Professional Documents
Culture Documents
RKB
Casing Collar Above Wellhead = Casing Height Above RKB = Length of Landing Joint (s)= RKB to WHF =
CASING CHECK 135.77 Total pipe left out of string, ft 13,433.38 Total pipe tallied, ft 13,297.61 Total pipe run, ft Good News Casing Check Status Casing Check: (pipe run + pipe left out) = to the amount tallied. ESTIMATED PSI WHEN PLUG DOWN Column Length of Mud 7,368 Total Hydrostatic PSI Annulus 8,410 Total Hydrostatic PSI Casing 7,105 * Final Surface PSI 1,305
SPACER LEAD CEMENT
CALCULATED ANN VEL FOR JOB Rate, bpm AV, fpm Pump, spm 10 179 85 15 269 128
Enter bpm to calculate an AV and PUMP spm to circulate and cement this casing string. SUGGESTED RATES ... CIRCULATION RATE: SAME AS MAX AV WHEN DRILLING THIS SECTION OF HOLE. DISPLACEMENT RATE: @ 1-1/2 TIMES THE CIRCULATION RATE. BUMP PLUG: @ 1/2 CIRCULATION RATE.
Type Cement 50/50 Posmix Length, ft 4,000 Sxs To Mix 1835 Additive 1 3% D20 TAIL CEMENT Additive 2 .045 gps D81 Type Cmt. Class H Additive 3 .2% D-46 Length, ft 1,000 Additive 4 Sxs To Mix 1100 Density, ppg 14.0 Additive 1 .045 gps D81 Yield, ft/sx 1.29 Additive 2 .2% D46 Mix Water, gps 5.95 Additive 3 Thick Time, hrs 5.0 Additive 4 * Final pressure neglects Density, ppg 16.4 friction pressure, assumes a Yield, ft/sx 1.07 gauge hole and full mud Mix Water, gps 4.36 returns during job. Thick Time, hrs 3.0 CENTRALIZERS Starting Jt. # Ending Jt. # 241 240 239 237
RUNNING SEQUENCE
(ENTER RUN ORDER AND OTHER INSTRUCTIONS FOR STRING)
1. 2. 3. 4. 5. 6 7
Davis Lynch Float shoe Joints 300 &299 Davis Lynch Float collar. Run Jts. 298 to 112 Skip #111
Thread Lock FC, FS and connections in between. Check FC and FS for circulation.
EST. TOC = 8264'
STRING COMPONENTS
Used Per Jt. 2 1 Quantity 4 3
Length of Casing = 13207.32' Length of Float Collar = 1.50' Length of Shoe Joint(s) = 90.29' Length of Float Shoe = 1.80' Total Footage Run = ########
209.803922 114.190476
TOTAL USED
FC
* DISPLACEMENT Pump output, bbl/stk To Land Casing Plug, bbls To Land Casing Plug, stks
FS
TYPE WELLHEAD & TEST PRESSURE ID Previous Casing = Mfg & Type = CIW 16-3/4" 5M x 13-5/8" 5M 'WF' Spool This Casing OD = WH Con't = With 2-2 1/16" 5M Outlet Valves Nominal ID This Casing = Test PSI = 2,815 Hole Size For This Casing =