Hunter offer a complete range of plastic plumbing products for gravity soil and waste installations. With a choice of Solvent Weld or Push-Fit jointing systems, our systems match almost all installation requirements. As construction trends move towards high density housing and off site construction, our plumbing range has evolved to include innovative fire protection and Grease Management. This guide has been compiled to assist you to select your system of choice by jointing method, through to size, colour or application.
Plumbing Contents
Soil Systems Solvent Features & Benefits Products Push-Fit and Solvent Features & Benefits Products Jointing Procedure 7 9 13 17 19 21 31
WC Connectors
35 37 39
43 46
Waste System
Introduction Products
55 57
Plumbing Contents
Fire Protection
Introduction
41
Plumbing Contents
Solvent Weld Introduction Products 59 61
Overflow
Introduction Products
63 65
Pipe Carrier
67 69 69
Grease Management
71 73 79
Compatability Chart
89
Contact Details
91
Plumbing Contents
Soil Systems
Whether your preference is solvent weld or push-fit assembly, Hunter Plastics Soil Systems offer a comprehensive above ground plastic drainage system; suitable for carrying sanitary waste from domestic, commercial and industrial installations. The installer has the flexibility to select either Hunters Push-Fit or Solvent systems.
Soil Systems
System Benefits
Needs no protection from ultra violet light when used externally Smoother cleaner lines Broader colour range of wastes Solvent systems cannot be disturbed by other trades after installation
Solvent Soil Stack typical installation A A B C D E F G H J K S355 VENT COWL S271 OFFSET BEND S271 OFFSET BEND S210 DOUBLE SOCKET S220 SOCKET BRACKET S215 SHORT BOSS PIPE S280 ACCESS BRANCH S293 DOUBLE SKT. BEND S217 PIPE BRACKET S310 ACCESS PIPE
B C D E
G J
Strap-On Boss
Allows a retro-fit soil stack waste connection that can be adapted to 32mm, 40mm and 50mm, simply make a hole in the pipe using a 54mm hole cutter. Remove swarf and apply Hunter Solvent Cleaner to back of boss flange and pipe, then simply cement in place. The Strap Boss is uniquely designed to be fixed without the need of a nut and bolt through a simple ratchet action. Provision is made, however, if a nut and bolt fixing is required.
Expansion Joint
Regulations state that after every 6m of solvent weld plumbing you must incorporate an expansion joint. Simply solvent weld the adaptor onto any solvent weld socket to convert for expansion.
Fixed point due to Socket Bracket. Expansion between fixed point and drain connection taken up within drain socket. If a solvent welded fitting is provided on the ground floor it should be fitted with an Expansion Socket.
11
Soil Systems
Pipe Plain Ended
Product Code
110mm
9212 Double Solvent Socket S293 135 Double Solvent Socket S294
Soil Systems
Product Code
110mm
S271
S330
S302 9212 Double Solvent Socket Spigot Tail 5 Closed Bosses 9212 Double Solvent Socket Spigot Tail No Bosses Double Branch S300
(Fabricated)
S297
Soil Systems
Access Branch
Product Code
110mm
S280
S337
Short Boss Pipe 32mm Expansion Socket S216 40mm Expansion Socket S215 50mm Solvent Socket for 32/40mm solvent weld use W104 or W106 adaptors S218
Soil Systems
Strap-On Boss
Product Code
110mm
Snap-Fit. No bolt Supplied 54mm Hole Cutter Accepts 32mm, 40mm and 50mm Boss Adaptors
(See Page 24 For Boss Adaptors)
S343
Reducer Spigot Tail 110mm x 82mm Spigot Tail 160mm x 110mm S636 S420
Expansion Adaptor Ring Seal Adaptor For any Solvent Socket Vent Cowl S355 S201
15
A B
D E F
G H INternal Stack a S355 VENT COWL B S594/S596 WEATHERING SLATE C S217 1 SCREW PIPE BRACKET D S334 branch E S221 WC Connector F S200 waste manifold G S508 pipe-Socketed H S220 Bracket socket J S244 Boss pipe (spigot tail) K S208 single socket L S309 Access Pipe J K
17
To WC
b a
70mm 60mm To basin 50mm 40mm 30mm 20mm To bath 10mm f/L
Bath
Note: If the distance to the bath exceeds 3000mm Building Regulations state a 50mm Pipe must be used.
How To Install
The valve must be solvent welded in a vertical position to the top of the internal stack above flood level of the highest appliance allowing the soil stack to be terminated internally, however when terminating the stack in loft space, a polystyrene insulating cap (S451) must be used. The valve incorporates a socket for solvent welding to 110mm UPVC pipe to BS 4514. Using an adaptor, the valve may be connected to cast iron.
Please Note - Care must be taken to prevent contamination of moving parts.
19
82mm
110mm
160mm
Pipe Plain Ended 1m length 3m length S599 S204 S505 S506 S534 S535
S208
S406
Bracket Pipe, 1 screw Pipe, 2 screws Socket S612 S607 S217 S219 S220 S570 S571 S412
Pipe/Socket
82mm
110mm
160mm
S608
S244
Short Boss Pipe 32mm Expansion Socket* 40mm Expansion Socket* 50mm Solvent Socket S216 S215 S218
Soil Systems - Push-Fit & Solvent 21
*Accepts Push-Fit and Solvent Pipes For 32/40mm solvent weld use S218 & W104 or W106 adaptors
S610
S343
S437
Waste Manifold For 32mm use with W58 For 40mm use with W59 For 50mm use with W725 S200
82mm
110mm
160mm
Access Saddle
(Direct Fix to Pipework)
S337
Socket Plug
lso for on-site A socket protection
S214
S411
S450
Polystyrene Insulator
S451
(for S450)
Soil Systems
Boss Adaptors
Product Code Product Code Product Code
32mm
40mm
50mm
Creates Solvent Connection to Boss For Solvent Pipe Only Straight W104
Use W104
W106
Use W106
S750 W725
90
+ W111
+ W112
Creates Push-Fit Connection to Boss For Push-Fit and Solvent Pipe W58 W59 S751
W58
W59
S751
32mm
40mm
W58
W59
32mm
40mm
50mm
W104
W106
S750
82mm
110mm
160mm
104
S427
135
S614
Solvent Socket Top and Bottom 3 Closed Bosses 9212 Adaptor Branch - Double Equal Adaptable from 9212 11212 For 92 use 2 x S323 For 104 use 2 x S324 For 11212 use 2 x S208
1 2
S340
S308
82mm
110mm
160mm
Triple Expansion Socket (Fabricated) Corner Branch Triple Expansion Socket (Fabricated) Branch (Single Unequal)
S296
Multiflex Branch 10mm x 110mm (grey) 1 MFYDG Expansion Socket Spigot Tail Adjustable 45 90 No Bosses
110mm x 110mm (grey) MFYDB Expansion Socket Spigot Tail Adjustable 45 90 No Bosses
25
S471
82mm
110mm
160mm
Adaptor Bend 160 to form 9212 170 to form 104 Access Bend 9212 Bend 9212 Spigot Tail
1 2
S323 S324
S620
S326
S619
S322 S319
S403
92 Solvent Socket Tail S626 9212 Expansion Socket Tail 104 Spigot Tail 11212 Spigot Tail 135 Spigot Tail S621
82mm
110mm
160mm
Top S630 S270 11212 Solvent Socket Tail S631 S700 S271 S263 S676
S425 S436
Connector
DS349
MKEP110
Eazisleeve complete with S/steel Clips Drain Adaptor Coupling DS26 DS28 DS27
PVC-PVC Adaptor
27
82mm
110mm
160mm
S668 S264
110mm x 50mm
Spigot accepts Push-Fit or Solvent Boss Adaptor (order separately)
110mm x 82mm
(expansion socket)
S633
160mm x 110mm
S420
110mm x 32/40mm
(Flexible)
DS25
110mm x 32/40/50mm
(Flexible)
S355
S422
82mm
110mm
160mm
30ml Lubricant 250ml Lubricant 300ml Silicone spray 125ml Solvent cleaner 125ml Solvent cement BS6209 for PVC 250ml Solvent cement BS6209 for PVC
To achieve a secure watertight joint it is important that you prevent the seals from being forced from their housing in the fitting. Therefore it is essential that the pipe is chamfered, free from swarf and suitably lubricated (use only recommended Silicone Lubricant, as other lubricating matter could degrade the quality of the seal).
Jointing Procedures:
Soil Push-Fit
Cut pipe square, using a fine tooth saw. Use a pipe cutting template or wrap paper around pipe as guide line.
Chamfer end of pipe, using medium file or rasp. Standard lengths of pipe are already chamfered.
Withdraw pipe (10mm). This will allow for expansion. All fittings must be supported by a bracket.
Jointing Procedures:
Soil Solvent
Cut pipe square, using a fine tooth saw. Use a pipe cutting template or wrap paper around pipe as guide line.
31
Soil Systems
WC Connectors
Hunter WC Connectors are manufactured in accordance with BS5627 for water and air-tightness - that means no call backs! Key Benefits The WC connectors range are compatible with a variety of pipework materials including clay, cast iron and PVC-u Manufactured in Polypropylene and PVC-u H unter pan connectors incorporate all-purpose tails allowing simple, watertight installation Fixed and flexible options A Margin For Error If pipework is misaligned by more than a few millimetres, using a standard connector could lead to leaks. The offset connector allows up to 22 mm difference between centres. WC Connectors 35 A Simple Adjustment The adjustable WC Connectors are designed to connect up to five separate pans, using a single common pipe. They suit BS5503 horizontal outlet pans and can accommodate up to +/-2 degrees movement on the joint between the branch and WC connector.
WC Connectors
A Simple Connection
WC Connectors have all-purpose tails, for easy speedy connection. There is a Hunter WC Connector for most installations. From a straightforward job to multiple connections and misaligned pans, Hunter WC Connectors take the hard work out of the job. WCs can be connected directly to a drain using Hunter WC connectors without individual venting, provided that the vertical distance from the crown of the trap to the invert of the drain is no more than 1.5m in accordance with current Building Regulations.
Compatible with the following: 110mm PVC-u to BS4514: 2001 110mm PVC-u to BS EN1329: 2000 110mm PVC-u to BS EN1401: 1998 102mm Cast Iron to BS416: 1990 100mm Clay to BS EN295: 1991
WC Connectors
Space Saver
Can save up to 55mm in installations. It is ideal where a traditional seperate WC pan and cistern is being replaced by a close-coupled suite.
Adjustable 5- 30
This connector is ideal fitting for when you are connecting up to five pans in a row, using one common pipe as the adjustment allows the pan to connect to the gradient of the float system. WC Connectors 37
S253 5 to 30
Branch connection
WC Connectors
Product Code
110mm
Space Saver
S234
14
S222
Straight Connector
(Reducible length)
S224 S227
Straight Connector
S225
Extension Piece
(Reducible length)
S226
WC Connectors
Product Code
110mm
S252
Adjustable 5- 30
S253
Straight Connector Solvent Socket Tail Pipe Plain Ended 1m length Gasket
S231
S204
For use with BS5503 Pans Fits S253 and all 110mm Expansion Sockets Fits S251 and S252
S298 S291
39
WC Connectors
For Use With BS1213 Pans Fits S231 102 - 120mm Spigots
S248
Fire Protection
Hunter Plastics offer a comprehensive fire protection range, incorporating the innovative Quickstop Intumescent Coupling Unicollar and traditional Compact Fire Collar providing flexible and effective, fire protection solutions for the specifier and end user alike. When specifying or installing Hunter Fire Protection products, you can be confident that the range has been fully tested to ensure its suitability for not only with PVC pipework systems, but a variety of alternative plastic construction products. For full detailed performance data and/or installation procedures, please refer to the relevant technical data sheet.
Quick Stop
page 40
Uni-Collar
page 49
Compact Collar
page 52 41
Fire Protection
Quickstop
How Quickstop Works
Like all intumescent products Quickstop is activated when exposed to the heat of a fire, the exfoliated graphite material, (which uniquely with QUICKSTOP is part of the formulation used to mould the product), expands to crush the pipe and fill the wall or floor penetration. In doing so smoke and flames are prevented from passing for a period of time, known as the fire rating.
Typical Specification
Supply Hunter Quickstop (BBA Approved) Intumescent Coupling(s) to provide up to 2 HOURS fire resistance and suitable for PVCu pipe of 110mm diameter. To be installed in accordance with manufacturers guidelines, British Standard codes of practice and local Building Regulations.
The QUICKSTOP Intumescent Coupling is the first product of its kind in the UK to receive BBA approval.
Design
As the Quickstop coupling becomes an integral part of the drainage system and therefore a fixed point within that system, adequate allowance for thermal expansion/contraction must be made. To prevent stress cracks occurring in pipework it is essential that within 1metre of the penetration (wall or floor) a ring seal/expansion fitting is installed to accommodate such movement. Pipe should be cut square, chamfered and lubricated before insertion into the ring seal socket. To create an expansion gap, each spigot end must be fully inserted into the socket of the fitting and then withdrawn 10mm. At this point the fitting must be fixed to prevent it moving out of position.
Installing Quickstop
Clean pipe and socket with Hunter Solvent Cleaner. Apply Solvent Cement liberally to both pipe and coupling socket.
A pipe and coupling Join the together using a twisting action where possible to B ensure an even spread of Solvent Cement in the joint.
EnsureCthat the ends of the QUICKSTOP remains visible in-situ to allow activation in the event of fire. Make good with intumescent mastic.
Fire Protection
Product Code
The Quickstop Intumescent Coupling is a fire-stopping innovation, providing up to 2 hours fire protection as an integral part of the PVC pipework system 50mm 82mm 110mm QS050 QS082 QS110
110mm 82mm
C
50mm
45
Fire Protection
C Core Cut
Fire Protection
47
Fire Protection
UniCollar
The complete fire protection solution... in a box
UniCollar is unique using a one size fits all concept yet still provides the highest level of protection from the passage of smoke and flames through fire rated walls and floors, in the event of a fire. Providing up to 4 hours fire protection on a wide variety of pipe materials (dependent on application/construction) UniCollar offers significant savings over traditional compact collars, as it can be cut to suit a range of pipe sizes. Up to 4 hours fire rating dependent on application Convenient dispensing carton Complete installation flexibility cut length to suit Lightweight and easy to install B ox contains sufficient length for 5 x 110mm pipe collars
(8 x 50mm, 6 x 82mm, 3 x 160mm)
Independently tested with a wide range of plastic materials Approved to BS476 Part 20:1987 & prEN1366:Part 3
Normal Pipe Size Length Required Numbers of Segments
Total number of segments per box is 146, each segment measuring 15mm wide.
UniCollar
UniCollar is a unique method of protecting plastic pipes which pass through fire rated walls and floors. The system is supplied in continuous strip form which is cut to length and secured around to the pipework using ready-made clips. These clips fit into the pre-punched slots on the strip and are then fixed to the wall/floor using the fixings supplied. The intumescent (exfoliated graphite) activating layer is already attached to the metal band and requires no additional fixing.
Product Code
UniCollar Universal Fire Collar for 55mm to 160mm pipework (cut length to suit application). Up to 4 hour fire rating (BS476) Can make up to 5 x 110mm collars.
Suitable
CC001
Fire Protection
51
Fire Protection
Compact Collar
Features & Benefits of Compact Fire Collar
Ideally suited to maintenance and retro-fit applications the Hunter Compact Fire Collar is suitable for applications where up to 2 hours fire protection is required. The durable steel shell as well as supporting the intumescent material acts as a fixed surface, directing the crushing force of the fire activated collar inward, ensuring the effective sealing of fire rated compartment walls and floors.
Designed for use with the most common UK pipework size 110mm Fire tested up to 2 hours (dependent on application) Independently tested and approved to BS476 Part 20:1987 & prEN 1366:Part 3
Product Code
19mm flooring grade chipboard. 150mm x 50mm timber joists at 400mm centres. 25mm thick insulation between joists. 2 layers of 12.5mm Gypsum board.
53
Fire Protection
Waste Systems
Hunter Push-Fit waste systems Hunter Push-Fit waste systems are manufactured from durable polypropylene material which can withstand domestic hot water discharge and cope with the majority of chemicals and detergents. The 32mm and 40mm ranges are fully colour co-ordinated whilst the 50mm size is ideal for high discharge appliances and longer pipe runs. All products are manufactured to BS EN1451. Hunter Solvent waste systems Hunters high performance MuPVC Solvent Weld waste system manufactured to BS EN1566 is ideally suited for high temperature discharge applications and has excellent heat, UV stability and chemical resistance qualities. A comprehensive range is available in 32mm, 40mm and 50mm diameters.
55
Waste Systems
Waste Systems
Push-Fit
Product Code Product Code Product Code
32mm
40mm
50mm
Bend Swept 9212 Swept 135 Knuckle 90 Spigot 90 Spigot Bend 135 P010 P011 P017 P019 P061 P020 P021 P027 P029 P071 P200 P201 P207 P209
P013
P023
P203
P014
P024
P204
Waste Systems
Push-Fit
Product Code Product Code Product Code
32mm
40mm
50mm
P210
W58
W59 S751
W98
W99
Solvent Waste
Manufactured, where applicable to BSEN1566. Hunter Solvent waste is the system of choice for the pro plumbing installer, once welded the waste cannot be pulled apart, the rigid joints provide a permanent watertight connection and the Solvent Weld Waste system can be used externally, no need to paint as it will not degrade in UV light.
59
Hunter PVCuM waste system is manufactured to BS EN 1566 (or in thick wall PVCu as applicable). The system is designed for waste water discharge and should not be used as a high temperature gas boiler exhaust system (commonly referred to as a flue). For this type of installation, please refer to the Boiler manufacturers installation instructions and install a exhaust system as recommended.
Solvent Weld
Solvent Weld
Product Code Product Code Product Code
32mm
40mm
50mm
Pipe Plain Ended 4m length 3m length Coupling Socket Tail Straight W60 W61 W64 W711 W541 W538 W542 W710 W539 W709
W119 W121
W716 W122
W111 W116
Long Tail Spigot 92 W113 Swept 9212 Swept 135 Spigot 135 W78 W82 W108
135
Solvent Weld
Product Code Product Code Product Code
32mm
40mm
50mm
Cross 9212 Connector BSPT Adaptor Access Cap Spigot Tail W90 W91 W724 W125 W126 W723 W574 W722
Reducer Spigot/Socket 50mm x 40mm 50mm x 32mm 40mm x 32mm 32mm x 22mm Adaptors Waste Manifold Adaptor Bend Boss Adaptor Vent Cowl Balloon Grating Universal Tank Connector Accepts Push-Fit and Solvent Pipes W98 W99
61
W718 W717
W57
W55
W725 S750
W104
W106
S353
Overflow
Hunter Overflow pipes are manufactured in 22mm Polypropylene material for Push-Fit assembly, or PVCu for Solvent Weld assembly. The range of fittings, comprising couplers, elbows, tees and connectors are all manufactured in high temperature MuPVC material and may be used with Push-Fit or Solvent pipework systems. 22mm full bore discharge for efficient overflow removal Dual purpose fittings offer Push-Fit and Solvent Weld assembly Suitable for hot or cold water overflow installations
Overflow
Overflow
Product Code 22mm
Pipe Plain Ended 3m length PP (Push-Fit) O247 PVCu (Solvent Weld) O232 Universal Adaptor O220
Overflow
Product Code 22mm
Tee 90 O224
O245 Reducing Bush Push-Fit 32mm x 22mm Solvent 32mm x 22mm O233 W55
65
Overflow
Pipe Carrier
The Pipe Carrier has been designed to optimise capacity of a van. It enables plumbers and professionals of similar trades to transport up to a 3m length of 82mm pipe. Supplied with brackets for simple immediate connection to your vehicle. Reinforced caps to ensure heavy items such as copper pipe do not pierce the screwed caps. For additional safety and security a hasp & clasp is provided to allow padlocking. Integrated chain to assist with loading unloading the Pipe Carrier.
67
Pipe Carrier
Pipe Carrier
Product Code
S795 S796
Carries up to a 3m length of 82mm diametre pipe. Supplied with brackets for simple immediate connection to your vehicle. Reinforced caps to ensure heavy items such as copper pipe do not pierce the front end. For additional safety and security a hasp and clasp is provided to allow padlocking. Integrated chain to assist when loading/unloading the Pipe Carrier.
69
Pipe Carrier
Grease Management
It is estimated that 30% of all foul water blockages that result in property flooding are actually caused by grease. Grease interceptors are specially designed traps which are placed in the drainage system close to the sink to intercept and separate the fat, oil and grease (F.O.G) from the rest of the wastewater. Grease interceptors can be highly effective if they are correctly installed, serviced and maintained. The grease is retained in the trap to be collected for disposal or recycling (Typically for Bio Fuels) waste contractors who are able to deal with commercial F.O.Gs are licensed, and must provide a waste transfer note (under the environmental health act 1990, you have a responsibility to keep these notes for up to two years) To meet the requirements of your local environmental health officer.
71
Grease Management
Endura
Why Use a Grease Interceptor?
Grease and oil from commercial kitchens, etc poses a significant problem to sewage systems and treatment facilities.
C ongealed grease can clog sewer pipes, leading to expensive maintenance or even replacement. Local Water Authorities are increasingly recognising the need to protect their sewerage systems from grease and are requiring installation of Grease Interceptors (now being backed by building regulations).
73
Endura
1 2
Technical Specification
Diagram Elements 1. Nylon Reinforced polypropylene cover with easy lift latch 2. ORing seal for air and water tightness 3. Removable outlet baffle 4. Removable inlet baffle 5. Moulded one piece tank No leaks!
4 5
Description Flow rate L/Sec Grease capacity Operating temp. capabilities Cover load capacity Despatch weight
75
How it Works
ICD air entry
Influent
77
Grease Management
Endura Grease Interceptor Supplied complete with full installation instructions, ICD and flexible inlet/outlet connectors
COMPLIA
Product Code
BUIL 1.6L/sec NT
DSG16 DSG32
N G REG DI
PART
3.2L/sec
ATIONS UL
Supplied complete with Stainless Steel enclosure, 5L Bio-G, Programmable dosing pump and all fittings required to install
Grease Management
110mm Adaptor - Flexible
Product Code
DS28
Influent Control Device For use with DSG16 For use with DSG32 DSG16CD DSG32CD
Endura Installation
The Hunter Endura Grease Interceptor should be installed as close as is practical to the fixture(s) being served and can be set on, partially recessed or fully recessed into the floor. Note that the Endura Grease Interceptor is NOT recommended for above ground, external installation unless adequate protection from freezing is made. Sufficient clearance around the cover area should be anticipated to allow for routine maintenance, including the removal of accumulated grease. It is preferable that the Endura be located as close as possible to the appliances being served, up to a maximum of 8 metres from the last appliance. This precaution will prevent the waste pipes becoming clogged with congealed grease that could begin to solidify before reaching the Grease Interceptor.
such as waste disposal units. This type of unit must bypass the interceptor as rapid accumulation of solid matter will greatly reduce the interceptors efficiency preventing operation in compliance with the rated capacity.
typical IN FLOOR INSTALLATION a Appliance b Air intake c icd D rodding point E grease interceptor
B C D E
H J K
81
typical ON FLOOR INSTALLATION F Appliances G SOIL STACK H AIR INTAKE J ICD K grease interceptor
Interceptor Sizing
All Grease Interceptors are sized according to their maximum flow rate - This is measured in Litres per second. (L/sec) The Endura Grease Interceptor is available in two sizes. 1.6L/sec and 3.2L/sec.
Measurement Method A) Measure the sink left to right (cm) B) Measure the sink front to back (cm) C) Measure the depth of water (cm) B
To work out total number of litres in the sink multiply the answers as shown below:-
Answer A x Answer B x Answer C = D Divide Answer D by 1000 = Sink Capacity in litres Now you need to to time how long the sink takes to empty (in seconds):Divide the Sink Capacity in litres by the Time sink took to empty = Flow rate required. If the flow rate is under 1.6L/sec, then a DSG16 is suitable. If the flow rate is between 1.6 - 3.2 L/sec then a DSG32 is suitable.
figures together. When timing their discharge, ensure you pull the plugs at exactly the same time, to ensure accurate flow measurement. Dishwashers flow rate should be identified, however as a general rule of thumb, you can assume it will be equal to an additional sink.
Calculation Method
Grease Management 83 The maximum flow rate can be calculated by the following equation.
Q =
M x VF 2770 x t
Kitchen Type Hotel Restaurant Hospital 24hr Kitchen Canteen VF 500 425 260 220 100
Q M
Endura
The legal requirements relating to Grease Management
UK Building Regulations Part H 2002 states: Drainage serving kitchens in commercial hot food premises should be fitted a grease separator complying with BS EN 1825-1:2004 and designed in accordance with BS EN 1825-2:2002 or other effective means of grease removal. Under the Food Safety Act 1990. Local authorities are authorised to inspect problems arising from the effect of F.O.G (Fats, Oil and Grease) on drains, resulting in a failure to comply, could result in prosecution or an emergency prohibition order preventing trading from the premises. There is legislative power in section 111 of the Water Industry Act 1991 to take action against anyone that discharges any matter liable to cause damage to the sewerage system or to interfere with the free flow of its contents, this can include F.O.Gs.
Maintenance
As with all non-mechanical grease separators, the maintenance although essential to their effective operation, is considered an onerous and unpleasant task due to both the frequency of cleaning and removal of accumulate grease. The use of a system such as the Endura BioPak significantly reduces the frequency of interceptor/separator servicing by the introduction of a grease digesting product (in this case Bio-G) and means that a significant amount of the grease that would normally accumulate is broken down and digested. Dosing of the interceptor with Bio-G not only reduces the service frequency of the unit, but in addition protects the drainage system as a whole from grease accumulation and the commonly resulting blockage.
Endura Bio+
Introduced simply via any sink connected to the Grease Interceptor No pump or other equipment required Easy to handle 4 x 1kg containers Use daily for effective grease digestion
85
Endura
87
Endura
Compatibility Chart
Brett Floplast Hepworth Marley Osma Polypipe
Soil
4 4 4 4 4 4
4 4 4 4 4 4
4 4 4 4 4 4
4 4 4 4 4 4
4 4 4 4 4 4
4 4 4 4 4 4
4 4 4 4 4 4
4 4 4 4 4 4
89
Compatibility Chart
Why dont you have a look at some other great products by Hunter?
de to A Gui
2008
3/6/08
17:3
4:38
rgroun unde
d_AW
.indd
W.in
dd 1
4/8/08
To have a copy of either book sent out to you please contact us today!
Issue
rainw ater_
AW NE
16:12 :35
www.
hunt
erplas
tics.c
o.uk
Hunter Plastics Ltd Nathan Way London SE28 OAE Sales Hotline: +44(0)20 8317 1551 Tel: +44(0)20 8855 9851 Fax: +44(0)20 8317 7764 hunterplastics.co.uk email: hunplas@hunterplastics.co.uk
Due to a programme of continuous development, Hunter Plastics Ltd. reserve the right to revise or alter any information pertaining to their products without prior notice. All products are manufactured using a quality management system that has been assessed by BSI as complying with the requirements of BS EN ISO9001:2000 and BS EN 14001. Hunter holds many kitemark licences. Products conforming to the appropriate standards are kitemarked. Additional ranges are covered by BBA certificates or compatible European standards (ENs). All goods are sold according to Hunter Plastics Ltd standard conditions of sale, which are available on request. Hunter Plastics Ltd reserves the right, in view of their continuous programme of development, to revise or alter their range of products and prices without prior notice.
Uniclass CI/SfB
L7313:P71
J344:X71
EPIC
(52.3)
In6