VIKING HEAVY DUTY PUMPS

SERIES 4195 STANDARD CONSTRUCTION FEATURES


250 PSI (17 BAR) for 100 SSU (20 cSt) and above 150 PSI (10 BAR) for 38 to 100 SSU (3 cSt to 20 cSt) 100 PSI (7 BAR) for below 38 SSU (3 cSt) - 40 F. to + 350F. (- 40 C. to + 176C.) 28 SSU to 15,000 SSU (0.1 cP to 3,300 cSt)

Section Page Issue

144 144.1 B

Pressure Range Temperature Range Viscosity Range

SERIES 4195 Pumps


Cutaway View 35-50-75 GPM Sizes (8-11-17 m/hr)

SERIES 4195 Pumps


Cutaway View 10-20-30 GPM Sizes (2-4.5-7 m/hr)

GPM 10-20-30-35-50-75 (m/hr 2-4.5-7-8-11-17)


(Nominal Rating) Vikings high-speed, heavy-duty Series 4195 pumps are available in capacities of 10, 20, 30, 35, 50 and 75 GPM. The three smaller size pumps can be furnished directly connected to either 1800 or 1200 RPM motors. The three larger sizes directly connected to 1200 RPM motors. (See Series 4195D units shown on page 144.3.) All six sizes of Viking Series 4195 pumps are furnished with single mechanical seals. This seal is a simple selfadjusting, non-leak method of shaft sealing located ahead of the casing ball bearing. The Series 4195 pumps are built for continuous or intermittent duty for such applications as filtering, circulating, transferring, or booster service in general industrial, petroleum and marine uses. NOTE: UL listed pumps for handling flammable liquids require special construction. Externals are high strength cast iron. (Ductile Iron Casing on AS, AK and AL sizes). See Catalog Section 440 for details and pricing information. Model numbers for these pumps must be designated by a suffix -F, eg. GG4195-F or when used with a D drive, GG4195DF. UL listed models must be equipped with either an internal or return-to-tank safety relief valve. Maximum discharge pressure for UL listed models is 125 PSIG.
Values shown represent minimums or maximums. Some special construction or
consideration may be required before a cataloged pump can be applied to an application involving maximum pressure or minimum or maximum temperature and/or viscosity. Certain models have restrictions in pressures and/or viscosities. See specifications, page 144.2, and performance curves. sizes, 1200 RPM on three large sizes.

(Standard Equipment) Pumps are equipped with inner casing ball bearing installed outside of mechanical seal and a radial thrust ball bearing permitting heavy-duty service up to 250 PSI (17 BAR). Bearings are Sealed for Life.

BALL BEARINGS

(Standard Equipment) (AS, AK, AL Sizes) Internal pumping gears (rotor and idler) are constructed of ductile iron for added strength in handling all types of liquids up to 15,000 SSU (3,300 cSt). HL size rotor also furnished in ductile iron.

DUCTILE IRON PARTS

(Standard Equipment) (AS, AK, AL Sizes) A patented pressure lubrication system automatically lubricates the idler bushing. This system provides a constant film of liquid between the idler bushing and idler pin at a pressure equal to the pump discharge pressure regardless of pump rotation.

PRESSURE LUBRICATION

(Standard Equipment) O-Ring gaskets are used between casing and head plate and between casing and relief valve or valve plates. Flat valve gaskets furnished on GG, HJ and HL size pumps. These gaskets provide a positive seal eliminating a chance for leakage at these points.

O-RING GASKETS

Nominal capacities based on handling thin liquids at 1800 RPM on three small
Metric conversions are based on US measurements and rounded to the nearest whole number.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

Section Page Issue

144 144.2 B

VIKING HEAVY DUTY PUMPS


SERIES 4195 STANDARD CONSTRUCTION UNMOUNTED PUMPS
MECHANICAL SEAL Buna-N bellows. Buna-N O-ring. Carbon rotating face (washer). Ni-Resist stationary seat. Steel metal parts. Stainless steel spring.

SERIES 4195 Pumps


GG, HJ and HL Sizes

In addition to the famous features listed on the previous page, Series 4195 heavy-duty pumps are furnished with an integral relief valve as shown in the pump photos above. Return-to-tank valves are also available on all models on request. Note: On the GG, HJ and HL sizes, the valve mounts on the pump head. The AS, AK and AL size value mounts on top of the pump casing. All sizes equipped with Buna-N mechanical seal with carbon rotating and Ni-Resist stationary faces.
Standard Construction Models GG4195 HJ4195 HL4195 AS4195 AK4195 AL4195

SERIES 4195 Pumps


AS, AK and AL Sizes

Dimensions for Unmounted PumpsSee Page 144.6. Performance Data for Unmounted PumpsSee Pages 144.13 through 144.26.

CONSTRUCTION SERIES 4195 (GG THROUGH AL SIZES)


Casing Iron Iron Iron Head Iron Iron Iron Rotor Idler Rotor Shaft and Idler Pin Steel Steel Steel Idler Bushing Carbon Graphite Carbon Graphite Carbon Graphite Internal Safety Relief Valve Iron Iron Iron

Iron
Ductile Iron Ductile Iron

Iron
Iron Ductile Iron

SPECIFICATION UNMOUNTED PUMPS


Model Numbers Unmounted Pump GG4195 HJ4195 HL4195 AS4195 AK4195 Port Size (NPT) Inches 1 1 1 2 2 3 Nominal Pump Rating GPM (m/hr) 10 7 20 13 30 20 35 50 (3) (2) (4.5) (3) (7) (4.5) (8) (11) RPM 1800 1200 1800 1200 1800 1200 1200 1200 Motor Horsepower Required At Rated Speed Pumping 100 SSU Liquid 50 PSI (3.5 BAR) 100 PSI (7 BAR) Maximum Hydrostatic Pressure PSIG (BAR) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) Maximum Pump Discharge Pressure PSIG (BAR) 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU Maximum Temperature Degrees 225F (107C) 225F (107C) 225F (107C) 225F (107C) 225F (107C) 225F (107C) Steel Fitted Construction Recommended Above This Viscosity SSU (cSt) 7500 (1619) 7500 (1619) Approximate Shipping Weight With Valve (Less Power) Pounds (KG) 20 44 44 85 85 (9) (20) (20) (38) (38)


1 1 2 1 2 3

2 1 3 2 3 5 7

AL4195

75

(17)

1200

400 (28)

86

(39)

Standard Buna-N seal from -20F. to +225F. With special construction, temperatures from -40F. to +350F. can be handled with this series. When steel fitted construction is required, GG will have steel rotor, HJ will have ductile iron rotor. GG size has steel idler.
Metric conversions are based on US measurements and rounded to the nearest whole number.

Nominal capacities based on handling thin liquids at 1800 RPM on three small sizes, 1200 RPM on three large sizes. For viscosities above 15,000 SSU (3,300 cSt), provide details for recommendations. These models have ductile iron rotors; steel fitted rotors not necessary. If suction pressure exceeds 100 PSIG (7 BAR), consult factory.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

VIKING HEAVY DUTY PUMPS


SERIES 4195 STANDARD CONSTRUCTION DIRECT DRIVE UNITS (D DRIVE)

Section Page Issue

144 144.3 B

SERIES 4195 Pumps


with D Drive AS, AK and AL Sizes

SERIES 4195 Pumps


with D Drive GG, HJ and HL Sizes

Series 4195 pumps in the GG, HJ and HL size (nominal rating 10, 20, 30 GPM) are designed for high-speed, heavyduty service. The pump is connected by a flexible coupling with guard directly to a 1200 or 1800 RPM motor. Both pump and motor mount on a sturdy formed steel base. This makes a very compact, rugged unit for heavy-duty service, handling many types of fluids up to 15,000 SSU. The three large size Series 4195D direct connected units all feature the 4195 high-speed pump connected by a flexible coupling with guard to 1200 RPM motor. Both pump and SPECIFICATIONS D DRIVE UNITS
Model Numbers Direct Drive GG4195D HJ4195D HL4195D AS4195D AK4195D AL4195D Port Size (NPT) Inches 1 1 1 2 2 3 Nominal Pump Rating GPM (m/hr) 10 7 20 13 30 20 35 50 75 (3) (2) (4.5) (3) (7) (4.5) (8) (11) (17) RPM 1800 1200 1800 1200 1800 1200 1200 1200 1200 Motor Horsepower Required At Rated Speed Pumping 100 SSU Liquid 50 PSI (3.5 BAR) 100 PSI (7 BAR) Maximum Hydrostatic Pressure PSIG (BAR) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28)

motor are mounted on a heavy-duty formed steel base. The three larger sizes are equipped with ductile iron pump gears (rotor and idler). O-Ring head and valve gaskets, mechanical seals and automatic pressure lubrication systems are also standard construction. These pumps are also available with steel externals, see Section 154.
Dimensions for D DriveSee Page 144.7. Performance Data for D DriveSee Pages 144.13 through 144.26.

Maximum Pump Discharge Pressure PSIG (BAR) 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU

Maximum Temperature Degrees 225F (107C) 225F (107C) 225F (107C) 225F (107C) 225F (107C) 225F (107C)

Steel Fitted Construction Recommended Above This Viscosity SSU (cSt) 7500 (1619) 7500 (1619)

Approximate Shipping Weight With Valve (Less Power) Pounds (KG) 46 69 69 (21) (31) (31)


1 1 2 1 2 3 5

2 1 3 2 3 5 7

215 (97) 215 (97) 220 (100)

Nominal capacities based on handling thin liquids at 1800 RPM on three small

sizes, 1200 RPM on three large sizes. With special construction, temperatures to + 350F. can be handled with this series.
Metric conversions are based on US measurements and rounded to the nearest whole number.

For viscosities above 15,000 SSU (3,300 cSt), provide details for recommendations. These models have ductile iron rotors; steel fitted rotors not necessary. If suction pressure exceeds 100 PSIG (7 BAR), consult factory.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

Section Page Issue

144 144.4 B

VIKING HEAVY DUTY PUMPS


SERIES 495 STANDARD CONSTRUCTION FLANGE BRACKET UNMOUNTED PUMPS
Pressure Range Temperature Range Viscosity Range 250 PSI (17 BAR) for 100 SSU (20 cSt) and above 150 PSI (10 BAR) for 38 to 100 SSU (3 cSt to 20 cSt) 100 PSI (7 BAR) for below 38 SSU (3 cSt) - 40 F. to + 350F. (- 40 C. to + 176C.) 28 SSU to 15,000 SSU (0.1 cP to 3,300 cSt)

GG, HJ and HL Sizes

SERIES 495 Pumps

AS, AK and AL Sizes

SERIES 495 Pumps

Series 495 pumps are similar to the Series 4195 on preceding pages with the exception of a flange bracket mount casing.
Standard Construction Models GG495 HJ495 HL495 AS495 AK495 AL495 Mounting Bracket (Units Only) Iron Iron Iron

(Nominal Rating) All six sizes are furnished with single mechanical seals, including Buna-N elastomer gaskets. Standard construction features internal type safety relief valve on pump head or casing (depending on pump size), O-Ring head and valve gaskets, and automatic pressure lubrication system on the three larger size pumps. The 495 series offers an optional flange port for sizes HJ-AL. Contact the factory for details.
Dimensions for Unmounted PumpsSee Page 144.8. Performance Data for Unmounted PumpsSee Pages 144.13 through 144.26.
Rotor Shaft and Idler Pin Steel Steel Steel Internal Safety Relief Valve Iron Iron Iron

GPM 10-20-30-35-50-75 (m/hr 2-4.5-7-8-11-17)

CONSTRUCTION SERIES 495 (GG THROUGH AL SIZES)


Casing Iron Iron Iron Head Iron Iron Iron Rotor Iron Ductile Iron Ductile Iron Idler Iron Iron Ductile Iron Idler Bushing Carbon Graphite Carbon Graphite Carbon Graphite

SPECIFICATION UNMOUNTED PUMPS


Model Numbers Unmounted Pump GG495 HJ495 HL495 AS495 AK495 AL495 Port Size (NPT) Inches 1 1 1 2 2 3 Nominal Pump Rating GPM (m/hr) 10 7 20 13 30 20 35 50 75 (3) (2) (4.5) (3) (7) (4.5) (8) (11) (17) RPM 1800 1200 1800 1200 1800 1200 1200 1200 1200 Motor Horsepower Required At Rated Speed Pumping 100 SSU Liquid 50 PSI (3.5 BAR) 100 PSI (7 BAR) Maximum Hydrostatic Pressure PSIG (BAR) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) Maximum Pump Discharge Pressure PSIG (BAR) 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU Maximum Temperature Degrees 225F (107C) 225F (107C) 225F (107C) 225F (107C) 225F (107C) 225F (107C) Steel Fitted Construction Recommended Above This Viscosity SSU (cSt) 7500 (1619) 7500 (1619) Approximate Shipping Weight With Valve (Less Power) Pounds (KG) 18 40 40 80 80 81 (8) (18) (18) (36) (36) (37)


1 1 2 1 2 3 5

2 1 3 2 3 5 7

Consult factory for specific recommendations. Standard Buna-N seal from -20F. to +225F. With special construction, temperatures from -40F. to +350F. can be handled with this series. For viscosities above 15,000 SSU (3,300 cSt), provide details for recommendations. Nominal capacities based on handling thin liquids at 1800 RPM on three small sizes, 1200 RPM on three large sizes.
Metric conversions are based on US measurements and rounded to the nearest whole number.

Buna-N elastomer used in mechanical seal of Series 495 pumps. When steel fitted construction is required, GG will have steel rotor, HJ will have ductile iron rotor. GG size has steel idler. These models have ductile iron rotors; steel fitted rotors not necessary. If suction pressure exceeds 100 PSIG (7 BAR), consult factory.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

VIKING HEAVY DUTY PUMPS


SERIES 495 STANDARD CONSTRUCTION FLANGE BRACKET MOUNTED UNITS (M DRIVE)

Section Page Issue

144 144.5 B

with M Drive GG, HJ and HL Sizes

SERIES 495 Pumps

with M Drive AS, AK and AL Sizes

SERIES 495 Pumps

For a compact horizontal mounting, the C flange mounted 495M heavy-duty pump units in all six sizes include a combination motor C flange and square pump flange bracket with coupling connecting motor and pump. The three smaller units connect to a foot mounted motor, while the three larger units include a foot type bracket to mount a flange type motor. An optional foot-type bracket is available for the GG-HL sizes. Contact the factory for details. SPECIFICATIONS M DRIVE UNITS
Model Numbers Unmounted Pump GG495M HJ495M HL495M AS495M AK495M AL495M Port Size (NPT) Inches 1 1 1 2 2 3 Nominal Pump Rating GPM (m/hr) 10 7 20 13 30 20 35 50 75 (3) (2) (4.5) (3) (7) (4.5) (8) (11) (17) RPM 1800 1200 1800 1200 1800 1200 1200 1200 1200 Motor Horsepower Required At Rated Speed Pumping 100 SSU Liquid 50 PSI 100 PSI (3.5 BAR) (7 BAR) Maximum Hydrostatic Pressure PSIG (BAR) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28) 400 (28)

The three larger size pumps are equipped with ductile iron pump gears (rotor and idler) and automatic pressure lubrication system. All sizes have O-Ring head and valve gaskets and mechanical seals as standard construction. These pumps are also available with steel externals, see Section 154.
Dimensions for M DriveSee Page 144.9. Performance Data for M DriveSee Pages 144.13 through 144.26.

Maximum Pump Discharge Pressure PSIG (BAR) 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU 100 (7)below 38 SSU 150 (10)38 to 100 SSU 250 (17)above 100 SSU

Maximum Temperature Degrees 225F (107C) 225F (107C) 225F (107C) 225F (107C) 225F (107C) 225F (107C)

Steel Fitted Construction Recommended Above This Viscosity SSU (cSt) 7500 (1619) 7500 (1619)

Approximate Shipping Weight With Valve (Less Power) Pounds (KG) 28 50 50 90 90 95 (13) (22) (22) (41) (41) (43)


1 1 2 1 2 3 5

2 1 3 2 3 5 7

Nominal capacities based on handling thin liquids at 1800 RPM on three small

sizes, 1200 RPM on three large sizes. With special construction, temperatures to + 350F. can be handled with this series.
Metric conversions are based on US measurements and rounded to the nearest whole number.

For viscosities above 15,000 SSU (3,300 cSt), provide details for recommendations. These models have ductile iron rotors; steel fitted rotors not necessary. If suction pressure exceeds 100 PSIG (7 BAR), consult factory.

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

Section Page Issue

144 144.6 B

VIKING HEAVY DUTY PUMPS


SERIES 4195 STANDARD CONSTRUCTION DIMENSIONS

These dimensions are average and not for construction purposes. Certified prints on request.

For specifications, see page 144.2.

DIMENSIONS SERIES 4195 UNMOUNTED PUMPS GGHJHL SIZES

MODEL NO.
GG4195 in mm in mm in mm

A
1

B
2.75 70 3.75 95 3.75 95

D
2.75 70 4.12 105 4.12 105

E
1.62 41 1.75 44 1.75 44

F
1.31 33 2.00 51 2.00 51

G
4.00 102 5.00 127 5.00 127

H
2.44 62 3.50 89 3.50 89

J
.34 9 .41 10 .41 10

K
.94 24 1.50 38 1.50 38

L
.03 1 1.25 32 1.25 32

M
.66 17 .88 22 .88 22

N
1.12 29 1.50 38 1.50 38

O
.31 8 .44 11 .44 11

P
.62 16 .62 16 .62 16

S
7.31 186

T
1.12 29

U
.500 12.70 .750

V
FLAT .19 x .09

W
2.66 67 3.28 83 3.28 83

X
.38 10 .75 19 .75 19

HJ4195

1 1

10.00 1.62 254 41

19.05 4.76 x 2.38 .750 .19 x .09

HL4195

10.00 1.62 254 41

19.05 4.76 x 2.38

For specifications, see page 144.2.

DIMENSIONS SERIES 4195 UNMOUNTED PUMPS ASAKAL SIZES

MODEL NO.
AS4195 in mm in mm in mm

A
2 2

E
2.88 73 2.88 73 2.88 73

F
2.00 51 2.00 51 2.00 51

G
6.75 171 6.75 171 6.75 171

H
4.00 102 4.00 102 4.00 102

J
.41 10 .41 10 .41 10

K
2.25 57 2.25 57 2.25 57

L
1.25 32 1.25 32 1.75 44

M
1.00 25 1.00 25 1.00 25

N
2.00 51 2.00 51 2.50 64

V
.25 x .12

W
7.00 178 7.00 178 7.00 178

Z
1.72 40 1.72 40 1.72 40

5.00 5.25 127 133

.44 1.12 12.12 2.50 1.000 11 29 308 60

.50 1.00 13 25

25.40 6.35 x 3.18 .25 x .12

AK4195

5.00 5.25 127 133

.44 1.12 12.12 2.50 1.000 11 29 308 60

.50 1.00 13 25

25.40 6.35 x 3.18 .25 x .12

AL4195

5.00 5.25 127 133

.44 1.12 12.12 2.50 1.000 11 29 308 60

.50 1.00 13 25

25.40 6.35 x 3.18

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

VIKING HEAVY DUTY PUMPS


SERIES 4195 STANDARD CONSTRUCTION DIMENSIONS

Section Page Issue

144 144.7 B

These dimensions are average and not for construction purposes. Certified prints on request.

For specifications, see page 144.3.

DIMENSIONS SERIES 4195 (D DRIVE) GGHJHL ASAKAL SIZES

MODEL NO. in

B 2.75

D 3.50 89 3.50 89 4.12 114 4.12 114 5.25 133 4.50 114 5.25 133 6.25 159

E 1.50 38 1.50 38 2.12 54 2.94 75 2.94 75 3.69 94 2.94 75 4.00 102

F 20.50 445 20.50 521 20.50 521 29.00 635 29.00 635 29.00 660 29.00 737 39.00 991

H .75 19 .75 19 .75 19 1.00 25 1.00 25 1.00 25 1.00 25 1.38 35

J .75 19 .75 19 .75 19 1.50 38 1.50 38 1.50 38 1.50 38 1.38 35

K 8.50 216 8.50 216 8.50 216 9.00 229 9.00 229 9.00 229 9.00 229 16.00 406

L .38 10 .38 10 0 0 .25 6 .25 6 0 0 0 0 3.75 95

M 3.78 96 3.78 96 4.78 121 4.78 121 4.78 121

M1

N .62 16 .62 16 .62 16 .62 16 .62 16

P .62 13 .62 13 .62 13 .62 14 .62 14 .62 14 .62 14 .62 16

S 4.25 108 4.25 108 4.25 108 4.50 114 4.50 114 4.50 114 4.50 114 8.00 203

1 mm GG4195D in 1 mm in mm HJ4195D HL4195D in mm in mm in mm AS4195D AK4195D AL4195D mm in 3 mm 127 in 2 2 1 1 1 70 2.75 70

3.75 95 3.75 95 3.75 95 5.00 127 5.00 127 5.00

56 frame motors (short base). (Available with GG 143T and 145T frame motors (long base). (Available 56, 143T and 145T frame motors. (Available with HJ 182, 182T, 184, 184T frame motors. (Available with 213, 213T, 215, 215T frame motors. (Available with 254U, 254T, 256U, 256T frame motors. (Available Dimensions includes motor block, base height is 1. Dimension includes motor block, base height is 2 .
NOTE: All AS, AK, AL pump sizes available with any of the three motors shown in columns. with AK through AL size pumps.) HJ through AL size pumps.) HJ through AL size pumps.) or HL size pumps.) with GG size pump.) size pump.)

7.00 178 7.00 178 7.00 178

1.12 29 1.12 29 1.12 29

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

Section Page Issue

144 144.8 B

VIKING HEAVY DUTY PUMPS


SERIES 495 STANDARD CONSTRUCTION DIMENSIONS

These dimensions are average and not for construction purposes. Certified prints on request.

For specifications, see page 144.4.

DIMENSIONS SERIES 495 UNMOUNTED PUMPS GGHJHL SIZES

MODEL NO. in mm in mm in mm

B 2.75 70 3.75 95 3.75 95

C 2.66 67 3.28 83 3.28 83

E 3.00 76 4.75 121 4.75 121

F 4.00 102 5.88 149 5.88 149

G .41 10 .56 14 .56 14

H .50 13 .75 19 .75 19

J 3.44 87 4.50 114 4.50 114

K 2.81 71 4.00 102 4.00 102

N 1.12 29 1.50 38 1.50 38

P .94 24 1.50 38 1.50 38

R 2.875 2.873 73 3.875 3.873 98 3.875 3.873 98

T 1.12 29 1.62 41 1.62 41

U .500 12.70 .750 19.05 .750 19.05

X .62 16 .62 16 .62 16

GG495

FLAT

HJ495

.19 x .09 4.76 x 2.38 .19 x .09 4.76 x 2.38

HL495

For specifications, see page 144.4.

DIMENSIONS SERIES 495 UNMOUNTED PUMPS ASAKAL SIZES

MODEL NO.

AS495 AK495

in

8.38 5.00 213 4.75 6.25 .56 .75

2.00 5.75 51 2.50 121 159 14 19 64 146 22 57 108 308 64 25.40 6.35 x 3.18 178 29 25 40 .75 2.25 4.250 12.12 2.50 1.000 4.248 .25 x .12 7.00 1.12 1.00 1.72

mm AL495 in mm 3

8.88 127 225

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005

VIKING HEAVY DUTY PUMPS


SERIES 495 STANDARD CONSTRUCTION DIMENSIONS

Section Page Issue

144 144.9 B

These dimensions are average and not for construction purposes. Certified prints on request.

For specifications, see page 144.5.

DIMENSIONS SERIES 495 (M DRIVE) GGHJHL SIZES


MODEL NO.
in mm in mm GG495M in mm in mm in mm in mm in mm HJ495M in mm in mm HL495M in mm in mm in mm 95 83 114 16 5 38 1 70 67 87 16 5 29 1 2.75 2.66 3.44 .62 .19 1.12

MOTOR FRAME
56C 143TC 145TC 182TC 184TC 56C 143TC 145TC

E
2.44 62

F
1.50 38 2.00 51 2.50 64 2.25 57 2.75 70 1.50 38 2.00 51 2.50 64 2.25 57 2.75 70 2.75 70 3.50 89

G
2.56 65

K
.34 SLOT 9

3.50 2.75 89 4.50 114 70 3.75 95 2.44 62 3.50 2.75 89 4.50 114 5.25 133 70 3.75 95 4.25 108

8.88 2.88 73 3.38 86 2.56 65 11.12 2.88 73 3.38 86 4.25 108 283 11.81 300 12.56 319 .34 9 .41 10 .41 10 225 9.56 243 .34 9 .41 10 .34 SLOT 9

3.75 3.28 4.50 .62

.19 1.50

182TC 184TC 213TC 215TC

NOTE: Jaw type coupling with straight jaws recommended to facilitate assembly of motor and pump to bracket. COUPLING IS GUARDED WITH PLATES OVER SIDE OPENINGS ON MOUNTING BRACKET.

For specifications, see page 144.5.

DIMENSIONS SERIES 495 (M DRIVE) ASAKAL SIZES


Dimensions are correct for 182TC through 215TC
motors. For 254TC/256TC motors, add .88 to the dimensions shown. NOTE: Jaw type coupling with straight jaws recommended to facilitate assembly of motor and pump to bracket. COUPLING IS GUARDED WITH PLATES OVER SIDE OPENINGS ON MOUNTING BRACKET.

MODEL NO. AS495M AK495M AL495M in mm in mm

A 2

C 19.06

N 2.00

5.00 484 19.56 127 497

6.25

2.75

7.00

5.00

7.00

1.00

.56

8.44

6.38 51 2.50

.50

1.12

7.00

.19

1.00

159

70

178

127

178

25

14

214

162

64

13

29

178

25

VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA

2005