You are on page 1of 8

Fanuc 6 Alarm Codes, System Fanuc 6 alarms

Fanuc System 6M and 6T Alarm codes, 210 to 245 Errors on stroke end limit switches 400 to 445 Errors on Servo System 600 to 603 Errors on PCB or Cables 700 to 702 Overheat of section or motor 900 to 999 Errors on Memory

Fanuc 6 Alarms Program errors or Operator's Error 000 Re-apply the power after the parameter has been input 001 TH Alarm (A character with incorrect parity was input) Correct the tape 002 TV Alarm (The number of characters in a block is odd). This alarm will be generated only when the TV check is effective 003 Data exceeding the maximum allowable number of digits was input 004 A numeral or the sign (-) was input without an address at the beginning of the block 005 The address was not followed by the appropriate data but was followed by another address of EOB code 006 Sign "-" input error (sign "-" was input after a address with which it can't be used. Or two "-" signs were used). 007 Decimal Point "." Input error (A decimal point was input after a address with which it can't be used. Or two decimal points were input). 008 The switch position of the tape reader was not AUTO (without reel) or REEL ON/REEL OFF (with reels). 009 Unusable character was input. (E). 010 A unusable G code was commanded. (The alarm is generated also when a G code with which the control is not equipped as an option is commanded). 011 Feedrate was not commanded at cutting feed or the feedrate was inadequate 015 The number of the commanded axes exceeded that of the allowable simultaneously controlled axis 017 The move commanded of the additional axis was commanded without equipping with an optional additional axis. 018 An additional axis was commanded with the other axis simultaneously. 021 The axis not included in the selected plane (by using G17, G18, G19) was commanded in circular interpolation.

022 In circular interpolation, radius designation was performed in the NC which is not equipped with the radius designation option. 023 In circular interpolation by radius designation, Zero was commanded for address R. 030 The tool offset number is too large for the D or H function. 031 In setting of offset amount by G10, The offset number following address P was excessive or it was not specified. 032 In setting of offset amount by G10, the offset amount was excessive. 035 Skip Cutting (G31) was commanded in cutter compensation mode. 036 G45-G48 (Tool Offset) was commanded in cutter compensation mode. 037 The selected (by using G17, G18 or G19) changed in cutter compensation mode. 038 Over cutting will occur in cutter compensation because the arc start point or end point coincides with arc center 041 Overcutting will occur in cutter compensation. 044 One of G27-G30 was commanded in canned cycle mode. An ATC cycle (M06) was commanded in canned cycle mode. 045 An ATC cycle (M06) was commanded for the NC which is not equipped with optional reference point return feature. 046 Other than P2, P3 and P4 was specified in the 2nd, 3rd and 4th reference point return commands. 047 G27 to G30 was commanded for and axis which does not have a reference point. 058 In 4-digit S code binary 12-bit/analogue output A, A command was specified exceeding the maximum or minimum number of spindle revolutions. 059 No program for selected work number is found (external work number select A function). 060 Commanded sequence number was not found in the sequence number search, 065 Scaling Magnification was specified as other than 1-99999. 066 Scaling was applied and as a result, movement value, coordinate value, circular arc radius, etc. exceed maximum programmable dimension. 067 G51 (scaling ON) was specified in cutter compensation mode. 070 The Fanuc memory area is insufficient. 071 The address to be searched was not found. 072 The number of programs to be stored exceeds 95 or 191. (191 is a option(. 073 The program number has already been used. 074

The program number is other then 1-9999 075 The program number or sequence number was not found at the start block of the program 076 The address P was commanded in the block with includes a M98 command. 077 The subprogram was called in triple 078 The sequence number which was specified by address P in the block which includes a M98 or M99 was not found 079 Memorized program and tape contents do not coincide 085 When storing data in memory by using ASR or RS232C interface, an over-run or framing error was generated 086 The signal level of RS232C interface was incorrect 087 When storing data in the memory by using the Fanuc RS232 interface, the time required to store the data is insufficient. 090 The reference point return cannot be performed normally because the reference point return start point is to close to the reference point or one revolution signal is not input owing to a fault in the pulse coder. 091 Reference point return cannot be executed normally, because of the feedrate is too low to synchronise the one revolution signal of the pulse coder with the reference counter, 092 The axis designated by G27 did not return to reference point. 094 No P type can be specified for program restart (because after program interruption, coordinate system setting or ORIGIN, etc. was executed) 095 No P type can be specified for program restart (because after program interruption, external work zero point offset value changed) 096 No P type can be specified for program restart (because after program interruption, work zero point offset value changed). 097 No P type can be specified for program restart (because after program interruption, no automatic operation has been executed). 100 The switch to set parameters is on. Push the reset button after turning off the switch. 101 The power was turned off while rewriting the contents of memory in the part program storage & editing operation. When this alarm is generated you must turn on the power while pushing the DELETE and RESET buttons to clear the memory. 110 Absolute value of data of fixed point representation exceeds the upper bound (99999999). 111 Exponent of data of floating point representation exceeds the upper bound. 112 Divisor is 0 113 A function that cannot be used by user macro A is used

114 Format error except for 115 Value not defined as variable number is assigned 116 Left side of substituted sentence is a variable of prohibited substitution 118 Nesting of brackets exceeds the upper limit (5). 119 Argument of SQRT is negative , Or argument of BCD is negative 122 Nesting of macro exceeds the upper limit (4) 123 Macro control command is uded in tape mode 124 DO END is not 1:1 corresponding 125 Format error of (formula) 126 Not 1 n 3 in DO n 127 NC command and macro command are mixed 128 Not 0 n 9999 in GO TO n 129 Unallowable address is used in . 130 In external data input, greater-address data contains an error 131 In external alarm message, five or more alarms have occurred 132 In external alarm message, clear, no corresponding alarm number exsists 133 In external alarm message and in external operator message, smaller- address data contains an error 170 Programs of numbers 8000 8999 and 9000 9899 are being edited, But this alarm occurs only when parameter setting inhibits these programs to be edited. Error on Stroke Limit Switch 210 The movable part of machine touched the X Axis plus stroke limit switch 211 The movable part of machine touched the X Axis minus stroke limit switch 212 While the X Axis was moving in the plus direction, It entered into the forbidden area of the stored stroke limit 1 213 While the X Axis was moving in the minus direction, It entered into the forbidden area of the stored stroke limit 1 214 While the X Axis was moving in the plus direction, It entered into the forbidden area of the stored stroke limit 2 215 While the X Axis was moving in the minus direction, It entered into the forbidden area of the stored stroke limit 2 220 The movable part of the machine touched the Y axis plus stroke limit switch

221 The movable part of the machine touched the Y axis minus stroke limit switch. 222 While the Y axis was moving in the plus direction, it entered into the forbidden area of the stored stroke limit 1 223 While the Y axis was moving in the minus direction, it entered into the forbidden area of the stored stroke limit 1 224 While the Y axis was moving in the plus direction, it entered into the forbidden area of the stored stroke limit 2 225 While the Y axis was moving in the minus direction, it entered into the forbidden area of the stored stroke limit 2 230 The movable part of the machine touched the Z axis plus stroke limit switch 231 The movable part of the machine touched the Z axis minus stroke limit switch 232 While the Z axis was moving in the plus direction, it entered into the forbidden area of the stored stroke limit 1 233 While the Z axis was moving in the minus direction, it entered into the forbidden area of the stored stroke limit 1 234 While the Z axis was moving in the plus direction, it entered into the forbidden area of the stored stroke limit 2 235 While the Z axis was moving in the minus direction, it entered into the forbidden area of the stored stroke limit 2 240 The movable part of the machine touched the 4th axis plus stroke limit switch 241 The movable part of the machine touched the 4th axis minus stroke limit switch Error on servo system 400 The control received the X, Y or Z axis overload signal 401 The READY signal (VRDY) of the X, Y or Z axis velocity control has turned off 402 The control received the 4TH axis overload signal 403 The READY signal (VARY) of the 4TH axis velocity control has turned off 404 The READY signal (VARY) of the X, Y or Z axis velocity control does not turn off even though the READY signal (PRDY) of the position control has turned off The READY signal (VARY) of velocity control already on even though the READY signal (PRDY) of the position control is off yet at power on condition 405 In reference point return, reference point return is not performed in correctly by abnormality of NC control section or servo system. Perform manual reference point return again 410 The content of error register of the X axis is larger than the value allowed while the machine is stopped 411

The content of error register of the Y axis is larger than the value allowed while the machine is moving 412 Drift in X axis is excessive. (Exceeds 500VELO) 413 The content of the error register of the X axis exceeded =32767. Or the velocity command value of the DA converter is out of the range of +8191~ - 8192. Incorrect settings will cause this alarm 414 The resolver/inductosyn position detecting system of X axis is trouble 415 A feed rate exceeding 511875 detection units/sec was commanded in the X axis An incorrect setting of CMR causes this error 416 X axis pulse coder position feedback is abnormal. (Disconnection alarm) 420 The content of the error register of the Y axis is larger than the value allowed while the machine is stopped 421 The content of the error register of the Y axis is larger than the value allowed while the machine is moving 422 Drift in Y axis is excessive. (Exceeds 500VELO) 423 The content of the error register of the Y axis exceeded =32767. Or the velocity command value of the DA converter is out of the range of +8191~ - 8192. Incorrect settings will cause this alarm 424 The DSCG position detecting system of the Y axis is trouble 425 A feed rate exceeding 511875 detection units/sec was commanded in the Y axis An incorrect setting of CMR causes this error 426 Y axis Fanuc pulse coder position feedback is abnormal. (Disconnection alarm) 430 The content of the error register of the Z axis is larger than the value allowed while the machine is stopped 431 The content of the error register of the Z axis is larger than the value allowed while the machine is moving 432 Drift in Z axis is excessive. (Exceeds 500VELO) 433 The content of the error register of the Z axis exceeded =32767. Or the velocity command value of the DA converter is out of the range of +8191~ - 8192. Incorrect settings will cause this alarm 434 The resolver/inductosyn position detecting system of Z axis is trouble 435 A feed rate exceeding 511875 detection units/sec was commanded in the Z axis An incorrect setting of CMR causes this error 436 Z axis pulse coder position feedback is abnormal. (Disconnection alarm) 440 The content of the error register of the 4TH axis is larger than the value allowed while the machine is stopped 441

The content of the error register of the 4TH axis is larger than the value allowed while the machine is moving 442 Drift in 4TH axis is excessive. (Exceeds 500VELO) 443 The content of the error register of the 4THaxis exceeded =32767. Or the velocity command value of the DA converter is out of the range of +8191~ - 8192. Incorrect settings will cause this alarm 444 The resolver/inductosyn position detecting system of the 4TH axis is trouble 425 A feed rate exceeding 511875 detection units/sec was commanded in the 4 TH axis An incorrect setting of CMR causes this error 426 Additional axis pulse coder position feedback is abnormal. (Disconnection alarm) Connection alarm between each PCB 600 Data transferring error took place in the connection unit or in PC-model C 601 Slave relay was turned off. (Connections among unit, MDI/DPL (MDI/CRT) and master PCB are trouble. Another case change connection unit) 602 PC program has not yet been loaded 603 The correspondence between NC and PC is incorrect or interrupted. Change power sequence control PCB or master PCB 604 No hold is effective to PC-model B side MPU 605 A system error has occurred in PC-model B side MPU 606 RAM/ROM parity has occurred in PC-model B side MPU 607 Data transferring error took place in Fanuc MDI & CRT Overheat alarm 700 Overheat of the master PCB 701 Overheat of the PCB for 4TH axis 702 Overheat of DC motor for X, Y, Z axis 703 Overheat of DC motor for 4TH axis Errors on memory 900 Fault in bubble device. (Fault of input signal for bubble device) 901 Fault in bubble device. (The initial point in the bubble was not detected immediately after power on) 902 Fault in bubble device. (Page size error, undefined command) 903 Fault in bubble device. (Transfer missing, page size over) 904 Fault in Fanuc bubble device. (Parity error) 905 Fault in bubble device. (No marker)

906 Fault in bubble device. (Many defect loops) 910 RAM parity error (low byte) 911 RAM parity error (high byte) 920 System error (watch dog timer alarm) 930 CPU error (0, 3, 4 type interrupt generation) 997 ROM parity error (PC ROM) 998 ROM parity error (Basic ROM) 999 ROM pair error (No correspondence between high and low)

You might also like