Water
A water meter is a device used to measure the volume of water usage. water meters are used to measure the volume of water used by residential and commercial building that are supplied with water by a public water supply system.

OUR PRINCIPALS OVAL JAPAN ITRON Sure flow-japan Greentech Japan Ashlin Enterprises. Zenner Aqua met. B-Meter KENT POINTER ROTRONIC GWF E&H

Gases
A gas meter is used to measure the volume of fuel gases such as natural gas and propane. Gas meters are used at residential, commercial, and industrial buildings that consume fuel gas supplied by a gas utility.

Oil
Oil meters used for this purpose can measure and records the flow precisely. Oil metering is essential for widespread areas like industrial usage, automotive usage and marine. Our products provides you with the advanced quality control
www.zestengg.co.in

A device through which a liquid is passed for purification, filtering or separation from solid matter; anything any device functioning as a sieve or filter - in special, a perforated screen or openwork (usually at the end of a suction pipe of a pump), used to prevent solid bodies from mixing in a liquid stream or flow line.
Email-Sales@zestengg.com

Strainer

DOMESTIC WATER METER

Pulse Output Water Meter

Woltmann Type Water meters

(HOT &COLD) SINGLE JET/MULTI JET class A & Class B . size(15mm to 50mm) FEATURES Cold water 0-30C Hot water 30-90C Max working pressure 5 bar Mechanical transmission. Direct reading by numerical rolls. Low Head Loss

(HOT &COLD) SINGLE JET/MULTI JET class A & Class B . size(15mm to 500mm) FEATURES Cold water 0-30C Hot water 30-90C Max working pressure 16 bar Mechanical transmission. Direct reading by numerical rolls. Low Head Loss

(HOT &COLD) Woltmann Water meter class A & Class B . size(50mm to 500mm) FEATURES Cold water 0-30C Hot water 30-90C Max working pressure 16bar Mechanical transmission. Direct reading by numerical rolls. Low Head Loss

Electromagnetic flow meter


Electromagnetic flow meter, composed of sensor and converter, works based on Faraday's law of electromagnetic induction. It is used to measure electrical conductivity of liquid or solid. Generally, the electrical conductivity should be over 5uS/cm (electrical conductivity of tap water, raw water is about 100-500uS/cm.It can also be used to measure various mediums like acid, alkali, saline solution, paper pulp, ore pulp and so on, but these mediums can't contain a lot of magnetic materials and

Size-Dn15 - Dn1000
Electrode Material - 316L,Hc, Hb, Ti, Ta Application Liner Material - Neoprene, PTFE, PFA, F46 Effluent Treatment Plants Conductivity - Greater or Equal 5 s/cm Water Supply Schemes Accuracy - +/-0.5% of the value displayed Food & Drug Industry Protection Class - IP65, IP67 Dairy Industries Measuring Range-0.2 ~ 28000 m3/h Corrosive Liquids Pow. Supply - 3.6 V lithium battery. Type- Flange type /Inserted type / Battery Sugar Industry operated/ Integral type/ Triclover Type.
www.zestengg.co.in ZEST

Email-Sales@zestengg.com

LIQUID TURBINE FLOW METER


Specification
Size: 4~20 Temperature:-20C~120C Output:4~20mA DC and Pulse(Standard) Accuracy:+/-1.0% Connection: Screwed or Flange Power Supply Operating Temperature Ambient Temperature Accuracy Output Signal Display Service Flange Enclosure AC 85~230V, 50/60Hz or DC 24V or Battery (3 year) -20 ~ 120 Deg C -20 ~ 50 Deg C 1.0 %, 0.5% 4~20mA DC and Pulse (Standard) LCD 2 Line x12 character (Rate Flow /Total Flow) Clear Liquid, Gases ,Air, solvent. Screwed and Flange (As per standard) IP67,IP65

Turbine Flow meter

www.zestengg.co.in

Email-Sales@zestengg.com

Gas Turbine Flow Meters


Specifications
Material: Stainless Steel/Aluminum DN range (mm): DN15-DN200 Output: Pulse/current4-20Am/RS-485 Accuracy: 0.5% / 1% Operating Pressure Max - 6 bar Flow range (m / h): 1.0-3600 Power supply: 220VAC / 24VDC Medium temperature (centigrade): -30-65 Ambient temperature (centigrade): -20-80 Atmospheric pressure: 86-106KPa Nominal Pressure: 1.6, 2.5, 4.0, 6.4MPa Turbine gas meters infer gas volume by determining the speed of the gas moving through the meter.

Internal measurement Coal Gas Liquefied Gas Light hydrocarbon Gas Petroleum, chemical Industries Sewer Gas Diaphragm Type flow METERS A
Features:
1) High sensitivity, 2) high accuracy 3) Good stability and reliability 3) Low maintenance 4) Digital Display. 5) Pulse Out put. 6) Avaible-G1.6/G4 G16

Application

GTFM

Technical specifications:
1) Nominal flow rate: 1.6, 2.5m /h 3 2) Maximum flow rate: 2.5, 4m /h 3 3) Minimum flow rate: 0.016, 0.025m /h
3

4) Operating pressure range: 0.5 ~ 3kPa 5) Accuracy: B grade 6) Basic error limit: QminQ<0.1 Qmax, 3% 0.1 Qmax
QQmax, +/-1.5%. 7) Total Press Loss:< 250Pa

7) Operating Temperature:-10-+40deg

Vortex Flow Meter


Features:
* Size: DN 25 to DN 3000 Application

Vortex Flow Meter

* Service: Liquid / Gas / Steam * Pressure: 25 bar * Output Signal: 4-20 mA * Communication Interface: RS485 . * Accuracy: + / - 0.5%, + / - 1% * Repeatability: 0.2% * Protection: IP 65 / IP 68.

Stable long B term accuracy and repeatability No routine maintenance required

Lower cost of installation than traditional orifice-type meters Reduced possibility of process fluid leakage No moving parts to wear No special protection needed against extreme weather condition

D D

Features:
* Size: Inline: DN 4 to DN 300 * Insertion:DN 40 to DN 2000 (Max DN 3000) * Measuring range: 0.5 ~ 60 m/s * Service: Gas (except for acetylene) * Pressure:25 bar (High Pressure : 200 bar) * Accuracy: + / - 0.5%, + / - 1% * Repeatability:0.2%
Email-Sales@zestengg.com

Thermal mass Flow meter

:Compressed air flow and distribution :Carbon dioxide for chilling and fermentation :Argon in steel making :Nitrogen and oxygen production plants :Natural gas for burner and boiler feed control :Aeration air and bio gas in waste water

www.zestengg.co.in

D 4

OIL Meters
Flow Rate Temperature Pressure Viscosity Accuracy Nominal Bore Size Liquids Output 10 Lt/ Hr - 48M / Hr Upto 150 C 0-21 Kg/ cm (Optional 40 Kg/ cm ) 1000 CP maximum Within +(-) 0.5% (Optional +(-) 0.2% 15 mm, 20 mm, 25 mm, 40 mm, 50 mm, 80 mm Petroleum Products (MS, HSD, SKO, LDO, FO, LSHS). Totalisation of flow (Mechanical Counter) Optional Electronics
2 2 o 3

Oil flow meters are approved by Government of India, Department of Legal Metrology (Weights & Measures).

Application

Easy to connect with previous systems due to its high compatibility . Indication through 8-digit LCD display Wide range of flows and maintaining of high level of accuracy Easy to install due to its dimension conforming to previous products. Monitoring Oil Consumption Pressure, temperature and viscosity options

Oval Gear Flow meter

Specification
Oval gear positive displacement technology Accuracy +/-0.5% on pulse models, +/-1% on mechanical Suitable for lubricant, fuels and chemicals. Available for flow ranges from 2 to 1200 litres per minute Pipe sizes from 1/2" to 4" with BSP and flange connections Mechanical and electronic display options Pulse output and 4~20mA output models Multiple construction material options

Application
Petroleum Chemical Medicine Shipping

Food Syrup Greases Commercial department Solvent

Pressure, temperature and viscosity options LC Series oval gear oil flow meter, the main type of positive displacement flow meters is used to measure pressure in the pipeline closed under full pipe flow of the fluid flow. It has good adaptation and essentially unregulated measuring temperature, pressure change and easy of installation.

STRAINER

Type of Strainer
Simplex Basket Strainers Duplex Basket Strainers Y Type Strainers T Type Strainers Temporary Strainers Bag Filters

M.O.C. Housing Casted - C.I./C.S./S.S./G.M. Fabricated- M.S./S.S/P.P. Fiber/others on request Element- SS 304/SS, 316/Brass, Paper, Sintered. Size Range Casted - NB to 1 Screwed, BW, SW NB to 8 Flanged Fabricated- NB to 4 Screwed NB 1 to 60 Flanged

Application
Pumps Engines Flow meter Boilers Turbine RO Plants

www.zesteng.co.in

ZE

ST

Email-Sales@zestengg.com

RTD/Thermocouple

Pressure Gauges

Type of Pressure Gauges.


Normal Pressure Gauges Oxygen Pressure Gauges Vibration Free Pressure Gauges LPG Pressure Gauges CNG Pressure Gauges

Specification
RTDs may be purchased with 2, 3, or 4 lead wires Extending from the sensor. In determining the number of wires, consideration of the following is Important: Required accuracy Stability Receiving device location Corrosion potential - environmental conditions Nominal sensor range and resistance Dial Size : 2 ", 4", 6" , 8", 10" Case & Bezel : SS 304/ Die Cast Aluminum Weather Proof Pointer : Micro Zero or center zero adjustable Bourdon Material : SS 316/Brass Socket Material : SS 316/Brass Entry : Bottom Back Mounting : Direct, Panel, Surface Connection : ", 3/8", ", " and 1" BSP, NPT, Metric thread, Male/Female, adj./fixed Accuracy : + 1% of F.S.D. Over Range Protection : 125 % of F.S.D.

Specifications RTD type thermocouple, Industrial thermocouple, 1.J, S, K, PT100 type 2.water-proff/explosion-proof

A valve is a device that regulates, directs or controls the flow of a fluid (gases, liquids, fluidized solids, or slurries) by opening, closing, or partially obstructing various passageways.

Type of Valves
Gate Valve Ball Valve Sluice gate valve Check Valve Safety Valve Check Valve Butterfly Valve

Valves ZEST ENGINEERING


DE-58, SECTOR-3, INDUSTRIAL AREA- BAWANA NEW DELHI- 110039 INDIA Calls Us -+91-8800445945 Land line- 011-41561415 Email-new@zestengg.com Visit us-www.zestengg.co.in Sales office. ZEST ENGINEERING RAJAN NIWAS, NEAR M.C. OFFICE, RAJGARH ROAD. SOLAN (H P) Pin Code - 1732132 Phone- +919760158775 Email-sales@zestengg.com Visit us-www.zestengg.co.in

Type of Pipes
Sanitation System Pipes Plumbing System PVC Pipes Agriculture System PVC Pipe

Sales Office Zest Engineering 162,Sarla Bagh Dayal Bagh Agra 282005 Phone-9997098945