STEAM LEAKAGE AT VARIOUS AREAS PULP MILL 1 150 PSI steam line trap valve near Digester No.

1 to be changed. 2 150 PSI steam line isolating valve body hole & gland leakage to be changed. 3 Dig. No.2,4 steam control valve gland & bonnet joint to be changed. 4 Dig.No.2,3,4 steam control valve gland leakage to be changed. 5 150 PSI steam trap valve leakage near caustic vat dilution Pump. 6 150 PSI steam line R T D & control valve outlet joint leakage. 7 49 PSI steam vent line valve inlet joint leakage ( Manual Valve). 8 490 PSI steam to doctoe (Old WP) valve gland leakage & gauge nipple leakage. 9 49 PSI steam to flow jet heater valve outlet joint & gland leakage. 10 Caustic mixer steam control valve bonnet joint , gland leakage & line hole to be welded. 11 ClO2 steam mixer inlet valve gland leakage. 12 Clo2 steam mixer line & nozzles to be changed.

POWER HOUSE 1 Header drain both sidee 2nd valve gland leakage. 2 850 PSI header safety valve not working. 3 Soot blower Rec. main isolating valve out of order to be changed. 4 Soot blower 1st service valve position to be changed for smooth operation of P.R.D.S valve. 5 850 PSI header common drain line bend consists of a big sized hole aboveM.W Booster Pump 6 Tissue Plant No.1 & Pilot Plant 2nd isolating valve flange after valve leakage above maintenance room door. 7 Tissue Plant No.2 desuperheating water control valve flange leakage & all valve including by pass line valve leakage needs to be changed. 8 Tissue Plant No. 2 desuperheating steam control valve flange & bend leakage to be attented. 9 850 PSI line for 150 PSI desuperheating main isolating valve gland leakage. 10 Paper machine Turbine steam valve, heating line valve heavy gland leakage. 11 Power Boiler No.1 steam line heating valve hand wheel missing & is in jam condition. 12 Recovery Boiler steam heating valve spindle damaged needs replacement. 13 850/150 PSI P.R.D.S main valve gland leakage near header 14 Transfer Pump main isolating valve gland leakage. 15 16 MW Turbine steam line heating valve , heavy gland leakage. 16 6 MW steam line drain valve hand wheel missing(1 Nos.) & two Nos. suffers heavy gland leakage. 17 Power Boiler No.2 water sample line 2nd valve hand wheel missing. 18 Digester House steam valve 150 PSI header, heavy gland leakage. 19 Valve gland leakage at 150 PSI header & 49 PSI header. 20 75 PSI drain header valve R.H.S gland leakege. 21 Desuperheating line of 150 PSI steam valve after control valve , heavy gland leakage. 22 Power Boiler No.2 gauge glass water line valve hand wheel missing. 23 850/150 PRDS & 16 MW extraction common line leakage at West side near welded line support. 24 49 PSI steam header drain valve at R.H.S to be changed due since it is in jammed condition. 25 49 PSI steam to Pulp Mill main valve bottom flange leakage. 26 Make up water line leakage at three places needs rectification. 27 Flash tank safety valve blow down line , both joint leakage from flange. 28 Pilot plant cond. Line leakage from flange joint near flash tank. 29 Tissue Plant No.2 steam line drain valve gland leakage. 30 Tissue Plant No.2 desuperheating line main isolating valve leakage to be attended. 31 Wander bleed line hole near valve to be rectified. 32 Stage Heater condensate line flange leakage below stage heater. 33 Desuperheating pp recirculation line consists leakage just above the Desuperheating pp.to be Heavy leakage at Feed water isolating valve of C.F.B.C Boiler near Transfer Pump No.1 34 rectified. 35 Power Boiler No.2 both superheater drain valve gland leakage to be rectified. 36 Paper Machine cond. Line consists leakage above MAC 4.

WATER LEAKAGE AT VARIOUS AREAS


PULP MILL 1 Warm water tank make up line hole to be welded. POWER HOUSE 1 Heavy leakage at Make up pump discharge line at three places. 2 Cation out let common line leakage from welded joint above decab control valve. 3 Discharge Pump No.3 discharge line joint leakage. 4 Polishing plant after pump discharge line between Mb 2 & 3. 5 Tissue plant No.1 & Pilot Plant water line isolating valve heavy gland leakage. 6 Cooling Water Pump No.1 Motor side gland leakage. 7 Cooling Water Pump No.2 NRV leakage. 8 Cooling Water Pump No.3 Motor side gland leakage. 9 Jockey Pump No.2 air release valve is not working resulting continuous water leakage. 10 Jockey Pump No.1 discharge valve heavy gland leakage to be rectified. 11 Make up Pump tank upper side damaged,hence there exists leakage after 4'5" water level. 12 Boiler Deashing line leakage near Blow Down tank.

You might also like