SETTING THE LANGUAGE


Choose the Language from pop up Click the Instrument Settings soft key. Select Press Restart Enter. language the device. soft key. the System key. menu. Use Up/Down Key.

Enter

Chinese

Created by: Engr Russell Salazar FM Engineer Mobily 3G Project

DTF ( DISTANCE TO FAULT) MODE


PROCEDURE:
o o o o o o Enter the Start and Stop Frequency or choose the Band from Band List key. Choose which type of cable is used. Click Cable List menu. Calibrate the device. Set the total distance i.e. from NodeB to Antenna port (length of Jumper Cablesindoor and outdoor, and Feeder Cable) Set the Max and Minimum Amplitude, click Amplitude (1) soft key. Set the Marker (4) . Marker 1 (indoor jumper), Marker2 (Feeder), Marker3 (outdoor Jumper) Press Hold (+/-) button to start the measurement. Press Peak (6) button to see the maximum value of your measurement and see the corresponding distance from your marker.

o o

Created by: Engr Russell Salazar FM Engineer Mobily 3G Project

DTF MODE
FREQUENCY BAND
Enter the Start and Stop Frequency or choose the Band from Band List key.

Created by: Engr Russell Salazar FM Engineer Mobily 3G Project

DTF MODE
CABLE TYPE
Choose which type of cable is used. Click Cable List menu.

Created by: Engr Russell Salazar FM Engineer Mobily 3G Project

DTF MODE
CALIBRATE: OPEN
Calibrate the device. Press Cal button key.

Connect OPEN to RF port and then press continue.


Created by: Engr Russell Salazar FM Engineer Mobily 3G Project

DTF MODE
CALIBRATE: SHORT

If OPEN calibration is completed, Connect SHORT to RF port and then press continue
Created by: Engr Russell Salazar FM Engineer Mobily 3G Project

DTF MODE
CALIBRATE: LOAD

If SHORT calibration is completed, Connect LOAD to RF port and then press continue.

Created by: Engr Russell Salazar FM Engineer Mobily 3G Project

DTF MODE
DISTANCE
Set the total distance i.e. from NodeB to Antenna port (length of Jumper Cables--indoor and outdoor, and Feeder Cable), then press Enter key.

Created by: Engr Russell Salazar FM Engineer Mobily 3G Project

DTF MODE
AMPLITUDE
Set the Max and Minimum Amplitude, press Amplitude (1) soft key
Max (top) Min

Max value should be higher than the VSWR alarm value . For example, from LMT MML DSP VSWR, the value measured is 280(.01), Max value should be at least 4 or 5. Min value should at least be the ideal value, 1. Created by: Engr Russell Salazar
FM Engineer Mobily 3G Project

DTF MODE
MARKER
Set the Marker (4) . Marker 1 (indoor jumper), Marker2 (Feeder), Marker3 (outdoor Jumper)
Marker Select Marker Off on

Marker Edit

Mark the length of your cable, say indoor jumper cable=3m, feeder cable=35m,outdoor jumper cable=3m. M1=3, M2=38, M3=41.
Created by: Engr Russell Salazar FM Engineer Mobily 3G Project

DTF MODE
RUN/MEASURE
Connect the RF cable to the RF Port. Press Hold (+/-) button to start the measurement

Created by: Engr Russell Salazar FM Engineer Mobily 3G Project

DTF MODE
PEAK VALUE
o Press Peak (6) button to see the maximum value of your measurement and see the corresponding distance from your marker.

Settings: START FREQ =1920 Mhz STOP FREQ = 2170 Mhz CAL ON DISTANCE = 40m M1=4m
M1

M1: 3.9m/2.0

Created by: Engr Russell Salazar FM Engineer Mobily 3G Project

DTF MODE
LOAD SET-UP
o If you have saved set-up configuration ( .sta), you can load it using the Load Button (7) . This will save time by not performing the calibration for the equipment. Only change the Cable type, Distance, Marker and or Amplitude if necessary.

Created by: Engr Russell Salazar FM Engineer Mobily 3G Project