ABB industrial drives, ACS800

Plug-in and filter Options

eLearning
Copyright 6/27/2013 ABB. All rights reserved.

Help

Objectives
After completing this module, you will be able to Recognize the plug-in options List the functions of plug-in options List the filter options

Copyright 6/27/2013 ABB. All rights reserved. - 2 -

Help

Plug-in options
Used to provide additional connections between the drive and other devices

Fieldbus Pulse encoder Extended I/O

Software-dependent

Copyright 6/27/2013 ABB. All rights reserved. - 3 -

Help

Option Slot Allocation


Slot 1 (Upper)

Digital I/O extension (RDIO) Analogue I/O extension (RAIO) Pulse encoder interface (RTAC) Fieldbus interface

Slot 2 (Middle)

Digital I/O extension (RDIO) Analogue I/O extension (RAIO) Pulse encoder interface (RTAC)

Slot 3 (Lower)
Copyright 6/27/2013 ABB. All rights reserved. - 4 -

DDCS link (RDCO)

Help

Mounting
Two I/O options can be mounted onto a drive Snap on to the skeleton covering the RMIO-01 or to the AIMA extension board Board grounding to chassis with locking screws Connection via parallel bus connector to the RMIO or to the AIMA extension board Node numbering 015 via switch
Copyright 6/27/2013 ABB. All rights reserved. - 5 -

Indication LEDs in the option module Terminals for the outside connections

Help

RDIO-01 Block Diagram


X10 Address Data RXD/TXD +5V
NODE ADDRESS

+24V

DI1 DI2 DI3 WD/ ON ON ON INIT

IOCC-2B ASIC
0..15

= ~
Copyright 6/27/2013 ABB. All rights reserved. - 6 -

= ~
X12 1 2 DI2

= ~
3 4 DI3 X21 1 2 3 RO1 X22 1 2 3 RO2

X11 1 2 DI1

Help

RAIO-01 Block Diagram


X10 Address Data RXD/TXD +5V
NODE ADDRESS

WD/ INIT

+24V

+24V 0..15

IOCC-2B ASIC
D D A
AI1 /U/I
3x

= =
/U/I
3x

= =
RC

AI2

D A RC
AI1 AI2

Copyright 6/27/2013 ABB. All rights reserved. - 7 -

X1 1 2 AI1

3 4 AI2

5 6 SHLD

X2 1 2 AO1

3 4 AO2

5 6 SHLD

Help

RTAC-01 Block Diagram


X10 Address Data RXD/TXD +5V
NODE ADDRESS

+24V

CHA CHB WD/ ON ON INIT

IOCC-2B ASIC
16..31

= =
RC
Copyright 6/27/2013 ABB. All rights reserved. - 8 -

X2 1 2

3 4

5 6

X1

1 2 3 4 5 6
SHLD -VOUT +VOUT +15V EXT +24V

CH A CH B CH Z

Help

Fieldbus Block Diagram


X10 Address Data RXD/TXD +5V

DPRAM
CONFIG.

FBUS CTRL

MCU
IND.

= =
+5V

RAM
RC

FLASH
Copyright 6/27/2013 ABB. All rights reserved. - 9 -

X1 1 2
FIELDBUS CONNECTOR

Help

RDCO channels
Four fiber optic channels

Channel 3 for PC Tools Channel 2 for NTAC/ Master Follower


Copyright 6/27/2013 ABB. All rights reserved. - 10 -

Channel 1 for NDIO, NAIO, NTAC Channel 0 for Fieldbus adapters

Help

AIMA-01 I/O module adapter


For connecting I/O extension modules

3 slots for RDIO, RAIO and RTAC Connected to I/O channel CH1 of RMIO

Copyright 6/27/2013 ABB. All rights reserved. - 11 -

Copyright 6/27/2013 ABB. All rights reserved. - 12 -

I/O Extension with AIMA

CH1
RDIO RDIO

AIMA

Help

Help

I/O Extension with N-type modules


X2 876 54321 X2 876 54321

R2NC R2CMR2NO

R1NC R1CMR1NO

R2NC R2CMR2NO

R1NC R1CMR1NO

X2

X2

NDIO-02
DI GITAL I /O EXTENSIO N

RXD

NDIO-02
DI GITAL I /O EXTENSIO N

RXD

TXD

TXD

X1
DI1A DI1B DI2 A D I 2B +24V 0V

X1
DI1A DI1B DI2 A D I 2B +24V 0V

123 45678
Copyright 6/27/2013 ABB. All rights reserved. - 13 -

123 45678 X1

X1

Help

Filters
ACS800-02/ACS800-07 ACS800-01
Cabinet

EM C
Line filter

ACS800

Internal RFIBoards

Internal RFIBoards

EMC du/dt

ACS800-02/ACS800-07

Common mode Sine


du/dt filters are not needed if a sine filter is used

Copyright 6/27/2013 ABB. All rights reserved. - 14 -

ACS800