You are on page 1of 2

100% Supply

Air intake- frost coil - filtration - cooling - heating - supply fan

GEA CAIRplus SX Air Handling Units with maximum flexibility


Modular configuration with optimised energy efficiency
ECOROT (Rotor)
Air intake - frost coil - filtration - ECOROT- cooling - heating - supply fan // Return - filtration - ECOROT - extract fan - exhaust

ECOPLAT (Plate)
Air intake - frost coil - filtration - ECOPLAT - cooling - heating - supply fan // Return - filtration - extract fan - ECOPLAT - exhaust

GEA CAIRplus air handling units implement cooling, heating,

conditions demanded by the client, whilst still providing the

humidifying, dehumidifying, filtration and cost-effective energy

flexibility to meet the exact demands of the application.

recuperation. They are modular in design which means the units


can be configured individually to suit the application.

The units are available in a range of sizes and capacity classes.


Depending on the type, GEA CAIR units can be installed with

Various components, such as rotary heat exchangers, plate type heat

vertical or horizontal airflow, as double deck, side by side or straight

exchangers, heat pipes and liquid coupled heat exchangers are

through arrangement and are available for indoor and outdoor

available for heat recovery and partial moisture recovery and can

installation.

be selected for maximum efficiency to meet Part L Building


Regulations.

The CAIRplus range is characterised by the great diversity of


models which satisfy the most stringent quality requirements. Each

For use in new buildings and the modernisation and refurbishment

unit is individually designed using the GEA L-Plus selection

of existing facilities, GEA CAIRplus allows optimal planning and

software.

design . The aim of this range is to achieve the air volumes and air

engineering for a better world

GEA Heat Exchangers

ECOFLOW (Run around coil)


Air intake - frost coil - filtration - ECOFLOW - cooling - heating - supply fan // Return - filtration - extract fan - ECOFLOW - exhaust

Main Features AHU

100% Supply

Heat Recovery Wheel (ECOROT)

Plate Heat Exchanger (ECOPLAT)

Run Around Coil (ECOFLOW)

The following characteristics apply to all AHU on this page

Supply: Air intake, frost coil, filtration, cooling, heating,


supply fan

Supply: Air Intake, frost coil, filtration, ECOROT, cooling,


heating, supply fan

Supply: Air take, frost coil, filtration, ECOPLAT, cooling, heating, supply fan

Supply: Air intake, frost coil, filtration, ECOFLOW


cooling, heating, supply fan

Return: filtration, ECOROT, extract fan, exhaust

Return: filtration, ECOPLAT, extract fan, exhaust

Return: filtration, extract fan, ECOFLOW, exhaust

Airflow

Width

Length

Height

Weight

Type

m3/hr

m3/s

mm

mm

mm

kg

064.052IVVV

1800

0,50

760

3840

720

408

840

452

Height

Weight

max.
Overwidth*

mm

mm

kg

mm

4840

1360

811

Length

Length

Height

Weight

mm

mm

kg

1 x 200

4800

1360

1 x 240

5000

1600

Length

Height

Weight

mm

mm

kg

822

4720

1360

736

923

4680

1600

792

2240

1235

4840

2240

1021

064.064IVVV

2400

0,67

760

3960

064.096IVVV

3700

1,03

760

4000

1160

568

5000

2240

1177

1 x 440

5520

096.052IVVV

3100

0,86

1080

3960

720

510

4840

1360

936

4920

1360

1000

4800

1360

905

096.064IVVV

4000

1,11

1080

4000

840

572

5000

1600

1131

1 x 200

5160

1600

1156

4840

1600

1023

1160

724

5080

2240

1472

1 x 360

5600

2240

1534

4840

1600

901

096.096IVVV

6300

1,75

1080

4080

4920

2240

1332

128.064IVVV

5700

1,58

1400

4000

840

677

4880

1600

1252

5160

1600

1364

4840

1600

1229

128.096IVVV

8900

2,47

1400

4320

1160

891

5280

2240

1720

1 x 200

5800

2240

1834

5160

2240

1621

128.128IVVV

11700

3,25

1400

4440

1480

1062

5440

2880

2199

1 x 440

6200

2880

2241

5280

2880

2037

1160

1114

2240

2332

160.096IVVV

11400

3,17

1720

4600

5480

2240

2023

6280

5440

2240

2048

160.128IVVV

15100

4,19

1720

5040

1480

1361

6160

2880

2648

1 x 320

6720

2880

2783

5640

2880

2483

160.160IVVV

19300

5,36

1720

5440

1800

1763

6440

3520

3527

1 x 520

7240

3520

3765

5840

3520

3188

188.096IVVV

13700

3,81

2000

4840

1160

1251

5840

2400

2500

6240

2400

2798

5440

2400

2396

1480

1555

3040

3978

5640

3040

2932

3680

4609

6160

3680

3751

6160

4240

4279

188.128IVVV

18000

5,00

2000

5240

6360

3040

3346

1 x 200

7400

188.160IVVV

22600

6,28

2000

5560

1800

1945

6840

3680

4216

1 x 400

7800

188.188IVVV

27500

7,64

2000

5560

2080

2184

7000

4240

4860

1 x 600

220.128IVVV

21500

5,97

2320

5280

1480

1851

6280

3040

3583

7040

3040

4066

5880

3040

3490

7800

3680

5007

220.160IVVV

26800

7,44

2320

5560

1800

2165

7240

3680

4368

1 x 280

6160

3680

3886

220.188IVVV

32000

8,89

2320

5760

2080

2465

7320

4240

5495

1 x 600

6360

4240

5229

220.220IVVV

37800

10,50

2320

6120

2400

3034

7600

4880

6391

2 x 400

6360

4880

5647

252.128IVVV

24500

6,81

2640

5280

1480

2002

6200

3040

3984

5880

3040

3923

6360

4240

5636

7040

3040

4497

252.188IVVV

37100

10,31

2640

6120

2080

3026

7600

4240

6250

1 x 480

280.160IVVV

34900

9,69

2920

5760

1800

2569

7320

3680

5623

1 x 200

6360

3680

5119

280.188IVVV

41500

11,53

2920

6120

2080

3211

7960

4240

6998

1 x 320

6720

4240

6407

280.220IVVV

49000

13,61

2920

6240

2400

3613

7720

4880

7356

1 x 600

6840

4880

7036

280.252IVVV

55000

15,28

2920

6040

2720

3801

280.280IVVV

58000

16,11

2920

6760

3000

5058

312.188IVVV

46800

13,00

3240

6160

2080

3423

7840

4240

7251

1 x 200

6760

4240

6871

312.220IVVV

54300

15,08

3240

6240

2400

3819

7720

4880

7831

1 x 440

6480

4880

7110

312.252IVVV

61700

17,14

3240

6040

2720

4136

312.280IVVV

65000

18,06

3240

7000

3000

5794

312.312IVVV

73400

20,39

3240

6880

3320

6170

Information on Request

* AHU maximum overwidth is dependent on the


efficiency of the heat recovery wheel

8000

3680

5912

Generally in accordance with Part L Building Regulations 2010 for central mechanical ventilation system including heating & cooling, together with heat recovery Casing characteristics in accordance with EN1886
Enclosure panels - 60mm wall thickness, double skinned - indoor and outdoor installation The specifications contained in this brochure are intended only to serve as a non-binding description of our products and services and
are not subject to guarantee Binding specifications, especially pertaining to performance data and suitability for specific operating purposes, are dependant upon the individual circumstances at the operation location and
can, therefore, only be made in terms of precise requests
Cooling coil selected 6 / 12C LPHW coils 80 / 60C Fan external static 250 Pa

GEA Denco Systems. Subject to modifications. 05/2013 PR-2011-1000-EN

GEA CAIRplus SX: Specifications