Though it began manufacturing operations in 1866, Campbell first made its lightweight, rugged plate lifting clamp in 1938. It was designed by an Englishman named Volz. Because it incorporated forged parts of heat treated, alloy steel, the Campbell clamp earned a worldwide reputation for reliability and long life. It is widely used by steel mills, warehouses and fabricating shops and is much preferred because its forged parts give increased strength yet are lightweight. And, they are readily available when servicing is required.
Contents Clamps, Chain Connector Clamps, Drag Clamps, GX Clamps, GXL Clamps, Horizontal Plate Clamps, Locking E Clamps, Non-Marring Clamps, Rubber Pad Clamps, SAC (Screw-Adjusted Cam) Clamps, Sharp Leg Clamps, Short Leg Structural Connector, Chain Drum Deheader Drum Lifter, Fork Truck Drum Lifter, Single Drum Lifter, Twin Grip, Duplex Hand Inspection of Clamps Slings, Drum Warning Statement
The Campbell operation facilities in York, PA, and Cortland, NY, conform to Quality Standard ISO 9001.
Click
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
LIFTING CLAMPS
WARNING
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Do not exceed Working Load Limit stamped on Clamp body. Inspect clamp before each lift. Stand clear of load when lifting. Position clamp to balance load. Insert plate or unit to full depth of throat opening. Lift slowly and smoothly. Do not jerk load. Do not lift more than one plate or sheet at a time. Do not use a damaged clamp. Read manufacturers instructions before using clamps. Do not use any Campbell clamp to lift tapered plates or beams. 11. When lifting plates with a hardness over 43 Rockwell C/400 BRINELL, consult the clamp manufacturer. 12. Campbell clamps are designed to be used at temperatures between 0F and 200F.
Inspection Procedure
1. CamsThese are the parts likely to receive most wear. The amount of wear, of course, bears a direct relationship to the use the cam receives. Continued usage of plates of the same thickness will result in wear in only one area of the working surface of the cam, and will eventually require that the cam be replaced. The harder the plate is, the sooner the cam will be worn. A simple visual inspection of the cam is all that is required in most cases. The surfaces of the cam should be compared with unused surfaces. If teeth appear to be worn, the cam should be replaced. Note: The Pad and Cam should be replaced at the same time. 2. PadsThe pads of GX and E clamps are held in with a bolt and can be replaced simply by removing the bolt. When the serrations of the pad seat are worn, the pad should be replaced. Note: The Pad and Cam should be replaced at the same time. 3. Spread JawCheck the throat width of the clamp. At zero grip, the cam should be in full contact with the pad. If the width at the base (where the pad is located) is greater than the width at the top, the clamp has been overloaded and should be replaced. Warning: Do not weld on the clamp body, as this may destroy the original heat treatment. 4. Linkage and Shackle InspectionTo remove the linkage from a GX clamp, remove the load pins from the body. The pins do not rotate, and under normal load do not require replacement. They should be inspected for bending, which is caused by overloads, and replaced as needed. Inspect the shackle for bending at the rivet, which is an indication of side pull. If this is a recurrent fault, use a chain connector on the clamp. 5. Rivet InspectionRivets may require replacement when a very loose connection is detected. Linkage should normally be free working. Should a rivet hole in the shackle, radius link or connecting link become stretched or enlarged (usually resulting from overloading), those parts should be replaced. It is advisable to replace the rivet as well. To replace any worn parts, drive rivets out over a relief opening, such as a small section of pipe or the opening in a vise. Warning: Do not weld or substitute bolts for rivets. Check connecting links to ascertain that they are not bent. 6. Spring inspectionThe spring should be of sufficient strength to hold the cam against the pad. If it is not, the spring should be replaced. In the case of the E clamp, the spring should be replaced if it fails to provide initial pressure at near zero grip. 7. ChainsChains supplied with clamps should also be inspected carefully. To do this, use a Campbell wear gauge. Inspect chains link by link, checking for distorted, stretched or cracked links, nicks or gouges, pitted links and excessive wear of bearing surfaces and barrels.
ADVERTENCIA
Las mordazas en este catlogo no fueron diseadas para ser utilizadas como conexin permanente de una placa o de otros objetos. El agarre depende de la friccin y de la presin entre ambas piezas. Si no se les da mantenimiento adecuado a las superficies de agarre y se utiliza la mordaza de manera inadecuada se puede caer la carga. Tenga mucha precaucin cuando se va a elevar carga por encima de objetos o donde una falla puede ocasionar daos a la propiedad o lesiones personales. Lea los instructivos de uso y de mantenimiento.
WARNING
The clamps in this catalog are not intended to serve as a permanent connection to a plate or other object. The grip depends on friction and a camming action. If the gripping surfaces are not properly maintained and the clamp is improperly used, the load may fall. Use extreme caution where overhead lifting is involved or where a failure could cause property damage or personal injury. Read maintenance materials and use instructions.
LIFTING CLAMPS
GXL Clamps
Available in a 1/2, 1, 2, and 3 ton capacity Drop forged and heat treated components, with gripping surfaces of case hardened alloy steel Exclusive feature is a patented wear indicator system. When any of cams straight line, convex teeth are flattened between unique wear indicator grooves, it is time to change the cam Note: The Pad and Cam should be replaced at the same time Newly designed Cam Engaging Lever keeps the cam in contact with the plate. The tension arm and spring mechanism facilitate attaching and removing the clamp. These clamps will not lift plate when in the lever open position Clamps are 100% Proof Tested and Certificate of Test supplied with each clamp Warning: Never tamper with a clamps tension arm and spring mechanism during a lift
NORMAL
WORN
16 - 8 1 16 - 34 1 16 - 78 1 16 - 1
5
2 - 16 2 - 19 2 - 23 2 - 25
1 2 3
Cat. No.
B in. 10 mm 254
1 1
C in. 2
1
D mm in.
Dimensions E mm in. mm 67 78 84 98 2 2 2 3
1 1
F in. 4 5 4 7
7 1
H mm 30 41 41 46 in.
16 151
167 184 122
16 7 4 3 8 4
4 12 8 5 14 8
11
8 54 3 16 97 9 2 16 65 1 3 4 82
13
8 3 16 5 3 16 7 3 8
2
5 1
51
16 4
52 57 76
8 2
124 190
4 3 8 1 3 2
3
1 5
16 1 8 5 1 8 13 1 16
1
3 5
16 5 8 15 5 16 1 7 8
5
3 7
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
LIFTING CLAMPS
Capacity Part Name Shackle Radius Link T-Spring Conn. Link Cam Pad Cam Kit Pivot Lever E-Spring * Cam and Radius Link Pin * Pad Pin Rivets Cat. No. 6501005 6504002 6501016 6501007 6504001 6501017 6505030 6504005 6504106 6504008 6501003 ** 6501008
Qty. 1 1 1 2 1 1 1 1 1 1 3 3
Cat. No. 6501105 6504102 6501116 6501107 6501201 6501117 6505021 6504105 6504106 6504108 6501103 6501104 6501108
1TON UPC No. 020418 170805 186783 170836 170812 170850 170843 179037 186790 186806 186813 170782 170799 170829
Qty. 1 1 1 2 1 1 1 1 1 1 2 1 3
Cat. No. 6501205 6504202 6501216 6501207 6501210 6501217 6505029 6504205 6504106 6504208 6501203 6501204 6501208
2 TON UPC No. 020418 186226 186264 186233 186257 186271 186288 186202 186219 186240
Qty. 1 1 1 2 1 1 1 1 1 1 2 1 3
Cat. No. 6501305 6504302 6501316 6501307 6501301 6501317 6505022 6504305 6504306 6504308 6501303 6501304 6501308
3 TON UPC No. 020418 170904 187896 170935 170911 170867 170942 179044 187902 187919 187926 170881 170898 170928
Qty. 1 1 1 2 1 1 1 1 1 1 2 1 3
* Drive pins included. ** The swivel pad pin on this model is the same as the cam and radius link pin.
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
LIFTING CLAMPS
GX Clamps
GX clamp is entirely drop forged and heat treated Can be used for both vertical and horizontal-to-vertical lifting Exclusive feature is a patented wear indicator system. When any of cams straight line, convex teeth are flattened between unique wear indicator grooves, it is time to change the cam Shackle and G link combined into one part for fewer stress points and less chance of side loading damage Note: The pad should be replaced same time as cam 100% proof tested with certificate of test attached to each clamp Note: The Pad and Cam should be replaced at the same time Clamps are 100% Proof Tested and Certificate of Test supplied with each clamp
Cat. No. 6423000 6423920 6423921 6423005 6423923 6423924 6423010 6423925 6423926 6423015 6423020 Dimensions E mm in. mm 67 2 67 2 67 2 78 2 78 78 51 51 51
1 1
UPC No. 020418 172199 175657 176005 172205 175664 176012 172229 175671 176029 177583 177590
1
16 - 8 5 8 - 1 18 1 5 1 8 - 1 8 1 16 - 34 3 4 - 1 38 3 1 8 - 2 1 16 - 1 3 1 - 1 4 3 1 1 4 - 2 2 1 2 - 2 1 2 - 2 12
G
1 - 16 16 - 28 28 - 41 1 - 19 19 - 35 35 - 51 1 - 25 25 - 44 44 - 64 13 - 51 3 - 64
2 2 1 2
1 1
1 1 1 3 3 3 5 10
Cat. No. 6423000 6423920 6423921 6423005 6423923 6423924 6423010 6423925 6423926 6423015 6423020
UPC No. A 020418 in. mm 172199 4 175657 5 176005 5 172205 175664 176012 102 127
1 3
B in. mm in.
C mm in. 241 2 241 241 286 286 286 356 356 356 508 762
D 56 2 56 56 78 78 78 90 90 90
F in. mm 105 105 105 133 133 133 171 171 171 219 349 in.
I mm 124 124 124 149 149 149 194 194 194 252 416
2 4 4 7 5 8 1 6 2
1
2 9 2 1 9 2
9
1 1
4 11 4 1 11 4
11
1 1
14 14 14 20 30
184 203
8 14 4
7 3
225 375
16 2 16 3 2 16 1 3 16 1 3 16 1 3 16 9 3 16 9 3 16 9 3 16 11 4 16 7 7 8
3 3
4 2 8 5 2 8 1 3 16 1 3 16 1 3 16 13 3 16 13 3 16 13 3 16
3 5 3
16 2 16 1 2 16
52 52 52 76 76 76
97 3 97 3 97 3 127 3
15
119 5 194 7
16 100
127
187 5
8 4 8 1 4 8 1 5 4 1 5 4 1 5 4 3 6 4 3 6 4 3 6 4 3 8 4 3 13 4
4
1 1
8 2 8 7 2 8 5 3 8 5 3 8 5 3 8 7 4 16 7 4 16 7 4 16 15 5 16 1 10 4
2
7 7
8 1 8 5 1 8 5 1 8 5 1 8 5 1 8
1
3 5
4 2 4 13 3 16 15 4 16
1 1
8 4 8 7 4 8 7 5 8 7 5 8 7 5 8 5 7 8 5 7 8 5 7 8 15 9 16 3 16 8
4
7 7
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
LIFTING CLAMPS
Clamp Weight lb kg 4 7 15 18 2 3 7 8
16 - 8 1 16 - 34 1 16 - 78 1 16 - 1
1 - 16 1 - 19 1 - 22 1 - 25
1 2 3
Cat. No.
C mm 54 67 67 87 in.
Dimensions E mm in. mm 67 78 84 97 2 2 2 3
1 1
F in. 4 4 5 6
9 1 7
H mm 35 42 41 51 in.
102
4 8
2 5 11 16 1 12 8 1 15 16
9
1
8 2 8 5 2 8 7 3 16
2
1 5
8 3 16 5 3 16 13 3 16
2
5 1
51
16 4
52 57 76
16 8 16
167
8 3 16 9 3 16 3 4 16
2
7 9
8 1 32 5 1 8
1
3 21
4 5 16 15 5 16 5 7 16
4
3 13
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
LIFTING CLAMPS
Capacity Part Name Shackle Radius Link T-Spring Conn. Link Cam Pad Cam Kit
2 TON
UPC No. 020418 Qty. Cat. No.
Cat. No.
Cat. No.
Cat. No.
Cat. No.
6501005 170720 1 6501105 170805 6501002 170706 1 6501102 170775 6501016 170751 1 6501116 170836 6501007 170737 2 6501107 170812 6501001 170690 1 6501201 170850 6501017 170768 1 6501117 170843 6505020 179020 1 6505021 179037
1 6501205 186226 1 6501305 170904 1 6501202 186196 1 6501302 170874 1 6501216 186264 1 6501316 170935 2 6501207 186233 2 6501307 170911 1 6501210 186257 1 6501301 170867 1 6501217 186271 1 6501317 170942 1 6505029 186288 1 6505022 179044 2 6501203 186202 2 6501303 170881 1 6501204 186219 1 6501304 170898
1 6501505 178986 1 6501502 178955 1 6501516 179006 2 6501507 178993 1 6501501 179099 1 6501517 179013 2 6505023 179051 2 6501503 178962 1 6501504 178979
2 6501707 184956 1 6501701 184918 1 6500511 172236 1 6505024 184970 2 6501703 184932 1 ** -
*Cam & Radius Link Pin 6501003 170713 3 6501103 170782 *Pad Pin *** Rivets 6501008 170744 3 6501108 170829 ** - 6501104 170799
3 6501508 179105
3 6501708 184963
* Drive pins included. ** The swivel pad pin on this model is the same as the cam and radius link pin. *** Pad Pin for 3 Ton GX Clamp (6423926) is 6501315 Includes cam, pad and rivet.
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
LIFTING CLAMPS
Chain Connector
Chain connector attaches to GX and GXL clamps Chain connector increases the flexibility of multiple leg chains Made of drop forged and heat treated alloy steel Kit includes connector, pin and rivet Note: Connector not recommended for use with wire rope
2-Ton "GX"
1 3 5
32 8 1 2 5 8
3
7 9 13 16
mm
Weight lb kg
1 3 5
1
16 - 516 1 16 - 34 1 16 - 1 1 2 - 2 16 - 58 1 16 - 34 1 16 - 1
1 - 16 1 - 19 1 - 25 13 - 51
5 9 18 40
2 4 8 18
Two-Part Sling
Short Leg Structural "GX" Style 6423800 6423805 6423810 177361 177378 177385
1 - 16 1 - 19 1 - 25
5 10 19
2 5 9
1 3
Two-Part Chain Slings And Mini-Slings are available as illustrated, but on special order only. Slings employ alloy master link, Quik-Alloy coupling link(s), Campbell Cam-Alloy chain and "GX", or Short Leg Structural "GX" style clamp(s) listed above. Mini-Sling
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
LIFTING CLAMPS
Clamp Weight lb kg 6 22 55 3 10 25
16 - 38 1 16 - 58 1 16 - 78
1-9 1 - 16 1 - 25
1 3
Capacity Grip Part Name Shackle Radius Link Conn. Link Smooth Cam Pin for Cam & Radius Link Rubber Pad Spring Linkage Rivet for Shackle Linkage Rivets for Cam&Radius Link
* Drive Pins Included.
1 TON
1
3 TON
1
16" - 34"
UPC No. 020418 170805 184840 184833 184864 184857 170881 170928 170829 170935
16" - 34"
UPC No. 020418 170904 184888 184871 184901 178962 184895 179006 170928 179105
Pkg Qty. 1 1 2 1 2 1 1 1 2
Cat. No. 6501005 6501013 6501009 6501099 6501103 6501096 6501116 6501008 6501108
UPC No. 020418 170720 184802 184796 184826 184819 170782 170829 170836 170744
Cat. No. 6501105 6501113 6501109 6501199 6501303 6501196 6501316 6501108 6501308
Cat. No. 6501305 6501313 6501309 6501399 6501503 6501396 6501516 6501308 6501508
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
LIFTING CLAMPS
Locking E Clamps
Clamp lifts from either horizontal or vertical position Clamps turn plates through 90 Locks open or closed with a lever Has large throat that gives a secure bite and wide grip range Note: Be sure clamp is in lock closed position before making lift Clamps are 100% Proof Tested and Certificate of Test supplied with each clamp
Grip Range in. mm
1 1
Cat. No. 6420701 6420702 6420703 6420705 6420706 6420707 6420708 6420709 6420710 6420711 6420712 6420713
Clamp Weight lb kg 20 28 33 81 84 9 13 15 37 38 49 35 38 53 66 72 77
4 0 - 1 2 1 1 1 4 - 2 2 1 2 - 2 12
0-1 2-4 4-6
1
0 - 32 0 - 38 32 - 64 13 - 64 51 - 102
2 - 2 2
1
2-4 4-6
096204 096211
096228 096235
20E
2 - 3 1 3 - 5 2 1 5 2 - 8
1
Made to order
Cat. No. 6420701 6420702 6420703 6420705 6420706 6420707 6420708 6420709 6420710 6420711 6420712
B in. 14 16 16 22 23 25 22 23 26
3 3 5 3 3
Dimensions D in. mm
E in. 2 mm 51
1 1
H in. 2 2 3
11 1 7
J mm 51 in. 4 5
3
mm 111 127
4 8 8 1 10 2 1 14 8
7
1 7
8 8 4 4 4
16 18
4 1 10 2 1 11 4 3 15 4 1 16 4 7 18 8
9
1
2 3 2 1 3 2
3
1 1
5 5 5 5 5 5 5 5 5
096204 096211
096228 096235
6420713
4 16 4 1 18 2 1 16 2 1 19 2 1 21 2
14
16 16 19
413 483
4 26 8 1 26 4
25
1 3
4 18 4 1 18 4
17
1 1
2 2 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2
2
64 64 89 89 89 89 89 89 89 89 89
16
8 4 8 1 5 16 1 5 4 7 4 8 1 5 2 7 5 16 1 6 8 1 6 2 1 6 2
4 8 2 3 8 4 1 10 4 1 8 2 3 8 4 1 10 4 1 8 2 3 9 4 3 9 4
5
1 1
133 216 222 260 216 222 260 216 248 248
Made to order
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
LIFTING CLAMPS
Capacity Grip Part Name Cam (with pin for spring) Cam Pin Shackle Shackle Pin Swivel Pad Spring w/eyes & pin Chain Pull Tension Arm w/swivel pin* Swivel Pin (included w/tension arm) Pin for Spring (included w/spring) Tension Arm Spring Assembly Kit includes Parts 516,227 & 508 Tension Arm Spring Assembly Kit includes Parts 526, 227 & 507
Merrill Part No. 311 514 515 514 310 516 227 508 +509 520 300 -
3 Ton 0 - 1 14" Cat. No. 6500311 6500514 6500515 6500514 6500310 6500516 6500227 6500508 +6500509 6500520 6500300 -
5 Ton UPC No. 020418 098536 099014 099021 099014 098529 099038 098321 098970 098987 099045 098437 Merrill Part No. 541 522 523 522 510 526 227 507 509 520 500 0 - 1 12" Cat. No. 6500541 6500522 6500523 6500522 6500510 6500526 6500227 6500507 +6500509 6500520 6500500 UPC No. 020418 099199 099052 099069 099052 098994 099083 098321 098963 098987 099045 098956 1 14 - 2 12" Merrill Cat. Part No. No. 541 512 523 512 510 526 227 507 +509 520 500 6500541 6500512 6500523 6500512 6500510 6500526 6500227 6500507 +6500509 6500520 6500500 098956 UPC No. 020418 099199 099007 099069 099007 098994 099083 098321 098963 098987 099045
* Drive Pins Included. Two Pins are required for part numbers 507 and 508. + Packed two per standard pack; all other parts are packaged one per pack.
Capacity Grip Part Name Cam (with pin for spring) Cam Pin Shackle Shackle Pin Spring w/eyes & pin Chain Pull Tension Arm w/swivel pin
2 - 2 12"
Cat. No.
Merrill Part No. 531 542 533 534 536 537 538
12 Ton 2 - 4" and 4 - 6" All Grips UPC No. Merrill Cat. UPC No. Merrill Cat. 020418 Part No. No. 020418 Part No. No. 099090 099205 099113 099120 099144 099151 099168 099175 184765 172236 531 542 543 544 536 537 538 539 540 511 6500531 6500542 6500543 6500544 6500536 6500537 6500538 6500539 6500540 6500511 099090 099205 099212 099229 099144 099151 099168 099175 184765 172236 531 542 543 544 536 537 538 539 540 511 6500531 6500542 6500543 6500544 6500536 6500537 6500538 6500539 6500540 6500511 -
8 Ton
20 Ton All Grips UPC No. Merrill Cat. 020418 Part No. No. 099090 099205 099212 099229 099144 099151 099168 099175 184765 172236 551 552 553 554 536 537 538 539 540 511 555 6500551 6500552 6500553 6500554 6500536 6500537 6500538 6500539 6500540 6500511 6500555
UPC No. 020418 184772 184789 173820 099250 099144 099151 099168 099175 184765 172236 173837
6500531 6500542 6500533 6500534 6500536 6500537 6500538 6500539 6500540 6500511 -
Swivel Pin (included w/tension arm) 539 Pin for Spring (included w/spring) Swivel Pad Pin for Swivel Pad 540 511 -
Note: Double Tension Arm is now standard on 3 and 5 Ton Models and is supplied with swivel pins, drive lock & spacer. If you have a 3 or 5 Ton Clamp equipped with Single style arm, ask for simple instructions to convert to improved Double style.
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
LIFTING CLAMPS
Cam under load. The heavier the load, the greater the bite.
Recommended for turning plates from horizontal to vertical as well as through a 180 arc The convex, serrated cam swivels on a ball joint so that the area of cam engagement increases as load increases Drop forged body and shackle Clamps are 100% Proof Tested and Certificate of Test supplied with each clamp Note: SCREW NEEDS TO BE HAND TIGHT ONLY! DO NOT OVERTIGHTEN.
Grip Range in. mm 0 - 1 0 - 25 0 - 2 0 - 51 0 - 3 0 - 76 Clamp Weight lb kg Working Load Limit Metric Ton 1 3 6
Cat No.
4 1 14 4
6
1
3 6 18
40
C mm 102 in. 1
3
D mm 44 48 83 in.
E mm 73 86 114 in.
F mm 13 19 29 in.
H mm 38 60 76 in.
J mm 57 86 76 in. 6
1
P in. mm
23 13 1
4 3 7 4
5
1
10
4 1 10 2 1 14 4
7
3
2 4
165 210
4 7 1 8 1 3 4
8 3 3 8 1 4 2
2
7
2 3 4 1 1 8
1
2 3 2 8
1
1
4 3 3 4 1 4 2
2
1
4 1 9 4
12
64 16
34.5 46 57
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
LIFTING CLAMPS
Cat. No.
Clamp Weight lb kg 10 32 5 15
6421010 096426
0 - 25 0 - 32
6421012 096433 0 - 1
Dimensions Cat. No. 6421010 6421012 UPC No. 020418 096426 096433 A in. mm 124 171 Max. B in. mm 16 21 4
3
C in. 7
1
E mm 152 in. 3 8
H mm 86 111 in.
J mm 105 121
Max. W in. mm 6 2 10
1
3 6 4
4 8
7
406
552
9 4 235
3 2 8
7
7 4 184
3 4 8
3
3 4 4
4 8
1
165 254
Attaches to beams for overhead lifting. Lifts and turns structural shapes.
Lifts plates.
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
LIFTING CLAMPS
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
LIFTING CLAMPS
4 Ton Cat. No. 6421610 Merrill Cat. UPC No Part No. No. 020418
3
Clamp Weight lb kg 5 11 23 2 5 10
16 - 58 1 16 - 34 1 16 - 1
1 3
Clamp Weight lb kg 5 9 26 2 4 12
16 - 8 1 16 - 34 1 16 - 1
5
1 3
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
LIFTING CLAMPS
One man can handle plates with this clamp Dual springs hold cam on the work while the second clamp is placed Sold in pairs ONLY Clamps are 100% Proof Tested and Certificate of Test supplied with each clamp
Working Load Limit UPC No. Per Pair 020418 Metric Ton 6 Grip Range in. 0-1
1
Width in.
3
A in. 4
1
B mm 114 in. 1 mm 25
D mm 25 in. 7
1
O mm
Cat. No.
mm
mm 19
6421701 096686
0-38
191 30 13.6
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
LIFTING CLAMPS
Designed to carry or pull any object that will fit into its jaws Grips and releases automatically
Working Load Limit lb kg 500 500 500 500 500 227 227 227 227 227
Dimensions J in. mm
O in. mm 95 95 95 95 95
Weight lb kg 2 2 3 3 4 1 1 1 1 2
16 5 0 - 16 5 0 - 16 5 0 - 16 5 0 - 16
05
8 7 1 8 7 1 8 7 1 8 7 1 8
1
7
48 48 48 48 48
4 3 4 3 3 4 3 3 4 3 3 4
3
3 3
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
LIFTING CLAMPS
mm
3
Weight lb kg 4
3
44
13 x 19
22
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
CHAIN SLING
&
DRUM LIFTER
Complete Sling Merrill Model No. 13 Working Load Limit at 60 Metric Ton 1 Overall Length in. mm 27 686 Alloy Chain Size in. mm
9
Weight lb 13 kg 6
32
454
Unopened drum
Pouring
Top removed
Weight lb 22
3
kg
2 - 25 2 - 25
10 11
24
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
DRUM DEHEADER
Length of Tool Description Deheader with alloy blade Deheader with non-sparking blade in. 24 24 mm 610 610 lb 5 5
1 1
Weight kg 2 2
2 2
2 2 1 16 1 8
1 1
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.
DRUM LIFTER
Dimensions Merrill Model No. 260 Min. Space Between Forks in. mm 5
1
Cat. No.
Width in. mm 6
1
lb 445-635
Working Load Limit Using Using Center Clamps Shackles Metric Ton Metric Ton 1 3
Weight lb kg 29 13
6410501 095696
140
44
159
2-25
Gripper blades Pins for gripper blades Springs Rivets for blades Lifter Links Clamps with Lifter links
ADVERTENCIA
Seleccione el tamao de mordaza adecuado para el trabajo. Determine el peso de la placa a ser alzada. No exceda el limite de carga de trabajo (WLL) mostrado en la mordaza. El espesor de la placa debe estar dentro de la gama de agarre mostrada en la mordaza.
WARNING
Select proper size clamp for the job. Determine the weight of the plate to be lifted. Do not exceed WLL (Working Load Limit) shown on clamp. Plate thickness must be within grip range shown on clamp.