Professional Documents
Culture Documents
PC\4
4-LINE CALLER IDENTIFICATION INTERFACE
TECHNICAL INFORMATION
APPROVED:
JR.._
ISSUE4 October 23, 1996
DIRECTOR OF ENGINEERING
REV.l
12/19/94 ISSUE 1
REV. I
12/19/94 ISSUE 1
REV.l
12/19/94 ISSUE 1
REV.l
12/19/94
PC\4
lssue4; IM3/96
Copyright
No part of this publication in whole or in part may be reproduced, translated into another language, stored in any retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior written consent of BEK-TEL, Inc .. Every precaution has been taken in the preparation of this publication. BEK-TEL, Inc. assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein.
An FCC compliant telephone cord and modular plug is provided with this equipment. This equipment is designed to be connected to the telephone network or premises wiring using a compatible modular jack which is Part 68 compliant. See installation instructions f"or details.
PC\4
Issue 4; 1<Y23/96
NOTICE
The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Industry Canada does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, user's should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company's inside wiring associated with a single line individual service may be extended by means of a certified connector assembly. (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. User's should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.
The~ (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the re,quirement that the total of the Load Numbers of all the devices does not exceed 100.
Table Of Contents
1.0 GENERAL D:ESCRIP'fiON e
e e e eo e e e e e e e e e e e e e e e e e e o o e e Gee" e e e e e e e
PAGE 1 PAGE 1
I..
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PAGE4
. . . . . . . . . . . . . . . . . . . . . . . . PAGE 11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PAGE 12
~~
4.0 SPECIFICATIONS o
PAGE 13
4.1 ENVIRONMENTAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PAGE 13 4.2 MECHANICAL . . . . . . . . . . . . . . . . . . . . . . . . . . , . . . . . . . . . . . . . . . PAGE 13 5.0 LIMITED WARRANTY PAGE 14
FCC REQUIREMENTS PAGE 16
RADIO J:N'TERFERENCE e
Q..........
PAGE 17
PC\4
Issue 4; 1<Y23/96
1.0
1.01
GENERAL DESCRIPTION
1.07
The PC\4 receives the Caller ID (Identification) data from the Telephone Company and sends the data, in ASCll RS-232C format to a printer, terminal, computer or DTE (Data Terminal Equipment) device. As an interface, the Pa4 only receives, converts and then resends the the Caller ID information to a DTE device. All or any printing or displaying of the data is done by the (customer furnished) D1E device. The PC\4 is compatible with most key systems and PBX' s, and is also compatible with most of the current C.O. based message waiting services. This device is single and multiple message compatible.
On the Back Panel there are two connectors, RS-232 IN and RS-232 OUT, these connectors enable up to eight (S) P04' s to be connected together and provide up to 32lines or PORTS with a single RS-232 output.
1.02
Pa4's and PaS's can be used together to obtain thirty-two possible lines. Be sure the PC\4's are connected after the PaS's in sequence when multipled together. Whenever a Pa4 is connected, the maximum number of lines available will be thirty-two (32). If there are more than thirty-two lines, then you cannot mix the PaS's and Pa4's. If a 4-Line Caller ID Interface and an S-Line Caller ID Interface are used, then each S-Line Caller ID Interface will count as two Units. For example, if an 8-Line and a 4-Line Caller ID Interface are connected in sequence (to obtain 12 lines), then the S-Line Caller ID Interface must be set for Unit #1 and the 4-Line Caller ID Interface must be set for Unit #3. Each S-Line Caller ID Interface counts as two 4-Line Units when they are connected together.
1.08
1.09
1.03
Caller ID services are currently being offered by many telephone companies as a subscribed service (check for service availability).
There is also a Dip Switch (S1) which is located on the faceplate. This Dip Switch contains eight swi1tches each which control the Baud Rate, Data Bits, Parity, voltage and line or port specifications Jfor configuring the Pa4 to the DTEdevice. Ports 1 through 4 are located on the Back Panel. These are RJ-14C input jacks are connected (via modular telephone connections) directly to the incoming central office telephone lines. These PORT inputs will be parallel connections with the telephone device associated with that line. The Power Supply connector is also located on the Back Panel. This is an external A. C. power adapter requiring a common AC outlet.
1.04
2.0
2.01
DETAILED DESCRIPTION:
1.05
The Pa4 receives the Caller ID data from the local telephone company and converts this information into ASCIT, RS-232C format. After converting the data, the information is then transmitted out the RS-232 OUT connection
(J2).
1.06
Calls are received via any of the four line in, PORTS 1-4. The modular connections are connected directly to the incoming central office telephone lines in parallel with the telephone, Key System or PBX (see Figure 1, Page 2).
2.02
TO C.O.
TO
~ ..--~
N E
(j~
c;
~~
#
TO 12V POWER
~#
UNES 1 2 3 4
ADAPTER
c
0
a:
" jV V
::l 0
DTE
(PRINTER,TERMINAL,
COMPUTER,ECT) DEVICE
IN
I OUT
R5-232R5-232
PC\4
FIGURE 1
PC\4 CONFIGURATION
p 0
PC\4
LINES I""
TO
CJtOSS.CONNECr
ANJ),I()Jl
UNIT
R T
It
r-LINES 5-11
p 0
PC\4
UNIT In
R T
RS-1321N
I-LINES ,_12
IIS-132 OUT t - -
PC\4
UNIT 13
p 0 R T
LINES 13-16
PC\4
UNIT M
p 0 R T
r-LINES 17Z8
p 0
PC\4
UNIT
R T
115
LINES 21-24
UNIT
R T
"'
PC\4
RS-132 IN
RS-132 OUT
r-LINES 25-21
UNIT lf7
p 0 R T
LINES U-32
p 0
PC\4 UNIT Ill
R
T
RS-132 IN
1--
RS-132 OUT
J
DTE DEVICE
(PRIN1'U.TEllMINAL, COMl'UTER,ECI'-)
FIGURE2
MULTIPLE PC\4's
PC\4
Issue 4; 10123/96
Upon receiving the data, the P04 stamps the incoming Caller ID information with the port number and then converts it to ASCII, RS-232. After converting the data the information is sentto the RS-232 OUT connection. ThePC\4 will indicate that data has been received only if a DTE device is connected to the RS-232 OUT port. The "DATA" L.E.D. will indicate the unit is sending data to the RS-232 OUT port. After the data has been transmitted to the DTE device, it will be up to the user to apply the data in any fashion required. This may include purchasing or writing a software program to use this data with a database or computer. However, it is not required to have a program to use the ro4; the ASCII, RS-232 data format is accepted by most printers and/ or terminals. Therefore, the ro4 can be connected directly to a DTE device, and the data will be readable.
2.03
together to provide up to thirty-two (32) lines or ports, with one (1) RS-232C output.
2.04
2.1 CONNECTIONS
NOTE
The RS-232 OUT connector pin 7 (CTS input) must be pulled active (High) for the PCvl to tum on its "DATA" LE.D. when receiving Caller ID information from the telephone line.
RXD
Receive Data SG
Input
5
7
crs
Clear To Send RTS
Output
TABLE 1
PC\4
Issue 4; 1<Y23/96
PIN#
PIN#
8
T
2
3
2
RS-232 OUT
MALE
9 Pin, "D"-sub
3 4 - Not Connected 5 6
7 8 9
'--
7
6
DTE MALE/FEMALE
25 Pin, "D"-sub
20 5 22
NOTE
This cable configuration is correct for most applications requiring a 9-pin to 25-pin RS-232 conversion. It is recommended that the DTE device owner's manual also be consulted
FIGURE3
RS-232 OUT to DTE Device Cable
PIN#
PIN#
T
RS-232 OUT
MALE
2 3 4 5 6 7 8 9
-
Pins3~4
connected.
2 3
9 Pin, "D"-sub
5 6 7 8 9
'---
NOTE
This cable configuration is correct for applications using more than one PC\4.
FIGURE4
RS-232 IN to RS-232 OUT Cable
PC\4
Issue 4; 1003/96
a terminal or P.C .. However, always consult the manual for the DTE device before constructing a cable.
SIGNAL NAME CD
TXD Transmit Data SG Ground DTR
CTS Clear To Send RTS
INPUT/
6
7
Output Input
TABLE2
be contructed according to the compatibility requirements of the DTE device (i.e., input connector and signal pins).
2.2.2 DATA BITS: 2.2.2.01 The number of Data Bits being sent is
specified by the ON or OFF position of Switch 3.
2.3.2 L.E.D.'s and CONNECTORS2.3.2.01 The PC\4 is equipped with two green
L.E.D. 's (Light Emitting Diodes) located on the front panel labeled PWR and DATA. When power is applied to the PC\4, the green power (PWR) L.E.D. will illuminate. The DATA L.E.D. will flash ON as data is sent from the PC\4 to the DTE device. The DTE device must be connected and online before the PC\4 "DATA" L.E.D. will illuminate to indicate data is being sent
2.3.2.02 The RS-232 OUT connector (located 2.2.3.02 When there are 2 or more units (8
maximum) connected together, the incoming call path will be specified by the ON/OFF position of Switches 6 through 8. on the Back Panel) uses a standard cable with a 9-pin, "D"-sub connector connected as a DCE device. This connection goes to the DTE device (if only one PC\4 is used) or the next PC\4' s RS-232 IN connector (if more than one unit is "multipled"). Also, if the PC\4 is the last unit in the sequence, then the RS-232 OUT connection will go the DTE device. Refer to Figure 2, Page 3.
NOTE
THE RS-232C "D"-SUB CONNECTORS AND CABLING WILL BE SUPPLIED BY THE CUSTOMER.
2.3.3 DATA SENT2.3.3.01 Data is sent between the first and second
ring cycles. The data received (202A modem tones) will be converted into the standard
Pa4
Issue 4; 1<V23/96
ASCII, RS-232 format. After the data is formated, it is sent to the RS-232 OUT port. NOTE IF HANDSHAKING IS PROLONGED, DATA WAITING TO BE RECEIVED WILL BE LOST.
Data (DATA) GREEN L.E.D.- This L.E.D. illuminates when data is being sent from the P04 to the DTE device.
2.3.6 CONNECTORS:
POWER - This is an external power supply adapter connection. PORTS 1-4- These are RJ14 phone jacks which connect directly with the central office telephone lines. RS-232 IN - Connect the RS-232 OUT connector of the first unit, to the RS-232 IN connector of the second or next unit using a standard (1:1) 9 pin "D"-sub connector. RS-232 OUT - This connector is used to connect the P04 to the DTE device. If more than one unit is installed, cable from the RS-232 OUT connector of the previous unit to the RS-232 IN connector of the next unit in the chain (using a 1:1 cable). Connect the RS-232 OUT connector, of the last unit, directly to the DTE device (this will be the cable constructed to connect specifically between the PC\4 and the DTE device). Refer to Figure 8.
2.3.5
L.E.D.'s :
Power (PWR) GREEN L.E.D.- This L.E.D. illuminates when power is applied to the PC\4. Data L.E.D. Power L.E.D.
FACEPLATE
FIGURES
3/24 3/24 9:16AM. 3/24 10:03 AM. 3/25 10:03 AM. 3/25 10:06 AM.
NAME
FIGURE6
SAMPLE DATA OUTPUT
Pa4
Issue 4; 1003/96
TELEPHONE UNES
c.o.
FIGURE7
MULTIPLE OF EIGHT PC\4's
PC\4
Issue 4; 11Y23/96
2.3.7 MESSAGE FORMAT AND DATA OUTPUT 2.3.7.01 The PC\4 receives the standard Caller ID
fonnat from the central office , formats the data, and sends it to the RS-232 OUT port. This data is sent (by the telephone company) between the first and second ring cycles to the
Port # -This tells the operator what line is being seized for a specific call. Sent by the PC\4. Date- Records date call was made. Sent by the local Telco. Time- Records time (Hour: Minutes: AM/PM) call was received. Sent by the local Telco. Phone Number - Displays phone number of calling party (maximum of 11 digits displayed). Sent by the local Telco. Long Distance Indicator - If the call originated from another area code , an "L" may appear in this column, indicating a Long Distance call. Sent by the local Telco. N arne -The name of the calling party will appear in this column (up to 15 characters) and is case sensitive. This field is used only where Multiple Message fonnat and "Call Name Delivery" service is available and the name is sent by the local Telco.
BACK PANEL
RS-232C OUT
D-sub connector
Power Supply
Adapter
D-sub
~-232 IN
FIGURES
POBT 08 01 03 02 05
DATE TDVIB PHONE NUMBEll 3/24 9:15AM OUT OF AREA 3/24 9:16AM 1-205-881-4000 3/24 10:03 AM 881-4000 3/25 10:03 AM PRIVATE 555-1234 3/25 10:06 AM
FIGURE9
SAMPLE DATA OUTPUT
10
3.0
0 0
INSTALLATION
2 each, 4 conductor Modular cord (user supplied). See Figure 10, page 12. required (e.g.. if eight units are being used, 8 AC Power outlets are required). There must be plenty of distance between the outlets for the power adapters.
3.3.04 See Figure 7, Page 9. 3.3.05 Plug the AC Power Supply into a
convenience outlet. The Power (PWR) L.E.D. for each unit should illuminate.
0 Secure using appropriate hardware. 0 Plug telephone Lines 1 and 2 into PORT 1,
Lines 3 and 4 into PORT 2.
11
PC\4
Issue 4; l!Y23/96
II
RJ-14C Connections 1- Open 2- Port 2 or 4 (Tip) 3- Port 1 or 3 (Tip) 4 - Port 1 or 3 (Ring) 5 - Port 2 or 4 (Ring) 6- Open
Monitoring the DTE device, the data (as shown in Figure 9, Page 10) will be displayed and/or printed. Hang-up the test line and then repeat the process for the next line to be tested. Do this for all lines connected.
I I I I I I
REAR VIEW RJ-11 P CONNECTOR 6 POSITION
FIGURE 10
WARNING
Your computer must be properly Grounded. Failure to properly ground your computer may result in the intermittent operation of the unit. DO NOT USE A.C. ISOLATION PLUGS.
0 Check the AC convenience outlet for power. 0 Try to place a call. If call/data is delayed, lost
or if unit does not respond [Power (PWR) L.E.D. illuminates] the unit and/or L.E.D. is defective and the unit should be returned for repair.
If the data is not printed and/or displayed at the
DTE device (printer, terminal, CPU), check the Power (PWR) and data (DATA) L.E.D.'s for illumination and flashing. If illumination is not occurring, see section on Power (PWR) and data (DATA) L.E.D.'s.
Check C.O. Line to PORT positions connections. DTEdevice. Ensure proper Dip Switch selections are made for baud rate, data bits and Parity. Do these selections conform to the DTE device specifications? If multiple units are installed, check each RS-232 OUT cable to each RS-232 IN connection. outs according to Table 1, Page 4.
3.5 TESTING
0 0 Go Off-Hook from an outside test line and dial the telephone number of the line to be tested. Between the first and second ring cycles, the DATA L.E.D. will flash as the Caller ID information is being sent to the DTE device.
12
PC\4
Issue 4; 1CV23/96
If information at DTE device is "GARBLED", check the baud rate switch selections for the PC\4.
4.0
SPECIFICATIONS:
0
0
Check the parity and data bit selections for the DTE device and ensure that they are selected in accordance with that of the PC\4. When 1 of the 4lines is not functioning, check the data (DATA) L.E.D. to see if it flashes when data is sent.
Power Supply Voltage: . . . . . . . . 120V AC Power Supply Current: . . . . +12V@ 100 rnA Receive Level: . . . . . . . . . . -10 to -33 DB Temperature Range: . . . . . . . 10 to 120 F Baud Rates: . . . . . . . 1200,2400,4800,9600 Data Links: . . . . 7 or 8 data bits per character Parity: . . . . . . . . . . . . Odd, Even or None. Start Bit: . . . . . . . . . . . . . . . . . . . . 1 Stop Bit: . . . . . . . . . . . . . . . . . . . . 1
4.1 ENVIRONMENTAL:
Storage Temperature Range: . . . . . . . . . . . . . . . 0to 150 F Operating Temperature Range: . . . . . . . . . . . . . . +10- 120 F Humidity Range: . . . . . . . . . . 20% to 90% Non Condensing
Check the cable connection from the previous PC\4 (RS-232 OUT) to the next PC\4 (RS~232 IN) connector in sequence.
4.2 MECHANICAL:
Height: . . . . . . . . . . . . . . . 1.875 inches Width: . . . . . . . . . . . . . . 8.3125 inches Length: . . . . . . . . . . . . . . . . 9.0 inches Weight: . . . . . . . . . . . . . . . . . 2.0 lbs. Shipping Weight (incl. Power Adapter) . . . . . . . . . 3.0 lbs.
13
PC\4
Issue 4; 1<Y23/96
5.0
LIMITED WARRANTY
Bek-Tel warrants to the original purchaser of this product that the product will be free from defects in material or workmanship for a period of 24 months from the date of purchase under normal use and service. Bek-Tel makes no other warranty with respect to this product, either express or implied. BEK-TEL SPECIFICALLY DISCLAIMS ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. This warranty does not cover product damage or failures arising from product shipment, accidents, misuse, neglect, mishandling, unauthorized service, alteration or modification, or from failures of electrical power or environmental control systems. As the sole and exclusive remedy available for original purchasers of products having defects in material or workmanship during the warranty period, Bek-Tel will, at its sole option, either replace the defe:ctive product or repair the defective product with new or rebuilt parts, free of charge, when suc:h product is returned with a Return Material Authorization number, postage prepaid, to the Bek-Tel repair facility in Portland, Oregon. IN NO EVENT WILL BEK-TEL BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE PURCHASE, USE, OR INABILITY TO USE THE PRODUCT OR THE PRODUCT DOCUMENTATION, EVEN IF BEK-TEL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, BEK-TEL SHALL NOT BE LIABLE FOR THE LOSS OF INFORMATION ARISING FROM THE USE OF THE PRODUCT. BEK-TEL'S MAXIMUM LIABILITY FOR ANY CLAIM ARISING FROM THE PURCHASE OR USE OF THE PRODUCT, INCLUDING, WITHOUT LIMITATION, CLAIMS BASED UPON BEK-TEL'S NEGLIGENCE, SHALL BE LIMITED TO THE
RETURN OF THE PRICE ACTUALLY PAID TO BEK-TEL BY THE ORIGINAL PURCHASER FOR THE PRODUCT UPON ACCEPTABLE PROOF OF PURCHASE. The warranties and remedies set forth above are exclusive and in lieu of all others, oral or written, expressed or implied. No Bek-Tel distributor, employee or agent is authorized to modify or extend the above warranties or remedies in any manner. SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR THE LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. If a problem with this product arises during or after the warranty period, the original purchaser may contact the Bek-Tel repair facility at (503) 639-5354 for a Return Material Authorization number. Out-of-warranty repairs will be made for a fee based upon Bek-Tel's service rate at the time of the product's return.
When returning a defective unit, include the following:
BEK-TEL
10110 SW Nimbus Suite #B-11 Portland, OR 97223
14
(5)
(5)
(5)
(5)
(14)
(5)
(1)
(5)
(15)
(1)
(1)
TIME
SPACE I~D SPACE SPACE PHONE NUMBER FILLED IND FILLED FILLED
NAME
(Name can be case sensitive)
CR
LF
MESSAGE WAITING
ODH OAH
02
MESSAGE RETRIEVED
ODH OAH
03
INVALID DATA
ODH OAH
Vl
10
1/07
12:56 PM
1-205-881-4000
ODH OAH
12
2114
4:00PM
205-881-4000
ODH OAH
19
4/01
10:45AM
881-4000
22
10/10
3:57PM
PRIVATE
ODH OAH
29
11/25
2:30PM
OUT OF AREA
ODH OAH
32
12115
7:35AM
1-205-881-4000
l
..
~~----
ODH OAH
---- --------
r
~Q
FCC REQUIREMENTS
This equipment complies with Part 68 of the FCC Rules. On the underside of this equipment is a label that contains, among other information, the FCC registration number and Ringer Equivalence Number (REN) for this equipment. H requested, provide this information to your telephone company. 1. The Federal Communications Commission (FCC) has established Rules which permit this device to be directly connected to the telephone network. Standardized jacks are used for these connections. This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs. (Contact your state public utility commission or corporation commission for information.) 2. H this device is malfunctioning, it may also be causing hann to the telephone network; this device should be disconnected until the source of the problem can be determined and until repairs have been made. H this is not done, the telephone company may temporarily disconnect service. H possible, they will notify you in advance. But if advance notice isn't practical, you will be notified as soon as possible. You will be advised of your right to file a complaint with the FCC. 3. The telephone company may make changes in its technical operation and procedures; if such changes affect the compatibility or use of this device, the telephone company is required to give adequate notice of the changes. 4. If the telephone company requests information on what equipment is connected to their lines, inform them of the following:
Port ID PC/4 REN/SOC O.OB/9.0F FIC 02LS2, 02GS2 USOC RJ14C
The ringer equivalence (REN) is used to determine how many devices can be connected to your telephone line. In most areas, the sum of the REN' s of all devices on any one line should not exceed five (5.0). If too many devices are attached, they may not ring properly. SERVICE REQUIREMENTS 5. In the event of equipment malfunction, all repairs should be performed by our Company or an authorized agent. It is the responsibility of users requiring service to report the need for service to our Company or to one of our authorized agents. Service can be obtained at:
16