3 to 17.5 kV
General contents
Withdrawable circuit-breakers 17.5 kV and technical features RI operating mechanism and auxiliary diagram
Measuring transformers
Busbar compartment
10
Control compartment
11
12
14
15
Schneider Electric
Metal-clad substations
The Fluair panels are made up of factory-built metal enclosures of the metal-clad type in accordance with IEC international standards. These panels comprise 4 fully self-contained compartments: s a switchgear compartment, s a cable connection compartment, s a busbar compartment, s a control gear compartment. All the metal frames are permanently connected together electrically.
Interlocks
Operating safety is enhanced by a series of interlocks designed to: s prevent incorrect operation, s prevent direct access to current-carrying parts, s restrict access to the network control equipment.
Degree of protection
IP 3X or IP 5X to IEC 529 (a higher level of protection can be provided on request).
Surface treatment
All the metal surfaces in the panels are treated against corrosion: s the outside panels are protected by galvanisation and with an epoxy polyester coating standard colour RAL 1011 or RAL 7030, and have been put through the surface tests laid down in standards IEC 68-2-11. s the internal partitions are protected against corrosion by galvanisation, with chrome passivation.
Rigorous testing
The Fluair panels have successfully undergone the type approval tests set down in the IEC international standards, including: s dielectric tests, s temperature-rise tests, s mechanical endurance tests, s short time withstand current and peak withstand current tests. In addition to these standardised tests, the requirements for other types of installation can also be met. For example: s resistance to humid conditions, s resistance to internal arcing (in accrodance to IEC international standards).
40
1000 750 500 Fluair 100 Fluair 200 350 250 17.5 Ua (kV) rated voltage
14.5
7.2
12
Schneider Electric
The circuit-breaker compartment is totally enclosed by metal walls. It houses a withdrawable unit which can take up 3 positions:
s in service : unit latched in the plugged-in position, s isolated : unit latched in unplugged or test position, with fully visible isolation
achieved by disconnection of the moving portion from the fixed portion and closing of the shutters, s withdrawn : unit outside the panel.
Fixed portion
The fixed portion is equipped with all the devices necessary for the withdrawable unit to be connected and disconnected in total safety:
s bushing, electrical insulating and containing built-in fixed contacts, s sliding metallic shutters, can be fitted with padlocks, and which automatically blank off the fixed contacts; the shutters can be manually operated to inject a signal to search for faults on cables, s bolted-on panels, which can be removed at the front in order to access the busbar set and the current transformers secondary, s an arrangement, to maintain the continuity to earth while the unit is being pulled out or inserted, s an insertion disabling interlock which can be padlocked (padlock not supplied), automatically preventing the insertion of the withdrawable unit if the earthing switch is closed, s safety interlock to prevent closure of the earthing switch if the unit is in the in service position, s a multi-contact connector, used to connect auxiliary circuits.
Circuit-breaker panel
positions,
s voltage on indicator lamps, s an earthing switch: the position of this switchs flags is clearly visible from
the front and indicated from the rear of the panel (see also cable connection compartment), s padlocks: 4 padlocks can be fitted for the earthing switch and 2 for the circuit-breaker (withdrawn position), s a foolproofing interlock, which only allows withdrawable units appropriate to the panel to be inserted into the panel, s a front door, the addition of which creates extra space, which can then take the withdrawable unit in the isolated door closed position, giving the IP5X degree of protection (steps are taken to maintain alignment of front panels).
Schneider Electric
Circuit-breaker range
Circuit-breaker ranges are used in 7.2 to 17.5 kV cubicles. Breaker operation is based on SF6 technology. The circuit-breaker is of the sealed pressure system type. The gas-tight enclosure is filled with SF6 at a low gauge pressure of 0.15 MPa (1.5 bar). A pressure switch with a NO contact for continuous monitoring of the SF6. Low pressure filling guarantees reliable gas-tightness. Circuit-breaker ranges are actuated by RI type spring stored energy operating mechanisms.
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Schneider Electric
LF3 circuit-breaker
IEC 56 rated voltage insulation level rated current (Ia) kV, 50/60 Hz kV, rms 50 Hz - 1 mn kV, impact 1.2/50 s A 1250 2500 3150 breaking capacity Isc making capacity capacitor breaking capacity rated switching sequence kA, rms kA, peak A O-3 mn - CO-3 mn - CO O-0.3 s - CO-15 s - CO O-0.3 s - CO-3 mn - CO operating times ms opening breaking closing s s 25 63 25 440 s s s 48 70 65 s s 31.5 79 31.5 s s 40 100 40 s s 50 125 50 s s 25 63 25 440 s s s 48 70 65 s s 31.5 79 31.5 s s 40 100 40 LF3 7.2 20 60 12 28 75 s s s 50 125 50 s s 25 63 25 440 s s s 48 70 65 s s 31.5 79 31.5 17.5 38 95
Schneider Electric
mechanism as soon as the contacts close (time 5 s), two mechanical push buttons on the front panel for opening and closing, an electrical closing system including: a closing release for remote control and an anti-pumping relay. an electrical opening release system featuring one or more releases of the following types: shunt, undervoltage, low power-consuming mitop (1), s operation counter, s an optional operating mechanism charged indication contact, s an end-of-charging contact, s a black and white mechanical open closed position indicator, s a multi-pin connector for isolating auxiliary circuits in the disconnected position.
Auxiliary contacts
The RI operating mechanism is equipped with a block of 14 auxiliary contacts, including: s 1 changeover contact for the electrical operating mechanism, s 1 changeover contact for indication, s 1 contact for the shunt release. The number of available contacts depends on the composition of the operating mechanism and the options chosen, (see the table below).
RI operating mechanism
LF range circuit breakers are actuated by an RI operating mechanism that ensures switching device closing and opening speed that is independent of the operator. Circuit breakers equipped with an RI electrical operating mechanism can perform remote control functions and implement reclosing cycles.
AC DC
(1) mitop: very low power consuming release used as option with Sepam 100 LA, back-up protection supplied by CT secondaries only.
supply voltage
AC (V) 50 Hz DC (V) consumption AC (VA) DC (W) possible combinations = s1 of auxiliaries and quantities or or or or or or or or or or
(2) consumption pick-up/hold.
48 - 110 - 125 - 220 24 - 30 - 48 - 60 - 110 - 125 - 220 380 300 300 380 180 100 + + + s1 s1 s1 s1 s1 s1 s1 s1 s1 s1 s1 s1 s1 s1 s1 s1 s1 s1 s1 s1 s1 s1 s1 s1 s1
450 150 + s1
(2)
s1 s1
s1 s1 s1
s1 s1
s1 s1 s1
6 6 6 6 6 6 6 6 6 4 6
1 6 6 7 6 6 7 7 5 5 5
1 1 1 1 1 1 1 1 1
Schneider Electric
Fluair cubicle IP 3X
Fluair cubicle IP 5X
Schneider Electric
The cable connection compartment, which is accessed from the rear of the panel, is entirely enclosed by metal walls. This compartment contains:
s gland plates, fitted out to receive single-core or three-core dry-insulated cables with synthetic cable terminations, s non-magnetic cable supports to prevent external
the metal frames of the different panels so that they can be earthed,
s measuring transformers (see facing page).
Cable connection is made simple by the clearance left between the floor and gland plates and the large amount of space left free within the compartment.
Circuit-breaker panel
Options
The following optional accessories are available:
s 3 voltage capacitive dividers, incorporated into the insulators which support the
terminal plates, and connected to 3 neon indicators mounted on the front plate, to indicate whether the cables are live or dead,
s an earthing switch, used to earth and short-circuit the cable ends before work is
request.
Schneider Electric
The active components of the dry-insulation measuring transformers (current and voltage transformers) are sealed in an insulating resin. They supply power to the current and voltage circuits of the measurement and/or protection devices. These compact transformers have very good electrical and mechanical characteristics.
Current transformers
Current transformers are accomodated inside cable connection compartment and come in 3 types .
s conventional type, with 1, 2 or 3 5 A secondary windings (1 A as an option). s air core current sensor (CSP), non-saturating, with linear response and broad dynamic range. s core balance type (CSH), provides more sensitive protection by direct measurement of earth fault current.
Measuring transformers in a circuit-breaker panel, showing optional functional voltage transformer with fuse
Voltage transformers
As a standard, voltage transformers are of the fixed type (fixed fuse can be supplied as an option). Functional voltage transformers can be supplied as an option. They are protected by a built-in fuse, and can be operated simultaneously from the rear of the panel without interruption to the busbar. When the functional voltage transformers are in the isolated position, the replacement of a fuse can be performed using a padlockable shutter.
10
Schneider Electric
The busbar compartment forms a distribution trunking enclosed by metal partition walls. The system of busbars is thus totally safe, since no moving parts are inside the compartment.
Single-busbar panels
In single-busbar panels, this compartment contains bare plate copper busbars bolted onto the supports (insulated bars optional).
Busbar compartment
Double-busbar panels
Circuit-breaker double-busbar panels are used when two separate power supply circuits are used to ensure continuity of service. Each busbar system is housed in an independent compartment. The two compartments contain bare plate copper busbars, bolted onto the supports (insulated bars optional). In the incoming or outgoing panels, the circuitbreaker is connected to 2 branching isolators which connect it to either one or other of the 2 busbar sets. The isolators can be operated mechanically using a lever located on the rear panel. The branching isolators can be interlocked mechanically by a key system. As an option, each isolator can be fitted with: s electrical control, s an electrical interlock system.
Schneider Electric
11
The control compartment which is located at the front of the Fluair panel, is also separated from the other compartments by metal partition walls. This compartment contains all the protection and control units required to perform protection, automation and measurement functions.
Sepam 2000
Sepam range
Sepam replaces measuring instruments such as ammeters, voltmeters, watt meters, power meters, etc. It displays alarm and operating messages in association with the protection functions and control logic, which eliminates the need for indicator lamps. The front panel includes: s light-up alphanumeric display that is simple and legible from several meters away.
s keys used to select the measurements to be
displayed and acknowledge messages. As a security measure, these keys do not provide access to the protection settings.
s a dedicated door providing access to: the outlet for connection of the TSM 2001 pocket
setting terminal, the housing for the cartridge that contains the different application programs needed for Sepam operation.
Circuit monitor
0 of SF 51n Io>> ex t 6 f I on
Power meter
2A 16 A = 1 I1 16 A = 63 I2 1 = I3 2% = r clea HD
Sepam 1000
12
MERLIN GERIN
rese
A TSM 2001 pocket terminal is used to set Sepam parameters and make adjustments. The pocket terminal, equipped with a keyboard and a display unit with four 20character lines, has an operating system that comprises user-friendly menus. The terminal may also be used to look up maintenance information such as fault current value, number of breaker operations, sum of breaking kA, etc As a security measure, access to Sepam parameters is protected by a password.
Schneider Electric
Basic functions
The main functions are:
s installation display by chained mimic diagrams (animated single-line diagram,
Modular design
The software unit capacity and functionality may be scaled in accordance with the size of the switchboard. This also provides the option of starting with a small set of monitoring and control equipment, and then completing it later on, by adding a substation or electrical network monitoring and control system.
Disturbance recording
Architecture
The user terminal consists of a compatible personal computer. It is directly connected to the Sepam protection units via a standard communication bus. The control station may easily be connected to a higher level monitoring and control system via Ethernet.
Schneider Electric
13
PowerLogic system
The PowerLogic system integrates all the intelligent components of the electrical network, using standard communications and powerful software. This gives you the tools you need to manage the cost and quality of power.
Harmonic analysis is available any time you need it, with simultaneous capture of current and voltage waveforms, plus summary information. With a record of each voltage sag, you can diagnose problems and prevent future downtime.
your intranet or the Internet, s scaleable system architecture lets you start small and add devices and upgrade your system as you want.
technical support, s broad range of components can be installed on existing equipment by any manufacturer, s field-upgradeable products and periodic software upgrades ensure the system will continue to meet new or changing needs.
14
Schneider Electric
Standard panel
Buscoupler panel
Busriser panel
15
Dimensions
panel type rated current (A) 1600 3150 coupling busriser 1600 3150 1600 3150 dimensions (mm) H W (4) 2100 650 2100 650 2100 900 2100 900 2100 650 2100 900 2100 650 2100 900
360 500
incoming or outgoing
Approximate weight
panel type rated current (A) 1600 3150 1600 3150 approximate weight (kg) 600 720 380 430
1110 500 D
260(2)
817(3) 1400
12
17.5
3-core 2 4 3 2 4 3 2 4 3
1476
351
Auxiliary circuits
The auxiliary conductors can be led out to the outside via: s the ground, underneath each panel or at the end of the switchboard. s overhead, at the rear of each panel.
0 0
2190
1945
1455
(1) The circuit-breaker panels are designed to be fitted with single-core (max outside diameter 60 mm) or three-core (max outside diameter 95 mm) dry-insulated power cables. Cables insulated with impregnated paper can also be used, (please consult us for details). (2) Isolated position. (3) withdrawn position. (4) all dimensions are given for indication only. Exact dimensions depend on configurations, (please consult us for details).
16
0 65 150
Schneider Electric
Schneider Electric
17
68,Tayaran st, Nasr City, Cairo, Egypt P.O. Box 2658 El Horreya tel : (202) 40 10 119 Fax: (202) 26 18 908 http://www.schneider.com.eg
As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication.
Design, production & publishing: Communication - Schneider Egypt Printing: Trust Advertising Co.
SEE 05031 / E