You are on page 1of 2

PROJECT : Project name

FLOOR : 6th Y Hx
ZONE : -
COLUMN : 3/J
D A
LOCATION TYPE (I, E, C) E
Cx
Dimension :
t (Slab thickness) 350 mm
Cy Hy
Cx (Column width in X dir.) 843 mm X
Cy (Column width in Y dir.) 422 mm
Hx (Opening width in X dir) 0 mm C B
Hy (Opening width in Y dir) 0 mm
bB (RC beam width) 0 mm CCD CAB
DB (RC beam depth) 0 mm
Material properties :
f'c (Cylinder concrete strength) 32 MPa
fy (Yield strength of shear steel) 400 MPa
Loads :
Vu (Factor Shear) 764 kN
Mux (Factor Moment for X-axis) 698 kN.m
Muy (Factor Moment for Y-axis) 160 kN.m
Shear capacity :
φ 0.85
bo 2323 mm
d 318 mm
AC 738714 mm2
Vp 0 kN
fpc 0 MPa
αs 30
βc 1.998
βp 0.29
φVc 1183.99 kN
φvc 1.60 MPa
Max. Shear stress :
bX 1161 mm
bY 581 mm
CAB 581 mm
CCD 581 mm
CBC 436 mm
CAD 145 mm
γVX 0.485
γVY 0.320
JX/C 291303423 mm4
JY/C 200213221.26 mm4
v (due to Mux) 1.163 MPa
v (due to Muy) 0.256 MPa
Max. vu 2.225 MPa
Check : Shear reinforcement is required
Shear reinforcement required :
Require Vs 1236.92 kN
Av/S (240MPa) 16.207 mm2/mm
Av/S (400MPa) 9.724 mm2/mm
Shear reinforcement provided :
Min. spacing (limit) 159 mm
Min. Av (limit) 212.94 mm2
Bar Daimeter. 12 mm
No. of legs of shear stirrup 12 Nos.
S (Spacing) 110 mm
Av 1357.17 mm2
Shear capacity (with shear reinforcement) :
Vs 1569.38 kN
CHECK O.K.
Distance from column face to edge stirrup, LS :
Ls , Required 385 mm