Professional Documents
Culture Documents
http://www.cranecopper.com.au/sizes/bsen1057.asp
EN 1057 - TYPE Y
Size mm 6 8 10 12 15 18 22 28 35 42 54 66.7 76.1 108 Nom. Dia. (Outside) mm 6 8 10 12 15 18 22 28 35 42 54 66.7 76.1 108
+
Nom. Wall Thickness mm 0.8 0.8 0.8 0.8 1.0 1.0 1.2 1.2 1.5 1.5 2.0 2.0 2.0 2.5
Hard bar
+
Annealed bar
+
144 105 82 67 67 55 53 42 41 34 36 28 25 22
Usage: Underground works and heavy duty requirements including hot and cold water supply, gas reticulation, sanitary plumbing, heating and general engineering.
EN 1057 - TYPE X
Size mm 6 8 10 12 15 18 22 28 35 42 54 66.7 76.1 108 133 159 Nom. Dia. (Outside) mm 6 8 10 12 15 18 22 28 35 42 54 66.7 76.1 108 133 159
+
Nom. Wall Thickness mm 0.6 0.6 0.6 0.6 0.7 0.8 0.9 0.9 1.2 1.2 1.2 1.2 1.5 1.5 1.5 2.0
Hard bar
+
Annealed bar
+
133 97 77 63 58 56 51 40 42 35 27 20 24 17 14 15
5
161 118 93 76 71 67 62 48 51 43 33 27 29 20 17 18
102 75 59 48 45 43 39 31 33 27 21 17 18 13 10 12
Usage: Above groundservices including drinking water supply, hot and cold water systems, sanitation, central heating and other general purpose applications.
EN 1057 - TYPE Z
Size mm 6 8 10 12 15 Nom. Dia. (Outside) mm 6 8 10 12 15 Nom. Wall Thickness mm 0.5 0.5 0.5 0.5 0.5
113 98 78 64 50
1 of 2
04/07/2013 17:04
http://www.cranecopper.com.au/sizes/bsen1057.asp
0.6 0.6 0.6 0.7 0.8 0.9 1.0 1.2 1.2 1.5 1.5
+ 5
Usage: Above groundservices including drinking water supply, hot and cold water systems, sanitation, central heating and other general purpose applications.
# Note: Elongations for half hard tubes depend on the ratio of outside diameter to wall thickness. * MPa: Minimum tensile strength ** Hardness HV/5 indicative
A Nice
site.
2 of 2