DC OK output The CP-E range 24 V devices > 18 W offer a semiconductor output for function monitoring and remote diagnosis.
Wide range input Optimized for world-wide applications: The CP-E power supplies can be supplied with 85-265 V AC or 90-375 V DC.
Output voltages 5 V, 12 V, 24 V, 48 V DC Adjustable output voltages Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / 3 A Power range 15 W, 18 W, 30 W, 60 W Wide range input 100-240 V AC (90-265 V AC / 120-370 V DC, 85-265 V AC / 90-375 V DC) High efficiency of up to 89 % Low power dissipation and low heating Free convection cooling (no forced cooling with ventilators) Ambient temperature range during operation -10...+70 C Open-circuit, overload and short-circuit stable Integrated input fuse U/I characteristic curve for devices > 18 W (fold-forward behavior at overload no switch-off) Redundancy unit CP-RUD offering true redundancy LED(s) for status indication Signalling output (transistor) for output voltage OK on 24 V devices > 18 W Approvals / Marks (depending on device, partly pending):
11
Adjustable output voltage The CP-E range types feature a continuously adjustable output voltage. Thus, they can be optimally adapted to the application, e.g. compensating the voltage drop caused by a long line length.
A, H, B, D, E / a, b
Redundancy unit CP-RUD 1SVR 423 418 R9000 For decoupling of parallellized power supply units. Thus, true redundancy can be achieved.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
r we ies o P pl p su
Type
Order code
Weight 1 piece kg / lb
CP-E 5/3.0 CP-E 12/2.5 CP-E 5/3.0 CP-E 24/0.75 CP-E 24/1.25 CP-E 24/2.5 CP-E 48/0.62 CP-E 48/1.25 CP-E 12/2.5
1SVR 427 033 R3000 1SVR 427 032 R1000 1SVR 427 030 R0000 1SVR 427 031 R0000 1SVR 427 032 R0000 1SVR 427 030 R2000 1SVR 427 031 R2000
1 1 1 1 1 1 1
0.15 / 0.33 0.29 / 0.64 0.15 / 0.33 0.29 / 0.64 0.36 / 0.79 0.29 / 0.64 0.36 / 0.79
11
Redundancy module The CP-RUD monitors two CP-E range power supplies with an output current of up to 5 A each. If one power supply fails, CP-RUD automatically switches to the alternate supply without interruption of the load current. Max. voltage 40 V.
Pack. unit pieces Weight 1 piece kg / lb
Type
Description
Order code
Redundancy module
0.15 / 0.33
CP-E 48/0.62
CP-RUD
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
P su owe pp r lie s
CP-E 24/1.25
47-63 Hz
2 A slow-acting / 250 V AC
Output circuit Rated output voltage Tolerance of the output voltage Adjustment range of the output voltage Rated output power Rated output current Ir Derating of the output current Signalling output for output voltage OK Deviation with load change Ta m 60 C 60 C < Ta m 70 C DC OK statical dynamic 10-90 % change of input voltage within the input voltage range Control time Starting time after applying the supply voltage Response time Residual ripple and switching peaks Parallel connection Series connection Resistance to reverse feed Power factor correction (PFC) Output circuit - No-load, overload and short-circuit behavior Output curve Short-circuit protection Short-circuit behavior Overload protection at Ir at rated load BW = 20 MHz
11
3.0 A 3 %/K
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
r we ies o P pl p su
Weight Material of enclosure Mounting Mounting position Minimum distance to other units Degree of protection Protection class Electrical connection - Input circuit / Output circuit Wire size
11
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
P su owe pp r lie s
CP-E 48/1.25
V: output voltage OK
L+,L48 V DC 1 % 48-55 V DC 60 W 1.25 A 48 V DC
11
max. 1 %
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
r we ies o P pl p su
11
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
P su owe pp r lie s
11
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
r we ies o P pl p su
Technical diagrams
Output curve at Ta = 25 C
Uout [V] 15 13 11 9 7 5 3 1 Uout [V] Uout [V]
CP-E 12/2.5
2.8
2.9
3.0
3.1
3.2
3.3
3.4
3.5
CP-E 24/1.25
1.25 1.35 1.45 1.55 1.65 1.75 1.85 1.95 2.05 2.15 Iout [A]
CP-E 24/2.5
2.75 2.85 2.95 3.05 3.15 3.25 3.35 3.45 3.55 3.65 Iout [A]
Uout [V] 70 60 50
Uout [V] 70 60 50 40 30 20 10
11
40 30 20 10
0.665 0.705 0.745 0.785 0.825 0.865 0.905 0.945 0.985 1.025
CP-E 48/0.62
Iout [A]
CP-E 48/1.25
1.33 1.41 1.49 1.57 1.65 1.73 1.81 1.89 1.97 2.05 Iout [A]
CP-E
Wiring instructions
RL > 700 q DC OK DC OK
Relay
5 V Signal
2.2 kq 0.5 W 5.1 V 0.3 W
L-
L-
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
P su owe pp r lie s
23,9 [0.94]
43,5 [1.71]
115 [4.53]
88,5 [3.49]
CP-RUD
109,5 102 [4.31] 22,5 [.886]
[4.02]
88,5 [3.48]
11
78 [3.07] 100 [3.94]