1. A. B. C. D. 2. A. B. C. D.

Known as the Water Code of the Philippines RA 1080 PD 1067 RA 1037 PD 856 The Revised National Plumbing Code of the Philippines of 1999 was approved on June 18, 1955 January 28, 1959 November 28, 1967 December 21, 1999

3. Expiration of plumbing permit if suspended or abandoned for a period of A. B. C. D. 4. 60 days 365 days 120 days 180 days NAMPAP was organized and registered to SEC 195 4 199 9 193 5 195 0 Known as the Code on Sanitation of the Philippines PD 907 PD 865 PD 856 PD 586

A. B. C. D. 5. A. B. C. D.

6. The two causes of fixture trap seal loss that vent systems protect against in normal fixture use are A. B. C. D. backflow and back-pressure siphonage and back-pressure vacuum and backflow vacuum breaker and backflow preventer

7. Another term used to described a continuous vent is

A. B. C. D.

vent pipe vent stack stack vent soil stack

8. The trade name for relief vent is A. B. C. D. dual vent re-vent back vent cicuit vent

9. A vent connecting to a horizontal drain pipe through a fitting at an angle not greater the 45 degrees to the vertical is A. B. C. D. side vent back vent common vent yoke vent

10. The dry portion of a soil or waste pipe that extends above the highest horizontal drain connected to the stack and terminates above the roof is A. B. C. D. vent stack yoke vent stack vent dual vent

11. The function is to connect two or more vent pipes to the main vent at one point, or extend through the roof separately is A. B. C. D. 12. A. B. C. D. 13. A. B. C. D. vent exposed vent line vent header vent cap The purpose is to prevent the pressure changes in the stack relief vent yoke vent re-vent loop vent A positive pressure is siphonage back pressure vacuum backflo w

14. A. B. C. D. 15. A. B. C. D. 16. A. B. C. D. 17. A. B. C. D.

The negative pressure is called trap seal loss siphonage back pressure backflo w What will happen if the maximum fixture unit load increases the height of the vent pipe increases the height of the vent pipe decreases the height of the vent pipe maintains the height of the vent pipe doubles Minimum vent size for water closet is 1 inch. 2 inches. 2 1/2" inches. 3 inches. The smallest individual vent stack size permitted by the code is 1 1/4" 1 1/2" 1 " 2 "

18. A. B. C. D. 19. A. B. C.

The maximum vent size that can be used for a 3 inches drain pipe is 1 1/2" 2 " 2 1/2" 1 1/4" The factor that determines the maximum length of any vent pipe is invert diameter fixture load

D. 20. A. B. C. D. 21. A. B. C. D. 22. A. B. C. D.

color Kitchen sinks located away from walls or partitions are called slop sink center sink island sink isolated sink Maximum length of horizontal wet vent is 0.50 foot 1 foot 1 1/2 feet 2 feet Also known as the RA 9275 Water Code of the Philippines National Building Code of the Philippines Philippine Clean Water Act of 2004 Code on Sanitation of the Philippines

23. The first amendment of the National Plumbing Code which includes Asbestos-Cement pipe as approved plumbing materials was A. B. C. D. 24. June 18, 1955 December 21, 1999 November 28, 1967 January 28, 1959 How many provision of the Master Plumber Code of Ethics 6 7 8 9 How many set of plans return to the applicant after approval of permit 6 1 2

A. B. C. D. 25.

A. B. C.

D. 26.

4 How many set of plans retain to the jobsite after approval of permit 1 2 3 4 How many set of plans retain to the Administrative Authority after approval of permit 1 2 3 4

A. B. C. D. 27.

A. B. C. D. 28. A. B. C. D. 29. A. B. C. D. 30. A. B. C. D.

National Plumbing Code of the Philippines approved by the Malacaang June 18, 1955 January 28, 1959 November 28, 1967 December 21, 1999 Minimum volume of the digestive chamber of a septic tank 1 cu.m 2 cu.m 1.5 cu.m 2.5 cu.m The minimum difference in elevation of the inlet and outlet pipe of the septic tank 50.8 mm 102.8 mm 152.8 mm 204.8 mm

31. Standard conversion factor to multiply the TDH in feet to acquire the pressure in psi of

water in a pipe to a certain elevation A. B. C. D. 32. A. B. C. D. 33. A. B. C. D. 34. A. B. C. D. 35. A. B. C. D. 62. 4 0.43 3 32. 2 9.8 1 1 cubic meters of water is equal to 250 gallons 1500 liters 1000 kgs 2500 lbs. 1 cubic meters of water is equal to 10 liters 100 liters 1000 liters 10,000 liters 1 cubic meters is how many gallons 105 gallons 264 gallons 285 gallons 365 gallons 1 psi is equal to 6.895 kpa 9.876 kpa 3.678 kpa 7.365 kpa

36. Known as the Sanitary Engineering Law A. B. C. D. 37. RA 9275 RA 1378 RA 1364 RA 9514 Known as the Fire Code of the Philippines of 2008

A. B. C. D. 38. A. B. C. D.

RA 9275 RA 9514 RA 1368 RA 9250 The requirement of the Dry Standpipe in every 4 storey or more was stated in PD 907 PD 1093 PD 2596 PD 1025

39. A pipeline system filled with water and connected to a constant water supply for the used of the BFP for Fire Suppression purposes is A. B. C. D. 40. Dry Standpipe Wet Standpipe Combination Standpipe Standard Standpipe The minimum size of Dry Standpipe is 64mm (2 1/2") 52mm (2") 38mm (1 1/2") 102mm (4")

A. B. C. D.

41. Is a technique whereby air is blown into spaces which are designed to be kept clear smoke A. B. C. D. Aeration Pasteurization Pressurization Compressed Air

42. The pipes are normally not filled with water. Water is introduced into the system thru fire service connection is A. B. C. D. Dry Standpipe Wet Standpipe Combination Standpipe Standard Standpipe

43. The maximum travel distance of a Dry Standpipe outlet connection to any point in a building is A. B. C. D. 20 meters 30 meters 40 meters 50 meters

44. Is an auxiliary fireline system with constant water supply installed primarily for emergency use A. B. C. D. 45. A. B. C. D. 46. A. B. C. D. 47. Dry Standpipr Wet Standpipe Combination Standpipe Standard Standpipe The maximum height of a Fire Service Connection above gradeline is 460mm 1200mm 1220mm 2110mm The valve diameter must be installed in every floor for a Wet Standpipe is 32mm (1") 38mm (1 1/4") 52mm (2") 64mm (2 1/2") Standard slope of all horizontal runs of a Dry Standpipe is 5 % 10 % 15 % 20 % Minimum height of a Wet Standpipe above floor is 810mm 910mm 1100mm 2100mm The minimum pressure of the hydrostatic testing for the Dry Standpipe is 50psi (3.5kg/cm2) 60psi (4.5kg/cm2) 70psi (5.0kg/cm2) 80psi (6.5kg/cm2)

A. B. C. D. 48. A. B. C. D. 49. A. B. C. D.

50. What is the maximum Dry Standpipe design pressure to withstand water pressure when ready for service? A. B. C. D. 100psi 200psi 300psi 400psi