You are on page 1of 3

PROCEDURE TO CARRY OUT PREVENTIVE MAINTENANCE ON TELLABS 7100 NODES

TELLABS 7100 PREVENTIVE MAINTENANCE

TELLABS 7100 NANO

MAIN SHELF 1

FAN FILTER FAN MODULE

MAIN SHELF 15
T LA I

I NT VE ON

(N/A IN MOST METRO NODES)

PORT SHELF 2

PORT SHELF 3

FILTER HANDLE

HANDL E

LEVER S

FILTER LOCK

POWER LED

FAULT LED

STEP 1 PULL BACK THE FAN LOCK WHICH ALLOWS FOR THE REMOVAL OF THE FAN FILTER, THEN BLOW OFF THE DUST TRAPPED IN IT WITH A BLOWER. AT THIS POINT AN AMBER LIGHT APPEARS ON THE FAULT LED ON THE FAN MODULE STEP 2 RETURN THE FAN FILTER TO ITS SLOT, WAIT FOR THE AMBER LIGHT ON THE FAN MODULE FAULT LED TO TURN GREEN, ONCE GREEN , WAIT FOR SOME SECONDS AND THEN PULL OUT THE FAN MODULE BY SLIDING THE TWO LEVERS ON THE FAN MODULE AND PULLING OUT THE FAN MODULE. USE A BLOWER AND A BRUSH TO GET RID OF ANY DUST/DIRT TRAPPED IN. NB: MAKE SURE THIS IS ACHIEVED IN 2 3 MINUTES. STEP 3 PUSH BACK THE FAN MODULE INTO ITS SLOT AND WAIT UNTIL BOTH LEDs (POWER AND FAULT) ON THE FAN MODULE TURN GREEN. STEP 4 REPEAT STEPS 1 3 ON ALL THE SHELVES (MS_1, MS_15,PS_2,PS_3) OR (MS_1,PS_2) AS THE CASE MAY BE.