You are on page 1of 1

Power and control cables

LFLEX

Various applications
PVC outer sheath and coloured cores

LFLEX CLASSIC 100

UNITRONIC

Info
Up to 5 cores and 1.5 mm: new items

with reduced core insulation thickness

Customised colour option and printing

ETHERLINE

on the outer sheath are available upon


request

Benefits
Space-saving installation due to small cable

HITRONIC

diameters
High electrical performance due to 4 kV test
voltage
HIgh flexibility due to short-twisted conductor
layers

Product features
Flame-retardant according to IEC 60332-1-2
Good chemical resistance

Technical data

see Appendix T1
Approvals

EPIC

Industrial machinery
Heating and air-conditioning systems
Power stations
Dry or damp rooms that are subject to medium mechanical loads
For fixed installation as well as occasional
flexing at free, non-continuously recurring
movement without tensile load

Up to 5 cores: colour-coded according to VDE


0293-308, refer to Appendix T9
From 6 cores: LFLEX colour code, refer to
Appendix T7
Based on

Application range
Plant engineering

Core identification code

IEC 60227-5
HD 21.5 S3; VDE 0281 Part 5
HD 21.13 S1; VDE 0281 Part 13

Design
Fine-wire strand made of bare copper wires
PVC insulation LAPP P8/1
Cores twisted in layers
PVC outer sheath, grey (RAL 7001)

Specific insulation resistance

> 20 GOhm x cm
Conductor stranding

Fine wire according to VDE 0295,


class 5/IEC 60228 class 5
Minimum bending radius

Occasional flexing: 15 x outer diameter


Fixed installation: 4 x outer diameter
Nominal voltage

SKINTOP

Up to 1.5 mm: U0/U: 300/500 V


From 2.5 mm: U0/U: 450/750 V
From 2.5 mm, in the case of fixed and protected installations: U0/U: 600/1000 V
Test voltage

4000 V
Protective conductor

G = with GN-YE protective conductor


X = without protective conductor

SILVYN

Temperature range

Occasional flexing: -5C to +70C


Fixed installation: -40C to +80C

FLEXIMARK

Article
number

Number of cores and


mm per conductor

Outer diameter
(mm)

APPENDIX

ACCESSORIES

LFLEX CLASSIC 100; U0/U: 300/500 V


00100004
2 X 0.5
00100014
3 G 0.5
00101224
3 X 0.5
00100024
4 G 0.5
00101234
4 X 0.5
00100034
5 G 0.5
00101244
5 X 0.5
0010004
6 G 0.5
0010005
7 G 0.5
0010006
8 G 0.5
0010007
10 G 0.5
0010008
12 G 0.5
0010009
14 G 0.5
0010010
16 G 0.5
0010011
21 G 0.5
0010012
24 G 0.5
0010016
40 G 0.5
00100214
2 X 0.75
00100224
3 G 0.75
00101254
3 X 0.75
00100234
4 G 0.75
00101264
4 X 0.75
00100244
5 G 0.75
00101274
5 X 0.75
0010025
6 G 0.75
0010026
7 G 0.75
0010027
8 G 0.75

22

1_HK_2012_Finalcompose_Oelflex_en.indd 22

4.8
5.1
5.1
5.7
5.7
6.2
6.2
6.7
6.7
8.0
8.6
8.9
9.5
10.0
11.7
12.4
15.4
5.4
5.7
5.7
6.2
6.2
6.7
6.7
7.3
7.3
8.8

Copper index
(kg/km)

Weight (kg/km)

9.6
14.4
14.4
19.2
19.2
24.0
24.0
28.8
33.6
38.4
48.0
58.0
67.0
76.0
99.0
114.0
192.0
14.4
21.6
21.6
28.8
28.8
36.0
36.0
43.3
50.4
56.0

35
42
42
54
54
63
63
73
81
97
116
133
151
169
223
254
404
45
55
55
66
66
79
79
104
109
123

Article
number

Number of cores and


mm per conductor

Outer diameter
(mm)

Copper index
(kg/km)

Weight (kg/km)

0010028
0010029
0010030
0010031
0010032
0010033
0010034
0010036
0010037
00100414
00100424
00102034
00100434
00102044
00100444
00102054
0010045
0010046
0010047
0010049
0010050
0010052
0010053
0010054
0010056
00100634
00100644
00101284

9 G 0.75
10 G 0.75
12 G 0.75
15 G 0.75
18 G 0.75
21 G 0.75
25 G 0.75
40 G 0.75
50 G 0.75
2 X 1.0
3 G 1.0
3 X 1.0
4 G 1.0
4 X 1.0
5 G 1.0
5 X 1.0
6 G 1.0
7 G 1.0
8 G 1.0
10 G 1.0
12 G 1.0
16 G 1.0
18 G 1.0
20 G 1.0
25 G 1.0
2 X 1.5
3 G 1.5
3 X 1.5

9.4
9.6
9.9
10.9
11.7
13.0
13.8
17.3
19.2
5.7
6.0
6.0
6.5
6.5
7.1
7.1
8.0
8.0
9.5
10.2
10.5
11.8
12.7
13.4
14.7
6.3
6.7
6.7

63.0
72.0
86.4
108.0
129.6
151.0
180.0
288.0
360.0
19.2
28.8
28.8
38.4
38.4
48.0
48.0
58.0
67.0
77.0
96.0
115.0
154.0
173.0
192.0
240.0
28.8
43.2
43.2

144
153
176
211
268
293
374
571
698
53
65
65
79
79
94
94
124
131
146
183
215
282
315
350
449
68
84
84

For current information see: www.lappgroup.com