Natural Air Ventilator System As Exhaust Systems Naturalairvent India ***************************** Introduction A good and effective Natural Air

ventilation system is necessary in a workplace which have processes that air contaminants such as dust, fumes, mists or vapours . Substitution or enclosure method Simple, cheap and effective ************************************ Type of Ventilation Natural Air Ventilation ************************** Natural Ventilation Natural movement of air entering and leaving openings such as windows, doors, ro of top ventilators as well as through cracks and crevices of a building Heated air rises, cool air below ****************** Buildings and ventilating equipment should not usually be oriented for a particu lar wind direction. Air ventiation openings should not be obstructed by buildings , trees, signboar ds, or indoor partitions. For temperature difference to produce a motive force, there must be vertical dis tance between openings; vertical distance should be as great as possible. Openings in the vicinity of the nautral air pressure level are least effective f or ventilation. Openings with areas much larger than calculated are sometimes desirable. **************************** Wind Driven Turbo Ventilators Shell and exterior air barriers Interior barriers to flow that cause internal pressure buildup and thus reduce i nfiltration. Lack of precise knowledge of the detailed wind pressure profiles on building sur faces. Influence of complex terrain, presence of trees and other obstacles that create channeling and may increase the magnitude of wind force and alter its direction close to the structure. *************************************** Fan Pressurization It is sometimes also called depressurization. It is not a direct measure of infiltration. It characterizes the building leakage rate independent of weather conditions. Measurements are made by using a large fan to create an incremental static press ure difference between the interior and the exterior of the building. The air leakage rate is determined by the relationship between the airflow rates and pressure differences.

***************************************** Advantages and Disadvantages of Fan Pressurization It es It ve It does not require sophisticated analytical equipment as do the tracer techniqu allows for a comparison of homes based on their relative leakiness irrespecti of the prevailing weather conditions at the time of measurement can be used to measure the effectiveness of retrofit measures

Disadvantages: This is an indirect measure of infiltration and hence approximates the actual pr ocess through an inherently artificial process, pressurization or depressurizati on General Ventilation A method of improving or maintaining the quality of air in the work environment with airflow Building is flushed by supplying and exhausting large volumes of air throughout the area Air Ventilator Manufacturers Roof Top Exhaust Systems Industrial Ventilators ***************************

You might also like