Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Digital (IFM/XIM and Cables) Options and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Cat. No. Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Analog (AIFM and Cables) Options and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Cat. No. Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Ordering Digital and Analog Wiring Systems. . . . . . . . . . . . . . . . . . . . . . . . . . 23 Selection Tables Bulletin 1746 SLC 500 IFMs, XIMs, AIFMs, and Cables . . . . . . . . . . . . . . . . . . 25 Bulletin 1756 ControlLogix IFMs, XIMs, AIFMs, and Cables . . . . . . . . . . . . . . . 30 Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500 IFMs, XIMs, AIFMs, and Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Bulletin 1771 PLC-5 IFMs, XIMs, AIFMs, and Cables. . . . . . . . . . . . . . . . . . . . 40 IFM-Ready I/O Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Build-to-Order Length Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Specifications Digital IFMs and XIMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Digital Cables and Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 Analog IFMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131 Analog Cables and Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Dimensions Digital IFM Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 Digital XIM Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 Analog IFM Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 Marking Systems Digital Adhesive Label Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163 Analog Adhesive Label Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 Web Site Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
Description
Connecting to Allen-Bradley I/O is convenient with Allen-Bradley Interface Modules and Cables. Unlike conventional terminal blocks, they connect through pre-wired cables to digital and analog I/O for the Bulletin 1746 SLC, Bulletin 1756 ControlLogix, Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500, and Bulletin 1771/PLC-5 platforms. The interface modules are mounted onto a standard DIN #3 Rail. Pre-printed adhesive label cards containing field-wiring information are available for each interface module and I/O module combination. Wiring systems are available for over 90 digital I/O modules and over 40 analog I/O modules.
D igital/Analog Programm ab le Co ntroller W irin g Systems
Benefits
Benefits, Continued
Simplified Design
Design engineers can simplify their panel drawings by calling out an IFM and pre-wired cable instead of having to detail every single wire and terminal block on their drawings. Simplified panel drawings aid not only the installer, but also the end customer who receives the panel.
Benefits, Continued
Quality-Looking Panels
The pre-wired cables and IFMs organize the wiring in your panel and provide a consistent look. Pre-printed adhesive labels for the terminals neatly identify field-wiring connections, which correspond to the I/O module address. A large marking area is also available for identifying I/O information on the IFM.
Design Flexibility
To develop a cost-effective system, the hardware components must meet the needs of the design engineer. Rockwell Automation provides the broadest range of digital and analog systems in the industry. Allen-Bradley Wiring Systems deliver a lower life-cycle cost.
Digital IFMs, similar to groups of terminal blocks, are available with either 20-pin or 40-pin cable connectors. The number of field-side wiring terminals varies with the type of module from one to three terminals per I/O point. LEDs and fuse clips are available on-board the IFMs to customize your wiring system to your application and provide assistance with troubleshooting your control panel. The IFMs are compatible with both the pre-wired cables and the IFM-ready cables. All of the digital IFMs have the following features:
Large rectangular write-on area acts as built-in group marking carrier for programmable controller rack, module group, and/or slot information.
UL Component Recognized (File E113724 Guide NRAQ2); UL recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2); CE Approved; Factory Mutual Listed (File J.I. 3000590) FM approved.
Pre-printed and blank adhesive marking strips are provided to identify either Programmable Controller I/O field-side wiring terminals or your own application requirements.
Keyed cable connector (20- or 40-pin) with locking tabs for easy installation and secure connection of IFMs.
High-density field-side wiring terminals allow more connections in less space and accommodate #2212 AWG wire.
Continuous current rating of 2 A per circuit supports higher-current programmable controller output modules.
Standard terminal IFM modules provide one field-side wiring terminal per programmable controller input or output point, as well as enough terminals for the I/O module power connections. The standard terminal modules are ideal for applications in which the I/O device commons are terminated in the field or remotely from the I/O module panel.
Extra terminal modules provide two or four field-side terminals per input or output point. Non-isolated IFMs have two terminals per input or output. Isolated IFMs have two or four terminals per input or output. Non-isolated IFMs have the lower row of extra terminals commoned together in groups of 10 , to serve as a power bus for the field device commons. Isolated IFMs have terminals isolated into 8 or 16 groups, which allows each group of I/O devices to reference a different power source. The extra terminal modules are beneficial in applications in which the I/O devices are terminated within the same panel as the I/O modules eliminating the need for many additional terminal blocks. These modules are also available with optional field-side status LEDs for troubleshooting inputs and outputs.
Except Cat. Nos. 1492-IFM20D24A-2 and -IFM20D120A-2, which are in groups of 20.
Sensor Modules
Sensor modules provide three field-side terminals per input point. The middle and lower rows of terminals, commoned together in groups of 18, serve as power busses for 3-wire sensor types of devices eliminating additional terminal blocks and jumpering systems. Optional field-side LEDs identify the on/off condition of the sensor signal. The sensor modules provide a compact method of terminating and powering 24V AC/DC or 120V AC (Cat. No. IFM20F-3 only) 3-wire devices.
LED Modules
Voltage-indicating LEDs are available on the standard, extra terminal, and sensor IFMs. The LEDs provide field-side troubleshooting diagnostics: the on/off status of an input device or the on/off status of the programmable controller output circuit. When used in conjunction with the logic-side programmable controller LEDs, the IFM LEDs can help determine whether a problem resides in the I/O module or field device/wiring. The LED modules have unique circuitry that allows compatibility with sinking or sourcing input or output modules.
Fusible Modules
Fusible modules provide a convenient method of adding overcurrent protection into your programmable controller wiring. These modules have 5 x 20 mm fuse clips on-board and are available with and without blown fuse indication. The 24V or 120V blown fuse indicators reduce the troubleshooting time to locate and replace a blown fuse on the IFM. The fusible modules have an easy-to-remove see-through acrylic cover to prevent objects from contacting fuse circuitry under normal operation. Standard fuse holders reside in the IFM, aiding in the removal of a fuse with a fuse puller (fuses are not included). The fusible modules also have two or four terminals per I/O point to create a power bus for input or output load connections. Fusible modules are available in both isolated and non-isolated versions. There are a select number of fusible IFMs available for input modules.
Relay master XIMs feature field-replaceable relays with 120V or 24V rated coils. The field-side Form C contacts are rated 240V 10 A (de-rated to 12 A per adjacent pair on the XIM). The Form C relay output provides isolated output channels and a different voltage level from one output channel to the next. Other features include coil-side LED indicating the output module status, and transient suppression on each coil. The 24V relay master for 32-point outputs is offered with either 8 or 16 relays on one module.
Relay Expanders
Relay expander XIMs feature eight field-replaceable relays with 120V or 24V rated coils. The field-side Form C contacts are rated 240V 10 A (de-rated to 12 A per adjacent pair on the XIM). The Form C relay output provides isolated output channels and a different voltage level from one output channel to the next. Other features include coil-side LED indicating the output module status, and transient suppression on each coil. An expander cable is provided for connection to the mating module.
10
The fusible expander modules feature eight 5 x 20 mm finger-safe fuse holders, blown fuse indicators, and extra terminals for landing two wires per field-side device. They are offered with eight fuse holders for both 24V and 120V applications. An expander cable is provided for connection to the mating module. Fuses are not provided.
Feed-Through Expanders
The feed-through expander modules feature eight channels with extra terminals for landing two wires per field-side device. An expander cable is provided for connection to the mating module.
11
Bulletin 1492 pre-wired cables are designed to minimize control wiring in a panel. Pre-wired cables, when used with an IFM, replace the point-to-point wiring between Allen-Bradley programmable controller I/O modules and individual terminal blocks. The pre-wired cables have a removable terminal block or wiring arm at the I/O end of the cable and a cable connector on the other end to connect to the IFM. All of the pre-wired cables use #22 AWG wire and are 100% tested for continuity to make a perfect connection every time. The digital pre-wired cables are offered in four standard lengths of 0.5, 1.0, 2.5, and 5.0 m to fit a variety of applications. Other cable lengths are also available as build-to-order products. Pre-wired cables are available for many of the 1746 SLC I/O, 1756 ControlLogix I/O, 1769 Compact I/O for CompactLogix and MicroLogix 1500, and 1771 PLC-5 I/O controllers.
I/O-ready cables have an I/O removable terminal block or wiring arm prewired to one end to of the cable and free connectors on the other end for wiring into standard terminal blocks or other type of connectors. I/O-ready cables have individual color-coded conductors for quick wire-to-terminal coordination. The I/O-ready cables use #18 AWG conductors for higher current applications or longer cable runs. The I/O-ready cables are offered in standard lengths of 1.0, 2.5, and 5.0 m to fit a variety of applications. Other cable lengths are also available as build-to-order products. Pre-wired cables are available for the Bulletin 1746 SLC I/O, Bulletin 1756 ControlLogix I/O, Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500, and Bulletin 1771 PLC-5 I/O controllers.
Publication 1492-TD008A-EN-P - March 2001
12
IFM-ready cables have a cable connector that attaches to the IFM pre-wired to one end and free connectors ready to wire to I/O modules or other components on the other end. IFM-ready cables use #22 AWG wire and have individual color-coded conductors for quick wire-to-terminal coordination. The digital IFM-ready cables are offered in standard lengths of 1.0, 2.5, and 5.0 m to fit a variety of applications. Other cable lengths are also available as build-to-order products.
13
Important: The following IFM cat. no. breakdown is for explanation purposes only. It is not a product configurator. Not all combinations of fields are valid product cat. nos. First, select the desired IFM using the steps in Ordering Digital and Analog Wiring Systems on page 23. Then, use this breakdown for verification and explanation only.
1492IFM 20 FF1202
Bulletin No. No. of Field-Side Wiring Terminals Blank One per I/O connection 2 Two per I/O connection 3 Three per I/O connection 4 Four per I/O connection
Status Indication F No LEDs FN Narrow IFM D24 24V LEDs for input and output modules D24N Narrow IFM with 24V LEDs D24A 24V LEDs for input modules DS24 Isolated IFM with 24/48V LEDs for output modules DS24A Isolated IFM with 24V LEDs for input modules D120 120V LEDs for input and output modules D120N Narrow IFM with 120V LEDs D120A 120V LEDs for input modules DS120 Isolated IFM with 120V LEDs for output modules DS120A Isolated IFM with 120V LEDs for input modules D240 240V LEDs for output modules DS240A Isolated IFM with 240V LEDs for input modules D240A 240V LEDs for input modules
Fuses and Their Indicators Blank No fuse clips F 5 x 20 mm fuse clips F24 5 x 20 mm fuse clips with 24V blown fuse indicators for output modules F24A 5 x 20 mm fuse clips with 24V blown fuse indicators for input modules F120 5 x 20 mm fuse clips with 120V blown fuse indicators for output modules F120A 5 x 20 mm fuse clips with 120V blown fuse indicators for input modules F240 5 x 20 mm fuse clips with 240V blown fuse indicators for output modules FS Isolated IFM with 5 x 20 mm fuse clips FS24 Isolated IFM with 5 x 20 mm fuse clips with 24V blown fuse indicators for output modules FS24A Isolated IFM with 5 x 20 mm fuse clips with 24V blown fuse indicators for input modules FS120 Isolated IFM with 5 x 20 mm fuse clips with 120V blown fuse indicators for output modules FS120A Isolated IFM with 5 x 20 mm fuse clips with 120V blown fuse indication for input modules FS240 Isolated IFM with 5 x 20 mm fuse clips with 240V blown fuse indication for output modules
14
Relay master and expander XIMs are available for Bulletin 1746, 1756, 1769, and 1771 digital output modules. Relay Master XIM Provides 8 or 16 relay outputs for a digital output module. Expander XIM In addition to the relay master XIM, an expander XIM provides eight additional outputs. There are three types of expander XIMs: eight-channel relays, eight-channel fusing, and eight-channel feed-through XIMs.
Relay Master/Expander XIMs Cat. No. Explanation for Digital I/O Modules
Important: The following XIM cat. no. breakdown is for explanation purposes only. It is not a product configurator. Not all combinations of fields are valid product cat. nos. First, select the desired XIM using the steps in Ordering Digital and Analog Wiring Systems on page 23. Then, use this breakdown for verification and explanation only.
1492XIM 20 242
Bulletin No. No. Relays or Extra Terminals 2 2 terminals per point 8R 8 relays 16R 16 relays
No. Cable Connector Pins 20 20 pins (master only) 40 40 pins (master only) Blank Expander module
Rating of Relay Coil or Blown Fuse Indicator 24 24V relay coil 120 120V relay coil F No relays or fuses F-F24 5 x 20 mm fuse clips with 24V blown fuse indicators F-F120 5 x 20 mm fuse clips with 120V blown fuse indicators
15
IFM and XIM Cable Cat. No. Explanation for Digital I/O Modules
Important: Use the following tables as a product configurator for pre-wired, IFM-ready, and I/O module-ready cables for Bulletins 1746, 1756, and 1771 digital I/O module cables. All combinations of these fields make valid product cat. nos. Refer to selection tables for IFM/XIM compatibility and ordering.
1492CABLE 010 A
Bulletin No. Cable Type A, B, C, D, E, G, N, S CR F, T FF
Standard or Build-to-Order Length Cable 005 0.5 m (1.64 ft) Standard 010 1.0 m (3.28 ft) 025 2.5 m (8.20 ft) 050 5.0 m (16.40 ft) 001 0.12.0 m (0.3286.56 ft) Build-to-Order 020 0.1 m (0.328 ft) increments 020 2.010.0 m (6.5632.8 ft) 100 0.5 m (1.64 ft) increments 100 10.099.0 m (32.8374.72 ft) 990 1.0 m (3.28 ft) increments
Pre-wired cables for 8-channel isolated and 16-channel digital Bulletin 1746 I/O modules Pre-wired cable for Cat. No. 1746-OA16 (XIM only) Pre-wired cable for digital Bulletin 1771 I/O modules Pre-wired cable with fused wiring arm for 16-channel digital Bulletin 1771 output modules H Pre-wired cable for 32-channel digital Bulletin 1746 I/O modules J, K, L, M, R Pre-wired cables for 16-channel isolated and 32-channel digital Bulletin 1771 I/O modules U, V, W, X Pre-wired cables for 8- and 16-channel digital Bulletin 1756 I/O modules Y, Z Pre-wired cables for 16-channel isolated and 32-channel digital Bulletin 1756 I/O modules P Digital IFM-ready cable with 20 conductors Q Digital IFM-ready cable with 40 conductors N3 Digital I/O module-ready cable with 40-channel Cat. No. 1746-N3 cable connector RTBB Digital I/O module-ready cable with 16-channel Cat. No. 1746-RT25B terminal block (blue) RTBO Digital I/O module-ready cable with 16-channel Cat. No. 1746-RT25C terminal block (orange) RTBR Digital I/O module-ready cable with 16-channel Cat. No. 1746-RT25R terminal block (red) TBCH Digital I/O module-ready cable with 36-channel Cat. No. 1756-TBCH removable terminal block TBNH Digital I/O module-ready cable with 20-channel Cat. No. 1756-TBNH removable terminal block WA Digital I/O module-ready cable with Cat. No. 1771-WA 8-channelwiring arm WD Digital I/O module-ready cable with Cat. No. 1771-WD 6-channel wiring arm WH Digital I/O module-ready cable with Cat. No. 1771-WH 16-channel wiring arm WHF Digital I/O module-ready cable with Cat. No. 1771-WHF 16-channel fused wiring arm WN Digital I/O module-ready cable with Cat. No. 1771-WN 32-channel wiring arm
To make sure the Bulletin 1746 SLC 500 digital I/O module is compatible with the IFM/XIM, refer to pages 25, 26, and 27. To make sure the Bulletin 1771 PLC digital I/O module is compatible with the IFM/XIM, refer to pages 40, 41, and 42. To make sure the Bulletin 1756 ControlLogix digital I/O module is compatible with the IFM/XIM, refer to pages 30, 31, and 32.
The cables used for Relay Master/Expander XIMs are the same as those used for Digital I/O Modules (page 23) with the exception of the Cat. No. 1746-OA16 output module, which uses the 1492-CABLE*CR cable.
16
IFM and XIM Cable Cat. No. Explanation for Digital I/O Modules, Continued
Important: Use the following tables as a product configurator for pre-wired, IFM-ready, and I/O module-ready cables for Bulletins 1769 and 1771 digital I/O module cables. All combinations of these fields make valid product cat. no. Refer to selection tables for IFM/XIM compatibility and ordering.
Digital Interface Cable Standard or Build-to-Order Length Cable 005 0.5 m (1.64 ft) Standard 010 1.0 m (3.28 ft) 025 2.5 m (8.20 ft) 050 5.0 m (16.40 ft) 001-020 0.12.0 m (0.3286.56 ft) Build-to-Order 0.1 m (0.328 ft increments) 020-100 2.010.0 m (6.5632.8 ft) 0.5 m (1.64 ft) increments 100-990 10.099.0 m (32.8374.72 ft) 1.0 m (3.28 ft) increments
17
Analog IFMs (AIFMs), similar to groups of terminal blocks, are available with either 15- or 25-pin D-shell connectors. The number of field-side wiring terminals varies with the type of module from three to five terminals per I/O channel. AIFMs are available as feed-through or fusible to customize the wiring system to your application. All of the AIFMs have the following features:
Polarized D-shell connector (15- or 25-pin) for easy installation. Pre-wired cable has mating D-shell connector with slide-locking mechanism for secure connection.
Large rectangular write-on area acts as built-in group marking carrier for programmable controller rack, module group, and/or slot information. UL Component Recognized (File E113724 Guide NRAQ2); UL recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2); CE Approved; Factory Mutual Listed (File J.I. 3000590) FM approved Standard DIN #3 Rail mounting for quick installation.
Pre-printed and blank adhesive marking strips are provided to identify either Programmable Controller I/O field-side wiring terminals or your own application requirements.
High-density field-side wiring terminals allow more connections in less space and accommodate #2212 AWG wire.
Continuous current rating of 2 A per circuit supports higher-current programmable controller output modules. Analog IFM
18
Feed-through AIFMs have three terminals per I/O channel to wire the I/O module connections and device shield. The shield terminals are internally bussed together and also tied to the D-shell housing to connect with the cable shield. Some feed-through AIFMs also have special features (refer to page 18). The Cat. No. 1492-AIFM4-3 AIFM, when used with Cat. Nos. 1771-OFE2 and -OFE3 controllers, provides selectable current limiting resistors. Simply flip a DIP switch to add the 250 ohms series impedance into the output circuit. As a troubleshooting aid, test point loops access the circuit on either side of the series resistor and can be used to measure output circuit voltage/current. The limiting resistors are configured on a per channel basis. The Cat. No. 1492-AIFM6TC-3 AIFM for the Cat. No. 1756-IT6I controller provides on-board cold junction compensation to allow thermocouples to be connected remotely while still correcting for temperature at the termination point. The combination thermistor and isothermal bar acquires temperature data at the AIFM for the thermocouple module to adjust the input value. The Cat. No. 1492-AIFM8-3 AIFM has eight extra terminals commoned together in a power bus that can be used for Module Common connections or power supply connections. The extra terminals and internal jumpering eliminate the need for some terminal blocks for power connections and jumper accessories. Below are examples of the field-side connections available on the feed-through AIFMs.
Output
AIFM
0 LOAD
C ANL COM SH
19
Fusible AIFMs are available for analog input modules. These AIFMs enable you to fuse the input device power source on the field-side. The field-side power source is distributed through individual on-board 5 x 20 mm fuse clips. The AIFMs have 24V DC blown fuse indicators to reduce the troubleshooting time needed to locate and replace a blown fuse. Standard fuse holders that reside in the AIFM are aided in the removal of the fuse with a fuse puller (fuses are not included). Isolation switch plugs or dummy fuses (refer to Accessories, page 200) are also available to isolate an input circuit after power is removed. In addition, once the circuit has been isolated and power restored, the input loop current can be measured in 2-wire transmitter applications. The fusible AIFMs have five terminals per input channel (except Cat. No. AIFM16-F-3, which has three terminals per channel) to wire the input module connections, device shield, and power connections for 2-, 3-, and 4wire transmitters. The shield terminals are internally bussed together and also tied to the D-shell housing to connect with the cable shield. There are two separate power busses (416 terminals, depending on the AIFM) that can be used for +V and DC COM connections and/or Module Common. The extra terminals and internal connections eliminate additional terminal blocks and jumpers reducing spare parts inventory, saving panel space, and simplifying installation. All of the fusible AIFMs have on-board DIP switches to easily connect unused inputs to module common reducing wiring on the field-side. You no longer need extra jumper wires or comb-style jumpers to properly terminate unused inputs, as recommended on many Bulletin 1746, 1756, and 1771 analog input modules. Inputs are jumpered via DIP switch on a per-channel basis. The Cat. Nos. 1492-AIFM4I-F-5 and 1492-AIFM4C-F-5 AIFMs both have test point loops on either side of the fuse clips for easier access and connection of metering equipment. Metering equipment can also be attached to the fuse clips on other AIFMs for measuring input loop current.
20
2-Wire Transmitter
AIFM
+V Power Supply Transmitter V1
Pre-wired Cable
Channel 1+
4-Wire Transmitter
AIFM
+V Power Supply V1
Pre-wired Cable
Channel 1+
The Cat. No. 1492-AIFMQS AIFM is a specialized module for use with the Cat. No. 1746-QS synchronized axis module. The module has four input channels that match the input requirement of the 1746-QS, a matching output channel provided for each input channel, and power terminals that provide fused field-side device power. Extra terminals allow convenient connection for power and shield terminal connections. An example of the field-side connections is shown below.
AIFM
+ INT 1
12 24 13 25 11 23 White/Green Green/White White/Orange Orange/White White/Blue Blue/White 1 11 2 3 17 26
-INT 1
Sensor
+ RET 1
-RET 1
+OUT 1
OUT COM
Load
21
Important: The following AIFM cat. no. breakdown is for explanation purposes only. It is not a product configurator. Not all combinations of fields are valid product cat. nos. First, select the desired AIFM using the steps in Ordering Digital and Analog Wiring Systems on page 23. Then, use this breakdown for verification and explanation only.
1492AIFM 16F5
Bulletin No. No. Field-Side Wiring Terminals 3 3 per I/O channel 5 5 per input channel
No. Analog I/O Channels 4 4 channels: input, output, or 2 input/output combination 4C 4 channels: 2 input/2 output combination 4I 4 input channels 6S 6 isolated input or output channels 6TC 6 thermocouple input channels 8 8 input or output channels 16 16 input channels PI 8 input/2 output channels
Input Fuse Clips and Blown Fuse Indicators Blank No fuse clips F 5 x 20 mm fuse clips with 24V DC blown fuse indicators for output modules
22
Pre-Wired Cable Cat. No. Explanation for Bulletins 1746, 1756, and 1771 Analog I/O Modules
Bulletin No.
Important: The following analog cable cat. no. breakdown is for explanation purposes only. It is not a product configurator. All combinations of fields are not valid product cat. nos. First, select the desired AIFM using the steps in Ordering Digital and Analog Wiring Systems on page 23. Then, use this breakdown for verification and explanation only.
1492ACABLE 050 A
Analog Interface Cables Standard or Build-to-Order Length Cable 005 0.5 m (1.64 ft) 010 1.0 m (3.28 ft) 025 2.5 m (8.20 ft) 050 5.0 m (16.40 ft) 001-020 0.12.0 m (0.3286.56 ft) 0.1 m (0.328 ft increments) 020-100 2.010.0 m (6.5632.8 ft) 0.5 m (1.64 ft) increments 100-990 10.099.0 m (32.8374.72 ft) 1.0 m (3.28 ft) increments
Standard
Build-to-Order
A-Cable Type A, B, C, D, Pre-wired cables for Bulletin 1746 analog and RTD L, Q I/O modules. E, F, G, H, J Pre-wired cables for Bulletin 1771 analog and RTD I/O modules. TA, TB, TC, Pre-wired cables for Bulletin 1756 analog, RTD, and TD, UA, UB, thermocouple I/O modules. UC, UD, VA, VB, WA, WB, X, Y, Z M Pre-wired cables for Bulletin 1757 pulse input I/O modules
Pre-Wired Cable Cat. No. Explanation for Bulletin 1746 and 1769 Analog I/O Modules
Bulletin No.
Important: The following analog cable cat. no. breakdown is for explanation purposes only. It is not a product configurator. All combinations of fields are not valid product cat. nos. First, select the desired AIFM using the steps in Ordering Digital and Analog Wiring Systems on page 23. Then, use this breakdown for verification and explanation only.
Cable Type A46 Analog Interface Cables Standard or Build-to-Order Length Cable 005 0.5 m (1.64 ft) 010 1.0 m (3.28 ft) 025 2.5 m (8.20 ft) 050 5.0 m (16.40 ft) 001-020 0.12.0 m (0.3286.56 ft) 0.1 m (0.328 ft increments) 020-100 2.010.0 m (6.5632.8 ft) 0.5 m (1.64 ft) increments 100-990 10.099.0 m (32.8374.72 ft) 1.0 m (3.28 ft) increments Publication 1492-TD008A-EN-P - March 2001 AA69, AB69, BA69, BB69, BC69, BD69 Standard
Pre-wired cables for Bulletin 1746-NI16I and -NI16V analog modules. Pre-wired cables for Bulletin 1769 analog I/O modules.
Build-to-Order
23
To order the proper IFM/XIM/AIFM pre-wired cable: 1. Determine I/O platform (e.g., Bulletin 1746, 1756, 1769, 1771) and the cat. no. of the I/O module being specified. 2. Determine whether you require field-side LEDs, fusing for over-current protection, or relays (check voltage ratings for LEDs, fuse blown indication, relay, and coil). 3. Determine your field-side wiring requirements. Are extra terminals needed? 4. Determine desired cable length (0.5 m, 1.0 m, 2.5 m, 5.0 m, or build-toorder) based on wiring needs from I/O module to IFM/XIM/AIFM. 5. Refer to selection tables as follows:
Selection Table Quick Reference Platform Bulletin 1746 Digital Bulletin 1746 Analog Bulletin 1756 Digital Bulletin 1756 Analog Bulletin 1769 Digital Bulletin 1769 Analog Bulletin 1771 Digital Bulletin 1771 Analog Page No. 25 28 30 33 36 37 40 43
24
Selection Tables
25
Feedthrough
Standard Narrow standard Extra terminals 3-wire sensor type input devices
1492-IFM20F 1492-IFM20FN 1492-IFM20F-2 1492-IFM20F-3 1492-IFM20D24 1492-IFM20D24N 1492-IFM20D120 1492-IFM20D120N 1492-IFM20D24-2 1492-IFM20D24A-2 1492-IFM20D120-2 1492-IFM20D120A-2 1492-IFM20D24-3 1492-IFM20DS24-4 1492-IFM20DS120-4 1492-IFM20D240-2 1492-IFM20D240A-2 1492-IFM20F-F-2 1492-IFM20F-F24-2 1492-IFM20F-F120-2 1492-IFM20F-F240-2 1492-IFM20F-F24A-2 1492-IFM20F-F120A-2 1492-IFM20F-FS-2 1492-IFM20F-FS24-2 1492-IFM20F-FS24A-4 1492-IFM20F-FS120-2 1492-IFM20F-FS120-4
A A A A A A A
B B B B B B
B B B B
E E E E
B B B B
A A
B B B B B B
B B B B B B
B B B B B B
B B B B B B
C G C C G C
E E E E E
E E E E E
E E E E E
E E E
E E E E
E E E E
LED Standard with 24V AC/DC LEDs Indicating Narrow standard with 24V AC/DC LEDs Standard with 120V AC/DC LEDs Narrow standard with 120V AC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs Isolated with 24/48V AC/DC LEDs and 4 terminals/output Isolated with 120V AC LEDs and 4 terminals/output 240V AC LEDs and extra terminals for outputs 240V AC LEDs and extra terminals for inputs Fusible Extra terminals for outputs Extra terminals with 24V AC/DC B/F indicators Extra terminals with 120V AC B/F indicators Extra terminals with 240V AC B/F indicators Extra terminals with 24V AC/DC B/F indicators Extra terminals with 120V AC/DC B/F indicators Isolated with extra terminals for outputs Isolated with extra terminals and 24V AC/DC blown fuse indicators Isolated with four terminals/input and 24V AC/DC blown fuse indicators Isolated with extra terminals and 120V AC/DC blown fuse indicators Isolated with four terminals/output and 120V AC/DC blown fuse indicators
E E E E E
B B B B B
B B B B B
C C C C E E E E E E E E E E
A A B B B B
E E
Isolated with four terminals/input and 120V AC/DC blown fuse 1492-IFM20F-FS120A-4 indicators Isolated with four terminals/output and 240V AC/DC blown fuse indicators Relay Master 20-pin master with eight (8) 24V DC relays 20-pin master with eight (8) 120V AC relays 1492-IFM20F-FS240-4 1492-XIM2024-8R 1492-XIM20120-8R 1492-XIM24-8R 1492-XIM120-8R 1492-XIMF-F24-2 1492-XIMF-F120-2 1492-XIMF-2
E E E
CR
Relay Expander with eight (8) 24V DC relays Expander Expander with eight (8)120V AC relays Fusible 8-ch. expander with 24V DC B/F indicators Expander 8-ch. expander with 120V AC B/F indicators FeedExpander with eight feed-through channels through Expander
One expander is connected to a master to provide a total of 16 outputs. An extender cable is included with each expander to attach it to the master.
26
I/O Module Cat. No. 1746- OB32E H H H H H H OB32 OV32 H H H H H H IB32 IV32 H H H H H H
Feed-through
LED Indicating
Fusible
Standard Extra terminals 3-wire sensor type input devices Standard with 24V AC/DC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs Isolated with 24/48V AC/DC LEDs and four terminals/output Isolated with 24V AC/DC LEDs and four terminals/input Isolated with 120V AC LEDs and four terminals/output Isolated with 120V AC LEDs and four terminals/input Isolated with 240V AC LEDs and four terminals/input Extra terminals for outputs Extra terminals with 24V AC/DC blown fuse indicators Extra terminals with 120V AC blown fuse indicators Isolated with extra terminals for outputs Isolated with extra terminals and 24V AC/DC blown fuse indicators Isolated with 24V AC/DC blown fuse indicators and four terminals/output Isolated with extra terminals and 120V AC/DC blown fuse indicators Isolated with 120V AC/DC blown fuse indicators and four terminals/output Isolated with 240V AC/DC blown fuse indicators and four terminals/output Isolated with 24V AC/DC blown fuse indicators and four terminals/input Isolated with 120V AC/DC blown fuse indicators and four terminals/input 40-pin master with eight (8) 24V DC relays 40-pin master with sixteen (16) 24V DC relays Expander with eight (8) 24V DC relays Expander with eight (8) 120V AC relays 8-channel expander with 24V DC blown fuse indicators 8-channel expander with 120V AC blown fuse indicators Expander with eight feed-through channels
1492-IFM40F 1492-IFM40F-2 1492-IFM40F-3 1492-IFM40D24 1492-IFM40D24-2 1492-IFM40D24A-2 1492-IFM40D120-2 1492-IFM40D120A-2 1492-IFM40D24-3 1492-IFM40DS24-4 1492-IFM40DS24A-4 1492-IFM40DS120-4 1492-IFM40DS120A-4 1492-IFM40DS240A-4 1492-IFM40F-F-2 1492-IFM40F-F24-2 1492-IFM40F-F120-2 1492-IFM40F-FS-2 1492-IFM40F-FS24-2 1492-IFM40F-FS24-4 1492-IFM40F-FS120-2 1492-IFM40F-FS120-4 1492-IFM40F-FS240-4 1492-IFM40F-FS24A-4 1492-IFM40F-FS120A-4 1492-XIM4024-8R 1492-XIM4024-16R 1492-XIM24-8R 1492-XIM120-8R 1492-XIMF-F24-2 1492-XIMF-F120-2 1492-XIMF-2
H H H H H H
H H H H H H
H H H H
Two or three expanders can be connected to a master to provide a total of 32 outputs. An extender cable is included with each expander to connect it to the master.
27
Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE005N is for a 0.5 m cable that could be used to connect a Cat. No. 1492-IFM20D24N IFM to a Cat. No. 1746-OW16 I/O module. Build-to-order lengths are also available.
The I/O module-ready cables have a pre-wired RTB on one end to plug onto the front of a Bulletin 1746 I/O module and 20 or 40 individually colored #18 AWG conductors on the other end. These cables provide the convenience of pre-wired connections at the I/O module end, while still allowing the flexibility to field-wire to standard terminal blocks of your choice.
Cables are available in standard lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE050RTBR is for a 5.0 m cable with a pre-wired Cat. No. 1746-RT25R RTB on one end.
Note: The following I/O Modules do not have RTBs: 1746-IA4, 1746-IA8, 1746-IB8, 1746-IM4, 1746-IM8, 1746-IV8, 1746-OA8, 1746-OB8.
28
I/O Module Cat. No. 1746- NIO4V NI16V A46 A46 FIO4V NO4V NIO4I NI16I A46 A46 FIO4I NO4I NR4 D NI4 NI8 QS Q
Feed-through
Thermocouple Fusible
4-channel with 3 terminals/channel 6-channel isolated with 34 terminals/channel 8-channel with 3 terminals/channel 6-channel with 3 terminals/channel 2-channel with 24V blown fuse indicators, test points, 5 terminals/input, 3 terminals/output 4-channel with 24V blown fuse indicators, test points, 5 terminals/input 8-channel with 24V blown fuse indicators, 5 terminals/channel 16-channel with 24V blown fuse indicators, 3 terminals/channel 16-channel with 24V blown fuse indicators, 5 terminals/channel 4-input/4-output channel with 8 fuses and 24V blown fuse indicators
1492-AIFM4-3 1492-AIFM6S-3 1492-AIFM8-3 1492-AIFM6TC-3 1492-AIFM4C-F-5 1492-AIFM4I-F-5 1492-AIFM8-F-5 1492-AIFM16-F-3 1492-AIFM16-F-5 1492-AIFMQS
L L
L L
C C
L L
L L
These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1746 analog I/O module and a connector on the other end to plug into a 20- or 40-terminal IFM. To use this table, you must first have selected an IFM from the preceding table.
To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-ACABLE005A is for a 0.5 m cable that could be used to connect a Cat. No. 1492-AIFM4I-F-5 IFM to a Cat. No. 1746-NI4 I/O module.
29
30
Feedthrough
LED Indicating
Fusible
Standard Narrow standard Extra terminals 3-wire sensor type input devices Standard with 24V AC/DC LEDs Narrow standard with 24V AC/DC LEDs Standard with 120V AC/DC LEDs Narrow standard with 120V AC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs Isolated with 24/48V AC/DC LEDs and 4 terminals/output Isolated with 120V AC LEDs and 4 terminals/output 240V AC LEDs and extra terminals for outputs 240V AC LEDs and extra terminals for inputs Extra terminals for outputs Extra terminals with 24V AC/DC blown fuse indicators Extra terminals with 120V AC blown fuse indicators Extra terminals with 240V AC blown fuse indicators Extra terminals with 24V AC/DC blown fuse indicators Extra terminals with 120V AC/DC blown fuse indicators Isolated with extra terminals for outputs Isolated with extra terminals and 24V AC/DC blown fuse indicators Isolated with 4 terminals/input and 24V AC/DC blown fuse indicators Isolated with extra terminals and 120V AC/DC blown fuse indicators Isolated with 4 terminals/output and 120V AC/DC blown fuse indicators Isolated with 4 terminals/input and 120V AC/DC blown fuse indicators Isolated with 4 terminals/output and 240V AC/DC blown fuse indicators 20-pin master with eight (8) 24V DC relays 20-pin master with eight (8) 120V AC relays Expander with eight (8) 24V DC relays Expander with eight (8) 120V AC relays Expander with eight (8) 24V channels with blown fuse indicators Expander with eight (8) 120V channels with blown fuse indicators Expander with eight (8) feed-through channels
1492-IFM20F 1492-IFM20FN 1492-IFM20F-2 1492-IFM20F-3 1492-IFM20D24 1492-IFM20D24N 1492-IFM20D120 1492-IFM20D120N 1492-IFM20D24-2 1492-IFM20D24A-2 1492-IFM20D120-2 1492-IFM20D120A-2 1492-IFM20D24-3 1492-IFM20DS24-4 1492-IFM20DS120-4 1492-IFM20D240-2 1492-IFM20D240A-2 1492-IFM20F-F-2 1492-IFM20F-F24-2 1492-IFM20F-F120-2 1492-IFM20F-F240-2 1492-IFM20F-F24A-2 1492-IFM20F-F120A-2 1492-IFM20F-FS-2 1492-IFM20F-FS24-2 1492-IFM20F-FS24A-4 1492-IFM20F-FS120-2 1492-IFM20F-FS120-4 1492-IFM20F-FS120A-4 1492-IFM20F-FS240-4 1492-XIM2024-8R 1492-XIM20120-8R 1492-XIM24-8R 1492-XIM120-8R 1492-XIMF-F24-2 1492-XIMF-F120-2 1492-XIMF-2
U U U U U U U
X X X X X X X X
X X X X X X X X X
X X X X
X X X X X X X X X
U U U W W W W W
U U U V V V V
U U U V V V V
X X X X X X X X X
U U U W W W
X X X X X X X X X
U U U W W W
One expander module is connected to a master to provide a total of 16 outputs. An extender cable is included with each expander to connect it to the master.
31
Feedthrough
Standard Extra terminals 3-wire sensor type input devices Standard with 24V AC/DC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs Isolated with 24/48V AC/DC LEDs and 4 terminals/output Isolated with 24V AC/DC LEDs and 4 terminals/input Isolated with 120V AC LEDs and 4 terminals/output Isolated with 120V AC LEDs and 4 terminals/input Isolated with 240V AC LEDs and 4 terminals/input
1492-IFM40F 1492-IFM40F-2 1492-IFM40F-3 1492-IFM40D24 1492-IFM40D24-2 1492-IFM40D24A-2 1492-IFM40D120-2 1492-IFM40D120A-2 1492-IFM40D24-3 1492-IFM40DS24-4 1492-IFM40DS24A-4 1492-IFM40DS120-4 1492-IFM40DS120A-4 1492-IFM40DS240A-4 1492-IFM40F-F-2 1492-IFM40F-F24-2 1492-IFM40F-F120-2 1492-IFM40F-FS-2 1492-IFM40F-FS24-2 1492-IFM40F-FS24-4 1492-IFM40F-FS120-2 1492-IFM40F-FS120-4 1492-IFM40F-FS240-4 1492-IFM40F-FS24A-4 1492-IFM40F-FS120A-4 1492-XIM4024-8R 1492-XIM4024-16R 1492-XIM24-8R 1492-XIM120-8R 1492-XIMF-F24-2 1492-XIMF-F120-2 1492-XIMF-2
Z Z Z
LED Indicating
Z Y Y Y Y Y Y Y Y Y
Fusible
Extra terminals for outputs Extra terminals with 24V AC/DC blown fuse indicators Extra terminals with 120V AC blown fuse indicators Isolated with extra terminals for outputs Isolated with extra terminals and 24V AC/DC blown fuse indicators Isolated with 24V AC/DC blown fuse indicators and 4 terminals/output Isolated with extra terminals and 120V blown fuse indicators Isolated with 120V AC/DC blown fuse indicators and 4 terminals/output Isolated with 240V AC/DC blown fuse indicators and 4 terminals/output Isolated with 24V AC/DC blown fuse indicators and 4 terminals/input Isolated with 120V AC/DC blown fuse indicators and 4 terminals/input
Z Z Y Y Y Y Y Y Y Y
Y Y Y Y Y Y Y Y Y Y Y
Y Y
40-pin master with eight (8) 24V DC relays 40-pin master with sixteen (16) 24V DC relays Expander with eight (8) 24V DC relays Expander with eight (8) 120V AC relays 8-channel expander with 24V DC blown fuse indicators 8-channel expander with 120V AC blown fuse indicators Expander with eight (8) feed-through channels
Z Z
Two or three expander modules are connected to a master to provide a total of 32 outputs. An extender cable is included with each expander to connect it to the master.
32
Pre-Wired Cables for Bulletin 1756 Digital I/O Modules Cable Cat. No. 1492-CABLEU 1492-CABLEV 1492-CABLEW 1492-CABLEX 1492-CABLEY 1492-CABLEZ Standard Cable Lengths 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m Build-to-Order Available Yes Yes Yes Yes Yes Yes No. of Mating 1756 Conductors I/O Module Cat. No. 20 20 20 20 40 40 1756-IA8D, -OA8, -OA8D, -OA8E, -OB8, -OC8, -ON8 1756-OA8D, -OA8E 1756-OA8, -OBE, -OC8, -ON8 1756-IA16, -IB16, -IC16, -IN16, -OA16, -OB16E 1756-IA16I, -IB16D, -IB16I, -IH16, -OA16I, -OB8EI, -OB16D, -OB16I, -OH8I, -OW16I, -OX8I 1756-IB32, -OB32
Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE005Y is for a 0.5 m cable that could be used to connect a Cat. No. 1492-IFM40F IFM to a Cat. No. 1756-IA16I I/O module.
The I/O module-ready cables have a pre-wired RTB on one end to plug onto the front of a Bulletin 1756 I/O module and 20 or 40 individually colored #18 AWG conductors on the other end. These cables provide the convenience of pre-wired connections at the I/O module end, while still allowing the flexibility to field-wire to standard terminal blocks of your choice.
I/O Module-Ready Cables for Bulletin 1756 Digital I/O Modules Cable Cat. No. 1492-CABLETBNH 1492-CABLETBCH Standard Cable Lengths 1.0, 2.5, 5.0 m 1.0, 2.5, 5.0 m Build-to-Order Available Yes Yes No. of Mating 1756 Conductors I/O Module Cat. No. 20 40 1756-IA8D, -IA16, -IB16, -IC16, -IN16, -OA8, -OA8D, -OA8E, -OA16, -OB8, -OB16E, -OC8, -ON8 1756-IA16I, -IB16D, -IB16I, -IB32, -IF16, -IH16I, -IM16I, -OA16I, -OB8EI, -OB16D, -OB16I, -OB32, -OH8I, -OW16I, -OX8I
Cables are available in standard lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE050TBNH is for a 5.0 m cable with a pre-wired Cat. No. 1756-TBNH RTB on one end.
33
I/O Module Cat. No. 1756- IF16 (Sgl-End Volt) IF16 (Diff Voltage) IF16 (Diff current) IF16 (Sgl-End Crt) IF8 (Sgl-End Volt) IF8 (Diff Voltage) IF8 (Diff Current) IF8 (Sgl-End Crt) Cat. No. 1757-
OF4 (Voltage)
OF8 (Voltage)
IF6I (Voltage)
OF4 (Current)
OF8 (Current) WB
IF6I (Current)
OF6CI
OF6VI
Feed-through
4-channel with 3 terminals/ channel 6-channel isolated with 34 terminals/ channel 8-channel with 3 terminals/ channel
1492-AIFM4-3
VA
VB
1492-AIFM6S-3
1492-AIFM8-3
TA
TB
TC
TD
UA
UB
UC
UD
WA
Thermocouple
6-channel with 3 terminals/ channel 8-channel with 5 terminals/ channel 16-channel with 3 terminals/ channel 16-channel with 5 terminals/ channel 8 input/2 output channels
1492-AIFM6TC-3
Fusible
1492-AIFM8-F-5
TA
TB
TC
TD
UC
UD
1492-AIFM16-F-3
UA
UB
UC
UD
1492-AIFM16-F-5
UA
UB
UC
UD
1492-AIFMPI
Some analog I/O modules can be operated in up to four modes (current/voltage, single-ended/differential) based on connections. In all cases, each channel is factory-configured for the same mode. However, you can field configure any channel for another mode.
PIM M
IR6I
IT6I
34
Pre-Wired Cables for 1756 Analog I/O Modules Cable Cat. No. 1492-ACABLEM 1492-ACABLEX 1492-ACABLEY 1492-ACABLEZ 1492-ACABLETA 1492-ACABLETB 1492-ACABLETC 1492-ACABLETD 1492-ACABLEUA 1492-ACABLEUB 1492-ACABLEUC 1492-ACABLEUD 1492-ACABLEVA 1492-ACABLEVB 1492-ACABLEWA 1492-ACABLEWB Standard Cable Lengths 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m Build-to-Order Available Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes AIFM Connector 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 15-pin D-shell 15-pin D-shell 25-pin D-shell 25-pin D-shell Mating 1756 I/O Module Cat. No. 1757-PIM 1756-IF16 Current 1756-IF16 Voltage, -IT6I, -OF6CI, -OF6VI 1756-IR16 1756-IF8 Single-Ended Voltage 1756-IF8 Single-Ended Current 1756-IF8 Differential Voltage 1756-IF8 Differential Current 1756-IF16 Single-Ended Voltage 1756-IF16 Single-Ended Current 1756-IF16 Differential Voltage 1756-IF16 Differential Current 1756-OF4 Voltage 1756-OF4 Current 1756-OF8 Voltage 1756-OF8 Current
Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-ACABLE005Y is for a 0.5 m cable that could be used to connect a Cat. No. 1492-AIFM6TC-3 analog IFM to a Cat. No. 1756-IT6I I/O module.
35
36
Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500 IFMs and Cables
I/O Module Cat. No. 1769- OW8I D69 D69 D69 D69 D69 D69 D69 D69 OB16 OV16 E69 E69 E69 E69 E69 E69 E69 E69 IM12 IA16 OW8 C69 C69 C69 C69 C69 C69 C69 C69 C69 IA8I IQ16 OA8 C69 C69 C69 C69 C69 C69 C69
Feed-through
LED Indicating
Fusible
Standard Narrow standard Extra terminals 3-wire sensor type input devices Standard with 24V AC/DC LEDs Narrow standard with 24V AC/DC LEDs Standard with 120V AC/DC LEDs Narrow standard with 120V AC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs Isolated with 24/48V AC/DC LEDs and 4 terminals/output Isolated with 120V AC LEDs and 4 terminals/output 240V AC LEDs and extra terminals for outputs 240V AC LEDs and extra terminals for inputs Extra terminals for outputs Extra terminals with 24V AC/DC blown fuse indicators Extra terminals with 120V AC blown fuse indicators Extra terminals with 240V AC blown fuse indicators Extra terminals with 24V AC/DC blown fuse indicators Extra terminals with 120V AC blown fuse indicators Isolated with extra terminals for outputs Isolated with extra terminals and 24V AC/DC blown fuse indicators Isolated with 4 terminals/input and 24V AC/DC blown fuse indicators Isolated with extra terminals and 120V AC/DC blown fuse indicators Isolated with 4 terminals/output and 120V AC/DC blown fuse indicators Isolated with 4 terminals/input and 120V AC/DC blown fuse indicators Isolated with 4 terminals/output and 240V AC/DC blown fuse indicators 20-pin master with eight (8) 24V DC relays 20-pin master with eight (8) 120V AC relays Expander with eight (8) 24V DC relays Expander with eight (8) 120V AC relays 8-channel expander with 24V DC blown fuse indicators 8-channel expander with 120V AC blown fuse indicators Expander with eight (8) feed-through channels
1492-IFM20F 1492-IFM20FN 1492-IFM20F-2 1492-IFM20F-3 1492-IFM20D24 1492-IFM20D24N 1492-IFM20D120 1492-IFM20D120N 1492-IFM20D24-2 1492-IFM20D24A-2 1492-IFM20D120-2 1492-IFM20D120A-2 1492-IFM20D24-3 1492-IFM20DS24-4 1492-IFM20DS120-4 1492-IFM20D240-2 1492-IFM20D240A-2 1492-IFM20F-F-2 1492-IFM20F-F24-2 1492-IFM20F-F120-2 1492-IFM20F-F240-2 1492-IFM20F-F24A-2 1492-IFM20F-F120A-2 1492-IFM20F-FS-2 1492-IFM20F-FS24-2 1492-IFM20F-FS24A-4 1492-IFM20F-FS120-2 1492-IFM20F-FS120-4 1492-IFM20F-FS120A-4 1492-IFM20F-FS240-4 1492-XIM2024-8R 1492-XIM20120-8R 1492-XIM24-8R 1492-XIM120-8R 1492-XIMF-F24-2 1492-XIMF-F120-2 1492-XIMF-2
F69 F69
Sink mode only. One expander module is connected to a master to provide a total of 16 outputs. An extender cable is included with each expander to connect it to the master.
37
Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500 IFMs and Cables, Continued
These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1769 digital I/O module and a connector on the other end to plug into a 20-terminal IFM/XIM. You must first select the IFM/XIM from the preceding selection table.
Pre-Wired Cables for Bulletin 1769 Digital I/O Modules Cable Cat. No. 1492-CABA69 1492-CABB69 1492-CABC69 1492-CABD69 1492-CABE69 1492-CABF69 1492-CABG69 Standard Cable Lengths 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m Build-to-Order Available Yes Yes Yes Yes Yes Yes Yes No. of Conductors 20 20 20 20 20 20 20 Mating 1746 I/O Module Cat. No. 1769-IA16 1769-IQ16 1769-OA8, -OW8 1769-OW8I 1769-OB16, -OV16 1769-IA8I 1769-IM12
Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CAB005E69 is for a 0.5 m cable that can be used to connect a Cat. No. 1492-IFM20D24N IFM to a Cat. No. 1769-OB16 I/O module.
The I/O module-ready cables have a pre-wired RTB on one end to plug onto the front of a Bulletin 1769 I/O module and 20 individually colored #18 AWG conductors on the other end. These cables provide the convenience of pre-wired connections at the I/O module end, while still allowing the flexibility to field-wire to standard terminal blocks of your choice.
I/O Module-Ready Cables for Bulletin 1769 Digital I/O Modules Cable Cat. No. 1492-CABRTN10 1492-CABRTN18 Standard Cable Lengths 1.0, 2.5, 5.0 m 1.0, 2.5, 5.0 m Build-to-Order Available Yes Yes No. of Conductors 10 18 Mating 1746 I/O Module Cat. No. 1769-OA8, -OW8 1769-IA8I, -IA16, -IQ16, -OB16, -OV16, -OW8I, -IM12
Cables are available in standard lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CAB050RTN10 is for a 5.0 m cable with a wired Cat. No. 1746-RTBN10 on one end.
38
Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500 AIFMs and Cables
I/O Module Cat. No. 1769- OF2 OF2 (Voltage) (Current) AA69 AB69
1492-AIFM4-3 1492-AIFM6S-3 1492-AIFM6TC-3 1492-AIFM8-3 1492-AIFM4I-F-5 1492-AIFM4C-F-5 1492-AIFM8-F-5 1492-AIFM16-F-3 1492-AIFM16-F-5 1492-AIFMQS
These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1769 analog I/O module and a connector on the other end to plug into a 20-terminal AIFM. You must first select the AIFM from the preceding selection table.
Pre-Wired Cables for Bulletin 1769 Analog I/O Modules Cable Cat. No. 1492-ACABAA69 1492-ACABAB69 1492-ACABBA69 1492-ACABBB69 1492-ACABBC69 1492-ACABBD69 Standard Cable Lengths 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m Build-to-Order Available Yes Yes Yes Yes Yes Yes AIFM Connector 15-pin D-shell 15-pin D-shell 15-pin D-shell 15-pin D-shell 15-pin D-shell 15-pin D-shell Mating 1769 I/O Module Cat. No. 1769-OF2 Voltage 1769-OF2 Current 1769-IF4 Single-Ended Voltage 1769-IF4 Single-Ended Current 1769-IF4 Differential Voltage 1769-IF4 Differential Current
Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-ACAB005 is for a 0.5 m cable.
39
40
IFMs for Bulletin 1771 Digital 8-Point and 16-Point I/O Modules
OMD Type of IFM Description of 20-Terminal IFM IFM Cat. No. I/O Module Cat. No. 1771- OND F F OAD OBD OGD IMD F F F IND IAD IBD IGD ICD IA2 IN IA IB IH IT
Feedthrough
Standard Narrow standard Extra terminals 3-wire sensor type input devices
1492-IFM20F 1492-IFM20FN 1492-IFM20F-2 1492-IFM20F-3 1492-IFM20D24 1492-IFM20D24N 1492-IFM20D120 1492-IFM20D120N 1492-IFM20D24-2 1492-IFM20D24A-2 1492-IFM20D120-2 1492-IFM20D120A-2 1492-IFM20D24-3 1492-IFM20DS24-4 1492-IFM20DS120-4 1492-IFM20D240-2 1492-IFM20D240A-2 1492-IFM20F-F-2 1492-IFM20F-F24-2 1492-IFM20F-F120-2 1492-IFM20F-F240-2 1492-IFM20F-F24A-2 1492-IFM20F-F120A-2 1492-IFM20F-FS-2 1492-IFM20F-FS24-2 1492-IFM20F-FS24A-4 1492-IFM20F-FS120-2 1492-IFM20F-FS120-4 1492-IFM20F-FS120A-4 1492-IFM20F-FS240-4 1492-XIM2024-8R 1492-XIM20120-8R 1492-XIM24-8R 1492-XIM120-8R 1492-XIMF-F24-2 1492-XIMF-F120-2 1492-XIMF-2
F F F F F F F F
F F F F F F F F F
F F F F F F F F F
F F F F
F F F F F F F F
F F F
F F
F F F
F F F F
LED Indicating
Standard with 24V AC/DC LEDs Narrow standard with 24V AC/DC LEDs Standard with 120V AC/DC LEDs Narrow standard with 120V AC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs Isolated with 24/48V AC/DC LEDs and 4 terminals/output Isolated with 120V AC LEDs and 4 terminals/output 240V AC LEDs and extra terminals for outputs 240V AC LEDs and extra terminals for inputs
Fusible
Extra terminals for outputs Extra terminals with 24V AC/DC blown fuse indicators Extra terminals with 120V AC blown fuse indicators Extra terminals with 240V AC blown fuse indicators Extra terminals with 24V AC/DC blown fuse indicators Extra terminals with 120V AC/DC blown fuse indicators Isolated with extra terminals for outputs Isolated with extra terminals and 24V AC/DC blown fuse indicators Isolated with 4 terminals/input and 24V AC/DC blown fuse indicators Isolated with extra terminals and 120V AC/DC blown fuse indicators Isolated with 4 terminals/output and 120V AC/DC blown fuse indicators Isolated with 4 terminals/input and 120V AC/DC blown fuse indicators Isolated with 4 terminals/output and 240V AC/DC blown fuse indicators
20-pin master with eight (8) 24V DC relays 20-pin master with eight (8) 120V AC relays Expander with eight (8) 24V DC relays Expander with eight (8) 120V AC relays 8-channel expander with 24V DC blown fuse indicators 8-channel expander with 120V AC blown fuse indicators Expander with eight (8) feed-through channels
Either F or FF. One expander is connected to a master to provide a total of 16 outputs. An extender cable is included with each expander to connect it to the master.
41
IFMs for Bulletin 1771 Digital 16-Point Isolated and 32-Point I/O Modules
Type of IFM Description of 40-Terminal IFM IFM Cat. No. I/O Module Cat. No. 1771- OWNA L L L L L L L L OW16 OWN L L L L L L L L OD16 OQ16 M M M M OAN OBN ODD M M M OVN ID16 IQ16 M M IAN IBN IVN K K K K K K
Fusible
Standard Extra terminals 3-wire sensor type input devices Standard with 24V AC/DC LEDs 24V AC/DC LEDs and extra terminals for outputs 24V AC/DC LEDs and extra terminals for inputs 120V AC LEDs and extra terminals for outputs 120V AC LEDs and extra terminals for inputs 3-wire sensor with 24V AC/DC LEDs Isolated with 24/48V AC/DC LEDs and 4 terminals/output Isolated with 24V AC/DC LEDs and 4 terminals/input Isolated with 120V AC LEDs and 4 terminals/output Isolated with 120V AC LEDs and 4 terminals/input Isolated with 240V AC LEDs and 4 terminals/input Extra terminals for outputs Extra terminals with 24V AC/DC blown fuse indicators Extra terminals with 120V AC blown fuse indicators Isolated with extra terminals for outputs Isolated with extra terminals and 24V AC/DC blown fuse indicators Isolated with 24V AC/DC blown fuse indicators and 4 terminals/output Isolated with extra terminals and 120V blown fuse indicators Isolated with 120V AC/DC blown fuse indicators and 4 terminals/output Isolated with 240V AC/DC blown fuse indicators and 4 terminals/output Isolated with 24V AC/DC blown fuse indicators and 4 terminals/input Isolated with 120V AC/DC blown fuse indicators and 4 terminals/input 40-pin master with eight (8) 24V DC relays 40-pin master with sixteen (16) 24V DC relays Expander with eight (8) 24V DC relays Expander with eight (8) 120V AC relays 8-channel expander with 24V DC blown fuse indicators 8-channel expander with 120V AC blown fuse indicators Expander with eight (8) feed-through channels
1492-IFM40F 1492-IFM40F-2 1492-IFM40F-3 1492-IFM40D24 1492-IFM40D24-2 1492-IFM40D24A-2 1492-IFM40D120-2 1492-IFM40D120A-2 1492-IFM40D24-3 1492-IFM40DS24-4 1492-IFM40DS24A-4 1492-IFM40DS120-4 1492-IFM40DS120A-4 1492-IFM40DS240A-4 1492-IFM40F-F-2 1492-IFM40F-F24-2 1492-IFM40F-F120-2 1492-IFM40F-FS-2 1492-IFM40F-FS24-2 1492-IFM40F-FS24-4 1492-IFM40F-FS120-2 1492-IFM40F-FS120-4 1492-IFM40F-FS240-4 1492-IFM40F-FS24A-4 1492-IFM40F-FS120A-4 1492-XIM4024-8R 1492-XIM4024-16R 1492-XIM24-8R 1492-XIM120-8R 1492-XIMF-F24-2 1492-XIMF-F120-2 1492-XIMF-2
J J J
J J J J J J
M M
L L L L L
L L L L L L
M M M
L R L R L L L L R71 R71
M M R71 M M M M L L
Two or three expanders are connected to a master to provide a total of 32 outputs. An extender cable is included with each expander to connect it to the master. Cable Cat. No. 1492-CABR71 has only the N.O. contacts connected.
42
Pre-Wired Cables for Bulletin 1771 Digital I/O Modules Cable Cat. No. 1492-CABLEF 1492-CABLEFF 1492-CABLEJ 1492-CABLEK 1492-CABLEL 1492-CABLEM 1492-CABLER 1492-CABR71 1492-CABLET Standard Cable Lengths 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m Build-to-Order Available Yes Yes Yes Yes Yes Yes Yes Yes Yes No. of Conductors 20 20 40 40 40 40 40 40 20 Mating 1771 I/O Modules Cat. No. 1771-IAD, -IBD, -ICD, -IGD, -IND, -OAD, -OBD, -OGD, -OMD, -OND, -IMD 1771-OAD, -OBD, -OND 1771-IAN, -IBN 1771-IVN 1771-OAN, -OBN, -OVN, -OWN, -OWNA 1771-ID16, -IQ16, -OD16, -ODD, -OQ16 1771-OW16 1771-OW16 1771-IA, -IA2, -IB, -IH, -IN, -IT
Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE005M is for a 0.5 m cable that could be used to connect a Cat. No. 1492-IFM40F IFM to a Cat. No. 1771-ODD I/O module. Cable Cat. No. 1492-CABR71 has only the N.O. contacts connected.
The I/O module-ready cables have a wiring arm on one end to plug onto the front of a Bulletin 1771 I/O module and 20 or 40 individually colored #18 AWG conductors on the other end. These cables provide the convenience of pre-wired connections at the I/O module end, while still allowing the flexibility to field-wire to standard terminal blocks of your choice.
I/O Module-Ready Cables for 1771 Digital I/O Modules Cable Cat. No. 1492-CABLEWA Standard Build-to-Order No. of Mating 1771 Cable Lengths Available Conductors I/O Modules Cat. No. 1.0, 2.5, 5.0 m Yes 12 1771-IA, -IA2, -IB, -IC, -IH, -IM, -IN, -IT, -IV, -OA, -OB, -OC, -OM, -ON, -OP 1492-CABLEWD 1.0, 2.5, 5.0 m Yes 12 1771-ID, -ID01, -OD, -ODZ, -OR, -OW, -OYL, -OZL 1492-CABLEWH 1.0, 2.5, 5.0 m Yes 20 1771-IAD, -IBD, -ICD, -IGD, -IMD, -IND, -OAD, -OBD, -OGD, -OMD, -OND 1492-CABLEWHF 1.0, 2.5, 5.0 m Yes 20 1771-IBD , -OAD , -OBD , -OMD , -OND 1492-CABLEWN 1.0, 2.5, 5.0 m Yes 40 1771-IAN, -IBN, -ID16, -IQ16, -IV16, -OAN, -OBN, -OD16, -ODD, -OQ16, -OVN, -OW16, -OWN, -OWNA
Cables are available in standard lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE050WN is for a 5.0 m cable with a pre-wired Cat. No. 1771-WN wiring arm on one end. Includes an optional 3A fuse in the Wiring Arm for 1771 PLC mating I/O Modules.
43
OFE1
OFE2 G
Feed-through
Thermocouple Fusible
4-channel with 3 terminals/channel 6-channel isolated with 34 terminals/channel 8-channel with 3 terminals/channel 6-channel with 3 terminals/channel 8-channel with 5 terminals/channel 16-channel with 3 terminals/channel 16-channel with 5 terminals/channel
J E F H E F F
These pre-wired cables have a wiring arm on one end to connect to the front of a Bulletin 1771 analog I/O module and a connector on the other end to plug into a 20- or 40-terminal IFM. You must first select the IFM from the preceding selection table.
Pre-Wired Cables for Bulletin 1771 Analog I/O Modules Cable Cat. No. 1492-ACABLEE 1492-ACABLEF 1492-ACABLEG 1492-ACABLEH 1492-ACABLEJ Standard Cable Lengths 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m 0.5, 1.0, 2.5, 5.0 m Build-to-Order Available Yes Yes Yes Yes Yes AIFM Connector 25-pin D-shell 25-pin D-shell 15-pin D-shell 25-pin D-shell 25-pin D-shell Mating 1771 I/O Modules 1771-IFE Differential 1771-IFE Single-Ended 1771-OFE1, -OFE2, -OFE3 1771-IL 1771-IR
Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-ACABLE005E is for a 0.5 m cable that could be used to connect a Cat. No. 1492-AIFM8-3 IFM to a Cat. No. 1771-IFE I/O module. Build-to-order lengths are also available.
OFE3
IR
IL
44
IFM-Ready I/O Cable Cable Cat. No. 1492-CABLEP 1492-CABLEQ Standard Cable Lengths 1.0, 2.5, 5.0 m 1.0, 2.5, 5.0 m Insulation Rating 300V, 80C 300V, 80C No. Conductors 20 40 Conductor Nominal Outer Size Diameter 22 AWG 22 AWG 9 mm (0.36 in.) 11.7 mm (0.46 in.) Current/ Conductor 2A 2A Compatible IFM Cat. Nos. 1492-IFM20, 1492-XIM20 1492-IFM40, 1492-XIM40
Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025P is for a 2.5 m, 20 conductor IFM-ready cable. Also refer to Build-to-Order Length Cables on page 44.
All Bulletin 1492 cables are available in build-to-order lengths. Consult your local Allen-Bradley Sales Office or distributor for availability.
45
IFM Cat. No. 1492-IFM20F-F240-2 1492-IFM20F-FS-2 1492-IFM20F-FS24-2 1492-IFM20F-FS24A-4 1492-IFM20F-FS120-2 1492-IFM20F-FS120-4 1492-IFM20F-FS120A-4 1492-IFM20F-FS240-4 1492-IFM40F 1492-IFM40F-2 1492-IFM40F-3 1492-IFM40D24 1492-IFM40D24-2 1492-IFM40D24A-2 1492-IFM40D120-2 1492-IFM40D120A-2 1492-IFM40D24-3 1492-IFM40DS24-4 1492-IFM40DS24A-4 1492-IFM40DS120-4 1492-IFM40DS120A-4 1492-IFM40DS240A-4
Page No. for Adhesive Label Card 169 177 177 178 177 169 178 169 165 172 179 165 172 172 172 172 179 182 182 182 182 182
IFM Cat. No. 1492-IFM40F-F-2 1492-IFM40F-F24-2 1492-IFM40F-F120-2 1492-IFM40F-FS-2 1492-IFM40F-FS24-2 1492-IFM40F-FS24-4 1492-IFM40F-FS120-2 1492-IFM40F-FS120-4 1492-IFM40F-FS240-4 1492-IFM40F-FS24A-4 1492-IFM40F-FS120A-4 1492-XIM4024-16R 1492-XIM4024-8R 1492-XIM2024-8R 1492-XIM20120-8R 1492-XIM24-8R 1492-XIM120-8R 1492-XIMF-F24-2 1492-XIMF-F120-2 1492-XIMF-2
Page No. for Specifications, Application Notes, and Pinout 90 91 92 93 94 95 96 97 98 99 100 101 103 105 106 107 109 111 113 115
Page No. for Adhesive Label Card 172 172 172 183 183 184 183 185 184 185 185 189 186 186 186 187 187 188 188 188
For all IFM dimensions, refer to page 152. For all XIM dimensions, refer to page 158. For general Adhesive Label Card information, refer to page 162. For Field-Side Wiring Diagrams, refer to the Wiring System web page at http://www.ab.com/catalogs/b113. Refer to page 202 for specific platform web site information. Refer to the online documentation for new product information.
Symbols and Terminal Identification Conventions Used Throughout the Pinout Section
Fuse and Blown Fuse Indicator (where applicable) LED Circuit LED Indicator Connector Pin Field-Side Terminal N.C./N.O. Relay Contact
~ ~
46
1492-IFM20F
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. 2. Wiring Refer to the Label Section on page 163. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Dimensions Refer to page 152.
Pinout
1 2 A1 A2 A3
18 19 20
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
47
1492-IFM20FN
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. 2. Wiring Refer to the Label Section on page 174. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Dimensions Refer to page 152.
Pinout
2 11 B1 B2
1 3
A1 A2
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
10 19
A9 A10
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
48
1492-IFM20F-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. 2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The power bus is isolated into two groups of 10 terminals. This allows each group of the I/O devices to reference a different power source. 4. Dimensions Refer to page 153.
Pinout
1492-IFM20F-2 Specifications Approvals
UL Component Recognized (File E113724 Guide NRAQ2) CSA Certified (File LR1234 Class 321107) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 0264V AC/DC 600Vp
1 2 3 B1 B2 B3
18 19 20
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
A1 A2
A11 A12
2A 12 A 10 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
A9 A10 A19 A20
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
49
1492-IFM20F-3
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. 2. Wiring Refer to the Label Section on page 171. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The power busses are connected to one common (one bus has 17 terminals, and one bus has 18 terminals). All of the input devices used must reference the same power source. 4. Dimensions Refer to page 153.
Pinout
1492-IFM20F-3 Specifications Approvals
UL Component Recognized (File E113724 Guide NRAQ2) CSA Certified (File LR1234 Class 321107) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 0132V AC/DC 600Vp
3 C1
18
C16
B1 B2 20
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
B17 B18
2A 12 A
A1 A2
A16
17 (bottom row). 18 (middle row) #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
A17 1 A18
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
50
1492-IFM20D24
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load). 2. Wiring The LEDs are powered from the two-position terminal block. Make only one connection to the power source for normal operation. Refer to the Label Section on page 163. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The LEDs are connected to one common. All of the I/O devices used must reference the same power source. 4. Dimensions Refer to page 152.
Pinout
1 2 3 A1 A2 A3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A
18 A18 A19 A20
12 A 2 mA 1 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
19 20
L1 (+) L2 (-)
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
51
1492-IFM20D24N
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load). 2. Wiring Refer to the Label Section on page 174. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The LEDs are connected to one common. All of the I/O devices used must reference the same power source. 4. Dimensions Refer to page 152.
Pinout
2 11 B1 B2
18 20
B9 B10
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
1 3
A1 A2
2A 12 A
10
A9 A10
2 mA 1 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
19
LED Circuit
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
52
1492-IFM20D120
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. This IFM is not recommended for use with input devices or programmable controller output circuits having an off-state leakage current exceeding 0.5 mA. Use Cat. No. 1492-IFM20D120N instead, or use Cat. No. 1492-IFM20D120A-2 for input modules and Cat. No. 1492-IFM20D120-2 for output modules. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load). 2. Wiring Refer to the Label Section on page 163. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The LEDs are isolated into two groups of eight terminals. This allows each group of the I/O devices to reference a different power source. 4. Dimensions Refer to page 152.
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
Pinout
1 2 A1 A2 A3 3
10
A10
11
A11
18
19 20
L2 (-) L2 (-)
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
53
1492-IFM20D120N
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load). 2. Wiring Refer to the Label Section on page 174. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The LEDs are connected to one common. All of the I/O devices used must reference the same power source. 4. Dimensions Refer to page 152.
Pinout
2 11 B1 B2
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
18 20
B9 B10
2A 12 A
A1 A2
2.5 mA
3
1 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
10 19 A9 A10
LED Circuit
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
54
1492-IFM20D24-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load). 2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The power bus and LEDs are isolated into two groups of 10 terminals (eight LEDs). This allows each group of output devices to reference a different power source. 4. Dimensions Refer to page 153.
Pinout
1 2 3 B1 B2 B3
10
B10
11
B11
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
18 19 20
2A 12 A
A1
A11
2 mA 10 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
A2
A12
A9
A19
A10
A20
LED Circuit
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
55
1492-IFM20D24A-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load). 2. Wiring Refer to the Label Section on page 170. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The power bus comprises 20 terminals connected together. The LEDs are connected to one common. All of the I/O devices used must reference the same power source. 4. Dimensions Refer to page 153.
Pinout
1 2 3 B1 B2 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A
18 19 20
2 mA 20 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
A19 A1
A2
LED Circuit
A20
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
56
1492-IFM20D120-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load). 2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The power bus and LEDs are isolated into two groups of 10 terminals (eight LEDs). This allows each group of output devices to reference a different power source. 4. Dimensions Refer to page 153.
Pinout
1 2 3 B1 B2 B3
10
B10
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
11
B11
2A 12 A 2.5 mA
18 19 20
A1
A11
10 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
A2
A12
A9
A19
A10
A20
LED Circuit
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
57
1492-IFM20D120A-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load). 2. Wiring Refer to the Label Section on page 170. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The power bus comprises 20 terminals connected together. The LEDs are connected to one common. All of the I/O devices used must reference the same power source. 4. Dimensions Refer to page 153.
Pinout
1 2 3 B1 B2 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A 2.5 mA 20 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
18 19 20
A1
LED Circuit
A2
A19
A20
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
58
1492-IFM20D240-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load). 2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The power bus comprises 10 terminals connected together. The LEDs are connected to one common. All of the I/O devices used must reference the same power source. 4. Dimensions Refer to page 153.
Pinout
1 2 3 B1 B2 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
10 11
B10 B11
2A 12 A
18
2.5 mA 10 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
19 20
A1 A2
A11 A12
A9 A10
A19 A20
LED Circuit
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
59
1492-IFM20D240A-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load). 2. Wiring Refer to the Label Section on page 170. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The power bus comprises 20 terminals connected together. The LEDs are connected to one common. All of the I/O devices used must reference the same power source. 4. Dimensions Refer to page 153.
Pinout
1 2 3 B1 B2 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A 2.5 mA 20 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
18 19 20
LED Circuit
A19 A20
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
60
1492-IFM20D24-3
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used. 2. Wiring Refer to the Label Section on page 179. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The LEDs are connected to one common. All of the input devices used must reference the same power source. 4. Dimensions Refer to page 153.
Pinout
3 C1
18
C16
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
B1 B2 1 2 19 20 B17 B18
2A 12 A 2 mA 18 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
A1 A2
A17
LED Circuit
A18
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
61
1492-IFM20DS24-4
2. Wiring Refer to the Label Section on page 176. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation There are eight individually isolated channels. LED returns are individually isolated. 4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections. 5. Dimensions Refer to page 153.
1492-IFM20DS24-4 Specifications
Approvals
UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 1060V AC/DC 600Vp 2A 12 A
Pinout
10 B1 B2 2 (even) 8 12 (even) 18 3 (odd) 9 B14 B15 B10 B11 B6 B7 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque
4.1 mA 2 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm)
11 (odd) 17 20
A1 A2 A3 A4
0+60C
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
A17 A18 19 A19 A20
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used.
62
1492-IFM20DS120-4
2. Wiring Refer to the Label Section on page 176. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation There are eight individually isolated channels. LED returns are individually isolated. 4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections. 5. Dimensions Refer to page 153.
1492-IFM20DS120-4 Specifications
Approvals
UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 85132V AC 600Vp
Pinout
10
B1 B2
B3
B6 B7
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
B10 B11
2A 12 A 2.6 mA
B14 B15
(odd)
2 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
17 20
A1 A2 A3 A4
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
A17 A18
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
19
A19 A20
63
1492-IFM20F-F-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. 2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Twenty fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The power bus and fuse clips are isolated into two groups of 10 terminals (eight fuse clips). This allows each group of output devices to reference a different power source. 5. Dimensions Refer to page 153.
Pinout
1 2 3 B1 B2 B3
18 19 20
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A 10 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
A1 A2
A11 A12
A9 A10
A19 A20
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
64
1492-IFM20F-F24-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used. 2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Twenty fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of output devices to reference a different power source. 5. Dimensions Refer to page 153.
Pinout
1 2 3 B1 B2 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A 2 mA 10 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
18 19 20 A1 A2 A11 A12
A9 A10
A19 A20
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
65
1492-IFM20F-F24A-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. 2. Wiring Refer to the Label Section on page 181. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Twenty fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of input or output devices to reference a different power source. 5. Dimensions Refer to page 153.
Pinout
1 2 3 B1 B2 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
18 19 20
2A
A1
12 A 2 mA 10 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
A2
A3
A10
A11
A18
A19 A20
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
66
1492-IFM20F-F120-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load). 2. Wiring Refer to the Label Section on page 166. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Twenty fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of output devices to reference a different power source. 5. Dimensions Refer to page 153.
Pinout
1 2 3 B1 B2 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
18 19 20 A1 A11 A12
2A 12 A 2.5 mA 10 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
A2
A9 A10
A19 A20
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
67
1492-IFM20F-F120A-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. 2. Wiring Refer to the Label Section on page 181. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Twenty fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of input devices to reference a different power source. 5. Dimensions Refer to page 153.
Pinout
1 2 3 B1 B2 B3
18 19 20
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
A1 A2
2A 12 A 1.2 mA #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
Blown Fuse Indicator Circuit
A3
A10
A11
A18
A19 A20
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
68
1492-IFM20F-F240-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. 2. Wiring Refer to the Label Section on page 169. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Sixteen fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into two groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of input devices to reference a different power source. 5. Dimensions Refer to page 154.
Pinout
1 2 3 B1 B2 B3
18 19 20
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A
A1 A11 A12
12 A 1.2 mA
A2
A9
A19 A20
10 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
A10
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
69
1492-IFM20F-FS-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. 2. Wiring Refer to the Label Section on page 177. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The fuse clips are isolated into eight groups of terminals. This allows each group of output devices to reference a different power source. 5. Dimensions Refer to page 154.
Pinout
10 3 5 (odd) 15 17 20 B8 B9 B10 B1 B2 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A
1 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10
12 A 1 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
2 4 6 8 12 14 16 18 19
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
70
1492-IFM20F-FS24-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load). 2. Wiring Refer to the Label Section on page 177. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The fuse clips and blown fuse indicators are isolated into eight groups of terminals. This allows each group of output devices to reference a different power source. 5. Dimensions Refer to page 154.
Pinout
10 3 5 (odd) 15 17 20 B8 B9 B10 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 B1 B2 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A 2 mA #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
1 2 4 6 8 12 14 16 18 19
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
71
1492-IFM20F-FS24A-4
2. Wiring Refer to the Label Section on page 178. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The fuse clips and blown fuse indicators are isolated into two groups of terminals. This allows each group of output devices to reference a different power source. 5. Dimensions Refer to page 154.
Pinout
3 B6 B7 B8 B9 B10 B11 B12 B13
1492-IFM20F-FS24A-4 Specifications
Approvals
UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 1030V AC/DC 600Vp 2A 12 A
4 5 6 15 16 17 18
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
B14
A6 A7 A8 A9
2 mA #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
72
1492-IFM20F-FS120-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load). 2. Wiring Refer to the Label Section on page 177. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The fuse clips and blown fuse indicators are isolated into eight groups of terminals. This allows each output device to reference a different power source. 5. Dimensions Refer to page 154.
Pinout
10 3 5 (odd) 15 17 20 1 B8 B9 B10 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 B1 B2 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A 2.5 mA 1 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
2 4 6 8 12 14 16 18 19
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
73
1492-IFM20F-FS120-4
4. Isolation The fuse clips and blown fuse indicators are isolated into eight groups of terminals. This allows each output device to reference a different power source. 5. Dimensions Refer to page 153.
Pinout
2 3 A3 1 B3 4 A12 B12 A4 B4 6 7 A5 B5 8 9 A6 B6 12 11 A7 19 B7 14 13 A8 B8 16 15 A17 B17 A9 B9 A16 B16 A15 B15 A14 B14 A13 B13 A11 B11
1492-IFM20F-FS120-4 Specifications
Approvals (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 85132V AC/DC 600Vp 2A 12 A 2.5 mA 2 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
UL Component Recognized
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel: AWG #22 #20 #18 #16 #14 #12 No. of Wires 3 3 3 2 1 1
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load). 2. Wiring Refer to the Label Section on page 169. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included.
18 17
74
1492-IFM20F-FS120A-4
2. Wiring Refer to the Label Section on page 178. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The fuse clips and blown fuse indicators are isolated into two groups of terminals. This allows each group of output devices to reference a different power source. 5. Dimensions Refer to page 154.
Pinout
1492-IFM20F-FS120A-4 Specifications
Approvals
UL Component Recognized
3 4 5 6 15 16 17 18 B6 B7 B8 B9 B10 B11 B12 B13
(File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range 85132V AC/DC 600Vp 2A 12 A 2.5 mA #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
B14
A6 A7 A8 A9
A10 A11
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel: AWG #22 #20 #18 #16 #14 #12 No. of Wires 3 3 3 2 1 1
19
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
75
1492-IFM20F-FS240-4
2. Wiring Refer to the Label Section on page 169. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Ten fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The fuse clips and blown fuse indicators are isolated into eight groups of terminals. This allows each output device to reference a different power source. 5. Dimensions Refer to page 153.
Pinout
2 3 A3 A11 B11 B3 4 A12 B12 A4 B4 6 7 A5 B5 8 9 A6 B6 12 11 A15 B15 A7 19 B7 14 13 A8 B8 A16 B16 A14 B14 A13 B13 1
1492-IFM20F-FS240-4 Specifications
Approvals UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 204264V AC 600Vp 2A 12 A 2.5 mA 2 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel: AWG #22 #20 #18 #16 #14 #12 No. of Wires 3 3 3 2 1 1
16 15 A9 B9 18 17 A10
A17 B17
A18 B18
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
B10
76
1492-IFM40F
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. 2. Wiring Refer to the Label Section on page 165. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Dimensions Refer to page 154.
Pinout
1 3 5 A1 A2 A3 (odd)
2 4 6 (even) 36 38 40
B1 B2 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
77
1492-IFM40F-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. 2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The power bus is isolated into four groups of 10 terminals. This allows each group of the I/O devices to reference a different power source. 4. Dimensions Refer to page 155.
Pinout
1492-IFM40F-2 Specifications Approvals
UL Component Recognized (File E113724 Guide NRAQ2) CSA Certified (File LR1234 Class 321107) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 0132V AC/DC 600Vp
1 3 5 (odd) 35 37 39 B18 B19 B20 B1 B2 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2 4 6 (even) 36
2A 12 A 10
38 40
A1
A11
A21
A31
#22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
A2
A12
A22
A32
A9
A19
A29
A39
A10
A20
A30
A40
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
78
1492-IFM40F-3
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. 2. Wiring Refer to the Label Section on page 179. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The power busses are isolated into two groups of 18 terminals. This allows the input devices connected to the left field-side terminal block to reference a different power source than the input devices connected to the right field-side terminal block. 4. Dimensions Refer to page 155.
TB2
TB1
Pinout
TB1
5 (odd) 35 C16 B1 B2 C1
1 3 37 39
B17 B18 A1 A2
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A
6
A17 A18
TB2
C1 (even) 36 C16 B1 B2
18 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
2 4 38 40
B17 B18 A1 A2
A17 A18
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
79
1492-IFM40D24
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load). 2. Wiring The LEDs are powered off the two-position terminal block. Make only one connection to the power source for normal operation. Refer to the Label Section on page 165. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The LEDs are connected to one common. All of the I/O devices used must reference the same power source. 4. Dimensions Refer to page 154.
Pinout
1 3 5 (odd) 35 37 39 A18 A19 A20 A1 A2 A3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
L1 (+) L2 (-)
B1 B2 B3
4 6 (even) 36 38 40
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
80
1492-IFM40D24-2
2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The power bus and LEDs are isolated into four groups of 10 terminals (eight LEDs). This allows each group of output devices to reference a different power source. 4. Dimensions Refer to page 155.
Pinout
1 3 5 (odd) 19 B1 B2 B3
1492-IFM40D24-2 Specifications
Approvals
UL Component Recognized CSA Certified (File LR1234 CE Approved Factory Mutual Listed
B10 B11
21 (odd) 35 37 39
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
(File J.I. 3000590) FM approved 1030V AC/DC 600Vp 2A 12 A 2 mA 10 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
2 4 6 (even) 20 22 (even) 36 38 40
A1 A2
A11 A12
A9 A10
B30 B31
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
A21
A31 A32
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
LED Circuit
A22
A29 A30
A39 A40
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
81
1492-IFM40D24A-2
2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The power bus and LEDs are isolated into four groups of 10 terminals (eight LEDs). This allows each group of input devices to reference a different power source. 4. Dimensions Refer to page 155.
Pinout
1 3 5 (odd) 19 B10 B11 B1 B2 B3
1492-IFM40D24A-2 Specifications
Approvals UL Component Recognized (File E113724 Guide NRAQ2) CSA Certified (File LR1234 Class 321107) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 1030V AC/DC 600Vp 2A 12 A 2 mA 10 #22#12 AWG (0.24 m2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
B30 B31
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel: AWG #22 #20 #18 #16 #14 #12 No. of Wires 3 3 3 2 1 1
38 40
LED Circuit
A22
A29
A39 A40
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
A30
82
1492-IFM40D120-2
2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The power bus and LEDs are isolated into four groups of 10 terminals (eight LEDs). This allows each group of output devices to reference a different power source. 4. Dimensions Refer to page 155.
Pinout
1 3 5 (odd) 19 21 (odd) B10 B11 B1 B2 B3
1492-IFM40D120-2 Specifications
Approvals
UL Component Recognized CSA Certified (File LR1234 CE Approved Factory Mutual Listed
35 37 39
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
(File J.I. 3000590) FM approved 85132V AC 600Vp 2A 12 A 2.5 mA 10 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
B30 B31
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
A21 A22
A31 A32
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
LED Circuit
A29 A30
A39 A40
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
83
1492-IFM40D120A-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load). 2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The power bus and LEDs are isolated into four groups of 10 terminals (eight LEDs). This allows each group of input devices to reference a different power source. 4. Dimensions Refer to page 155.
Pinout
1 3 5 (odd) 19 21 (odd) 35 37 39 A1 A2 A11 A12 B18 B19 B20 B10 B11 B1 B2 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A
2
A9 A10
2.5 mA 10 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
B30 B31
LED Circuit
A29 A30
A39 A40
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
84
1492-IFM40D24-3
TB2
2. Wiring Refer to the Label Section on page 179. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation The power busses and LEDs are isolated into two groups of 18 terminals (16 LEDs). This allows the input devices connected to the left field-side terminal block to reference a different power source than the input devices connected to the right field-side terminal block. 4. Dimensions Refer to page 155.
TB1
Pinout
TB1
5 (odd) 35 C16 C1
1492-IFM40D24-3 Specifications
Approvals UL Component Recognized (File E113724 Guide NRAQ2) CSA Certified (File LR1234 Class 321107) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 1030V AC/DC 600Vp 2A 12 A 2 mA 18 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
6 (even) 36 C16 1 3 37 39 B17 B18 A1 A2 B1 B2
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
A17 A18
TB2
C1
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel: AWG #22 #20 #18 #16 #14 #12 No. of Wires 3 3 3 2 1 1
2 4 38 40
B1 B2
B17 B18 A1 A2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
LED Circuit
A17 A18
85
1492-IFM40DS24-4
2. Wiring Refer to the Label Section on page 182. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation There are 16 individually isolated channels. LED returns are individually isolated. 4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections. 5. Dimensions Refer to page 156.
Pinout
5 (odd) B1
1492-IFM40DS24-4 Specifications
Approvals
UL Component Recognized UL Recognized per Canadian
B8 B25
Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved Voltage Rating 1060V AC/DC Maximum Peak Voltage 600Vp Maximum Current (per Circuit) 2A Maximum Current (per Module) 12 A Indicator Circuit Current 4.1 mA No. of Terminals per Device Common 2 Wire Range (Rated Cross Section) #22#12 AWG (0.24 mm2) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
B32 B9
B16 B17
B24
A1 A2
A15
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
A31 A32
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
86
1492-IFM40DS24A-4
2. Wiring Refer to the Label Section on page 182. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation There are 16 individually isolated channels. LED returns are individually isolated. 4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections. 5. Dimensions Refer to page 156.
Pinout
6 (even) B9
1492-IFM40DS24A-4 Specifications
Approvals
UL Component Recognized UL Recognized per Canadian
20
B16
Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved Voltage Rating 1030V AC/DC Maximum Peak Voltage 600Vp Maximum Current (per Circuit) 2A Maximum Current (per Module) 12 A Indicator Circuit Current 4.1 mA No. of Terminals per Device Common 2 Wire Range (Rated Cross Section) #22#12 AWG (0.24 mm2) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
5 (odd) 19 22 (even) 36
B1
B8 B17
B24
21 (odd)
B25
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
35
B32 A1 A2
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
A31
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
Publication 1492-TD008A-EN-P - March 2001
A32
87
1492-IFM40DS120-4
2. Wiring Refer to the Label Section on page 182. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation There are 16 individually isolated channels. LED returns are individually isolated. 4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections. 5. Dimensions Refer to page 156.
Pinout
5 (odd) B1
1492-IFM40DS120-4 Specifications
Approvals UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 85132V AC 600Vp 2A 12 A 2.6 mA 2 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
B8 B25
B32 B9
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
B16 B17
B24
A1 A2
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel: AWG #22 #20 #18 #16 #14 #12 No. of Wires 3 3 3 2 1 1
A31
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
A32
88
1492-IFM40DS120A-4
2. Wiring Refer to the Label Section on page 182. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation There are 16 individually isolated channels. LED returns are individually isolated. 4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections. 5. Dimensions Refer to page 156.
Pinout
6 (even) B9
1492-IFM40DS120A-4 Specifications
Approvals
UL Component Recognized UL Recognized per Canadian
20
B16
Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved Voltage Rating 85132V AC 600Vp Maximum Peak Voltage Maximum Current (per Circuit) 2A Maximum Current (per Module) 12 A Indicator Circuit Current 2.6 mA No. of Terminals per Device Common 2 Wire Range (Rated Cross Section) #22#12 AWG (0.24 mm2) Wire Strip Length 0.32 in. (8 mm) Recommended Tightening Torque 3.54.5 lb-in. (0.380.50 Nm) Operating Temperature Range 0+60C
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
5 (odd) 19 22 (even) 36
B1
B8 B17
B24
21 (odd) 35
B25
B32 A1 A2
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
A31 A32
89
1492-IFM40DS240A-4
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load). 2. Wiring Refer to the Label Section on page 182. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Isolation There are 16 individually isolated channels. LED returns are individually isolated. 4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections. 5. Dimensions Refer to page 156.
1492-IFM40DS240A-4 Specifications
Approvals
UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 204264V AC 600Vp
Pinout
6 (even) 36 B32 B17
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A 2.6 mA 1 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
5 (odd) 35
A17
A32
A1 B1
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
A16 B16
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
90
1492-IFM40F-F-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. 2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing 40 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The power bus and fuse clips are isolated into four groups of 10 terminals (eight fuse clips). This allows each group of output devices to reference a different power source. 5. Dimensions Refer to page 157.
Pinout
1 3 5 (odd) 35 37 39 B18 B19 B20 B1 B2 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A
2 4 6 (even)
10 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
36 38 40
A1 A2
A11 A12
A21 A22
A31 A32
A9 A10
A19 A20
A29 A30
A39 A40
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
91
1492-IFM40F-F24-2
2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing 40 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into four groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of output devices to reference a different power source. 5. Dimensions Refer to page 157.
Pinout
1 B1 B2 B3
1492-IFM40F-F24-2 Specifications
Approvals (File E113724 Guide NRAQ2) CSA Certified (File LR1234 Class 321107) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 1030V AC/DC 600Vp 2A 12 A 2 mA 10 #22#12 AWG (0.24 mm ) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
2
UL Component Recognized
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
A9 A10
A19 A20
A29 A30
A39 A40
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
Publication 1492-TD008A-EN-P - March 2001
92
1492-IFM40F-F120-2
2. Wiring Refer to the Label Section on page 172. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing 40 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The power bus, fuse clips, and blown fuse indicators are isolated into four groups of 10 terminals (eight fuse clips and blown fuse indicators). This allows each group of output devices to reference a different power source. 5. Dimensions Refer to page 157.
Pinout
1 B1 B2 B3 (odd) 35 37 39 2 4 6 (even) 36 38 B38 B39 B40 A1 A11 A12 A21 A22 A31 A32 B18 B19 B20 B21 B22 B23
1492-IFM40F-F120-2 Specifications
Approvals (File E113724 Guide NRAQ2) CSA Certified (File LR1234 Class 321107) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 85132V AC 600Vp 2A 12 A 2.5 mA 10 #22#12 AWG (0.24 mm ) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
2
3 5
UL Component Recognized
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
40
A2
A9 A10
A19 A20
A29 A30
A39 A40
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., an MOV wired across an AC load).
93
1492-IFM40F-FS-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. 2. Wiring Refer to the Label Section on page 183. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The fuse clips are isolated into 16 groups of terminals. This allows each output device to reference a different power source. 5. Dimensions Refer to page 158.
Pinout
6 (even) 36 B18 B3
5 (odd) 35
A3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
A18
2A 12 A 1 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
94
1492-IFM40F-FS24-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load). 2. Wiring Refer to the Label Section on page 183. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source. 5. Dimensions Refer to page 158.
Pinout
6 (even) 36 B18 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A
5 (odd) 35
A3
A18
2 mA 1 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
95
1492-IFM40F-FS24-4
2. Wiring Refer to the Label Section on page 184. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections. 5. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source. 6. Dimensions Refer to page 157.
1492-IFM40F-FS24-4 Specifications
Approvals UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 1030V AC/DC 600Vp 2A 12 A 2 mA 2
Pinout
5 6 A18 B18
A2 B2
7 8
A19 B19
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
A3 B3
33
A32 B32
#22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
34
A16 B16
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel: AWG #22 #20 #18 #16 #14 #12 No. of Wires 3 3 3 2 1 1
35 36
A33 B33
A17 B17
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
Blown Fuse Indicator Circuit
96
1492-IFM40F-FS120-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load). 2. Wiring Refer to the Label Section on page 183. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source. 5. Dimensions Refer to page 158.
Pinout
6 (even) 36 B18 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A
5 A3 (odd) 35 A18
12 A 2.5 mA 1 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
97
1492-IFM40F-FS120-4
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load). 2. Wiring Refer to the Label Section on page 185. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections. 5. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source. 6. Dimensions Refer to page 157.
Pinout
5 6 A3 B3 7 8 A5 B5 (even) A4 B4 A2 B2
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A
(odd)
1.4 mA 2 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
A30 B30
A32 B32
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
98
1492-IFM40F-FS240-4
2. Wiring Refer to the Label Section on page 184. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections. 5. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source. 6. Dimensions Refer to page 157.
1492-IFM40F-FS240-4 Specifications
Approvals (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 204264V AC/DC 600Vp 2A 12 A 1.4 mA 2 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
UL Component Recognized
Pinout
5 6 A18 B18
A2 B2
7 8
A19 B19
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
A3 B3
33 34
A32 B32
A16 B16
35 36
A33 B33
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
A17 B17
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. When this IFM is used with a hard contact (relay) output circuit that switches an inductive load, surge suppression must be used (e.g., a 1N4004 diode reverse-wired across a DC load).
Blown Fuse Indicator Circuit
99
1492-IFM40F-FS24A-4
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM. 2. Wiring Refer to the Label Section on page 185. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections. 5. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source. 6. Dimensions Refer to page 157.
Pinout
A2 B2 5 6 A4 B4 7 8 (even) (odd) A5 B5 A3 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A 3.1 mA 1 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
33 34
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
100
1492-IFM40F-FS120A-4
2. Wiring Refer to the Label Section on page 185. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing 20 fuse holders are included with the IFM. Fuses (5 x 20 mm) are not included. 4. Extra Terminals Two field-side terminals are internally connected on the IFM for each channel, and are available for power source common connections. 5. Isolation The fuse clips and blown fuse indicators are isolated into 16 groups of terminals. This allows each output device to reference a different power source. 6. Dimensions Refer to page 157.
1492-IFM40F-FS120A-4 Specifications
Approvals
UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 85132V AC/DC 600Vp
Pinout
A2 B2 5 6 A4 B4 7 8 (even) (odd) A5 B5 A3 B3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current No. of Terminals per Device Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A 1.4 mA 1
#22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
34
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the IFM.
101
1492-XIM4024-16R
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM. 2. Wiring Refer to the Label Section on page 189. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Dimensions Refer to page 158.
Pinout
Refer to page 102.
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current No. of Indicators per Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
10 A 12 A per adjacent pair 48 A 2.0 mA 16 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
102
1492-XIM4024-16R, Continued
Pinout, Continued
CN
5
~ ~
K0
TB1
A3 A4 A5 A6 K1 A7 A8 B3 K2 B4 B5 B6 K3 B7 B8 B9 K4 B10 B11 B12 K5 B13 B14 A9 K6 A10 A11 A12 K7 A13 A14
CN
21
~ ~
K8
TB2
A3 A4 A5 A6 K9 A7 A8 B3 K10 B4 B5 B6 K11 B7 B8 B9 K12 B10 B11 B12 K13 B13 B14 A9 K14 A10 A11 A12 K15 A13 A14
~ ~
7
~ ~
23
~ ~
9
~ ~
25
~ ~
11
~ ~
27
~ ~
13
~ ~
29
~ ~
15
~ ~
31
~ ~
17
~ ~
33
~ ~
19
~ ~
35
TB2
8
CJOUT
7 8 5 9 10
37 39 38 40
B1 B2 A1 A2
TB1
2 4 1 3 A1 A2 B1 B2
3 4 6 1 2
CN
6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36
CJOUT
20 24 28 30 32 31 34 33 12 11 14 13 16 15 18 17
103
1492-XIM4024-8R
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM. 2. Wiring Refer to the Label Section on page 186. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Dimensions Refer to page 158.
Pinout
Refer to page 104.
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current No. of Indicators per Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
10 A 12 A per adjacent pair 48 A 2.0 mA 8 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
104
1492-XIM4024-8R, Continued
Pinout, Continued
CN
5
~ ~
K0
TB
A3 A4 A5 A6 K1 A7 A8 B3 K2 B4 B5 B6 K3 B7 B8 B9 K4 B10 B11 B12 K5 B13 B14 A9 K6 A10 A11 A12 K7 A13 A14
CN
21 23 25 27 29 31 33 35 6 8 10 12 14 16 18 20
CJOUT
20 24 28 30 32 31 34 33 12 11 14 13 16 15 18 17 22 26 19 21 23 25 27 29
~ ~
7
~ ~
9
~ ~
11
~ ~
13
~ ~
15
~ ~
17
~ ~
19
CJOUT
7 8 5 9 10 3 4 6 1 2
22 24 26 28 30 32 34 36
37 39 38 40 2 4 1 3
105
1492-XIM2024-8R
2. Wiring Refer to the Label Section on page 186. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Dimensions Refer to page 159.
Pinout
CN
3
~ ~
K0
TB
A3 A4 A5 A6 K1 A7 A8 B3 K2 B4 B5 B6 K3 B7 B8 B9 K4 B10 B11 B12 K5 B13 B14 A9 K6 A10 A11 A12 K7 A13 A14
~ ~
4
~ ~
5
1492-XIM2024-8R Specifications
Approvals
UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 2026V DC 600Vp
6
~ ~ ~ ~
7
~ ~
8
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current No. of Indicators per Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
~ ~
9
10 A 12 A per adjacent pair 48 A 2.0 mA 8 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
~ ~
10
20
B16 7 CJ OUT 8
19 1
B15 B1
B2 1 CJOUT 2
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
CN
11 12 13 14 15 16 17 18
CJOUT
20 24 28 30 32 31 34 33
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM.
106
1492-XIM20120-8R
Pinout
CN
3
~ ~
K0
TB
A3 A4 A5 A6 K1 A7 A8 B3 K2 B4 B5 B6 K3 B7 B8 B9 K4 B10 B11 B12 K5 B13 B14 A9 K6 A10 A11 A12 K7 A13 A14
~ ~
4
~ ~
5
~ ~
6
~ ~
7
~ ~
8
1492-XIM20120-8R Specifications
Approvals UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 96132V AC 600Vp 10 A 12 A per adjacent pair 48 A 2.0 mA 8 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
9
~ ~ ~ ~
10
20
B16 7 CJ OUT 8
Voltage Rating Maximum Peak Voltage Maximum Current (per Output Contact) Maximum Current (per Module) Indicator Circuit Current No. of Indicators per Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
19 1
B15 B1
B2 1 CJOUT 2
CN
11 12
CJOUT
20 24 28 30 32 31 34 33
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel: AWG #22 #20 #18 #16 #14 #12 No. of Wires 3 3 3 2 1 1
13 14 15 16 17
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM. 2. Wiring Refer to the Label Section on page 186. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Dimensions Refer to page 159.
18
107
1492-XIM24-8R
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM. 2. Wiring Refer to the Label Section on page 187. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. This relay expander must be used with a 24V DC relay master. 4. Dimensions Refer to page 159.
Pinout
Refer to page 108.
1492-XIM24-8R Specifications Approvals
UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 2026V DC 600Vp
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current No. of Indicators per Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
10 A 12 A per adjacent pair 48 A 2.0 mA 8 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
108
1492-XIM24-8R, Continued
Pinout, Continued
CJIN
16
~ ~
K0
TB
A1 A2 A3 A4 K1 A5 A6 B1 K2 B2 B3 B4 K3 B5 B6 B7 K4 B8 B9 B10 K5 B11 B12 A7 K6 A8 A9 A10 K7 A11 A12
30 31 32 25 26 29 24 23 22 21 20 19 18 17 15 14 13 11 10 9 7 5
CJIN
CJOUT
1 2 3 4 6 5 7 8 9 10 20 24 28 30 32 31 34 33 14 12 13 16 11 15 18 17
~ ~
12
~ ~
8
~ ~
6
~ ~
4
~ ~
3
~ ~
2
~ ~
1
27 28
109
1492-XIM120-8R
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM. 2. Wiring Refer to the Label Section on page 187. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. This relay expander must be used with a 120V AC relay master. 4. Dimensions Refer to page 159.
Pinout
Refer to page 110.
1492-XIM120-8R Specifications
Approvals
UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 96132V AC 600Vp
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current No. of Indicators per Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
10 A 12 A per adjacent pair 48 A 2.0 mA 8 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
110
1492-XIM120-8R, Continued
Pinout, Continued
CJIN
16
~ ~
K0
TB
A1 A2 A3 A4 K1 A5 A6 B1 K2 B2 B3 B4 K3 B5 B6 B7 K4 B8 B9 B10 K5 B11 B12 A7 K6 A8 A9 A10 K7 A11 A12
30 31 32 25 26 29 24 23 22 21 20 19 18 17 15 14 13 11 10 9 7 5
CJIN
CJOUT
1 2 3 4 6 5 7 8 9 10 20 24 28 30 32 31 34 33 14 12 13 16 11 15 18 17
~ ~
12
~ ~
8
~ ~
6
~ ~
4
~ ~
3
~ ~
2
~ ~
1
27 28
111
1492-XIMF-F24-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM. 2. Wiring Refer to the Label Section on page 188. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Extra Terminals Eight field-side terminals are jumpered together on the XIM. For some I/O modules, the terminals are also internally connected to module common through the prewired cable. Refer to the XIM and CABLE pinouts. 4. Dimensions Refer to page 159.
1492-XIMF-F24-2 Specifications
Approvals
UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 1030V DC 600Vp
Pinout
Refer to page 112.
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current No. of Indicators per Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 4A 2.0 mA 8 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
112
1492-XIMF-F24-2, Continued
Pinout, Continued
CJIN F8
16 B1
TB
30 31 32
CJIN
CJOUT
1 2 3 4 6
12
F9
B2
25 5 7 8 9 10 20 24 28 30 32 31 34 33
F10
B3
26 29
F11
B4
24 23
F12
B5
22 21
F13
B6
20 19
F14
B7
18 17
F15
B8
15 14 13 11 10 9 7 5 14 12 13 16 11 15 18 17
A1 A2 27 28 A3 A4 A5 A6 A7 A8
113
1492-XIMF-F120-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM. 2. Wiring Refer to the Label Section on page 188. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Extra Terminals Eight field-side terminals are jumpered together on the XIM. For some I/O modules, the terminals are also internally connected to module common through the prewired cable. Refer to the XIM and CABLE pinouts. 4. Dimensions Refer to page 159.
1492-XIMF-F120-2 Specifications
Approvals
UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 85132V AC 600Vp
Pinout
Refer to page 114.
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current No. of Indicators per Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 4A 2.0 mA 8 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
114
1492-XIMF-F120-2, Continued
Pinout, Continued
CJIN F8
16 B1
TB
30 31 32
CJIN
CJOUT
1 2 3 4 6
12
F9
B2
25 5 7 8 9 10 20 24 28 30 32 31 34 33
F10
B3
26 29
F11
B4
24 23
F12
B5
22 21
F13
B6
20 19
F14
B7
18 17
F15
B8
15 14 13 11 10 9 7 5 14 12 13 16 11 15 18 17
A1 A2 27 28 A3 A4 A5 A6 A7 A8
115
1492-XIMF-2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the XIM. 2. Wiring Refer to the Label Section on page 188. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Extra Terminals Eight field-side terminals are jumpered together on the XIM. For some I/O modules, the terminals are also internally connected to module common through the prewired cable. Refer to the XIM and CABLE pinouts. 4. Dimensions Refer to page 159.
1492-XIMF-2 Specifications
Approvals
UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 0132V AC/DC 600Vp
Pinout
Refer to page 116.
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current No. of Indicators per Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque
2A 4A 2.0 mA #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
116
1492-XIMF-2, Continued
Pinout, Continued
CJIN
16
TB
30 B1 31 32
CJIN
CJOUT
1 2 3 4 6
12
B2 25 5 7 8 9 10 20 24 28 30 32 31 34 33
B3
26 29
B4
24 23
B5
22 21
B6
20 19
B7
18 17
B8 15 A1 A2 A3 A4 A5 A6 A7 A8 14 13 11 10 9 7 5 14 12 13 16 11 15 18 17
27 28
117
Bulletin 1492 pre-wired cables are designed to minimize control wiring in a panel. Digital pre-wired cables, when used with an IFM or XIM, replace the point-to-point wiring between Allen-Bradley programmable controller I/O modules and individual terminal blocks. The digital ready-to-wire cables provide one end of the cable pre-terminated, for either an IFM (IFM-ready cable) or a programmable controller I/O module (I/O module-ready cable).
Pre-Wired Cables
Specifications
The pre-wired cables have a Bulletin 1746 Removable Terminal Block, 1756 Removable Terminal Block, 1769 Removable Terminal Block, or 1771 Wiring Arm on one end and a cable connector on the other to connect to the IFM or XIM. The broad offering of digital pre-wired cables supports over 90 different 16- and 32-point Bulletin 1746, 1756, 1769, and 1771 digital I/O modules.
118
No. of Conductors 20 20 20 20 20 20 20 20 20 40 40 40 40 40 20 40 40 20 20 20 20 20 20 40 40 20 20 20 20 20 20 20
Conductor Size #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG #22 AWG
Nominal Outer Diameter 9.0 mm (0.36") 9.0 mm (0.36") 9.0 mm (0.36") 9.0 mm (0.36") 9.0 mm (0.36") 9.0 mm (0.36") 9.0 mm (0.36") 9.0 mm (0.36") 9.0 mm (0.36") 11.7 mm (0.46") 11.7 mm (0.46") 11.7 mm (0.46") 11.7 mm (0.46") 11.7 mm (0.46") 9.0 mm (0.36") 11.7 mm (0.46") 11.7 mm (0.46") 9.0 mm (0.36") 11.7 mm (0.46") 9.0 mm (0.36") 9.0 mm (0.36") 9.0 mm (0.36") 9.0 mm (0.36") 11.7 mm (0.46") 11.7 mm (0.46") 9.0 mm (0.36") 9.0 mm (0.36") 9.0 mm (0.36") 9.0 mm (0.36") 9.0 mm (0.36") 9.0 mm (0.36") 9.0 mm (0.36")
I/O Module Connector Cat. No. 1746-RT25R Red Removable Terminal Block 1746-RT25B Blue Removable Terminal Block 1746-RT25R Red Removable Terminal Block 1746-RT25R Red Removable Terminal Block 1746-RT25C Orange Removable Terminal Block 1746-RT25B Blue Removable Terminal Block 1771-WH (16-Point/21 Terminal) Wiring Arm 1771-WHF (16-Point/21 Terminal) Fused Wiring Arm 1746-RT25R Red Removable Terminal Block 1746-N3 40-Pin Cable Connector 1771-WN (32-Point/40 Terminal) Wiring Arm 1771-WN (32-Point/40 Terminal) Wiring Arm 1771-WN (32-Point/40 Terminal) Wiring Arm 1771-WN (32-Point/40 Terminal) Wiring Arm 1746-RT25C Orange Removable Terminal Block 1771-WN (32-Point/40 Terminal) Wiring Arm 1771-WN (32-Point/40 Terminal) Wiring Arm 1746-RT25C Orange Removable Terminal Block 1771-WA (8-Point/10 Terminal) Wiring Arm 1756-TBNH Removable Terminal Block 1756-TBNH Removable Terminal Block 1756-TBNH Removable Terminal Block 1756-TBNH Removable Terminal Block 1756-TBCH Removable Terminal Block 1756-TBCH Removable Terminal Block 1769-RTBN18 Removable Terminal Block 1769-RTBN18 Removable Terminal Block 1769-RTBN10 Removable Terminal Block 1769-RTBN18 Removable Terminal Block 1769-RTBN18 Removable Terminal Block 1769-RTBN18 Removable Terminal Block 1769-RTBN18 Removable Terminal Block
Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE005A is for a 0.5 m cable for the 1746-IA16 I/O Module. Also refer to Build-to-Order Length Cables on page 44.
119
Pinouts
White/Green (22)
19 1
39
20 2 2 40
20-Conductor Cable
40-Conductor Cable
120
Pinouts, Continued
D igital/Analog Programm ab le Co ntroller W irin g Systems
Red RTB Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Red/Green (20) Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Blue/Red (19)
Blue RTB Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Red/Green (20)
1492-CABLEA
1492-CABLEB
White (2) Black (1) Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18)
Red RTB Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Red (19) Red/Green (20) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17)
White (2) Black (1) Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18)
Orange RTB Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Red (19) Red/Green (20) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17)
White (2) Black (1) Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18)
Blue RTB Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Red/Green (20) Blue/Red (19)
1492-CABLEC
1492-CABLED
1492-CABLEE
Black (1) White (2) Blue/Red (19) Red (3) Green (4) Orange (5) Blue (6) White/Black (7) Red/Black (8) Green/Black (9) Orange/Black (10) Blue/Black (11) Black/White (12) Red/White (13) Green/White (14) Blue/White (15) Black/Red (16) White/Red (17) Orange/Red (18) Red/Green (20)
A B C D
00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17
Black (1) White (2) Blue/Red (19) Red (3) Green (4) Orange (5) Blue (6) White/Black (7) Red/Black (8) Green/Black (9) Orange/Black (10) Blue/Black (11) Black/White (12) Red/White (13) Green/White (14) Blue/White (15) Black/Red (16) White/Red (17) Orange/Red (18) Red/Green (20)
Jumper White (2) Black (1) Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Blue/Red (19) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Red RTB Red (3) Orange (5) White/Black (7) Green/Black (9)
1492-CABLEF
1492-CABLEFF
1492-CABLEG
121
Pinouts, Continued
Black (1) Orange (5) Green/Black (9) Red/White (13) White/Red (17) White/Red-Blue (37) Orange/Green (21) Green/Black-White (25) White/Red-Green (29) Blue/White-Orange (33) White (2) Blue (6) Orange/Black (10) Green/White (14) Orange/Red (18) Black/White-Green (38) Black/White-Red (22) Orange/Black-White (26) Red/Black-Green (30) Black/White-Orange (34)
Orange (5) Green/Black (9) Red/White (13) White/Red (17) Black (1) Orange/Green (21) Green/Black-White (25) White/Red-Green (29) Blue/White-Orange (33) White/Red-Blue (37) Blue (6) Orange/Black (10) Green/White (14) Orange/Red (18) White (2) Black/White-Red (22) Orange/Black-White (26) Red/Black-Green (30) Black/White-Orange (34) Black/White-Green (38)
Red (3) White/Black (7) Blue/Black (11) Blue/White (15) Blue/Red (19) White/Black-Green (39) White/Black-Red (23) Blue/Black-White (27) Green/Black-Orange (31) White/Red-Orange (35) Green (4) Red/Black (8) Black/White (12) Black/Red (16) Red/Green (20) Red/White-Green (40) Red/Black-White (24) Black/Red-Green (28) Orange/Black-Green (32) Orange/White-Blue (36)
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
1492-CABLEJ
Orange (5) Green/Black (9) Red/White (13) White/Red (17) White/Red-Blue (37) Orange/Green (21) Green/Black-White (25) White/Red-Green (29) Blue/White-Orange (33) White/Black-Green (39) Blue (6) Orange/Black (10) Green/White (14) Orange/Red (18) Black/White-Green (38) Black/White-Red (22) Orange/Black-White (26) Red/Black-Green (30) Black/White-Orange (34) Red/White-Green (40)
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
1492-CABLEK
Black (1) White/Black (7) Blue/Black (11) Blue/White (15) Blue/Red (19) Red (3) White/Black-Red (23) Blue/Black-White (27) Green/Black-Orange (31) White/Red-Orange (35) White (2) Red/Black (8) Black/White (12) Black/Red (16) Red/Green (20) Green (4) Red/Black-White (24) Black/Red-Green (28) Orange/Black-Green (32) Orange/White-Blue (36)
39 40
1492-CABLE H
Black (1) White (2) Red (3) Green (4) Orange (5) Blue (6) White/Black (7) Red/Black (8) Green/Black (9) Orange/Black (10) Blue/Black (11) Black/White (12) Red/White (13) Green/White (14) Blue/White (15) Black/Red (16) White/Red (17) Orange/Red (18) Blue/Red (19) Red/Green (20) Orange/Green (21) Black/White-Red (22) White/Black-Red (23) Red/Black-White (24) Green/Black-White (25) Orange/Black-White (26) Blue/Black-White (27) Black/Red-Green (28) White/Red-Green (29) Red/Black-Green (30) Green/Black-Orange (31) Orange/Black-Green (32) Blue/White-Orange (33) Black/White-Orange (34) White/Red-Orange (35) Orange/White-Blue (36) White/Red-Blue (37) Black/White-Green (38) White/Black-Green (39) Red/White-Green (40)
1492-CABLEL
Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) NC Red/White (13) Blue/White (15) White/Red (17) Blue/Red (19) NC Orange/Green (21) White/Black-Red (23) Green/Black-White (25) Blue/Black-White (27) NC White/Red-Green (29) Green/Black-Orange (31) Blue/White-Orange (33) White/Red-Orange (35) NC
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) NC Green/White (14) Black/Red (16) Orange/Red (18) Red/Green (20) NC Black/White-Red (22) Red/Black-White (24) Orange/Black-White (26) Black/Red-Green (28) NC Red/Black-Green (30) Orange/Black-Green (32) Black/White-Orange (34) Orange/White-Blue (36) NC
1492-CABLEM
122
Pinouts, Continued
White (2) Red (3) Green (4) Orange (5) Blue (6) Blue/White (15) Black/Red (16) White/Red (17) Orange/Red (18) Blue/Red (19)
Orange (5) White/Black (7) Green/Black (9) Blue/Red (19) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17)
0 1 2 3 4 5 6 7 B
White (2) Blue/Red (19) Red (3) Green (4) Orange (5) Blue (6) Blue/White (15) Black/Red (16) White/Red (17) Orange/Red (18) White/Black (7) Blue/Black (11)
Red/Black (8) Green/Black (9) Orange/Black (10) Blue/Black (11) Black/White (12) Red/White (13) Green/White (14) Red/Green (20)
20 19
1492-CABLEN
1492-CABLET
1492-CABLEU
Red (3) White/Black (7) Blue/Black (11) Blue/White (15) Blue/Red (19) White/Black-Red (23) Blue/Black-White (27) Green/Black-Orange (31) White/Red-Orange (35) White/Black-Green (39) Green (4) Red/Black (8) Black/White (12) Black/Red (16) Red/Green (20) Red/Black-White (24) Black/Red-Green (28) Orange/Black-Green (32) Orange/White-Blue (36) Red/White-Green (40)
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
Black (1) Orange (5) Green/Black (9) Red/White (13) White/Red (17) Orange/Green (21) Green/Black-White (25) White/Red-Green (29) Blue/White-Orange (33) White/Red-Blue (37) White (2) Blue (6) Orange/Black (10) Green/White (14) Orange/Red (18) Black/White-Red (22) Orange/Black-White (26) Red/Black-Green (30) Black/White-Orange (34) Black/White-Green (38)
NC White (2) Green (4) Blue (6) Red/Black (8) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) NC
20
Black (1) Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Blue/Red (19)
19
1492-CABLER
1492-CABLEV
Red (3) Orange (5) White/Black (7) Green/Black (9) Black (1) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Blue/Red (19)
Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Red/Green (20)
20 19
1492-CABLES
Refer to footnote on page 125.
1492-CABLEW
123
Pinouts, Continued
Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Blue/Red (19) Orange/Green (21) White/Black-Red (23) Green/Black-White (25) Blue/Black-White (27) White/Red-Green (29) Green/Black-Orange (31) Blue/White-Orange (33) White/Red-Orange (35) NC NC
2 1
Red (3) Orange (5) White/Black (7) Green/Black (9) White (2) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Red/Green (20)
Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Red/Green (20) Black/White-Red (22) Red/Black-White (24) Orange/Black-White (26) Black/Red-Green (28) Red/Black-Green (30) Orange/Black-Green (32) Black/White-Orange (34) Orange/White-Blue (36) NC NC
36
35
1492-CABLEX
1492-CABLEY
White/Black (7) Blue/Black (11) Blue/White (15) Blue/Red (19) White/Black-Red (23) Blue/Black-White (27) Green/Black-Orange (31) White/Red-Orange (35) Black (1) Red/Black (8) Black/White (12) Black/Red (16) Red/Green (20) Red/Black-White (24) Black/Red-Green (28) Orange/Black-Green (32) Orange/White-Blue (36) White (2)
Orange (5) Green/Black (9) Red/White (13) White/Red (17) Orange/Green (21) Green/Black-White (25) White/Red-Green (29) Blue/White-Orange (33) White/Black-Green (39) Blue (6) Orange/Black (10) Green/White (14) Orange/Red (18) Black/White-Red (22) Orange/Black-White (26) Red/Black-Green (30) Black/White-Orange (34) Red/White-Green (40)
36
35
1492-CABLEZ
124
Pinouts, Continued
Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Black (1) White (2)
Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Blue/Red (19) Red/Green (20)
2 4 6 8 10 12 14 16 18
1 3 5 7 9 11 13 15 17
Red (3) Orange (5) White/Black (7) Green/Black (9) Black (1) White (2) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17)
2 4
1 3 5 7 9 11 13 15 17
Red (3) White/Black (7) Blue/Red (19) Red/Green (20) Blue/Black (11) Blue/White (15)
6 8 10 12 14 16 18
Orange/Black (10 Black (1) Orange (5) Green/Black (9) Red/White (13) White/Red (17)
1492-CABA69
Black (1) White(2) Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18)
1492-CABB69
1492-CABC69
1 3 5 7 9 11 13 15 17
2 4 6 8 10 12 14 16 18
Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Red (19) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17)
Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) NC
2 4 6 8 10 12 14 16 18
1 3 5 7 9 11 13 15 17
White (2) Green (4) Blue (6) Red/Black (8) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) NC
1492-CABLECR
Black (1) White (2) Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18)
1492-CABD69
Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Blue/Red (19) Red/Green (20)
2 4 6 8 10 12 14 16 18
1 3 5 7 9 11 13 15 17
Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) NC
2 4 6 8 10 12 14 16 18
1 3 5 7 9 11 13 15 17
Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) NC
Green (4) Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) NC NC Red/Green (20)
2 4 6 8 10 12 14 16 18
1 3 5 7 9 11 13 15 17
Red (3) Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) NC NC Blue/Red (19)
1492-CABE69
1492-CABF69
1492-CABG69
Orange (5) White/Black (7) Green/Black (9) Blue/Black (11) Red/White (13) Blue/White (15) White/Red (17) Blue/Red (19) Black/White-Red (22) NC White/Black-Red (23) Orange/Black-White (26) NC Blue/Black-White (27) Red/Black-Green (30) NC Green/Black-Orange (31) Black/White-Orange (34) NC White/Red-Orange (35)
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
Blue (6) Red/Black (8) Orange/Black (10) Black/White (12) Green/White (14) Black/Red (16) Orange/Red (18) Red/Green (20) NC Orange/Green (21) Red/Black-White (24) NC Green/Black-White (25) Black/Red-Green (28) NC White/Red-Green (29) Orange/Black-Green (32) NC Blue/White-Orange (33) Orange/White-Blue (36)
1492-CABR71
Refer to footnote on page 125.
125
The I/O module-ready cables have a pre-wired wiring arm or removable terminal block on one end to connect the programmable controller I/O module and 1240 individually colored #18 AWG conductors on the other. These cables provide the convenience of a pre-wired I/O module connector, while still allowing the flexibility to wire to standard terminal blocks. Pre-wired I/O module connectors include: Cat. No. 1746-N3 40-point plug-in connector (Cat. No. CABLEN3) Bulletin 1746 16-point removable terminal blocks in Red, Blue, and Orange (Cat. No. CABLE RTBR, RTBB, RTBO) Cat. No. 1756-TBCH 36-point removable terminal block (Cat. No. CABLETBCH) Cat. No. 1756-TBNH 20-point removable terminal block (Cat. No. CABLETBNH) Cat. No. 1769-RTBN10 removable terminal block (Cat. No. CABLERTN10) Cat. No. 1769-RTBN18 20-point removable terminal block (Cat. No. CABLERTN18) Cat. No. 1771-WH 16-point wiring arm (Cat. No. CABLEWH) Cat. No. 1771-WN 32-point wiring arm (Cat. No. CABLE WN) Cat. No. 1771-WHF 16-point fused wiring arm (with fuses) (Cat. No. CABLEWHF) Cat. No. 1771-WD 6-point wiring arm (Cat. No. CABLEWD) Cat. No. 1771-WA 8-point wiring arm (Cat. No. CABLEWA)
Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025WH is for a 2.5 m cable with a pre-wired 1771-WH Wiring Arm on one end. Also refer to Build-to-Order Length Cables on page 44.
126
Insulation Rating 300V 80C 300V 80C 300V 80C 300V 80C 300V 80C 300V 80C 300V 80C 300V 80C 300V 80C 300V 80C 300V 80C 300V 80C 300V 80C
Number of Conductors 40 20 20 20 40 20 20 20 12 12 20 20 40
Conductor Size #22 AWG #18 AWG #18 AWG #18 AWG #18 AWG #18 AWG #18 AWG #18 AWG #18 AWG #18 AWG #18 AWG #18 AWG #18 AWG
Nominal Outer Diameter 11.2 mm (0.44") 11.4 mm (0.45") 11.4 mm (0.45") 11.4 mm (0.45") 14.1 mm (0.55") 11.4 mm (0.45") 9.0 mm (0.36") 9.0 mm (0.36") 9.0 mm (0.36") 9.0 mm (0.36") 11.4 mm (0.45") 11.4 mm (0.45") 14.1 mm (0.55")
I/O Module Connector 1746-N3 (40-Point) Plug-in Connector 1771-RT25B Blue Removable Terminal Block 1771-RT25C Orange Removable Terminal Block 1771-RT25R Red Removable Terminal Block 1756-TBCH (36-Point) Removable Terminal Block 1771-TBNH (20-Point) Removable Terminal Block 1769-RTBN10 Removable Terminal Block 1771-RTBN18 (20-Point) Removable Terminal Block 1771-WA (8-Point/10 Terminal) Wiring Arm 1771-WD (6-Point/12 Terminal) Wiring Arm 1771-WH (16-Point/21 Terminal) Wiring Arm 1771-WHF (16-Point/21 Terminal) Fused Wiring Arm 1771-WN (32-Point/40 Terminal) Wiring Arm
Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025WH is for a 2.5 m cable with a pre-wired 1771-WH Wiring Arm on one end. Also refer to Build-to-Order Length Cables on page 44.
127
Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025WH is for a 2.5 m cable with a pre-wired 1771-WH Wiring Arm on one end. Also refer to Build-to-Order Length Cables on page 44.
128
39 40
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35
2 4 6 8 10 12 14 16 18 20
1 3 5 7 9 11 13 15 17 19
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1492-CABLEN3
1492-CABLETBCH
1492-CABLETBNH
1492-CABLEWN
1492-CABLEWH
1492-CABLEWF
1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 1 3 5 7 9 11 13 15 17 2 4 6 8 10 12 14 16 18
2 1 3 5 7 9 11 13 15 17
4 6 8 10 12 14 16 18
Red Green Blue Red/Black Orange/Black Black/White Green/White Black/Red Orange/Red Red/Green
2 4 6 8 10 12 14 16 18
1 3 5 7 9 11 13 15 17
White Black Orange White/Black Green/Black Blue/Black Red/White Blue/White White/Red Blue/Red
1492-CABLEWD 1492-CABLEWA
1492-CABRTN10
1492-CABRTN18
Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025WH is for a 2.5 m cable with a pre-wired 1771-WH Wiring Arm on one end. Also refer to Build-to-Order Length Cables on page 44.
129
IFM-ready cables have a cable connector on one end to attach to the IFM and either 20 or 40 individually colored conductors on the other end (Cat. Nos. CABLEP and CABLEQ, respectively). These cables allow the IFM to be used in specialty applications that require a custom connection.
IFM-Ready Cable Specifications Cat. No. 1492-CABLEP 1492-CABLEQ Cable Lengths 1.0, 2.5, 5.0 m 1.0, 2.5, 5.0 m Insulation Rating 300V 80C 300V 80C Number of Conductors 20 40 Conductor Size #22 AWG #22 AWG Nominal Outer Diameter 9.0 mm (0.36") 11.7 mm (0.46") Current/ Conductor 2A 2A Compatible IFM Cat. Nos. 1492-IFM20_ _ _ 1492-XIM20_ _ _ 1492-IFM40_ _ _ 1492-XIM40_ _ _
Each colored conductor is connected to one pin of the molded cable connector as listed in the tables below.
1492-CABLEP Connector Pin Number 1 2 3 4 5 6 7 8 9 10 Wire Color Base/Stripe/Stripe Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Connector Pin Number 11 12 13 14 15 16 17 18 19 20 Wire Color Base/Stripe/Stripe Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green
Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025P is for a 2.5 m, 20 conductor IFM-ready cable. Also refer to Build-to-Order Length Cables on page 44.
130
Cables are available in lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-CABLE025P is for a 2.5 m, 20 conductor IFM-ready cable. Also refer to Build-to-Order Length Cables on page 44.
131
For all AIFM dimensions, refer to page 160. For general Adhesive Label Card information, refer to page 162. For Field-Side Wiring Diagrams, refer to the Wiring System web page at http://www.ab.com/catalogs/b113. Refer to page 202 for specific platform web site information. Refer to the online documentation for new product information.
Symbols and Terminal Identification Conventions Used Throughout the Pinout Section
1492-AIFM Field-Side Terminal 1492 Pre-Wired Cable I/O Module Connection Fuse and Blown Fuse Indicator One-Pole DIP Switch Two-Pole DIP Switch 1492-AIFM and Cable Connection (D-Shell Pin) Test Point
Field-Side Terminal Identification Convention:
C1 C2 C3 C4 C5 . . .
B1 B2 B3 B4 B5 . . .
B1
B2
B3
B4
B5 . . .
A1 A2 A3 A4 A5 . . .
A1
A2
A3
A4
A5 . . .
132
1492-AIFM4-3
1492-AIFM4-3 Specifications
Approvals
UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 0132V AC/DC 600Vp
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Shield Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A
2. Wiring Refer to the Label Section on page 191. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. DIP Switches Selectable resistors are available to current limit the Cat. Nos. 1771-OFE2 and -OFE3 output circuits. By opening the switch (off or down position), 250 series impedance is inserted into the output circuit. Default switch position is on/closed/no series impedance. Do not exceed maximum loop impedance of output module (1200 for -OFE2; 450 for -OFE3). 4. Test Points With optional 250 series impedance in output circuit (refer to DIP Switches), test points can be used to measure loop voltage/current. Refer to the Pinout for test point circuit location. 5. Shield Terminals Four field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. 6. Dimensions Refer to page 160.
Pinout
2 A3 B3 A7 B7 A1
4
1
#22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
8
TP1
TP2
15 TP3 14 TP4
A2
A5
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
13 TP5 12 TP6
A6
B1
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
11 TP7 TP8
B2
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.
10
B5
9 D-Shell Housing
B6
A4 A8 B4 B8
133
1492-AIFM6S-3
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM. 2. Wiring Refer to the Label Section on page 192. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Shield Terminals Six field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. 4. Dimensions Refer to page 160.
UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 0132V AC/DC 600Vp
Pinout
13 12 25 24 11 23 22 9 21 19 B1 A1 B2 B3 A3 B4 B5 A5 B6 B7 A7 B8 B9 A9 B10 B11 A11 B12 D-Shell Housing A2 A4 A6 A8 A10 A12
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Shield Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A 6 #22#12 AWG (0.24 mm ) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
2
6 18 17 4 16 15 2 14
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
134
1492-AIFM8-3
1492-AIFM8-3 Specifications
Approvals
UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 0132V AC/DC 600Vp
2. Wiring Refer to the Label Section on page 193. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Extra Terminals Eight field-side terminals are jumpered together on the AIFM. For some I/O modules, the terminals are also internally connected to module common through the prewired cable. Refer to the AIFM and ACABLE pinouts. 4. Shield Terminals Eight field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. 5. Dimensions Refer to page 160.
Pinout
3 2 1 14 15 16 17 18 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common No. of Terminals per Shield Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A 8 8 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
12 13 25 24 23 22 20 21
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
4 6 8 10 19
#22 3
#20 3
#18 3
#16 2
#14 1
#12 1
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM.
135
1492-AIFM6TC-3
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM. 2. Wiring Refer to the Label Section on page 192. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Shield Terminals Six field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. 4. Cold Junction Compensation This AIFM contains on-board cold junction compensation through a thermistor and isothermal bar mounted to the field-side terminals. Do not install the additional cold junction sensor (provided with the Cat. No. 1756-IT6I thermocouple input module) on the removable terminal block of the pre-wired cable. 5. Dimensions Refer to page 160.
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Shield Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
Pinout
13 25 24 23 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 A7 T 20 12 11 9 A1 A3 A5 A9 A11
2A 12 A 6 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
22 21 19 18 17 16 15 14 6
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
4 2
#20 3
#18 3
#16 2
#14 1
#12 1
136
1492-AIFM4C-F-5
1492-AIFM4C-F-5 Specifications
Approvals UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 1030V DC 600Vp 2A 12 A 2 mA 4 4 #22 #12 AWG (0.2 4 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.38 0.50 Nm) 0+60C
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common No. of Terminals per Shield Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
3. Fusing Ten fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 2 A per input, 12 A per AIFM. 4. Isolation The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. All inputs must reference the same power source. 5. DIP Switches For ease of wiring, unused inputs can be jumpered to module common by closing the DIP switches (ON position). Default switch position is OPEN/OFF/NOT jumpered together. 6. Test Points When using a two-wire transmitter, test points can be used to measure input loop current. Refer to the Pinout for test point circuit location. 7. Extra Terminals Four field-side terminals are internally jumpered on the AIFM. They can be used for power source common connections. 8. Shield Terminals Four field-side terminals are jumpered together on AIFM and internally connected to the D-shell housing. 9. Dimensions Refer to page 160.
Pinout
8 B1 15 B2
14
B3
13
B4
12
B5
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel: AWG No. of Wires #22 3 #20 3 #18 3 #16 2 #14 1 #12 1
11
B6
2 10 9
B7 B8 B9 B10 B11 TP1 TP2 A1 TP3 TP4 A2 B12 A5 . . . . A8 D-Shell Housing A9 . . . . A12
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM. 2. Wiring Refer to the Label Section on page 190. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202.
137
1492-AIFM4I-F-5
1492-AIFM4I-F-5 Specifications
Approvals UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 10 30V DC 600Vp 2A 12 A 2 mA 4 4 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0 +60C
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common No. of Terminals per Shield Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
4. Isolation The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. All inputs must reference the same power source. 5. DIP Switches For ease of wiring, unused inputs can be jumpered to module common by closing the DIP switches (ON position). Default switch position is OPEN/OFF/NOT jumpered together. 6. Test Points When using a two-wire transmitter, test points can be used to measure input loop current. Refer to the Pinout for test point circuit location. 7. Extra Terminals Four field-side terminals are internally jumpered on the AIFM. They can be used for power source common connections. 8. Shield Terminals Four field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. 9. Dimensions Refer to page 160.
Pinout
8 B1 15 B2
14
B3
13
B4
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel: AWG #22 #20 #18 #16 #14 #12 No. of Wires 3 3 3 2 1 1
12
B5
11 2
B6 B7
10
B8
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM. 2. Wiring Refer to the Label Section on page 190. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Ten fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 2 A per input, 12 A per AIFM.
9 1
TP7
TP8
138
1492-AIFM8-F-5
1492-AIFM8-F-5 Specifications
Approvals UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 10 30V DC 600Vp 2A 12 A 2 mA 9 18 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0 +60C
4. Isolation The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. All inputs must reference the same power source. 5. DIP Switches For ease of wiring, unused inputs can be jumpered to module common by closing the DIP switches (ON position). Default switch position is OPEN/OFF/NOT jumpered together. 6. Extra Terminals Nine field-side terminals are internally jumpered on the AIFM. They can be used for power source common connections. 7. Shield Terminals Eighteen field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. 8. Dimensions Refer to page 161.
Pinout
3 C1 2 1 C2 C3
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common No. of Terminals per Shield Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
14 15
C4 C5
16 17
C6 C7
18 12
C8 C9
13 25
C10 C11
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel: AWG #22 #20 #18 #16 #14 #12 No. of Wires 3 3 3 2 1 1
24 23
C12 C13
22 20
C14 C15
21
C16
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM. 2. Wiring Refer to the Label Section on page 195. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Ten fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 2 A per input, 12 A per AIFM.
Publication 1492-TD008A-EN-P - March 2001
139
1492-AIFM16-F-3
1492-AIFM16-F-3 Specifications
Approvals UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 10 30V DC 600Vp 2A 12 A 2 mA 18 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
4. Isolation The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. All inputs must reference the same power source. 5. DIP Switches For ease of wiring, unused inputs can be jumpered to module common by closing the DIP switches (ON position). Default switch position is OPEN/OFF/NOT jumpered together. 6. Shield Terminals Eighteen field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. 7. Dimensions Refer to page 161.
Pinout
3 2 1 14 15 16 17 18 12 13 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B1 C1 . . . . . C16 D-Shell Housing A1 . . . . . A18
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Shield Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel: AWG #22 #20 #18 #16 #14 #12 No. of Wires 3 3 3 2 1 1
25 24 23 22
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM. 2. Wiring Refer to the Label Section on page 196. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Twenty fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 2 A per input, 12 A per AIFM.
20 21 4 6 8 10 19
140
1492-AIFM16-F-5
1492-AIFM16-F-5 Specifications
Approvals UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 10 30V DC 600Vp 2A 12 A 2 mA 16 16 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0 +60C
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common No. of Terminals per Shield Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
4. Isolation The fuse clips and blown fuse indicators are internally connected to two separate power source field-side terminals. All inputs within a group must reference the same power source. 5. DIP Switches For ease of wiring, unused inputs can be jumpered to module common by closing the DIP switches (ON position). Default switch position is OPEN/OFF/NOT jumpered together. 6. Extra Terminals Sixteen field-side terminals (C9C16 on TB1 and TB2) are internally jumpered on the AIFM and connected to module common. Eighteen field-side terminals (B10B18 on TB1 and TB2) are internally jumpered on the AIFM and can be used for power source common connections. There are two field-side terminals (A17 and A18 on TB1) that can be externally jumpered to connect the two groups of field-side terminals. 7. Shield Terminals Sixteen field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. 8. Dimensions Refer to page 161.
Pinout
3 2 1 14 15 16 17 18 C1 C2 C3 C4 C5 C6 C7 C8 C9 . . . . C16 A17 4 6 8 10 19 12 13 25 24 23 22 20 21 C1 C2 C3 C4 C5 C6 C7 C8 C9 . . . . C16
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel: AWG #22 #20 #18 #16 #14 #12 No. of Wires 3 3 3 2 1 1
B1 B2 . . . . . B9 B10 . . . B18
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM. 2. Wiring Refer to the Label Section on page 197. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Twenty fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 2 A per input, 12 A per AIFM.
Publication 1492-TD008A-EN-P - March 2001
D-Shell Housing
A1 . . . A8
A1 . . . A8
141
1492-AIFMQS
1492-AIFMQS Specifications
Approvals UL Component Recognized (File E113724 Guide NRAQ2) UL Recognized per Canadian Safety Standards (cUR) (File E113724 Guide NRAQ2) CE Approved Factory Mutual Listed (File J.I. 3000590) FM approved 10 30V DC 600Vp 3A 12 A 2 mA 8 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0 +60C
4. Isolation The fuse clips and blown fuse indicators are internally connected to two separate power source field-side terminals. All inputs within a group must reference the same power source. 5. Extra Terminals Four field-side terminals (on TB1) are internally jumpered on the AIFM and connected to module common. Four field-side terminals (on TB1) are internally jumpered on the AIFM and can be used for power source common connections. 6. Shield Terminals Eight field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. 7. Dimensions Refer to page 161.
Pinout
+INT 1 -INT 1 +RET 1 -RET 1 +OUT 1 OUT COM +INT 2 -INT 2 +RET 2 -RET 2 +OUT 2 OUT COM +INT 3 -INT 3 +RET 3 -RET 3 +OUT 3 OUT COM +INT 4 -INT 4 +RET 4 -RET 4 +OUT 4 OUT COM
6 18 20 19 5 17 3 15 4 16 2 Black/Blue Blue/Black Black/Orange Red/Gray Gray/Red Red/Brown Brown/Red Red/Green Green/Red Red/Orange Orange/Red 4 5 15 6 9 8 22 14 23 24 18 12 24 13 25 11 23 9 21 10 22 8 Red/Blue White/Gray Gray/White White/Brown Brown/White White/Green Green/White White/Orange Orange/White White/Blue Blue/White 1 11 2 3 17 26 10 19 20 12 25
+ Interrogate 1 - Interrogate 1 + Return 1 - Return 1 Drive Output 1 Drive Common + Interrogate 2 - Interrogate 2 + Return 2 - Return 2 Drive Output 2
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Shield Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
+ Interrogate 3 - Interrogate 3 + Return 3 - Return 3 Drive Output 3 Drive Common + Interrogate 4 - Interrogate 4 + Return 4 - Return 4 Drive Output 4
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel: AWG #22 #20 #18 #16 #14 #12 No. of Wires 3 3 3 2 1 1
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM. 2. Wiring Refer to the Label Section on page 198. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Twenty fuse holders are included with the AIFM. Fuses (5 x 20 mm) are not included. Do not exceed 3 A per input, 12 A per AIFM.
COM LDT COM LDT COM GND SH SH -V -V1F -V4F +V +V1F +V4F DRAIN
7 1 Orange/Black Blue/Red 21 13
142
1492-AIFMPI
Application Notes
1. Compatibility To ensure proper operation with the I/O module, do not exceed the voltage and current ratings of the AIFM. 2. Wiring Refer to the Label Section on page 199. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 202. 3. Fusing Two fuse holders for the outputs are included with the AIFM. Eight fuses (0.25 A, 5 x 20 mm) are included with the fused supply inputs. Do not exceed 2 A per output. 4. Isolation The fuse clips and blown fuse indicators are internally connected to one power source field-side terminal. All inputs must reference the same power source. 5. Jumpers J0J7 provide the option of connecting the negative inputs to the return. J8 commons the shield to the return. Default switch position is OPEN/OFF/NOT jumpered together. 6. Shield Terminals Eight field-side terminals are jumpered together on the AIFM and internally connected to the D-shell housing. 7. Dimensions Refer to page 161.
Voltage Rating Maximum Peak Voltage Maximum Current (per Circuit) Maximum Current (per Module) Indicator Circuit Current (Nominal) No. of Terminals per Device Common No. of Terminals per Shield Common Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
2A 12 A 2 mA 1 8 #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C
Pinout
Refer to page 143.
For transients >600Vp, use a UL recognized suppression device rated at 2.5 kV withstand. Maximum number of the same gauge stranded copper conductors allowed per wire funnel:
#20 3
#18 3
#16 2
#14 1
#12 1
143
1492-AIFMPI, Continued
Pinout, Continued
CN
1 2 3
TB
+
J0
TB
B9 V0 +24
CHANNEL 0
+
F0
B2
F1
B4
1 2 3
J7
CHANNEL 7
B1
F2
B6
9 22 SHELL
1 2 3
J8
F3
B8 +V FUSED 0-7
F4
B11
F5
B13
F6
B15
F7
B17 12 24
CHANNEL 0 1 2 3 4 5 6 7
4 14 3 15 2 16 1 17 8 18 7 19 6 20 5 21 A1 +0 A2 0 A3 +1 A4 1 A5 +2 A6 2 A7 +3 A8 3 A10 +4 A11 4
IN IN
B18
F8
25 B19
IN 13 IN IN
F9
B20
144
Bulletin 1492 pre-wired cables are designed to minimize control wiring in a panel. Analog pre-wired cables, when used with an AIFM, replace the pointto-point wiring between Allen-Bradley programmable controller I/O modules and individual terminal blocks. The analog ready-to-wire cables provide one end of the cable pre-terminated for an AIFM (AIFM-ready cable).
D igital/Analog Programm ab le Co ntroller W irin g Systems
Pre-Wired Cables
Specifications
The pre-wired cables have a Bulletin 1746 Removable Terminal Block, Bulletin 1756 Removable Terminal Block, Bulletin 1769 Removable Terminal Block, or Bulletin 1771 Wiring Arm on one end and a D-shell on the other to connect to the AIFM. All analog cables have an overall shield and most have #22 AWG twisted pairs for additional noise immunity. In addition, most analog cables have prepared ring lugs on the drain wire for convenient grounding of the cable shield to the programmable controller chassis. The broad offering of analog pre-wired cables supports over 26 different Bulletin 1746, 1756, 1769, and 1771 analog, RTD, and thermocouple I/O modules.
145
I/O Module Connector 1746-RT28 12-Position Removable Terminal Block 1746-RT26 2-Position and 1746-RT27 8-Position Removable Terminal Block 1746-RT25G Green Removable Terminal Block 1746-RT25G Green Removable Terminal Block 1771-WG (21 terminal) 1771-WG (21 terminal) Wiring Arm 1771-WC (10 terminal) Wiring Arm 1771-WF (18 terminal) Wiring Arm 1771-WF (18 terminal) Wiring Arm 1746-RT28 12-Position Removable Terminal Block 1757-PIM 36-Position Removable Terminal Block 1746-QS (26 terminal D-shell) 1756-TBNH 20-Position Removable Terminal Block 1756-TBNH 20-Position Removable Terminal Block 1756-TBNH 20-Position Removable Terminal Block 1746-RT25G Green Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBCH 36-Position Removable Terminal Block 1756-TBNH 20-Position Removable Terminal Block 1756-TBNH 20-Position Removable Terminal Block 1756-TBNH 20-Position Removable Terminal Block 1756-TBNH 20-Position Removable Terminal Block 1769-RTBN10 20-Position Removable Terminal Block 1769-RTBN10 20-Position Removable Terminal Block 1769-RTBN18 20-Position Removable Terminal Block 1769-RTBN18 20-Position Removable Terminal Block 1769-RTBN18 20-Position Removable Terminal Block 1769-RTBN18 20-Position Removable Terminal Block
AIFM Connector 15-pin D-shell 15-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 15-pin D-shell 25-pin D-shell 25-pin D-shell 15-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 25-pin D-shell 15-pin D-shell 15-pin D-shell 25-pin D-shell 25-pin D-shell 15-pin D-shell 15-pin D-shell 15-pin D-shell 15-pin D-shell 15-pin D-shell 15-pin D-shell
No. of Conductors 5 Twisted Pairs 5 Twisted Pairs 9 Twisted Pairs 20 Conductors 9 Twisted Pairs 20 Conductors 5 Twisted Pairs 9 Twisted Pairs 20 Conductors 5 Twisted Pairs 11 Twisted Pairs 12 Twisted Pairs 9 Twisted Pairs 9 Twisted Pairs 20 Conductors 20 Conductors 20 Conductors 20 Conductors 5 Twisted Pairs 5 Twisted Pairs 20 Conductors 20 Conductors 9 Twisted Pairs 9 Twisted Pairs 20 Conductors 20 Conductors 9 Twisted Pairs 9 Twisted Pairs 5 Twisted Pairs 5 Twisted Pairs 5 Twisted Pairs 5 Twisted Pairs 5 Twisted Pairs 5 Twisted Pairs
Insulation Rating 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C 300V 80 C
Conductor Size 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG 22 AWG
Nominal Outer Diameter 7.44 mm (0.293") 7.44 mm (0.293") 6.78 mm (0.267") 8.43 mm (0.332") 6.78 mm (0.267") 8.43 mm (0.332") 7.44 mm (0.293") 6.78 mm (0.267") 8.43 mm (0.332") 7.44 mm (0.293") 11.5 mm (0.45") 10.2 mm (0.40") 6.78 mm (0.267") 6.78 mm (0.267") 8.43 mm (0.332") 10.2 mm (0.40") 8.43 mm (0.332") 8.43 mm (0.332") 8.43 mm (0.332") 8.43 mm (0.332") 8.43 mm (0.332") 8.43 mm (0.332") 6.78 mm (0.267") 6.78 mm (0.267") 8.43 mm (0.332") 8.43 mm (0.332") 6.78 mm (0.267") 6.78 mm (0.267") 7.44 mm (0.293") 7.44 mm (0.293") 7.44 mm (0.293") 7.44 mm (0.293") 7.44 mm (0.293") 7.44 mm (0.293")
Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m and 5.0 m. To order, insert the desired cable length code into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-ACABLE005A is for a 0.5 m cable for the 1746-NI4 I/O Module. Also refer to Build-to-Order Length Cables on page 44. All pre-wired analog cables have an overall shield. On 1492-ACABLEC and 1492-ACABLE D, the drain wire is connected to the shield terminal on the I/O module connector. All other 1492-ACABLEs have a ring lug on the 7.87" (200 mm) exposed drain wire at the I/O module end of the cable. Not every connection is always used.
146
Pinouts
Analog Pre-Wired Cables
The following diagrams indicate how the analog pre-wired cables are connected on both ends. The description listed first is the wire color of the conductor connected to the screw terminal on the respective Wiring Arm or Removable Terminal Block. The number that follows in parentheses is the corresponding pin number in the D-shell connector on the other end.
Shield Base Color Stripe Color
White/Green (22)
15
25
1 1
14
13
147
Pinouts, Continued
NC Red (3) Black (2) White (1) Black (14) Green (15) Black (16) Blue (17) Black (18) Yellow (12) Black (13) Brown (25) Black (24) Orange (23) Black (22) Red (20) White (21) Drain
0 1
0 1 2
Red (8) Black (15) White (14) Black (13) Green (12) Black (11) Blue (10) Black (9)
3 4 5
6 7
1492-ACABLE___A
1492-ACABLE___B
1492-ACABLE___C
1 2 3 4 5 6 NC
1 2 3 4 5
Red (3) Brown (2) Black (1) White (14) Orange (4) White/Black (15) White/Brown (16) White/Red (17) White/Orange (18) Blue (10) Violet (12) Gray (13) White/Black/Brown (25) White/Gray (24) Green (8) White/Violet (23) White/Blue (22) White/Yellow (20) White/Green (21) Yellow (6) NC
Green (15) Black (16) Blue (17) Black (18) NC Yellow (12) Black (13) Brown (25) Black (24) NC Orange (23) Black (22) Red (20) White (21) Red (6) Green (19)
6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
NC NC Blue (13) White/Blue (24) White/Violet (25) White/Green (23) Green (12) Yellow (11) NC NC White/Yellow (22) White/Red (19) White/Orange (21) White/Brown (18) Orange (9) Red (6) NC Drain
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
1492-ACABLE___D
1492-ACABLE___E
1492-ACABLE___F
148
Pinouts, Continued
18 16 14
Red (8) Black (15) White (14) Black (13) Green (12) Black (11) Blue (10) Black (9) NC NC
A 0 1
12 10 8 NC NC
Red (3) Black (2) White (1) Black (14) Green (15) Black (16) Blue (17) Black (18)
18 16 14 12 10
2 3 4 5 6 7 B
6 4 2
Yellow (12) Black (13) Brown (25) Black (24) Orange (23) Black (22) Red (20) White (21)
8 6 4 2
White/Violet (25) Green (12) Blue (13) White/Green (23) Yellow (11) White/Blue (24) White/Orange (21) Orange (9) White/Yellow (22) White/Brown (18) Red (6) White/Red (19) White (16) Brown (4) White/Black (17) Violet (14) Black (2) Gray (15)
0 1 2 3 4 5 6 7 8 9 10 11 NC NC NC NC
1492-ACABLE___G 1492-ACABLE___H
1492-ACABLE___J
1492-ACABLE___L
(1) Blue (17) Black (7) Brown (19) Black (5) Red (21) White (24) Red (13) Blue
36 35
Red/Brown (5) Brown/Red (17) Red/Green (20) Green/Red (19) Orange/Red (18) Red/Orange (6) Orange/White (25) White/Orange (13) Blue/White (24) White/Blue (12)
1
18 26
NC NC
1492-ACABLE___M
1492-ACABLE___Q
149
Pinouts, Continued
Red (3) Black (1) White/Black (15) White/Red (17) Orange (4) Yellow (6) Violet (12) White/Black/Brown (25) White/Violet (23) White/Yellow (20)
2 4 6 8 1 3 5 7
10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 20 29 32 31 34 33 36 35
Brown (2) White (14) White/Brown (16) White/Orange (18) Gray (13) White/Gray (24) White/Blue (22) White/Green (21)
10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35
1492-ACABLE___TA
Red (3) Black (2) White (1) Black(14) Green (15) Black (16) Blue (17) Black (18)
2 4 6 8 1 3 5 7
1492-ACABLE___TB
Red (3) Black (2) White (1) Black(14) Green (15) Black (16) Blue (17) Black (18)
2 4 6 8
1 3 5 7
10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35
10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35
Red (3) Brown (2) Black (1) White (14) Orange (4) White/Black (15) White/Brown (16) White/Red (17) White/Yellow (18) Violet (12) Gray (13) White/Black/Brown (25) White/Gray (24) Blue (10) White/Violet (23) White/Blue (22) White/Yellow (20) White/Green (21)
2 4 6 8
1 3 5 7
10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35
Yellow (6)
Green (8)
1492-ACABLE___TC
Red (3) Brown (2) Black (1) White(14)
2 4 6 8 1 3 5 7
1492-ACABLE___TD
Red (3) Black (2) White (1) Black(14) Green (15) Black (16) Blue (17) Black (18) Yellow (12) Black (13) Brown(25) Black (24) Orange (23) Black (22) Red (20) White (21)
2 4 6 8 1 3 5 7
1492-ACABLE___UA
Red (3) Black (2) White (1) Black(14) Green (15) Black (16) Blue (17) Black (18) Yellow (12) Black (13) Brown(25) Black (24) Orange (23) Black (22) Red (20) White (21)
2 4 6 8 1 3 5 7
J1 J2 J3 J4 J5 J6
Orange (4) Yellow (6) White/Black (15) White/Brown (16) White/Red (17) White/Orange (18) Violet (12) Gray (13) White/Black/Brown (25) White/Gray (24) Green (8) Blue (10) White/Violet (23) White/Blue (22) White/Yellow (20) White/Green (21)
10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35
10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35
10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 34 33 36 35
J7 J8
1492-ACABLE___UB
1492-ACABLE___UC
150
Pinouts, Continued
1 3 5 7
4 6 8
10 9 12 11 14 13 16 15 18 17 20 19
10 9 12 11
14 13 16 15 18 17 20 19
1492-ACABLE___VA
1492-ACABLE___VB
1 3 5 7
1 3 5 7
4 6 8
4 6
NC
10 9 12 11
10 9 12 11 14 13 16 15
14 13 16 15 18 17 20 19
18 17 20 19
Green (15) Black (16) Black (18) Blue (17) Red (6) Green (19)
1492-ACABLE___WA
1492-ACABLE___WB
Blue (24)
2 4
1 3 5 7
Red (13)
Blue (24) NC
2 4 6 8
1 3 5 7
Red (13) NC Black (25) White (22) NC Black (21) NC Green (17) NC Black (16)
White/Blue (24) Yellow (11) White/Green (23) White/Red (19) Red (6) White/Brown (18) NC Gray (15) Black (2) Violet (14)
2 4 6 8
1 3 5 7
Blue (13) Green (12) White/Violet (25) White/Yellow (22) Orange (9) White/Orange (21) NC White/Black (17) Brown (4) White (16)
6 8
10 9
10 9
10 9 12 11 14 13 16 15 18 17 20 19
12 11 14 13 16 15 18 17
12 11 14 13 16 15 18 17 20 19
Black (14)
20 19
Black (16)
Black (14)
1492-ACABLE___X
1492-ACABLE___Y
1492-ACABLE___Z
151
Pinouts, Continued
NC NC NC NC NC
2 4 6 8 10
1 3 5 7 9
2 4 6 8 10
1 3 5 7 9
NC NC NC
1492-ACAB___AA69
1492-ACAB___AB69
Red(3) Black (1) Violet (15) White (17) Orange (6) Yellow (12) White/Violet (25) White/Green (23) White/Red (20)
1 3 5 7 9 11 13 15 17
2 4 6 8 10 12 14 16 18
Brown (2) Blue (14) Gray (16) White/Black (18) White/Brown (19) Green (13) White/Blue (24) White/Yellow (22) White/Orange (21)
2 4 6 8 10 12 14 16 18
1 3 5 7 9 11 13 15 17
Red (8) White (14) Green (12) Blue (10) Black (9)
1492-ACAB___A46
1492-ACAB___BA69
2 4 6 8 10 12 14 16 18
1 3 5 7 9 11 13 15 17
Red (8) White (14) Green (12) Blue (10) Black (9)
1 3 5 7 9 11 13 15 17
NC NC NC NC NC
4 6 8 10 12 14 16 18
NC NC NC NC NC
Red (8) Black (15) White (14) Black (13) Green (12) Black (11) Blue (10) Black (9) NC NC NC NC NC
2 4 6 8 10 12 14 16 18
1 3 5 7 9 11 13 15 17
Red (8) Black (15) White (14) Black (13) Green (12) Black (11) Blue (10) Black (9)
1492-ACAB___BB69
1492-ACAB___BC69
1492-ACAB___BD69
152
Dimensions
Digital IFM Mating Connector
38 mm (1.50 in.) 54.4 mm (2.15 in.) 39 mm (1.54 in.) 29 mm (1.15 in.)
1.6 in. 39 mm
1.8 in. 44 mm
2.3 in. 58 mm
153
2.74 in. (69.5 mm) 2.19 in. (55.5 mm) 1.67 in. (42.5 mm)
154
155
8.27 in. (210 mm) 2.19 in. (55.5 mm) 1.67 in. (42.5 mm) 2.78 in. (70.5 mm)
2.74 in. (69.5 mm) 2.19 in. (55.5 mm) 1.67 in. (42.5 mm) 2.78 in. (70.5 mm)
156
157
8.27 in. (210 mm) 2.19 in. (55.5 mm) 1.67 in. (42.5 mm) 2.78 in. (70.5 mm)
158
159
160
AIFM Dimensions
Cat. No. 1492-AIFM4-3
2.74 in. (69.5 mm) 2.19 in. (55.5 mm) 1.67 in. (42.5 mm)
2.74 in. (69.5 mm) 2.19 in. (55.5 mm) 1.67 in. (42.5 in.)
2.74 in. (69.5 mm) 2.19 in. (55.5 mm) 1.67 in. (42.5 in.)
2.74 in. (69.5 mm) 2.19 in. (55.5 mm) 1.67 in. (42.5 mm) 4.33 in. (110 mm) 3.27 in. (83 mm)
161
2.74 in. (69.5 mm) 2.19 in. (55.5 mm) 1.67 in. (42.5 mm) 4.72 in. (120 mm) 3.27 in. (83 mm)
162
Marking Systems
163
Part 1 of Adhesive Label Card for Cat. Nos. 1492-IFM20F, -IFM20D24, and -IFM20D120
164
Part 2 of Adhesive Label Card for Cat. Nos. 1492-IFM20F, -IFM20D24, and -IFM20D120
165
166
Part 1 of Adhesive Label Card for Cat. Nos. 1492-IFM20F-2, -IFM20D24-2, -IFM20D120-2, -IFM20F-F-2, -IFM20F-F24-2, -IFM20F-F120-2, and -IFM20D240-2
D igital/Analog Programm ab le Co ntroller W irin g Systems
167
Part 2 of Adhesive Label Card for Cat. Nos. 1492-IFM20F-2, -IFM20D24-2, -IFM20D120-2, -IFM20F-F-2, -IFM20F-F24-2, -IFM20F-F120-2, and -IFM20D240-2
168
Adhesive Label Card for Cat. Nos. 1492-IFM20F-2, -IFM20D24-2, -IFM20F-F-2, and -IFM20F-F24-2
MODULE LABEL
IN 1 IN 2 L1 IN 3 IN 4 IN 5 IN 6 IN 7 IN 8 IN 9 IN 10 IN 11 IN 12 L1 IN 13 IN 14 IN 15 L2 L2
LEVEL
Upper Lower
1769-IQ16 SINK
COM COM 1 1
IN 0
IN 1
IN IN 2 3 +VDC 1
IN 4
IN 5
IN 6
IN 7
IN 8
IN 9
IN 10
IN 11
IN IN 12 13 +VDC 2
IN 14
IN COM COM 15 2 2
Upper Lower
IN 0
IN 1
IN IN 2 3 COM 1
IN 4
IN 5
IN 6
IN 7
IN 8
IN 9
IN 10
IN 11
IN IN 12 13 COM 2
IN 14
IN 15
VDC VDC 2 2
Upper Lower
L1 1
OUT 0
OUT 1 L2 1
OUT 2
OUT 3
L1 1
OUT 4
OUT 5
OUT 6 L2 2
OUT 7
L1 2
L1 2
Upper Lower
1769-OW8 (DC)
+VDC 1
OUT 0
OUT 1 COM 1
OUT 2
OUT 5
OUT 6 COM 2
OUT 7
+VDC +VDC 2 2
Upper Lower
1769-OB16
OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT COM COM +VDC +VDC OUT 7 1 3 5 9 2 4 6 8 10 11 12 13 14 15 0 COM COM
Upper Lower
1769-OV16
OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT COM COM +VDC +VDC OUT 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 +VDC +VDC
Upper Lower
1
NUMERIC
5 25
6 26 11 12 03 04
7 27 13 14 04 05
8 28 15 16 05
9 29 17 18 06 06
10 30 19 20 07 07
11
12 32
13 33 25 26 12
14 34 27 28 13 12
15 35 29 30 14 13
16 36 31 32 15 14
17 37 33 34 16 15
18 38 35 36 17
19 20 39 40 37 39 38 40
1 2
LED LABEL FUSE LABEL
3 4
5 6 00
7 8 01 02
9 10 02 03
21 22 10 10
23 24 11 11
00
01
16
17
45006-237-01 (A)
169
Adhesive Label Card for Cat. Nos. 1492-IFM20F-F240-2, -IFM20F-FS120-4, and -IFM20F-FS240-4
MODULE LABEL
L1 OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 L1 OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT 1 00 01 02 03 04 05 06 07 10 11 12 13 14 15 L2 L2 2 1 OUT 14 OUT 16 OUT L1 15 2 OUT L1 17 2 L1 2 L1 2
LEVEL
Upper Upper Lower
1746-OW16 (DC)
+V1 +V1 OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT 0 1 2 3 4 5 6 7 8 9 OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT +V1 +V1 00 01 02 03 04 05 06 07 10 11 COM 1
OUT 10 OUT 12
OUT 11 OUT 13
OUT 14 OUT 16
L2 0 L2 0
L2 1 L2 1
L2 2 L2 2
L2 3 L2 3
L2 4 L2 4
L2 5 L2 5
L2 6 L2 6
L2 7 L2 7
Upper Lower
COM COM COM COM COM COM COM COM OUT OUT OUT OUT OUT OUT OUT OUT 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 COM COM COM COM COM COM COM COM 0 1 2 3 4 5 6 7 +V0 +V1 +V2 +V3 +V4 +V5 +V6 +V7
Upper Lower
L2 0 L2 0
L2 0 L2 0
L2 0 L2 0
L2 0 L2 0
L2 1 L2 1
L2 1 L2 1
L2 1 L2 1
L2 1 L2 1
Upper Lower
1756-OA16 TC-ODA161
L1 0
L2 OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT L1 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 L2 L2 1 0
L2 1
Upper Lower
L1 1 L1 1
L2 1 L2 1
L2 1 L2 1
L2 1 L2 1
L1 2 L1 2
L2 2 L2 2
L2 2 L2 2
Upper Lower
1769-OW8 (DC)
+VDC COM COM COM +VDC COM COM COM OUT OUT OUT OUT OUT OUT OUT OUT 1 1 1 0 1 2 3 4 5 6 7 2 2 2 2 1 +VDC COM COM COM +VDC COM COM COM 1 1 1 1 2 2 2 2
Upper Lower
1771-OMD
L1
L1
OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 L1 L2 L2
L2
Upper Lower
NUMERIC
1 21 1 2
6 26
7 27 13 14
8 28 15 16
9 29 17 18
10 30 19 20
11 31 21 22
12 32 23 24
13 33 25 26
14 34 27 28
15 35 29 30
16 36 31 32
17 37 33 34
18 38 35 36
19 39 37 38
20 40 39 40
3 4
5 6
7 8
9 10
11 12
LED LABEL
1 1 2
2 3 4
3 5 6
4 7 9 8
5 10 11
6 12 13
7 14 15
8 16
45006-110-01 (E)
170
MODULE LABEL
LEVEL
IN L2
Upper Upper
IN L2 L2
IN 2
IN 00 L1 NUMERIC
IN 3 IN
IN 4 IN
IN 5 IN 05
IN 6 IN 06
IN 7 IN 07
IN 8 IN 10
IN 9 IN 11
IN 10 IN 12
IN 11 IN 13
IN 12 IN 14
IN 13 IN 15
IN 14 IN 16
IN 15 IN 17
1 32 23 2 24 00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 10 11 12 13 14 15 16 17 26 28 30 32 34 36 38 40 25 27 29 31 33 35 37 39 33 34 35 36 37 38 39 40
10
11
12
13
14
15
16
17
18
19
20
IN 0 IN 00 +V +V
Upper Upper
IN 1 IN 01
IN 2 IN 02
IN 3 IN 03
IN 4 IN 04
IN 5 IN 05
IN 6 IN 06
IN 7 IN 07
IN 8 IN 10
IN 9 IN 11
IN 10 IN 12
IN 11 IN 13
IN 12 IN 14
IN 13 IN 15
IN 14 IN 16
+V +V LED LABEL
Lower
1746-IV16, ITV16 +V
IN 0 IN 00 COM L2 0
Upper
IN 1 IN 01
IN 2 IN 02
IN 3 IN 03
IN 4 IN 04
IN 5 IN 05
IN 6 IN 06
IN 7 IN 07
IN 8 IN 10
IN 9 IN 11
IN 10 IN 12
IN 11 IN 13
IN 12 IN 14
IN 13 IN 15
IN 14 IN 16
IN 15 IN 17
1756-IA8D TC-IDX081
L1 0
IN 0
IN 1
IN 2
IN 3
L2 0
L2 0
00 1
FUSE LABEL
01 2 01 02 03 04 05 06 07 10 11 12 13 3 4 5 6 7 8 9 10 11 12 13 14 14 15
02
03
04
05 06
07
10
11
12
13
14 15
16 15 16
17 16 17
L1
Lower
1756-IA16 TC-IDA161
Upper
L2 0
L2 0
IN 0
IN 1
IN 2
IN 3
IN 4
IN 5
IN 6
IN 7
IN 8
IN 9
IN 10
IN 11
IN 12
IN 13
IN 14
IN 15
L2 1
L2 1
00
L1
Lower
1756-IB16 TC-IDD161 IN 6
Upper Lower 45006-086-01 (D)
IN 0
IN 1
IN 2
IN 3
IN 4
IN 5
IN 7
IN 8
IN 9
IN 10
IN 11
IN 12
IN 13
IN 14
IN 15
GND GND 1 1
1756-IN16 L1 IN 6 L2
Lower
L2 0
L2 0
IN 0
IN 1
IN 2
IN 3
IN 4
IN 5
IN 7
IN 8
IN 9
IN 10
IN 11
IN 12
IN 13
IN 14
IN 15
L2 1
L2 1
1769-IA16 L2
Upper
L2 L1 IN 6
Upper Lower
L2
IN 0
IN 1
IN 2
IN 3
IN 4
IN 5
IN 7
IN 8
IN 9
IN 10
IN 11
IN 12
IN 13
IN 14
IN 15
IN COM COM 0
IN 1
IN 2
IN 3
IN 4
IN 5
IN 7
IN 8
IN 9
IN 10
IN 11
IN 12
IN 13
IN 14
IN 15 COM COM
IN +VDC +VDC 0
IN 1
IN 2
IN 3
IN 4
IN 5
IN 7
IN 8
IN 9
IN 10
IN 11
IN 12
IN 13
IN 14
IN + VDC 15 +VDC+
1769-IM12 L2 L1 IN 06 L2
Upper Lower
IN 0 IN 7 IN 8 IN 9 IN 10 IN 11
IN 1
IN 2
IN 3
IN 4
IN 5
L1
IN 00 IN 07 IN 10 IN 11 IN 12 IN 13 IN 14 IN 15 IN 16 IN 17
IN 01
IN 02
IN 03
IN 04
IN 05
1771-IMD L1 IN 06 COM
Upper Lower
IN 00 IN 07 IN 10 IN 11 IN 12 IN 13 IN 14 IN 15 IN 16 IN 17
01
IN 02
IN 03
IN 04
IN 05
+V
IN 00 IN 07 IN 10 IN 11 IN 12 IN 13 IN 14 IN 15 IN 16 IN 17
01
IN 02
IN 03
IN 04
IN 05
1771-IBD, ICD +V
Adhesive Label Card for Cat. No. 1492-IFM20D24A-2, -IFM20D120A-2, and -IFM20D240A-2
IN 00 IN 07 IN 10 IN 11 IN 12 IN 13 IN 14 IN 15 IN 16 IN 17
01
IN 02
IN 03
IN 04
IN 05
171
172
Part 1 of Adhesive Label Card for Cat. Nos. 1492-IFM40F-2, -IFM40D24-2, -IFM40D24A-2, -IFM40D120-2, -IFM40D120A-2, -IFM40F-F-2, -IFM40F-F24-2, and -IFM40F-F120-2
D igital/Analog Programm ab le Co ntroller W irin g Systems
173
Part 2 of Adhesive Label Card for Cat. Nos. 1492-IFM40F-2, -IFM40D24-2, -IFM40D24A-2, -IFM40D120-2, -IFM40D120A-2, -IFM40F-F-2, -IFM40F-F24-2, and -IFM40F-F120-2
GROUP 3 INPUTS
174
Part 1 of Adhesive Label Card for Cat. Nos. 1492-IFM20FN, -IFM20D24N, and -IFM20D120N
MODULE LABEL IN 10 IN 2 IN 12 IN 02 IN 10 IN 2 IN 12 IN 02 IN 10 IN 2 IN 12 IN 02 IN 10 IN 2 IN 12 IN 02 OUT 10 OUT 2 OUT 12 OUT 02 OUT 10 OUT 2 OUT 12 OUT 02 OUT 10 OUT 2 OUT 12 OUT 02 OUT 5 OUT 1 OUT +V4 5 OUT +V1 1 L2 L2 1 1 IN IN 1 2 IN 11 IN 3 IN 13 IN 03 IN 11 IN 3 IN 13 IN 03 IN 11 IN 3 IN 13 IN 03 IN 11 IN 3 IN 13 IN 03 OUT 11 OUT 3 OUT 13 OUT 03 OUT 11 OUT 3 OUT 13 OUT 03 OUT 11 OUT 3 OUT 13 OUT 03 L1 5 L1 2 IN 12 IN 4 IN 14 IN 04 IN 12 IN 4 IN 14 IN 04 IN 12 IN 4 IN 14 IN 04 IN 12 IN 4 IN 14 IN 04 OUT 12 OUT 4 OUT 14 OUT 04 OUT 12 OUT 4 OUT 14 OUT 04 OUT 12 OUT 4 OUT 14 OUT 04 OUT 6 OUT 2 OUT +V5 6 OUT +V2 2 L2 IN 1 4 IN L2 3 0 IN 13 IN 5 IN 15 IN 05 IN 13 IN 5 IN 15 IN 05 IN 13 IN 5 IN 15 IN 05 IN 13 IN 5 IN 15 IN 05 OUT 13 OUT 5 OUT 15 OUT 05 OUT 13 OUT 5 OUT 15 OUT 05 OUT 13 OUT 5 OUT 15 OUT 05 L1 6 L1 3 IN 14 IN 6 IN 16 IN 06 IN 14 IN 6 IN 16 IN 06 IN 14 IN 6 IN 16 IN 06 IN 14 IN 6 IN 16 IN 06 OUT 14 OUT 6 OUT 16 OUT 06 OUT 14 OUT 6 OUT 16 OUT 06 OUT 14 OUT 6 OUT 16 OUT 06 OUT 7 OUT 3 OUT +V6 7 OUT +V3 3 IN IN 5 6 L2 L2 0 0 IN 15 IN 7 IN 17 IN 07 IN 15 IN 7 IN 17 IN 07 IN 15 IN 7 IN 17 IN 07 IN 15 IN 7 IN 17 IN 07 OUT 15 OUT 7 OUT 17 OUT 07 OUT 15 OUT 7 OUT 17 OUT 07 OUT 15 OUT 7 OUT 17 OUT 07 L1 7 L2 L2 L2 L2 COM COM COM COM COM COM COM COM +V +V +V +V L2 L1 L2 L1 COM COM COM COM COM +V COM +V
LEVEL Upper Lower Upper Lower Upper Lower Upper Lower Upper Lower Upper Lower Upper Lower Upper Lower Upper Lower Upper Lower Upper Lower Upper Lower Upper Lower Upper Lower Upper Lower +V7 Upper Lower IN 7 L2 0 L2 1 L1 1 Upper Lower
1746-IG16
1746-IV16, ITV16
1771-IBD, ICD
1771-IGD
1771-OBD, OGD
L2 IN 0 8 L2 IN 0 0 GND IN 0 8 GND IN 0 0 OUT L1 0 1 L1 OUT 0 1 L2 L1 0 1 OUT 0 L2 OUT 0 8 L1 OUT 0 0 OUT +DC 0 1 +DC OUT 0 1 RTN OUT 0 8 +DC OUT 0 0 IN 10 L1 IN 00 IN 10 IN +V 00 IN 10 IN 00 IN +V 10 +V IN 00 +V OUT 10 OUT +V 00
IN 9 IN 1 IN 9 IN 1 L1 1 OUT 2 L1 1 OUT 1 OUT 9 OUT 1 +DC 1 OUT 2 OUT 9 OUT 1 IN 11 IN 01 IN 11 IN 01 IN 11 IN 01 IN 11 IN 01 OUT 11 OUT 01
IN 10 IN 2 IN 10 IN 2 L1 1 OUT 3 L1 1 OUT 2 OUT 10 OUT 2 +DC 1 OUT 3 OUT 10 OUT 2 IN 12 IN 02 IN 12 IN 02 IN 12 IN 02 IN 12 IN 02 OUT 12 OUT 02
IN 11 IN 3 IN 11 IN 3 L1 1
IN 12 IN 4 IN 12 IN 4 OUT 4 L1 0 OUT 4 L1 0 OUT 12 OUT 4 OUT 4 +DC 0 OUT 12 OUT 4 IN 14 IN 04 IN 14 IN 04 IN 14 IN 04 IN 14 IN 04 OUT 14 OUT 04
IN 13 IN 5 IN 13 IN 5 OUT 5 L1 0 OUT 5 L1 0 OUT 13 OUT 5 OUT 5 +DC 0 OUT 13 OUT 5 IN 15 IN 05 IN 15 IN 05 IN 15 IN 05 IN 15 IN 05 OUT 15 OUT 05
IN 14 IN 6 IN 14 IN 6 OUT 6 L1 0 OUT 6 L1 0 OUT 14 OUT 6 OUT 6 +DC 0 OUT 14 OUT 6 IN 16 IN 06 IN 16 IN 06 IN 16 IN 06 IN 16 IN 06 OUT 16 OUT 06
IN 15 IN 7 IN 15 IN 7 OUT 7 L1 0 OUT 7 L1 0 OUT 15 OUT 7 OUT 7 RTN 0 OUT 15 OUT 7 IN 17 IN 07 IN 17 IN 07 IN 17 IN 07 IN 17 IN 07 OUT 17 OUT 07
L2 1 L2 1 GND 1 GND 1 L1 1
Upper Lower Upper Lower Upper Lower Upper Lower Upper Lower
COM
Upper Lower
COM
Upper Lower
COM +V COM +V
1746-OW16 (DC)
NUMERIC
1 11 1 2
2 12 3 4 10 00
3 13 5 6 11 01
4 14 7 8 12 02
5 15 9 10 13 03
6 16 11 12 14 04
7 17 13 14 15 05
8 18 15 16 16 06
9 19 17 18 17 07
10 20 19 20
1746-OX8 (AC)
1746-OX8 (DC)
LED LABEL
1756-IA8D TC-IDX081
44006-274-02 (D)
175
Part 2 of Adhesive Label Card for Cat. Nos. 1492-IFM20FN, -IFM20D24N, and -IFM20D120N
MODULE LABEL IN 10 IN 2 IN 11 IN 3 IN 12 IN 4 IN 13 IN 5 IN 14 IN 6 IN 15 IN 7 L2 L2
1769-IQ16 SINK
COM IN 8 1 COM IN 1 0
IN 9 IN 1
IN 10 IN 2
IN 11 IN 3
IN 12 IN 4
IN 13 IN 5
IN 14 IN 6
IN COM 15 2 IN COM 7 2
Upper Lower
1769-IQ16 SOURCE
+VDC IN 1 8 +VDC IN 1 0
IN 9 IN 1
IN 10 IN 2
IN 11 IN 3
IN 12 IN 4
IN 13 IN 5
IN 14 IN 6
IN +VDC 2 15 IN +VDC 7 2
Upper Lower
OUT 4 OUT 0
OUT 5 OUT 1
OUT 6 OUT 2
OUT 7 OUT 3
L1 1
L1 2 L1 2
Upper Lower
1769-OW8 (DC)
OUT 5 OUT 1
OUT 6 OUT 2
Upper Lower
1769-OB16, -OV16
+VDC IN 8 IN +VDC 0
IN 9 IN 1
IN 10 IN 2
IN 11 IN 3
IN 12 IN 4
IN 13 IN 5
IN 14 IN 6
IN COM 15 IN 7 COM
Upper Lower
1769-IA8I
IN 4 IN 0
L2 4 L2 0
IN 5 IN 1
L2 5 L2 1
IN 6 IN 2
L2 6 L2 2
IN 7 IN 3
L2 7 L2 3
Upper Lower
NUMERIC
1 11 1 2
2 12 3 4 10 00
3 13 5 6 11 01
4 14 7 8 12 02
5 15 9 10 13 03
6 16 11 12 14 04
7 17 13 14 15 05
8 18 15 16 16 06
9 19 17 18 17 07
10 20 19 20
LED LABEL
45006-236-01 (C)
176
MODULE LABEL
OUT 0 L2 4 OUT 0 COM 4 OUT 0 L2 1 OUT 0 L2 1 OUT 0 COM 1 OUT 0 L2 L2 L2 L2 L2 L2 L2 L2 L2 1 1 1 1 1 1 1 1 2 OUT 0 COM COM COM COM COM COM COM COM COM 1 1 1 1 1 1 1 1 2 L1 1 L2 0 DC 1 COM 0 L1 0 L2 0 L1 0 L2 0 +DC 0 COM 0 L1 2 L2 1 DC 2 COM 1 L1 0 L2 0 L1 0 L2 0 +DC 0 COM 0 L1 3 L2 1 DC 3 COM 1 L1 0 L2 0 L1 0 L2 0 +DC 0 COM 0 L1 4 L2 2 DC 4 COM 2 L1 1 L2 0 L1 1 L2 0 +DC 1 COM 0 L1 5 L2 2 DC 5 COM 2 L1 1 L2 0 L1 1 L2 0 +DC 1 COM 0 L1 6 L2 3 DC 6 COM 3 L1 1 L2 0 L1 1 L2 0 +DC 1 COM 0 L1 7 L2 3 DC 7 COM 3 L1 1 L2 0 L1 1 L2 0 +DC 1 COM 0 OUT 1 L2 4 OUT 1 COM 4 OUT 1 L2 1 OUT 1 L2 1 OUT 1 COM 1 OUT 1 L2 2 OUT 1 COM 2 OUT 2 L2 5 OUT 2 COM 5 OUT 2 L2 1 OUT 2 L2 1 OUT 2 COM 1 OUT 2 L2 2 OUT 2 COM 2 OUT 3 L2 5 OUT 3 COM 5 OUT 3 L2 1 OUT 3 L2 1 OUT 3 COM 1 OUT 3 L2 2 OUT 3 COM 2 OUT 4 L2 6 OUT 4 COM 6 OUT 4 L2 1 OUT 4 L2 1 OUT 4 COM 1 OUT 4 L2 2 OUT 4 COM 2 OUT 5 L2 6 OUT 5 COM 6 OUT 5 L2 1 OUT 5 L2 1 OUT 5 COM 1 OUT 5 L2 2 OUT 5 COM 2 OUT 6 L2 7 OUT 6 COM 7 OUT 6 L2 1 OUT 6 L2 1 OUT 6 COM 1 OUT 6 L2 2 OUT 6 COM 2 OUT 7 L2 7 OUT 7 COM 7 OUT 7 L2 1 OUT 7 L2 1 OUT 7 COM 1 OUT 7 L2 2 OUT 7 COM 2
LEVEL
UPPER LOWER UPPER LOWER UPPER ZCL2 1 1 L1 L1 1 1 LOWER UPPER LOWER RTN RTN 1 1 RTN RTN 1 1 L1 2 L1 2 +VDC 2 +VDC 2 UPPER LOWER UPPER LOWER UPPER LOWER
1756-OA8D, 1756-OA8E, TC-ODX081 1756-OA8, 1756-ON8, TC-ODC081 1756-OB8, -OC8, TC-ODD081, TC-ODE081 1769-OA8 (AC), -OW8
1769-OW8 (DC)
LED
1
1 21 2 22 3 4 3 23 5 6 4 24 7 8 5
2
6 26 11 12 7 27 13 14 25 9 10
3
8 28 15 16 9 29 17 18
4
10 30 19 20 11 31 21 22
5
12 32 23 24 13 33 25 26
6
14 34 27 28 15 35 29 30
7
16 36 31 32 17 37 33 34
8
18 38 35 36 19 39 37 38 20 40 39 40
NUMERIC
1 2
45006-056-01 (E)
177
Adhesive Label Card for Cat. Nos. 1492-IFM20F-FS-2, -IFM20F-FS24-2, and -IFM20F-FS120-2
I/0 CAT. NO. 1746-OX8 (AC) 1769-OW8I (AC) 1746-OX8 (DC) 1769-OW8I (DC) 1756-OA8D 1756-OA8E TC-ODX081 1756-OA8 1756-ON8 TC-ODC081 1756-OB8 1756-OC8 TC-ODD081 TC-ODE081 1769-OA8 (AC), OW8 1769-OW8 (DC) 0 0L1 0 +V0 0 0L2 0L1 0L1 0 0L1 R0 R0 0 +V0 1 1L1 1 +V1 1 0L1 1 0L1 1 +V0 2
MODULE LABEL 3 3L1 3 +V3 3 0L1 3 0L1 3 +V0 4 4L1 4 +V4 4 1L1 4 1L1 4 +V1 5 5L1 5 +V5 5 1L1 5 1L1 5 +V1 6 6L1 6 +V6 6 1L1 6 1L1 6 +V1 7 7L1 7 +V7 7 1L1 7 1L1 7 +V1 R1 R1 1L2 1L1
LEVEL UPPER LOWER UPPER LOWER UPPER LOWER UPPER LOWER UPPER LOWER
L1 OUT OUT OUT OUT OUT OUT OUT OUT L1 1 0 1 2 3 4 5 6 7 2 L1 L1 1 2 +VDC OUT OUT OUT OUT OUT OUT OUT OUT +VDC 1 0 1 2 3 4 5 6 7 2 +VDC +VDC 1 2
NUMERIC
1 11 1 2
2 12 3 4
3 13 5 6
4 14 7 8
5 15 9 10
6 16 11 12
7 17 13 14
8 18 15 16
9 19 17 17
10 20 19 20
LED LABEL
45006-022-01 (D)
178
MODULE LABEL
IN 0 L1 0F IN 0 L1 OF IN 0 +DC 0F IN 1 L1 0F IN 1 L1 1F IN 1 1F IN 2 L1 0F IN 2 L1 2F IN 2 2F IN 3 L1 0F IN 3 L1 3F IN 3 3F IN 4 L1 1F IN 4 L1 4F IN 4 4F IN 5 L1 1F IN 5 L1 5F IN 5 5F IN IN L1 6 7 0 L1 L1 L1 1F 1F 1 IN IN L1 6 7 L1 L1 6F 7F L1 IN IN +DC 6 7 +DC +DC +DC 6F 7F
LEVEL
UPPER LOWER UPPER LOWER UPPER LOWER
LED NUMERIC
1
1
2
3 4
3
5 6
4
7 21 8
5
9 23 17 18 22 15 16
6
10 24 19 20 11 25 21 22
7
12 26 23 24 13 27 25 26
8
14 28 27 28
5 2 4 6
7 8
9 12
13 14
45006-120-01 (B)
179
Part 1 of Adhesive Label Card for Cat. Nos. 1492-IFM20D24-3, -IFM40F-3, and -IFM40D24-3
180
Part 2 of Adhesive Label Card for Cat. Nos. 1492-IFM20D24-3, -IFM40F-3, and -IFM40D24-3
MODULE LABEL
LEVEL
+V-A
+V-A
IN IN IN IN IN IN IN IN IN IN IN IN IN IN IN IN 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 IN IN IN IN IN IN IN IN IN IN IN IN IN IN IN IN 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 +V +V +V +V +V +V +V +V +V +V +V +V +V +V +V +V 0F 1F 2F 3F 4F 5F 6F 7F 8F 9F 10F 11F 12F 13F 14F 15F +V +V +V +V +V +V +V +V +V +V +V +V +V +V +V +V 00F 01F 02F 03F 04F 05F 06F 07F 10F 11F 12F 13F 14F 15F 16F 17F
1 31 38 39 40 35 37 39 36 38 40 14 15 16 32 23 24 10 11 12 13 26 28 30 32 34 25 27 29 31 33 33 34 35 36 37
10
11
12
13
14
15
16
17
18
19
20
IN 1 L2 L2 LED LABEL L2
IN 2
1 2 1 2 3 4 5 6 7 8 9 6 8 22
IN 0 IN L1 L1 L1 L1 L1
IN 3 IN
IN 4 IN
IN 5 IN
L1-A
L1-A
IN 6 IN 06 L1 6F L1
IN 7 IN 07 L1 7F L1
IN 8 IN 10 L1 8F L1
IN 9 IN 11 L1
IN 10 IN 12 L1
IN 11 IN 13 L1
IN 12 IN 14 L1
21
+V
OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT 5 6 7 11 12 13 14 15
+V-A +V +V +V
06 +V 6F +V +V +V
+V-A +V-A
07 +V 7F +V
10 +V 8F +V
14 +V
IN Upper Lower 6F 7F 8F 9F
IN 2
IN 3
IN 4
IN 5
IN 6
IN 7
IN 8
IN 9
IN 10
IN 11
IN 12
IN 13
IN 14
1756-IA16, IN16 TC-IDA161 IN 5 L1 5F Upper Lower IN 6 L1 6F IN 7 L1 7F IN 8 L1 8F IN 9 L1 9F IN 10 L1 IN 11 L1 IN IN IN IN L2 L2 12 13 14 15 1 1 L1 L1 L1 L1 12F 13F 14F 15F L1-B L1-B
L2 0
L2 0
IN
IN
IN 2
IN 3
IN 4
L1-A L1-A
L2
L2
IN
IN
IN 2
IN 3
IN 4
L1
L1
L1 0F
IN 5 L1 5F
IN 6 L1 6F
IN 7 L1 7F
IN 8 L1 8F
IN 9 L1 9F
IN 10 L1
IN 11 L1
+VDC +VDC
+VDC +VDC +V 0F
OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT OUT 5 6 7 8 9 10 11 12 13 14 15 COM COM +V +V +V +V +V +V +V +V +V +V +VDC +VDC 6F 7F 8F 9F 12F 13F 14F 15F
IN IN IN IN IN IN IN IN IN IN IN IN IN IN IN IN COM 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 +V-A +V-A +V +V +V +V +V +V +V +V +V +V +V +V +V +V +V +V +V-B +V-B 00F 01F 02F 03F 04F 05F 06F 07F 10F 11F 12F 13F 14F 15F 16F 17F
1771-IAD (AC) IND (AC) Upper Lower IN IN IN IN IN IN L2 12 13 14 15 16 17 L1 L1 L1 L1 L1 L1 L1-B L1-B 12F 13F 14F 15F 16F 17F
IN IN IN IN IN IN IN IN IN IN 00 01 02 03 04 05 06 07 10 11 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1-A L1-A 00F 01F 02F 03F 04F 05F 06F 07F 10F 119F
L1
Upper Lower
IN IN IN IN IN IN IN IN IN IN +V 00 01 02 03 04 05 06 07 10 11 +V-A +V-A +V +V +V +V +V +V +V +V +V +V 00F 01F 02F 03F 04F 05F 06F 07F 10F 119F
181
182
Adhesive Label Card for Cat. Nos. 1492-IFM40DS24-4, -IFM40DS24A-4, -IFM40DS120-4, -IFM40DS120A-4, and -IFM40DS240A-4
183
Adhesive Label Card for Cat. Nos. 1492-IFM40F-FS-2, -IFM40F-FS24-2, and -IFM40F-FS120-2
7 9
8 10 07 10 11 12 13 14 15 16 17 11 12 13 14 15 16
00
01
02
03
04
05
06
184
MODULE LABEL
L2 9 L2 9 4 RTN 4 GND GND COM COM 9 10 L2 L2 4 5 L2 L2 4 5 4 4 5 5 14 L2 7 L2 7 7 7 L2 10 10 5 5 5 5 6 6 L2 14 14 7 7 OUT 0 L1 0 OUT 7 0 RTN +DC 7 0 GND OUT 0 GND +DC 0 OUT 15 L2 7 L2 7 7 7 17 17 +DC 0 OUT 0NC L1 0 0NC 0 00 +V 00 L2 15 L2 15 OUT 1 L1 1 OUT 0 RTN 0 OUT 1 +DC 0 OUT 1 +DC 1 OUT 0NO L1 0 OUT ONO +DC 0 OUT 01 +V 01 OUT 2 OUT OUT 3 4 6 7 8 9 L1 2 3 4 6 7 8 9 OUT 1 1 2 3 3 4 4 RTN 1 1 3 4 4 OUT OUT OUT 9 +DC +DC +DC 1 OUT OUT OUT 9 +DC +DC +DC 2 3 4 6 7 8 9 OUT OUT OUT OUT OUT OUT OUT OUT 1NC 1NO 2NC 2NO 3NC 3NO 4NC 4NO L1 L1 L1 L1 L1 1 1 2 3 3 4 4 OUT 1NC 4NC 4NO +DC 1 1 2 3 3 4 4 02 +V 02 10 +V 10 OUT 10 L1 10 OUT 5 +DC 5 OUT 10 +DC 1 OUT 10 +DC 10 OUT 5NC L1 5 OUT 5NC +DC 5 OUT 11 11 5 RTN 5 OUT +DC OUT 12 12 6 6 6 OUT 15 15 7 RTN
LEVEL
UPPER LOWER UPPER LOWER UPPER GND OUT LOWER UPPER LOWER UPPER LOWER UPPER LOWER UPPER LOWER
1756-OB16D TC-ODX161
L2 1
L2 5 5 5 5
L2 6
L2 6 6 6 6
+DC +DC 11 12 15 OUT OUT OUT OUT OUT 5NO 6NC 6NO 7NC 7NO L1 L1 L1 5 6 6 7 5NO 5 13 +V 13 6 6 7NO 7
OUT OUT 11 12 +V +V 11 12
LED
00 1
1 35 1 2 2 36 3 4
01 2
3 37 5 6 4 38 7 8
02 3
5 39 9 10 6 40 11 12 7 41 13 14
03 4
8 42 15 16 9 43 17 18
04 5
10 44 19 20 11 45 21 22
05 6
12 46 23 24 13 47 25 26
06 7
14 48 27 28 15 49 29 30
07 8
16 50 31 32 17 51 33 34 18 52 35 36
10 9
19 53 37 38 20 54 39 40
11 10
21 55 41 42 22 56 43 44
12 11
23 57 45 46 24 58 47 48
13 12
25 59 49 50 26 60 51 52
14 13
27 61 53 54 28 62 55 56 29 63 57 58
15 14
30 64 59 60 31 65 61 62
16 15
32 66 63 64 33 67 65 66
17 16
34 68 67 68
NUMERIC
45006-047-02 (D )
185
Adhesive Label Card for Cat. Nos. 1492-IFM40F-FS120-4, -IFM40F-FS24A-4, and -IFM40F-FS120A-4
D igital/Analog Programm ab le Co ntroller W irin g Systems
186
Adhesive Label Card for Cat. Nos. 1492-XIM2024-8R, -XIM20120-8R, and -XIM4024-8R
187
188
Adhesive Label Card for Cat. Nos. 1492-XIMF-F24-2, -XIMF-F120-2, and -XIMF-2
189
190
191
MODULE LABEL
C C C C +V +V SH SH SH SH SH SH SH SH SH SH SH SH SH SH 1+ 3 1 3 1 3 1 3+ 1+ 3+ 1+ 3+ 1+ 31O/1 1C C C C RTN RTN 31C C C C -V -V SH SH SH SH SH SH SH SH SH SH SH SH COM SH SH
LEVEL
Upper Lower Upper Lower Upper Lower Upper Lower Upper Lower Upper Lower Upper Lower
0+ COM 3+ 1+ 31-
SH SH SH
1+ COM 4+ 2+ 42-
SH SH SH
NUMERIC
1 9 1 2
2 10 3 4
3 11 5 6
4 12 7 8
5 13 9 10
6 14 11 12
7 15 13 14
8 16 15 16
45006-034-01 (D)
192
193
MODULE LABEL
3+ 34+ 45+ 56+ 67+ 7-
LEVEL
Upper Lower
SHIELD
COM
1746-NI16V
11
12
13
14
15
Upper Lower
SHIELD
COM
1746-NI16I
11
12
13
14
15
Upper Lower
SHIELD
COM
1756-IF8 TC-IAH081
RTN
2 SHIELD
6 RTN RTN 6
RTN
Upper Lower
RTN
RTN
RTN
RTN
Upper Lower
1756-IF16 TC-IAH161
11
12
13
14
15
Upper Lower
RTN 12 13 14 15
Upper Lower
RTN + I RTN 11 12 13 14 15
Upper Lower
RTN 11 12 13 14 15
Upper Lower
SHIELD IN 0 IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 IN 8 IN 9 IN 10
RTN IN 11 IN 12 IN 13 IN 14 IN 15
Upper Lower
SHIELD
RTN
1756-OF8 TC-OAV081
OUT OUT OUT OUT OUT OUT OUT OUT 0 RTN 1 RTN 2 RTN 3 RTN 4 RTN 5 RTN 6 RTN 7 RTN SHIELD RTN
Upper Lower
10
11
12
13
14
15
16
Upper Lower
SHIELD
MODULE COM
194
1771-IFE DIFFERENTIAL
1+
1-
2+
2-
3+
3-
4+
4-
5+
5-
6+
6-
7+
7-
8+
8-
Upper Lower
SHIELD
MODULE COM
1771-IL
1+
1-
2+
2-
3+
3-
4+
4-
5+
5-
6+
6-
7+
7-
8+
8-
Upper Lower
SHIELD
COM
NUMERIC
1 17 1 2
2 18 3 4
3 19 5 6
4 20 7 8
5 21 9 10
6 22 11 12
7 23 13 14
8 24 15 16
9 25 17 18
10 26 19 20
11 27 21 22
12 28 23 24
13 29 25 26
14 30 27 28
15 31 29 30
16 32 31 32
45006-019-01 (D)
195
196
MODULE LABEL
+V 2F 2 +V 3F 3 +V 4F 4 +V 5F 5 +V 6F 6 +V 7F 7 +V 8F 8 SHIELD +V 9F 9 +V +V +V +V +V +V 10F 11F 12F 13F 14F 15F 10 11 12 13 14 15 COM
LEVEL
Upper Middle Lower
1746-NI16V +V
+V 0F 0
+V 1F 1
+V 2F 2
+V 3F 3
+V 4F 4
+V 5F 5
+V 6F 6
+V 7F 7
+V 8F 8
+V 9F 9
SHIELD 1756-IF16 TC-IAH161 +V +V +V +V +V 8 SHIELD +V 0F +V 1F +V 2F +V 3F +V 4F +V 5F +V 6F +V 7F +V 8F +V 9F +V 10F +V 11F +V +V +V +V 12F 13F 14F 15F RTN RTN+ RTN RTN RTN
V1 1
V2 2
V3 3
V4 4
V5 5
V6 6
V7 7
V8 8
V9 9
SHIELD
NUMERIC
1 17 35
10
11
12
13
14
15
16 33 34 51 52
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
LED LABEL
0 0 15
1 1
2 2 15
3 3 15
4 4 15
5 5
6 6
7 7
8 8
9 9
10 10
11 11
12 13 14 12 13 14
45006-107-01 (C)
197
198
199
MODULE LABEL
+V 1F IN -1 SH IN +2 +V 2F IN -2 SH IN +3 +V 3F IN -3 V0 +24 V0 RTN SH IN +4 +V 4F IN -4 SH IN +5 +V 5F IN -5 SH IN +6 +V 6F IN -6 SH IN +7 +V 7F IN -7 V1 OUT OUT +DC 0 1 V1 RTN RTN 1 RTN 0
LEVEL
UPPER LOWER
NUMERIC
1 21 1 2
2 22 3 4
3 23 5 6
4 24 7 8
5 25 9 10
6 26 11 12
7 27 13 14
8 28 15 16
9 29 17 18
10 30 19 20
11 31 21 22
12 32 23 24
13 33 25 26
14 34 27 28
15 35 29 30
16 36 31 32
17 37 33 34
18 38 35 36
19 39 37 38
20 40 39 40
45006-270-01 (A)
200
Accessories
40 fuse holders are included with Cat. Nos.: 1492-IFM40F-FS120-2 1492-IFM40F-FS120-4 1492-IFM40F-FS240-4 1492-IFM40F-FS24A-4 1492-IFM40F-FS120A-4
Replacement fuse holders (Cat. No. 1492-IFMFHI) are available in packages of 20. Cat. No. 1492-IFMFHI fuse holders are not compatible with fusible expandable XIMs.
201
Accessories, Continued
Replacement Relays
The relays in the Relay Master and Relay Expander modules are replaceable. The following replacement relays must be used:
Replacement Relays XIM Cat. No. 1492-XIM4024-16R 1492-XIM4024-8R 1492-XIM2024-8R 1492-XIM20120-8R 1492-XIM24-8R 1492-XIM120-8R Replacement Relay Cat. No. 700-HK36Z24 700-HK36Z24 700-HK36Z24 700-HK36A1 700-HK36Z24 700-HK36A1
202
Accessories, Continued
Visit the following web sites for I/O wiring diagrams of the Interface Modules and cables: for Bulletin 1746 I/O platform: http://www.ab.com/catalogs/b113/slc/wiring.html for Bulletin 1756 I/O platform: http://www.ab.com/catalogs/b113/controllogix/wiring.html for Bulletin 1771 I/O platform: http://www.ab.com/catalogs/b113/plc5/wiring.html For Bulletin 1769 I/O platform: http://www.ab.com/catalogs/b113/micro1500/wiring.html To locate the wiring diagram, navigate to one of the above platform sections of the web site and locate the desired product selection table. Select the desired I/O module, Interface Module, and pre-wired cable combination. A letter will appear in the box for all valid combinations. Wiring diagrams can be located by clicking on the underlined letter in the box.
203
Quick Reference
Digital IFM Specifications
Digital IFM Cat. No. 1492-IFM20F 1492-IFM20FN 1492-IFM20F-2 1492-IFM20F-3 1492-IFM20D24 1492-IFM20D24N 1492-IFM20D24-2 1492-IFM20D24A-2 1492-IFM20DS24-4 1492-IFM20D24-3 1492-IFM20D120 1492-IFM20D120N 1492-IFM20D120-2 1492-IFM20D120A-2 1492-IFM20DS120-4 1492-IFM20D240-2 1492-IFM20D240A-2 1492-IFM20F-F-2 1492-IFM20F-F24-2 1492-IFM20F-F24A-2 1492-IFM20F-F120-2 1492-IFM20F-F120A-2 1492-IFM20F-F240-2 1492-IFM20F-FS-2 1492-IFM20F-FS24-2 1492-IFM20F-FS24A-4 1492-IFM20F-FS120-2 1492-IFM20F-FS120-4 1492-IFM20F-FS120A-4 1492-IFM20F-FS240-4 1492-IFM40F 1492-IFM40F-2 1492-IFM40F-3 1492-IFM40D24 1492-IFM40D24-2 1492-IFM40D24A-2 1492-IFM40DS24-4 1492-IFM40DS24A-4 1492-IFM40D24-3 1492-IFM40D120-2 1492-IFM40D120A-2 1492-IFM40DS120-4 1492-IFM40DS120A-4 1492-IFM40DS240A-4 1492-IFM40F-F-2 1492-IFM40F-F24-2 1492-IFM40F-F120-2 1492-IFM40F-FS-2 1492-IFM40F-FS24-2 1492-IFM40F-FS24-4 1492-IFM40F-FS120-2 1492-IFM40F-FS120-4 1492-IFM40F-FS240-4 1492-IFM40F-FS24A-4 1492-IFM40F-FS120A-4 Voltage Range 0264V AC/DC 0132V AC/DC 0264V AC/DC 0132V AC/DC 1030V AC/DC 1030V AC/DC 1030V AC/DC 1030V AC/DC 1060V AC/DC 1030V AC/DC 85132V AC/DC 85132V AC 85132V AC 85132V AC 85132V AC 204264V AC 204264V AC 0132V AC/DC 1030V AC/DC 1030V AC/DC 85132V AC 85132V AC/DC 204264V AC 0132V AC/DC 1030V AC/DC 1030V AC/DC 85132V AC/DC 85132V AC/DC 85132V AC/DC 204264V AC 0132V AC/DC 0132V AC/DC 060V AC/DC 1030V AC/DC 1030V AC/DC 1030V AC/DC 1060V AC/DC 1030V AC/DC 1030V AC/DC 85132V AC 85132V AC 85132V AC 85132V AC 204264V AC 0132V AC/DC 1030V AC/DC 85132V AC 0132V AC/DC 1030V AC/DC 1030V AC/DC 85132V AC/DC 85132V AC/DC 204264V AC/DC 1030V AC/DC 85132V AC/DC Dimensions (L x W x H) (in.) 4.33 x 3.27 x 2.78 2.36 x 3.27 x 2.78 4.33 x 3.27 x 2.78 4.33 x 3.27 x 2.78 4.33 x 3.27 x 2.78 2.36 x 3.27 x 2.78 4.33 x 3.27 x 2.78 4.33 x 3.27 x 2.78 4.33 x 3.27 x 2.78 4.33 x 3.27 x 2.78 4.33 x 3.27 x 2.78 2.36 x 3.27 x 2.78 4.33 x 3.27 x 2.78 4.33 x 3.27 x 2.78 4.33 x 3.27 x 2.78 4.33 x 3.27 x 2.78 4.33 x 3.27 x 2.78 4.33 x 3.27 x 2.78 4.33 x 3.27 x 2.78 4.33 x 3.27 x 2.78 4.33 x 3.27 x 2.78 4.33 x 3.27 x 2.78 4.72 x 3.27 x 2.78 2.36 x 3.27 x 2.78 2.36 x 3.27 x 2.78 3.15 x 3.27 x 2.78 2.36 x 3.27 x 2.78 4.33 x 3.27 x 2.78 3.15 x 3.27 x 2.78 4.33 x 3.27 x 2.78 4.33 x 3.27 x 2.78 8.27 x 3.27 x 2.78 8.27 x 3.27 x 2.78 4.33 x 3.27 x 2.78 8.27 x 3.27 x 2.78 8.27 x 3.27 x 2.78 6.69 x 3.27 x 2.78 6.69 x 3.27 x 2.78 8.27 x 3.27 x 2.78 8.27 x 3.27 x 2.78 8.27 x 3.27 x 2.78 6.69 x 3.27 x 2.78 6.69 x 3.27 x 2.78 6.69 x 3.27 x 2.78 8.27 x 3.27 x 2.78 8.27 x 3.27 x 2.78 8.27 x 3.27 x 2.78 4.72 x 3.27 x 2.78 4.72 x 3.27 x 2.78 7.09 x 3.27 x 2.78 4.72 x 3.27 x 2.78 7.09 x 3.27 x 2.78 7.09 x 3.27 x 2.78 7.09 x 3.27 x 2.78 7.09 x 3.27 x 2.78 Indicator Circuit Current (Nominal) 2 mA 2 mA 2 mA 2 mA 4.1 mA 2 mA 2.5 mA 2.5 mA 2.5 mA 2.5 mA 2.6 mA 2.5 mA 2.5 mA 2 mA 2 mA 2.5 mA 1.2 mA 1.2 mA 2 mA 2 mA 2.5 mA 2.5 mA 2.2 mA 2.5 mA 2 mA 2 mA 2 mA 4.1 mA 4.1 mA 2 mA 2.5 mA 2.5 mA 2.6 mA 2.6 mA 2.6 mA 2 mA 2.5 mA 2 mA 2 mA 2.5 mA 1.4 mA 1.4 mA 3.1 mA 1.4 mA No. Terminals per Device Common 10 17, 18 1 1 10 20 2 18 2 1 10 20 2 10 20 10 10 10 10 10 1 1 2 2 10 18 1 10 10 2 2 18 10 10 2 2 1 10 10 10 1 1 2 1 2 2 1 1 Label Card Cat. No. 43006-253-01 44006-274-02, 45006-236-01 43006-253-03, 45006-237-01 45006-077-01 43006-253-01 44006-274-02, 45006-236-01 43006-253-03, 45006-237-01 45006-086-01 45006-056-01 43006-253-04 43006-253-01 44006-274-02, 45006-236-01 43006-253-03, 45006-237-01 45006-086-01 45006-056-01 43006-253-03 45006-086-01 43006-253-03, 45006-237-01 43006-253-03, 45006-237-01 45006-100-01 43006-253-03, 45006-237-01 45006-100-01 45006-110-01 45006-022-01 45006-022-01 45006-120-01 45006-022-01 45006-110-01 45006-120-01 45006-110-01 43006-253-02 43006-253-05/06 43006-253-04 43006-253-02 43006-253-05/06 43006-253-05/06 45006-054-01 45006-054-01 43006-253-04 43006-253-05/06 43006-253-05/06 45006-054-01 45006-054-01 45006-054-01 43006-253-05/06 43006-253-05/06 43006-253-05/06 45006-020-01 45006-020-01 45006-047-02 45006-020-01 45006-047-01 45006-047-02 45006-047-01 45006-047-01
204
Relay Master/Expandable Interface Module Specifications Relay Master/Expandable XIM Cat. No. 1492-XIM4024-16R 1492-XIM4024-8R 1492-XIM2024-8R 1492-XIM20120-8R 1492-XIM24-8R 1492-XIM120-8R 1492-XIMF-2 1492-XIMF-F24-2 1492-XIMF-F120-2 General Specifications UL/CSA Approvals Cat. No. 1492- UL Component Recognized, File E113724, Guide No. NRAQ2 CSA Certified, File LR1234, Class 321107, or UL Recognized per Canadian Safety Standards (cUR) (File E113724, Guide No. NRAQ2) J.I. 3000590 600V 2 A (except relays) 12 A (except relays) #22#12 AWG (0.24 mm2) 0.32 in. (8 mm) 3.54.5 lb-in. (0.380.50 Nm) 0+60C Voltage Range 2026V DC 2026V DC 2026V DC 96132V AC 2026V DC 96132V AC 0132V AC/DC 1030V DC 85132V AC Dimensions (L x W x H) (in.) 9.06 x 3.27 x 2.78 6.30 x 3.27 x 2.78 6.30 x 3.27 x 2.78 6.30 x 3.27 x 2.78 6.30 x 3.27 x 2.78 6.30 x 3.27 x 2.78 3.15 x 3.27 x 2.19 3.15 x 3.27 x 2.28 3.15 x 3.27 x 2.28 Indicator Circuit Current (Nominal) 2 mA 2 mA 2 mA 2 mA 2 mA 2 mA 2 mA 2 mA 2 mA No. Terminals per Device Common 16 8 8 8 8 8 8 8 Label Card Cat. No. 45006-254-01 45006-142-01 45006-142-01 45006-142-01 45006-143-01 45006-143-01 45006-144-01 45006-144-01 45006-144-01
CE Approval Factory Mutual Approval Maximum Peak Transient Voltage Maximum Current (per circuit) Maximum Current (per module) Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Operating Temperature Range
205
Notes:
206
Notes: