DATA SHEET

AIR CONDITIONING SYSTEM


CONTROLLER

GL-E1103 THERMOSTAT

April 2012
Revision IE
Software version 1.1

SUMMARY
GL-E1103 THERMOSTAT..........................................................................................................1
Def..................................................................................................................................................3
4C..................................................................................................................................................3
0C..................................................................................................................................................3
0......................................................................................................................................................3
30C................................................................................................................................................3
16C................................................................................................................................................3
4C..................................................................................................................................................4
1C..................................................................................................................................................4
1C..................................................................................................................................................4
4C..................................................................................................................................................4
1......................................................................................................................................................4
2min................................................................................................................................................4
60s..................................................................................................................................................4

4) PARAMETERS PROGRAMMING

To access the system parameters, press, simultaneously, the


for 3 seconds.

To insert the password, press

and

buttons

to increment the most significant digit and

to

increment the less significant digit until the number 53 is shown on the display, then
press
to enter in the parameters or press
to exit;

The first parameter is P0. To access other parameters press


or
;

To visualize the parameter value, press


, and to change the value press
or
;

To return to the parameters indication, press


or
button to exit.
System Parameters
Parameter

P0
P1
P3
P4
P5
P7
P8
P9

Function

Def

Min

Max

Return temperature sensor off-set

4C

-5C

+5C

0C

-5C

+5C

30C

0C

35C

16C

-19C

24C

0s

0s

60s

0s

0s

6s

External temperature sensor off-set


Blower speed overlapping mode 3 speeds
(Its valid when tu = 00)
0 = overlapping
1 = without overlapping
2 = delay 1s
Maximum setpoint temperature
Minimum setpoint temperature
Delay for activating the output 6 after output 2 is ON
(Its not valid when tu = 0)
Enable decimal point to flash in blackout mode
(Not flashing = 0; Flashing = 1)
Delay for activating the output 3 after output 2 is ON
(Its not valid when tu = 0)
(Its not valid when defrost ON)
3

PA
dC
dt
dH

Automatic ventilation control parameter

4C

1C

6C

Temperature differential for refrigeration

1C

1C

4C

Temperature differential for heating

1C

1C

6C

4C

1C

4C

0.5

0.5

1.0

0s

0s

10s

5C

5C

10C

2min

20min

60s

0s

60s

0min

0min

6min

Difference from setpoint and heating setpoint


Default visualization
SL
(Temperature = 0; Setpoint = 1)
Ventilation mode
0 = 3 speeds (mode relay)
tu
5 = PWM (6 speeds)
Ventilation differential to 6 speeds (PWM)
Pu
Delay for activating the output 3 after output 6 is ON
Pb
(Its not valid when tu = 0)
Minimum external temperature to allow the compressor to
Py
turn ON
Defrost ON period
td
Minimum time that clutch stays ON before goes OFF and
tC
vice versa
Hysteresis between to turn off and to turn on
PH
(Its not valid when defrost ON)
Obs.: If P4 = P5 the display will show the bL message upon setpoint
indicating that the setpoint value is blocked.
Obs.: If td = 0 Defrost for unlimited time.

temperature changing,

4.1) Adjustment and Speed Control When tu = 05

When parameter tu = 05, its possible adjust PWM speeds manually. To access
the system parameters, press, simultaneously, the
and
buttons for 3 seconds.

To insert the password, press

to increment the most significant digit and

to

increment the less significant digit until the number 27 is shown on the display, then
press
to enter in the parameters or press
to exit;

The first parameter is C0. To access other parameters press


or
;

To visualize the parameter value, press


, and to change the value press
or
;

To return to the parameters indication, press


or
button to exit.

Parameter

Function

Def

Min

Max

C0
H1
H2
H3
H4
H5
H6

Duty signal

00

00

01

PWM speed 1

27

00

99

PWM speed 2

37

00

99

PWM speed 3

50

00

99

PWM speed 4

66

00

99

PWM speed 5

81

00

99

PWM speed 6

90

00

99

5) OUTPUT VISUALIZATION MODE


This panel allows the visualization of the outputs states in order to make possible to
check whether the outputs are activated or deactivated, during operation.

To access the output visualization mode, press, simultaneously, the

buttons for 3 seconds, and insert the password

11, and press the

and

button.

Indicate the current


output state

To change the output visualization, press


or
buttons.
To exit this mode press the
button.
The displays decimal point will represent the current state of the outputs in this mode
of visualization:
If its lit, indicates that its activated.
If its not lit, indicates that its not activated.

When tu = 0

When tu 0

Indication

Description

Indication

Description

u1
u2
u3
CL
Ht

Low speed evaporator output

u1
u2
u3
u4
u5
u6
CL
C2
C3
Ht

PWM speed 1

Medium speed evaporator output


High speed evaporator output
Compressor output
Heating output

PWM speed 2
PWM speed 3
PWM speed 4
PWM speed 5
PWM speed 6
Compressor 1
Compressor 2
Compressor 3
Heating output

6) TEST MODE
Use this mode to test the outputs, where its possible to change their states.
To access the test mode, press simultaneously the
and
for 3 seconds.

To insert the password, press

to increment the most significant digit and

to

increment the less significant digit until the number 86 is shown on the display, then
press
to enter in the parameters or press
to exit;
The first test is u1 , to access the other tests, press the
or the
button;
To enable an output, press
and to disable it press
again;
To exit this mode press the
button.

Indication

Description

u1

Low speed evaporator output


6

u2
u3
u4
u5
u6
Ht
CG

Medium speed evaporator output


High speed evaporator output
PWM 33%
PWM 66%
PWM 100%
Heating
Gas charge (compressor and low speed evaporator)

7) FAILURES
Failure

Description

Action

F1
F2

Internal Temperature Sensor

The controller assumes 22C

External Temperature Sensor

The controller assumes 22C

8) PROTECTIONS

The control panel exits are protected against short circuit with a thermal circuit.
The maximum output current per pin is 180mA.

9) OPERABILITY
This controller must operate in a range of temperature from -9C to 60C.
This controller operates with nominal tensions of 12 and 24V DC.
Under continuous mode, it must operate with tension from 10 to 29V DC, with the
integrity of all functions.
The electronic system must support 32V DC for five minutes, suffering no permanent
damage.
The control circuit must support -12V DC / -24VDC (polarity inversion) indefinitely,
suffering no damage.