Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

Introduction
Many modern engineering structures require a foundation system that provides adequate support by resisting loads that are imposed on the foundation of the structure or vertical and horizontal pullout forces. Stability and support of structures is provided by transferring foundational loads from the structures foundation through some form of anchors and then onto the surrounding soil and terrain. In many cases these loads and forces that are transmitted through anchors to surrounding terrain can cause the anchor to experience subsequence uplift forces .As a result, ground anchors have been developed so as to be fixed to structures and are embedded to sufficient ground depths to provide adequate amounts of support within required safety limits. It is therefore the primary focus of this project and subsequent dissertation to investigate the uplift capacity of various ground anchors in sand.

Ground anchors have in fact been utilised for thousands of years in many different forms. Predominantly the use of these early anchors was to support lightweight structures only and it was not until recent times with the invention of suspension bridges that anchors were used to transfer very large loads. As a result, during the last 50 years there have been a number of studies conducted to investigate the design and use of these ground anchors. A number of theories have been developed to estimate the ultimate uplift capacity of different ground anchors in sand and it is the aim of this investigation to take a predominantly physical approach to further investigate and test this pullout phenomenon. A Basic twodimensional situation shall provide the primary focus of this investigation, however some initial investigation into three--dimensional effects shall be conducted and will therefore provide opportunity for further works in this area.

Ground Anchors
As mentioned ground anchors are generally designed and constructed to resist the forces that are applied to foundations of structures. The primary function of these anchors is to transmit the forces acting on the foundations of a structure to the surrounding soil or terrain. This simple form of buried anchors have been around for thousands of years and used to stabilise structures. An early example of this is the use of anchors or stakes that are buried to stabilise a tent. Initially ground anchors were only used to stabilise small or lightweight structures such as transmission towers, radar towers or tents as explained in the above example. It was not until
UVCE,Bangalore
Page 1

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

the mid 19th century when the creation of large suspension bridge structures introduced the need of ground anchors to bear and transmit very large loads to the earth. From this point in time forward, anchors began to form an important component of many civil engineering projects and in many of these cases be required to resist some form of uplift forces. Ground anchors have been developed since this time into a number of different forms each with its own strengths and specific applications. Generally anchors can be classified into five different forms of ground anchor that are currently in use in industry and they are as follows: plate anchors, direct embedment anchors, helical anchors, grouted anchors, and anchor piles and drilled shafts. This project shall primarily focus on the plate anchor, pile anchors and shall further investigate buried pipelines in sand.

Plate Anchors
Plate anchors can be constructed using a many number of materials and can be constructed in numerous shapes. For example plate anchors may be made of steel plates, precast concrete slabs, poured reinforced concrete slabs or timber sheets just to name a few of the most common construction materials. Plate anchors may also be put into location in a number of ways, the two most common methods utilised today are backfilled plate anchors or excavated trench plate anchors. Backfilled plate anchors are put into position by excavating the ground to the required depth, placing the anchor in position then backfilling and compacting with good quality soil. The other popular method of deposition is to install the plate anchor in excavated trench, then attach the anchor to tie rods that are either driven or placed through auger holes. (Das 1990). The methodology used throughout experimentation in regards to this project will replicate the deposition method of backfilled plate anchors.

Pile Anchors
Anchor piles can be used to support both compressive loads or resist uplift loads, or in certain circumstances act as lateral restraints. Piles are used when the structure is subject to very large loads or in instances where surrounding soil conditions are poor and require footings to pass to great depths to reach acceptable soil conditions. When the soil located immediately below a given structure is weak, the load of the structure may be transmitted to a greater depth by piles and drilled shafts (Das 1999).Some structures, like transmission towers, mooring systems for ocean surface or submerged platforms, tall chimneys, jetty structures, etc., are constructed on pile foundations, which have to resist uplift loads (Chattopadhyay
UVCE,Bangalore
Page 2

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

and Pise 1986). Just as with plate anchors, piles can be made from many materials and be formed into numerous shapes. They too can be created from steel, precast concrete, poured concrete or timber and may be formed into shapes such as square, circular or octagonal piles. Also, as with plate anchors, piles can be driven into place or excavated into position. Piles are often more expensive to use then a shallow anchor of most types, but in many cases when piles are utilised it is because they are required for the specific situation. Pile foundations which are deep and which cost more than shallow foundations. Despite the cost, the use of piles often is necessary to ensure structural safety (Das 2004).

UVCE,Bangalore

Page 3

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

LITERATURE REVIEW
REVIEW OF RESEARCH FINDINGS RELATED TO BEHAVIOUR OF HORIZONTAL PULLOUT CAPACITY OF GROUP OF VERTICAL SRIP ANCHOR PLATE EMBEDDED IN SAND
Jyant Kumar(2001). The problem of finding the horizontal pullout capacity of vertical

anchors embedded in sands with the inclusion of pseudostatic horizontal earthquake body forces, was tackled in this note. The analysis was carried out using an upper bound limit analysis, with the consideration of two different collapse mechanisms: bilinear and composite logarithmic spiral rupture surfaces. The results are presented in non dimensional form to find the pullout resistance with changes in earthquake acceleration for different combinations of embedment ratio of the anchor (), friction angle of the soil (), and the anchor-soil interface wall friction angle (). The soil medium follows Mohr-Coulombs failure criterion and an associated flow rule. At failure, the back surface of the anchor is assumed to completely separate from the adjoining soil mass, that is, the backfill material does not exert any active thrust at all on the back surface of the anchor. Bilinear rupture surface

UVCE,Bangalore

Page 4

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

In the above equation, W0 and W1 are the weights of the blocks OAB and OBCD, respectively. The magnitude of Pu can then be minimized with respect to independent admissible variations of , 1, and 2 ; for a collapse mechanism to be kinematically admissible, the magnitudes of V1, V2, V10, and V21 in terms of V0 should always remain positive. It should be mentioned that for given values of b and H, the magnitudes of W0 and W1 will depend on , 1, and 2.

Composite logarithmic spiral rupture surface:

UVCE,Bangalore

Page 5

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

The variation of the pullout resistance for = 0.25.

The variation of the pullout resistance for = 0.50.

The variation of the pullout resistance for = 0.75.

UVCE,Bangalore

Page 6

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

In the above equation W0 and W2 are the respective weights of blocks OAB and OCDE, and Worklog is the rate of work done by the body forces (due to and h) within the logspiral zone OBC. This value was obtained mathematically using integration as

In the above expression ro is the length of the radius vector OB. Using eqs. [2] and [3], the magnitude of Pu can be obtained for a chosen admissible collapse mechanism; for a collapse mechanism to be kinematically admissible the magnitudes of V1, V10, and V2 in terms of V0 should remain positive. The magnitude of Pu can then be minimized with respect to the variations of and . Based on the above two mechanism they concluded that, the pullout resistance decreases quite substantially with increases in the magnitude of the earthquake acceleration. For values of up to about 0.250.5, the bilinear and composite logarithmic spiral rupture surfaces gave almost identical answers, whereas for higher values of , the choice of the logarithmic spiral provides significantly smaller pullout resistance.

MANAS KUMAR BHOI(2008). The ultimate uplift resistance of a group of multiple strip anchors placed in sand and subjected to equal magnitudes of vertical upward pullout loads has been determined by means of model experiments. Instead of using a number of anchor plates in the experiments, a single anchor plate was used by simulating the boundary conditions along the planes of symmetry on both the sides of the anchor plate. The effect of clear spacing (s) between the anchors, for different combinations of embedment ratio () of anchors and friction angle () of soil mass, was examined in detail.

UVCE,Bangalore

Page 7

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

UVCE,Bangalore

Page 8

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

The variation of pu,av/(d) with (/B) for different values of (s/B) for = 37.4 and

A comparison of obtained from the present study with the theory of Meyerhof and Adams .

UVCE,Bangalore

Page 9

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

Based on the experimental study they reported in terms of efficiency factor which was defined as the ratio of the failure load for an intervening strip anchor of a given width (B) to that of a single strip anchor plate having the same width. It was clearly noted that the magnitude of y reduces quite extensively with a decrease in the spacing between the anchors. The magnitude of y for a given s/B was found to vary only marginally with respect to changes in and . ADEL HANNA(2009): Passive earth pressure on embedded anchor plates constitutes a viable resisting force for the design of underground structures. In the current practice, these forces are empirically calculated, ignoring the effects of the depth of embedment and the level of consolidation of the surrounding soil, which takes place during plate installation on the in situ stress levels. Numerical model was developed using finite-element technique and the constitutive law of MohrCoulomb to simulate the case of a retaining wall partially supported by an embedded anchor plate in sand, the coefficient of Passive earth pressure (kp) acting on the anchor plate was given by

where Pult = ultimate load, ha = height of anchor plate, H = depth of top edge of the anchor plate from the ground surface, = friction angle between soil and the anchor plate, and Pult = ultimate load (at the maximum mobilized passive earth pressure).

UVCE,Bangalore

Page 10

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

Based on the numerical study they reported that passive earth pressure acting on anchor plates increases due to the increase of angle of shearing resistance and the overconsolidation ratio of sand, and it decreases due to an increase of the embedment depth of anchor.

PARAMITA BHATTACHARYA(2011). The horizontal pullout capacity of a group of two vertical strip anchor plates placed along the same vertical plane in sand, has been determined by using the lower bound finite element limit analysis. The effect of vertical spacing (S) between the anchor plates on the magnitude of the total group horizontal failure load (PuT) has been determined for different combinations of H/B, / and . The magnitude of PuT has been obtained in terms of a group efficiency factor, , with respect to the failure load for a single vertical plate with the same H/B.

UVCE,Bangalore

Page 11

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

PuT = Pu1 + Pu2

Where, For front and backface (RT) Front and backface (OP) where Pu1 and Pu2 are the pull out load (per unit length of the strip plate) for lower and upper anchor, respectively. Group Efficiency Factor:

UVCE,Bangalore

Page 12

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

where Pu and PuT refer to the failure loads for a single and a group of two anchors, respectively, by keeping the value of H/B to be exactly the same in both the cases.

Based on the above study they concluded that , An increase in the value of and H/B leads to generally a very marginal increase in the value of Scr/B. On the other hand, the changes in the value of do not seem to have any significant effect on Scr/B. An increase in the value of , and H/B generally tend to cause some increase in the values of max.

HAMED NIROUMAND AND KHAIRUL ANNEAR KASSIM (2011) Numerical analysis and laboratory works were performed to study the performance of the ultimate uplift load capacity of the anchor plate. The behavior of square anchor plates during vertical pullout was studied by experimental data and finite element analyses in dense sand. Validation of the analysis model was also carried out with 100 mm x100 m square plates in dense sand. Agreement between the uplift capacities from the experimental test sand finite element modeling using PLAXIS 2D, based on 0.2 m computed maximum displacements was excellent for square anchor plates. Numerical analysis using square anchor plates was conducted based on hardening soil model.

UVCE,Bangalore

Page 13

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

From above both experimental and numerical analysis they conclude that the test performed in the glass box showed that the limited ultimate capacity of the square anchor plate model was influenced by the embedment ratio and the sand density. Typically, the results from PLAXIS had a good agreement with the experimental results obtained from the prediction of the uplift load capacity on the square anchor plate. These can be used to provide the basis for the design of such structures in the sand.

UVCE,Bangalore

Page 14

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

Conclusion from previous study


The pullout resistance decreases quite substantially increases in the magnitude of the earthquake acceleration. for values of up to about 0.25-0.5, the bilinear and composite logarithmic spiral provides significantly smaller pullout resistance. The results compare favourably with the existing theoretical data. The results produced in this investigation showed that the passive earth pressure acting on anchor plates increases due to the increase of angle of shearing resistance and the overconsolidated ratio of sand, and it decreases due to an increase of the embedment depth of anchor. Design theories were developed for the case of embedded anchor plate in overconsolidated sand. The theories developed will satisfy the design needed in terms of allowable pullout load and/or displacement. The magnitude of the group failure load becomes maximum corresponding to a certain critical spacing between two anchors. The value of Scr//B has been found to exist generally between 0.5 and 0.8 for different cases considered in this study. As compared to a single vertical anchor, the magnitude of the group failure load for two anchors, with the same H/B, has been found to increase up to a maximum of 43% for the different cases. For given values of S/B and H/B, the value of for two vertical anchors increases continuosly with an increase in the values of embedment ratio, angle of internal friction of sand and anchor-soil interface friction angle. It was clearly noted that the magnitude of reduces quite extensively with a decrease in the spacing between the anchors. The magnitude of for a given s/B was found to vary only marginally with respect to changes in and The test performed in the glass box showed that the limited ultimate capacity of the square anchor plate model was influenced by the embedment ratio and the sand density. These can be used to provide the basis for the design of such structures in the sand. There was no overall agreement found between the results in this work and the numerical modelling by PLAXIS 2D regarding the uplift capacity and the embedment ratio. However , close agreements were found with the numerical modelling for particular embedment ratios and the experimental results

UVCE,Bangalore

Page 15

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

Finally we found more numerical analysis than experimental analysis from the literature survey and hence we would conduct the experimental analysis for determining the pullout performance of vertical strip anchors embedded in sand

UVCE,Bangalore

Page 16

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

Materials and Method:


The mild steel tank of size - (1.2 m * 0.75 m* 1.5 m ) Anchor plate of size-(100*100*10)mm (150*150*10)mm are used for the Proposed study.

A coarse graded sand is used for the study. The Properties of sand used the Proposed work is given by: Uniformity coefficient Coefficient of curvature Specific Gravity Maximum Unit Weight(max),emin Minimum Unit Weight(min), emax 3.75 0.91 2.65 17.8 kN/m3,0.460 14.16 kN/m3,0.624

The experiments are performed on three different unit weight of soil.

Sl.no 1 2 3

Relative Density 20% 50% 80%

Natural void ratio

Dry density 16.339 16.85 17.41

Angle of internal friction

0.591 0.542 0.493

UVCE,Bangalore

Page 17

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

Experimental Setup of the Proposed work:

Solid Mild steel anchor plate of (100 *100)mm and (150*150) mm square are used in the proposed experimental study. The anchors are kept in vertical position with spacing varying at 0, 1 and 2 times the width of Anchor. The technique of sand placement plays an important role in the process of achieving reproducible density. After proper placement of the anchors in tank, sand was poured in the tank by calibrating the height of fall through funnel. This technique of sand pouring is termed as rainfall technique and this technique was reported to achieve good reproducible densities. The sand surface was levelled carefully. This method of sand pouring gives a predetermined dry density of loose, medium and dense sand. Pullout load is applied to the anchor through a pulley arrangement with flexible wire attached to connecting rod, Dial gauge readings corresponding to axial displacements were recorded.
UVCE,Bangalore
Page 18

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

REFERENCES

ADEL HANNA (2011) Passive earth pressure on embedded vertical plate anchors in sand ,Acta Geotechnica 6: 21-29

HAMED NIROUMAND AND KHAIRUL ANUAR KASSIM (2011) Uplift response of square anchor plates in dense sand ,International journal of the physical sciences (6(16)):3939-3943

JYANTH KUMAR(2001) Seismic horizontal pullout capacity of vertical anchors in sands, can Geotech 39:982-991

JYANTH KUMAR AND MANAS KUMAR BHOI (2009) Vertical uplift capacity of equally spaced multiple strip anchors in sand,Geotech Geol Eng 27: 461-472

PARAMITA BHATTACHARYA (2011) Horizontal pullout capacity of a group of two vertical strip anchors plates embedded in sand, 30:513-521

UVCE,Bangalore

Page 19

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

UVCE,Bangalore

Page 20

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

UVCE,Bangalore

Page 21

Horizontal pullout capacity of Group of Vertical Square Anchor Plate Embedded in Medium to Dense Sand

UVCE,Bangalore

Page 22