You are on page 1of 164

Prices and

specifications
04/2013
ROTEX Products 2013
22
Heat pump 4
Boiler 36
Flue gas systems 52
Thermal store 96
Solar heating system 110
Heat distribution 124
Installation system 142
Fuel oil tanks 150
Rainwater storage tanks 158
Index
The pricelist is valid from 01/04/2013 to 31/03/2014.
All prices excl. VAT.
Technical changes reserved.
An overview of ROTEX spare parts is available at
www.rotex-heating.com > Service > Spare Parts.
Heat pump HPSU 4
HPSU compact 6
HPSU Bi Bloc 12
HPSU monobloc 16
HPSU
hitemp
20
HybridCube 31
Technical data
HPSU compact HPSU compact H/C Biv 23
HPSU compact HPSU compact H/C 24
G-plus 26
HPSU indoor unit LT Bi-Bloc 26
HPSU outdoor unit LT Bi-Bloc 27
HPSU monobloc 29
HPSU indoor unit /outdoor unit HT Bi-Bloc 30
HP convector 31
HybridCube 35
Boiler 36
A1 oil condensing 36
A1 gas condensing 40
GCU compact 42
Gas condensing wall-mounted boiler GW 48
Flue gas systems 52
Technical data
A1 oil/gas condensing boiler 41
GCU compact 46
Gas condensing wall-mounted boiler GW 50
Thermal store 96
Sanicube / HybridCube 96
Technical data
Sanicube / HybridCube 104
Solar heating system 110
Material combinations 111
Solaris 115
Technical data
Solaris 121
Heat distribution 124
Monopex, System 70 124
Room controller 133
Installation system 142
VA Installation system 142
Fuel oil tanks 150
Variosafe 152
VA-Oil 156
Variosystem / highcube 157
Rainwater storage tanks 158
Variocistern 158
General Business Terms 159
Our offices in Europe 160
3
4
H
e
a
t

p
u
m
p
Heat pump
Overview
ROTEX heat pump HPSU compact H/C Biv HPSU compact H/C
Heat pump for maximum flexibility:
Combination with solar (pressurised solar or drain-
back) and second heat generator
Heat pump for combination with solar
(ROTEX Solaris Drain Back)
SG
Ready
Smart Heat Pumps

Maximum inflow temperature 55 C
New-build applications

Existing building underfloor heating or
Low-temperature radiators (50 C)

Existing buildings with radiators above
50 C

Bivalency option integrated
second heat generator can be
connected

Heating and hot water



Combination with solar
(can also be retro-fitted)

Combination with
second Heat generator
(can also be retro-fitted)

Cooling (Comfort 365)



The components
External unit

Internal unit

Hygienic storage facility with solar
option

Stainless steel storage tank

Standard
not available
The SG Ready label is issued exclusively in Germany. It indicates that the control technology of the
individual heat pump allows incorporation of an intelligent mains power network.
SG
Ready
Smart Heat Pumps
5
H
e
a
t

p
u
m
p
Heat pump
ROTEX heat pump HPSU Bi Bloc HPSU monobloc HPSU
hitemp
Maximum inflow temperature 55 C 80 C
New-build applications

Existing building underfloor heating or


Low-temperature radiators (50 C)

Existing buildings with radiators above


50 C


Bivalency option integrated
second heat generator can be connected

Heating and hot water

Combination with solar
(can also be retro-fitted)
/
Cooling (Comfort 365)

The components
External unit

Internal unit


Hygienic storage facility with solar option

Stainless steel storage tank



Standard

optional when using the HybridCube
not available
4kW 6kW 8kW 11kW 14kW 16kW
HPSU compact 304 H/C Biv & 304 H Biv


HPSU compact 308 H/C Biv & 308 H Biv


HPSU compact 508 H/C Biv & 508 H Biv


HPSU compact 516 H/C Biv & 516 H Biv

HPSU compact 304 H/C & 304 H


HPSU compact 308 H/C& 308 H


HPSU compact 508 H/C & 508 H


HPSU compact 516 H/C & 516 H

HPSU Bi Bloc

HPSU monobloc


HPSU
hitemp



Size available


Size not available
Overview
5
6
Heat pump
H
e
a
t

p
u
m
p
Air-to-water heat pump, HPSU compact
Low Temperature
ROTEX HPSU compact
- Spllt system, conslstlng of outdoor unlt, lndoor unlt wlth lntegrated energy storage tank
- Por hot water and heatlng
- Low Temperature, maxlmum flow temperature 55 C
- Output spectrum 4 to l6 kw
- Output-modulatlng operatlon, lnverter technology
- Content of storage tank 300 or 500 lltres
- |ntegrated solar optlon (Draln-8ack)
- Heatlng and coollng
- |SM (|ntelllgent Storage Management)
- |ntegrated overflow valve
- Smart Grld Peady
- |ntegrated electronlc convenlence controller POTLX PoCon 8l
- Simple and consistent handling for ROTEX A1, GCU compact and HPSU compact
- Clear text display with multi-coloured background lighting for visualisation of status and
error messages
- Intuitive menu guiding
Additional features for Version Biv:
- 8lvalency optlon for lntegratlon of an addltlonal heat source or a pressurlsed solar system (8lv)
SG
Ready
Smart Heat Pumps
L
o
w

T
e
m
p
e
r
a
t
u
r
e
7
Split air -to- water heat pumps up to 55 C flow Type Order No. Price
HPSU compact 304 H/C Biv or 308 H/C Biv
For outdoor units 4 kW, 6 kW, 8 kW (heating and cooling).
Indoor unit with integrated 300 l energy store for hygienic
hot water generation on the instantaneous throughput
principle. Hydraulically equipped with a high-efficiency
pump, diverter valves for hot water / heating and
heating / cooling with integrated return flow temperature
limitation for solar use, integrated overflow, safety module
with electonic pressure gauge and safety valve, flow sensor
and filling and draining cocks. Additional pressurised
heat exchanger for solar applications or external heat
generators. Electrical equipment with load relay and
prepared plug-and-play connection for electric auxiliary
heating / process water heating (9 kW).
This immersion heater should be ordered separately.
Dimensions (B x T x H) 595 x 615 x 1945 mm.
HPSU compact 304 H/C Biv 4 kW
HPSU compact 308 H/C Biv 6 8 kW
14 15 34
14 15 35
3.807,00
4.129,00
HPSU compact 508 H/C Biv or 516 H/C Biv
For outdoor units 6 kW, 8 kW, 11 kW, 14 kW, 16 kW (heating
and cooling). Indoor unit with integrated 500 l energy store
for hygienic hot water generation on the instantaneous
through-flow principle. Hydraulically equipped with a high-
efficiency pump, diverter valves for hot water / heating and
heating / cooling with integrated return flow temperature
limitation for solar use, integrated overflow, safety module
with electonic pressure gauge and safety valve, flow
sensor and filling and draining cocks. Additional pressure
heat exchanger for solar applications or external heat
generators. Electrical equipment with load relay and
prepared plug-and-play connection for electric auxiliary
heating / process water heating (9 kW).
Please order this immersion heater separately.
Dimensions (W x D x H) 790 x 790 x 1951 mm.
HPSU compact 508 H/C Biv 6 8 kW
HPSU compact 516 H/C Biv 11 16 kW
14 15 36
14 15 37
4.769,00
4.999,00
HPSU compact 304 H/C or 308 H/C
For outdoor units 4 kW, 6 kW, 8 kW (heating and cooling).
Indoor unit with integrated 300 l energy store for hygienic
hot water generation on the instantaneous throughput
principle. Hydraulically equipped with a high-efficiency
pump, diverter valves for hot water / heating and
heating / cooling with integrated return flow temperature
limitation for solar use, integrated overflow, safety module
with electonic pressure gauge and safety valve, flow sensor
and filling and draining cocks. Electrical equipment with
load relay and prepared plug-and-play connection for
electric auxiliary heating / process water heating (9 kW).
This immersion heater should be ordered separately.
Dimensions (B x T x H) 595 x 615 x 1945 mm.
HPSU compact 304 H/C 4 kW
HPSU compact 308 H/C 6 8 kW
14 15 30
14 15 31
3.549,00
3.849,00
HPSU compact 508 H/C or 516 H/C
For outdoor units 6 kW, 8 kW, 11 kW, 14 kW, 16 kW (heating
and cooling). Indoor unit with integrated 500 l energy store
for hygienic hot water generation on the instantaneous
through-flow principle. Hydraulically equipped with a high-
efficiency pump, diverter valves for hot water / heating and
heating / cooling with integrated return flow temperature
limitation for solar use, integrated overflow, safety module
with electonic pressure gauge and safety valve, flow sensor
and filling and draining cocks. Electrical equipment with
load relay and prepared plug-and-play connection for
electric auxiliary heating / process water heating (9 kW).
This immersion heater should be ordered separately.
Dimensions (B x T x H) 790 x 790 x 1,951 mm.
HPSU compact 508 H/C 6 8 kW
HPSU compact 516 H/C 11 16 kW
14 15 32
14 15 33
4.459,00
4.679,00
H
e
a
t

p
u
m
p
Heat pump
Air-to-water heat pump, HPSU compact
Low Temperature
L
o
w

T
e
m
p
e
r
a
t
u
r
e
7
8
Heat pump
H
e
a
t

p
u
m
p
Air-to-water heat pump, HPSU compact
Low Temperature
L
o
w

T
e
m
p
e
r
a
t
u
r
e
Split air -to- water heat pumps up to 55 C flow Type Order No. Price
HPSU compact 304 H Biv or 308 H Biv
For outdoor units 4 kW, 6 kW, 8 kW (heating). Indoor unit
with integrated 300 l energy store for hygienic hot water
generation on the instantaneous throughput principle.
Hydraulically equipped with a high-efficiency pump,
diverter valves for hot water / heating and heating with
integrated return flow temperature limitation for solar
use, integrated overflow, safety module with electonic
pressure gauge and safety valve, flow sensor and filling and
draining cocks. Additional pressurised heat exchanger for
solar applications or external heat generators. Electrical
equipment with load relay and prepared plug-and-play
connection for electric auxiliary heating / process water
heating (9 kW).
This immersion heater should be ordered separately.
Dimensions (B x T x H) 595 x 615 x 1945 mm.
HPSU compact 304 H Biv 4 kW
HPSU compact 308 H Biv 6-8 kW
14 15 42
14 15 43
3.757,00
4.079,00
HPSU compact 508 H Biv or 516 H Biv
For outdoor units 6 kW, 8 kW, 11 kW, 14 kW, 16 kW (heating).
Indoor unit with integrated 500 l energy store for hygienic
hot water generation on the instantaneous through-flow
principle. Hydraulically equipped with a high-efficiency
pump, diverter valves for hot water / heating and heating
with integrated return flow temperature limitation for solar
use, integrated overflow, safety module with electonic
pressure gauge and safety valve, flow sensor and filling
and draining cocks. Additional pressure heat exchanger
for solar applications or external heat generators. Electrical
equipment with load relay and prepared plug-and-play
connection for electric auxiliary heating / process water
heating (9 kW).
Please order this immersion heater separately.
Dimensions (W x D x H) 790 x 790 x 1951 mm.
HPSU compact 508 H Biv 6 8 kW
HPSU compact 516 H Biv 11 16 kW
14 15 44
14 15 45
4.719,00
4.949,00
HPSU compact 304 H or 308 H
For outdoor units 4 kW, 6 kW, 8 kW (heating). Indoor unit
with integrated 300 l energy store for hygienic hot water
generation on the instantaneous throughput principle.
Hydraulically equipped with a high-efficiency pump,
diverter valves for hot water / heating and heating with
integrated return flow temperature limitation for solar
use, integrated overflow, safety module with electonic
pressure gauge and safety valve, flow sensor and filling and
draining cocks. Electrical equipment with load relay and
prepared plug-and-play connection for electric auxiliary
heating / process water heating (9 kW). This immersion
heater should be ordered separately. Dimensions (B x T x H)
595 x 615 x 1945 mm.
HPSU compact 304 H 4 kW
HPSU compact 308 H 6 8 kW
14 15 39
14 15 40
3.499,00
3.799,00
HPSU compact 508 H or 516 H
For outdoor units 6 kW, 8 kW, 11 kW, 14 kW, 16 kW (heating).
Indoor unit with integrated 500 l energy store for hygienic
hot water generation on the instantaneous through-flow
principle. Hydraulically equipped with a high-efficiency
pump, diverter valves for hot water / heating and heating
with integrated return flow temperature limitation for solar
use, integrated overflow, safety module with electonic
pressure gauge and safety valve, flow sensor and filling and
draining cocks. Electrical equipment with load relay and
prepared plug-and-play connection for electric auxiliary
heating / process water heating (9 kW).
This immersion heater should be ordered separately.
Dimensions (B x T x H) 790 x 790 x 1,951 mm.
HPSU compact 508 H 6 18 kW
HPSU compact 516 H 11 16 kW
14 15 41
14 15 38
4.409,00
4.629,00
9
H
e
a
t

p
u
m
p
Heat pump
L
o
w

T
e
m
p
e
r
a
t
u
r
e
Regulation accessories Type Order No. Price
Room controller
Convenience controller with wall-mounting for use as
a) A remote control (external equipment controller)
b) Mixer unit (additional or standalone)
c) Room thermostat for heat exchanger
RoCon U1 15 70 34 159,00
Option 1: Cabled room thermostat


Option 2: Wireless Room Thermostat
RKRTW
RKRTR
14 10 03
14 10 04
149,00
289,00
Mixer module
Controller for mixer valve with speed-controlled
high-efficiency pump including mixer circuit sensor
a) in combination with an equipment controller (RoCon B1).
Mixer parameters adjustable via the heat generator.
b) in combination with room controller (RoCon U1)
1. can be used as a standalone solution
2. can be integrated in the system via BUS
RoCon M1 15 70 68 169,00
Outdoor sensor for RoCon convenience regulation RoCon OT1 15 60 70 29,00
Backup heater
Additional heating for HSPU compact.
Electric immersion heater 3 x 230 V 50 Hz / 9000 Watt to support
the heat pump as a back-up and booster heater. 1000mm long.
Plug-and-play installation, ready to plug in.
BU9c 14 10 28 410,00
G-plus
Wall-mounted gas condensing unit, room-air independent.
3.5 - 15 kW to support the HPSU compact heat pump.
Instead of the electrical auxiliary heating, the condensing unit
can be used as a backup and booster heater. Actuation is by the
intelligent HPSU compact controller. ROTEX G-plus is supplied ready
for connection, with integrated circulation pump, automatic vent and
installation kit. The connection kit G-plus (Item No. 16 01 28) is available
for the connection of the condensing unit to the HSPU compact.
Dimensions (W x D x H) 340 x 340 x 640 mm; weight 25 kg.
G-plus 14 07 00 1.654,00
G-plus storage tank connection
(storage tank return connection and electric immersion heater
connection)
Kit for connecting the G-plus gas condensing unit to the HSPU compact.
Consists of: piping, fittings, storage tank incorporation, Communication
line and double-wall reducer 80 / 60 cm. Unpressurised mode.
SAG-plus 16 01 28 210,00
Storage tank incorporation heat exchanger Variant 2
(storage tank return connection and electric immersion heater
connection)
Kit for connecting a wood-burning, pellet, oil or gas boiler the
HSPUcompact or a ROTEX storage tank (compatible for all models
from 2013) as an alternative to an immersion heater. Consists of:
piping, fittings, storage tank incorporation and circulation pump. For
the connection of a boiler to the unpressurised area, you will need an
additional plate heat exchanger (e.g. ROTEX RPWT1 Order No. 16 20 31).
This variant can only be realised with controllable heat generators.
SAK 16 01 27 263,00
Boiler incorporation A1
(storage tank return connection and electric immersion heater
connection)
Kit for connecting of a ROTEX A1 condensing boiler for bivalent
operation with an HPSU compact. Consists of: piping, fittings,
storage tank incorporation. Unpressurised mode.
SAA1 16 01 25 144,00
Air-to-water heat pump, HPSU compact
Low Temperature
9
10
Heat pump
H
e
a
t

p
u
m
p
L
o
w

T
e
m
p
e
r
a
t
u
r
e
Article Type Order No. Price
Hydraulic diverter DN 125 for HSPU compact,
HPSU Bi-Bloc and HPSU
hitemp
Consisting of DN125 round pipe sub-divided into four zones
(using perforated separator discs, length approx. 1550 mm), equipped
with 8 x heating circuit connections 1 male thread, and a 1 x sleeve
and standing foot. Max. permissible operating pressure: 6 bar, max.
permissible temperature: 110 C.
HWC 17 29 00 489,00
Thermal insulation for hydraulic diverter
Thermal insulation in accordance with EnEV, consisting of 60 mm PUR
foam in a sheet steel casing.
WHWC 17 29 01 309,00
Mixer group for all ROTEX heat generators
For a mixed heating circuit.
Ready to plug in, in the thermal insulation case, with pressure controlled
high-efficiency circulation pump, motor mixer, stops valves and
temperature displays.
MK1 15 60 67 799,00
Mixer group for all ROTEX heat generators
For a mixed heating circuit.
Ready to plug in, in the thermal insulation case, with PWM-controlled
high-efficiency circulation pump, motor mixer, stops valves and
temperature displays. (Available from June 2013)
MK2 15 60 72 799,00
Fittings kit for mixer group MK
1 female thread x 1 1 / 2 flat-sealing.
VMK1 15 60 53 21,00
Sludge and magnetic separator
Compact sludge separator with drain cock and thermal insulation.
Input G1-IG (union nut), outlet G1-lG.
SAS1 15 60 21 199,00
Burner blocking contact connection cable
For RPS2, RPS3, RPS3 M, RPS3 25 M.
BSKK 16 41 10 16,80
Air-to-water heat pump, HPSU compact
Low Temperature
11
H
e
a
t

p
u
m
p
Heat pump
L
o
w

T
e
m
p
e
r
a
t
u
r
e
11
12
Air-to-water heat pump, HPSU Bi-Bloc
Low Temperature
ROTEX HPSU Bi-Bloc
- Spllt system conslstlng of external unlt and lnternal unlt
- Por hot water, heatlng and coollng
- Low Temperature, maxlmum flow temperature 55 C
- Output spectrum 6 to l6 kw
- Output-modulatlng operatlon, lnverter technology
- Por comblnatlon wlth the energy store POTLX HybrldCube see page 3l
- Can be selected wlth solar optlon ln comblnatlon wlth POTLX HybrldCube
H
e
a
t

p
u
m
p
Heat pump
EU Environ-
mental Label
for HPSU in
combination
with under-
floor heating
L
o
w

T
e
m
p
e
r
a
t
u
r
e
13
Air-to-water heat pump, HPSU Bi-Bloc
Low Temperature
H
e
a
t

p
u
m
p
Heat pump
Accessories Type Order No. Price
Option 1: Cabled room thermostat
Option 2: Wireless Room Thermostat
RKRTW
RKRTR
14 10 03
14 10 04
149,00
289,00
Screed temperature sensor EKRTETS 14 10 36 29,00
E-Pac LT switching unit
Switching unit for mounting on the HybridCube energy storage
unit (300 l, 500 l). Includes three-way switching valve, connection
cable and storage tank sensor. Required for connecting the
HybridCube energy storage unit to the HPSU. Please order the
immersion heater separately if you want additional heating
output.
EP LT 3H (for 300 L HYC, HPSU heating/heating and cooling)
EP LT 5H (for 500 l HYC, HPSU only heating)
EP LT 5X (for 500 L HYC, HPSU heating and cooling)
DVCPLT3H / X
DVCPLT5H
DVCPLT5X
14 10 62
14 10 60
14 10 61
259,00
459,00
609,00
Storage tank sensor for HPSU LT Bi-Bloc
For use if no E-Pac is being used and the heat pump is directly
connected to the storage tank (by customer).
SF LT 14 10 37 42,00
Booster heater supplementary heating for HPSU Bi-Bloc in
combination with HybridCube
Electric immersion heater 230 V-50 Hz / 3000 Watt to support the
heat pumps as a booster heater. 900 mm long.
BO3S 16 51 37 299,00
Split air -to- water heat pumps up to 55 C flow Type Order No. Price
ROTEX HPSU Bi-Bloc Internal Unit
For external unit 4 16 kW. Hydraulically equipped with
high-efficiency pump, expansion vessel, safety module with
pressure gauge and safety valve, flow monitor and filling and
evacuation valves and brass dirt trap. Electrical equipment with
load contactors for 3/6/9 kW auxiliary electric heating and heat
circulating pump.
Dimensions (W x D x H) 502 x 361 x 922 mm.
Heating only:
HPSU 4 kW internal unit with 3 kW electric immersion heater
1~230 V for 4 kW external unit.
HPSU 8 kW internal unit with 9 kW electric immersion heater
3~400 V for 6 8 kW external unit.
HPSU 16 kW internal unit with 9 kW electric immersion heater
3~400 V for 11 16 kW external unit.
Heating and cooling:
HPSU 4 kW internal unit with 3 kW electric immersion heater
1~230 V for 4 kW external unit.
HPSU 8 kW internal unit with 9 kW electric immersion heater
3~400 V for 6 8 kW external unit.
HPSU 16 kW internal unit with 9 kW electric immersion heater
3~400 V for 11 16 kW external unit.
RHBH04CA3V
RHBH08CA9W
RHBH16CA9W
RHBX04CA3V
RHBX08CA9W
RHBX16CA9W
14 41 70
14 41 71
14 41 76
14 41 72
14 41 73
14 41 75
2.479,00
2.799,00
3.019,00
2.729,00
3.059,00
3.309,00
L
o
w

T
e
m
p
e
r
a
t
u
r
e
13
14
H
e
a
t

p
u
m
p
Heat pump
Air-to-water heat pump, HPSU Bi-Bloc
Low Temperature
Accessories Type Order No. Price
SOL-PAC LT/HT
Communication unit between the ROTEX HPSU Bi-Bloc / HPSU
Monobloc / HPSU
hitemp
and ROTEX Solaris. Consisting of connecting cable
and circuit board.
Supplementary package SOLARIS Sol-Pac SOL-PAC LT/HT 14 05 38 149,00
Burner blocking contact connection cable
For RPS2, RPS3, RPS3 M, RPS3 25 M.
BSKK 16 41 10 16,80
Condensate pan for Internal Unit EKHBDPCA2 14 05 40 169,00
Return flow temperature limitation
Thermal return flow temperature limitation to max. 55 C.
Component required for connecting a solar system to the HPSU.
Choice depends on pipework design and flow rates.
RLB 300 with 1 male thread and Kvs 3.2 (only 6 8 kW HPSU)
RLB 500 with 1 1 / 4 male thread and Kvs 9 (6 16 kW HPSU)
RLB 300
RLB 500
14 01 14
14 01 15
108,00
124,00
3-way switch valve
3-way switch valve 1 male thread with motor drive 240 V, switching
time 6 sec. including connection cable 2 m.
3-W SV 15 60 34 115,00
Supplementary user interface for HPSU Bi-Bloc indoor unit
For direct operation at the unit, if the heat pump
controller (REMOCON) is used as a room thermostat
EKRUCAL1 14 10 44 129,00
Interface cable for configuration of the heat pump controller
Via PC, for HPSU Bi-Bloc
RKPCCAB1 14 05 42 239,00
Decentalised outdoor temperature sensor RKRSCA1 14 10 39 83,00
Overflow valve
Overflow valve DN 20 or DN 25 with fitting with angle body.
Necessary component of an HPSU heat pump system excluding
HPSUcompact, in order to the minimum flow rate on the internal unit.
UESV 20
UESV 25
14 01 11
14 01 16
82,00
109,00
Hydraulic diverter DN 125 for HSPU compact,
HPSU Bi-Bloc and HPSU
hitemp
Consisting of DN125 round pipe sub-divided into four zones
(using perforated separator discs, length approx. 1550 mm), equipped
with 8 x heating circuit connections 1 male thread, and a 1 x sleeve
and standing foot. Max. permissible operating pressure: 6 bar, max.
permissible temperature: 110 C.
HWC 17 29 00 489,00
Thermal insulation for hydraulic diverter
Thermal insulation in accordance with EnEV, consisting of 60 mm PUR
foam in a galvanised sheet steel casing.
WHWC 17 29 01 309,00
Sludge and magnetic separator
Compact sludge separator with drain cock and thermal insulation.
Input G1-IG (union nut), outlet G1-lG.
SAS 1 15 60 21 199,00
L
o
w

T
e
m
p
e
r
a
t
u
r
e
15
H
e
a
t

p
u
m
p
Heat pump
External unit Low Temperature
Air-to-water heat pump, HPSU compact and HPSU Bi-Bloc
Split air -to- water heat pumps up to 55 C flow Type Order No. Price
ROTEX HPSU compact / HPSU Bi-Bloc External unit 4 8 kW
(Heating and cooling)
Inverter split heat pump external unit as an inverter-controlled
compressor- / evaporator unit with extended modulation range.
Accommodated in a weatherproof, galvanized sheet steel housing,
primed, synthetic resin and powder coated.
Application range: Heating to -25 C external temperature.
Dimensions (B x T x H) 825 x 300 x 735 mm.
HPSU Bi-Bloc 4 kW External unit 1~230 V
HPSU Bi-Bloc 6 kW External unit 1~230 V
HPSU Bi-Bloc 8 kW External unit 1~230 V
RRLQ004CAV3
RRLQ006CAV3
RRLQ008CAV3
14 51 51
14 51 52
14 51 53
1.520,00
1.596,00
2.389,00
ROTEX HPSU compact / HPSU Bi-Bloc External unit 11 16 kW
(Heating and cooling)
Inverter split heat pump external unit as an inverter-controlled
compressor- / evaporator unit with extended modulation range.
Accommodated in a weatherproof, galvanized sheet steel housing,
primed and synthetic resin and powder coated. Application range
heating to -25 C external temperature.
Dimensions (B x T x H) 900 x 320 x 1,345 mm.
HPSU Bi-Bloc 11 kW external unit 3~400 V
HPSU Bi-Bloc 14 kW external unit 3~400 V
HPSU Bi-Bloc 16 kW external unit 3~400 V
HPSU Bi-Bloc 11 kW external unit 1~230 V
HPSU Bi-Bloc 14 kW external unit 1~230 V
HPSU Bi-Bloc 16 kW external unit 1~230 V
RRLQ011CAW1
RRLQ014CAW1
RRLQ016CAW1
RRLQ011CAV3
RRLQ014CAV3
RRLQ016CAV3
14 51 48
14 51 49
14 51 50
14 51 45
14 51 46
14 51 47
3.999,00
4.449,00
4.889,00
3.649,00
3.999,00
4.399,00
Accessories Type Order No. Price
Wall bracket
Wall bracket for mounting the external unit,
including rubber buffer for noise de-coupling.
Wall bracket for 4 8 kW external unit
Wall bracket for 11 16 kW external unit
WKS 1
WKS 2
14 05 05
14 05 28
108,00
169,00
Standing bracket
Optional, for external units 11 16 kW
Dimensions (B x T x H) 120 x 64 x 30 cm
Weight 25 kg.
SKS 14 05 32 420,00
Mounting feet, optional, for external units 4 8 kW,
Height 10 cm recommended for socket and wall bracket mounting
EKFT008CA 14 05 41 119,00
Drain pan for 4 8 kW external unit
With central drain for collecting and removal of the melt water.
EKDP008CA 14 05 33 159,00
Heater for drain pan trough for 4 8 kW external unit EKDPH008CA 14 05 34 239,00
Article Size VPE Order No. Price
Coolant line copper tharmally insulated. The thermal insulation of the coolant line
meets Euro Class E (fire behaviour / material class) in accordance with DIN EN 13501-1.
Copper thermally insulated
Copper thermally insulated
Copper thermally insulated
Copper thermally insulated
Copper thermally insulated
Copper thermally insulated
1 / 4
1 / 4
3 / 8
3 / 8
5 / 8
5 / 8
12 m
25 m
12 m
25 m
12 m
25 m
14 31 33
14 31 39
14 31 34
14 31 40
14 31 35
14 31 41
94,00
139,00
134,00
199,00
192,00
339,00
L
o
w

T
e
m
p
e
r
a
t
u
r
e
15
16
Heat pump Heat pump
Air-to-water heat pump, HPSU monobloc
Low Temperature
ROTEX HPSU monobloc
- Solo unlt for lnstallatlon outdoors (lnstallatlon wlthout coolant llne)
- Por hot water and heatlng
- Low Temperature, maxlmum flow temperature 55 C
- Output spectrum ll to l6 kw
- Output-modulatlng operatlon, lnverter technology
- Por comblnatlon wlth the energy store POTLX HybrldCube see page 3l
- Can be selected wlth solar optlon ln comblnatlon wlth POTLX HybrldCube
- Heatlng and coollng
H
e
a
t

p
u
m
p
L
o
w

T
e
m
p
e
r
a
t
u
r
e
17
Heat pump
Air-to-water heat pump, HPSU monobloc
Low Temperature
Heat pump
H
e
a
t

p
u
m
p
L
o
w

T
e
m
p
e
r
a
t
u
r
e
Air -to- water heat pumps monobloc up to 55 C flow Type Order No. Price
ROTEX HPSU monobloc
Heating and cooling
HPSU monobloc 11 kW X 3~400 V
HPSU monobloc 16 kW X 3~400 V
HPSU monobloc 11 kW X 1~230 V
HPSU monobloc 16 kW X 1~230 V
RBLQ011AA6W1
RBLQ016AA6W1
RBLQ011AA6V3
RBLQ016AA6V3
14 31 76
14 31 78
14 31 73
14 31 75
7.649,00
8.599,00
7.085,00
7.850,00
Accessories Type Order No. Price
Option 1: Cabled room thermostat
Option 2: Wireless Room Thermostat
RKRTW
RKRTR
14 10 03
14 10 04
149,00
289,00
Screed temperature sensor EKRTETS 14 10 36 29,00
E-Pac LT switching unit
Switching unit for mounting on the HybridCube energy storage
unit (300 l, 500 l). Includes three-way switching valve, connection
cable and storage tank sensor. Required for connecting the
HybridCube energy storage unit to the HPSU. Please order the
immersion heater separately if you want additional heating
output.
EP LT 3H (for 300 L HYC, HPSU heating/heating and cooling)
EP LT 5X (for 500 L HYC, HPSU heating and cooling)
DVCPLT3H / X
DVCPLT5X
14 10 62
14 10 61
259,00
609,00
SOL-PAC LT/HT
Communication unit between the ROTEX HPSU Bi-Bloc / HPSU
Monobloc / HPSU
hitemp
and ROTEX Solaris. Consisting of
connecting cable and circuit board.
Supplementary package SOLARIS Sol-Pac SOL-PAC LT/HT 14 05 38 149,00
Connection cable for burner blocking contact
for RPS2, RPS3, RPS3 M, RPS3 25 M
BSKK 16 41 10 16,80
Return flow temperature limitation
Thermal return flow temperature limitation to max 55 C.
Component required for connecting a solar system to the HPSU.
Choice depends on pipework design and flow rates.
RLB 300 with 1 male thread and Kvs 3.2 (only 6 8 kW HPSU)
RLB 500 with 1 1 / 4 male thread and Kvs 9 (6 16 kW HPSU).
RLB 300
RLB 500
14 01 14
14 01 15
108,00
124,00
3-way switch valve
Three-way swithc valve 1" male thread with motor drive 240 V,
Switch time 6 seconds, including 2 m connection cable.
3-W SV 15 60 34 115,00
17
18
H
e
a
t

p
u
m
p
Heat pump
Air-to-water heat pump, HPSU monobloc
Low Temperature
Article Type Order No. Price
Overflow valve
Overflow valve DN 25 with screw fitting in angle body.
Necessary component of an HPSU heat pump system excluding
HPSUcompact, in order to the minimum flow rate
on the internal unit.
UESV 25 14 01 16 109,00
Hydraulic diverter DN 125 for HSPU compact,
HPSU Bi-Bloc and HPSU
hitemp

Consisting of DN125 round pipe sub-divided into four zones
(using perforated separator discs, length approx. 1550 mm), equipped
with 8 x heating circuit connections 1 male thread, and a 1 x sleeve
and standing foot.
Max. permissible operating pressure: 6 bar, max. permissible tempera-
ture: 110 C.
HWC 17 29 00 489,00
Thermal insulation for hydraulic diverter
Thermal insulation in accordance with EnEV, consisting of 60 mm PUR
foam in a sheet steel casing.
WHWC 17 29 01 309,00
Sludge and magnetic separator
Compact sludge separator with drain cock and thermal insulation.
Input G1-IG (union nut), outlet G1-lG.
SAS 1 15 60 21 199,00
L
o
w

T
e
m
p
e
r
a
t
u
r
e
19
H
e
a
t

p
u
m
p
Heat pump
19
20
Heat pump
Air-to-water heat pump, HPSU
hitemp
High Temperature
ROTEX HPSU
hitemp

- Spllt system conslstlng of external unlt and lnternal unlt
- Por hot water and heatlng
- Hlgh Temperature, maxlmum flow temperature 80 C
- Output spectrum ll to l6 kw
- Output-modulatlng operatlon, lnverter technology
- Por comblnatlon wlth the energy storage unlt POTLX HybrldCube see page 3l or a stalnless steel storage tank see page 33
- Can be selected wlth solar optlon ln comblnatlon wlth POTLX HybrldCube
H
e
a
t

p
u
m
p
H
i
g
h

T
e
m
p
e
r
a
t
u
r
e
21
Heat pump
Air-to-water heat pump, HPSU
hitemp
High Temperature
H
e
a
t

p
u
m
p
Split air -to- water heat pumps up to 80 C flow Type Order No. Price
ROTEX HPSU
hitemp
Internal unit
For external unit 11, 14 and 16 kW (Heating)
Heating of internal unit. Hydraulically equipped with speed-
controlled heating circulation pump, expansion vessel, safety
module with pressure gauge and safety valve, filling and
evacuation valves and brass dirt trap.
Including external control unit which can also be used as a room
thermostat. Dimensions (W x D x H) 600 x 695 x 705 mm.
HPSU
hitemp
11 kW internal unit 3~400V
HPSU
hitemp
14 kW internal unit 3~400V
HPSU
hitemp
16 kW internal unit 3~400V
HPSU
hitemp
11 kW internal unit 1~230V
HPSU
hitemp
14 kW internal unit 1~230V
HPSU
hitemp
16 kW internal unit 1~230V
RKHBRD011ABY1
RKHBRD014ABY1
RKHBRD016ABY1
RKHBRD011ABV1
RKHBRD014ABV1
RKHBRD016ABV1
14 31 88
14 31 89
14 31 90
14 31 85
14 31 86
14 31 87
4.820,00
4.965,00
5.115,00
4.630,00
4.770,00
4.915,00
Accessories Type Order No. Price
Backup heater HPSU
hitemp
Supplementary heating
Electric supplementary heating with 230/400 V-50 Hz / 6000 Watt
for HPSU
hitemp
for wall-mounting. Comprises backup heater with
flow monitor, bleeder valve, overcurrent protection and cable
bushing. For connection to the HPSU
hitemp
you will need the
communication board RKRP1AHT.
1-phase connection
3-phase connection
RKBUHAA6V3
RKBUHAA6W1
14 10 26
10 10 27
806,00
806,00
Communication board
Required for the connection of max. 2 additional room
thermostats (RKRTRW) or max. 2 additional self-contained mixer
units.
RKRP1AHT 14 10 11 159,00
Supplementary user interface
For direct operation at the unit, if the heat pump
controller (REMOCON) is used as a room thermostat.
RKRUAHT 14 10 10 222,00
E-Pac HT switching unit
Switching unit for mounting on the HybridCube energy storage
unit (300 / 500 l). Includes three-way switch valve, connection
cable and storage tank sensor. Required for connecting the
HybridCube energy storage unit to the HPSU
hitemp
.
EP HT 3H (for 300 l HYC)
EP HT 5H (for 500 l HYC)
EP HT 3H
EP HT 5H
14 10 46
14 10 45
239,00
429,00
SOL-PAC LT/HT
Communication unit between the ROTEX HPSU Bi-Bloc / HPSU
Monobloc / HPSU
hitemp
and ROTEX Solaris. Consisting of connect-
ing cable and circuit board.
Supplementary package SOLARIS Sol-Pac SOL-PAC LT/HT 14 05 38 149,00
Burner blocking contact connection cable
For RPS2, RPS3, EPS3 M, RPS3 25 M.
BSKK 16 41 10 16,80
3-way switch valve
Three-way swithc valve 1" male thread with motor drive 240 V,
Switch time 6 seconds, including 2 m connection cable.
3-W SV 15 60 34 115,00
H
i
g
h

T
e
m
p
e
r
a
t
u
r
e
21
22
Heat pump
H
e
a
t

p
u
m
p
Split air -to- water heat pumps up to 80 C flow Type Order No. Price
ROTEX HPSU
hitemp
External unit (Heating)
Inverter split heat pump external unit as an inverter-controlled
compressor / condenser unit. Accommodated in a weatherproof,
galvanized sheet steel housing, primed and synthetic resin and
powder coated. Application for high temperatures up to 80 C
without electrical heating. Operation of the appliance down to -25 C.
Dimensions (W x D x H) 900 x 320 x 1,345 mm.
HPSU hitemp 11 kW external unit 3~400 V
HPSU hitemp 14 kW external unit 3~400 V
HPSU hitemp 16 kW external unit 3~400 V
HPSU hitemp 11 kW external unit 1~230 V
HPSU hitemp 14 kW external unit 1~230 V
HPSU hitemp 16 kW external unit 1~230 V
RRRQ011AAY1
RRRQ014AAY1
RRRQ016AAY1
RRRQ011AAV1
RRRQ014AAV1
RRRQ016AAV1
14 31 82
14 31 83
14 31 84
14 31 79
14 31 80
14 31 81
4.010,00
4.465,00
4.885,00
3.665,00
4.015,00
4.395,00
Accessories air -to- water heat pumps up to 80 C flow Type Order No. Price
Wall bracket
Wall bracket for mounting the external unit, including rubber buffer
for noise de-coupling. Wall bracket external units 11 16 kW.
WKS 2 14 05 28 169,00
Standing bracket
Optional, for external units 11 16 kW
Dimensions (B x T x H) 120 x 64 x 30 cm
Weight 25 kg
SKS 14 05 32 420,00
Air-to-water heat pump, HPSU
hitemp
High Temperature
H
i
g
h

T
e
m
p
e
r
a
t
u
r
e
Accessories Type Order No. Price
Hydraulic diverter DN 125 for HSPU compact,
HPSU Bi-Bloc and HPSU
hitemp

Consisting of DN125 round pipe sub-divided into four zones
(using perforated separator discs, length approx. 1550 mm),
equipped with 8 x heating circuit connections 1 male thread,
and a 1 x sleeve and standing foot. Max. permissible operating
pressure: 6 bar, max. permissible temperature: 110 C.
HWC 17 29 00 489,00
Thermal insulation for hydraulic diverter
Thermal insulation in accordance with EnEV, consisting of 60 mm
PUR foam in a galvanised sheet steel casing.
WHWC 17 29 01 309,00
Sludge and magnetic separator
Compact sludge separator with drain cock and thermal insulation.
Input G1-IG (union nut), outlet G1-lG.
SAS 1 15 60 21 199,00
23
Heat pump
H
e
a
t

p
u
m
p
HPSU compact (Internal unit) HPSU compact H/C Biv (HPSU compact H Biv)
HPSU compact 304
4 kW
HPSU compact 308
6 8 kW
HPSU compact 508
6 8 kW
HPSU compact 516
11 16 kW
14 15 34 (14 15 42) 14 15 35 (14 15 43) 14 15 36 (14 15 44) 14 15 37 (14 15 45)
Basic data
Dimensions (W x D x H) mm 595 x 615 x 1945 595 x 615 x 1945 790 x 790 x 1951 790 x 790 x 1951
Unit weight kg 92 92 119 121
Operational range flow temperature (Heating) C Min: 15 / Max: 55 Min: 15 / Max: 55 Min: 15 / Max: 55 Min: 15 / Max: 55
Operational range flow temperature (Cooling)
1)
C Min: 5 / Max: 22 Min: 5 / Max: 22 Min: 5 / Max: 22 Min: 5 / Max: 22
Operational range DHW (with EHS) C Min: 25 / Max: 80 Min: 25 / Max: 80 Min: 25 / Max: 80 Min: 25 / Max: 80
Connection refrigerant line
Gas lines

(mm) 5 / 8 (15,9) 5 / 8 (15,9) 5 / 8 (15,9) 5 / 8 (15,9)


Liquid line

(mm) 1 / 4 (6,4) 1 / 4 (6,4) 1 / 4 (6,4) 3 / 8 (9,5)


Storage tank data
Total storage capacity Litres 300 300 500 500
Max. permissible storage water temperature C 85 85 85 85
Heat consumption at readiness and at 60 C kWh / 24 h 1,3 1,3 1,4 1,4
Drinking water heating
Drinking water capacity Litres 27,8 27,8 29 29
Maximum operating pressure bar 6 6 6 6
Material of
domestic hot water heat exchanger
stainless steel stainless steel stainless steel stainless steel
Drinking water heat exchanger surface m 5,8 5,8 6 6
Storage tank charging / discharging heat exchanger (stainless steel)
Water capacity heat exchanger Litres 13,2 13,2 12,1 17,4
Surface of charging heat exchanger m 2,7 2,7 2,5 3,5
Pressurised solar heat exchanger (stainless steel)
Water capacity heat exchanger Litres 4,2 4,2 12,5 12,5
Surface of charging heat exchanger m 0,8 0,8 1,7 1,7
Thermal output data
Hot water volume without reheating
at 8 l / min / 12 l / min draw-off rate
(TKW = 10 C / TWW = 40 C / TSP = 50 C)*
Litres 184 / 153 184/153 324 / 282
(288 / 240)**
324 / 282
(288 / 240)**
Hot water volume without reheating
at 8 l / min / 12 l / min draw-off rate
(TKW = 10 C / TWW = 40 C / TSP = 60 C)*
Litres 282 / 252 282 / 252 492 / 444 492 / 444
Hot water volume without reheating
at 8 l / min / 12 l / min draw-off rate
(TKW = 10 C / TWW = 40 C / TSP = 65 C)*
Litres 352 / 321 352 / 321 560 / 516 560 / 516
Reheating time draw-off volume
140 l -> 5820 Wh (bath draw off)
Min. 90 45 45 25
Reheating time draw-off volume
90 l -> 3660 Wh (shower draw off)
Min. 55 30 30 17
Pipe connections
Cold and hot water Inch 1" male thread 1" male thread 1" male thread 1" male thread
Heating inflow and return flow Inch 1" female thread 1" female thread 1" female thread 1" female thread
Technical data
air-to-water heat pump, HPSU compact
Low Temperature
* with storage tank heat exchanger completely charged, ** Storage tank only charged with heat pump without immersion heater
Reheating time = The time needed to reheat the thermal store after a certain quantity of DHW has been discharged to a store temperature of 50 C
1) Only for devices heating and cooling
L
o
w

T
e
m
p
e
r
a
t
u
r
e
23
24
H
e
a
t

p
u
m
p
Heat pump
HPSU compact (Internal unit) HPSU compact H/C (HPSU compact H)
HPSU compact 304
4 kW
HPSU compact 308
6 8 kW
HPSU compact 508
6 8 kW
HPSU compact 516
11 16 kW
14 15 30 (14 15 39) 14 15 31 (14 15 40) 14 15 32 (14 15 41) 14 15 33 (14 15 38)
Basic data
Dimensions (W x D x H) mm 595 x 615 x 1945 595 x 615 x 1945 790 x 790 x 1951 790 x 790 x 1951
Unit weight kg 87 87 114 116
Operational range flow temperature (Heating) C Min: 15 / Max: 55 Min: 15 / Max: 55 Min: 15 / Max: 55 Min: 15 / Max: 55
Operational range flow temperature (Cooling)
1)
C Min: 5 / Max: 22 Min: 5 / Max: 22 Min: 5 / Max: 22 Min: 5 / Max: 22
Operational range DHW (with EHS) C Min: 25 / Max: 80 Min: 25 / Max: 80 Min: 25 / Max: 80 Min: 25 / Max: 80
Connection refrigerant line
Gas lines

(mm) 5 / 8 (15,9) 5 / 8 (15,9) 5 / 8 (15,9) 5 / 8 (15,9)


Liquid line

(mm) 1 / 4 (6,4) 1 / 4 (6,4) 1 / 4 (6,4) 3 / 8 (9,5)


Storage tank data
Total storage capacity Litres 300 300 500 500
Max. permissible storage water temperature C 85 85 85 85
Heat consumption at readiness and at 60 C kWh / 24 h 1,3 1,3 1,4 1,4
Drinking water heating
Drinking water capacity Litres 27,8 27,8 29 29
Maximum operating pressure bar 6 6 6 6
Material of
domestic hot water heat exchanger
stainless steel stainless steel stainless steel stainless steel
Drinking water heat exchanger surface m 5,8 5,8 6 6
Storage tank charging / discharging heat exchanger (stainless steel)
Water capacity heat exchanger Litres 13,2 13,2 12,1 17,4
Surface of charging heat exchanger m 2,7 2,7 2,5 3,5
Pressurised solar heat exchanger (stainless steel)
Water capacity heat exchanger Litres
Surface of charging heat exchanger m
Thermal output data
Hot water volume without reheating
at 8 l / min / 12 l / min draw-off rate
(TKW = 10 C / TWW = 40 C / TSP = 50 C)*
Litres 184 / 153 184 / 153 364 / 318
(328 / 276)**
364 / 318
(328 / 276)**
Hot water volume without reheating with
8l / min / 12 l / min draw-off rate
(TKW = 10 C / TWW = 40 C / TSP = 60 C)*
Litres 282 / 252 282 / 252 540 / 494 540 / 494
Hot water volume without reheating with
8l / min / 12 l / min draw-off rate
(TKW = 10 C / TWW = 40 C / TSP = 65 C)*
Litres 352 / 321 352 / 321 612 / 564 612 / 564
Reheating time draw-off volume
140 l -> 5820 Wh (bath draw off)
Min. 90 45 45 25
Reheating time draw-off volume
90 l -> 3660 Wh (shower draw off)
Min. 55 30 30 17
Pipe connections
Cold and hot water Inch 1" male thread 1" male thread 1" male thread 1" male thread
Heating inflow and return flow Inch 1" female thread 1" female thread 1" female thread 1" female thread
Technical data
Air-to-water heat pump, HPSU compact
Low Temperature
* with storage tank heat exchanger completely charged, ** Storage tank only charged with heat pump without immersion heater
Reheating time = The time needed to reheat the thermal store after a certain quantity of DHW has been discharged to a store temperature of 50 C
1) Only for devices heating and cooling
L
o
w

T
e
m
p
e
r
a
t
u
r
e
25
H
e
a
t

p
u
m
p
Heat pump
Technical data
Air-to-water heat pump, HPSU compact
Low Temperature
HPSU external unit for HPSU compact ~1 / 230 V ~1/230 V ~3 / 400 V
4kW 6kW 8kW 11kW 14kW 16kW 11kW 14kW 16kW
14 51 51 14 51 52 14 51 53 14 51 45 14 51 46 14 51 47 14 51 48 14 51 49 14 51 50
Basic data
Nominal heat output A-7 / W35 kW 4,37 5,29 5,53 6,0 8,3 8,0 6,0 8,3 8,0
Nominal heat output A2 / W35 kW 3,27 4,56 5,51 7,7 9,6 10,1 7,7 9,6 10,1
Nominal heat output A7 / W35 kW 4,4 6,22 7,78 11,8 14,8 15,3 11,8 14,8 15,3
Nominal heat output A10 / W35 kW 1) 1) 1) 11,5 14,5 16,1 11,5 14,5 16,1
Nominal COP A-7 / W35 2,81 2,85 2,78 2,45 2,58 2,44 2,45 2,58 2,44
Nominal COP A2 / W35 4,02 3,68 3,54 3,29 3,22 3,15 3,29 3,22 3,15
Nominal heat output A7 / W35 5,04 4,88 4,6 4,47 4,27 4,1 4,47 4,27 4,1
Nominal COP A10 / W35 5,12 5,18 4,9 4,6 4,41 4,31 4,6 4,41 4,31
Nominal EER A35 / W18 1) 3,99 3,64 3,32 2,96 2,72 3,32 2,96 2,72
Max. heat output A-7 / W35 kW 4,6 5,3 6,4 8,8 11,7 12,3 8,8 11,7 12,3
Max. heat output A2 / W35 kW 4,8 6,4 7,7 9,1 10,9 11,4 9,1 10,9 11,4
Max. heat output A7 / W35 kW 5,1 8,4 10,2 11,4 14,6 16,1 11,4 14,6 16,1
Max. heat output A10 / W35 kW 1) 1) 1) 11,9 15,0 16,5 11,9 15,0 16,5
Max. cooling output A35 / W18 kW 5,9 7,3 8,4 15,1 16,1 16,8 15,1 16,1 16,8
Max. cooling output A35 / W7 kW 4,5 5,5 6,4 11,7 12,6 13,1 11,7 12,6 13,1
Dimensions of unit (W x T x H) mm 832 x 307 x 735 900 x 320 x 1345 900 x 320 x 1345
Unit weight kg 54 / 56 114 114
Operating range, outside temperature (heating) C Min: -25 / Max: 25 Min: -25 / Max: 35 Min: -25 / Max: 35
Operating range, outside temperature (cooling) C Min: 10 / Max: 43 Min: 10 / Max: 46 Min: 10 / Max: 46
Operating range, outside temperature (DHW) C Min: -25 / Max: 35 Min: -20 / Max: 35 Min: -20 / Max: 35
Noise level Heating* dB (A) 48 48 49 51 51 52 51 51 52
Noise level Cooling* dB (A) 48 49 50 50 52 54 50 52 54
Noise level Heating dB (A) 61 61 62 64 64 66 64 64 66
Noise level Cooling dB (A) 63 63 63 64 66 69 64 66 69
Power supply, phase 1 ~ 1 ~ 3 ~
Power supply Frequency Hz 50 50 50
Power supply Voltage V 230 230 400
Inrush current A 18 22 13,5
Operating current (maximum) A 1) 34,2 16,3
Refrigerant R410A R410A R410A
Coolant volume (prefilled) kg 1,45 / 1,6 3,4 3,4
Connection refrigerant line
Gas lines

(mm) 5 / 8 (15,9) 5 / 8 (15,9) 5 / 8 (15,9)


Liquid line

(mm) 1 / 4 (6,4) 3 / 8 (9,5) 3 / 8 (9,5)


Refrigerant line length max. m 30 50 50
Refrigerant line length min. m 3 3 3
* at 1 m separation
1) Data not available when going to press
L
o
w

T
e
m
p
e
r
a
t
u
r
e
25
26
Heat pump
H
e
a
t

p
u
m
p
Technical data
Air-to-water heat pump, HPSU compact
Low Temperature
ROTEX G-plus gas auxiliary heating
14 07 00
Dimensions (W x D x H) mm 340 x 340 x 640
Weight kg 25
Voltage V 230
Frequency Hz 50
Min. output kW 3,5
Max. output kW 15
Max. effectiveness % 109
Water content l 2,5
Inflow temp. C 40 76
Suitable for gas types 2E, 2H, 2LL, 2L
Liquid gas 3P
Optional accessories: Supplementary heating (electric immersion
heater) backup heater
Output kW 9
Power supply, phase 3~*
Power supply Frequency Hz 50
Power supply Voltage V 400
Operating current A 3 x 13.1
* 1~ phase connection (3 x 230 V / 50 Hz) possible (except in Germany)
Technical data
Air-to-water heat pump, HPSU Bi-Bloc
Low Temperature
HPSU Internal unit
(LT Bi-Bloc)
HPSU LT Bi-Bloc
4 kW 6 8 kW 11 16 kW
14 41 70 / 14 41 72 14 41 71 / 14 41 73 14 41 76 / 14 41 75
Heating / Heating and cooling
Basic data
Colour white (RAL 9010)
Unit dimesnsions (W x D x H) mm 480 x 344 x 890
Unit weight kg 46 48
Operating range, flow temperature (heating) C Min: 15 / Max: 55 Min: 15 / Max: 55 Min: 15 / Max: 55 Min: 15 / Max: 55
Connection refrigerant line
Gas lines " (mm) 5/8 (15,9) 5/8 (15,9) 5/8 (15,9) 5/8 (15,9)
Liquid line " (mm) 1/4 (6,4) 3/8 (9,5) 1/4 (6,4) 3/8 (9,5)
Type Backup Heater 3V 9W
Heating output kW 3 9
Power supply, phase 1~ 3~
Power supply Frequency Hz 50 50
Power supply Voltage V 230 400
Operating current A 13 13
L
o
w

T
e
m
p
e
r
a
t
u
r
e
27
Heat pump
H
e
a
t

p
u
m
p
HPSU External unit Bi-Bloc Internal unit ~1 / 230 V ~1/230 V ~3 / 400 V
6kW 8kW 11kW 14kW 16kW 11kW 14kW 16kW
14 51 52 14 51 53 14 51 45 14 51 46 14 51 47 14 51 48 14 51 49 14 51 50
Basic data
Nominal heat output A-7 / W35 kW 5,31 5,46 8,6 10,0 11,1 8,6 10,0 11,1
Nominal heat output A2 / W35 kW 4,58 5,8 8,56 10,3 11,1 8,56 10,3 11,1
Nominal heat output A7 / W35 kW 6 7,4 11,2 14,5 16,0 11,2 14,5 16,0
Nominal heat output A10 / W35 kW 6,25 7,39 11,2 14,3 15,7 11,2 14,3 15,7
Nominal COP A-7 / W35 2,84 2,71 2,75 2,65 2,64 2,75 2,65 2,64
Nominal COP A2 / W35 3,68 3,53 3,6 3,41 3,35 3,6 3,41 3,35
Nominal heat output A7 / W35 4,74 4,45 4,6 4,3 4,25 4,6 4,3 4,25
Nominal COP A10 / W35 5,07 4,75 4,85 4,7 4,5 4,85 4,7 4,5
Nominal EER A35 / W18
2)
3,45 3,42 3,32 2,96 2,72 3,32 2,96 2,72
Max. heat output A-7 / W35 kW 5,3 6,4 8,8 11,7 12,3 8,8 11,7 12,3
Max. heat output A2 / W35 kW 6,4 7,7 9,1 10,9 11,4 9,1 10,9 11,4
Max. heat output A7 / W35 kW 8,4 10,2 11,4 14,6 16,1 11,4 14,6 16,1
Max. heat output A10 / W35 kW 1) 1) 1) 1) 1) 1) 1) 1)
Max. cooling output A35 / W18
2)
kW 7,3 8,4 15,1 16,1 16,8 15,1 16,1 16,8
Max. cooling output A35 / W7
2)
kW 5,5 6,4 11,7 12,6 13,1 11,7 12,6 13,1
Unit dimesnsions (W x D x H) mm 832 x 307 x 735 900 x 320 x 1345 900 x 320 x 1345
Unit weight kg 56 114 114
Operating range outdoor temperature
(Heating)
C Min: -25 / Max: 25 Min: -25 / Max: 35 Min: -25 / Max: 35
Operating range outdoor temperature
(Cooling)
2)
C Min: 10 / Max: 43 Min: 10 / Max: 46 Min: 10 / Max: 46
Operating range outdoor temperature
(tap water)
C Min: -25 / Max: 35 Min: -20 / Max: 35 Min: -20 / Max: 35
Noise level Heating* dB (A) 48 49 51 51 52 51 51 52
Noise level Cooling*
2)
dB (A) 49 50 50 52 54 50 52 54
Noise level Heating dB (A) 61 62 64 64 66 64 64 66
Noise level Cooling
2)
dB (A) 63 63 64 66 69 64 66 69
Power supply, phase 1 ~ 1 ~ 3 ~
Power supply Frequency Hz 50 50 50
Power supply Voltage V 230 230 400
Inrush current A 18 34,2 13,5
Operating current (maximum) A 1) 16,3 16,3
Refrigerant R410A R410A R410A
Coolant volume (prefilled) kg 1,6 3,4 3,4
Connection refrigerant line
Gas lines

(mm) 5 / 8 (15,9) 5 / 8 (15,9) 5 / 8 (15,9)


Liquid line

(mm) 1 / 4 (6,4) 3 / 8 (9,5) 3 / 8 (9,5)


Refrigerant line length max. m 30 50 50
Refrigerant line length min. m 3 3 3
Technical data
Air-to-water heat pump, HPSU Bi-Bloc
Low Temperature
* at 1 m separation
1) Data not available when going to press
2) Only for devices heating and cooling
L
o
w

T
e
m
p
e
r
a
t
u
r
e
27
28
Heat pump
H
e
a
t

p
u
m
p
Technical data
Air-to-water heat pump, HPSU monobloc
Low Temperature
HPSU monobloc ~1 /230 V ~3 / 400 V
11kW 16kW 11kW 16kW
14 31 73 14 31 75 14 31 76 14 31 78
Three phase with base plate heater
Nominal heat output A-7 / W35 * kW 6,5 9,2 6,5 9,2
Nominal heat output A2 / W35 * kW 8,1 10,7 8,1 10,7
Nominal heat output A10 / W35 * kW 11,8 16,4 11,8 16,4
Nominal COP A-7 / W35 * 2,5 2,4 2,5 2,4
Nominal COP A2 / W35 * 3,1 3,1 3,1 3,1
Nominal COP A10 / W35 * 4,6 4,3 4,6 4,3
Nominal cooling output A35 / W18 * kW 12,85 16,73 12,85 16,73
Nominal cooling output A35 / W7 * kW 10 13,1 10 13,1
Nominal EER A35 / W18 * 3,332 2,72 3,332 2,72
Nominal EER A35 / W7 * 2,71 2,28 2,71 2,28
Max. heat output A-7 / W35 ** kW 6,5 9,2 6,5 9,2
Max. heat output A2 / W35 ** kW 8,1 10,7 8,1 10,7
Max. heat output A10 / W35 ** kW 11,8 16,4 11,8 16,4
Max. cooling output A35 / W18 ** kW 12,85 16,73 12,85 16,73
Max. cooling output A35 / W7 ** kW 10 13,1 10 13,1
Operating range (outdoor temperature) **** HEATING C -20 ~ 35
(1)
Cooling C 10 ~ 46
Hot water C -20 ~ 35
(1) (2)
Noise level *** dB (A) 48 48 48 48
Noise level dB (A) 48 49 48 49
Weight kg 180
Refrigerant quantity R -410A kg 2,95
Power supply C 3N~ / 400 V / 50 Hz
Recommended fuses A 32 20
Measurement conditions: Heating Ta 7 C/ - TVL 35 C (dT = 5K) - Cooling Ta 35 C - TVL1 8 C (dT = 5 K)
(1)
Units can reach -25 C, but this performance cannot be guaranteed.
(2)
Operation of the auxiliary heater from 35 C upwards
* Measured in accordance with DIN EN 14511
** Measured at maximum speed
Compressor in accordance with Eurovent 6/C/003-2006
*** Measured at a distance of 1 m
**** It may be necessary for the installer to obtain and install a trace heater strip for the pipes installed
outside the unit. If a continuous power supply cannot be guaranteed, we recommend adding glycol
to the water circuit (see installation instructions).
L
o
w

T
e
m
p
e
r
a
t
u
r
e
29
Heat pump
H
e
a
t

p
u
m
p
Technical data
Air-to-water heat pump, HPSU
hitemp
High Temperature
HPSU
hitemp
(HT Bi-Bloc) External unit Internal unit
~3 / 400 V ~1 / 230 V ~3 / 400 V ~1 / 230 V
11 kW 14 kW 16 kW 11 kW 14 kW 16 kW 11 kW 14 kW 16 kW 11 kW 14 kW 16 kW
14 31 82 14 31 83 14 31 84 14 31 79 14 31 80 14 31 81 14 31 88 14 31 89 14 31 90 14 31 85 14 31 86 14 31 87
Performance data
Max. heat output A2 / W65 kW 9,6 11,9 13,5 9,6 11,9 13,5 9,6 11,9 13,5 9,6 11,9 13,5
Power consumption A2 / W65 kW 3,9 5 5,8 3,9 5 5,8
COP A2 / W65 2,48 2,38 2,33 2,48 2,38 2,33
Max. heat output A7 / W65 kW 11 14 16 11 14 16 11 14 16 11 14 16
Power consumption A7 / W65 kW 3,6 4,7 5,6 3,6 4,7 5,6
COP A7 / W65 3,08 3 2,88 3,08 3 2,88
Dimensions
Unit dimesnsions (W x D x H) 900 x 320 x 1345 600 x 695 x 705
Weight
Mass Net kg 120 147
Mass Gross kg 130 156
Compressor
Motor Type Fully hermetic scroll compressor Fully hermetic scroll compressor
Operating range
Heating applications C -25 to +20 -25 to +20
Domestic hot water generation C -25 to +35 -25 to +35
Flow max. C 80
Flow min. C 25
HW temperature min. C 25
HW temperature max. C 75
Noise level
Noise level* db (A) 52 53 55 52 53 55 43 45 46 43 45 46
Noise level* db (A) 68 69 71 68 69 71 59 60 60 59 60 60
Refrigerant
Type R410A R410A and R134a
Control Electronic expansion valve Electronic expansion valve
Max. line length m 50
Max. height difference m 30
Defrost method Process inversion
Output control Inverter controlled Inverter controlled
Power supply Y1 V1 Y1 V1
Phases 3~ 1~ 3~ 1~
Frequency Hz 50 50 50 50
Voltage V 380 415 220 240 380 415 220 240
Power consumption
Maximum operating current A 13,5 13,5 13,5 23,8 23,8 23,8 12,5 12,5 12,5 22,5 23,8 23,8
Recommended fuses A 16 16 16 25 25 25 16 16 16 25 25 25
Pump
Nominal ESP kPa 92 88 85 92 88 85
Power input w 87 95 101 87 95 101
Water side
Nominal flow rate l / min 15,8 20,1 22,9 15,8 20,1 22,9
* at 1m separation
H
i
g
h

T
e
m
p
e
r
a
t
u
r
e
29
30
Heat pump
H
e
a
t

p
u
m
p
HP convector
Article Type Order No. Price
HP convector
Blower convector for room heating and cooling with compact
dimensions and very quiet operation. The convector can be used both
for heating and cooling and is ideally suited for operation with a heat
pump. It can be used both in combination with underfloor heating
and a space-saving replacement for low-temperature radiators.
Theremote control with integrated temperature regulation facilitates
problem-free and rapid adaption to various different requirements.
The integrated air filter provides clean and pleasant room air.
HP convector 1.5 kW
HP convector 2.0 kW
RFWXV15AVEB
RFWXV20AVEB
14 20 10
14 20 11
680,00
830,00
HPc connection package
Thermally insulated flexible connecting line with fittings.
HPc-AP 14 20 12 83,00
HPc regulation package
This is required if the HPc is not connected via a heating circuit
distributor. Includes electrical 2-way valve, section regulation valve
and connecting fittings.
HPc-RP 14 20 13 159,00
HPc connecting cable
Cable for extension of the output signals of the HPSU compact for
connection of a HPc with cooling and heating function or actuation of
an external valve for bypassing the heating support exchanger.
HPc-VK-1 14 20 15 32,00
* at 1m separation
** In combination with underfloor heating (connected in the same circuit).
1) 2x (1 Kit per connection side HP convector / distributor)
Connection accessories on RMX heating circuit distributor
With VA pipe DN 16x2.2
- 2x adapter male thread l6- l/2" No. l9 50 4l
(See Installation system VA page 146)
- Clamplng rlng klt Mv l6 No. l7 03 l5
(See accessories heating circuit distributor RMX page 130)
Monopex pipe 14x2
- Connectlon nlpple "male thread X " No. l7 73 27
(See accessories heating circuit distributor RMX page 130)
- Clamplng rlng klt Mv l4 No. l7 03 l4
(See accessories heating circuit distributor RMX page 130)
1)
Connection accessories on HKV heating circuit distributor
With VA pipe DN 16x2.2
- 2x adapter male thread l6- l/2" No. l9 50 4l
(See Installation system VA page 146)
- Clamplng rlng klt L7 No. l7 70 l0
(See accessories heating circuit distributor HKV page 131)
Monopex pipe 14x2
- Connectlon nlpple "male thread X " No. l7 73 27
(See accessories heating circuit distributor RMX page 130)
- Clamplng rlng klt L2 No. l7 70 l2
(See accessories heating circuit distributor HKV page 131) 1)
Technical data
HP convector
HP convector RFWXV15A RFWXV20A
14 20 10 14 20 11
Performance data
Heating output kW 1,5 2
Cooling capacity kW 1,2 1,7
Application range
Water temperature min. C 6 / 18** 6 / 18**
Water temperature max. C 60 60
Dimensions
(W x D x H) mm 700 x 210 x 600 700 x 210 x 600
Weight kg 15 15
Noise level
Noise level (mid-range
ventilation)*
dB (A) 19 29
Power supply
Phases 1- 1-
Frequency Hz 50 / 60 50 / 60
Voltage V 220 240 220 240
31
Heat pump
H
e
a
t

p
u
m
p
Thermal store and solar storage tank,
ROTEX HybridCube
ROTEX Hygienic storage tank HYC
343 / 19 / 0-P
HYC
544 / 19 / 0-P
HYC
544 / 32 / 0-P
HYC
343 / 19 / 0-DB
HYC
544 / 19 / 0-DB
HYC
544 / 32 / 0-DB
Hygienic hot water generation in
instantaneous through-flow principle

Solar heating support

Electric immersion heater

Heat pump combinations
HPSU Low Temp to 8 kW

HPSU Low Temp to 16 kW

HPSU
hitemp

HPSU monobloc

Solar combination
Pressurised solar combination *
Drain-Back combination

* If a pressurised solar combination or a bivalency solaution is to be combined with a heat pump,
we can use the ROTEX compact heat pump HPSU compact Biv Variant. See pages 7, 8.
31
32
Heat pump
H
e
a
t

p
u
m
p
HPSU thermal store and solar storage tank,
ROTEX HybridCube
Article Type Order No. Price
HybridCube HYC 343 / 19 / 0-P
High-performance 300 litre energy store for
domestic hot water generation.
Dimensions (W x D x H) 595 x 615 x 1646 mm, weight 57 kg
HYC 343 / 19 / 0-P 14 05 54 1.649,00
HybridCube HYC 544 / 19 / 0-P
High-performance 500 litre stratified storage tank for
hot water generation and heating support.
Dimensions (W x D x H) 790 x 790 x 1,658 mm, weight 87 kg
HYC 544 / 19 / 0-P 14 05 61 1.879,00
HybridCube HYC 544 / 32 / 0-P
High-performance 500 litre stratified storage tank for
hot water generation and heating support.
Dimensions (W x D x H) 790 x 790 x 1,658 mm, weight 87 kg
HYC 544 / 32 / 0-P 14 05 63 2.039,00
HybridCube HYC 343 / 19 / 0-DB
High-performance 300 litre energy store for hot water generation.
Dimensions (W x D x H) 595 x 615 x 1,646 mm, weight 59 kg.
HYC 343 / 19 / 0-DB 14 05 53 1.469,00
HybridCube HYC 544 / 19 / 0-DB
High-performance 500 litre stratified storage tank for hot water
generation and heating support.
Dimensions (W x D x H) 790 x 790 x 1658 mm, weight 87 kg.
HYC 544 / 19 / 0-DB 14 05 60 1.679,00
HybridCube HYC 544 / 32 / 0-DB
High-performance 500 litre stratified storage tank for hot water
generation and heating support.
Dimensions (W x D x H) 790 x 790 x 1658 mm, weight 93 kg.
HYC 544 / 32 / 0-DB 14 05 62 1.819,00
33
HPSU thermal store and solar storage tank,
ROTEX HybridCube
Article Type Order No. Price
Stainless steel hot water storage tank
For combination with HPSU
hitemp
Internal unit or HPSU Bi-Bloc
(from Version BB of internal unit).
With HPSU
hitemp
Mounting on the internal unit is possible.
With individual installation next to the internal unit you will need the
mounting unit RKFMAHT for the HPSU
hitemp
.
For installation in combination with the HPSU Bi-Bloc you will need
the RKFMALTA kit.
With a capacity of 200 litres
Dimensions (W x D x H) 600 x 695 x 1,335 mm, weight 70 kg.
With a capacity of 260 litres
Dimensions (W x D x H) 600 x 695 x 1,610 mm, weight 78 kg.
RKHTS200AC
RKHTS260AC
14 05 10
14 05 11
1.755,00
1.999,00
Hot water storage tank installation kit
For individual installation of the stainless steel hot water storage tank
RKHTS200AC and RKHTS260AC next to the HPSU
hitemp
internal unit.
For installation of the stainless steel hot water storage tank
RKHTS200AC and RKHTS260AC in combination with the HPSU Bi-Bloc.
RKFMAHT
RKFMALTA
14 10 09
14 10 43
539,00
380,00
Enamel-coated stainless steel hot water storage tank
with a capacity of 300 litres.
Height: 1572 mm, diameter: 660 mm, weight: 140 kg
incl. integrated 3 kW electrical heating element. Please order hot
water storage tank sensors separately (order number 14 10 37).
RKHWE300A3V3 14 05 19 1480,00
Hot water storage tank sensors, LowTemp
To measure the water temperature in the storage tank.
Needed for storage tank RKHWE300A3V3 for the automatic
control at the heat pump device. Cable length: 12 metres.
SF LT 14 10 37 42,00
Heat pump
H
e
a
t

p
u
m
p
33
34
Heat pump
H
e
a
t

p
u
m
p
Technical data
Thermal store and solar storage tank,
ROTEX HybridCube
Technical data storage tank for heat pumps
for Bi-Bloc, monobloc, HPSU
hitemp
HYC 343 / 19 / 0-P HYC 544 / 19 / 0-P HYC 544 / 32 / 0-P
14 05 54 14 05 61 14 05 63
Basic data
Total storage capacity Litres 300 500 500
Empty weight kg 64 92 98
Total filled weight kg 364 592 598
Dimensions (W x D x H) mm 595 x 615 x 1646 790 x 790 x 1658 790 x 790 x 1658
Tilt dimension cm 170 167 167
Max. permissible storage water temperature C 85 85 85
Heat consumption at readiness and at 60 C
kWh /24h
1,3 1,4 1,4
Drinking water heating
Drinking water capacity Litres 27,9 29,0 29,0
Maximum operating pressure bar 6 6 6
Drinking water heat exchanger material stainless steel stainless steel stainless steel
Drinking water heat exchanger surface m 5,8 5,8 5,8
Storage tank charging heat exchanger (stainless steel)
Water capacity heat exchanger Litres 13,2 9,9 18,5
Surface of charging heat exchanger m 2,7 2,0 3,8
Solar heating support (stainless steel)
Water capacity heat exchanger Litres
Heat exchanger surface area m
Thermal output data
Hot water volume without re-heating
with 8 l / min / 12 l / min draw-off rate
(T
KW
= 10 C / T
WW
= 40 C / T
SP
= 50 C)
Litres 184 / 153 324 / 282
(288 / 240)*
324 / 282
(288 / 240)*
Hot water volume without re-heating
with 8 l / min / 12 l / min draw-off rate
(T
KW
= 10 C / T
WW
= 40 C / T
SP
= 60 C)
Litres 282 / 252 492 / 444 492 / 444
Hot water volume without re-heating
with 8 l / min / 12 l / min draw-off rate
(T
KW
= 10 C / T
WW
= 40 C / T
SP
= 65 C)
Litres 352 / 321 560 / 516 560 / 516
Re-heating time *
Draw off volume 140 l -> 5820 Wh
(bath draw off )
Min. 45
(HPSU 008)
45
(HPSU 008)
25
(HPSU 016)
Re-heating time *
Draw off volume 90 l -> 3660 Wh (shower draw
off )
Min. 30
(HPSU 008)
30
(HPSU 008)
17
(HPSU 016)
Pipe connections
Cold and hot water Inch 1" male thread 1" male thread 1" male thread
Heating inflow and return flow Inch 1" female thread / 1" male
thread
1" female thread / 1" male
thread
1" female thread / 1" male
thread
Drain-back connection Inch
Pressure solar connection Inch 3/4 female thread 3/4 female thread 3/4 female thread
35
Heat pump
Technical data
Thermal store and solar storage tank,
ROTEX HybridCube
* Storage tank only charged with heat pump without immersion heater
Reheating time = The time needed to reheat the thermal store to a temperature of 50 C after a certain quantity of DHW has been discharged.
Suitable solar system ROTEX Solaris from page 110. Storage tank accessories see page 102.
HYC 343 / 19 / 0-DB HYC 544 / 19 / 0-DB HYC 544 / 32 / 0-DB RKHTS 200 RKHTS 260
14 05 53 14 05 60 14 05 62 14 05 10 14 05 11
300 500 500 201 258
59 87 93 70 78
359 587 593 271 336
595 x 615 x 1646 790 x 790 x 1658 790 x 790 x 1658 695 x 600 x 1335 695 x 60 x 1610
163 167 167 - -
85 85 85 75 75
1,3 1,4 1,4 1,2 1,5
27,9 29,0 29,0 193,5 250,5
6 6 6 10 10
stainless steel stainless steel stainless steel
5,8 6,0 6,0
13,2 9,9 18,5 7,5 7,5
2,7 2,0 3,8 1,56 1,56
2,3 2,3
0,5 0,5
184 / 153 364 / 318
(328 / 276)*
364 / 318
(328 / 276)*
255 / 251 330 / 326
282 / 252 540 / 494 540 / 494 320 / 316 415 / 411
352 / 321 612 / 564 612 / 564 352 / 348 457 / 453
45
(HPSU 008)
45
(HPSU 008)
25
(HPSU 016)
30
(HPSU
hitemp
016)
40
(HPSU
hitemp
016)
30
(HPSU 008)
30
(HPSU 008)
17
(HPSU 016)
1" male thread 1" male thread 1" male thread 3 / 4" female thread 3 / 4" female thread
1" female thread / 1" male
thread
1" female thread / 1" male
thread
1" female thread / 1" male
thread
3 / 4" female thread 3 / 4" female thread
1" female thread 1" female thread 1" female thread

H
e
a
t

p
u
m
p
35
36
Boiler
B
o
i
l
e
r
ROTEX A1 oil condensing boiler
ROTEX A1 oil condensing
- Floor-standing oil condensing boiler
- Power spectrum 12 to 34 kW
- Oil blue burner, integrated regulated high-efficiency pump, LAS connection and condensate treatment
- Integrated electronic convenience regulation ROTEX RoCon B1
- Simple and consistent handling for ROTEX A1, GCU compact and HPSU compact
- Clear text display with multi-coloured background lighting for visualisation of status and error messages
- Intuitive menu guiding
- Peady for blo-oll (820)
- Patented and multl-award wlnnlng Tw|NTLC technology
- l5 year guarantee on the boller body
Our confidence in guaranteeing optimum functionality, particularly in terms of noise emissions from our heat generators,
is based on the use of genuine ROTEX flue gas systems. This optimised and adapted to all ROTEX oil condensing boiler and
gas condensing boilers.
37
B
o
i
l
e
r
Boiler
37
38
Article Type Order No. Price
A1 BO 15-e 12 to 15 kW A1 BO 15-e 15 49 60 4.199,00
A1 BO 20-e 12 to 20 kW A1 BO 20-e 15 49 61 4.249,00
A1 BO 27-e 20 to 27 kW A1 BO 27-e 15 49 62 4.699,00
A1 BO 34-e 27 to 34 kW A1 BO 34-e 15 49 63 5.349,00
Attention: Please order the connecting kit A1 (storage tank temperature sensor, connecting fittings, 3-way switch valve),
safety group and outdoor sensor separately.
Additional regulation accessories Type Order No. Price
Room controller
Convenience regulation with wall housing
For use as
a) A remote control (external equipment controller)
b) Mixer unit (additional or standalone)
c) Room thermostat for heat exchanger.
RoCon U1 15 70 34 159,00
Mixer module
Controller for mixer valve with speed-controlled high-efficiency pump
including mixer circuit flow temperature sensor
a) in combination with an equipment controller (RoCon B1).
Mixer parameters adjustable via the heat generator
(up to 16 mixer modules).
b) in combination with room controller (RoCon U1)
1. can be used as a standalone solution
2. can be integrated in the system via BUS.
RoCon M1 15 70 68 169,00
Outdoor sensor for RoCon convenience regulation RoCon OT1 15 60 70 29,00
Storage tank sensor for RoCon DT1 convenience regulation
Suitable for all A1 oil condensing boilers. Is only required,
if no A1 connection-set is ordered.
RoCon DT1 15 60 68 29,00
Accessories for all ROTEX A1 Type Order No. Price
Boiler support frame 400 mm,
With removable casing made of plastic
KU 15 30 21 289,00
Safety group for the A1 product range
With pressure gauge, 3 bar over-pressure valve, automatic bleeding,
MAG connections, filling cock and connector.
SBG A1 15 60 18 89,00
Mixer group for all ROTEX heat generators
For a mixed heating circuit.
Ready to plug in, in the thermal insulation case, with high-efficiency
circulation pump, motor mixer, stops valves and temperature
displays.
MK1 15 60 67 799,00
Mixer group for all ROTEX heat generators
For a mixed heating circuit.
Ready to plug in, in the thermal insulation case, with PWM-
controlled high-efficiency circulation pump, motor mixer, stops
valves and temperature displays. (Available from June 2013)
MK2 15 60 72 799,00
Fittings kit for mixer group MK
1 female thread x 1 1 / 2 flat-sealing.
VMK1 15 60 53 21,00
Additive against limescale and corrosion
"FERNOX" concentrate cartridge with connecting adapter
and hose, pack size 290 ml.
Enough for 100 150 l heating water.
KSK 15 60 50 127,00
ROTEX A1 oil condensing boiler
Boiler
B
o
i
l
e
r
39
Boiler
Accessories for all ROTEX A1 Type Order No. Price
Connection Set A1
Consisting of storage tank temperature sensor, connection fittings
and 3-way switching valve 1" with 230 V motor drive
(switching time 6 secs.) for hydraulic connection of a thermal
store to the A1 condensing boiler. For installation of the VSA1 it is
neccesary to mount the security group SBG A1.
VSA1 15 48 22 169,00
Dirt filter
For intercepting dirt in the heater return flow.
Input 3/4" female thread, Output 1" female thread
up to 28 kW
up to 50 kW
SFR 28
SFR 50
15 60 11
15 60 12
148,35
169,95
Sludge and magnetic separator
Compact sludge separator with drain cock and
thermal insulation.
Input G1-IG (union nut), outlet G1-lG.
SAS 1 15 60 21 199,00
ROTEX A1 oil condensing boiler accessories Type Order No. Price
Burner-conversion kit for BL15 / BLB20
- Nominal output 12 14 kW (oil nozzle 0.30 / 80H)
URS12 15 46 15 23,00
Burner conversion kit for BL27
- Nominal output 20 24 kW (oil nozzle 0.50 / 80H, air nozzle 22)
URS20 15 46 24 77,50
Burner conversion kit for BLB34
- Nominal output 25 27 kW (oil nozzle 0.55 / 80H)
- Nominal output 33 34 kW (oil nozzle 0.65 / 80H, air nozzle 27)
URS25
URS34
15 46 28
15 46 35
26,90
79,00
Additional oil connection adaptor
Plug in adaptor for connecting up additional plant components,
e.g. solenoid valves, temperature monitors, oil feed pump
ZS 15 40 71 149,00
Microtec oil filter cartridge, short
Microtec oil filter cartridge, long
MC7
MC18
15 60 13
15 60 14
16,00
17,00
Neutralising agent
For topping up the NBO condensate treatment
NKN 15 45 75 35,60
Service case SKA1 2013 for A1 oil
For all A1 oil condensing boilers from 3/2013
SKA1 2013 15 41 70 1.279,00
ROTEX A1 oil condensing boiler
Type Pack size Order No. Price, each Price / Pack
VA-Oil feeding line
PEX-AL compound pipe as oil supply line approved by the building supervision authorities in the DIBT test.
Test mark of the building supervision authority: Z-40.23-331
Thick-walled PEX inner pipe with butt-welded aluminium covering and silver-grey PE external layer.
Due to the aluminium covering 100 % diffusion tightness. Neutral to heating oil, prevents degradation in the heating oil.
Type of delivery: Ring coil packaged in box.
VA oil pipe, 12 x 3 60 m 17 06 31 2,35 / m 141,25
Connection screwed fitting VA-Oil
For connection the oil feed pipe VA-oil to the extraction armature and to the oil filter.
Clamping ring screwed fitting made of brass or parts in contact with oil made of stainless steel.
Suitable for VA-Oil pipe 12 x 3, connecting thread 3 / 8 male thread
Test mark of the building supervision authority: Z-40.23-331
Connection screwed fitting VA-Oil VAR1 10 pieces. 17 80 13 10,15 / piece 101,45
Connect VA-Oil
10 m PEX-AL compound pipe as
an oil-conveying line with two
screwed connection fittings
12 x 3 - 3 / 8 male thread
10 m 17 06 32 55,00
B
o
i
l
e
r
39
40
Boiler
Article Type Order No. Price
A1 BG 25-e 5 to 25 kW A1 BG 25-e 15 59 35 3.999,00
A1 BG 25F-e 5 to 25 kW for liquid gas A1 BG 25-e 15 59 36 4.099,00
A1 BG 40-e 8 to 40 kW A1 BG 40-e 15 59 42 4.999,00
A1 BG 40F-e 8 to 40 kW for liquid gas A1 BG 40-e 15 59 43 5.099,00
Attention: Please order the connecting kit A1 (storage tank temperature sensor, connecting fittings, 3-way switch valve)
separately. See page 38. Accessories page 38, 39.
ROTEX A1 gas condensing boiler
ROTEX A1 gas condensing boiler
- Floor-standing gas condensing boiler
- Power spectrum 5 to 40 kW
- Modulating burner operation
- Gas surface burner, integrated regulated high-efficiency pump, LAS connection
- Integrated electronic convenience regulation ROTEX RoCon B1
- Simple and consistent handling for ROTEX A1, GCU compact and HPSU compact
- Clear text display with multi-coloured background lighting for visualisation
of status and error messages
- Intuitive menu guiding
- Patented and multi-award winning TWINTEC technology
- 15 year guarantee on the boiler body
Our confidence in guaranteeing optimum functionality, particularly in terms of noise emissions from our heat generators,
is based on the use of genuine ROTEX flue gas systems. This is optimised and adapted to all ROTEX oil condensing and
gas condensing boilers.
B
o
i
l
e
r
41
Boiler
Condensing boiler with low-toxin oil blue burner or
modulating gas surface burner, regulation RoCon B1,
high-efficiency pump and LAS connection for room-air
independent operation.
Oil condensing boiler Gas condensing boilers
A1 BO 15-e A1 BO 20-e A1 BO 27-e A1 BO 34-e A1 BG 25-e A1 BG 40-e
modulating
Nominal output according to DIN-EN 303 kW 15 20 24 34 5 25 8 40
Ready for bio-oil
Fully
equipped
Fully
equipped
Fully
equipped
Fully
equipped

Factory setting kW / %* 15 18 25 30 30 80 * 30 80 *
Setting range in standard equipment
1)
kW / %* 15 15 20 24 27 27 32 20 100 * 20 100 *
Permissible operating excess pressure bar 4 4 4 4 4 4
Max. permissible feed temperature C 80 80 80 80 80 80
Max. boiler efficiency % 105 105 105 105 109 109
Circulation pump high-efficiency, regulated - ErP-ready (EEI < 0.23)
3)

Flue gas temperature C 35 75 35 85 38 89 40 98 32 60 34 82
Weight of the boiler body kg 49 49 58 67 49 67
Total weight Unit
2)
kg 81 81 96 113 77 107
Length cm 72 72 72 72 72 72
Width cm 62,5 62,5 62,5 62,5 62,5 62,5
Height cm 110 110 122 134 110 134
Minimum height of the installation room cm 134 134 147 159 134 159
Water content Litres 3 3 4,5 5 3 5
Flue gas / supply air connection diameter mm 80 / 125 80/125 80 / 125 80 / 125 80 / 125 80 / 125
Order No. 15 49 60 15 49 61 15 49 62 15 49 63 15 59 35 15 59 42
Control RoCon B1 RoCon B1 RoCon B1 RoCon B1 RoCon B1 RoCon B1
*Can be parametrised via RoCon controller
1) For smaller or greater outputs of the A1 condensing boiler you will need conversion kits - see accessories.
2) Transport weight with the lining and condensate treatment unit removed.
3) From 2015, the European ErP Guidelines will only permit the use of pumps with an energy efficiency index < 0.23 in boilers.
From 2020, these requirements will also apply to spare parts. All the ROTEX condensing boilers A1 and GCU are already fitted with pumps
that will be permitted up to and beyond 2020.
Flue gas systems from page 52
Technical data
ROTEX A1 oil/gas condensing boilers
B
o
i
l
e
r
41
42
B
o
i
l
e
r
Boiler
Gas condensing/solar combination, ROTEX GCU compact
ROTEX GCU compact
- Floor-standing gas condensing boiler with integrated hot water or solar storage tank
- Power spectrum 5 to 33 kW
- Storage tank volume 300 or 500 litres
- Solar option (Drain-Back)
- Gas-adaptive combustion system SCOT with fully-electronic gas-air compound
- Unit ready to plug in with regulated high-efficiency pump, 3-way switch valve and LAS connection
- Integrated electronic convenience regulation ROTEX RoCon B1
- Simple and consistent handling for ROTEX A1, GCU compact and HPSU compact
- Clear text display with multi-coloured background lighting for visualisation of status and error messages
- Intuitive menu guiding
Additional features for Version Biv:
- 8lvalency optlon for lntegratlon of an addltlonal heat source or a pressurlsed solar system (8lv)
Our confidence in guaranteeing optimum functionality, particularly in terms of noise emissions from our heat generators,
is based on the use of genuine ROTEX flue gas systems. This optimised and adapted to all ROTEX oil condensing boiler and
gas condensing boilers.
43
B
o
i
l
e
r
Boiler
Article Type Order No. Price
GCU compact Biv
Output-modulating from 5 15 kW for natural and liquid
gas, storage tank volume 300 litres, additional pressurised
heat exchanger for solar applications or external heat
generator.
GCU compact 315 Biv 15 74 02 3.709,00
GCU compact Biv
Output-modulating from 5 24 kW for natural and liquid
gas, storage tank volume 300 litres, additional pressurised
heat exchanger for solar applications or external heat
generator.
GCU compact 324 Biv 15 74 08 3.869,00
GCU compact Biv
Output-modulating from 5 15 kW for natural and liquid
gas, storage tank volume 500 litres, additional pressurised
heat exchanger for solar applications or external heat
generator.
GCU compact 515 Biv 15 74 04 4.339,00
GCU compact Biv
Output-modulating from 5 24 kW for natural and liquid
gas, storage tank volume 500 litres, additional pressurised
heat exchanger for solar applications or external heat
generator.
GCU compact 524 Biv 15 74 06 4.499,00
GCU compact Biv
Output-modulating from 5 33 kW for natural and liquid
gas, storage tank volume 500 litres, additional pressurised
heat exchanger for solar applications or external heat
generator.
GCU compact 533 Biv 15 74 07 4.659,00
GCU compact
Output-modulating from 5 15 kW,
storage tank volume 300 litres for natural and liquid gas
GCU compact 315 15 74 01 3.299,00
GCU compact
Output-modulating from 5 24 kW,
storage tank volume 300 litres for natural and liquid gas
GCU compact 324 15 74 09 3.459,00
GCU compact
Output-modulating from 5 15 kW,
storage tank volume 500 litres for natural and liquid gas
GCU compact 515 15 74 03 3.929,00
GCU compact
Output-modulating from 5 24 kW,
storage tank volume 500 litres for natural and liquid gas
GCU compact 524 15 74 10 4.089,00
GCU compact
Output-modulating from 5 33 kW,
storage tank volume 500 litres for natural and liquid gas
GCU compact 533 15 74 05 4.249,00
Regulation accessories Type Order No. Price
Room controller
Convenience regulation with wall housing
For use as
a) A remote control (external equipment controller)
b) Mixer operating unit (additional or standalone)
c) Room thermostat for heat exchanger.
RoCon U1 15 70 34 159,00
Mixer module
Controller for mixer valve with speed-controlled high-
efficiency pump including mixer circuit sensor
a) in combination with an equipment controller (RoCon B1).
Mixer parameters adjustable via the heat generator.
b) in combination with room controller (RoCon U1)
1. can be used as a standalone solution
2. can be integrated in the system via BUS.
RoCon M1 15 70 68 169,00
Outdoor sensor for RoCon convenience regulation RoCon OT1 15 60 70 29,00
Tip:
GCU compact
available from
June 2013.
Gas condensing/solar combination, ROTEX GCU compact
43
44
Boiler
B
o
i
l
e
r
Accessories Type Order No. Price
Flue-gas kit GCU compact
Double-walled connection set of 2x45 elbows with
connection extender
from DN60 / 100 to DN80 / 125.
AAS1 GCU c 15 50 79.17 169,00
Mixer group for all ROTEX heat generators
For a mixed heating circuit.
Ready to plug in, in the thermal insulation case, with
high-efficiency circulation pump, motor mixer, stops
valves and temperature displays.
MK1 15 60 67 799,00
Mixer group for all ROTEX heat generators
For a mixed heating circuit.
Ready to plug in, in the thermal insulation case, with
PWM-controlled high-efficiency circulation pump, motor
mixer, stops valves and temperature displays. (Available
from June 2013)
MK2 15 60 72 799,00
Fittings kit for mixer group MK
1 female thread x 1 1 / 2 flat-sealing.
VMK1 15 60 53 21,00
Safety module for the GCU compact
Product range
With pressure gauge, 3 bar over-pressure valve,
automatic bleeder, MAG connection and filling cock.
SBG GCU compact 15 70 46 89,00
Sludge and magnetic separator
Compact sludge separator with drain cock and thermal
insulation. Input G1-IG (union nut), outlet G1-lG.
SAS1 15 60 21 199,00
Service case for GCU compact
(from year of manufacture 06 / 2013)
SKGCUc1 15 41 72 929,00
Gas condensing/solar combination, ROTEX GCU compact
45
Boiler
B
o
i
l
e
r
45
46
Boiler
B
o
i
l
e
r
Technical data GCU compact GCU compact
315 Biv
GCU compact
324 Biv
GCU compact
515 Biv
GCU compact
524 Biv
GCU compact
533 Biv
Basic data 15 74 02 15 74 08 15 74 04 15 74 06 15 74 07
Total storage capacity Litres 300 300 500 500 500
Empty weight kg 86 86 124 124 124
Total filled weight kg 386 386 624 624 624
Dimensions (W x D x H) mm 595 x 615 x 1945 595 x 615 x 1945 790 x 790 x 1951 790 x 790 x 1951 790 x 790 x 1951
Max. permissible storage water temperature C 85 85 85 85 85
Stand-by heating power kWh / 24h 1,7 1,7 1,8 1,8 1,8
Control RoCon RoCon RoCon RoCon RoCon
Circulation pump high-efficiency, regulated - ErP ready (EEI < 0.23)
3)
Drinking water heating
Drinking water capacity Litres 19 19 24,5 24,5 24,5
Maximum operating pressure bar 6 6 6 6 6
Material domestic water heat exchanger stainless steel stainless steel stainless steel stainless steel stainless steel
Drinking water heat exchanger surface m 4 4 5 5 5
Storage tank charging / discharging heat exchanger (stainless steel)
Water capacity heat exchanger Litres 9,4 9,4 10,5 10,5 19,3
Surface of charging heat exchanger m 1,9 1,9 2,1 2,1 4
Pressurised solar heat exchanger (stainless steel)
Water capacity heat exchanger Litres 4,2 4,2 12,5 12,5 12,5
Surface of charging heat exchanger m 0,8 0,8 1,7 1,7 1,7
Thermal output data
NL efficiency characteristic acc. to DIN 4708
1)
2 2,1 2,1 2,1 2,2
D value (specific water flow) acc. to EN625
2)
l / min 22 24 23 25 27
Continuous output in accordance with
DIN4708 Qn
kW 15 24 15 24 33
Max. draw-off rate for a period of 10 min at
(TKW = 10 C / TWW = 40 C / TSP = 60 C)
l / min 19 21 20 23 24
Hot water volume without reheating at
15 l / min draw-off rate
(TKW = 10 C / TWW = 40 C / TSP = 60 C)
Litres 200 200 230 230 230
Hot water volume with reheating at
15 l / min with draw-off rate
(TKW = 10 C / TWW = 40 C / TSP = 60 C)
Litres 300 400 370 600 1300
Short-term water quantity in 10min Litres 190 210 200 230 240
Heat generator characteristic data
Nominal output kW 5 15 5 24 5 15 5 24 5 33
Rated thermal load kW 5,5 16 5,5 25 5,5 16 5,5 25 5,5 34
Device type B
23
/ B
23P
/ B
33
/ B
53
/ B
53P
/ C
13x
/ C
33x
/ C
43x
/ C
53x
/ C
63x
/ C
83x
Electrical data V / Hz 230 / 50 230 / 50 230 / 50 230 / 50 230 / 50
Protection type IP 20 20 20 20 20
Maximum permissible operating pressure bar 3 3 3 3 3
Maximum permitted operating temperature C 85 85 85 85 85
Maximum boiler efficiency % 110 110 110 110 110
Flue gas / air infeed connection diameter mm DN 60 / 100 (with connection kit No. 155079.17 DN 80 / 125)
Pipe connections
Cold and hot water Inch 1" male thread 1" male thread 1" male thread 1" male thread 1" male thread
Heating inflow and return flow Inch 1" female thread 1" female thread 1" female thread 1" female thread 1" female thread
Technical data GCU compact
47
1)
At nominal output, 80 C feed temperature,
65 C storage tank temperature, 45 C hot water
temperature and 10 C cold water temperature
2)
Explanation: The specific water flow to EN 625 is the
flow of drinking water at an average temperature
increase of 30 K that the GCU compact can supply
during two consecutive draw-offs of 10 minutes
each, starting from a charging temperature of 65 C.
The standard calls for a delay between the draw-
offs of 20 minutes. The GCU compact achieves this
value even at shorter delay periods.
3)
From 2015, the European ErP Guidelines will
only permit the use of pumps with an energy
efficiency index < 0.23 in boilers. From 2020,
these requirements will also apply to spare parts.
AllROTEX condensing boilers A1 and GCU compact
are already equipped with pumps that will be
permitted up to and beyond 2020.
GCU compact
315
GCU compact
324
GCU compact
515
GCU compact
524
GCU compact
533
15 74 01 15 74 09 15 74 03 15 74 10 15 74 05
300 300 500 500 500
86 86 124 124 124
386 386 624 624 624
595 x 615 x 1945 595 x 615 x 1945 790 x 790 x 1951 790 x 790 x 1951 790 x 790 x 1951
85 85 85 85 85
1,7 1,7 1,8 1,8 1,8
RoCon RoCon RoCon RoCon RoCon
high-efficiency, regulated - ErP ready (EEI < 0.23)
3)
19 19 24,5 24,5 24,5
6 6 6 6 6
stainless steel stainless steel stainless steel stainless steel stainless steel
4 4 5 5 5
9,4 9,4 10,5 10,5 19,3
1,9 1,9 2,1 2,1 4
- - - - -
- - - - -
2 2,1 2,1 2,1 2,2
22 24 23 25 27
15 24 15 24 33
19 21 20 23 24
200 200 230 230 230
300 400 370 600 1300
190 210 200 230 240
5 15 5 24 5 15 5 24 5 33
5,5 16 5,5 25 5,5 16 5,5 25 5,5 34
B
23
/ B
23P
/ B
33
/ B
53
/ B
53P
/ C
13x
/ C
33x
/ C
43x
/ C
53x
/ C
63x
/ C
83x
230 / 50 230 / 50 230 / 50 230 / 50 230 / 50
20 20 20 20 20
3 3 3 3 3
85 85 85 85 85
110 110 110 110 110
DN 60 / 100 (with connection kit No. 155079.17 DN 80 / 125)
1" male thread 1" male thread 1" male thread 1" male thread 1" male thread
1" female thread 1" female thread 1" female thread 1" female thread 1" female thread
Boiler
B
o
i
l
e
r
Technical data GCU compact
47
48
Gas condensing wall-mounted boiler ROTEX GW
Boiler
Article Type Order No. Price
ROTEX GW
Version C
Wall-mounted gas condensing unit compact unit with integrated
hygienic hot water generation in the instantaneous through-flow
principle
4,5 21.6 kW (80 / 60 C), 3-step pump
5,2 24.2 kW (50 / 30 C), 3-step pump
5,8 26.2 kW (80 / 60 C), 3-step pump
6.6 29.1 kW (50 / 30 C), 3-step pump
8,5 36.5 kW (80 / 60 C), high efficiency pump
9,6 40.0 kW (50 / 30 C), high efficiency pump
GW 22C
GW 26C
GW 37C
15 00 28
15 00 29
15 00 30
2.359,00
2.449,00
2.569,00
Article Type Order No. Price
ROTEX GW
Version T
Wall-mounted gas condesning compact unit with integrated
3-way valve for storage tank charging
4,5 21.6 kW (80 / 60 C), 3-step pump
5,2 24.2 kW (50 / 30 C), 3-step pump
5,8 26.2 kW (80 / 60 C), 3-step pump
6,6 29.1 kW (50 / 30 C), 3-step pump
8,5 36.5 kW (80 / 60 C), high efficiency pump
9,6 40.0 kW (50 / 30 C), high efficiency pump
GW 22T
GW 26T
GW 37T
15 00 31
15 00 32
15 00 33
2.099,00
2.189,00
2.279,00
* Accessories external temperature sensor TA GW 150042 is required
- Wall-mounted gas condensing boiler
- Power spectrum 4.5 to 40 kW
- Version C - with integrated hygienic hot water generation in instantaneous through-flow principle
- Version T - with integrated 3-way valve for storage tank charging
- Modulation ration of 1:5 (100 % 20 %) for optimum adaption to the output demand
- Integrated safety group, diaphragm expansion vessel, flue gas test adapter DN 60 /100 and weather-controlled Regulation*
- NO
X
class 5
Our confidence in guaranteeing optimum functionality, particularly in terms of noise emissions from our heat generators,
is based on the use of genuine ROTEX flue gas systems. This is optimised and adapted to all ROTEX oil condensing and
gas condensing boilers.
B
o
i
l
e
r
49
Gas condensing wall-mounted boiler ROTEX GW
Boiler
Article Type Order No. Price
Hydraulic connection kit GW
Connection kit for simple connection of the ROTEX GW
with existing standard piping (65-58-58-65). Consisting of
connecting lines and isolation valves.
GWHYA1 15 00 40 99,00
External temperature sensor GW
The external temperature sensor provides weather-
controlled regulation of the ROTEX GW.
TA-GW 15 00 42 29,00
Room station for remote control of the ROTEX GW
Clear text display and pre-configured operating buttons
The functions in overview:
- Remote control for the ROTEX GW
- Remote query of operating conditions and temperatures
- Weekly timer programme (up to 4 heating phases per
day can be selected individually)
- Presence and holday function
- Eco functions
- Room influence switching with weather-controlled feed
flow temperature is possible
- Just room temperature regulation is possible
- Automatic summer / winter switching
GW-QAA73 15 00 41 169,00
Double wall reducer test adapter
DN 60 / 100 to DN 80 / 125
When using a DN 80 / 125 flue gas system
D8 PA-GW 15 50 79.01 43 149,00
Flue gas line component kit GW1
Double-wall connection line DN 80 / 125 between GW and
duct
1)
/ wall
2)
for flue gas connection to the rear or to the
side, for room-air independent operation, complete with
seals and inspection elbows.
(see flue gas system GW)
SET GW1 15 50 79.15 289,00
Flue gas line component set GW2
LAS central heating plant in roof, double-walled flue
gas / supply air pipe DN 80 / 125 for GW installation in roof
space for room-air independent operation, complete with
seals, inspection pipe and roof penetration box (black) up
to height of 1.80 m.
Attention: Roof covers to be ordered separately
(see flue gas system GW).
SET GW2 15 50 79.16 319,00
B
o
i
l
e
r
49
50
Boiler
Gas condensing combi boiler Unit GW22C GW26C GW 37C
Nominal heat output P
n
(80 / 60 C) kW 4,5 21,6 5,8 26,2 8,5 36,5
Nominal heat output with condensation P
no
(50 / 30 C) kW 5,2 24,2 6,6 29,1 9,6 40,0
Nominal heat load Q
n
kW 4,8 22,4 6,1 27,1 8,9 37,7
Efficiency % up to 109 %
NO
x
class 5 (< 60 mg / kWh)
Maximum flue gas temperature C 74 81
Maximum permissible operational overpressure (heating) PMS bar 3
Maximum permissible inflow temperature C 85
Empty weight kg 36 38 44
Water content L 1,8 2,7 3,5
Size (W x D x H) mm 405 x 345 x 733 405 x 410 x 733 405 x 440 x 733
Heating connections Inch " male thread
Cold and hot water connection Inch " male thread
Gas connection Inch " male thread
Flue gas / supply air diameter DN 60 / 100
Maximum length of flue gas system DN 60 / 100 m 6
Maximum length of flue gas system DN 80 / 125 m 12 7
Gas types Natural gas and liquid gas*)
*) After unit changeover
Device type B
23
B
23P
B
33
B
33P
C
13
C
33
C
43
C
53
C
63
C
83
Product identification number CE-0051CL4018
Automatic firing + regulation Siemens LMU84
Gas valve Siemens VGU86S.A
Burner fan Ebm-Papst NRG 118 / LN2 NG40
Heating circulation pump Grundfos UPSO 15-60 CES GF UPM 15-70
Operating voltage V / Hz -220 / 50
Maximum electrical power consumption
(including heating circulation pump)
w 110 70
Protection type IPX4D
Domestic water temperature C 40 65
Specific water flow 0 (EN 13203) (40 / 10 C) l / min 12 14 17
Minimum water flow D
m
l / min 2,1 2,3
Domestic water convenience (EN 13203) 66/
Minimum / maximum permissible operating pressure drinking
water PMW
bar 0,5 / 10
Integrated diaphragm expansion vessel: Index l 7 10 10
Electrical connection for room station GW-OAA73 OpenTherm-twin wire BUS supply via BUS line,
max. 50 m, d 2x5 :, connections interchangeable
Technical data
Gas condensing wall-mounted boiler ROTEX GW
C-Version
B
o
i
l
e
r
51
Boiler
Gas condensing combi boiler Unit GW22T GW26T GW 37T
Nominal heat output P
n
(80 / 60 C) kW 4,5 21,6 5,8 26,2 8,5 36,5
Nominal heat output with condensation P
no
(50 / 30 C) kW 5,2 24,2 6,6 29,1 9,6 40,0
Nominal heat load Q
n
kW 4,8 22.4 6,1 27,1 8,9 37,7
Efficiency % up to 109%
NO
x
class 5 (< 60 mg / kWh)
Maximum flue gas temperature C 74 81
Maximum permissible operational overpressure (heating) PMS bar 3
Maximum permissible inflow temperature C 85
Empty weight kg 36 38 44
Water content L 1,8 2,7 3,5
Size (W x D x H) mm 405 x 345 x 733 405 x 410 x 733 405 x 440 x 733
Heating connections Inch " male thread
Gas connection Inch " male thread
Flue gas / supply air diameter DN 60 / 100
Maximum length of flue gas system DN 60 / 100 m 6
Maximum length of flue gas system DN 80 / 125 m 12 7
Gas types Natural gas and liquid gas*)
*) After unit changeover
Device type - B
23
B
23P
B
33
B
33P
C
13
C
33
C
43
C
53
C
63
C
83
Product identification number - CE-0051CL4018
Automatic firing + regulation - Siemens LMU84
Gas valve - Siemens VGU86S.A
Burner fan - Ebm-Papst NRG 118 / LN2 NG40
Heating circulation pump - Grundfos UPSO 15-60 CES GF UPM 15-70
Operating voltage V / Hz -220 / 50
Maximum electrical power consumption
(including heating circulation pump)
w 110 70
Protection type IPX4D
Domestic water convenience (EN 13203) 66/
Integrated diaphragm expansion vessel: Index l 7 10 10
Electrical connection for room station GW-OAA73 OpenTherm-twin wire BUS supply via BUS line,
max. 50 m, d 2x5 :, connections interchangeable
Technical data
Gas condensing wall-mounted boiler ROTEX GW
T-Version
B
o
i
l
e
r
51
52
Installation kits and essential accessories
System No. page
1 A1 room-air independent - flue gas pipe DN 80 in shaft 54
2 A1 room-air independent - flue gas pipe DN 110 in shaft 56
3 A1 room-air dependent - flue gas pipe DN 80 in shaft 58
4 A1 room-air dependent - flue gas pipe DN 110 in shaft 60
5 GCU compact room-air independent - flue gas pipe DN 80 in shaft 62
6 GCU compact room-air independent - flue gas pipe DN 110 in shaft 64
7 A1 room-air independent - flexible flue gas pipe DN 80 and DN 110 in shaft 66
8 GCU compact room-air independent - flexible flue gas pipe DN 80 and DN 110 in shaft 68
9 A1, GSU compact room-air independent - as central heating plant in roof DN 80 / 125 70
10 A1 room-air independent - external wall flue gas pipe DN 80 / 125 72
11 A1 room-air independent - external wall flue gas pipe DN 110 / 160 74
12 GCU compact room-air independent - external wall flue gas pipe DN 80 / 125 76
13 GCU compact room-air independent - external wall flue gas pipe DN 110 / 160 78
14 GW room-air independent - rigid and flexible flue gas line DN 80 in shaft 80
15 GW room-air independent - external wall flue gas pipe / roof heating centre DN 80 / 125 82
Flue gas system accessories: Individual components
E1 Single-walled components DN 80 84
E2 Single-walled components DN 110 85
E3 Double-walled components DN 80 / 125 86
E4 Double-walled components DN 110 / 160 88
E5 Components for use outdoors (stainless steel) DN 80 / 125 89
E6 Components for use outdoors (stainless steel) DN 110 / 160 91
E7 Components for flexible flue gas pipe in shaft DN 80 92
E8 Components for flexible flue gas pipe in shaft DN 110 93
Table with overview of various applications
System No. Heat
generator
Operating
mode
Rigid flue gas line
in shaft
Flexible flue gas line
in shaft
Roof heating
centre
DN 80 / 125
External wall
flue gas pipe
RLUA RLA DN 80 DN 110 DN 80 DN 110 DN 80 / 125 DN 110 / 160
1 A1 X X 54
2 A1 X X 56
3 A1 X X 58
4 A1 X X 60
7 A1 - . X X 66
9 A1 X X 70
10 A1 X . X 72
11 A1 X . X 74
5 GCU
compact
X X 62
6 GCU
compact
X X 64
8 GCU
compact
- . X X 68
9 GCU
compact
X X 70
12 GCU
compact
X . X 76
13 GCU
compact
X . X 78
14 GW X . X X 80
15 GW X X X 82
RLUA Ambient-air-independent
RLA Ambient air-dependent
X Described application
- Application recommended - not described differentiated
. Application possible - recommended less
Dimensional data
Maximum permissible height, flue gas mass rate
94
F
l
u
e

g
a
s

s
y
s
t
e
m
Overview
Flue gas system
53
Overview
Flue gas system
F
l
u
e

g
a
s

s
y
s
t
e
m
Our confidence in guaranteeing optimum functionality, particularly in terms of noise emissions from
our heat generators, is based on the use of genuine ROTEX flue gas systems.
All ROTEX oil and gas-condensing boilers have been optimised and adapted accordingly.
Installation versions for ROTEX oil and gas heat generators
Air 1) Ambient air-independent mode
2) Partial ambient air-independent mode
3) Ambient air-independent mode Flue gas
a) Longitudinally ventilated shaft with a fire-resistance period of 90 minutes 30 minutes in low height residential buildings.
b) Moisture-insensitive flue gas pipe as defined by DIN 14471
(temperature class T 120 or higher, condensation resistance class W, corrosion resistance class 2)
c) Ventilation opening 1 x 150 cm
2
oder 2 x 75 cm
2
d) Rear ventilation
t All flue gas pipes*) approved for use in condensing technology can be used - a connection adapter may be required!
t Condensate draw-off: Neutralisation is always necessary with oil condensing boilers and standard heating oil EL!
If low-sulphur heating oil is used, neutralisation of the condensate may not be necessary,
depending on the local regulations governing waste water emissions. Observe the local regulations concerning waste water!
*) Minimum requirements in accordance with EN 14471: Temperature class T 120, pressure class P1, condensation resistance class W,
corrosion resistance class 2
53
54
Basic sets Type Order No. Price
Set C
Straight double-walled connection pipe DN 80 / 125 between boiler and
shaft
1)
/ wall
2)
, complete with seals, test adapter and inspection pipe.
(installation version 1 and 4)
SET-C 15 50 79.03 285,75
Set D
Double-walled connecting pipe DN 80 / 125 for height-offset connection
between boiler and shaft
1)
/wall
2)
, complete with seals, test adapter and
inspection elbows. (installation version 1 and 4)
SET-D 15 50 79.04 387,70
Kit E
Single wall flue gas pipe DN 80 for installation in fire resistant shaft complete with
seals, chimney support, chimney head cover, length 10 m including spacers.
(installation version 1, 2 and 3)
SET-E 15 50 79.05 279,00
Kit E / ES
Single wall flue gas pipe DN 80 for installation in fire resistant shaft complete with
seals, chimney support, chimney head cover in stainless steel, length 10 m
including spacers (installation version 1, 2 and 3)
SET-E / ES 15 50 79.14 450,65
Double-walled - white Type Order No. Price
Double-walled flue gas pipe DN 80 / 125
Powder-coated white RAL 9016
Length 250 mm D8 L25 15 50 79.01 02 39,80
Length 500 mm D8 L50 15 50 79.01 03 40,70
Length 1,000 mm D8 L100 15 50 79.01 04 59,55
Length 2,000 mm D8 L200 15 50 79.01 05 120,85
Double-walled flue gas elbow DN 80 / 125
Powder-coated white RAL 9016
15 D8 B15 15 50 79.00 19 56,80
30 D8 B30 15 50 79.00 20 56,80
45 D8 B45 15 50 79.01 01 56,80
87 D8 B87 15 50 79.01 00 57,60
Double-walled inspection pipe DN 80 / 125
Powder-coated white RAL 9016
D8 RR 15 50 79.00 99 103,00
Double-walled inspection elbow DN 80 / 125
Powder-coated white RAL 9016
D8 RB 15 50 79.00 98 103,55
Double-walled test adapter DN 80 / 125
Powder-coated white RAL 9016
D8 PA 15 50 79.00 93 74,60
Double-walled wall lead-through DN 80 / 125
With wall sleeve
D8 MD 15 50 79.01 13 40,80
Wall bracket for double-walled flue pipe DN 80 / 125
For indoors
D8 WH 15 50 79.00 62 17,85
A1 room-air independent - flue gas pipe DN 80 in shaft
System No. 1
A1 flue gas system
1)
with installation variant 1
2)
with installation variant 4
F
l
u
e

g
a
s

s
y
s
t
e
m
55
A1 flue gas system
For additional accessory parts, see pages 84 93
Single-wall - white Type Order No. Price
Single-walled flue gas pipe DN 80
Length 250 mm E8 L25 15 50 79.00 73 16,70
Length 500 mm E8 L50 15 50 79.00 72 19,90
Length 1,000 mm E8 L100 15 50 79.00 71 24,55
Length 2,000 mm E8 L200 15 50 79.00 70 35,45
Single-walled flue gas elbow DN 80
15 E8 B15 15 50 79.00 11 15,05
30 E8 B30 15 50 79.00 13 15,05
45 E8 B45 15 50 79.01 09 11,55
87 E8 B87 15 50 79.01 08 11,55
Single-walled inspection pipe DN 80 E8 RR 15 50 79.01 07 46,15
Spacer kit DN 80
6 pieces.
E8 AH 15 50 79.00 30 42,45
Flue gas opening noise damper DN 80
Suitable for all mouth moulds apart from flexible shaft pipes
E8 MSD 15 45 78 89,00
*accessories if required
F
l
u
e

g
a
s

s
y
s
t
e
m
55
56
Basic sets Type Order No. Price
Set C
Straight double-walled connection pipe DN 80 / 125 between boiler and shaft
1)
/ Wall
2)
,
complete with seals, test adapter and inspection pipe.
(installation version 1 and 4)
SET-C 15 50 79.03 285,75
Set D
Double-walled connecting pipe DN 80 / 125 for height-offset connection
between boiler and shaft
1)
/ wall
2)
, complete with seals, test adapter and inspection elbows. (instal-
lation version 1 and 4)
SET-D 15 50 79.04 387,70
Set M
Single-wall flue gas pipe DN 110 for installation in fire-resistant shaft,
complete with seals, chimney support and chimney head cover.
For boiler-side connection to connection pipe DN 80 ( / 125) with eccentric wall outlet.
Length 10 m including spacers (installation version 1, 2 and 3)
SET-M 15 50 77.01 619,90
Double-walled - white Type Order No. Price
Double-walled flue gas pipe DN 80 / 125
Powder-coated white RAL 9016
Length 250 mm D8 L25 15 50 79.01 02 39,80
Length 500 mm D8 L50 15 50 79.01 03 40,70
Length 1,000 mm D8 L100 15 50 79.01 04 59,55
Length 2,000 mm D8 L200 15 50 79.01 05 120,85
Double-walled flue gas elbow DN 0 / 125
Powder-coated white RAL 9016
15 D8 B15 15 50 79.00 19 56,80
30 D8 B30 15 50 79.00 20 56,80
45 D8 B45 15 50 79.01 01 56,80
87 D8 B87 15 50 79.01 00 57,60
Double-walled inspection pipe DN 80 / 125
Powder-coated white RAL 9016
D8 RR 15 50 79.00 99 103,00
Double-walled inspection elbow DN 80 / 125
Powder-coated white RAL 9016
D8 RB 15 50 79.00 98 103,55
Double-walled test adapter DN 80 / 125
Powder-coated white RAL 9016
D8 PA 15 50 79.00 93 74,60
Double-walled wall lead-through DN 80 / 125
With wall sleeve
D8 MD 15 50 79.01 13 40,80
Wall bracket for double-walled flue pipe DN 80 / 125
For indoors
D8 WH 15 50 79.00 62 17,85
A1 room-air independent - flue gas pipe DN 110 in shaft
System No. 2
A1 flue gas system
1)
with installation variant 1
2)
with installation variant 4
F
l
u
e

g
a
s

s
y
s
t
e
m
57
A1 flue gas system
For additional accessory parts, see pages 84 93 ** Delivery period available on request.
Single-walled Type Order No. Price
Single-walled flue gas pipe DN 110 Length 250 mm E11 L25 15 50 77.00 04 30,50
Length 500 mm E11 L50 15 50 77.00 03 39,30
Length 1,000 mm E11 L100 15 50 77.00 02 43,20
Length 2,000 mm E11 L200 15 50 77.00 01 50,30
Single-walled inspection pipe DN 110 E11 RR 15 50 77.00 09 67,10
Spacer kit DN 110
6 pieces.
F11 AH 15 50 77.00 13 59,75
Flue gas opening noise damper DN 110
Suitable for all mouth moulds apart from flexible shaft pipes
E11 MSD 15 45 79 176,00
Chimney head covering with junction pipe DN 110
Stainless steel, incl. fixings
E11 KAES 15 50 77.00 14 204,90
Double-walled wall lead-through
Eccentric extension DN 80 / 125 to DN 110 / 160
D8 / 11 MD 15 50 77.00 39 ** 146,70
*accessories if required
F
l
u
e

g
a
s

s
y
s
t
e
m
57
58 58
Basic sets Type Order No. Price
Kit A
Straight single-walled connection pipe DN 80 between boiler and shaft, complete with
seals, test adapter and inspection pipe. (installation version 2, 3, 7 and 8)
SET-A 15 50 79.01 103,00
Kit B
Single-walled connecting pipe DN 80 for height-offset connection between boiler and shaft,
complete with seals, test adapter and inspection pipe (installation version 2, 3, 7 and 8).
SET-B 15 50 79.02 133,40
Kit E
Single wall flue gas pipe DN 80 for installation in fire resistant shaft complete with seals,
chimney supports, chimney head cover, length 10 m including spacers.
(installation version 1, 2 and 3)
SET-E 15 50 79.05 279,00
Kit E / ES
Single-walled flue gas pipe DN 80 for installation in fire-resistant shaft, complete with seals,
chimney support, stainless steel chimney head covering, length 10 m including spacer.
(installation version 1, 2 and 3)
SET-E / ES 15 50 79.14 450,65
Single-walled Type Order No. Price
Single-walled flue gas pipe DN 80 Length 250 mm E8 L25 15 50 79.00 73 16,70
Length 500 mm E8 L50 15 50 79.00 72 19,90
Length 1,000 mm E8 L100 15 50 79.00 71 24,55
Length 2,000 mm E8 L200 15 50 79.00 70 35,45
Single-walled flue gas elbow DN 80 15 E8 B15 15 50 79.00 11 15,05
30 E8 B30 15 50 79.00 13 15,05
45 E8 B45 15 50 79.01 09 11,55
87 E8 B87 15 50 79.01 08 11,55
Single-walled inspection pipe DN 80 E8 RR 15 50 79.01 07 46,15
Single-walled inspection elbow DN 80 E8 RB 15 50 79.01 06 46,15
Single-walled test adapter DN 80 E8 PA 15 50 70.00 52 35,65
Spacer kit DN 80
6 pieces.
E8 AH 15 50 79.00 30 42,45
Flue gas opening noise damper DN 80
Suitable for all mouth moulds apart from flexible shaft pipes
E8 MSD 15 45 78 89,00
Air supply silencer
For A1 boiler with operation dependent on ambient air
G ZLSD 15 45 77 49,00
A1 room-air dependent - flue gas pipe DN 80 in shaft
System No. 3
A1 flue gas system
F
l
u
e

g
a
s

s
y
s
t
e
m
59 59
A1 flue gas system
For additional accessory parts, see pages 84 93
*accessories if required
F
l
u
e

g
a
s

s
y
s
t
e
m
59 59
60
Basic sets Type Order No. Price
Kit A
Straight single-walled connection pipe DN 80 between boiler and shaft, complete with seals,
test adapter and inspection pipe. (installation version 2, 3, 7 and 8)
SET-A 15 50 79.01 103,00
Set B
Single wall connection pipe DN 80 for the height offset connection between
boiler and shaft, complete with seals, test adapter and inspection pipe.
(installation version 2, 3, 7 and 8)
SET-B 15 50 79.02 133,40
Set M
Single wall flue gas pipe DN 110 for installation in fire resistant shaft complete with seals,
chimney support and chimney head cover.
For boiler-side connection to connection pipe DN 80 ( / 125) with eccentric wall outlet.
Length 10 m including spacers (installation version 1, 2 and 3)
SET-M 15 50 77.01 619,90
Single-walled - DN 80 Type Order No. Price
Single-walled flue gas pipe DN 80 Length 250 mm E8 L25 15 50 79.00 73 16,70
Length 500 mm E8 L50 15 50 79.00 72 19,90
Length 1,000 mm E8 L100 15 50 79.00 71 24,55
Length 2,000 mm E8 L200 15 50 79.00 70 35,45
Single-walled flue gas elbow DN 80 15 E8 B15 15 50 79.00 11 15,05
30 E8 B30 15 50 79.00 13 15,05
45 E8 B45 15 50 79.01 09 11,55
87 E8 B87 15 50 79.01 08 11,55
Single-walled inspection pipe DN 80 E8 RR 15 50 79.01 07 46,15
Single-walled inspection elbow DN 80 E8 RB 15 50 79.01 06 46,15
Single-walled test adapter DN 80 E8 PA 15 50 70.00 52 35,65
A1 room-air dependent - flue gas pipe DN 110 in shaft
System No. 4
A1 flue gas system
1)
with installation variant 1
2)
with installation variant 4
F
l
u
e

g
a
s

s
y
s
t
e
m
61
A1 flue gas system
For additional accessory parts, see pages 84 93 ** Delivery period available on request.
Single-walled - DN 110 Type Order No. Price
Single-walled flue gas pipe DN 110 Length 250 mm E11 L25 15 50 77.00 04 30,50
Length 500 mm E11 L50 15 50 77.00 03 39,30
Length 1,000 mm E11 L100 15 50 77.00 02 43,20
Length 2,000 mm E11 L200 15 50 77.00 01 50,30
Single-walled inspection pipe DN 110 E11 RR 15 50 77.00 09 67,10
Spacer kit DN 110
6 pieces.
F11 AH 15 50 77.00 13 59,75
Flue gas opening noise damper DN 110
Suitable for all mouth moulds apart from flexible shaft pipes
E11 MSD 15 45 79 176,00
Chimney head covering with junction pipe DN 110
Stainless steel, incl. fixings
E11 KAES 15 50 77.00 14 204,90
Double-walled wall lead-through
Eccentric extension DN 80 / 125 to DN 110 / 160
D8 / 11 MD 15 50 77.00 39 ** 146,70
*accessories if required
F
l
u
e

g
a
s

s
y
s
t
e
m
61
62
Basic sets Type Order No. Price
Set GCU1
Double-walled flue gas connection kit for all GCU compact for connection
to flue gas system components DN 80/125
SET-GCU1 15 50 79.17 169,00
Kit H
Double-walled connecting pipe DN 80 / 125 between GSU compact and shaft
1)
/ wall
2)

for flue gas connection to the rear, for room-air independent operation, complete with seals,
test adapter and inspection pipe. (installation version 1 and 4)
SET-H 15 50 79.08 294,20
Set K
Double-walled connecting pipe DN 80 / 125 between GSU compact and shaft
1)
/ wall
2)

for side flue gas connection, for operation independent of ambient air, complete with seals,
test adapter and inspection elbow. (installation version 1 and 4)
SET-K 15 50 79.09 347,00
Kit E
Single wall flue gas pipe DN 80 for installation in fire resistant shaft complete with seals,
chimney supports, chimney head cover, length 10 m including spacers.
(installation version 1, 2 and 3)
SET-E 15 50 79.05 279,00
Kit E/ES
Single-wall flue gas pipe DN 80 for installation in fire-resistant shaft, complete with seals,
chimney support and chimney head cover in stainless steel,
Length 10 m including spacers (installation version 1, 2 and 3)
SET-E / ES 15 50 79.14 450,65
Single-walled - DN 80 Type Order No. Price
Double-walled flue gas pipe DN 80 / 125
Powder-coated white RAL 9016
Length 250 mm D8 L25 15 50 79.01 02 39,80
Length 500 mm D8 L50 15 50 79.01 03 40,70
Length 1,000 mm D8 L100 15 50 79.01 04 59,55
Length 2,000 mm D8 L200 15 50 79.01 05 120,85
Double-walled flue gas elbow DN 0 / 125
Powder-coated white RAL 9016
15 D8 B15 15 50 79.00 19 56,80
30 D8 B30 15 50 79.00 20 56,80
45 D8 B45 15 50 79.01 01 56,80
87 D8 B87 15 50 79.01 00 57,60
Double-walled inspection pipe DN 80 / 125
Powder-coated white RAL 9016
D8 RR 15 50 79.00 99 103,00
Double-walled inspection elbow DN 80 / 125
Powder-coated white RAL 9016
D8 RB 15 50 79.00 98 103,55
Double-walled test adapter DN 80 / 125
Powder-coated white RAL 9016
D8 PA 15 50 79.00 93 74,60
Double-walled wall lead-through DN 80 / 125
With wall sleeve
D8 MD 15 50 79.01 13 40,80
Wall bracket for double-walled flue pipe DN 80 / 125
For indoors
D8 WH 15 50 79.00 62 17,85
GCU compact room-air independent - flue gas pipe DN 80 in shaft
System No. 5
1)
with installation variant 1
2)
with installation variant 4
F
l
u
e

g
a
s

s
y
s
t
e
m
Flue gas system GCU compact
63
** Delivery period available on request.
Single-walled - DN 110 Type Order No. Price
Single-walled flue gas pipe DN 80 Length 250 mm E8 L25 15 50 79.00 73 16,70
Length 500 mm E8 L50 15 50 79.00 72 19,90
Length 1,000 mm E8 L100 15 50 79.00 71 24,55
Length 2,000 mm E8 L200 15 50 79.00 70 35,45
Single-walled flue gas elbow DN 80 15 E8 B15 15 50 79.00 11 15,05
30 E8 B30 15 50 79.00 13 15,05
45 E8 B45 15 50 79.01 09 11,55
87 E8 B87 15 50 79.01 08 11,55
Single-walled inspection pipe DN 80 E8 RR 15 50 79.01 07 46,15
Spacer set DN 80
6 in number
E8 AH 15 50 79.00 30 42,45
Flue gas opening noise damper DN 80
Suitable for all junction shapes apart from flexible shaft lines
E8 MSD 15 45 78 89,00
F
l
u
e

g
a
s

s
y
s
t
e
m
Flue gas system GCU compact
For additional accessory parts, see pages 84 93
*accessories if required
63
64
GCU compact room-air independent - flue gas pipe DN 110 in shaft
System No. 6
Flue gas system GCU compact
1)
with installation variant 1
2)
with installation variant 4
Basic sets Type Order No. Price
Set GCU1
Double-walled flue gas connection kit for all GCU compact for connection
to flue gas system components DN 80/125
SET-GCU1 15 50 79.17 169,00
Set H
Double-walled connecting pipe DN 80 / 125 between GSU compact and shaft
1)
/ wall
2)

for flue gas connection to the rear, for room-air independent operation, complete with seals,
test adapter and inspection pipe. (installation version 1 and 4)
SET-H 15 50 79.08 294,20
Set K
Double-walled connecting pipe DN 80 / 125 between GSU compact and shaft
1)
/ wall
2)

for flue gas connection at side, for room-air independent operation, complete with seals,
test adapter and inspection bend. (installation version 1 and 4)
SET-K 15 50 79.09 347,00
Set M
Single-wall flue gas pipe DN 110 for installation in fire-resistant shaft, complete
with seals, chimney support and chimney head cover.
For boiler-side connection to connection pipe DN 80 ( / 125) with eccentric
wall outlet. Length 10 m including spacers (installation version 1, 2 and 3)
SET-M 15 50 77.01 619,90
Double-walled - white Type Order No. Price
Double-walled flue gas pipe DN 80 / 125
Powder coated white RAL 9016
Length 250 mm D8 L25 15 50 79.01 02 39,80
Length 500 mm D8 L50 15 50 79.01 03 40,70
Length 1,000 mm D8 L100 15 50 79.01 04 59,55
Length 2,000 mm D8 L200 15 50 79.01 05 120,85
Double-walled flue gas elbow
DN 80 / 125
Powder-coated white RAL 9016
15 D8 B15 15 50 79.00 19 56,80
30 D8 B30 15 50 79.00 20 56,80
45 D8 B45 15 50 79.01 01 56,80
87 D8 B87 15 50 79.01 00 57,60
Double-walled inspection pipe DN 80 / 125
Powder-coated white RAL 9016
D8 RR 15 50 79.00 99 103,00
Double-walled inspection elbow DN 80 / 125
Powder-coated white RAL 9016
D8 RB 15 50 79.00 98 103,55
Double-walled test adapter DN 80 / 125
Powder-coated white RAL 9016
D8 PA 15 50 79.00 93 74,60
Double-walled wall lead-through DN 80 / 125
With wall sleeve
D8 MD 15 50 79.01 13 40,80
Wall bracket for double-walled flue pipe DN 80 / 125
For indoors
D8 WH 15 50 79.00 62 17,85
F
l
u
e

g
a
s

s
y
s
t
e
m
65
Flue gas system GCU compact
For additional accessory parts, see pages 84 93 ** Delivery period available on request.
Double-walled - white Type Order No. Price
Single-walled flue gas pipe DN 110 Length 250 mm E11 L25 15 50 77.00 04 30,50
Length 500 mm E11 L50 15 50 77.00 03 39,30
Length 1,000 mm E11 L100 15 50 77.00 02 43,20
Length 2,000 mm E11 L200 15 50 77.00 01 50,30
Single-walled inspection pipe DN 110 E11 RR 15 50 77.00 09 67,10
Spacer kit DN 110
6 pieces.
F11 AH 15 50 77.00 13 59,75
Flue gas opening noise damper DN 110
Suitable for all mouth moulds apart from flexible shaft pipes
E11 MSD 15 45 79 176,00
Chimney head covering with junction pipe DN 110
Stainless steel, incl. fixings
E11 KAES 15 50 77.00 14 204,90
Double-walled wall lead-through
Eccentric extension DN 80 / 125 to DN 110 / 160
D8 / 11 MD 15 50 77.00 39 ** 146,70
F
l
u
e

g
a
s

s
y
s
t
e
m
*accessories if required
65
66
Basic sets Type Order No. Price
Set C
Straight double-walled connection line DN 80 / 125 between boiler and shaft
1)
/ wall
2)
,
complete with seals, test adapter and inspection pipe.
(installation version 1 and 4)
SET-C 15 50 79.03 285,75
Set D
Straight double-walled connection line DN 80 / 125 for height offset connection between boiler
and shaft
1)
/ wall
2)
, complete with seals, test adapter and inspection elbow.
(installation version 1 and 4)
SET-D 15 50 79.04 387,70
Kit O
Single-walled flue gas pipe DN 80 for installation in fire-resistant shaft, complete with seals,
chimney support, chimney head covering and connector, length 12.7 m including spacer.
(installation variant 1, 2 and 3)
SET-O 15 50 79.13 695,50
Kit P
Single-walled flue gas pipe DN 110 for installation in fire-resistant shaft, complete with seals,
chimney support, chimney head covering and connector, length 15.5 m including spacer.
(installation variant 1, 2 and 3)
SET-P 15 50 77.03 1.300,70
Double-walled - white Type Order No. Price
Double-walled flue gas pipe DN 80 / 125
Powder-coated white RAL 9016
Length 250 mm D8 L25 15 50 79.01 02 39,80
Length 500 mm D8 L50 15 50 79.01 03 40,70
Length 1,000 mm D8 L100 15 50 79.01 04 59,55
Length 2,000 mm D8 L200 15 50 79.01 05 120,85
Double-walled flue gas elbow DN 80 / 125
Powder-coated white RAL 9016
15 D8 B15 15 50 79.00 19 56,80
30 D8 B30 15 50 79.00 20 56,80
45 D8 B45 15 50 79.01 01 56,80
87 D8 B87 15 50 79.01 00 57,60
Double-walled inspection pipe DN 80 / 125
Powder-coated white RAL 9016
D8 RR 15 50 79.00 99 103,00
Double-walled inspection elbow DN 80 / 125
Powder-coated white RAL 9016
D8 RB 15 50 79.00 98 103,55
Flexible DN 80 Type Order No. Price
Flexible flue gas pipe DN 80
Powder-coated white RAL 9016
Length 12.5 m F8 L1250 15 50 79.00 31 394,70
Length 25 m F8 L2500 15 50 79.00 32 787,95
Length 50 m F8 L5000 15 50 79.00 33 ** 1.575,90
Spacer kit DN 80
6 pieces.
E8 AH 15 50 79.00 30 42,45
Inspection pipe DN 80
For flexible flue gas pipe
F8 RR 15 50 79.00 63 155,55
Installation aid for flexible flue gas pipe DN 110
With 20 m rope
F8 MH 15 50 79.00 44 128,15
A1 room-air independent - flexible flue gas pipe DN 80 and DN 110
in shaft, System No. 7
1)
with installation variant 1
2)
with installation variant 4 **

Delivery period available on request.
A1 flue gas system
F
l
u
e

g
a
s

s
y
s
t
e
m
67
A1 flue gas system
For additional accessory parts, see pages 84 93 ** Delivery period available on request.
Type Order No. Price
Coupling for flexible flue pipe DN 80 F8 K 15 50 79.00 61 128,75
Connection sleeve DN 80
For transition from flexible to rigid flue pipe
F8 VM 15 50 79.00 34 61,50
Chimney head cover for flex pipe with junction pipe DN 80,
Stainless steel, incl. fixings
F8 KAES 15 50 79.01 32 ** 232,25
Flexible DN 110 Type Order No. Price
Flexible flue gas pipe DN 110
Length 15 m
F11 L1500 15 50 77.00 54 879,35
Spacer set DN 110
6 in number
F11 AH 15 50 77.00 13 59,75
Inspection pipe DN 110
For flexible flue gas pipe
F11 RR 15 50 77.00 48 262,15
Installation aid DN 110
For flexible flue gas pipe with 20 m rope
F11 MH 15 50 77.00 49 194,40
Coupling
For flexible flue gas pipe DN 110
F11 K 15 50 77.00 46 228,60
Connection sleeve DN 110
For transition from flexible to rigid flue gas pipe
F11 VM 15 50 77.00 47 191,40
Chimney head cover for flex pipe with junction pipe DN 110,
Stainless steel, incl. fixings
F11 KAES 15 50 77.00 50 ** 329,40
*accessories if required
F
l
u
e

g
a
s

s
y
s
t
e
m
67
68
Basic sets Type Order No. Price
Set GCU1
Double-walled flue gas connection kit for all GCU compact for connection
to flue gas system components DN 80/125
SET-GCU1 15 50 79.17 169,00
Set H
Double-walled connecting pipe DN 80 / 125 between GSU compact and shaft
1)
/wall
2)

for flue gas connection to the rear, for room-air independent operation, complete with seals,
test adapter and inspection pipe. (installation version 1 and 4)
SET-H 15 50 79.08 294,20
Set K
Double-walled connecting pipe DN 80 / 125 between GSU compact and shaft
1)
/ wall
2)

for flue gas connection at side, for room-air independent operation, complete with seals,
test adapter and inspection bend. (installation version 1 and 4)
SET-K 15 50 79.09 347,00
Kit O
Single-walled flexible flue gas pipe DN 80 for installation in fire-resistant shaft,
complete with seals, chimney support, chimney head cover and connection piece,
Length up to 12.7 m including spacers (installation version 1, 2 and 3)
SET-O 15 50 79.13 695,50
Kit P
Single-walled flexible flue gas pipe DN 110 for installation in fire-resistant shaft,
complete with seals, chimney support, chimney head cover and connection piece,
Length up to 15.5 m including spacers (installation version 1, 2 and 3)
SET-P 15 50 77.03 1.300,70
Double-walled - white Type Order No. Price
Double-walled flue gas pipe DN 80 / 125
Powder-coated white RAL 9016
Length 250 mm D8 L25 15 50 79.01 02 39,80
Length 500 mm D8 L50 15 50 79.01 03 40,70
Length 1,000 mm D8 L100 15 50 79.01 04 59,55
Length 2,000 mm D8 L200 15 50 79.01 05 120,85
Double-walled flue gas elbow DN 80 / 125
Powder-coated white RAL 9016
15 D8 B15 15 50 79.00 19 56,80
30 D8 B30 15 50 79.00 20 56,80
45 D8 B45 15 50 79.01 01 56,80
87 D8 B87 15 50 79.01 00 57,60
Double-walled inspection pipe DN 80 / 125
Powder-coated white RAL 9016
D8 RR 15 50 79.00 99 103,00
Double-walled inspection elbow DN 80 / 125
Powder-coated white RAL 9016
D8 RB 15 50 79.00 98 103,55
Flexible DN 80 Type Order No. Price
Flexible flue gas pipe DN 80
Powder-coated white RAL 9016
Length 12.5 m F8 L1250 15 50 79.00 31 394,70
Length 25 m F8 L2500 15 50 79.00 32 787,95
Length 50 m F8 L5000 15 50 79.00 33 ** 1.575,90
Spacer kit DN 80
6 pieces.
E8 AH 15 50 79.00 30 42,45
Inspection pipe DN 80
For flexible flue gas pipe
F8 RR 15 50 79.00 63 155,55
Installation aid DN 80
For flexible flue gas pipe with 20 m rope
F8 MH 15 50 79.00 44 128,15
GCU compact room-air independent - flexible flue gas pipe DN 80 and DN 110
in shaft, System No. 8
Flue gas system GCU compact
1)
with installation variant 1
2)
with installation variant 4 **

Delivery period available on request.
F
l
u
e

g
a
s

s
y
s
t
e
m
69
Flue gas system GCU compact
For additional accessory parts, see pages 84 93 ** Delivery period available on request.
Type Order No. Price
Coupling
For flexible flue pipe DN 80
F8 K 15 50 79.00 61 128,75
Connection sleeve DN 80
For transition from flexible to rigid flue pipe
F8 VM 15 50 79.00 34 61,50
Chimney head cover
For flexpipe with junction pipe DN 80, stainless steel,
including fixings
F8 KAES 15 50 79.01 32 ** 232,25
Flexible DN 110 Type Order No. Price
Flexible flue gas pipe DN 110
Length 15 m
F11 L1500 15 50 77.00 54 879,35
Spacer kit DN 110
6 pieces.
F11 AH 15 50 77.00 13 59,75
Inspection pipe DN 110
For flexible flue gas pipe
F11 RR 15 50 77.00 48 262,15
Installation aid DN 110
For flexible flue gas pipe with 20 m rope
F11 MH 15 50 77.00 49 194,40
Coupling
For flexible flue gas pipe DN 110
F11 K 15 50 77.00 46 228,60
Connection sleeve DN 110
For transition from flexible to rigid flue pipe
F11 VM 15 50 77.00 47 191,40
Chimney head cover
For flexpipe with junction pipe DN 110, stainless steel,
including fixings
F11 KAES 15 50 77.00 50 ** 329,40
F
l
u
e

g
a
s

s
y
s
t
e
m
69
70
Basic sets Type Order No. Price
Set F (A1 central roof heating)
LAS central heating plant, double-walled flue gas / supply air pipe DN 80 / 125 for A1 boiler
installation in roof space for room-air independent operation complete with seals, test adapter,
inspection pipe and roof penetration box (black) up to height of 3.0 m.
(installation version 5 and 6)
Attention: Please order roof covering separately.
SET-F 15 50 79.06 486,00
Set GCU1
Double-walled flue gas connection kit for all GCU compact for connection
to flue gas system components DN 80/125
SET-GCU1 15 50 79.17 169,00
Set L (GCU central roof heating)
LAS central heating plant in roof, double-walled flue gas / supply air pipe DN 80 / 125 for GCU
compact installation in roof space for room-air independent operation, complete with seals,
testadapter, inspection pipe and roof penetration box (black) up to height of 1.83 m.
(installation version 5 and 6)
Attention: Please order roof covering separately.
SET-L 15 50 79.10 314,15
Double-walled - white Type Order No. Price
Double-walled flue gas pipe DN 80 / 125
Powder-coated white RAL 9016
Length 250 mm D8 L25 15 50 79.01 02 39,80
Length 500 mm D8 L50 15 50 79.01 03 40,70
Length 1,000 mm D8 L100 15 50 79.01 04 59,55
Length 2,000 mm D8 L200 15 50 79.01 05 120,85
Double-walled flue gas elbow DN 80 / 125
Powder-coated white RAL 9016
15 D8 B15 15 50 79.00 19 56,80
30 D8 B30 15 50 79.00 20 56,80
45 D8 B45 15 50 79.01 01 56,80
87 D8 B87 15 50 79.01 00 57,60
Double-walled inspection pipe DN 80 / 125
Powder-coated white RAL 9016
D8 RR 15 50 79.00 99 103,00
Double-walled inspection elbow DN 80 / 125
Powder-coated white RAL 9016
D8 RB 15 50 79.00 98 103,55
Double-walled test adapter DN 80 / 125
Powder-coated white RAL 9016
D8 PA 15 50 79.00 93 74,60
Double-walled wall lead-through DN 80 / 125
With wall packing
D8 MD 15 50 79.01 13 40,80
Wall bracket for double-walled flue pipe DN 80 / 125
For indoors
D8 WH 15 50 79.00 62 17,85
Pitched roof collar
For roof penetration box DN 80 / 125,
5 25, universal,
black
D8 SD25S 15 50 79.00 14 68,30
25 45, universal,
black
D8 SD45S 15 50 79.00 37 68,30
35 55, universal,
black
D8 SD55S 15 50 79.00 12 68,30
A1, GSU compact room-air independent - as central heating plant in roof
DN 80 / 125, System No. 9
1)
with installation variant 1
2)
with installation variant 4
Flue gas system A1, GCU compact
F
l
u
e

g
a
s

s
y
s
t
e
m
71
Flue gas system A1, GCU compact
For additional accessory parts, see pages 84 93 ** Delivery period available on request.
Type Order No. Price
Flat roof covering
For roof penetration box DN 80 / 125
Aluminium,
120 mm high
D8 FD 15 50 79.00 40 63,60
0 15, Aluminium D8 FD15 15 50 79.00 82 81,50
Double-walled roof penetration
DN 80 / 125
400 mm over roof, incl.
rafter clip, black
D8 DF40S 15 50 79.00 36 138,65
400 mm over roof, incl.
rafter clip, red
D8 DF40R 15 50 79.00 38 138,65
1,000 mm over roof,
incl. rafter clip, black
D8 DF100S 15 50 79.00 76 173,35
1,000 mm over roof,
incl. rafter clip, red
D8 DF100R 15 50 79.00 77 173,35
F
l
u
e

g
a
s

s
y
s
t
e
m
*accessories if required
71
72
Basic sets Type Order No. Price
Set C
Straight double-walled connection line DN 80 / 125 between boiler and shaft
1)
/ wall
2)
,
complete with seals, test adapter and inspection pipe. (installation version 1 and 4)
SET-C 15 50 79.03 285,75
Set D
Double-walled connection line DN 80 / 125 for height offset connection between boiler and
shaft
1)
/ wall
2)
, complete with seals, test adapter and inspection elbow.
(installation version 1 and 4)
SET-D 15 50 79.04 387,70
Kit G
Double-walled external wall pipe DN 80 / 125, polished stainless steel casing pipe,
for room-air independent operation. Air is drawn in via external wall connection,
complete with seals up to height of 3.7 m, incl. 3 spacers. (installation version 4)
SET-G 15 50 79.07 621,95
Double-walled - white Type Order No. Price
Double-walled flue gas pipe DN 80 / 125
Powder-coated white RAL 9016
Length 250 mm D8 L25 15 50 79.01 02 39,80
Length 500 mm D8 L50 15 50 79.01 03 40,70
Length 1,000 mm D8 L100 15 50 79.01 04 59,55
Length 2,000 mm D8 L200 15 50 79.01 05 120,85
Double-walled flue gas elbow DN 80 / 125
Powder-coated white RAL 9016
45 D8 B45 15 50 79.01 01 56,80
87 D8 B87 15 50 79.01 00 57,60
Double-walled inspection pipe DN 80 / 125
Powder-coated white RAL 9016
D8 RR 15 50 79.00 99 103,00
Double-walled inspection elbow DN 80 / 125
Powder-coated white RAL 9016
D8 RB 15 50 79.00 98 103,55
Double-walled - stainless steel Type Order No. Price
Double-walled flue gas pipe DN 80 / 125
For the external area,
powder-coated white RAL 9016
Length 250 mm W8 L25 15 50 79.00 80 37,20
Length 500 mm W8 L50 15 50 79.00 74 48,65
Length 1,000 mm W8 L100 15 50 79.00 50 70,60
Length 2,000 mm W8 L200 15 50 79.00 81 129,80
Double-walled flue gas elbow DN 80 / 125
For outdoor use (polished stainless steel)
15 W8 B15 15 50 79.00 46 ** 61,40
30 W8 B30 15 50 79.00 47 61,40
45 W8 B45 15 50 79.00 48 61,40
87 W8 B87 15 50 79.00 49 73,35
Double-walled inspection pipe DN 80 / 125
For outdoor use (polished stainless steel)
W8 RR 15 50 79.01 14 111,35
Clamping strap
For external wall pipe DN 80 / 125, stainless steel
W8 KB 15 50 79.00 78 25,25
Wall holder
For external wall pipe DN 80 / 125, stainless steel
1 pieces. W8 WH 15 50 79.00 59 35,75
5 pieces. W8 WH5 15 50 79.00 75 173,35
A1 room-air independent - external wall flue gas pipe DN 80 / 125
System No. 10
A1 flue gas system
1)
with installation variant 1
2)
with installation variant 4 ** Delivery period available on request.
F
l
u
e

g
a
s

s
y
s
t
e
m
73
A1 flue gas system
For additional accessory parts, see pages 84 93
Type Order No. Price
*accessories if required
F
l
u
e

g
a
s

s
y
s
t
e
m
Extension wall holder for external wall pipe DN 80 / 125, stainless steel
For wall separation 43 137 mm
W8 WHV14 15 50 79.00 87 65,10
Extension for external wall bracket
For external wall connection DN 80 / 125
For wall distance 55 147 mm
W8 WKV15 15 50 79.00 84 72,55
External wall air inlet pipe DN 80 / 125
Polished stainless steel, including closing disc for external wall
connection
W8 ZR 15 50 79.00 66 149,15
Double-walled roof penetration box DN 80 / 125
For the external area, polished stainless steel, 400 mm over roof
W8 DF40 15 50 79.00 54 80,35
Pitched roof collar
For roof penetration box DN 80 / 125
5 25,
universal, black
D8 SD25S 15 50 79.00 14 68,30
25 45,
universal, black
D8 SD45S 15 50 79.00 37 68,30
35 55,
universal, black
D8 SD55S 15 50 79.00 12 68,30
Flat roof covering
For roof penetration box DN 80 / 125
Aluminium,
120 mm high
D8 FD 15 50 79.00 40 63,60
0 15, Aluminium D8 FD15 15 50 79.00 82 81,50
73
74
Basic sets Type Order No. Price
Set C
Straight double-walled connection line DN 80 / 125 between boiler and shaft
1)
/ wall
2)
,
complete with seals, test adapter and inspection pipe. (installation version 1 and 4)
SET-C 15 50 79.03 285,75
Set D
Double-walled connection line DN 80 / 125 for height offset connection between boiler and
shaft
1)
/ wall
2)
, complete with seals, test adapter and inspection elbow.
(installation version 1 and 4)
SET-D 15 50 79.04 387,70
Kit T
Double-walled external wall pipe DN 110 / 160, polished stainless steel casing pipe, for the
room-air independent mode. Air intake via external wall connection, complete with
seals up to height of 3.7 m, incl. 3 spacers. (installation version 4)
SET-T 15 50 77.04 ** 1.028,40
Double-walled - white Type Order No. Price
Double-walled flue gas pipe DN 80 / 125
Powder-coated white RAL 9016
Length 250 mm D8 L25 15 50 79.01 02 39,80
Length 500 mm D8 L50 15 50 79.01 03 40,70
Length 1,000 mm D8 L100 15 50 79.01 04 59,55
Length 2,000 mm D8 L200 15 50 79.01 05 120,85
Double-walled flue gas elbow DN 80 / 125
Powder-coated white RAL 9016
45 D8 B45 15 50 79.01 01 56,80
87 D8 B87 15 50 79.01 00 57,60
Double-walled inspection pipe DN 80 / 125
Powder-coated white RAL 9016
D8 RR 15 50 79.00 99 103,00
Double-walled inspection elbow DN 80 / 125
Powder-coated white RAL 9016
D8 RB 15 50 79.00 98 103,55
Double-walled - stainless steel Type Order No. Price
Double-walled flue gas pipe DN 100 / 160
For outdoor area, polished stainless steel
Length 500 mm W11 L50 15 50 77.00 23 ** 80,90
Length 1,000 mm W11 L100 15 50 77.00 22 ** 116,60
Length 2,000 mm W11 L200 15 50 77.00 21 ** 209,10
Double-walled inspection pipe DN 110 / 160
For outdoor area, polished stainless steel
W11 RR 15 50 77.00 28 ** 149,15
Clamping strap
For external wall pipe DN 110 / 160, stainless steel
W11 KB 15 50 77.00 34 ** 40,50
Wall support
For external wall pipe DN 110 / 160, stainless steel, 1 in number
W11 WH 15 50 77.00 31 ** 50,00
Wall holder extension
For external wall pipe DN 110 / 160,
stainless steel
For wall distance
67 - 163 mm
W11 WHV17 15 50 77.00 83 ** 73,90
For wall distance
171 - 286 mm
W11 WHV29 15 50 77.00 84 ** 89,95
For wall distance
287 - 402 mm
W11 WHV40 15 50 77.00 85 ** 100,15
A1 room-air independent - external wall flue gas pipe DN 110 / 160
System No. 11
A1 flue gas system
1)
with installation variant 1
2)
with installation variant 4 ** Delivery period available on request.
F
l
u
e

g
a
s

s
y
s
t
e
m
75
For additional accessory parts, see pages 84 93
A1 flue gas system
Type Order No. Price
Extension
For external wall bracket for
external wall connection DN 110 / 160
For wall distance
61 - 181 mm
W11 WKV18 15 50 77.00 69 ** 152,75
For wall distance
186 - 273 mm
W11 WKV27 15 50 77.00 81 ** 191,60
For wall distance
277 - 364 mm
W11 WKV36 15 50 77.00 82 ** 295,65
External wall air inlet pipe DN 110 / 160
Polishes stainless steel,
including closing disc for external wall connection
W11 ZR 15 50 77.00 30 ** 182,85
Double-walled roof penetration box DN 110 / 160
For outdoor use (polished stainless steel),
1,000 mm above roof
W11 DF100 15 50 77.00 32 ** 297,40
Pitched roof collar
For roof penetration box DN 110 / 160
5 25,
universal, black
D11 SD25S 15 50 77.00 70 ** 124,25
25 45,
universal, black
D11 SD45S 15 50 77.00 35 ** 120,35
Flat roof cover
For roof penetration box DN 110 / 160,
Aluminium, 130 mm high
D11 FD 15 50 77.00 37 ** 85,60
*accessories if required
F
l
u
e

g
a
s

s
y
s
t
e
m
75
76
Basic sets Type Order No. Price
Set H
Double-walled connecting pipe DN 80 / 125 between GSU compact and shaft
1)
/ wall
2)

for flue gas connection to the rear, for room-air independent operation, complete with seals,
testadapter and inspection pipe. (installation version 1 and 4)
SET-H 15 50 79.08 294,20
Set K
Double-walled connecting pipe DN 80 / 125 between GSU compact and shaft
1)
/

wall
2)

for flue gas connection at side, for room-air independent operation, complete with seals,
testadapter and inspection bend. (installation version 1 and 4)
SET-K 15 50 79.09 347,00
Kit G
Double-walled external wall pipe DN 80 / 125, polished stainless steel casing pipe,
for the room-air independent mode. Air intake via external wall connection,
complete with seals up to height of 3.7 m, incl. 3 spacers. (installation version 4)
SET-G 15 50 79.07 621,95
Double-walled - white Type Order No. Price
Double-walled flue gas pipe DN 80 / 125
Powder-coated white RAL 9016
Length 250 mm D8 L25 15 50 79.01 02 39,80
Length 500 mm D8 L50 15 50 79.01 03 40,70
Length 1,000 mm D8 L100 15 50 79.01 04 59,55
Length 2,000 mm D8 L200 15 50 79.01 05 120,85
Double-walled flue gas elbow DN 80 / 125
Powder-coated white RAL 9016
45 D8 B45 15 50 79.01 01 56,80
87 D8 B87 15 50 79.01 00 57,60
Double-walled inspection pipe DN 80 / 125
Powder-coated white RAL 9016
D8 RR 15 50 79.00 99 103,00
Double-walled inspection elbow DN 80 / 125
Powder-coated white RAL 9016
D8 RB 15 50 79.00 98 103,55
Double-walled - stainless steel Type Order No. Price
Double-walled flue gas pipe DN 80 / 125
For the external area
powder-coated white RAL 9016
Length 250 mm W8 L25 15 50 79.00 80 37,20
Length 500 mm W8 L50 15 50 79.00 74 48,65
Length 1,000 mm W8 L100 15 50 79.00 50 70,60
Length 2,000 mm W8 L200 15 50 79.00 81 129,80
Double-walled flue gas elbow DN 80 / 125
For outdoor area, polished stainless steel
15 W8 B15 15 50 79.00 46 ** 61,40
30 W8 B30 15 50 79.00 47 61,40
45 W8 B45 15 50 79.00 48 61,40
87 W8 B87 15 50 79.00 49 73,35
Double-walled inspection pipe DN 80 / 125
For outdoor area, polished stainless steel
W8 RR 15 50 79.01 14 111,35
Clamping strap
For external wall pipe DN 80 / 125, stainless steel
W8 KB 15 50 79.00 78 25,25
Wall holder
For external wall pipe DN 80 / 125, stainless steel
1 pieces. W8 WH 15 50 79.00 59 35,75
5 pieces. W8 WH5 15 50 79.00 75 173,35
GCU compact room-air independent - external wall flue gas pipe DN 80 / 125
System No. 12
Flue gas system GCU compact
1)
with installation variant 1
2)
with installation variant 4
F
l
u
e

g
a
s

s
y
s
t
e
m
77
Flue gas system GCU compact
For additional accessory parts, see pages 84 93
Type Order No. Price
Wall holder extension
For external wall pipe DN 80 / 125, for wall distance 43 137 mm,
stainless steel
W8 WHV14 15 50 79.00 87 65,10
Extension for external wall bracket for external wall connection
DN 80 / 125 for wall distance 55 147 mm
W8 WKV15 15 50 79.00 84 72,55
External wall air inlet pipe DN 80 / 125
Including closing disc for external wall connection, stainless steel
W8 ZR 15 50 79.00 66 149,15
Double-walled roof penetration box DN 80 / 125
For the external area, 400 mm over roof, polished stainless steel
W8 DF40 15 50 79.00 54 80,35
Pitched roof collar
For roof penetration box DN 80 / 125
5 25,
universal, black
D8 SD25S 15 50 79.00 14 68,30
25 45,
universal, black
D8 SD45S 15 50 79.00 37 68,30
35 55,
universal, black
D8 SD55S 15 50 79.00 12 68,30
Flat roof cover
For roof penetration box DN 80 / 125,
120 mm high,
Aluminium
D8 FD 15 50 79.00 40 63,60
0 15, Aluminium D8 FD15 15 50 79.00 82 81,50
F
l
u
e

g
a
s

s
y
s
t
e
m
*accessories if required
77
78
Basic sets Type Order No. Price
Set H
Double-walled connecting pipe DN 80 / 125 between GSU compact and shaft
1)
/ wall
2)

for flue gas connection to the rear, for room-air independent operation, complete with seals,
test adapter and inspection pipe. (installation version 1 and 4)
SET-H 15 50 79.08 294,20
Set K
Double-walled connecting pipe DN 80 / 125 between GSU compact and shaft
1)
/ wall
2)

for flue gas connection at side, for room-air independent operation, complete with seals,
test adapter and inspection bend. (installation version 1 and 4)
SET-K 15 50 79.09 347,00
Kit T
Double-walled external wall pipe DN 110 / 160, polished stainless steel casing pipe,
for room-air independent operation. Air is drawn in via external wall connection,
complete with seals up to height of 3.7 m, incl. 3 spacers. (installation version 4)
SET-T 15 50 77.04 **1.028,40
Double-walled - white Type Order No. Price
Double-walled flue gas pipe DN 80 / 125
Powder-coated white RAL 9016
Length 250 mm D8 L25 15 50 79.01 02 39,80
Length 500 mm D8 L50 15 50 79.01 03 40,70
Length 1,000 mm D8 L100 15 50 79.01 04 59,55
Length 2,000 mm D8 L200 15 50 79.01 05 120,85
Double-walled flue gas elbow DN 80 / 125
Powder-coated white RAL 9016
15 D8 B15 15 50 79.00 19 56,80
30 D8 B30 15 50 79.00 20 56,80
45 D8 B45 15 50 79.01 01 56,80
87 D8 B87 15 50 79.01 00 57,60
Double-walled inspection pipe DN 80 / 125
Powder-coated white RAL 9016
D8 RR 15 50 79.00 99 103,00
Double-walled inspection elbow DN 80 / 125
Powder-coated white RAL 9016
D8 RB 15 50 79.00 98 103,55
Double-walled test adapter DN 80 / 125
Powder-coated white RAL 9016
D8 PA 15 50 79.00 93 74,60
Double-walled wall lead-through
DN 80 / 125
With wall sleeve
D8 MD 15 50 79.01 13 40,80
Wall holder
For double-walled flue gas pipe DN 80 / 125,
for the internal area
D8 WH 15 50 79.00 62 17,85
Double-walled - stainless steel Type Order No. Price
Double-walled flue gas pipe DN 110 / 160
For outdoor area, polished stainless steel
Length 500 mm W11 L50 15 50 77.00 23 **80,90
Length 1,000 mm W11 L100 15 50 77.00 22 **116,60
Length 2,000 mm W11 L200 15 50 77.00 21 **209,10
Clamping strap
For external wall pipe DN 110 / 160,
stainless steel
W11 KB 15 50 77.00 34 **40,50
Wall holder
For external wall pipe DN 110 / 160,
stainless steel, 1 in number
W11 WH 15 50 77.00 31 **50,00
GCU compact room-air independent - external wall flue gas pipe DN 110 / 160
System No. 13
Flue gas system GCU compact
1)
with installation variant 1
2)
with installation variant 4 ** delivery period on request. For additional accessory parts, see pages 84 93.
F
l
u
e

g
a
s

s
y
s
t
e
m
79
Accessories Description Type Order No. Price
Wall holder extension
For external wall pipe DN 110 / 160, stainless steel
For wall distance
67 163 mm
W11 WHV17 15 50 77.00 83 **73,90
For wall distance
171 286 mm
W11 WHV29 15 50 77.00 84 **89,95
For wall distance
287 402 mm
W11 WHV40 15 50 77.00 85 **100,15
Extension for external wall bracket
For external wall connection DN 110 / 160
For wall distance
61 181 mm
W11 WKV18 15 50 77.00 69 **152,75
For wall distance
186 273 mm
W11 WKV27 15 50 77.00 81 **191,60
For wall distance
277 364 mm
W11 WKV36 15 50 77.00 82 **295,65
External wall air inlet pipe DN 110 / 160
Including closing disc for external wall
connection, stainless steel
W11 ZR 15 50 77.00 30 **182,85
Double-walled roof transition
DN 110 / 160
For theexternal area, 1000 mm over the roof,
Polished stainless steel
W11 DF100 15 50 77.00 32 **297,40
Pitched roof collar
For roof penetration box DN 110 / 160
5 25,
universal, black
D11 SD25S 15 50 77.00 70 **124,25
25 45,
universal, black
D11 SD45S 15 50 77.00 35 **120,35
Pitched roof collar
For roof penetration box DN 110 / 160
Aluminium,
130 mm high
D11 FD 15 50 77.00 37 **85,60
Flue gas system GCU compact
*Delivery period on request Additional accessories can be seen on pages 84 93
F
l
u
e

g
a
s

s
y
s
t
e
m
*accessories if required
79
80
Basic sets Type Order No. Price
Set GW1
Double-wall connection line DN 80 / 125 between GW and duct
1)
/ wall
2)
for flue gas connection to
the rear or to the side, for room-air independent operation, complete with seals and inspection
elbows. (installation version 1 and 4)
SET GW1 15 50 79.15 289,00
Kit E
Single wall flue gas pipe DN 80 for installation in fire resistant shaft complete with
seals, chimney support, chimney head cover, length 10 m including spacers.
(installation version 1, 2 and 3)
SET-E 15 50 79.05 279,00
Kit O
Single-walled flexible flue gas pipe DN 80 for installation in fire-resistant shaft,
complete with seals, chimney support, chimney head cover and connection piece,
Length up to 12.7 m including spacers (installation version 1, 2 and 3)
SET-O 15 50 79.13 695,50
Double-walled - white Type Order No. Price
Double-walled flue gas pipe DN 80 / 125
Powder-coated white RAL 9016
Length 250 mm D8 L25 15 50 79.01 02 39,80
Length 500 mm D8 L50 15 50 79.01 03 40,70
Length 1,000 mm D8 L100 15 50 79.01 04 59,55
Length 2,000 mm D8 L200 15 50 79.01 05 120,85
Double-walled flue gas elbow DN 80 / 125
Powder-coated white RAL 9016
15 D8 B15 15 50 79.00 19 56,80
30 D8 B30 15 50 79.00 20 56,80
45 D8 B45 15 50 79.01 01 56,80
87 D8 B87 15 50 79.01 00 57,60
Double-walled inspection pipe DN 80 / 125
Powder-coated white RAL 9016
D8 RR 15 50 79.00 99 103,00
Double-walled inspection elbow DN 80 / 125
Powder-coated white RAL 9016
D8 RB 15 50 79.00 98 103,55
Double-walled test adapter DN 80 / 125 for GW
Powder coated white, installation height 120 mm
D8 PA-GW 15 50 79.01 43 149,00
Double-walled wall lead-through DN 80 / 125
With wall sleeve
D8 MD 15 50 79.01 13 40,80
Wall bracket for double-walled flue pipe DN 80 / 125
For indoors
D8 WH 15 50 79.00 62 17,85
Double-walled reducer DN 80 / 125
To DN 60 / 100, Sleeve DN 80 / 125
D6 / 8 Z 15 50 79.01 44 99,00
Single-walled Type Order No. Price
Single-walled flue gas pipe DN 80 Length 250 mm E8 L25 15 50 79.00 73 16,70
Length 500 mm E8 L50 15 50 79.00 72 19,90
Length 1,000 mm E8 L100 15 50 79.00 71 24,55
Length 2,000 mm E8 L200 15 50 79.00 70 35,45
Single-walled flue gas elbow DN 80

15 E8 B15 15 50 79.00 11 15,05
30 E8 B30 15 50 79.00 13 15,05
45 E8 B45 15 50 79.01 09 11,55
87 E8 B87 15 50 79.01 08 11,55
GW room-air independent - rigid and flexible flue gas line DN 80 in shaft
System No. 14
1)
with installation variant 1
2)
with installation variant 4
F
l
u
e

g
a
s

s
y
s
t
e
m
Flue gas system GW
81
*accessories if required
Type Order No. Price
Single-walled inspection pipe DN 80 E8 RR 15 50 79.01 07 46,15
Spacer kit DN 80
6 pieces.
E8 AH 15 50 79.00 30 42,45
Flue gas opening noise damper DN 80
Suitable for all mouth moulds apart from flexible shaft pipes
E8 MSD 15 45 78 89,00
Flexible DN 80 Type Order No. Price
Flexible flue gas pipe DN 80 Length 12.5 m F8 L1250 15 50 79.00 31 394,70
Length 25 m F8 L2500 15 50 79.00 32 787,95
Length 50 m F8 L5000 15 50 79.00 33 ** 1.575,90
Spacer kit DN 80
6 pieces.
E8 AH 15 50 79.00 30 42,45
Inspection pipe DN 80
For flexible flue gas pipe
F8 RR 15 50 79.00 63 155,55
Installation aid DN 80
For flexible flue gas pipe with 20 m rope
F8 MH 15 50 79.00 44 128,15
Coupling
For flexible flue pipe DN 80
F8 K 15 50 79.00 61 128,75
Connection sleeve DN 80
For transition from flexible to rigid flue pipe
F8 VM 15 50 79.00 34 61,50
Chimney head cover
For flexpipe with junction pipe DN 80, including fixings,
stainless steel
F8 KAES 15 50 79.01 32 ** 232,25
For additional accessory parts, see pages 84 93
F
l
u
e

g
a
s

s
y
s
t
e
m
Flue gas system GW
81
82
Basic sets Type Order No. Price
Set GW1
Double-walled connecting pipe DN 80 / 125 between GW and shaft
1)
/ wall
2)
for
Flue gas connection to the rear or to the side, for room-air independent operation,
complete with seals and inspection elbows. (installation version 1 and 4)
SET GW1 15 50 79.15 289,00
Kit GW2
LAS roof heating centre, double-walled flue gas / Air inlet pipe DN 80 / 125 for GW installation
in the roof for operation independent of room air, complete with seals, inspection pipe and
roof penetration (black), height up to 1.8 m (installation variant 5 and 6).
Attention: Please order roof covering separately.
SET GW2 15 50 79.16 319,00
Kit G
Double-walled external wall pipe DN 80 / 125, polished stainless steel casing pipe, for room-air
independent operation. Air inlet via external wall connection, complete with seals up to 3.7 m
height, including 3 spacers (installation variant 4)
SET-G 15 50 79.07 621,95
Double-walled - white Type Order No. Price
Double-walled flue gas pipe DN 80 / 125
Powder-coated white RAL 9016
Length 250 mm D8 L25 15 50 79.01 02 39,80
Length 500 mm D8 L50 15 50 79.01 03 40,70
Length 1,000 mm D8 L100 15 50 79.01 04 59,55
Length 2,000 mm D8 L200 15 50 79.01 05 120,85
Double-walled flue gas elbow DN 80 / 125
Powder-coated white RAL 9016
45 D8 B45 15 50 79.01 01 56,80
87 D8 B87 15 50 79.01 00 57,60
Double-walled inspection pipe DN 80 / 125
Powder-coated white RAL 9016
D8 RR 15 50 79.00 99 103,00
Double-walled inspection elbow DN 80 / 125
Powder-coated white RAL 9016
D8 RB 15 50 79.00 98 103,55
Double-walled reducer DN 80 / 125
To DN 60 / 100, Sleeve DN 80 / 125
D6 / 8 Z 15 50 79.01 44 99,00
Double-walled - stainless steel Type Order No. Price
Double-walled flue gas pipe DN 80 / 125
For the external area,
powder-coated white RAL 9016
Length 250 mm W8 L25 15 50 79.00 80 37,20
Length 500 mm W8 L50 15 50 79.00 74 48,65
Length 1,000 mm W8 L100 15 50 79.00 50 70,60
Length 2,000 mm W8 L200 15 50 79.00 81 129,80
Double-walled flue gas elbow DN 80 / 125
For the external area, polished stainless steel
15 W8 B15 15 50 79.00 46 ** 61,40
30 W8 B30 15 50 79.00 47 61,40
45 W8 B45 15 50 79.00 48 61,40
87 W8 B87 15 50 79.00 49 73,35
Double-walled inspection pipe DN 80 / 125
For outdoor area, polished stainless steel
W8 RR 15 50 79.01 14 111,35
Clamping strap for external wall pipe DN 80 / 125
Stainless steel
W8 KB 15 50 79.00 78 25,25
Wall holder for external wall pipe
DN80 / 125
Stainless steel
1 pieces. W8 WH 15 50 79.00 59 35,75
5 pieces. W8 WH5 15 50 79.00 75 173,35
GW room-air independent - external wall flue gas line / Roof heating centre
DN 80 / 125 System No. 15
Flue gas system GW
1)
with installation variant 1
2)
with installation variant 4 ** Delivery period available on request.
F
l
u
e

g
a
s

s
y
s
t
e
m
83
Flue gas system GW
For additional accessory parts, see pages 84 93
Type Order No. Price
Extension wall holder for external wall pipe DN 80 / 125
For wall separation 43 137 mm, stainless steel
W8 WHV14 15 50 79.00 87 65,10
Extension for external wall bracket
For external wall connection DN 80 / 125
For wall distance 55 147 mm
W8 WKV15 15 50 79.00 84 72,55
External wall air inlet pipe DN 80 / 125
Including closing disc for external wall connection, polished stainless
steel
W8 ZR 15 50 79.00 66 149,15
Double-walled roof penetration box DN 80 / 125
For the external area, 400 mm over roof, polished stainless steel
W8 DF40 15 50 79.00 54 80,35
Pitched roof collar
For roof penetration box DN 80 / 125
5 25,
universal, black
D8 SD25S 15 50 79.00 14 68,30
25 45,
universal, black
D8 SD45S 15 50 79.00 37 68,30
35 55,
universal, black
D8 SD55S 15 50 79.00 12 68,30
Flat roof cover for roof penetration
DN 80 / 125,
Aluminium,
120 mm high
D8 FD 15 50 79.00 40 63,60
0 15, Aluminium D8 FD15 15 50 79.00 82 81,50
*accessories if required
F
l
u
e

g
a
s

s
y
s
t
e
m
83
84
Description Type Order No. Price
Single-walled flue gas pipe DN 80 Length 250 mm E8 L25 15 50 79.00 73 16,70
Length 500 mm E8 L50 15 50 79.00 72 19,90
Length 1,000 mm E8 L100 15 50 79.00 71 24,55
Length 2,000 mm E8 L200 15 50 79.00 70 35,45
Single-walled flue gas elbow DN 80 15 E8 B15 15 50 79.00 11 15,05
30 E8 B30 15 50 79.00 13 15,05
45 E8 B45 15 50 79.01 09 11,55
87 E8 B87 15 50 79.01 08 11,55
Single-walled inspection pipe DN 80 E8 RR 15 50 79.01 07 46,15
Single-walled inspection elbow DN 80 E8 RB 15 50 79.01 06 46,15
Single-walled test adapter DN 80 E8 PA 15 50 70.00 52 35,65
Chimney support DN 80
Flue gas elbow 87 and support plate with
support rail
E8 ST 15 50 79.01 11 43,60
Ventilation grid with fly protection
White, for covering the back-ventilation
opening
E0 LG 15 50 79.00 91 29,05
Junction pipe DN 80
Black
Length 500 mm E8 L50S 15 50 79.00 68 15,75
Chimney head covering
With junction pipe DN 80
Black, including
Fixing materials
E8 KAS 15 50 79.00 67 90,25
Stainless steel,
including.
installation material
E8 KAES 15 50 79.00 79 236,40
Spacer set DN 80
6 in number
E8 AH 15 50 79.00 30 42,45
Cover panel for chimney flue
Single-walled flue gas pipe DN 80
E8 AB 15 50 79.00 29 **27,30
Flue gas opening noise damper DN 80
Suitable for all mouth moulds apart from
flexible shaft pipes
E8 MSD 15 45 78 89,00
Air supply noise damper
For A1 boiler with room-air dependent
Operating mode
G ZLSD 15 45 77 49,00
Single-walled components DN 80
E1
Flue gas system accessories: Individual components
** Delivery period available on request.
F
l
u
e

g
a
s

s
y
s
t
e
m
85
Description Type Order No. Price
Single-walled flue gas pipe DN 110 Length 250 mm E11 L25 15 50 77.00 04 30,50
Length 500 mm E11 L50 15 50 77.00 03 39,30
Length 1,000 mm E11 L100 15 50 77.00 02 43,20
Length 2,000 mm E11 L200 15 50 77.00 01 50,30
Single-walled inspection pipe DN 110 E121 RR 15 50 77.00 09 67,10
Chimney support DN 110
Flue gas elbow 87 and support plate with
support rail
E11 ST 15 50 77.00 10 60,60
Ventilation grid with fly protection
White, for covering the back-ventilation
opening
E0 LG 15 50 79.00 91 29,05
Junction pipe DN 110
Black
Length 500 mm E11 L50S 15 50 77.00 15 **22,05
Chimney head covering
With junction pipe DN 110
Black, including
installation material
E11 KAS 15 50 77.00 12 116,10
Stainless steel,
including.
installation material
E11 KAES 15 50 77.00 14 204,90
Spacer kit DN 110
6 pieces.
F11 AH 15 50 77.00 13 59,75
Flue gas opening noise damper DN 110
Suitable for all mouth moulds apart from
flexible shaft pipes
E11 MSD 15 45 79 176,00
Single-walled reducer
from DN 110 to DN 80
Eccentric,
Sleeve DN 110
E8 / 11 EX 15 50 77.00 17 ** 55,75
Central,
Sleeve DN 110
E8 / 11 Z 15 50 77.00 16 ** 53,60
Lubricant G GM 15 50 79.00 42 4,75
Single-walled components DN 80
E1
Flue gas system accessories: Individual components
** Delivery period available on request.
F
l
u
e

g
a
s

s
y
s
t
e
m
Description Type Order No. Price
Single-walled reducer
from DN 110 to DN 80
Eccentric,
Sleeve DN 110
E8 / 11 EX 15 50 77.00 17 **55,75
Central,
Sleeve DN 110
E8 / 11 Z 15 50 77.00 16 **53,60
Lubricant G GM 15 50 79.00 42 4,75
Single-walled components DN 110
E2
85
86
Description Type Order No. Price
Double-walled flue gas pipe DN 80 / 125
Powder-coated white RAL 9016
Length 250 mm D8 L25 15 50 79.01 02 39,80
Length 500 mm D8 L50 15 50 79.01 03 40,70
Length 1,000 mm D8 L100 15 50 79.01 04 59,55
Length 2,000 mm D8 L200 15 50 79.01 05 120,85
Double-walled flue gas elbow DN 80 / 125
Powder-coated white RAL 9016
15 D8 B15 15 50 79.00 19 56,80
30 D8 B30 15 50 79.00 20 56,80
45 D8 B45 15 50 79.01 01 56,80
87 D8 B87 15 50 79.01 00 57,60
Double-walled inspection pipe DN 80 / 125
Powder-coated white RAL 9016
D8 RR 15 50 79.00 99 103,00
Double-walled inspection elbow DN 80 / 125
Powder-coated white RAL 9016
D8 RB 15 50 79.00 98 103,55
Double-walled test adapter DN 80 / 125
Powder-coated white RAL 9016
D8 PA 15 50 79.00 93 74,60
Double-walled test adapter DN 80 / 125
For GW, powder coated white,
Fitting height 120 mm
PA-GW 15 50 79.01 43 149,00
Double-walled roof penetration DN 80 / 125
400 mm over roof, including rafter clamp
black D8 DF40S 15 50 79.00 36 138,65
red D8 DF40R 15 50 79.00 38 138,65
Double-walled roof penetration DN 80 / 125
1,000 mm over roof, including rafter clamp
black D8 DF100S 15 50 79.00 76 173,35
red D8 DF100R 15 50 79.00 77 173,35
Sloping roof tile
For roof penetration box DN 80 / 125
5 25, universal,
black
D8 SD25S 15 50 79.00 14 68,30
5 25, universal,
red
D8 SD25R 15 50 79.01 17 **68,30
25 45, universal,
black
D8 SD45S 15 50 79.00 37 68,30
25 45, universal,
red
D8 SD45R 15 50 79.00 39 68,30
35 55, universal,
black
D8 SD55S 15 50 79.00 12 68,30
35 55, universal,
red
D8 SD55R 15 50 79.01 18 **68,30
Double-walled components DN 80 / 125
E3
Flue gas system accessories: Individual components
** Delivery period available on request.
F
l
u
e

g
a
s

s
y
s
t
e
m
87
Description Type Order No. Price
Flat roof covering
For roof penetration box DN 80 / 125
Aluminium,
120 mm high
D8 FD 15 50 79.00 40 63,60
Aluminium,
250 mm high
D8 FDH 15 50 79.01 40 **86,85
0 - 15, Aluminium D8 FD15 15 50 79.00 82 81,50
Double-walled wall lead-through
DN 80 / 125
With wall sleeve
D8 MD 15 50 79.01 13 40,80
Double-walled wall lead-through
Extension eccentric DN 80 / 125 to
DN 110 / 160
D8 / 11 MD 15 50 77.00 39 ** 146,70
Double-walled reducer
From DN 110 / 160 to DN 80 / 125 central,
Sleeve DN 110 / 160
D8 / 11 Z 15 50 77.00 60 ** 148,65
Double-walled reducer
From DN 80 / 100 to DN 60 / 100
Sleeve DN 80 / 125
D6 / 8 Z 15 50 79.01 44 99,00
Wall support
For double-walled flue gas pipe DN 80 / 125,
for indoors
D8 WH 15 50 79.00 62 17,85
Cover panel for chimney flue
Wall lead-through DN 80 / 125,
powder coated white RAL 9016
D8 AB 15 50 79.00 28 30,50
Two-piece cover panel for chimney flue
Inclined wall lead-through DN 80 / 125
- 0 to 45
powder coated white RAL 9016
D8 AB45 15 50 79.00 83 ** 30,50
Lubricant G GM 15 50 79.00 42 4,75
Double-walled components DN 80 / 125
E3
Flue gas system accessories: Individual components
** Delivery period available on request.
F
l
u
e

g
a
s

s
y
s
t
e
m
87
88
Description Type Order No. Price
Double-walled flue gas pipe DN 110 / 160
Powder-coated white RAL 9016
Length 500 mm D11 L50 15 50 77.00 59 **66,35
Length 1,000 mm D11 L100 15 50 77.00 86 **103,35
Length 2,000 mm D11 L200 15 50 77.00 87 **201,40
Double-walled flue gas elbow DN 110 / 160
Powder-coated white RAL 9016
15 D11 B15 15 50 77.00 72 **77,80
30 D11 B30 15 50 77.00 73 **77,80
45 D11 B45 15 50 77.00 74 **77,80
87 D11 B87 15 50 77.00 75 ** 91,10
Double-walled inspection pipe DN 110 / 160
Powder-coated white RAL 9016
D11 RR 15 50 77.00 76 **134,35
Double-walled inspection elbow DN 110 / 160
Powder-coated white RAL 9016
D11 RB 15 50 77.00 77 **144,95
Double-walled roof penetration
DN 110 / 160,
1000 mm over roof, including rafter clamp
Black D11 DF100S 15 50 77.00 78 **330,65
Red D11 DF100R 15 50 77.00 79 **330,65
Pitched roof collar
For roof penetration DN 110 / 160
5 25, universal,
black
D11 SD25S 15 50 77.00 70 **124,25
5 25, universal,
red
D11 SD25R 15 50 77.00 71 **124,25
25 45, universal,
black
D11 SD45S 15 50 77.00 35 **120,35
25 45, universal,
red
D11 SD45R 15 50 77.00 36 **120,35
Flat roof cover
For roof penetration DN 110 / 160
Aluminium,
130 mm high
D11 FD 15 50 77.00 37 **85,60
0 15, Aluminium D11 FD15 15 50 77.00 80 **107,15
Double-walled wall lead-through
DN 110 / 160
With wall sleeve
D11 MD 15 50 77.00 67 **89,00
Double-walled wall lead-through
Eccentric extension DN 80 / 125 to DN 110 / 160
D8 / 11 MD 15 50 77.00 39 **146,70
Double-walled components DN 110 / 160
E4
Flue gas system accessories: Individual components
** Delivery period available on request.
F
l
u
e

g
a
s

s
y
s
t
e
m
89
Flue gas system accessories: Individual components
** Delivery period available on request.
Description Type Order No. Price
Double-walled reducer from DN 110 / 160 to
DN 80 / 125 central,
Sleeve DN 110 / 160
D8 / 11 Z 15 50 77.00 60 **148,65
Lubricant G GM 15 50 79.00 42 4,75
Double-walled components DN 110 / 160
E4
Components for use outdoors (stainless steel) DN 80 / 125
E5
Description Type Order No. Price
Double-walled flue gas pipe DN 80 / 125 Length 250 mm W8 L25 15 50 79.00 80 37,20
For outdoor area, polished stainless steel
Length 500 mm W8 L50 15 50 79.00 74 48,65
Length 1,000 mm W8 L100 15 50 79.00 50 70,60
Length 2,000 mm W8 L200 15 50 79.00 81 129,80
Double-walled flue gas elbow DN 80 / 125
For outdoor area, polished stainless steel
15 W8 B15 15 50 79.00 46 **61,40
30 W8 B30 15 50 79.00 47 61,40
45 W8 B45 15 50 79.00 48 61,40
87 W8 B87 15 50 79.00 49 73,35
Double-walled inspection pipe DN 80 / 125,
For outdoor area, polished stainless steel
W8 RR 15 50 79.01 14 111,35
External wall air inlet pipe DN 80 / 125,
For external wall connection, including
closing disc, polished stainless steel
W8 ZR 15 50 79.00 66 149,15
Double-walled roof penetration
DN 80 / 125 for the external area
400 mm over roof, polished stainless steel
W8 DF40 15 50 79.00 54 80,35
External wall junction close-off
DN 80 / 125
With junction pipe and clamping strap,
Polished stainless steel
W8 MA 15 50 79.00 56 96,65
Clamping strap for external wall pipe DN
80 / 125, stainless steel
W8 KB 15 50 79.00 78 25,25
Double-walled external wall connection
DN 80 / 125
Including wall bracket, polished stainless steel
W8 WK 15 50 79.00 53 180,70
F
l
u
e

g
a
s

s
y
s
t
e
m
89
90
Description Type Order No. Price
Extension for external wall bracket
For external wall connection DN 80 / 125
For wall distance
55 147 mm
W8 WKV15 15 50 79.00 84 72,55
For wall distance
147 239 mm
W8 WKV24 15 50 79.00 85 110,35
For wall distance
239 331 mm
W8 WKV33 15 50 79.00 86 127,15
Wall holder for external wall pipe
DN 80 / 125
Stainless steel
1 pieces. W8 WH 15 50 79.00 59 35,75
5 pieces. W8 WH5 15 50 79.00 75 173,35
Extension wall holder
For external wall pipe DN 80 / 125,
stainless steel
For wall distance
43 137 mm
W8 WHV14 15 50 79.00 87 65,10
For wall distance
137 231 mm
W8 WHV23 15 50 79.00 88 78,80
For wall distance
231 325 mm
W8 WHV32 15 50 79.00 89 87,60
Cover screen for external wall
Roof penetration DN 80 / 125,
Polished stainless steel
W8 AB 15 50 79.00 58 27,10
Two-piece cover screen for external wall
Inclined lead-through DN 80 / 125 - 0 to 45 -
polished stainless steel
W8 AB45 15 50 79.01 39 **67,60
Lubricant G GM 15 50 79.00 42 4,75
Components for use outdoors (stainless steel) DN 80 / 125
E5
Flue gas system accessories: Individual components
** Delivery period available on request.
F
l
u
e

g
a
s

s
y
s
t
e
m
91
Description Type Order No. Price
Double-walled flue gas pipe DN 110 / 160
For outdoor area, polished stainless steel
Length 500 mm W11 L50 15 50 77.00 23 **80,90
Length 1,000 mm W11 L100 15 50 77.00 22 **116,60
Length 2,000 mm W11 L200 15 50 77.00 21 **209,10
Double-walled flue gas elbow DN 110 / 160
For outdoor area, polished stainless steel
15 W11 B15 15 50 77.00 24 **103,55
30 W11 B30 15 50 77.00 25 **103,55
45 W11 B45 15 50 77.00 26 **103,55
87 W11 B87 15 50 77.00 27 **110,35
Double-walled inspection pipe DN 110 / 160
For outdoor area, polished stainless steel
W11 RR 15 50 77.00 28 **149,15
External wall air inlet pipe DN 110 / 160,
For external wall connection, including clos-
ing disc, polished stainless steel
W11 ZR 15 50 77.00 30 **182,85
Double-walled roof penetration
DN 110 / 160
For the external area, 1000 mm over roof,
polished stainless steel
W11 DF100 15 50 77.00 32 **297,40
External wall junction close-off
DN 110 / 160
With junction pipe and clamping strap
Polished stainless steel
W11 MA 15 50 77.00 33 **127,65
Clamping strap for external wall pipe
DN110 / 160 Stainless steel
W11 KB 15 50 77.00 34 **40,50
Double-walled wall lead-through
Extension eccentric DN 80 / 125 to
DN 110 / 160
D8 / 11 MD 15 50 77.00 39 **146,70
Double-walled external wall connection
DN 110 / 160
Including wall bracket, polished stainless steel
W11 WK 15 50 77.00 29 **272,65
Extension for external wall bracket
For external wall connection DN 110 / 160
For wall distance
61 181 mm
W11 WKV18 15 50 77.00 69 **152,75
For wall distance
186 273 mm
W11 WKV27 15 50 77.00 81 **191,60
For wall distance
277 364 mm
W11 WKV36 15 50 77.00 82 **295,65
Components for use outdoors (stainless steel) DN 110 / 160
E6
Flue gas system accessories: Individual components
** Delivery period available on request.
F
l
u
e

g
a
s

s
y
s
t
e
m
91
92
Flue gas system accessories: Individual components
Description Type Order No. Price
Wall holder
For external wall pipe DN 110 / 160,
Stainless steel
1 pieces. W11 WH 15 50 77.00 31 **50,00
Extension wall holder
For external wall pipe DN 110 / 160,
Stainless steel
For wall distance
67 163 mm
W11 WHV17 15 50 77.00 83 **73,90
For wall distance
171 268 mm
W11 WHV29 15 50 77.00 84 **89,95
For wall distance
287 402 mm
W11 WHV40 15 50 77.00 85 **100,15
Cover screen for external wall
Penetration DN 110 / 160 - Polished stainless
steel
W11 AB 15 50 81.00 05 36,70
Lubricant G GM 15 50 79.00 42 4,75
Components for use outdoors (stainless steel) DN 110 / 160
E6
Components for flexible flue gas pipe in shaft DN 80
E7
** Delivery period available on request.
Description Type Order No. Price
Flexible flue gas pipe DN 80 Length 12.5 m F8 L1250 15 50 79.00 31 394,70
Length 25.0 m F8 L2500 15 50 79.00 32 787,95
Length 50.0 m F8 L5000 15 50 79.00 33 **1.575,90
Inspection pipe DN 80 for flexible flue pipe F8 RR 15 50 79.00 63 155,55
Chimney head cover for flexpipe
With junction pipe DN 80, including fixing
materials, stainless steel
F8 KAES 15 50 79.01 32 **232,25
Chimney head covering with junction pipe DN 80
Including fixing material, black
F8 KAS 15 50 79.00 67 90,25
Connector DN 80 on chimney head cover EB KAS
For flexible flue gas pipe
F8 AK 15 50 79.00 60 17,10
Coupling
For flexible flue gas pipe DN 80
F8 K 15 50 79.00 61 128,75
Connection sleeve DN 80
For transition from flexible to rigid flue pipe
F8 VM 15 50 79.00 34 61,50
Chimney support DN 80
(Flue gas elbow 87 and support plate with
support rail)
E8 ST 15 50 79.01 11 43,60
Ventilation grid with fly protection
To cover the back-ventilation opening, white
E0 LG 15 50 79.00 91 29,05
F
l
u
e

g
a
s

s
y
s
t
e
m
93
Components for flexible flue gas pipe in shaft DN 80
E7
Description Type Order No. Price
Installation aid for flexible flue gas pipe
DN80 with 20 m rope
F8 MH 15 50 79.00 44 128,15
Lubricant G GM 15 50 79.00 42 4,75
** Delivery period available on request.
Description Type Order No. Price
Flexible flue gas pipe DN 110 Length 15 m F11 L1500 15 50 77.00 54 879,35
Inspection pipe DN 110
For flexible flue gas pipe
F11 RR 15 50 77.00 48 262,15
Chimney head cover for flexpipe
With junction pipe DN 110,
including fixing materials, stainless steel
F11 KAES 15 50 77.00 50 ** 329,40
Chimney head covering with junction pipe DN 110
Including fixing material, black
E11 KAS 15 50 77.00 12 116,10
Connector DN 110 on chimney head
cover E11 KAS
For flexible flue gas pipe
F11 AK 15 50 77.00 55 **48,75
Coupling for flexible flue pipe DN 110 F11 K 15 50 77.00 46 228,60
Connection sleeve DN 110
For transition from flexible to rigid flue gas
pipe
F11 VM 15 50 77.00 47 191,40
Chimney support DN 110
Flue gas elbow 87 and support plate with
support rail
E11 ST 15 50 77.00 10 60,60
Ventilation grid with fly protection
To cover back-ventilation
opening, white
E0 LG 15 50 79.00 91 29,05
Installation aid DN 110
For flexible flue gas pipe with 20 m rope
F11 MH 15 50 77.00 49 194,40
Lubricant G GM 15 50 79.00 42 4,75
Components for flexible flue gas pipe in shaft DN 110
E8
F
l
u
e

g
a
s

s
y
s
t
e
m
Flue gas system accessories: Individual components
93
94
ROTEX A1: Maximum allowable height of the flue gas line in m (when operating in the rated output range)
ROTEX GCU compact and GW: Maximum allowable height of the flue gas line in m (when operating in the rated output range)
Flue gas mass flow in relation to the burner load
Installation version

1
1)
2
1)
3
1)
4
)

5
)
6
)
A1 BO 15-e
A1 BO 20-e
A1 BO 27-e
DN 80
16
21
17
16
17
17
A1 BO 34-e A1 BG 25-e
A1 BG 25-e
DN 80
23
22
22
21
22
22
A1 BG 40-e
A1 BG 40-e
30kW
DN 80
20
21
21
14
11
11
33kW
DN 80
9
21
21
7
7
7
DN 80
8
17
17
14
10
10
DN 110
22
40
25
17

34kW
DN 110
24
30
30
28
23
23
Flue gas system A1, GCU compact, GW rated data
Installation position and piping height:
- The maximum permitted flue gas counterpressure is 200 Pa. The pressure loss in the supply line must not exceed 50 Pa
- Angle of entry of the flue gas pipe into the chimney or installation shaft: approx. 3
- Slope for horizontal parts of the flue gas duct: approx. 3. Counter-gradients are not allowed at any point in the flue gas duct
- If more than 3 bends > 45 are required in the flue gas duct, the maximum permissible height of the flue gas duct will reduce
- By at least 1 m per bend (flue gas calculation may be required)
- If the horizontal connecting piece is extended, the maximum permitted height of the flue gas duct is reduced by exactly that length
- The minimum height of the flue gas conduit must be 2 m in order to avoid malfunction at start or during operation of the burner.*
*) not applicable to GW
1) Shaft cross section for DN 80: 135 x 135 mm, with DN 110: 160 x 160 mm
P Burner loading
m
AG
Flue gas mass flow
A Natural gas E/H
B Natural gas L, LL
C Liquid petroleum gas
D Oil
Installation version

1
4
5
6
GCU compact 315
GCU compact 515
DN 80
10
12
12
12
GCU compact 324
GCU compact 524
DN 80
12
14
14
14
GCU compact 533
DN 80
18
17
17
17
GW 22C / 22T
GW 26C / 26T
GW 37C / 37T
DN 80
10
10
12
22
F
l
u
e

g
a
s

s
y
s
t
e
m
95 95
96
Thermal store and solar storage tank,
ROTEX Sanicube and ROTEX HybridCube
ROTEX Sanicube and ROTEX HybridCube
- Plastlc thermal store wlth stalnless steel corrugated plpe heat exchanger
- Content of storage tank 300 or 500 lltres
- Comblnatlon of hot water storage tank and lnstantaneous through-flow water heater ln fresh water technology
- Optlmum water hyglene
- |ntegrated solar optlon
- Solar heat exchanger for pressurlsed solar comblnatlon
- |nterconnectlon of storage tank batterles ldeal for large volume water demand
Thermal store
T
h
e
r
m
a
l

s
t
o
r
e
97
T
h
e
r
m
a
l

s
t
o
r
e
97
98
Thermal store
T
h
e
r
m
a
l

s
t
o
r
e
Storage tank selection
Thermal store and solar storage tank ROTEX
Sanicube and ROTEX HybridCube
ROTEX Hygienic storage tank HYC
343/19/0-P
HYC
544/19/0-P
HYC
544/32/0-P
SCS
328/14/0-P
SCS
538/16/0-P
SCS
538/16/16-P
Hygienic hot water-generation in
instantaneous through-flow principle
Heat generator combinations
Boiler combination
A1 BO
A1 BG
GW
Existing boiler
Heat pump combination
HPSU Low Temp. to 8 kW
HPSU Low Temp. to 16 kW
HPSU Hi-Temp.
HPSU monobloc
Solar combination
Drain-Back combination
Pressurised solar combination
Solar heating support
Bivalency solution
(combination with additional heat generators or
swimming pool)
If a pressurised solar combination or a bivalency solution is to be combined with a heat pump,
we can use the ROTEX compact heat pump HPSU compact Biv Variant. See page 7, 8.
99
Storage tank selection
Thermal store and solar storage tank ROTEX
Sanicube and ROTEX HybridCube
Thermal store
HYC
343/19/0-DB
HYC
544/19/0-DB
HYC
544/32/0-DB
SCS
328/14/0-DB
SCS
538/0/0-DB
SCS
538/16/0-DB
SCS
538/16/16-DB
SC
538/0/0
SC
538/16/0
SC
538/16/16
99
100
T
h
e
r
m
a
l

s
t
o
r
e
Thermal store
Article Type Order No. Price
Sanicube SCS 328/14/0-P
High-performance 300 litre energy store for
domestic hot water generation.
Dimensions (W x D x H) 595 x 615 x 1646 mm, weight 57kg
SCS 328/14/0-P 16 52 05 1.529,00
Sanicube Solaris SCS 538/16/0-P
High-performance 500 litre stratified storage tank for
hot water generation and heating support.
Dimensions (W x D x H) 790 x 790 x 1,658 mm, weight 93kg
SCS 538/16/0-P 16 52 07 1.889,00
Sanicube Solaris SCS 538/16/16-P
High-performance 500 litre stratified storage tank for hot
water generation and heating support and for bivalency
operation with additional heat generator.
Dimensions (W x D x H) 790 x 790 x 1,658 mm, weight 99 kg
SCS 538/16/16-P 16 52 09 2.169,00
Sanicube Solaris SCS 328/14/0-DB
High-performance 300 litre energy store for domestic hot
water generation.
Dimensions (W x D x H) 595 x 615 x 1646 mm, weight 55 kg
SCS 328/14/0-DB 16 52 04 1.349,00
Sanicube Solaris SCS 538/0/0-DB
High-performance 500 litre stratified storage tank for
hot water generation and heating support.
Dimensions (W x D x H) 790 x 790 x 1,658 mm, weight 82 kg
SCS 538/0/0-DB 16 52 11 1.409,00
Sanicube Solaris SCS 538/16/0-DB
High-performance 500 litre stratified storage tank for
hot water generation and heating support.
Dimensions (W x D x H) 790 x 790 x 1,658 mm, weight 88 kg
SCS 538/16/0-DB 16 52 06 1.689,00
Sanicube Solaris SCS 538/16/16-DB
High-performance 500 litre stratified storage tank for hot
water generation and heating support and for bivalency
operation with additional heat generator.
Dimensions (W x D x H) 790 x 790 x 1,658 mm, weight 94 kg
SCS 538/16/16-DB 16 52 08 1.999,00
HybridCube HYC 343/19/0-P Energy storage for
HPSU Low Temperature up to 8 kW and all HPSU
hitemp
High-performance 300 litre energy store for
domestic hot water generation.
Dimensions (W x D x H) 595 x 615 x 1646 mm, weight 64 kg
HYC 343/19/0-P 14 05 54 1.649,00
HybridCube HYC 544/19/0-P Energy storage for
HPSU Low Temperature up to 8 kW and all HPSU
hitemp
High-performance 500 litre stratified storage tank for
hot water generation and heating support.
Dimensions (W x D x H) 790 x 790 x 1,658 mm, weight 92 kg
HYC 544/19/0-P 14 05 61 1.879,00
Further information about the storage tanks and application see Matrix pages 98, 99 and Technical Documents pages 104 108
Drain-Back system (-DB) Pressurised system (-P)
Thermal store and solar storage tank,
ROTEX Sanicube and ROTEX HybridCube
101
Article Type Order No. Price
HybridCube HYC 544/32/0-P Energy storage for HPSU
HPSU Low Temperature up to 16 kW and all HPSU
hitemp

Low Temperature up to 16 kW and all HPSU
hitemp
High-performance 500 litre stratified storage tank for
hot water generation and heating support.
Dimensions (W x D x H) 790 x 790 x 1,658 mm, weight 98 kg
HYC 544/32/0-P 14 05 63 2.039,00
HybridCube HYC 343/19/0-DB Energy storage for
HPSU Low Temperature up to 8 kW and all HPSU
hitemp

High-performance 300 litre energy store for
hot water generation.
Dimensions (W x D x H) 595 x 615 x 1646 mm, weight 59 kg
HYC 343/19/0-DB 14 05 53 1.469,00
HybridCube HYC 544/19/0-DB Energy storage for
HPSU Low Temperature up to 8 kW and all HPSU
hitemp
High-performance 500 litre stratified storage tank for
hot water generation and heating support.
Dimensions (W x D x H) 790 x 790 x 1,658 mm, weight 87 kg
HYC 544/19/0-DB 14 05 60 1.679,00
HybridCube HYC 544/32/0-DB Energy storage for
HPSU Low Temperature up to 16 kW and all HPSU
hitemp

High-performance 500 litre stratified storage tank for
hot water generation and heating support.
Dimensions (W x D x H) 790 x 790 x 1,658 mm, weight 93 kg
HYC 544/32/0-DB 14 05 62 1.819,00
Sanicube SC 538/0/0
High-performance 500 litre energy storage tank for
hot water generation with optional immersion heater.
Dimensions (W x D x H) 790 x 790 x 1,658 mm, weight 79 kg
SC 538/0/0 16 52 01 1.289,00
Sanicube SC 538/16/0
High-performance 500 litre energy storage tank for
hot water generation by boiler or other heat source.
Dimensions (W x D x H) 790 x 790 x 1,658 mm, weight 85 kg
SC 538/16/0 16 52 02 1.669,00
Sanicube SC 538/16/16
High-performance 500 litre energy storage tank for
hot water generation by boiler or other heat source.
and for bivalency operation with additional heat generator.
Dimensions (W x D x H) 790 x 790 x 1,658 mm, weight 91 kg
SC 538/16/16 16 52 03 1.979,00
US 150
Ready insulated storage tank 150 l total content.
Performance index in accordance with
DIN 4708 T3 1):NL = 2.2
Dimensions (W x D x H) 660 x 1000 x 660 mm,
max. operating temperature 95 C,
max. permissible operating pressure 10 bar,
Empty weight 44 kg
US 150 16 01 52 1.669,00
Further information about the storage tanks and application see Matrix pages 98, 99 and Technical Documents pages 104 108
Drain-Back system (-DB) Pressurised system (-P)
T
h
e
r
m
a
l

s
t
o
r
e
Thermal store
Thermal store and solar storage tank,
ROTEX Sanicube and ROTEX HybridCube
101
102
T
h
e
r
m
a
l

s
t
o
r
e
Thermal store
Thermal store and solar storage tank,
ROTEX Sanicube and ROTEX HybridCube
Thermal store accessories
Electric heating element 240 V
Output 2 kW with integrated temperature regulator
30 78 C and temperature limiter 95 C,
Immersion depth 1420 mm
EHS/500/1 16 51 31 390,40
Electric immersion heater 240/400 V
Output 2 6 kW including temperature controller
and 98 C temperature limiter, immersion depth 1420 mm
EHS/500/5 16 51 35 537,70
Electric immersion heater 240/400 V
Output 2 6 kW including temperature controller and
98 C temperature limiter, immersion depth 1100 mm
For use with Sanicube Solaris
EHS/500/6 16 51 36 505,75
Circulation lance
For energetically-optimised incorporation of the domestic
water circulation in the hot water connection to the
ROTEX storage tank
ZKL 16 51 13 122,10
Thermostatic mixer as scalding protector
Thermal safety device for the domestic
water pipe. Setting range 35 60 C
VTA32 15 60 15 84,00
Screw connection kit 1
For connection of the scald protection VTA32
15 60 16 33,00
Storage tank incorporation A1 (storage tank return
connection and electric immersion heater connection)
Kit for connecting a ROTEX A1 condensing boiler to the
HPSU compact or a ROTEX storage tank (compatible with
all models from 2013).
Consisting of: piping, fittings, storage tank incorporation.
Unpressurised mode
SAA1 16 01 25 144,00
Storage tank incorporation heat exchanger Variant 2
(storage tank return connection and electric immersion
heater connection)
Kit for connection of a wood-burning, pellet, oil or
gas boiler to the HPSU compact or a ROTEX storage
tank(compatible with all mdels from 2013) as an
alternative to an electric immersion heater. Consists of:
piping, fittings, storage tank incorporation and circulation
pump. For the connection of a boiler to the unpressurised
area, you will need an additional plate heat exchanger
(e.g. ROTEX RPWT1 Order No. 16 20 31). This variant can
only be realised with controllable heat generators
SAK 16 01 27 263,00
ROTEX Solaris plate heat exchanger (6 kW)
For connecting the ROTEX PRESSURE STATION to an
unpressurised storage tank. For pressurised solar systems
with up to 5 solar panels
RPWT1 16 20 31 379,00
Connection elbow SCS/HYC
The optional connection elbow enables easy filling of the
storage tank via the filling and drain connection on the
storage tank (1" female thread connection)
AW BAS 16 52 10 35,00
Convection brake
To prevent circulation under gravity
in Sanicube water circuits with Drain-Back, 2 in number
16 50 70 11,55
103
T
h
e
r
m
a
l

s
t
o
r
e
Thermal store
103
104
T
h
e
r
m
a
l

s
t
o
r
e
Sanicube Solaris (storage tank for boiler with solar)
Pressurised solar
300 litres 500 litres
SCS 328 / 14 / 0-P SCS 538 / 16 / 0-P SCS 538 / 16 / 16-P
16 52 05 16 52 07 16 52 09
Basic data
Total storage capacity Litres 300 500 500
Empty weight kg 57 93 99
Total filled weight kg 357 593 599
Dimensions (W x D x H) mm 595 x 615 x 1646 790 x 790 x 1658 790 x 790 x 1658
Tilt dimension cm 163 167 167
Max. permissible storage water temperature C 85 85 85
Readiness heat consumption at 60 C storage tank temp. kWh / 24h 1,3 1,4 1,4
Drinking water heating
Drinking water capacity Litres 19 24,5 24,5
Maximum operating pressure bar 6 6 6
Drinking water heat exchanger material stainless steel stainless steel stainless steel
Drinking water heat exchanger surface m 3,9 5 5
Storage tank charging heat exchanger (stainless steel)
Water capacity heat exchanger Litres 9,4 10,5 10,5
Surface of charging heat exchanger m 1,9 2,1 2,1
Storage tank charging heat exchanger 2 (stainless steel)
Water capacity heat exchanger Litres 11,3
Surface of charging heat exchanger m
2
2,3
Pressurised solar heat exchanger (stainless steel)
Water capacity heat exchanger Litres 4,2 12,5 12,5
Surface of charging heat exchanger m
2
0,8 1,7 1,7
Solar heating support (stainless steel)
Water capacity heat exchanger Litres 3,2 3,2
Surface of charging heat exchanger m
2
0,4 0,4
Thermal output data Sanicube
Output characteristic value N
L
according to DIN 4708
1)
2,2 2,3 2,5
Continuous rating Q
D
according to DIN 4708 kWh / 24 h 27 35 45
Max. draw-off rate for a period of 10 min. at 35 kW with
(T
KW
= 10 C / T
WW
= 40 C / T
SP
= 60 C)
l / mi
21 22 24
Hot water volume without reheating at 15 l / min.
Draw-off rate (T
KW
= 10 C / T
WW
= 40C / T
SP
= 60 C)
Litres
200 230 230
(405)*
Hot water volume with heating up at a power rating of
20 kW and 15 l / min draw-off rate
(T
KW
= 10 C / T
WW
= 40 C / T
SP
= 60 C)
Litres 400 500
500
(858)*
Short-term water quantity in 10min. Litres 210 220 240
Thermal output data HybridCube
Hot water volume without reheating at
8 l / min / 12 l / min draw-off rate
(T
KW
= 10 C / T
WW
= 40 C / T
SP
= 50 C)
Litres

Hot water volume without reheating at 8 l / min / 12 l / min draw-
off rate (T
KW
= 10 C / T
WW
= 40 C / T
SP
= 60 C)
Litres

Hot water volume without reheating at 8 l / min / 12 l / min draw-
off rate (T
KW
= 10 C / T
WW
= 40 C / T
SP
= 65 C)
Litres

Reheating time draw-off volume 140 l -> 5820 Wh
(bath draw-off )
min.

Reheating time draw-off volume 90 l -> 3660 Wh
(shower draw-off )
min.

Pipe connections
Cold and hot water Inch 1 male thread 1 male thread 1 male thread
Heating inflow and return flow Inch 1 male thread 1 male thread 1 male thread
Drain-back connection Inch
Connection pressurised solar Inch 3 / 4 female thread 3 / 4 female thread 3 / 4 female thread
Technical data
Thermal store and solar storage tank
ROTEX Sanicube Solaris
Thermal store
105
Sanicube Solaris (storage tank for boiler with solar)
Drain-Back
300 litres 500 litres
SCS 328/14/0-DB SCS 538/0/0-DB SCS 538 / 16 / 0-DB SCS 538/16/16-DB
16 52 04 16 52 11 16 52 06 16 52 08
300 500 500 500
55 82 88 94
355 582 588 594
595 x 615 x 1646 790 x 790 x 1658 790 x 790 x 1658 790 x 790 x 1658
170 167 167 167
85 85 85 85
1,3 1,4 1,4 1,4
19 24,5 24,5 24,5
6 6 6 6
stainless steel stainless steel stainless steel stainless steel
3,9 5 5 5
9,4 10,5 10,5
1,9 2,1 2,1
11,3
2,3


3,2 3,2 3,2
0,4 0,4 0,4
2,2 2,3 2,5
27 35 45
21 22 24
200 230 230
(405)*
400 500 500
(858)*
210 220 240





1 male thread 1 male thread 1 male thread 1 male thread
1 male thread 1 male thread 1 male thread
1 male thread 1 female thread 1" female thread 1 male thread

* With storage tank charging heat
exchanger completely filled
1)
With reloading of 35 kW,
80 C feed flow temperature,
65 C storage tank temp.,
45 C Hot water temperature,
45 C Hot water temperature,
and 10 cold water temperature
Reheating time = The time needed
to reheat the thermal store to a
temperature of 50C after a certain
quantity of DHW has been discharged.
Thermal store
105
106
T
h
e
r
m
a
l

s
t
o
r
e
Thermal store
HybridCube (storage tank fot heat pump)
Pressurised solar
300 litres 500 litres
HYC 343/19/0-P HYC 544/19/0-P HYC 544/32/0-P
14 05 54 14 05 61 14 05 63
Basic data
Total storage capacity Litres 300 500 500
Empty weight kg 64 92 98
Total filled weight kg 364 592 598
Dimensions (W x D x H) mm 595 x 615 x 1646 790 x 790 x 1658 790 x 790 x 1658
Tilt dimension cm 170 167 167
Max. permissible storage water temperature C 85 85 85
Readiness heat consumption at 60 C storage tank temp. kWh / 24h 1,3 1,4 1,4
Drinking water heating
Drinking water capacity Litres 27,9 29 29
Maximum operating pressure bar 6 6 6
Drinking water heat exchanger material stainless steel stainless steel stainless steel
Drinking water heat exchanger surface m 5,8 5,8 5,8
Storage tank charging heat exchanger (stainless steel)
Water capacity heat exchanger Litres 13,2 9,9 18,5
Surface of charging heat exchanger m 2,7 2 3,8
Storage tank charging heat exchanger 2 (stainless steel)
Water capacity heat exchanger Litres
Surface of charging heat exchanger m
2

Pressurised solar heat exchanger (stainless steel)
Water capacity heat exchanger Litres 4,2 12,5 12,5
Surface of charging heat exchanger m
2
0,8 1,7 1,7
Solar heating support (stainless steel)
Water capacity heat exchanger Litres 2,3 2,3
Surface of charging heat exchanger m
2
0,5 0,5
Thermal output data Sanicube
Output characteristic value N
L
according to DIN 4708
1)

Continuous rating Q
D
according to DIN 4708 kWh / 24 h
Max. draw-off rate for a period of 10 min. at 35 kW with
(T
KW
= 10 C / T
WW
= 40 C / T
SP
= 60 C)
l / mi
Hot water volume without reheating at 15 l / min.
Draw-off rate (T
KW
= 10 C / T
WW
= 40C / T
SP
= 60 C)
Litres
Hot water volume with heating up at a power rating of
20 kW and 15 l / min draw-off rate
(T
KW
= 10 C / T
WW
= 40 C / T
SP
= 60 C)
Litres

Short-term water quantity in 10min. Litres
Thermal output data HybridCube
Hot water volume without reheating at
8 l / min / 12 l / min draw-off rate
(T
KW
= 10 C / T
WW
= 40 C / T
SP
= 50 C)
Litres 184 / 153 324 / 282
(288 / 240)**
324 / 282
(288 / 240)**
Hot water volume without reheating at 8 l / min / 12 l / min draw-
off rate (T
KW
= 10 C / T
WW
= 40 C / T
SP
= 60 C)
Litres 282 / 252 492 / 444 492 / 444
Hot water volume without reheating at 8 l / min / 12 l / min draw-
off rate (T
KW
= 10 C / T
WW
= 40 C / T
SP
= 65 C)
Litres 352 / 321 560 / 516 560 / 516
Reheating time draw-off volume 140 l -> 5820 Wh
(bath draw-off )
min. 45
(HPSU 008)
45
(HPSU 008)
25
(HPSU 016)
Reheating time draw-off volume 90 l -> 3660 Wh
(shower draw-off )
min. 30
(HPSU 008)
30
(HPSU 008)
17
(HPSU 016)
Pipe connections
Cold and hot water Inch 1 male thread 1 male thread 1 male thread
Heating inflow and return flow Inch 1" female thread /
1"male thread
1" female thread /
1"male thread
1" female thread /
1"male thread
Drain-back connection Inch
Connection pressurised solar Inch 3 / 4 female thread 3 / 4 female thread 3 / 4 female thread
Technical data
Thermal store and solar storage tank
ROTEX HybridCube
107
HybridCube (storage tank for heat pump)
Drain-Back
300 litres 500 litres
HYC 343 / 19 / 0-DB HYC 544/19/0-DB HYC 544/32/0-DB
14 05 53 14 05 60 14 05 62
300 500 500
59 87 93
359 587 593
595 x 615 x 1646 790 x 790 x 1658 790 x 790 x 1658
163 167 167
85 85 85
1,3 1,4 1,4
27,9 27,9 27,9
6 6 6
stainless steel stainless steel stainless steel
5,8 6 6
13,2 9,9 18,5
2,7 2 3,8




2,3 2,3
0,5 0,5






184 / 153 364 / 318
(328 / 276)**
364 / 318
(328 / 276)**
282 / 252 540 / 494 540 / 494
352 / 321 612 / 564 612 / 564
45
(HPSU 008)
45
(HPSU 008)
25
(HPSU 016)
30
(HPSU 008)
30
(HPSU 008)
17
(HPSU 016)
1 male thread 1 male thread 1 male thread
1" female thread /
1"male thread
1" female thread /
1"male thread
1" female thread /
1"male thread
1" female thread 1" female thread 1" female thread

T
h
e
r
m
a
l

s
t
o
r
e
Thermal store

** Storage tank only with heat pump
charging without immersion heater
1)
With reloading of 35 kW,
80 C feed flow temperature,
65 C storage tank temp.,
45 C Hot water temperature,
45 C Hot water temperature,
and 10 cold water temperature
Reheating time = The time needed
to reheat the thermal store to a
temperature of 50C after a certain
quantity of DHW has been discharged.
107
108
Sanicube Solaris (storage tank for boiler without solar)
500 litres
SC 538/0/0 SC 538/16/0 SC 538/16/16
16 52 01 16 52 02 16 52 03
Basic data
Total storage capacity Litres 500 500 500
Empty weight kg 79 85 91
Total filled weight kg 579 585 591
Dimensions (W x D x H) mm 790 x 790 x 1658 790 x 790 x 1658 790 x 790 x 1658
Tilt dimension cm 167 167 167
Max. permissible storage water temperature C 85 85 85
Readiness heat consumption at 60 C storage tank temp. kWh / 24h 1,4 1,4 1,4
Drinking water heating
Drinking water capacity Litres 24,5 24,5 24,5
Maximum operating pressure bar 6 6 6
Drinking water heat exchanger material stainless steel stainless steel stainless steel
Drinking water heat exchanger surface m 5 5 5
Storage tank charging heat exchanger (stainless steel)
Water capacity heat exchanger Litres 18,5 13,2 9,9
Surface of charging heat exchanger m 3,8 2,7 2
Storage tank charging heat exchanger 2 (stainless steel)
Water capacity heat exchanger Litres 10,6 10,6
Surface of charging heat exchanger m
2
2,1 2,1
Pressurised solar heat exchanger (stainless steel)
Water capacity heat exchanger Litres 11,3
Surface of charging heat exchanger m
2
2,3
Solar heating support (stainless steel)
Water capacity heat exchanger Litres
Surface of charging heat exchanger m
2

Thermal output data Sanicube
Output characteristic value N
L
according to DIN 4708
1)
4,1 4,4
Continuous rating Q
D
according to DIN 4708 kWh / 24 h 35 50
Max. draw-off rate for a period of 10 min. at 35 kW with
(T
KW
= 10 C / T
WW
= 40 C / T
SP
= 60 C)
l / mi 30 31
Hot water volume without reheating at 15 l / min.
Draw-off rate (T
KW
= 10 C / T
WW
= 40C / T
SP
= 60 C)
Litres 420 420
Hot water volume with heating up at a power rating of
20 kW and 15 l / min draw-off rate
(T
KW
= 10 C / T
WW
= 40 C / T
SP
= 60 C)
Litres

970 970
Short-term water quantity in 10min. Litres 300 310
Thermal output data HybridCube
Hot water volume without reheating at
8 l / min / 12 l / min draw-off rate
(T
KW
= 10 C / T
WW
= 40 C / T
SP
= 50 C)
Litres
Hot water volume without reheating at 8 l / min / 12 l / min draw-
off rate (T
KW
= 10 C / T
WW
= 40 C / T
SP
= 60 C)
Litres
Hot water volume without reheating at 8 l / min / 12 l / min draw-
off rate (T
KW
= 10 C / T
WW
= 40 C / T
SP
= 65 C)
Litres
Reheating time draw-off volume 140 l -> 5820 Wh
(bath draw-off )
min.
Reheating time draw-off volume 90 l -> 3660 Wh
(shower draw-off )
min.
Pipe connections
Cold and hot water Inch 1 male thread 1 male thread 1 male thread
Heating inflow and return flow Inch 1" female thread /
1"male thread
1" female thread /
1"male thread
1" female thread /
1"male thread
Drain-back connection Inch
Connection pressurised solar Inch
1)
With reloading of 35 kW, 80 C feed flow temperature, 65 C storage tank temp., 45 C Hot water temperature, 45 C Hot water temperature,
and 10 cold water temperature
time = The time needed to reheat the thermal store to a temperature of 50C after a certain quantity of DHW has been discharged.
Technical data
Thermal store tank
ROTEX Sanicube
Thermal store
109
Thermal store
109
110
Solar system for pressurised use and Drain-Back,
ROTEX Solaris
Solar heating system
S
o
l
a
r

h
e
a
t
i
n
g

s
y
s
t
e
m
ROTEX Solaris
- Plexlble solar system for pressurlsed solar system
for pressurised solar applications and Drain-Back
- Hot water generatlon and heatlng support
- Hlghly effectlve stratlfled storage tank
- Optlmum water hyglene by fresh water technology
- Hlgh-efflclency flat solar panels ln 3 slzes
- On-roof, ln-roof and flat-roof lnstallatlon `
* Please note the installation instructions in the installation manuals.
111
Solar system Overview V21P
S
o
l
a
r

h
e
a
t
i
n
g

s
y
s
t
e
m
Number of solar panels
Type of installation
Article Type
Ordering
No.
2
On-roof
Quantity
2
In-roof
Quantity
3
On-roof
Quantity
3
In-roof
Quantity
4
On-roof
Quantity
4
In-roof
Quantity
5
On-roof
Quantity
5
In-roof
Quantity
Solaris flat collector Solaris V21P 16 20 12 2 2 3 3 4 4 5 5
Solar panel connection FIX-VBP 16 20 16 1 1 2 2 3 3 4 4
Installation rail for individual solar
panel
FIX MP 100 16 20 66 2 2 3 3 4 4 5 5
On-roof installation kit for one
solar panel
DB)
(4 roof hooks per kit)
FIX-ADP 16 20 36 2 0 3 0 4 0 5 0
Standard roof hook pressurised
solar
P)
(1 roof hook per kit)
FIX-ADD 16 20 69 6 0 10 0 12 0 14 0
In-roof installation package,
Basic storage for two solar panel
IB V21P 16 20 17 0 1 0 1 0 1 0 1
In-roof installation package,
Additional storage for central solar
panel
IE V21P 16 20 18 0 0 0 1 0 2 0 3
Sum gross
1)
Drain-Back system in
Sum gross
1)
Pressurised system in
1452,45
1386,45
1773,45
1773,45
2206,90
2129,90
2657,90
2657,90
2961,35
2829,35
3542,35
3542,35
3715,80
3528,80
4426,80
4426,80
Type of installation
Type
Order
No.
On-roof
Quantity
In-roof
Quantity
Sanicube Solaris
SCS 538/16/0-DB
SCS
538/16/0-DB
16 52 06 1 1
Control and pump unit RPS 3 16 41 25 1 1
Support troughs for Solaris
Connecting pipe
TS 16 42 45 1 1
Solaris connection pipe CON 15 16 47 32 1 1
Roof penetration pack
Solaris on-roof
RCAP
RCRP
16 20 33
anthracite
16 20 34
red
1 0
Installation accessories,
Solaris in-roof
RCIP 16 20 37 0 1
Sum gross
1)
in 2.845,00 2.745,00
List of materials Solaris Drain-Back standard systems
Number of solar panels
Article Type
Order
No.
up to 2
Quantity
up to 3
Quantity
4 to 5
Quantity
Sanicube Solaris
SCS 538/16/0-P
SCS 538/16/0-P 16 52 07 1 1 1
Solaris pressurised solar regulator DSR1 16 20 43 1 1 1
ROTEX Solaris pressure station RDS1 16 20 30 1 1 1
Solaris pressurised solar line
DN16 15m
CON 15P16 16 20 73 1 1 0
Solaris pressurised solar connection kit
DN16
CON CP16 16 20 75 1 1 0
Solaris pressurised solar line
DN20 15m
CON 15P20 16 20 74 0 0 1
Solaris pressurised solar connection kit
DN20
CON CP20 16 20 76 0 0 1
Diaphragm expansion vessel
Solaris 12l
MAG S12 16 20 70 1 0 0
Diaphragm expansion vessel
Solaris 25l **
MAG S 25 16 20 50 0 1 0
Diaphragm expansion vessel
Solaris 35l **
MAG S 35 16 20 51 0 0 1
Solaris installation material
Pressurised system
2)
RCP 16 20 39 1 1 1
Sum gross
1)
in 3.233,00 3.253,00 3.433,00
Material listingSolaris pressurised installations
2)
Material list for standard Solaris systems for hot water preparation and heating support V21P
Drain-Back system
Pressurised system
DB) Required only for Drain-Back
installations.
P) Only required for pressurised
installations.
* Optional accessories not included in
price.
** Simply a standard recommendation,
after detailed MAG layout, in
accordance with the individual
framework conditions, other MAG
types may be required.
1) Non-binding price details in
accordance with ROTEX Price List
04/2013
2) The roof penetration for on-roof and
flat roof installation is to be provided
by the customer. The solar fluid must
be ordered separately.
Number of solar panels 2 3 4 5
Connecting line 15 m DN 16 DN 16 DN 20 DN 20
Nominal system volume (l) 20,2 21,5 22,8 24,1
Solar panel
V21P
Nominal volume, complete system
111
112
S
o
l
a
r

h
e
a
t
i
n
g

s
y
s
t
e
m
Solar system Overview V21P
Material list for standard Solaris systems for hot water preparation and heating support V26P
Number of solar panels
Type of installation
Article Type
Order
No.
2
On-roof
Quantity
2
In-roof
Quantity
2
Flat roof
Quantity
3
On-roof
Quantity
3
In-roof
Quantity
3
Flat roof
Quantity
4
On-roof
Quantity
4
In-roof
Quantity
4
Flat roof
Quantity
5
On-roof
Quantity
5
In-roof
Quantity
5
Flat roof
Quantity
Solaris flat collector Solaris
V26P
16 20 10 2 2 2 3 3 3 4 4 4 5 5 5
Solar panel connection FIX-VBP 16 20 16 1 1 1 2 2 2 3 3 3 4 4 4
Mounting rail
single collector
FIX
MP 130
16 20 67 2 2 2 3 3 3 4 4 4 5 5 5
On-roof installation pack
for one solar panel
DB)
(4 roof hook per kit)
FIX-ADP 16 20 36 2 0 0 3 0 0 4 0 0 5 0 0
Standard roof hook pres-
surised solar
P)

(1 roof hook per kit)
FIX
ADD
16 20 69 6 0 0 10 0 0 12 0 0 14 0 0
In-roof installation kit,
basic flashing for two
solar panels
IB
V26P
16 20 19 0 1 0 0 1 0 0 1 0 0 1 0
In-roof installation pack,
additional flashing for
central solar panel
IE
V26P
16 20 20 0 0 0 0 1 0 0 2 0 0 3 0
Flat-roof frame, basic
pack for two solar panels
FB
V26P
16 20 58 0 0 1 0 0 1 0 0 1 0 0 1
Flat-roof frame,
expansion pack
additional solar panel
FE
V26P
16 20 59 0 0 0 0 0 1 0 0 2 0 0 3
Sum gross
1)
Drain-Back system in
Sum gross
1)
Pressurised system in
1.676,45
1.610,45
2.017,45
2.017,45
1.917,45
1.917,45
2.542,90
2.465,90
3.023,90
3.023,90
2.873,90
2.873,90
3.409,35
3.277,35
4.030,35
4.030,35
3.830,35
3.830,35
4.275,80
4.088,80
5.036,80
5.036,80
4.786,80
4.786,80
Solar panel
V26P
Number of solar panels
Installation type / item Type
Order No. On-roof
Quantity
In-roof
Quantity
Flat roof
Quantity
Sanicube Solaris SCS 538/16/0-DB SCS 538/16/0-DB 16 52 06 1 1 1
Control and pump unit RPS 3 16 41 25 1 1 1
Additional support troughs for Solaris connection line TS 16 42 45 1 1 1
Solaris connection pipe CON 15 16 47 32 1 1 1
Roof penetration pack Solaris on-roof RCAP
RCRP
16 20 33 Anthracite
16 20 34 Red
1 0 0
Installation accessories, Solaris in-roof RCIP 16 20 37 0 1 0
Roof penetration pack flat roof RCFP 16 20 38 0 0 1
Sum gross
1)
in 2.845,00 2.745,00 2.845,00
List of materials Solaris Drain-Back standard systems
Number of solar panels
Article Type
Order No. up to 2
Quantity
up to 3
Quantity
4 to 5
Quantity
Sanicube Solaris SCS 538/16/0-P SCS 538/16/0-P 16 52 07 1 1 1
Solaris pressurised solar regulator DSR1 16 20 43 1 1 1
ROTEX Solaris pressure station RDS1 16 20 30 1 1 1
Solaris pressurised solar line DN16 15m CON 15P16 16 20 73 1 1 0
Solaris pressurrised solar connection kit
DN16
CON CP16 16 20 75 1 1 0
Solaris pressurised solar line DN20 15m CON 15P20 16 20 74 0 0 1
Solaris pressurised solar connection kit
DN20
CON CP20 16 20 76 0 0 1
Diaphragm expansion vessel Solaris 12l MAG S12 16 20 70 1 0 0
Diaphragm expansion vessel Solaris 25l * MAG S 25 16 20 50 0 1 0
Diaphragm expansion vessel Solaris 35l ** MAG S 35 16 20 51 0 0 1
Installation material Solaris pressurised
system
2)
RCP 16 20 39 1 1 1
Sum gross
1)
in 3.233,00 3.253,00 3.433,00
Material listingSolaris pressurised installations
2)
Number of solar
panels
2 3 4 5
Connecting
line 15 m
DN
16
DN
16
DN
20
DN
20
Nominal volume
Entire system (l)
21 22,7 24,4 26,1
Nominal volume, complete system
Observe footmotes on
page113!
113
S
o
l
a
r

h
e
a
t
i
n
g

s
y
s
t
e
m
Solar system Overview V26P
Material list for standard Solaris systems for hot water generation and heating support H26P
Type of installation
Article Type
Order No. On-roof
Quantity
Flat roof
Quantity
Sanicube Solaris SCS 538/16/0-DB SCS
538/16/0-DB
16 52 06 1 1
Control and pump unit RPS 3 16 41 25 1 1
Solaris FlowGuard FLG 16 41 02 (1)* (1)*
Support trough for Solaris connection line TS 16 42 45 1 1
Solaris connection pipe CON 15 16 47 32 1 1
Roof penetration pack
Solaris on-roof
RCAP

RCRP
16 20 33
Anthracite
16 20 34
Red
1 1
Roof penetration pack Solaris flat roof RCFP 16 20 38 0 1
Sum gross
1)
in 2.845,00 2.946,00
List of materials Solaris Drain-Back standard systems
Number of solar panels
Article Type
Order No. up to 3
Quantity
4 to 5
Quantity
Sanicube Solaris SCS 538/16/0-P SCS
538/16/0-P
16 52 07 1 1
Solaris pressurised solar regulator DSR1 16 20 43 1 1
ROTEX Solaris pressure station RDS1 16 20 30 1 1
Solaris pressurised solar line DN16 15m CON 15P16 16 20 73 1 0
Solaris pressurrised solar connection kit DN16 CON CP16 16 20 75 1 0
Solaris pressurised solar line DN20 15m CON 15P20 16 20 74 0 1
Solaris pressurised solar connection kit DN20 CON CP20 16 20 76 0 1
Diaphragm expansion vessel Solaris 12l MAG S12 16 20 70 0 0
Diaphragm expansion vessel Solaris 25l ** MAG S 25 16 20 50 1 0
Diaphragm expansion vessel Solaris 35l ** MAG S 35 16 20 51 0 1
Installation material Solaris pressurised system
2)
RCP 16 20 39 1 1
Sum gross
1)
in 3.253,00 3.433,00
Material listingSolaris pressurised installations
2)
Number of solar
panels
2 3 4 5
Connecting
line 15 m
DN
16
DN
16
DN
20
DN
20
Nominal volume
System (I)
21,6 23,9 26 28,1
Solar panel
H26 P
Number of solar panels
Type of installation
Article Type
Order
No.
1
On-roof
Quantity
1
Flat roof
Quantity
2
On-roof
Quantity
2
Flat roof
Quantity
3
On-roof
Quantity
3
Flat roof
Quantity
4
On-roof
Quantity
4
Flat roof
Quantity
5
On-roof
Quantity
5
Flat roof
Quantity
Solaris flat collector Solaris
H26P
16 20 11 1 1 2 2 3 3 4 4 5 5
Solar panel connection FIX-VBP 16 20 16 0 0 1 1 2 2 3 3 4 4
Installation rail guide for
individual solar panel
FIX MP
200
16 20 68 1 1 2 2 3 3 4 4 5 5
On-roof installation pack
for one solar panel
DB)
(4 roof hook per kit)
FIX-ADP 16 20 36 1 0 2 0 3 0 4 0 5 0
Standard roof hook pres-
surised solar
P)

(1 roof hook per kit)
FIX-
ADD
16 20 69 4 0 6 0 10 0 12 0 14 0
Flat roof support frame
basic kit for one solar panel
FB
H26P
16 20 60 0 1 0 1 0 1 0 1 0 1
Flat roof trestle
Extension pack for one
additional solar panel
FE
H26P
16 20 61 0 0 0 1 0 2 0 3 0 4
Sum gross
1)
Drain-Back system in
Sum gross
1)
Pressurised system in
850,00
839,00
1.010,00
1.010,00
1.756,45
1.690,45
1.996,45
1.996,45
2.662,90
2.585,90
2.982,90
2.982,90
3.569,35
3.437,35
3.969,35
3.969,35
4.475,80
4.288,80
4.955,80
4.955,80
Drain-Back system
Pressurised system
DB) Required only for Drain-Back
installations.
P) Only required for pressurised
installations.
* Optional accessories not included in
price.
** Simply a standard recommendation,
after detailed MAG layout, in
accordance with the individual
framework conditions, other MAG
types may be required.
1) Non-binding price details in
accordance with ROTEX Price List
04/2012
2) The roof penetration for on-roof and
flat roof installation is to be provided
by the customer. The solar fluid must
be ordered separately.
Nominal volume, complete system
113
114
S
o
l
a
r

h
e
a
t
i
n
g

s
y
s
t
e
m
Solar heating system
Total number of storage tanks
Article Type Order No.
2
Quantity
3
Quantity
Sanicube Solaris
SCS 538/16/0-DB
SCS 538/16/0-DB 16 52 06 2 3
Solaris storage tank
extension kit
CON SX 16 01 20 1 1
Solaris storage tank
extension kit 2
CON SXE 16 01 21 0 1
Sum gross
1)
in 3.567,00 5.435,00
1)
non-binding price details as per ROTEX Price List 04 / 2013.
List of materials for solar components that connect several storage tanks
115
S
o
l
a
r

h
e
a
t
i
n
g

s
y
s
t
e
m
Solar heating system
Solaris high-efficiency flat solar panel
Stable watertight solar panel frame made of black anodised aluminium, highly selective coating, special safety glass, low-reflexion,
efficient heat insulation of the solar panel floor with mineral wool. Minimum collector yield over 525 kWh / m
2
per year (location
Wrzburg). Suitable for drain-back and pressurised systems.
Solar system for pressurised use and Drain-Back,
ROTEX Solaris
Article Type Order No. Price
Solaris high-efficiency flat solar panel V21P
(2000 x 1006 x 85 mm), opening area 1.79 m,
Weight 35 kg, water content 1.3 l. Max. 6 bar
V21P 16 20 12 560,00
Solaris high-efficiency flat solar panel V26P
(2000 x 1300 x 85 mm), opening area 2.35 m,
Weight 42 kg, water content 1.7 l. Max. 6 bar
V26P 16 20 10 662,00
Solaris high-efficiency flat solar panel H26P
(1300 x 2000 x 85 mm), opening area 2.35 m,
Weight 42 kg, water content 2.1 l. Max. 6 bar
H26P 16 20 11 682,00
Solaris solar panel connection
Installation profile connector, expansion joints
and double clamping blocks
FIX-VBP 16 20 16 56,45
Installation profile rail for V21P
Consisting of installation profile rails and
Solar panel securing clip
FIX MP 100 16 20 66 39,00
Installation profile rail for V26P
Consisting of installation profile rails and
Solar panel securing clip
FIX MP 130 16 20 67 49,00
Installation profile rail for H26P
Consisting of installation profile rails and
Solar panel securing clip
FIX MP 200 16 20 68 69,00
Support trough for Solaris connection line
Support troughs (5 in number, length, in each case,
1.3m) for support of the Solaris plastic connection lines
in Drain-Back.
TS 16 42 45 19,00
On-roof installation pack slate
4 roof ties for flat roofing, e.g. slate,
for one solar panel
FIX ADS 16 47 23 66,25
On-roof installation kit MULTI for one solar panel
4 double height-adjustable roof ties for drainback
system including fixing materials for one solar panel
FIX-ADP 16 20 36 99,00
Standard roof ties for pressurised solar
1 roof tie incl. attachment material
FIX-ADD 16 20 69 22,00
Roof holder for corrugated covering
4 holders including fixing material for one solar panel
FIX-WD 16 47 03 63,70
Roof holder for welted sheet metal covering
4 holders including fixing material for one solar panel
FIX-BD 16 47 04 77,25
Drain-Back system Pressurised system
115
116
S
o
l
a
r

h
e
a
t
i
n
g

s
y
s
t
e
m
Solar heating system
Article Type Order No. Price
Basic in-roof mounting pack V21P
Basic flashing for two solar panels,
Covering sheets complete with installation material.
Minimum roof gradient 15
IB V21P 16 20 17 519,00
Expansion in-roof mounting pack V21P
Additional flashing for another solar panel,
Covering sheets complete with installation material.
Minimum roof gradient 15
IE V21P 16 20 18 229,00
Basic in-roof mounting pack V26P
Basic flashing for two solar panels,
Covering sheets complete with installation material.
Minimum roof gradient 15
IB V26P 16 20 19 539,00
Expansion in-roof mounting pack V26P
Additional flashing for another solar panel,
Covering sheets complete with installation material.
Minimum roof gradient 15
IE V26P 16 20 20 239,00
In-roof covering slate supplementary pack
30 layer pieces for flat coverings, e.g. slate
(per basic in-roof pack you will need
one supplementary pack.)
FIX-IES 16 46 16 162,70
Basic pack flat-roof frame for mounting of
two V26P solar panels on flat roofs
Pre-assembled system for simple and rapid installation,
stepwise adjustable erection angle
(30 to 60). Suitable for wind load zone WLZ 2
(only to a limited extent for WLZ 3)
FB V26P 16 20 58 439,00
Extension pack flat-roof frame for
one additional V26P solar panel
Extension for FB V26P
FE V26P 16 20 59 189,00
Basic pack flat-roof frame for mounting of
one H26P collector on flat roofs
Pre-assembled system for simple and rapid installation,
stepwise adjustable erection angle (30 to 60).
Suitable for wind load zone WLZ 2
(only to a limited extent for WLZ 3)
FB H26P 16 20 60 259,00
Extension pack flat-roof frame for one
additional H26P solar panel
Extension for FB H26P
FE H26P 16 20 61 179,00
Detaching tool FIX LP 16 20 29 11,00
Solar system for pressurised use and Drain-Back,
ROTEX Solaris
117
S
o
l
a
r

h
e
a
t
i
n
g

s
y
s
t
e
m
Solar heating system
Solar system for pressure use,
ROTEX Solaris
Article Type Order No. Price
Solaris pressurised solar regulator
Solar differential temperature regulator for the ROTEX
Solaris pressurised system. Regulator with graphic display
for representation of hydraulic schematics and yield
balances, for example.
Including return flow and storage tank temperature sensor
and housing for wall mounting.
DSR1 16 20 43 159,00
ROTEX pressure station
Consists of: Pipe connection 22 mm including pipe
compression fittings and support sleeves (5x),
Flow measurement unit with 2 x KFE cock,
integrated air separator, ball-cocks with integrated back-
flow prevention, Grundfos Solar 25-65 pump, Safety group
with pressure gauge, including insulation and installation
accessories.
RDS 1 16 20 30 339,00
Solaris pressurised solar line DN 16
15 m thermally-insulated stainless steel corrugated pipe
line for solar pressurised systems with inserted sensor line
nominal size DN 16. For systems up to 3 solar panels and a
line length of up to 25 m.
Without connection fittings.
CON 15P16 16 20 73 459,00
Solaris pressurised solar connection kit DN 16
All necessary fittings for connecting the pressurised solar
line DN 16. Required together with CON 15P16.
CON CP16 16 20 75 69,00
Solaris pressurised solar line connector DN 16
Fittings for connecting two pressurised solar lines
DN 16.
CON XP16 16 20 71 39,00
Solaris pressurised solar line DN 20
15 m thermally-insulated stainless steel corrugated pipe
line for solar pressurised systems with inserted sensor line
nominal size DN 20. For systems up to 5 solar panels and a
line length of up to 25 m. Without connection fittings
CON 15P20 16 20 74 579,00
Solaris pressurised solar connection kit DN 20
All necessary fittings for connecting the pressurised solar line
DN 20. Always required together with CON 15P20.
CON CP20 16 20 76 99,00
Solaris pressurised solar line connector DN 20
Fittings for connecting two pressurised solar lines
DN 20
CON XP20 16 20 72 27,00
Installation material Solaris pressurised system
Connection fittings for pressurised systems and solar panel
installation material, consisting of installation material for
solar panel and connection pipe, 2 m UV-proof thermal
insulation for the outer area, connection fittings with
detaching tools and panel temperature sensor. The roof
penetration must be provided by the customer
RCP 16 20 39 189,00
Solar panel series connector for Solaris pressure system
Connection kit for connecting two rows of solar panels
on top of each other. Consisting of solar panel installation
material, equipotential bonding terminals, end caps,
pressure connection elbows and 1 m thermally-insulated
connectiong pipe
CONLCP 16 20 45 149,00
Diaphragm expansion tank 12l with
connection group
For ROTEX Solaris pressurised installations up to
max. 2 x V21P / V26P - solar panels
MAG S12 16 20 70 129,00
117
118
S
o
l
a
r

h
e
a
t
i
n
g

s
y
s
t
e
m
Solar heating system
Solar system for pressure use,
ROTEX Solaris
Article Type Order No. Price
Diaphragm expansion vessel 25 l with
connection block
For ROTEX Solaris pressure systems with up to
max. 3 solar panels
MAG S 25 16 20 50 149,00
Diaphragm expansion vessel 35 l with
connection block
For ROTEX Solaris pressure systems with up to
max. 5 solar panels
MAG S 35 16 20 51 179,00
ROTEX SOLARFLUID CORACON SOL 5F
20 l can of pre-mixed solar fluid,
Functional range up to -28C
CORACON
SOL 5F
16 20 52 79,00
ROTEX SOLARFLUID CORACON SOL 5
1 l of solar fluid concentrate for extension of the
frost range. With 20 l of solar fluid with 1 l additive,
theuse range extends down to -33C
For 20 l of solar fluid with 2x 1 l of additive,
thefunctional range is extended to -38C
CORACON
SOL 5
16 20 53 15,00
Circulation lance
For energetically-optimised incorporation of the
domestic water circulation in the hot water connection
to the ROTEX storage tank.
ZKL 16 51 13 122,10
Thermostatic mixer as scalding protector
Thermal safety device for the domestic water pipe.
Setting range 35-60 C
VTA32 15 60 15 84,00
Screw connection kit 1
For connection of the scald protection VTA32
15 60 16 33,00
Thermostatic regulator 230 V
With capillary tube temperature sensor,
setting range 35-85 C
SCS-TR 16 41 30 159,00
3-way switching valve 1" male
With motor drive 230 V, switchover time 6 sec.
3 W-UV 15 60 34 115,00
119
S
o
l
a
r

h
e
a
t
i
n
g

s
y
s
t
e
m
Solar heating system
Article Type Order No. Price
RPS3 regulation and pump unit
Ready to plug in unit (230 V), with digital differential
temperature regulation, return and storage tank
temperature sensors, operational pump and pressure
increase pump.
Complete, in casing, for installation on all Solaris storage
tanks and HYC storage tanks from 2013.
INFO:
The flow sensor (FLS 20), included in the supply,
provides more effective operation of the RPS3. In
addition to direct calculation of the heat output, the
sensor allows modulation of the operating pump and
thus an additional saving in electrical energy.
Retrofitting older storage tanks:
Please contact our service department.
RPS3 16 41 25 699,00
Burner blocking contact connection cable
For RPS2, RPS3, RPS3 M, RPS3 25M.
BSKK 16 41 10 16,80
Solaris FlowGuard regulating valve
with flow rate indicator 2-16 l / min
FLG 16 41 02 69,00
Solaris connection pipe
Ready to connect connection line 15 m between solar
panel and pump station, consisting of thermally-
insulated flow and return line with
integrated sensor cable
CON 15 16 47 32 159,00
Solaris connection pipe
Ready to connect connection line 20 m between solar
panel and pump station, consisting of thermally-
insulated flow and return line with
integrated sensor cable
CON 20 16 47 33 189,00
Solaris connection pipe extension
Ready to plug in including installation material and
connection fittings
L = 2.5 m
L = 5.0 m
L = 10.0 m
Maximum possible length of the connection pipe:
Number of solar panels Max. length
2 45 m
3 30 m
4 17 m
5 15 m
CON X 25
CON X 50
CON X 100
16 42 61
16 42 62
16 42 63
98,00
112,00
149,00
Extension of the inflow pipe
UV-resistant thermally-insulated, length = 8 m,
including cable connecting fitting for the solar panel
sensor line
CON XV 80 16 42 64 139,00
On-roof roof penetration, anthracite
Roof penetration pack with connection fittings and
solar panel installation material, consisting of anthracite
roof penetration, installation material for solar panel
and connection pipe, 2 m UV-proof heat insulation for
the outer area, connection fittings with detaching tools
and panel temperature sensor
RCAP 16 20 33 279,00
Solar system for Drain-Back,
ROTEX Solaris
119
120
S
o
l
a
r

h
e
a
t
i
n
g

s
y
s
t
e
m
Solar heating system
Article Type Order No. Price
On-roof roof penetration, tile red
Roof penetration pack with connection fittings and
solar panel installation material, consisting of tile red
roof penetration, installation material for solar panel
and connection pipe, 2 m UV-proof heat insulation for
the outer area, connection fittings with detaching tools
and panel temperature sensor
RCRP 16 20 34 279,00
Solaris solar panel row connector
Connection kit for connecting two rows of solar
panels one above the other. Consisting of solar panel
installation material, equipotential bonding terminals,
end caps, connection elbows and 1 m thermally-
insulated piping
CON RVP 16 20 35 99,00
Installation material, Solaris in-roof
Ready to plug in including installation material and
connection fittings
RCIP 16 20 37 179,00
Roof penetration, flat roof
Roof penetration pack with connection fittings and
solar panel installation material, consisting of flat-roof
roof penetration, installation material for solar panel
and connection pipe, 8.5 m UV-proof heat insulation for
the outer area, connection fittings with detaching tools
and panel temperature sensor
RCFP 16 20 38 279,00
Roof penetration flat-roof for alternate side
solar panel connection
Flat roof penetration with screw connections and blind
plugs for penetration openings which are not used
CON FE 16 47 09 92,50
Solaris storage tank extension kit
Connection kit for linking two Sanicube Solaris storage
tanks (from storage tank model 2013), consisting of a
return flow connection pipe and an flow distributor line
CON SX 16 01 20 189,00
Solaris storage tank extension kit 2
Connection kit for linking additional Sanicube Solaris
storage tanks (from storage tank model 2013),
consisting of a return flow connection pipe and an flow
connection line
CON SXE 16 01 21 179,00
Circulation lance
For energetically-optimised incorporation of the
domestic water circulation in the hot water connection
to the ROTEX storage tank
ZKL 16 51 13 122,10
Thermostatic mixer as scalding protector
Thermal safety device for the domestic
water pipe. Setting range 35-60 C
VTA32 15 60 15 84,00
Screw connection kit 1
For connection of the scald protection VTA32
15 60 16 33,00
Thermostatic regulator 230 V
With capillary tube temperature sensor,
setting range 35-85 C
SCS-TR 16 41 30 159,00
3-way switching valve 1" male
With motor drive 230 V, switchover time 6 sec.
3 W-UV 15 60 34 115,00
Solar system for Drain-Back,
ROTEX Solaris
121
S
o
l
a
r

h
e
a
t
i
n
g

s
y
s
t
e
m
Solar heating system
Dimensions (W x D x H) mm 1006 x 85 x 2000 1300 x 85 x 2000 2000 x 85 x 1300
Net surface area m
2
2,01 2,60 2,60
Aperture surface area m
2
1,79 2,35 2,35
Absorbing surface area m
2
1,80 2,36 2,36
Weight kg 35 42 42
Water content Litres 1,3 1,7 2,1
Absorber Harp-shaped Cu pipe matrix with welded on
highly selective coated aluminium plate
Coating Miro-Therm (absorption max. 96%, emission approx. 5%

2%)
Glazing Single pane safety glass, Transmission approx. 92%
Heat insulation Rock wool 50mm
Max. pressure drop at 100l / h mbar 3,5 3,0 0,5
Possible pitch
min. - max.
On-roof and flat roof
15 80
Possible pitch
min. - max.
In-roof
15 80
Max. standstill temperature C approx. 200
Max. operating pressure: bar 6
The solar panels are standstill resistant over a long period and are tested for thermal shock.
Minimum collector yield over 525 kWh / m
2
per year with 40% cloud coverage (location
Wrzburg)
Solaris flat collectors V 21 P V 26 P H 26 P
Technical data
Solar system for pressurised use and Drain-Back,
ROTEX Solaris
121
122
S
o
l
a
r

h
e
a
t
i
n
g

s
y
s
t
e
m
Solar heating system
Control and pump unit RPS 3
Dimensions (W x D x H) mm 230 x 142 x 815
Operating voltage V / Hz 230 / 50
Max. electrical power consumption w 245 (modulating 20 120)
Control Digital differential
temperature controller with
clear text display
Collector sensor Pt1000
Storage tank and return sensor PTC
Feed temperature and flow sensor FLS20
Technical data
Solar system for Drain-Back,
ROTEX Solaris
123
S
o
l
a
r

h
e
a
t
i
n
g

s
y
s
t
e
m
Solar heating system
123
124
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Heat distribution
Underfloor heating systems, ROTEX Monopex,
System 70
ROTEX heat distribution systems
Monopex:
The underfloor heating for low system temperatures.
Ideal in combination with heat pumps.
Can also be used as wall heating.
Various different pipe dimensions for various different applications.
- Monopex l4 for floor structures wlth low helght, drylng system and the POTLX cut cuttlng system
- Monopex l7 for ground structure wlth system plates
- Monopex 20 for commerclal and lndustrlal surfaces
System 70:
Underfloor heating for direct combination with heating radiators or other heating surfaces.
Can also be used as wall heating.
Various different pipe dimensions for various different applications.
- DUO l3 for floor structures wlth low helght, drylng system and the POTLX cut cuttlng system
- DUO l7 for ground structure wlth system plates
- DUO 25 for commerclal and lndustrlal surfaces
125
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Heat distribution
Article Type Packaging
Unit
Order No. Price
per m
2
Price
per pack. unit
System plates Protect System plates: Styrofoam nap-plate with a protective layer made of deep drawn Polystyrene.
Overlapping connection technique of the system plates among each other. Installation dimensions 122 x 120 cm.
Suitable for heating pipe 14 and 17 mm. The routing of heating pipe can be carried out at right angles or diagonally.
Installation distance: Rectangular: 75, 150, 225, 300 mm Diagonal: 55, 110, 165, 220, 275, 330 mm
Protect-Integral 33-3
Height 48 mm
Heat conduction resistance: 0.75 m
2
K / W
Integrated thermal and step sound insulation
Installation against heated rooms.
(DES sm 040), dimensions: 1,220 x 1,200 mm
Protect 33-3 8 pieces
= 11.71 m
2
17 10 40 12,45 / m
2
145,83
Protect-Integral 33-3HKV
Reduced nap-numbers.
For using in the area of heating circuit
distributors and doorways.
Protect 33-3 HKV 2 pieces
= 2.88 m
2
17 10 43 18,75 / m
2
54,00
Protect 10
Height 28 mm
Heat conduction resistance: 0.29 m
2
K / W
For constructions with increased load and
several insulation layers.
(DEO 035), dimensions: 1,220 x 1,200 mm
Protect 10 13 pieces
= 19.03 m
2
17 10 41 8,35 / m
2
208,00
Protect 10 HKV
Reduced number of naps,
for use in the vicinity of
Heating circuit distributors and doorways.
Protect 10 HKV 3 pieces
= 4.32 m
2
17 10 44 15,97 / m
2
69,00
Protect solo
Height 18 mm
Deep-drawn expanded polystyrene plate but
without heat and sound insulation
For use in constructions with low
construction height
Only for use together with
surface primer (Order No.: 17 11 29).
Dimensions: 1,220 x 1,200 mm
Protect solo 12 pieces
= 17.57 m
2
17 10 45 8,60 / m
2
151,14
Protect mini
Height 25 mm
Heat conduction resistance: 0.20 m
2
K / W
Only suitable for heating pipes DUO 13 and
Monopex 14. Laying in structures with
low structural height.
(DEO 035), dimensions: 1,220 x 1,200 mm
Protect mini 10 pieces
= 14.64 m
2
17 10 37 8,82 / m
2
154,50
Protect mini solo
Height 17 mm
Deep-drawn expanded polystyrene plate
but without heat and sound insulation.
Only suitable for Heating pipes DUO 13 and
Monopex 14.
For use in constructions with low construction
height Only for use together with surface
primer (Order No.: 17 11 29).
Protect mini solo 10 pieces
= 14.64 m
2
17 10 38 9,46 / m
2
138,55
Underfloor heating systems, ROTEX Monopex,
System 70
125
126
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Heat distribution
Article Type Packaging
Unit
Order No. Price
per m
2
Price
per pack. unit
System plates Styrofoam nap-plate: with integrated connection technique for the system plates.
Installation dimensions: 120 x 60 cm Suitable for heating pipe 14 and 17 mm.
Heating pipe routing is carried out at right angles.
Installation distance: 75, 150, 225, 300 mm
Basis-Integral 33-3
Height 55 mm
Heat conduction resistance: 0.75 m
2
K / W
Styrofoam system plate with integrated heat
and step noise insulation.
Installation against heated rooms.
(DES sm 040), dimensions: 1,200 x 600 mm
Basis 33-3 14 pcs =
10.08 m
2
17 10 01 7,83 / m
2
109,10
Mono 15
Height 38 mm
Heat conduction resistance: 0.43 m
2
K / W
Styrofoam system plate without noise
insulation.
For use in constructions with reduced
construction height
(DES 035), dimensions: 1,200 x 600 mm
Mono 15 20 pcs =
14.40 m
2
17 10 10 5,40 / m
2
132,70
Compact 45
Height 67 mm
Heat conduction resistance: 1.28 m
2
K / W
Styrofoam system plate with increased thermal
insulation.
Installation in constructions against unheated
rooms and earth.
(DES 035), dimensions: 1,200 x 600 m
Compact 45 11 pcs =
7.92 m
2

17 10 17 18,88 / m
2
149,50
ISODUR-Plate
Height 55 mm
Heat conduction resistance: 0.85 m
2
K / W
Suitable for DUO 25 heating pipe.
Installation distance: 200, 300, 400 mm.
For industrial halls or large areas.
(DES 035), dimensions: 1,200 x 600 mm
Isodur 14 pcs =
10.08 m
2
17 10 13 10,64 / m
2
107,25
Tacker System: ROTEX tacker plate (available as folded and rolled track) with laminated,
high-strength fabric film and raster dimension (100 x 100 mm) for simple and safe installation of the heating pipes.
Film overlapping on bracket side to cover the insualtion layer.
Suitable for heating pipe 14 and 17 mm.
Installation distance: 100, 150, 200, 250, 300 mm, dynamic stiffness 15 MN / m
3
ROTEX folding plate 35-3
Height 35 mm
Heat conduction resistance: 0.78 m K / W
ROTEX tacker plate in capped version
with integrated step noise insulation.
(DES sm 045), dimensions: 1,000 x 2,000 mm
TACF 35-3 5 pcs =
10 m
2
17 45 02 5,18 / m
2
64,20
ROTEX roller track 35-3
Height 35 mm
Heat conduction resistance: 0.78 m K / W
ROTEX tacker plate in capped version
with integrated step noise insulation.
(DES sm 045), dimensions: 1,000 x 10,000 mm
TACR 35-3 1 pcs =
10 m
2
17 45 03 5,18 / m
2
64,20
Underfloor heating systems, ROTEX Monopex,
System 70
127
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Heat distribution
Article Type Packaging
Unit
Order No. Price
per m
2
/ m
Price
per pack. unit
Dry system Secco Heat conducting element
For dry construction, in profiled,
galvanized sheet steel, suitable for
Mono, Basic and Compact plate.
Installation dimensions: 120 x 37 cm
Attention:
Only the Xella screed element 2 E 22 (2x12.5 mm),
manufactured by the Xella GmbH
Element 2 E 22 (2 x 12.5 mm) by Xella GmbH approved.
Monopex secco
For Monopex 14 AL heating pipe.
WLE 14 5.35 m
2
17 11 12 30,06 / m
2
160,80
System 70 secco
For DUO 17 AL heating pipe.
WLE 17 5.35 m
2
17 11 13 32,54 / m
2
174,10
Heating pipes Monopex heating pipes
Thick-walled, linked basic PE-X pipe with oxygen-tight barrier for Monopex
low-temperature underfloor heating systems
Monopex 14
PE-X 14 x 2 DD
For Monopex underfloor heating system.
Monopex 14 50 m
120 m
240 m
600 m
17 01 57
17 00 08
17 00 09
17 00 10
1,00 / m
1,00 / m
1,00 / m
1,00 / m
64,06
153,20
306,40
765,80
Monopex 14 AL
Thick-walled PE-X basic pipe 14 x 2
Aluminium coating and PE external layer.
For Monopex underfloor heating system.
Monopex 14 AL 120 m
240 m
17 06 04
17 06 05
1,94 / m
1,94 / m
233,28
466,56
Monopex 17
PE-X 17 x 2 DD
For Monopex underfloor heating system.
Monopex 17 50 m
120 m
240 m
600 m
17 01 58
17 00 29
17 00 28
17 00 62
1,01 / m
1,01 / m
1,01 / m
1,01 / m
70,56
169,70
339,20
848,00
Monopex 20
PE-X 20 x 2 DD
For Monopex underfloor heating system.
Monopex 20 50 m
120 m
240 m
400 m
17 01 59
17 00 30
17 01 09
17 01 08
1,32 / m
1,32 / m
1,32 / m
1,32 / m
81,03
194,90
389,90
649,80
Protection pipe
Black corrugated pipe made of plastic as
additional insulation in the area of the
distributor and expansion joints.
16 / 21 mm
19 / 25 mm
23 / 28 mm
Protection pipe
Protection pipe
Protection pipe
25 m
25 m
75 m
17 00 98
17 00 53
17 00 01
0,64 / m
0,76 / m
0,92 / m
16,00
19,00
69,00
Underfloor heating systems, ROTEX Monopex,
System 70
127
128
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Article Type Packaging
Unit
Order No. Price
per m
2
/ m
Price
per pack. unit
Heating pipes DUO heating pipes
Thick-walled, linked basic PE-X pipe with oxygen-tight barrier and additional high-flexibility PE spaced sleeve pipe.
For underfloor heating which are operated in direct combination with other heating surfaces
e.g. radiators. Reg. No. 3 V 292 PE-X
DUO 13
PE-X 13.7 / 9.7 x 1.3 DD
For construction with reduced headroom.
DUO 13 120 m
240 m
17 90 11
17 90 12
1,83 / m
1,83 / m
216,97
433,89
DUO 17
PE-X 17 / 12 x 2 DD
For System 70 underfloor heating and
Heating radiator connection.
DUO 17 50 m
120 m
240 m
600 m
17 01 60
17 00 68
17 00 86
17 00 61
2,14 / m
2,14 / m
2,14 / m
2,14 / m
107,44
257,85
515,75
1.289,25
DUO 17 AL
PE-X 17 / 12 x 2
With Aluminium sheathing and PE external layer.
For System 70 radiator connection and
underfloor heating.
DUO 17 AL 60 m
120 m
240 m
17 06 21
17 06 01
17 06 02
2,46 / m
2,46 / m
2,46 / m
148,01
296,03
592,11
DUO 25
PE-X 25 / 18 x 2 DD as DUO 17,
for System 70 industrial underfloor heating.
DUO 25 200 m
400 m
17 00 50
17 01 05
2,82 / m
2,82 / m
563,92
1.127,79
Edge insulation strip for cement or
anhydrite screeds
PE-foam with welded foil,
Height 150 mm, thickness 8 mm.
RDS 25 m 17 11 01 0,76 / m 18,90
Edge insulation strip for flow screeds
PE-foam with welded foil,
and additional sealing cord.
Height 150 mm, thickness 10 mm.
RDS-FP 25 m 17 11 26 1,60 / m 40,10
Edge insulation strip for concrete structures
PE-foam with welded foil,
Height 300 mm Thickness 10 mm
(industrial applications).
RDS-i 25 m 17 11 09 1,32 / m 33,00
Edge insulating strip
For System 70 mini and wall heating.
Self-adhesive.
Height 70 mm, thickness 5 mm.
RDS-M 25 m 17 11 31 0,47 / m 11,85
Expansion joint profile
For the production of move joints and
joints at doorways.
Waxed corrugated cardboard with adhesive film.
Length 100 cm, Total height 10 cm,
Set height 7 cm, Thickness 6 mm.
DFP 25 m 17 11 08 4,48 / m 112,10
Underfloor heating systems, ROTEX Monopex,
System 70
Heat distribution
129
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Heat distribution
Underfloor heating systems, ROTEX Monopex,
System 70
Article Type Packaging
Unit
Order No. Price
per kg / piece
Price
per pack. unit
Screed additive
Cement screed with 45 mm
heating pipe covering
Heating beginning after 21 days
Addition quantity approx. 0.150 kg / m
2

Estrolith
H2000
10 kg 17 11 02 3,55 / kg 35,45
Screed additive
Cement screed with 45 mm
heating pipe covering
Heating beginning after 10 days
Addition quantity approx. 0.250 kg / m
2

Temporex 10 kg 17 11 11 5,65 / kg 56,45
Screed additive
Cement screed with 30 mm
heating pipe covering
Heating beginning after 21 days
Addition quantity approx. 1.3 kg / m
2

Estrotherm
S
10 kg 17 11 06 5,70 / kg 57,00
Screed additive
For System 70 mini solo,
0,5 kg / m
2
.
Staboform 20 kg 17 11 30 15,03 / kg 300,60
Surface primer
For Protect mini solo,
0.45 kg / m
2
.
Surface
primer
3.5 kg
15 kg
17 11 32
17 11 29
28,37 / kg
28,37 / kg
99,30
425,60
Frost and corrosion protection
Addition quantity:
With frost protection up to
- 10 C: approx. 20 Vol.% of heating water capacity
- 14 C: approx. 25 Vol.% of heating water capacity
- 18 C: approx. 30 Vol.% of heating water capacity
NALCO CW-
143
25 kg 17 11 03 12,34 / kg 308,50
ROTEX system tacker
Precise wear-resiatant tool for processing the
tacker needles TN40 contained in a magazine.
With curved magazine and ergonomically-shaped
handle.
Unit without support leg.
STAC 17 11 34 Net
270,00
ROTEX Tacker needle
For ROTEX system tacker for fixing
and location of the ROTEX pipes up to max.20
mm. Colour black, 30 in number, each in maga-
zine, packed in a cardboard box.
TN40 300 pcs 17 11 35 0,06 / piece 17,10
Transparent adhesive strip
Transparent plastic adhesive strip for sealing and
gluing the tacker plates.
Width: 50 mm; Length: 66 m
1 roll for approx. 50 m.
KB50 6 pcs 17 11 36 4,83 / piece 29,00
Hand dispenser for adhesive strip
ROTEX hand dispenser for simple dispensing
and processing the adhesive strip.
HAR 17 11 33 Net
32,90
129
130
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Heat distribution
Article Type Packaging
Unit
Order No. Price
per pack. unit
RMX heating circuit distributor for all ROTEX underfloor heating system
and radiator connection systems
- Heat stabilised glass fibre reinforced polyamide
- Suitable for the smallest fitting heights
- Space-saving by reduced module width
- Can be extended flexibly by modular design
- For 2 to 14 heating circuits
- Eurocone connection up to 20 mm pipe diameter
- Integrated flow rate measurement
- Integrated KFE connection group and thermometer
Dimensions in cm
(height x width)
2 fold distributor 44 x 20 RMX 2 1 17 27 02 145,60
3 fold distributor 44 x 25 RMX 3 1 17 27 03 170,90
4 fold distributor 44 x 30 RMX 4 1 17 27 04 201,50
5 fold distributor 44 x 35 RMX 5 1 17 27 05 231,10
6 fold distributor 44 x 40 RMX 6 1 17 27 06 261,70
7 fold distributor 44 x 45 RMX 7 1 17 27 07 291,10
8 fold distributor 44 x 50 RMX 8 1 17 27 08 321,70
9 fold distributor 44 x 55 RMX 9 1 17 27 09 351,30
10 fold distributor 44 x 60 RMX 10 1 17 27 10 381,90
11 fold distributor 44 x 65 RMX 11 1 17 27 11 411,40
12 fold distributor 44 x 70 RMX 12 1 17 27 12 442,00
Extension kit for one heating circuit
(for flow and return)
RMX-EWS 2 1 17 27 20 35,05
Clamping ring kit on heating circuit
distributor RMX
For forward and return of each circuit
For DUO heating pipe 17 / 12 x 2 MV 12 1 Set 17 03 12 9,40
For DUO heating pipe 13.7 / 9.7 x 1.32 MVS 9.7 1 Set 17 03 10 12,30
For Monopex heating pipe 14 x 2 MV 14 1 Set 17 03 14 7,45
For VA-Stab heating pipe 16 x 2.2 MV 16 1 Set 17 03 15 9,40
For Monopex heating pipe 17 x 2 MV 17 1 Set 17 03 17 6,30
For DUO heating pipe 25 / 18 x 2 MV 18 1 Set 17 03 18 7,65
For Monopex 20 x 2 MV 20 1 Set 17 03 20 8,35
Connection nipple " male x "
Self-seallng wlth thread-cuttlng seal, " Lurokonus.
For establishing threaded PEX pipe connections
in conjunction with MV series clamping ring kit.
ARU 2 pieces. 17 73 27 6,50
Coupling nipple " Eurocone
For establishing PEX pipe couplings
in conjunction with MV series clamping ring kit.
SKU 2 pieces. 17 72 27 11,65
Ball-cock kit
1" female thread x 1" male thread
ASH3 2 pieces. 17 55 14 27,85
Underfloor heating systems, ROTEX Monopex,
System 70
131
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Heat distribution
Underfloor heating systems, ROTEX Monopex,
System 70
Article Type Pack size Order No. Price
per pack. unit
Heating circuit distributor HKV QuickFix Industry
Made of heat stabilized polyamide, glasfiber reinforced, hot water resistant, suitable for all ROTEX under floor heating and
radiator connection systems, with fast mounting system, incl. hand bleeding, inscription labels and fitting spanner.
2 fold distributor HKV 2 1 17 25 02 139,00
3 fold distributor HKV 3 1 17 25 03 159,00
4 fold distributor HKV 4 1 17 25 04 189,00
5 fold distributor HKV 5 1 17 25 05 209,00
6 fold distributor HKV 6 1 17 25 06 240,45
7 fold distributor HKV 7 1 17 25 07 257,85
8 fold distributor HKV 8 1 17 25 08 283,90
9 fold distributor HKV 9 1 17 25 09 309,35
10 fold distributor HKV 10 1 17 25 10 337,45
11 fold distributor HKV 11 1 17 25 11 363,60
12 fold distributor HKV 12 1 17 25 12 391,00
13 fold distributor HKV 13 1 17 25 13 417,80
14 fold distributor HKV 14 1 17 25 14 443,95
Connection kit for HKV 2 to HKV 14 ASH 1 1 17 55 10 92,85
Clamping ring set
For forward and return of each circuit
For DUO heating pipe 17 / 12 x 2 E 1 1 Set 17 70 12 7,35
For Monopex heating pipe 14 x 2 E 2 1 Set 17 70 14 7,65
For VA-Stab heating pipe 16 x 2.2 E 7 1 Set 17 70 10 9,00
For Monopex heating pipe 17 x 2 E 4 1 Set 17 70 17 7,65
For DUO heating pipe 17 / 12 x 2 E 5 1 Set 17 70 18 7,65
For Monopex heating pipe 20 x 2 E 6 1 Set 17 70 20 11,00
For DUO heating pipe 13.7/9.7 x 1.3 S 1 1 Set 17 04 10 11,40
Isolation plug set for HKV
For unused heating circuits
1 17 70 30 2,10
Heat counter set
Suitable for heat quantity counter
110 or 130 mm in length.
Suitable for HKV 2 to HKV 14
and RMX 2 to RMX 14.
WMS 1 17 60 20 150,00
131
132
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Heat distribution
Underfloor heating systems, ROTEX Monopex,
System 70
Article Type Pack size Order No. Price
Combo-Box
Sub-distribution for romm-wise distribution and
regulation for max. 2 underfloor heating circuits with
System 70 for DUO 13 and DUO 17 heating pipe, and,
if selected, one radiator complete with UP housing
including adapter plates, without clamping ring kit
and setting drive (only SAT 5 possible). All connections
Eurokonus. Valve block and clamping ring kit for
connecting a radiator to be ordered separately, if
required.
Combo-Box 1 pieces. 17 24 15 189,00
Clamping ring kit for Combo-Box
Eurokonus DUO 13.7 / 9.7 x 1.3
MVS 9.7 1 Set 17 03 10 12,30
Clamping ring kit for Combo-Box
Eurokonus DUO 17 / 12 x 2
MV 12 1 Set 17 03 12 9,40
Wall mounting box
With front frame and door, height adjustable
from 80 to 120 mm, frame and door powder-
coated RAL 9010 white
up to HKV / RMX 4
up to HKV / RMX 7
up to HKV / RMX 10
up to HKV / RMX 14
up to HKV 14 with heat counter set
Dimensions in cm
(H x W)
WEK RMX 05 (75 x 50)
WEK RMX 10 (75 x 75)
WEK RMX 15 (75 x 90)
WEK RMX 20 (75 x 120)
WEK RMX 25 (75 x 150)
1
1
1
1
1
17 81 05
17 81 10
17 81 15
17 81 20
17 81 25
113,20
132,10
149,70
167,00
200,75
Distributor cabinet for surface mounting
Powder-coated white RAL 9016,
Dimensions as for WEK
up to HKV 7
up to HKV 10
up to HKV 14
APK 110 (66.5 x 75)
APK 115 (66.5 x 90)
APK 120 (66.5 x 120)
APK 125 (66.5 x 150)
1
1
1
1
17 41 10
17 41 15
17 41 20
17 41 25
173,80
191,70
219,40
253,10
Distributor cabinet for wall front installation
of the HKV (industrial sector)
up to HKV 7
up to HKV 14
WEK 40 (75 x 110)
WEK 45 (75 x 140)
1
1
17 71 40
17 71 45
243,60
277,30
Fixing frame console
Suitable for WEK 40
Suitable for WEK 45
STK 40
STK 45
1
1
17 72 41
17 72 46
232,10
253,10
133
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Heat distribution
Room regulation for underfloor heating systems, ROTEX Monopex,
System 70
Article Type Pack size Order No. Price
RoCon UFH room regulator wired
Particularly flat surface mounting.
Characteristics:
- Stepless setting range 5 26C
- Can be deactivated (frost protection function
active)
- Display of heating demand (rot) and cooling
demand (blue)
- Wiring with telephone cable
- 5 V power supply of RoCon RM
UFH-RD 1 17 51 39 35,00
RoCon UFH regulator module wired, for 6
channels
Characteristics:
- 6 channels
- 4 setting drives (230 V) per channel
- 5 V output for room regulator
- Automatic switching heating / cooling of all
connected Room controller.
- Fuse
UFH-RMD6 1 17 51 40 159,00
RoCon UFH regulator module wired, for 2
channels
Characteristics:
- 2 channels
- 4 setting drives (230 V) per channel
- 5 V output for room regulator
- Automatic switching heating / cooling of all
connected Room controller.
- Fuse
UFH-RMD2 1 17 51 41 79,00
RoCon UFH room regulator radio
Particularly flat surface mounting for use with
the regulator modules RMF6A /RMF2A.
Characteristics:
- Stepless setting range 5 26C
- Can be deactivated (frost protection function
active)
- Solar cell no battery required
UFH-RFT 1 17 51 42 169,00
RoCon UFH regulator module radio, for 6
channels
Characteristics:
- 6 channels
- 4 setting drives (230 V) per channel
- Automatic switching heating / cooling of all
connected Room controller
- Fuse
- Including antenna
UFH-RMF6A 1 17 51 43 299,00
RoCon UFH regulator module radio, for 2
channels
Characteristics:
- 2 channels
- 4 setting drives (230 V) per channel
- Automatic switching heating / cooling of all
connected Room controller
- Fuse
- Including antenna
UFH-RMF2A 1 17 51 44 199,00
133
134
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Heat distribution
Room regulation for underfloor heating systems, ROTEX Monopex,
System 70
Article Type Pack size Order No. Price
RoCon UFH mains unit module
Basic module with integrated mains unit for
supplying the regulator module (radio and
wired) and reception possibilities of the clock
module.
Characteristics:
- Pump output for heating demand
- Pump output for cooling demand
- Cascading output
- Input for switching heating / cooling
- Fuse
UFH-BM 1 17 51 37 149,00
RoCon UFH clock module
Clock module for rxtension of the basic module.
- 2 setback times for heating circuits
- Pump overrun period
- For ease of operation, removeable from
the basic module
UFH-UM 1 17 51 38 79,00
Setting drive for RMX
Currentless closed with function display,
Connection line length 1 m, 230 V,
connection thread M 30 x 1.5
UFH-Sat8 1 17 51 45 19,00
135
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Heat distribution
Room regulation for underfloor heating systems, ROTEX Monopex,
System 70
Article Type Pack size Order No. Price
Room temperature control
heating / cooling 230 V
RTK 1 17 51 25 39,40
Electronic room temperature regulator
heating 230 V
RTR-5 1 17 51 17 28,85
Room temperature regulator 230 V
adapter frame
RTR4
ARA-E1S
1
1
17 51 11
17 51 13
24,20
3,00
Room temperature regulator 230 V
With clock timer
RTZ 1 1 17 51 12 153,00
Universal setting drive for HKV,
Combo-Box and RMX
230 V, closed when current-free, plug
mounting, function display visible from
all angles, connection line length 1 m,
First Open Function, energy-saving as a
result of low power consumption (1.8 W),
M30 x 1.0, valve adaption for M30 x 1.5 is
possible
(please use the valve adapter 175110.02).
SAT 5 1 17 51 10 24,00
Setting drive for RMX
Currentless closed with function display,
connection line length 1 m, 230 V,
connecting thread M 30 x 1.5.
SAT 6 1 17 51 14 19,00
Valve adapter
For mounting the setting drive SAT 5 on
thermostatic valves.
Va 1 17 51 10.02 2,10
Cannot be combined with
RoCon UFH room regulation
135
136
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Heat distribution
Underfloor heating systems, ROTEX Monopex,
System 70
Article Type Packaging
Unit
Order No. Price
per m / piece
Price
per pack. unit
Basic cable terminal block
For connection of 6 RTR and
max.14 SAT.
KKL-1 1 17 51 31 83,85
Pump module for KKL
230 V
PM 1 17 51 34 85,40
Cable terminal block extension
For extension of the basis cable clamping
block by 2 RTR to a total of 8 RTR
with max.14 SAT.
KKL-2 1 17 51 32 34,30
Wireless room temperature control
Currentless closed with function
display, connection line length 1 m,
230 V, connecting thread M30 x 1.5.
FRT 1 17 51 20 104,45
Reception module, 4-channel
230 V / 50 Hz for regulating 1 or
more setting drives per channel
(for up to 4 FRT).
FEM-1 1 17 51 21 118,15
Reception module, 4-channel
230 V / 50 Hz for regulating 1 or
more setting drives per channel
(for up to 4 FRT).
FEM-4 1 17 51 22 208,90
Accessories wall heating
Clip rails
Rail length: 1 m
Pipe spacing: 50 mm
100 m 17 12 24 3,75 / m 375,45
Plastic nail
For clip rail.
Length 60 mm
Shaft diameter: 8 mm
KN06 100 in number 17 11 27 0,37 / piece 36,90
Plastic expansion plug
For system plate Protect mini
and mini solo.
Length 75 mm
Shaft diameter: 8 mm
KSD75 20 in number 17 11 28 0,69 / piece 13,70
Tools
Combined pipe cutter and
stripping pliers with calibration mandrel
For DUO and AL heating pipes.
RAZ 1 1 17 11 10 Net
108.50
Cutting device
For Protect-System plate.
SV 1 17 11 15 25,00
Open ring spanner SW 19 / 22 QRS 1 17 22 20 25,00
137
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Heat distribution
Underfloor heating systems, ROTEX Monopex,
System 70
Article Type Packaging
Unit
Order No. Price
per item
Price
per pack. unit
Pipe unwinder
For 120 m and 240 m coils,
swivelling 360.
RAW 240 1 17 10 06 459,00
net
For 600 m in coils
and 200 / 400 m in coils.
For DUO 25 and Monopex 20.
RAW 600 1 17 10 07 679,00
net
Accessories
Pipe fixing clips
For Monopex 17 and 20 as well as Duo 25
heating pipes and protection pipe 19/25
RHC 17
RHC 25
50
50
17 11 17
17 11 25
0,15 / piece
0,22 / piece
7,45
15,00
Pipe fixation
For fixing the heating pipes
to the steel armouring
BD 1000 17 01 45 0,05 / piece 52,75
Binding unit
For fixing twisting of the pipe fixing
BA 1 17 01 40 25,00
137
138
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Heat distribution
Underfloor heating systems, ROTEX Monopex,
System 70
Calculation prices wet systems: Gross price overview for 1 m
2
underfloor heating
In price included material: 1 m
2
system plate, 1 m edge insulation strip, screed additive, piping quantity
depending on installation pattern (3 tacker needles per metre of pipe, additional insulation necessary on site).
Heating pipe
Type
100 mm
10 m / m
2
150 mm
6.7 m / m
2
200 mm
5 m / m
2
300 mm
3.3 m / m
2
1. Construction against heated rooms
Tacker-System 35-3
Monopex
2)
Monopex
3)
Monopex 17
Monopex 14
22,70
21,32
18,03
17,11
15,62
14,94
13,22
12,77
Total construction height with 45 mm screed over pipe 94 mm (91 mm
3)
)
2. Construction against ground
and unheated rooms
(in accordance with EnEV / DIN / EN 1264)
(Additional insulation EPS DEO 040
must be provided by customer)
Monopex
2)
Monopex
3)
Monopex 17
Monopex 14
22,70
21,32
18,03
17,11
15,62
14,94
13,22
12,77
Total construction height with 45 mm screed over pipe 114 mm (111 mm
3)
)
Heating pipe
Type
75 mm
13 m / m
2
150 mm
6.7 m / m
2
225 mm
4.4 m / m
2
300 mm
3.3 m / m
2
3. Construction against heated rooms
Protect-Integral 33-3
System 70
1)
Monopex
2)
Monopex
3)
DUO 17
Monopex 17
Monopex 14
42,52
32,97
31,18
28,98
24,06
23,14
24,04
20,81
20,20
21,68
19,25
18,80
Total construction height with 45 mm screed over pipe 90 mm (87 mm
3)
)
4. Construction against ground
and unheated rooms
Compact 45
DUO 17
Monopex
2)
Monopex
3)
DUO 17
Monopex 17
Monopex 14
48,94
39,39
37,61
35,41
30,49
29,56
30,46
27,23
26,63
28,10
25,68
25,22
Total construction height with 45 mm screed over pipe 108 mm (105 mm
3)
)
5. Construction against heated rooms
Basis-Integral 33-3
System 17:
Monopex
2)
Monopex
3)
DUO 17
Monopex 17
Monopex 14
40,89
31,34
29,55
27,35
22,43
21,51
22,41
19,18
18,57
20,05
17,62
17,17
Total construction height with 45 mm screed over pipe 94 mm (91 mm
3)
)
6. Construction against heated rooms
Protect 10
System 17:
Monopex
2)
Monopex
3)
DUO 17
Monopex 17
Monopex 14
41,00
31,45
29,66
27,46
22,54
21,62
22,52
19,29
18,68
20,15
17,73
17,28
Total construction height with 45 mm screed over pipe 70 mm (67 mm
3)
)
Calculation prices System Protect mini: Gross price overview for 1 m
2
underfloor heating
In price included material: 1 m
2
system plate, 1 m edge insulation strip, screed additive, adhesive base,
Quantity of pipe in accordance with routing raster
Heating pipe
Type
75 mm
13 m / m
2
150 mm
6.7 m / m
2
225 mm
4.4 m / m
2
300 mm
3.3 m / m
2
7. Low construction for new and
Renovation
Protect mini
System 70 mini
1)
Monopex
3)
DUO 13 / 9.7 x 1.3
Monopex 14 x 2
38,80
31,89
27,40
23,84
23,25
20,91
21,26
19,50
Total installation height with 30 mm screed over pipe 53 mm
8. Construction on existing
screeds or stone coverings
Protect mini solo
System 70 mini
1)
Monopex
3)
DUO 13 / 9.7 x 1.3
Monopex 14 x 2
47,09
40,18
35,70
32,14
31,54
29,20
29,55
27,80
Total installation height with 12 mm screed over pipe 27 mm
1)
Underfloor heating system and radiator are operated with the same heating water temperature
2)
Additional radiators need a second water distribution with recirculation pump, mixer, ascending pipe section and corresponding control
3)
For Monopex 14 underfloor heating system
139
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Heat distribution
Underfloor construction wet system
Underfloor heating systems, ROTEX Monopex,
System 70
1. Construction against heated rooms
Tacker-System 35-3
2. Construction against ground and unheated rooms
Tacker system 35-3 and additional insulation EPS DEO 040
3. Construction against heated rooms
Protect-Integral 33-3
5. Construction against heated rooms
Basis-Integral 33-3
4. Construction against ground and unheated rooms
Compact 45
6. Construction against heated rooms
Protect 10
Floor constructions System Protect mini
7. Low construction for new and renovated buildings
Protect mini
8. Construction on existing grout or stone covering surfaces
Protect mini solo
These constructions are a recommendation of EN 1264 T4 and can be used
for buildings which meet with the requirements of the maximum year-
primary energy requirements according to EnEV.
In buildings which are not planned according to EnEV, there is a demand
for separate proof according to DIN 4108-6.
Specification has to be done by building planner
a Construction to be sealed in accordance with DIN 18195
b PE film against residual moisture from the ceiling
c Additional insulation EPS DEO 040 to be provided by customer
d Surface primer
139
140
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Heat distribution
Underfloor heating systems, ROTEX Monopex,
System 70
length-related pressure drop for the heating pipes 9, 7, 12, 14, 17, 18 and 20 mm
Fliegeschwindigkeit in m/s
1
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
9
0
1
0
0
2
0
0
3
0
0
4
0
0
5
0
0
6
0
0
7
0
0
8
0
0
9
0
0
1
0
0
0


Durchfluss in l/h
l

n
g
e
n
b
e
z
o
g
e
n
e
r

D
r
u
c
k
a
b
f
a
l
l

i
n

P
a
/
m
1000
900
800
700
600
500
400
300
200
100
90
80
70
60
50
40
30
20
10
9
,
7

x

1
,
3
m
m

D
U
O

1
3
1
2
x

2

m
m

D
U
O

1
7
1
8

x

2

m
m

D
U
O

2
5
2
0

x

2

m
m
Speed of flow in m/s
Flow rate in l/h

L
e
n
g
t
h
-
r
e
l
a
t
e
d

p
r
e
s
s
u
r
e

d
r
o
p

i
n

P
a
/
m
141
H
e
a
t

d
i
s
t
r
i
b
u
t
i
o
n
Heat distribution
141
142
I
n
s
t
a
l
l
a
t
i
o
n

S
y
s
t
e
m
Installation system
VA Installation system
ROTEX VA
- |nstallatlon system ln slldlng sleeve technology
- Por sanltatlon and heatlng
- Absolutely no corroslon of flttlngs or slldlng sleeves
- No metal lons ln the drlnklng water
- Large, free passage - low pressure drop
- Preventlon of deposlts
- Lasy handllng
- O-rlng free, long-term seallng
- 8aslc plpe approved ln accordance wlth DvGw
- Approved for drlnklng water
143
I
n
s
t
a
l
l
a
t
i
o
n

S
y
s
t
e
m
Installation system
VA Installation system
Article Type Pack size Order No. Price per m Price per pack
VA Stab installation pipe DIN-registered, thick-walled PEX basic pipe with blunt-welded
aluminium coat and silver-grey PE-external layer.
Pipe VA 12 x 2 60 m coil 17 06 30 1,62 / m 97,25
Pipe VA 16 x 2.2
Pipe VA 16 x 2.2
120 m coil
30 rods, 4 m each
17 06 08
17 06 09
2,24 / m
2,40 / m
269,05
288,05
Pipe VA 20 x 2.8
Pipe VA 20 x 2.8
100 m coil
20 rods, 4 m each
17 06 10
17 06 11
3,02 / m
3,26 / m
302,15
261,15
Pipe VA 25 x 3.5
Pipe VA 25 x 3.5
50 m coil
15 rods, 4 m each
17 06 46
17 06 12
4,71 / m
4,98 / m
235,35
298,75
Pipe VA 32 x 4.4 10 rods, 4 m each 17 06 29 7,12 / m 284,70
Pipe VA 16 x 2.2
pre-insulated with
9 mm
50 m coil 17 06 22 3,54 / m 176,85
Pipe VA 20 x 2.8
pre-insulated with
9 mm
50 m coil 17 06 23 4,44 / m 222,20
Aluminium 0.2 mm
Laser butt welded
100 % impervious to oxygen diffusion
PE-X basic pipe
Adhesion agent
(Primer)
Adhesion agent
(Primer)
PE protection layer
UV stabilised
143
144
I
n
s
t
a
l
l
a
t
i
o
n

S
y
s
t
e
m
Article Dimensions in mm Pack-
aging
Unit
Order No. Price each Price
per pack
A B C D
The plastic fittings are made of high-quality plastic for the connection of VA-Stab pipes in sliding sleeves
technique. The fittings are mechanically, chemically and thermally extremely load-resistant and they are
characterised by high stress crack-resistant and thermal ageing stability.
Approved to DVGW W-534. Reg.No. DW-8501 BL 0524
Bow 90
16 x 2.2
20 x 2.8
25 x 3.5
32 x 4.4
22,5
24,5
27
36
20
10
10
5
19 50 71
19 50 72
19 50 73
19 50 74
2,36 / piece
2,61 / piece
4,02 / piece
8,72 / piece
47,10
26,10
40,20
43,60
Bow 45
25 x 3.5
32 x 4.4
23
25
5
5
19 50 75
19 50 76
5,92 / piece
7,92 / piece
29,60
39,60
Coupling
12 x 2
16 x 2.2
20 x 2.8
25 x 3.5
32 x 4.4
16
16
16
16
20
20
20
15
10
5
19 50 80
19 50 81
19 50 82
19 50 83
19 50 84
1,51 / piece
1,50 / piece
2,07 / piece
4,09 / piece
6,27 / piece
30,20
30,00
31,05
40,90
31,35
Coupling reduced
20 16
25 16
25 20
16 12
20 12
32 25
16
16
16
16
16
16
10
10
10
10
10
5
19 50 91
19 50 92
19 50 93
19 50 94
19 50 95
19 50 96
2,26 / piece
3,13 / piece
3,15 / piece
1,76 / piece
2,28 / piece
5,01 / piece
22,60
31,25
31,45
17,55
22,80
25,05
T-piece equal
16 16 16
20 20 20
25 25 25
32 32 32
45
49
54
72
22,5
24,5
27
36
10
10
10
5
19 51 01
19 51 02
19 51 03
19 51 04
2,53 / piece
3,36 / piece
4,90 / piece
12,96 / piece
25,20
33,60
48,95
64,80
T-piece reduced
20 16 16
20 16 20
20 20 16
16 12 12
16 12 16
20 12 20
25 16 25
25 20 25
25 20 20
20 25 20
25 32 25
32 25 32
32 25 25
46
46
48
44
45
45
46
48
48
56
68
61
59
24
24
24
24
24
25
27
27
27
24
30,5
34
34
23
23
24
23
18,5
22,5
23
24
24
28
34
30
30,5
10
10
10
10
10
10
10
10
10
10
5
5
5
19 51 11
19 51 12
19 51 13
19 51 17
19 51 14
19 51 15
19 51 21
19 51 22
19 51 23
19 51 16
19 51 24
19 51 28
19 51 29
3,22 / piece
3,18 / piece
3,50 / piece
2,61 / piece
2,74 / piece
3,56 / piece
4,30 / piece
4,53 / piece
4,05 / piece
4,35 / piece
9,46 / piece
10,20 / piece
10,76 / piece
32,15
31,75
34,95
26,10
27,40
35,55
43,00
45,25
40,50
43,50
47,30
51,00
53,80
Manifold two-fold
16 x 2.2
20 x 2.8
50
50
25
25
30
30
4
4
19 51 40
19 51 42
6,19 / piece
7,09 / piece
24,75
28,35
Manifold three-fold
16 x 2.2
20 x 2.8
50
50
25
25
30
30
4
4
19 51 41
19 51 43
9,08 / piece
10,03 / piece
36,30
40,10
VA Installation system
Installation system
145
I
n
s
t
a
l
l
a
t
i
o
n

S
y
s
t
e
m
Installation system
Article Dimensions in mm Pack-
aging
Unit
Order No. Price each Price
per pack
A B C D
Blanking plug kit 75 23,5 4 19 51 44
7,68 / piece 30,70
Connection set 50 23,5 4 19 51 45 8,04 / piece 32,15
Connection kit
elbow
3 / 4 female thread 52 29,5 75 23,5 4 19 51 46 14,71 / piece 58,85
Connection set
elbow
20 x 2.8
30 27,5 75 23,5 4 19 51 47 10,00 / piece 40,00
Connection kit
straight
3 / 4 female thread 49 75 23,5 4 19 51 48 11,85 / piece 47,40
Connection set
straight
20 x 2.8 21

75 23,5 4 19 51 49 8,43 / piece 33,70
Wall bracket 90
female
16 x 1 / 2
20 x 1 / 2
20 x 3 / 4
46
46
51
30
30
33

10
10
5
19 51 31
19 51 32
19 51 33
5,97 / piece
7,02 / piece
13,25 / piece
59,65
70,15
66,25
Transition bracket
90 female
16 x 1 / 2
20 x 1 / 2
30
30
30
30








5
5
19 50 13
19 50 12
4,87 / piece
5,59 / piece
24,35
27,95
Transition T-piece
90 female
16 1 / 2 (female) -16
20 1 / 2 (female) -20
25 1 / 2 (female) -25
25 3 / 4 (female) -25
52
52
60
66
30
30
32,5
38











5
5
5
5
19 50 21
19 50 22
19 50 23
19 50 24
6,84 / piece
8,22 / piece
11,11 / piece
11,79 / piece
34,20
41,10
55,55
58,95
Transition angle
90 female UPS
Geberit
+ nut
16 x 1 / 2
19 33,5 9

5 19 50 31 8,97 / piece 44,85
VA Installation system
145
146
I
n
s
t
a
l
l
a
t
i
o
n

S
y
s
t
e
m
Installation system
Article Dimensions in mm Pack-
aging
Unit
Order No. Price
each
Price
per pack
A B C D

Sliding sleeve
VA pipe
12 x 2
20,5 15 12,9 50 19 50 60 0,68 / piece 33,80
16 x 2.2 23,6 15 17,5 50 19 50 61 0,63 / piece 31,65
20 x 2.8 28 18 21,6 50 19 50 62 0,76 / piece 38,05
25 x 3.5 34 22 26,6 50 19 50 63 1,12 / piece 55,95
32 x 4.4 44 27 34 25 19 50 64 2,05 / piece 51,20
Brass mould parts made of dezincification resistant brass

Transition angle
90 male
16 1 / 2
20 1 / 2
25 3 / 4
23
23
26
35,5
35,5
40
14
14
14
10
10
5
19 50 01
19 50 02
19 50 03
7,60 / piece
8,91 / piece
13,50 / piece
75,95
89,10
67,50
Threaded piece
male
12 3 / 8
12 1 / 2
16 3 / 8
16 1 / 2
20 1 / 2
20 3 / 4
20 1
25 3 / 4
25 1
32 1
33
33
33
33
33
33
33
35
35
37
15
15
15
15
18
18
18
22
22
27
10
5
10
10
10
5
5
10
5
5
19 50 36
19 50 47
19 50 37
19 50 41
19 50 42
19 50 48
19 50 49
19 50 44
19 50 45
19 50 46
6,15 / piece
5,81 / piece
6,45 / piece
5,38 / piece
6,06 / piece
7,38 / piece
8,92 / piece
7,60 / piece
8,86 / piece
11,62 / piece
61,50
29,05
64,50
53,80
60,60
36,90
44,60
75,95
44,30
58,10
Transition piece
female
16 1 / 2
20 1 / 2
20 3 / 4
20 1
25 3 / 4
32
32
34
34
34
10
10
10
5
5
19 50 51
19 50 52
19 50 53
19 50 57
19 50 56
5,70 / piece
7,23 / piece
8,28 / piece
7,73 / piece
8,90 / piece
57,00
72,25
82,75
38,65
44,50
VA Installation system
147
I
n
s
t
a
l
l
a
t
i
o
n

S
y
s
t
e
m
Installation system
Article Dimensions in mm Packag-
ing
Unit
Order No. Price
each
Price
per pack
A B C D

Transition with
spigot nut
16 3 / 4
16 1
20 3 / 4
20 1
25 1
32 1
32 1
1
/ 4
19
19
19
19
18
23
23
10
5
10
5
5
5
5
19 51 65
19 51 60
19 51 66
19 51 61
19 51 62
19 51 63
19 51 64
10,78 / piece
10,45 / piece
13,98 / piece
11,11 / piece
11,91 / piece
14,71 / piece
28,43 / piece
107,75
52,25
139,80
55,55
59,55
73,55
142,15
The ROTEX VA mounting guide rail are made of galvanised sheet steel.
Their stable and torsionproof design makes them suitable for almost all applications,
self-cutting threaded screws included in the delivery.

Mounting bracket
Double
153 120 100 76,5 1 19 51 35 11,70
Single 150 14 1 19 51 36 9,05
Universal 270 120 1 19 51 37 12,00
VA Installation system
147
148
I
n
s
t
a
l
l
a
t
i
o
n

S
y
s
t
e
m
Installation system
Article Type Packaging
Unit
Order No. Price
Tools
AX-Press 25
Battery-powered machine with automatic return motion,
for axial mounting of ROTEX sliding sleeves.
With li-ion battery 14.4 V, 1.6 Ah, quick charger and
sliding jaws for pipes dia. 16, 20, 25, 32 mm.
AX25 1 19 51 70 Net
726,00
EX-Press-P
Battery-powered pipe expander with automatic
return motion, for expanding ROTEX VA pipes.
With li-ion battery 14.4 V, 1.6 Ah, quick charger
and sliding jaws for pipes dia. 16, 20, 25, 32 mm.
EXP 1 19 51 71 Net
726,00
Basic set AX-Press 25 + EX-Press-P
Battery-powered machine with automatic return motion,
for axial mounting of ROTEX sliding sleeves + battery-powered
pipe expander with automatic return motion, for expanding
ROTEX VA pipes. With li-ion battery 14.4 V, 1.6 Ah,
quick charger and sliding jaws + expanding heads
for pipes dia. 16, 20, 25, 32 mm.
AX+EXP 1 19 51 72 Net
1.324,00
Expanding head
For ROTEX VA pipe 12 mm.
RO VA 12 1 19 51 50.00 10 Net
68,00
Sliding jaws for AX-Press
ROTEX VA pipe 12 mm.
RO 12 1 Set 19 51 50.00 09 Net
56,00
Battery 14.4 V, 3.2 Ah Li-Ion 1 19 51 74 Net
152,00
Tool set VA-Manuell
Complete set of tools for manual expansion of the ROTEX VA
pipes and for screwing on the sliding sleeves. With expanding
heads and sliding jaws for dia. 12, 16, 20, 25, 32 mm.
WSM 19 51 54 Net
818,00
Manual bending device
Practical manual bending device
for dimensionally accurate bending of
ROTEX VA pipes VA12, 16, 20, 25.
HGB 1 19 51 51 Net
154,00
Pipe cutting pliers
For right-angle and burr-free cuting to length
of ROTEX VA pipes 12 32 mm.
ROS 1 19 51 52 Net
58,50
Combined pipe cutter and
stripping pliers with calibrating mandrel
For VA, DUO and AL heating pipes
12 20 mm.
RAZ 1 1 17 11 10 Net
108,50
VA Installation system
149
Installation system
149
150
F
u
e
l

O
i
l

t
a
n
k
s
Fuel oil tanks
Fuel oil tanks
ROTEX variosafe the safe way to store heating oil
- Double-walled safety tanks for safe storage of heatlng oll
- |nstallatlon wlthout extra plasterlng and ollproof palnt
- Odour-blocklng by T|TLC, tested odour blocklng PPOOPLD 8APP|LP
- |nner and outer tanks can be separated
- l5 years warranty
- Peady for 8lo-Oll. Prepared for the use of
Heating oil with biogenic constituents
151
F
u
e
l

O
i
l

t
a
n
k
s
Installation regulations
Required room size (dimensions in cm)
Battery
Distance from ceiling
smaller than 60 cm
Battery
Distance from ceiling
smaller than 60 cm
VSF 3 / 603
VSF 4 / 604
VSF 5 / 605
VSF 6 / 606
VSF 8 / 608
VSF 13 / 613
VSF 18 / 618
209 x 244
295 x 244
381 x 244
467 x 244
244 x 295
244 x 381
244 x 467
VSF 103
VSF 104
VSF 105
VSF 106
VSF 108
VSF 113
VSF 118
244 x 247
244 x 351
244 x 455
244 x 559
295 x 282
381 x 282
467 x 282
Installation versions Wall distance Distance from ceiling
Single-row
battery
on one end side 40 cm,
other sides 5 cm
No regulations
Two-row
battery
Version A:
at each end and longitudinal side 40 cm,
on other sides 5 cm
60 cm
Version B:
on three sides 40 cm,
on fourth side 5 cm
No regulations
Variosafe installation regulations for the Federal Republic of Germany
Building regulations (German State Fire Codes) permit the storage of up to 5 000 litres of
heating oil in the installation room. It must be ensured that there is a minimum distance
between the boiler and the safety tank of 1 m if no radiation protection is available.
The plastic lining of the ROTEX A1 condensing oil boiler acts as radiation protection and
does not get any hotter than 40 C at any point. This has been certified by a TV report.
This confirms that a minimum gap of 10 cm between the oil tank and the A1 boiler is
sufficient. For handling purposes, we recommend a distance of at least 40 cm.
Fuel oil tanks
151
152
F
u
e
l

O
i
l

t
a
n
k
s
Heating oil tanks variosafe 1000 / 750 / 600 / 1500
1
0
0
0

l
i
t
r
e
s
Content / battery designation 1,000 l VSF 101 2,000 l VSF 102 4,000 l VSF 103 6,000 l VSF 104 8,000 l VSF 105
Accessory sets per
tank combination
1xANK 1xANK / 1xB2 1xANK / 2xB2 / 2xC / 1xD 1xANK / 3xB2 / 3xC / 2xD 1xANK / 4xB2 / 4xC / 3xD
Battery dimensions in cm 78 x 98 164 x 98 164 x 202 164 x 306 164 x 410
Room measurements in cm 88 x 143 174 x 143 209 x 247 209 x 351 209 x 455
Price per tank battery 804,00 1.502,00 3.066,00 4.546,00 6.026,00
1 tank 2 tanks 4 tanks 6 tanks 8 tanks
1
5
0
0

l
i
t
r
e
s
Content / battery designation 1,500 l VSF 151 3,000 l VSF 152 4,500 l VSF 153 6,000 l VSF 154 7,500 l VSF 155
Accessory sets per
tank combination
1xANK 1xANK / 1xB2 1xANK / 2xB2 1xANK / 3xB2 1xANK / 4xB2
Battery dimensions in cm 134 x 78 134 x 164 134 x 250 134 x 336 134 x 422
Room measurements in cm 179 x 88 179 x 174 179 x 260 179 x 346 179 x 432
Price per tank battery 1.084,00 2.062,00 3.040,00 4.018,00 4.996,00
1 tank 2 tanks 3 tanks 4 tanks 5 tanks
1
0
0
0

l
i
t
r
e
s
Content / battery designation 5,000 l VSF 117 10,000 l VSF 118 3,000 l VSF 122 4,000 l VSF 123
Accessory sets per
tank combination
1xANK / 4xB2 1xANK / 8xB2 / 2xC / 1xD 1xANK / 1xC / 1xD / 1xL2 1xANK / 1xB2 / 1C / 1xD / 1xL2
Battery dimensions in cm 422 x 98 422 x 202 164 x 202 250 x 202
Room measurements in cm 432 x 143 467 x 247 209 x 247 295 x 247
Price per tank battery 3.596,00 7.254,00 2.313,45 3.011,45
5 tanks 10 tanks 3 tanks 4 tanks
7
5
0

l
i
t
r
e
s
Content / battery designation 750 l VSF 1 1,500 l VSF 2 3,000 l VSF 3 4,500 l VSF 4 6,000 l VSF 5
Accessory sets per
tank combination
1xANK 1xANK / 1xB2 1xANK / 3xB2 / 2xC 1xANK / 5xB2 / 3xC 1xANK / 7xB2 / 4xC
Battery dimensions in cm 78 x 78 78 x 164 164 x 164 250 x 164 336 x 164
Room measurements in cm 88 x 123 174 x 209 209 x 209 295 x 209 381 x 209
Price per tank battery 684,00 1.262,00 2.586,00 3.826,00 5.066,00
7
5
0

l
i
t
r
e
s
Content / battery designation 3,750 l VSF 17 7,500 l VSF 18 2,250 l VSF 22 3,000 l VSF 23 3,750 l VSF 24
Accessory sets per
tank combination
1xANK / 4xB2 1xANK / 9xB2 / 2xC 1xANK / 1xB2 / 1xC / 1xL2 1xANK / 3xB2 / 2xC / 1xL2 1xANK / 3xB2 / 2xC / 1xL2
Battery dimensions in cm 78 x 422 164 x 422 78 x 164 / 164 250 x 164 250 x 250
Room measurements in cm 123 x 432 209 x 467 78 x 209 / 209 295 x 209 295 x 295
Price per tank battery 2.996,00 6.054,00 1.953,45 2.531,45 3.193,45
6
0
0

l
i
t
r
e
s
Content / battery designation 600 l VSF 601 1,200 l VSF 602 2,400 l VSF 603 3,600 l VSF 604 4,800 l VSF 605
Price per tank battery 644,00 1.182,00 2.426,00 3.586,00 4.746,00
Accessory sets, battery and
room measurements as 750 l
1 tank 2 tanks 4 tanks 6 tanks 8 tanks
6
0
0

l
i
t
r
e
s
Content / battery designation 3,000 l VSF 617 6,000 l VSF 618 1,800 l VSF 622 2,400 l VSF 623 3,000 l VSF 624
Price per tank battery 2.796,00 5.654,00 1.833,45 2.371,45 2.993,45
Sets of accessories, battery
and room dimensions
as for 750 l
5 tanks 10 tanks 3 tanks 4 tanks 5 tanks
153
F
u
e
l

O
i
l

t
a
n
k
s
Heating oil tanks variosafe 1000 / 750 / 600 / 1500
10,000 l VSF 106 3,000 l VSF 107 6,000 l VSF 108 4,000 l VSF 112 8,000 l VSF 113
1xANK / 5xB2 / 5xC / 4xD 1xANK / 2xB2 1xANK / 4xB2 / 2xC / 1xD 1xANK / 3xB2 1xANK / 6xB2 / 2xC / 1xD
164 x 514 250 x 98 250 x 202 336 x 98 336 x 202
209 x 559 260 x 143 295 x 247 346 x 143 381 x 247
7.506,00 2.200,00 4.462,00 2.898,00 5.858,00
10 tank 3 tanks 6 tanks 4 tanks 8 tanks
5,000 l VSF 124 6,000 l VSF 125
1xANK / 1xB2 / 2xC / 2xD / 1xL2 1xANK / 2xB2 / 2xC / 2xD / 1xL2
250 x 306 336 x 306
295 x 351 381 x 351
3.793,45 4.491,45
5 tanks 6 tanks
7,500 l VSF 6 2,250 l VSF 7 4,500 l VSF 8 3,000 l VSF 12 6,000 l VSF 13
1xANK / 9xB2 / 5xC 1xANK / 2xB2 1xANK / 5xB2 / 2xC 1xANK / 3xB2 1xANK / 7xB2 / 2xC
422 x 164 78 x 250 164 x 250 78 x 336 164 x 336
467 x 209 123 x 260 209 x 295 123 x 346 209 x 381
6.306,00 1.840,00 3.742,00 2.418,00 4.898,00
4,500 l VSF 25
1xANK / 4xB2 / 2xC / 1xL2
336 x 250
381 x 295
3.771,45
6,000 l VSF 606 1,800 l VSF 607 3,600 l VSF 608 2,400 l VSF 612 4,800 l VSF 613
5.906,00 1.720,00 3.502,00 2.258,00 4.578,00
10 tanks 3 tanks 6 tanks 4 tanks 8 tanks
3,600 l VSF 625
3.531,45
6 tanks
153
154
F
u
e
l

O
i
l

t
a
n
k
s
Heating oil tanks variosafe 1000 / 750 / 600
1
0
0
0

l
i
t
r
e
s
Content / battery designation 1 000 l WSF1001 2000 l WSF1002 3000 l WSF1003 4000 l WSF1004 5000 l WSF1005
Accessory sets per
tank combination
1xWA 1x WA / 1x WB 1x WA / 2x WB 1x WA / 3x WB 1x WA / 4x WB
Battery dimensions in cm 78 x 98 164 x 98 250 x 98 336x 98 422 x 98
Room measurements in cm 120 x 143 209 x 143 295 x 143 381 x 143 467 x 143
Price per tank battery 854,00 1.863,00 2.872,00 3.881,00 4.890,00
1 tank 2 tanks 3 tanks 4 tanks 5 tanks
6
0
0

l
i
t
r
e
s
Content / battery designation 600 l WSF601 1200 l WSF602 1800 l WSF603 2400 l WSF604 3000 l WSF605
Accessory sets per
tank combination
1x WA 1x WA / 1x WB 1x WA / 2x WB 1x WA / 3x WB 1x WA / 4x WB
Battery dimensions in cm 78 x 78 78 x 164 78 x 250 78 x 336 78 x 422
Room measurements in cm 123 x 123 123 x 209 123 x 295 123 x 381 123 x 467
Price per tank battery 694,00 1.543,00 2.392,00 3.241,00 4.090,00
1 tank 2 tanks 3 tanks 4 tanks 5 tanks
7
5
0

l
i
t
r
e
s
Content / battery designation 750 l WSF751 1500 l WSF752 2250 l WSF753 3000 l WSF754 3750 l WSF755
Accessory sets per
tank combination
1x WA 1x WA / 1x WB 1x WA / 2x WB 1x WA / 3x WB 1x WA / 4x WB
Battery dimensions in cm 78 x 78 78 x 164 78 x 250 78 x 336 78 x 422
Room measurements in cm 123 x 123 123 x 209 123 x 295 123 x 381 123 x 467
Price per tank battery 734,00 1.623,00 2.512,00 3.401,00 4.290,00
ROTEX variosafe, equipped with watersafe,
Safe heating oil tanks for high flood-risk areas
155
F
u
e
l

O
i
l

t
a
n
k
s
ROTEX variosafe
ROTEX variosafe douple wall safety tank wit TITEC fire protection and oil odour barrier.
Tested odour blocking PROOFED BARRIER. including integrated collection trough.
For installation without walling-off and oil-resistant paint.
Total storage capacity 600 l 25000 l Important:
With ROTEX variosafe 600, 750, 1.000, 1500 only use accessories ANK, B2, C, D, L2.
Article Comments Type Order No. Price
Variosafe 600 l
78 x 78 x 139 cm
Walling-off and
oil-resistant paint
not required
VSF 600 11 60 60 449,00
Variosafe 750 l
78 x 78 x 168 cm
Walling-off and
oil-resistant paint
not required
VSF 750 11 60 75 489,00
Variosafe 1,000 l
78 x 98 x 196 cm
Walling-off and
oil-resistant paint
not required
VSF 1000 11 61 00 609,00
Variosafe 1,500 l
78 x 134 x 196 cm
Walling-off and
oil-resistant paint
not required
VSF 1500 11 61 50 889,00
Basic kit ANK
Removal fitting for variosafe, GWG
LORO-X-connection sleeves, closing-off caps,
Installation spanner, with contents indicator
For variosafe
VSF 600 / 750 /
1000 / 1500
ANK 11 01 15 195,00
Connection packs B2
Connection pipes (TITEC),
Union nuts, o-rings
VSF 600 / 750 /
1000 / 1500
B2 11 02 03 89,00
Terminal pack C
End pipes (TITEC) cross-piece, union nuts,
Sealing caps, O-rings
VSF 600 / 750 /
1000
C 11 03 03 84,00
Fuel oil tanks
155
156
F
u
e
l

O
i
l

t
a
n
k
s
Fuel oil tanks
Article Comments Type Order No. Price
Connection kit D Only for tank
VSF 1000
D 11 08 01 88,60
Connection kit L2
End pipes (TITEC),
Connection pipe (TITEC),
Cross-piece, sealing caps,
T-pieces, O-rings
For the tanks
VSF 600 / 750 /
1000
L2 11 06 02 118,45
Assembly wrench For filling and
removal pipes
MOS 11 05 20 5,40
Manual pump
Household kit with reduction pieces
2 x 1
1
2 and M 60 x 4 to 1
1
2
and sealing plugs
HST 11 05 01 107,00
ROTEX watersafe
Safety fitting basic pack
Contents: Removal fitting and connection parts
for the individual tank
For variosafe
VSF 600 / 750 /
1000
WA 11 01 18 245,00
ROTEX watersafe
Safety fitting extension pack
Contents: Removal fitting, connection line and
connection parts for the extension tank
For variosafe
VSF 600 / 750 /
1000
WB 11 01 19 400,00
Watersafe distributor
For reducing suction resistance
For connecting up to 5 tanks in parallel
incl. coupling connections and bracket.
Required above 3 tanks.
For variosafe
VSF 600 / 750 /
1000
VWS 11 01 20 840,00
Content measuring set VSF For variosafe 11 05 06 17,00
Level indicator For variosystem
and highcube
11 05 03 27,00
Article Type Packaging
Unit
Ordering
No.
Price
per item
Price
per pack. unit
VA-Oil feeding line
PEX-AL compound pipe as oil supply line approved by the building supervision authorities in the DIBT test.
Test mark of the building supervision authority: Z-40.23-331
Thick-walled PEX inner pipe with butt-welded aluminium covering and silver-grey PE external layer.
Due to the aluminium covering 100 % diffusion tightness. Neutral to heating oil, prevents
no degradation. Type of delivery: ring coil packaged in box
VA-Oil pipe, 12 x 3 60 m 17 06 31 2,35 / m 141,25
Connection screwed fitting VA-Oil
For connection of the oil feed pipe VA-oil to the extraction armature and to the oil filter.
Clamping ring screwed fitting made of brass or parts in contact with oil made of stainless steel. Suitable for VA
oil pipe, 12 x 3,
Connection thread 3 / 8 male thread. Construction Control Test Sticker: Z-40.23-331
Connection screwed fitting VA-Oil VAR1 10 pieces. 17 80 13 10,15 / Each 101,45
Connect VA-Oil
10 m PEX-AL compound pipe as an oil-feeding
pipe with two screw connections
12 x 3 -
3
/ 8 male thread
10 m 17 06 32 55,00
ROTEX variosafe
157
F
u
e
l

O
i
l

t
a
n
k
s
Fuel oil tanks
Single-wall tanks
only for replacement
Article Comments Type Order No. Price
Variosystem 600 l
72 x 72 x 138 cm
Walling-off and oil-
resistant paint not
required
VS 600 11 06 00 291,20
Variosystem 750 l
72 x 72 x 165 cm
Walling-off and oil-
resistant paint not
required
VS 750 11 07 50 369,20
Variosystem 1,000 l
78 x 78 x 195 cm
Walling-off and oil-
resistant paint not
required
VS 1000 11 10 00 478,40
ROTEX highcube with TITEC against oil odour. Tested odour blocking PROOFED BARRIER. Single tank element (complete with T-pieces)
Highcube 1,500 l
78 x 120 x 190 cm
Walling-off and oil-
resistant paint not
required
HC 1500 11 15 00 655,00
Highcube 2000 l
78 x 160 x 190 cm
Walling-off and oil-
resistant paint not
required
HC 2000 11 20 00 868,40
Basic kit A
Extraction fitting for variosystem and
highcube, GWG LORO-X connection sleeves,
sealing caps, installation spanner
For the tanks
VS 600 / 750 / 1000
and HC 1500 / 2000
A 11 01 02 200,00
Connection packs B1 + B2
Connection pipes (TITEC),
Union nuts, o-rings
For the tanks
VS 600 / 750
For the tanks
VS 1000
and HC 1500 / 2000
B1
B2
11 02 02
11 02 03
85,00
89,00
Terminal pack C
End pipes (TITEC) cross-piece, union nuts,
sealing caps, O-rings
For the tanks
VS 600 / 750 / 1000
C 11 03 03 84,00
Connection pack L1 + L2
End pipes (TITEC) cross-piece, sealing caps,
T-pieces, O-rings
For the tanks
VS 600 / 750
For the tank
1000
L1
L2
11 06 01
11 06 02
120,55
118,45
Important information on state-of-the-art oil heating systems.
Single-walled PE / PA plastic tanks for heating oil storage are only
intended for replacement requirements. For new equipment and
modernisation, the Arbeitskreis Kunststoff-Batterietanks in the
Bundesverband Lagerbehlter e.V. recommends double-walled safety
tanks. Please contact your specialist for heating equipment for further
details.
Federal Association of Storage Contractors e.V.
Arbeitskreis Kunststoff-Batterietanks
www.behaelterverband.de
Our dealers often no longer have these tanks on stock.
In this case, you must anticipate delivery periods.
For new systems we recommend you, to fall back to our double wall
safety tank. Experience shows that there are often complaints due to
own constructions of collection spaces.
ROTEX variosystem with TITEC against the odour of oil.
Tested odour blocking PROOFED BARRIER. Single tank element
(complete with T-piece).
157
158
F
u
e
l

o
i
l

t
a
n
k
s

Article Type Order No. Price
ROTEX variocistern A 750
Basic tank element
with supply DN 50 and overflow DN 100
750 l 19 07 50 320,00
ROTEX variocistern B 750
Extension storage tank with connection set
(With KTW approval, price on application)
750 l 19 07 51 275,00
ROTEX variocistern A 1000
Basic tank element
with supply DN 50 and overflow DN 100
1,000 l 19 10 00 410,00
ROTEX variocistern B 1000
Extension storage tank with connection set
(With KTW approval, price on application)
1,000 l 19 10 01 365,00
Pump connection kit
Including suction hose, crossing
piece and float switch.
as dry running protection.
Cable length 5 m
PAS 19 30 00 110,00
Replenishment set
For fresh water.
Including float switch, solenoid valve and inlet
funnel.
Cable length 5 m.
NSF 19 30 10 185,00
Connection kit variocistern VBS 19 30 40 20,00
Level indicator
Fits filling opening
EK 50 display in cm
IDEAL-S 19 30 20 30,00
Rainwater collector plastic version
From DN 70 DN 100 with fine sieve, mesh 0.1
mm, side-connection 50 mm
RWS-PP 19 30 38 120,00
Fuel oil tanks
Rainwater storage tanks
159
General Business Terms
I. General points
1. These General Business Terms apply to all offers, delivery contracts and other services provided
by us, including future offers, delivery contracts and services.
2. Any purchasing or business terms of the buyer which may be in contradiction of these General
Business Terms will only apply in as far as they are recognised in writing by our management; it is
insufficient to have a written recognition by our field service staff.
3. All agreements must be set down in wiritng. This applies to secondary agreements and
undertakings as well as to subsequent amendments to the contract.
4. Rights and obligations of the buyer arising from this contract may not be transferred to third
parties without our written approval.
5. Should any of the stipulations of this contract be or become invalid in law, this does not affect
the validity of the remaining stipulations of the contract.
6. These General Business Terms are only valid in dealings with merchants, legal entities under
public law and special funds under public law. At the latest, our General Business Terms are
considered to take exclusive effect as of receipt of goods or services.
II Offers, prices, transfer of risk
1. Our offers are subject to change and only become valid with our written
order acknowledgement.
2. Information given in descriptions relating to the appearance, performance, weights,
dimensions, drawings, consumption of operating materials, operating costs of the object of
purchase and which is valid on closure of the contract is to be considered as non-binding and
approximate; in addition, they require optimum operating conditions. This does not apply to
characteristics of the object of purchase which are expressly guaranteed by us in writing. In as far
as characters or numbers are used to designate the order or the object of purchase, this does not in
itself impart any rights. We reserve the rights of title and copyright to price quotations, drawings
and other documentation; they must not be made available to third parties.
3. Unless otherwise stipulated, the price of the object of purchase is to be understood ex works
excluding VAT at the rate applicable on the date of invoicing. Packaging and delivery costs and
any additional services (e. g. acceptances, conveyances etc.) rendered by us at the customer`s
request and which do not constitute part of the services to be rendered by us as defined in the
written contract or our order acknowledgement will be invoiced separately. The prices quoted
for confirmed orders cannot be reduced as a result of the customer placing follow-up orders. If
the delivery date agreed upon for the merchandise ordered from us is more than four months
after the closing of the contract, we reserve the right-to pass on to the customer in the form of an
appropriate price increase any increase in our costs as the result of price increases made by our
suppliers or other price increases.
4. Unless otherwise stipulated in the order acknowledgement, delivery is "ex works", i.e. at
Gglingen or one of our suppliers' warehouses. Should the purchaser request it, we can cover the
delivery with transport insurance; the costs incurred will be borne by the purchaser.
5. We dispatch all merchandise for the customer's account and risk. If, as the result of a special
agreement, delivery is made freight-free, unloading is to be effected by the customer. If
the merchandise is dispatched to the customer at his request, the risk of accidental loss and
deterioration of the goods passes to the customer with delivery of the merchandise by us to the
carrier, at the latest when the goods leave our works or the warehouse, irrespective of whether
the goods are dispatched from the place of fulfilment or who bears the freight costs. If the goods
are ready for dispatch but dispatch or acceptance of the goods is delayed for reasons beyond our
control, the transfer of risk to the customer is considered to be accomplished when the latter
receives confirmation that the goods are ready for delivery.
6. Partial deliveries are permissible. With partial deliveries the risk transfers to the purchaser as
per subparagraph 5.
III. Payment and delay in payment
1. Unless otherwise stipulated in the order acknowledgement, payment of the purchase price
and of any additional services falls due on receipt of the invoice. The buyer will be considered to
be in arrears of payment at the latest 30 days after receipt of the invoice. This does not affect the
seller`s statutory right to issue a reminder to the effect that the buyer is in arrears.
2. In the case of an agreed date of payment or an agreement on partial payments, the entire
sum, independent of the due dates of any bills of exchange, falls due immediately should any
reasonable doubt arise as to the buyer`s ability to fulfil his financial obligations, in particular if
the customer is more than 14 days in arrears with an instalment, if he suspends payments or if
bankruptcy or composition proceedings are initiated against him.
3. Payment instructions, cheques and bills of exchange will only be accepted in payment by
special agreement; all collection and discounting costs to be borne by the buyer.
4. The purchaser can only offset against our claims if the counter-claim of the purchaser is
uncontested or if there is a legal title involved; retention rights can onlt be implemented only
insofar as it refers to claims arising from the purchasing contract.
5. If payment in instalments has been agreed upon and the buyer is in arrears of payment of two
successive instalments, we are entitled, after setting an appropriate deadline for payment, to
withdraw from the contract or claim damages for non-fulfilment of the contract, while retaining
our rights as defined in Section VI, item 5.
6. Interest on arrears will be charged at a rate of 8 %p.a. above the currently valid basic interest
rate. This interest will be charged at a higher or lower rate in the event that we can produce
verification of paying a higher interest rate or the buyer of a lower interest rate.
IV. Delivery, delay in delivery and delay in acceptance
1. Unless otherwise agreed in writing, delivery dates and delivery periods stipulated by us
are without obligation. Delivery dates named by us, even where agreed upon formally, are
subject to our receiving complete and correct delivery from our suppliers, unless we ourselves
are responsible for the failure to deliver correctly or punctually; the right to partial deliveries is
reserved. The delivery period begins with the date of posting of our order acknowledgement, but
not before the buyer has provided all necessary documentation, permits and releases and not
before receipt of any deposit or initial payment agreed upon. The delivery period is considered as
met if the goods in question have left our works or the customer has been notified that the goods
are ready for delivery before expiry of the delivery period.
2. Furthermore, the delivery period will not be deemed to begin before all technical and
commercial details with regard to the processing of the order have been clarified.
3. If we fail to deliver punctually for reasons for which we can be held legally responsible, the
buyer is entitled to claim damages from us for costs which he is proven to have incurred, to the
max. amount per calendar week of 1%of the value of that part of the delivery which could not
be put into operation due to delays in production of objects forming part of the delivery, such
damages being limited to a maximum of 5 %of the value of that part of the delivery which could
not be put to the intended use.
4. The buyer's right to withdraw from the contract because of late delivery or to claim damages
for non-fulfilment of our contractual obligations can only be exercised after the expiry of an
appropriate extension of the delivery period, to be granted by the buyer after our failure to deliver
within the fixed period; a reasonable extension period is considered to be up to 60 days. Under
no circumstances will we pay damages above and beyond the value of losses which can typically
be expected in the case in question. The buyer's claim to damages is limited to 20%of the value
of the delivery, unless the delay in delivery was caused by gross negligence on the part of our
staff or management.
5. Under no circumstances will we pay damages above and beyond the value of losses which can
typically be expected in the case in question.
6. The fulfilment of the obligation to deliver entered into by us is only possible if the buyer also
fulfils his obligations correctly and punctually. We reserve the right to suspend work on the order
or to refuse to deliver the goods, despite acceptance being provided, if we have reasonable doubt
as to the buyer's ability to fulfil his financial obligations. In this case, we are entitled to make
continuation of work on this order or the delivery of the goods ordered dependent on the buyer
providing suitable securities to cover our claim.
7. In the event of acts of God or disruptions in production at our company or that of our suppliers,
for example as a result of unrest, strikes or lockouts, and due to which we are temporarily and
through no fault of our own prevented from delivering the goods on the date or within the
period agreed upon, the periods and deadlines stipulated in the contract will be extended by the
duration of the disruptions caused by these aforementioned circumstances. The customer will be
duly notified of any such circumstances.
8. Should the reasons named under subparagraph 7 render delivery impossible, we are absolved
of our obligation to deliver and the customer is not entitled to file for damages or non-fulfilment
of the contract against us.
9. If delivery is delayed as a result of culpable action by the buyer or for reasons for which the
buyer can be held responsible, the latter bears the costs incurred as a result of the delay (such as
storage costs etc.).
10. The manufacturer reserves the right to make alterations in the design, form, colour and range
of delivery during the delivery period, providing that the goods are not changed significantly
and the alterations are such as the buyer can be reasonably expected to accept. This does not
apply in cases where we have expressly guaranteed in writing to deliver merchandise of a specific
characteristic.
11. If the purchaser places orders based on particular measurement units (m
2
/ m) and if,
because of our pack sizes, we are only able to make a delivery by sending out slightly more of the
purchased material, the purchaser is obligated to pay for this slight increase in quantity resulting
from the pack sizes. A slightly greater quantity is defined as a delivery of up to 20%more than
ordered. In the event of it only being possible to process the order by delivering more than 20%
above the quantity ordered, we will notify the purchaser / customer accordingly.
V. Acceptance
1. The buyer is entitled to inspect the goods at the agreed place of acceptance within 8 days of
receiving notification that the goods are ready for delivery, and is obliged to accept the goods
within this period.
2. Should the purchaser not fulfil their acceptance obligations quoted in subparagraph 1, the
purchased goods will be considered to be accepted in the terms of the contract after the expiry of
the 8th day after issuing the readiness notice; this is stated explicitly in the notice of readiness.
3. If the buyer fails to fulfil his obligations, in particular his obligation to provide acceptance and
take delivery of the goods, despite having been granted an appropriate extension by us in which
to do so, or if the buyer refuses definitely and finally to accept or take delivery of the goods,
or if the buyer is obviously not in a position to effect payment for the goods, we are entitled
to withdraw from the contract or to claim damages for non-fulfilment of the contract. We are
entitled to claim damages amounting to 15 %of the purchase price. The amount claimed may be
higher if we can document that the losses incurred were more considerable or lower if the buyer
can prove that the losses incurred were lower.
4. In the event of us filing a claim for damages, we will claim 15%of the purchase price, unless
higher losses have been incurred and can be documented, in particular in view of the high cost
of redemption of the merchandise. This applies unless the customer can prove that the losses
incurred by us were lower. In the event of a claim for damages, no extension need be granted if
indications that the customer is unable to fulfil his financial obligations have appeared after the
signing of the contract, for example if the customer is in arrears or has suspended payment, has
filed for bankruptcy, in the event of security transfer of floating capital or if unfavourable reports
are received from banks, credit institutions or credit insurance companies.
VI Retention of title
1.We retain the right of title to merchandise delivered by us until all our claims have been
settled, irrespective of the legal reason, until all checks or bills of exchange accepted in payment
have been honoured, even if the purchase price for specifically named items has been paid. In
the event of open accounts, the goods to which we retain the title serve as a security for our
accounts receivable. In particular, we retain right of title to the goods, until, for example, the
buyer has released us from obligations incurred on his behalf with regard to endorsements of
bills of exchange. We also retain the title to the merchandise for all claims subsequently arising
against the buyer, for example for repairs, spare parts deliveries or arising from the ongoing
business relationship.
2. The buyer is under obligation to maintain the goods in good order during the period in
which we retain title, to have all required servicing and maintenance work prescribed by the
manufacturer effected immediately, with the exception of emergencies, by us or by a repair and
maintenance facility approved by the manufacturer.
3. The buyer is under obligation to insure the goods adequately and at his own cost against fire,
water and theft at replaceable value.
4. While we retain title to the goods, the buyer is entitled to hold and to make use of the said
goods, provided that he fulfils his obligations as defined in this section and is not in arrears of
payment. If the buyer is in arrears or fails to fulfil his obligations with regard to the retention
of title, we are entitled to demand that the object of purchase is surrendered to us; the latter is
obliged to hand over the object of purchase without delay and without any right of retention,
unless such right arises form the purchase contract. If we have repossessed the goods from the
buyer, we can, after giving appropriate notice sell the goods on the free market for the best
possible price, which will then be deducted from the purchase price owed to us. All costs for
redemption and liquidation of the goods to be borne by the buyer. The liquidation costs, without
verification, are 10 %of the liquidation yield, including VAT. They are to be assessed higher or
lower if we can provide evidence of higher costs or if the purchaser can verify lower costs. The
proceeds of the sale will be credited against the buyer's obligations after deduction of the costs
and other claims in connection with the purchase contract.
5. The purchaser is entitled to re-sell the purchased goods in a proper sales procedure; he is not
entitled to a pledge or assignment as security. The buyer is under obligation to secure our rights
on credit when reselling goods to which we retain right of title. However, the buyer assigns to
us in advance all claims to the amount of the total sum of the invoice (incl. VAT) for resale to his
customers or third parties, irrespective of whether the goods are sold before or after processing.
We accept this assignment. The buyer retains the right to collect the amount even after
assignment of the rights. This does not affect our right to collect the amount ourselves. However,
we undertake not to collect the amount as long as the buyer continues to fulfil his obligations
with regard to the proceeds of the sale, is not in arrears and in particular, as long as he has not
filed for bankruptcy or composition or has suspended payment. If this is the case, however, we can
demand that the buyer informs us of the claims he has assigned and supplies the names of the
debtors and all other necessary information, hands over the necessary documents and informs his
debtors (third parties) that he has assigned his rights to the claims in question.
6. Where third parties have regress to the goods, in particular in the case of garnishment of
the goods or of a workshop exercising its right to foreclosure, the buyer is obliged to notify us
immediately in writing and to inform the third party immediately of our retention of title. The
buyer bears all costs for incurred for reversing the procedure and recovering the goods in as far as
they are not forfeit to third parties.
7. Processing or alteration of the goods by the buyer is always effected to our benefit, without
incurment of any liability on our part in this connection. If the goods are processed with other
objects not owned by us, we acquire part-ownership of the new object, to an extent depending
on the value of the goods to which we retain the title relative to the other procesed objects at the
time of processing. The same applies to the object arising from the processing as for the object of
purchase to which we retain the title.
8. We undertake to release the securities to which we are entitled at the request of the buyer in as
far as the value of the securities pledged exceeds our claim by more than 20%.
9. If the buyer sells the goods subject to retention of title or the joint property transferred to us
in accordance with subparagraph 7, he will then relinquish the claim to the level of the invoice
end-value (including VAT) on the buyer with all ancillary rights to the value of the secured claim
to us for safety reasons.
10. The buyer will notify us immediately of any foreclosure by third parties with regard to assigned
claims, will provide all information necessary in order to avoid such measures and will make all
relevant documents accessible.
VII Returns
1. Goods returns are fundamentally excluded.
2. Should we accept a return, as an exception, we retain the right to issue a lump-sum invoice
to cover the costs incurred (checking, re-stocking etc.) to the level of at least 20 %of the net
sales price.
VIII Warranty
1. In the event of justified claims by the buyer under the terms of warranty, we will either remedy
the fault by making repairsor supply a fault-free replacement for the faulty item, as we see fit.
Where we supply a fault-free replacement for a faulty item, the buyer is obliged to return the
faulty item to us.
2. We retain the right to refuse to provide a replacement for faulty goods where this would only
be possible at unreasonably high cost. When considering whether to effect repairs or provide
a replacement, particular considerations are the value of the object in fault-free condition,
the extent of the fault and the question of whether repairs can be effected without significant
disadvantage to the buyer.
3. If we decide to effect repairs, it remains at our discrection whether these are carried out at our
place of business or that of the buyer. The buyer must consult us before repairing faults in the
goods or having such faults repaired.
4. When effecting repairs, we are entitled to repair all damage caused by the fault.
5. The buyer is not entitled to withdraw from the contract if the fault only constitutes a minor loss
in value or restriction in the serviceability of the goods.
6. Under the terms of the warranty, we are liable only for publicly declared consistency
characteristics / consistency statements. We assume no liability for statements made publicly by
third parties concerning the characteristics of the object of purchase, in particular in advertising or
rating of particular properties of the object.
7. We assume no liability if
1. the object of purchase has been handled incorrectly or subjected to unreasonable use, or
2. the purchased goods have been repaired, serviced or processed previously in a company not
authorised by us for support, or
3. if parts are fitted to the purchased goods, whose use has not been approved by us or if the
purchased goods have been modified in a way not approved by us, or
4. if the purchaser has not followed the regulations concerning the processing, maintenance
and care of the purchased goods (e.g. operating instructions), provided that it cannot be
excluded that one of these conditions as become the cause of the fault.
8. Natural wear and tear are excluded from the warranty.
9. The buyer is under obligation to inspect the object of purchase immedately and thoroughly
on receipt, where necessary to carry out random testing. Obvious defects must be reported to
us immediately in writing, at the latest 8 days after receipt of the object of purchase. Failure to
report such defects immediately will render claims under the warranty null and void. The object of
purchase must be stored appropriately and returned to us if expressly requested by us.
10. We advise our customers to the best of our knowledge and on the basis of our own insights,
but without any obligation. Any information, transfer and application or use of the object of
purchase is without obligation on our part unless otherwise expressly guaranteed in writing.
Information provided by us does not exempt the buyer from the obligation to verify information
for himself.
11. From the beginning, the buyer bears the full burden of proof with regard to any claims
made by him, in particular in connection with claims relating to faults existing at the moment
of transfer of risk.
12. Once processing or installation of the merchandise supplied has begun, notice of defect
can only be served if it can be proved that the fault was already present before processing or
installation of the merchandise suppied by us.
13. The maximum warranty period as per 438 section 1 No. 3 of the BGB (German Civil Code) is
one year from delivery of the merchandise.
14. In as far as delivery is effected in connection with the construction of a building,
( 438 section 1 No. 2b BGB), the warranty period is reduced to 4 years, in the case of work
performed on a plot to 2 years, where VOB (German Construction Contract Procedure) Part B
applies for the buyer with respect to his client.
15. In all other cases as per 438 section 1 No. 2 of the BGB, the maximum warranty period is
4years from delivery of the merchandise.
IX. General limitation of liability
1. Liability for material damage is excluded where such damage is to be attributed to minor
negligence with respect to a secondary obligation and where it does not constitute a threat to
the contractual use. This applies in particular where the damage caused is covered by insurance
taken out by the buyer.
2. Irrespective of the reason for the claim, our duty of replacement is limited to the extent of
damage to property and persons.
3. Except in cases of intentional damage, our liability is limited to such damage as can typically be
expected in ordinary business circumstances.
4. In as far as our liability is excluded or limited, this also applies to the personal liability of our
employees, workers, staff, representatives and vicarious agents.
5. The buyer's claims for indemnity fall under the statue of limitations after one year from delivery
of the merchandise. This does not apply in cases where we are accused of gross negligence or
where we are held responsible for physical injury or damage to health or in the event of the loss
of the life of the buyer.
6. The existing limitations of libility do not apply to claims from the product liability law
( 1, 4 Product Liability Law).
X. Special stipulations for orders executed from drawings,
models etc.
1. In as far as we deliver merchandise produced to our own drawings, samples and models,
these drawings, samples and models form the basis for technical execution of the merchandise.
However, we can assume no liability with regard to the intended use to which the merchanidse
is put.
2. We retain right of title to and copyright with regard to our drawings, samples and models.
Under no circumstances may such documentation be made accessible to third parties. Press
moulds and die-casting moulds remain our property.
3. The manufacturing costs are advanced by the customer / buyer and credited to him to the
amount of 5%of the value of the merchandise on the invoice for each running delivery until the
full sum has been amortised. We undertake to use the moulds exclusively for the purposes of
execution of the customer / buyer's order unless other use is expressly agreed upon.
4. Where we deliver merchandise produced to the customer's samples, drawings or models, the
customer is responsible for ensuring that we are not acting in violation of the property rights of
third parties. If we are prevented, by a third party, based on a copyright that belongs to him, from
manufacture and delivery of objects that are manufactured in accordance with drawings, models
or samples from the purchaser, we are entitled, without having to check the legal situation,
and with exclusion of all damages compensation claims by the purchaser / buyer, to cease
manufacture and delivery and to demand compensation of the costs incurred.
5. The buyer / customer will compensate us for any direct or indirect damage suffered as a result
of the violation of industrial property rights and the assertion of such industrial property rights.
In the event of legal proceedings, and on request, the buyer / customer will advance to us an
appropriate sum for settlement of litigation costs.
XI. Place of performance and venue
1. The law of the Federal Republic of Germany applies. The UN Sales Convention does not apply.
2. The sole place of performance for all our obligations to the buyer arising from the contract,
including warranty obligations, is the place of business of our company.
3. The sole legal venue for any disputes arising from this contract - including disputes with regard
to checques or bills of exchange - is the place of business of our company. This also applies where
the customer has no general legal venue in Germany or does not reside in Germany, whether
permanently or temporarily, at the time of instigating the proceedings.
159
160
Our Sales network in Europe
Australia
Inform Energy Pty Ltd.
Unit 5 / 60 Fairford Road
Padstow NSW 2211
Tel +61 / 2 9790 8479
Fax +61 / 2 9790 8495
E-Mail sales@informenergy.com.au
www.informenergy.com.au
Belgium
SANI-CV-IMPORT BVBA
Legen Heirweg 10
B-9890 Gavere
Tel +32 938 491 76
Fax +32 938 407 76
E-Mail info@rotex-heating.be
www.rotex-heating.be
Croatia
DAIKIN Airconditioning
Predstavnitvo u Republici Hrvatskoj
Budmanijeva 5/V
HR - 10000 Zagreb
Tel +385 /1/ 6065 850
Fax +385 / 1 33 25 065
E-Mail office@daikin.hr
Denmark
BKF-Klima A/S
Tempovej 18-22
2750 Ballerup
Tel +45 (0) 7026 5666
Fax +45 (0) 7026 0223
France
ROTEX Heating Systems SARL
1, rue des Artisans
F-68280 Sundhoffen
Tel +33 / 3 89 21 74 70
Fax +33 / 3 89 21 74 74
E-Mail info@rotex.fr
www.rotex.fr
Greece
Tempa S.A.
Technothermical Represent
Pefkon Street 126
Heraklio, GR-14122 Athens
Tel +30 / 210 284 48 88
Fax +30 / 210 281 64 39
E-Mail info@tempa.gr
www.tempa.gr
Japan
Tozai Trading
1-26-8 Higashiazabu Ic-Houme
Minato-Ku
J-106-0044 Tokyo
Tel +81 (33) 58 53 351
Fax +81 (33) 58 53 379
E-Mail s.nakagorne@tozaishoji.co.jp
Macedonia
DAIKIN Airconditioning Central
Europe HandelsgmbH
Campus 21, Europaring F12/402
A-2345 Brunn am Gebirge
Tel +43 22 36 / 3 25 57-0
E-Mail office@daikin.at
Malta
Klimaflo Air Conditioning
16, Triq il Hgejjeg
M - San Gwann SGN 3541
Tel 00356 270 111 18
Mobile +356 994 951 61
E-Mail roger@klimaflo.com
www.klimaflo.com
Poland
Daikin Airconditioning Poland Sp. z
o.o.
ul. Tamowa 7
02-677 Warszawa
Polska
Tel +48 22 319 90 00
Fax +48 22 433 51 98
E-Mail office@daikin.pl
www.daikin.pl
Romania
DAIKIN Airconditioning Central
Europe - Romnia, MD
Calea Floreasca 169A, Corp B, etaj 8
RO - 014459 Bucuresti
Tel +40/21/307 97 00
E-Mail office@daikin.ro
Slovenia
DAIKIN Airconditioning Central Europe
HandelsgmbH
Campus 21, Europaring F12/402
A-2345 Brunn am Gebirge
Tel +43 22 36 / 3 25 57-0
E-Mail office@daikin.at
Switzerland
Domotec AG, Haustechnik
Lindengutstrae 16
CH-4663 Aarburg
Tel +41 / 62 787 87 87
Fax +41 / 62 787 87 00
E-Mail info@domotecch
www.domotec.ch
Austria
DAIKIN Airconditioning Central
Europe HandelsgmbH
Campus 21, Europaring F12/402
A-2345 Brunn am Gebirge
Tel +43 22 36 / 3 25 57-0
E-Mail office@daikin.at
Bosnia and Herzegovina
DAIKIN Airconditioning Central
Europe HandelsgmbH
Campus 21, Europaring F12/402
A-2345 Brunn am Gebirge
Tel +43 22 36 / 3 25 57-0
E-Mail office@daikin.at
161
Our Sales network in Europe
Czech Republic
DAIKIN Airconditioning Central
Europe Czech Replublic
IBC Pobrczni 3
CZ 18600 Praha 8
Tel +420 221 715 700
Fax +420 221 715 701
E-Mail officevdaikin.cz
www.daikin.cz
Finland
Lmpnen Finland Oy
P.O. Box 35
90101 Oulu
Tel +35 (0) 20 785 785
E-Mail info@lamponen.fi
www.lamponen.fi
Great Britain
Daikin Airconditioning UK Ltd
The Heights Brooklands
Weybridge KT13 0NY
Tel +44 84 56 41 90 00
Fax +44 84 56 41 90 09
E-Mail heating@daikin.co.uk
www.altherma.co.uk
Italy
ROTEX il marchio della Divisione
Riscaldamento di DAIKIN AIR CONDI-
TIONING ITALY S.p.A.
Via Milano 6
I-20097 San Donato Milanese (MI)
Tel +39 02 51619.1
Fax +39 02 51619.222
E-Mail info@rotexitalia.it
www.rotexitalia.it
Numero verde ROTEX 800-886699
Lithuania
UAB Celsis
Verslo g.3
Kumpiu km
LT-54311 Kauno r.
Lithuania
Tel +370 37750824
Faks +370 37452728
E-Mail kaunas@celsis.lt
Malaysia
AUMADA Energy & Technologies (M)
Sdn Bhd
No. 10, Block D, Taipan Damansara
Jalan PJU 1A/3K, Ara Damansara
47301 Petaling Jaya
Selangor Darul Ehsan
Malaysia
Tel +603 7842 6778
Fax +603 7842 6737
E-Mail enquiry@aumadaworld.com
www.aumadaworld.com
Norway
SGP Varmeteknikk AS
Postboks 506
N-1301 Sandvika
Tel +47 / 67 52 21 21
Fax +47 / 67 67 52 21 31
E-Mail mail@sgpvarme.no
Portugal
Hiperclima
Central de Distribuicao
Termica de Portugal, S.A.
Zona Industrial dos Pousos
P-2411-901 Leiria
Tel +351 / 244 816600
Fax +351 / 244 816618
E-Mail geral@hiperclima.pt
www.hiperclima.pt
Slovakia
DAIKIN Airconditioning Central
Europe Slovakia
Galvaniho 15/C
SK 82104 Bratislava
Tel +421 (2)57 10 32 11
Fax +421 (2)57 10 32 99
E-Mail office@daikin.sk
www.daikin.sk
Spain
ROTEX Heating Systems S.L.U.
Mitger, Nau 2 P.I. La Masia
ES-08798 Sant Cugat Sesgarrigues
(Barcelona)
Tel +34 (93) 8 99 20 61
Fax +34 (93) 8 99 20 63
E-Mail info@rotex-heating.com
www.rotexspain.com
161
162
Notes
R
O
T
E
X

P
r
i
c
e
s

a
n
d

s
p
e
c
i
f
i
c
a
t
i
o
n
s

0
4
/
2
0
1
3

ROTEX Heating Systems GmbH
Langwiesenstrae 10
D-74363 Gglingen
Fon +49 (71 35) 103-0
Fax +49 (71 35) 103-200
E-Mail info@rotex.de
www. rotex.de


R
O
T
E
X


E
r
r
o
r
s

a
n
d

t
e
c
h
n
i
c
a
l

m
o
d
i
f
i
c
a
t
i
o
n
s

r
e
s
e
r
v
e
d


0
0
8
.
1
0
0
7
9
4
4


>
G
B
<


0
5
/
2
0
1
3

You might also like