
The S igma CP range consists of a series of
conventional f ire alarm control panels designed in
accordance with European standards BS EN54-2
and BS EN54-4 Fire D etection and Fire A larm
systems - Control and Indicating Equipment.
The range consists o f 2, 4 and 8 zone control
panels. A ll control panels are available in t wo
versions:
Sigma K11 r ange in which detectors and call
points are wired on separate circuits t o
sounders (two sounder circuits are provided).
Sigma T11 r ange in w hich detectors, c all
points and sounders are wired to the same pair
of cables. Commonly referred to as a two-wire
system.
Wiring sounders to the detection circuits eliminates
the need to i nstall s ounder c ircuit cables and also
offers the ability t o provide zoned or t wo stage
sounder operation.
All control panels have an integral, mains powered
battery charger and power s upply designed in
accordance with the requirements of BS EN54-4.
Features Product Overview
Adjustable sounder delay time
Sounder configuration options
Zonal sounder delay detectors only
Zonal sounder delay call points only
Coincidence input selection
I.S Barrier selection by zone
Short circuit fire by zone
Non latching zones
Silent zones
Zone input delay
General panel configuration
BS EN54-2
BS EN54-4
KM 73505
Sigma
Model No. K11080M2
Page 36
DS37.05.2005
Technical
Specifications
The manufacturer reserves the right to amend specifications without prior notice
Size
Construction
Colour

Supply voltage
Mains supply fuse
Power supply DC rating
Maximum battery size
Fault contact rating
Local fire contact rating
Fire contact rating
Sounder output rating
Detection zone current
Detection zone
end of line resistor
Sounder output
end of line resistor
Cable capacity
Operating temperature
Operating humidity
385mm(W) x 310mm(H) x 92mm(D)
1.2mm mild steel
BS 00 A 05 (grey texture) - lid & box
Ral 7047 (light grey) - controls plate
230V AC (+10%/-15%)
1.6 Amp 250V
24V 3 Amps
7Ah 12V (2 per panel)
30V DC 1 Amp
30V DC 1 Amp
30V DC 1 Amp
0.5A per output (max 1.6A over all outputs)
1.6 milliamps
6k8 5%

10k 5%

-
-
-

-
-
-
-
-
-
-
-
-
-

-

-
-
-
Certificate No. FM 32987
BS EN ISO 9001: 2000
Certificate No. 360
BS EN ISO 9001: 2000
Panels
Product
Code

K11020M2
K11040M2
K11080M2
T11020M2
T11040M2
T11080M2
Description


2 zone control panel
4 zone control panel
8 zone control panel
2 zone, 2 wire panel
4 zone, 2 wire panel
8 zone, 2 wire panel
Standby
Current

0.065 Amps
0.075 Amps
0.093 Amps
0.065 Amps
0.075 Amps
0.093 Amps
Alarm
Current

0.1 Amps
0.21 Amps
0.55 Amps
0.15 Amps
0.3 Amps
0.63 Amps
Page 37
8
7
6
5
4
3
2
1
ModeI: k11080M2
S N54-2 : 1998
S N54-4 : 1998
Fire AIarm ControI
kM 73505
Zone Cbart CeneraI System Status
DisabIement
Sounder FauIt/
8 7 6 5
4 3 2 1
SystemMode
(+1) (+10)
Zone FauIt/7est/DisabIement
Zone FauIt/7est/DisabIement
nter SeIect Mode Reset
nabIe ControI
Fire
Fire In Zone
Fire In Zone
7est Mode Dn
DeIay Dn
Power Dn
WarningSiIenced
AIarm/FauI t
Power FauIt
DisabIement
CeneraI
System FauIt
CeneraI FauIt
7est
Lamp
AIarm
SiIence/Sound AIarm/FauIt
Warning SiIence
385 90