The TY370/GRP01 is used in safety critical applications where a delay is required between the opening of a control contact and the release of a normally energised slave relay. The slave relay is powered from the TY370/GRP01 and thus does not require a separate supply. The TY372 is used in applications where an operate delay longer than that achievable by slugging is required. STD S T S
R a i I
C a t a I o g u e
N u m b e r
S T S
R e f e r e n c e
( W e s t i n g h o u s e
R e f e r e n c e )
R a t e d
V o I t a g e
C o n t a c t s
P i n
C o d e
( P i n s )
S p e c i f i c a t i o n
TY372/GRP01 STD5 (QTD5) 50 V DC 5F 2B (B, D, F, H, X) N/A TY372/GRP02 STD5 (QTD5) 50 V DC 4F 3B (B, E, G, H, X) N/A TY370/GRP01 STD4 (QTD4) 12 V DC N/A (B, C, E, G & X) N/A N e t w o r k
R a i I
A c c e p t a n c e
N u m b e r
N/A N/A N/A STS RaiI ReIays.
Modular plug in design. Non weld contacts. Silver and carbon impregnated with silver contact tips. Proven reliability. Low life cycle cost. (FORMERLY FELD AND GRANT) 2010 - STS Rail Ltd Page 2 of 4 TY370/GRP01 & TY372/GRP01-02 SLOW RELEASE & OPERATE DELAY UNITS STD REAR VEW OF RELAY A D 1 Timing SIave VoIts 1 2 Timing SIave VoIts 2 3 Timing ControI Contact 3 4 4 5 Reset Contacts 5 6 6 7 Timing SIave VoIts 7 8 SIave VoIts 8 R1 SuppIy +ve SuppIy -ve R2 R3 SIave ReIay +ve SIave ReIay -ve R4 TY370/GRP01 Adjustment within each range is achieved by a potentiometer accessed through a hoIe in the cover which once adjusted is seaIed by a tamperproof IabeI
AIways check and if necessary readjust the timing when the reIay is repIaced.
EIectricaI Ieakage to terminaI A1, A2, A3 & A7 couId inhibit or Iengthen the time deIay. Strapping shouId be as short as practicaI and made using appro- priate signaIIing cabIe. EIectricaI Ieakage between terminaIs D3 and D4 or terminaIs D5 and D6 couId inhibit or Iengthen the time deIay. Strapping shouId be as short as practicaI and made using appropriate signaIIing cabIe.
The sIave reIay must be an approved appropriate BRB930 series signaIIing reIay. Time Range Strapping 3-10 Seconds None 11-30 Seconds A1-A7 31-100 Seconds A1-A2-A7 101-300 Seconds A1-A2-A3-A7 SIave ReIay VoItage Strapping 12 V DC D1-D2 24 V DC D2-D7 50 V DC D2-D8 TY370/GRP01 is a slow release timer module which adds a release delay to a slave relay. When a control contact connected to terminals D3/D4 is opened the delay is added between the control contact opening and the relay connected to terminals R3 and R4 being opened. The safety critical nature of this design does not allow the release delay to alter by more than 20% from the set time. The TY370/GRP01 is operated from a 12 V DC or full-wave rectified AC supply and generates a 12 V, 24 V or 50 V supply to operate the slave relay. TerminaI Arrangements. A B C D 1 Timing Timing F F 1 2 2 3 Timing Timing F F 3 4 4 5 Timing Timing S B 5 6 6 7 Timing Timing F B 7 8 8 R1 COIL COIL R2 R3 R4 5F 2B TY372/GRP01 REAR VEW OF RELAY Timing Timing Timing Timing Timing Timing Timing Timing F = Front contact, which is made when the relay is energised. This is a normally open contact. B = Back contact, which is made when the relay is de-energised and the armature has completed its maximum travel. This is a normally closed contact. Contact Arrangements. On applying power to the relay the display illuminates all segments for 0.5 seconds to allow the engineer to identify any dead segments.
For the remainder of the delay the total delay time is displayed.
Once the relay has timed out the display shows - - - -.
When no power is applied to the relay no segments are illuminated. TY372 DispIay Information AIways re-adjust the potentiometer when the reIay is repIaced. A B C D 1 Timing Timing F F 1 2 2 3 Timing Timing F F 3 4 4 5 Timing Timing S B 5 6 6 7 Timing Timing B B 7 8 8 R1 COIL COIL R2 R3 R4 4F 3B TY372/GRP02 REAR VEW OF RELAY Timing Timing Timing Timing Timing Timing Timing Timing 2010 - STS Rail Ltd Page 3 of 4 TY370/GRP01 & TY372/GRP01-02 SLOW RELEASE & OPERATE DELAY UNITS STD S T S
C a t a l o g u e
N u m b e r
C o i l
# 1
R e s i s t a n c e
P o w e r
C o n s u m p t i o n
F u l l
O p e r a t e
R e l e a s e
F u l l
R e l e a s e
C o n t a c t
R a t i n g
C o n t a c t
R e s i s t a n c e
W e i g h t
( K g )
TY372/GRP01 TY372/GRP02 1750 C 1.43 W 40 V 7.5 V N/A 3 A 0.2 C 1.0 kg On applying power to the coil connections all the segments on the display illuminate allowing the op- erator to identify and dead segments, then show the operate delay time. Once the relay has timed out the display indicates - - - -. Adjusting the potentiometer whilst the operate delay time is showing displays a live indication of the actual time delay allowing rapid setting
The dispIay is for indication onIy. On setting the reIay the actuaI time deIay shouId be manuaIIy checked as it wouId be on a reIay without a dispIay.
Units are shipped with the potentiometer turned all the way down. 2010 - STS Rail Ltd Page 4 of 4 TY370/GRP01 & TY372/GRP01-02 SLOW RELEASE & OPERATE DELAY UNITS STD NominaI Time (S) Coarse Strapping Fine Strapping NominaI Time (S) Coarse Strapping Fine Strapping 2.5 A1-B7 B7-B8 167 A1-A4 B7-B8 7.5 B7-A8 173 B7-A8 13.5 A8-B8 178 A8-B8 18.5 No Strap 184 No Strap 26 A1-A7 B7-B8 191 A1-B3 B7-B8 31 B7-A8 196 B7-A8 37 A8-B8 202 A8-B8 42 No Strap 207 No Strap 50 A1-B6 B7-B8 214 A1-A3 B7-B8 55 B7-A8 220 B7-A8 61 A8-B8 226 A8-B8 66 No Strap 231 No Strap 73 A1-A6 B7-B8 238 A1-B2 B7-B8 78 B7-A8 243 B7-A8 84 A8-B8 249 A8-B8 89 No Strap 254 No Strap 97 A1-B5 B7-B8 262 A1-A2 B7-B8 102 B7-A8 267 B7-A8 108 A8-B8 273 A8-B8 113 No Strap 278 No Strap 120 A1-A5 B7-B8 285 A1-B1 B7-B8 125 B7-A8 290 B7-A8 131 A8-B8 296 A8-B8 136 No Strap 301 No Strap 144 A1-B4 B7-B8 309 B7-B8 149 B7-A8 314 B7-A8 155 A8-B8 320 A8-B8 160 No Strap 325 No Strap No Strap Strapping shouId be as short as practicaI and made using appropriate signaIIing cabIe. As shipped the time deIays are set to the IeveIs beIow by fixing the strapping detaiIed between the pIugboard connectors. RepIacing the reIay wiII therefore automaticaIIy set the new reIay to the same time range. A potentiometer accessed through a hoIe in the cover can increase the time deIay from nominaI by up to 9.4 seconds in 0.1 second increments. Once adjusted the hoIe in the cover must be re-seaIed by a tamperproof 'CALIBRATION VOID IF BROKEN' IabeI provided. AIways re-adjust the potentiometer when the reIay is repIaced.
P r e l i m i n a r y P r e l i m i n a r y
Australian Distributor
Relay Monitoring Systems Pty Ltd 6 Anzed Court Mulgrave, Victoria, 3170, Australia