Professional Documents
Culture Documents
Water
A water meter is a device used to measure the volume of water usage. water meters are used to measure the volume of water used by residential and commercial building that are supplied with water by a public water supply system.
OUR PRINCIPALS OVAL JAPAN ITRON Sure flow-japan Greentech Japan Ashlin Enterprises. Zenner Aqua met. B-Meter KENT POINTER ROTRONIC GWF E&H
Gases
A gas meter is used to measure the volume of fuel gases such as natural gas and propane. Gas meters are used at residential, commercial, and industrial buildings that consume fuel gas supplied by a gas utility.
Oil
Oil meters used for this purpose can measure and records the flow precisely. Oil metering is essential for widespread areas like industrial usage, automotive usage and marine. Our products provides you with the advanced quality control
www.zestengg.co.in
A device through which a liquid is passed for purification, filtering or separation from solid matter; anything any device functioning as a sieve or filter - in special, a perforated screen or openwork (usually at the end of a suction pipe of a pump), used to prevent solid bodies from mixing in a liquid stream or flow line.
Email-Sales@zestengg.com
Strainer
(HOT &COLD) SINGLE JET/MULTI JET class A & Class B . size(15mm to 50mm) FEATURES Cold water 0-30C Hot water 30-90C Max working pressure 5 bar Mechanical transmission. Direct reading by numerical rolls. Low Head Loss
(HOT &COLD) SINGLE JET/MULTI JET class A & Class B . size(15mm to 500mm) FEATURES Cold water 0-30C Hot water 30-90C Max working pressure 16 bar Mechanical transmission. Direct reading by numerical rolls. Low Head Loss
(HOT &COLD) Woltmann Water meter class A & Class B . size(50mm to 500mm) FEATURES Cold water 0-30C Hot water 30-90C Max working pressure 16bar Mechanical transmission. Direct reading by numerical rolls. Low Head Loss
Size-Dn15 - Dn1000
Electrode
Material
-
316L,Hc,
Hb,
Ti,
Ta
Application
Liner
Material
-
Neoprene,
PTFE,
PFA,
F46
Effluent Treatment Plants Conductivity
-
Greater
or
Equal
5
s/cm
Water Supply Schemes
Accuracy
-
+/-0.5%
of
the
value
displayed
Food & Drug Industry Protection Class - IP65, IP67 Dairy Industries Measuring Range-0.2 ~ 28000 m3/h Corrosive Liquids Pow. Supply - 3.6 V lithium battery.
Type- Flange type /Inserted type / Battery
Sugar
Industry
operated/ Integral type/ Triclover Type.
www.zestengg.co.in ZEST
Email-Sales@zestengg.com
www.zestengg.co.in
Email-Sales@zestengg.com
Internal
measurement
Coal
Gas
Liquefied
Gas
Light
hydrocarbon
Gas
Petroleum,
chemical
Industries
Sewer
Gas
Diaphragm Type flow METERS A
Features:
1) High sensitivity,
2) high accuracy 3) Good stability and reliability 3) Low maintenance 4) Digital Display. 5) Pulse Out put. 6) Avaible-G1.6/G4 G16
Application
GTFM
Technical specifications:
1) Nominal flow rate: 1.6, 2.5m /h
3 2) Maximum flow rate: 2.5, 4m /h
3 3) Minimum flow rate: 0.016, 0.025m /h
3
4) Operating pressure
range: 0.5 ~ 3kPa
5) Accuracy: B grade 6) Basic error limit: QminQ<0.1 Qmax, 3% 0.1 Qmax
QQmax, +/-1.5%. 7) Total Press Loss:<
250Pa
7) Operating Temperature:-10-+40deg
* Service: Liquid / Gas / Steam * Pressure: 25 bar * Output Signal: 4-20 mA * Communication Interface: RS485 . * Accuracy: + / - 0.5%, + / - 1% * Repeatability: 0.2% * Protection: IP 65 / IP 68.
Lower cost of installation than traditional orifice-type meters Reduced possibility of process fluid leakage No moving parts to wear No special protection needed against extreme weather condition
D D
Features:
* Size: Inline: DN 4 to DN 300 * Insertion:DN 40 to DN 2000 (Max DN 3000) * Measuring range: 0.5 ~ 60 m/s * Service: Gas (except for acetylene) * Pressure:25 bar (High Pressure : 200 bar) * Accuracy: + / - 0.5%, + / - 1% * Repeatability:0.2%
Email-Sales@zestengg.com
:Compressed air flow and distribution :Carbon dioxide for chilling and fermentation :Argon in steel making :Nitrogen and oxygen production plants :Natural gas for burner and boiler feed control :Aeration air and bio gas in waste water
www.zestengg.co.in
D 4
OIL Meters
Flow Rate Temperature Pressure Viscosity Accuracy Nominal Bore Size Liquids Output 10 Lt/ Hr - 48M / Hr Upto 150 C 0-21 Kg/ cm (Optional 40 Kg/ cm ) 1000 CP maximum Within +(-) 0.5% (Optional +(-) 0.2% 15 mm, 20 mm, 25 mm, 40 mm, 50 mm, 80 mm Petroleum Products (MS, HSD, SKO, LDO, FO, LSHS). Totalisation of flow (Mechanical Counter) Optional Electronics
2 2 o 3
Oil flow meters are approved by Government of India, Department of Legal Metrology (Weights & Measures).
Application
Easy to connect with previous systems due to its high compatibility . Indication through 8-digit LCD display Wide range of flows and maintaining of high level of accuracy Easy to install due to its dimension conforming to previous products. Monitoring Oil Consumption Pressure, temperature and viscosity options
Specification
Oval gear positive displacement technology Accuracy +/-0.5% on pulse models, +/-1% on mechanical Suitable for lubricant, fuels and chemicals. Available for flow ranges from 2 to 1200 litres per minute Pipe sizes from 1/2" to 4" with BSP and flange connections Mechanical and electronic display options Pulse output and 4~20mA output models Multiple construction material options
Application
Petroleum Chemical Medicine Shipping
Pressure, temperature and viscosity options LC Series oval gear oil flow meter, the main type of positive displacement flow meters is used to measure pressure in the pipeline closed under full pipe flow of the fluid flow. It has good adaptation and essentially unregulated measuring temperature, pressure change and easy of installation.
STRAINER
Type of Strainer
Simplex Basket Strainers Duplex Basket Strainers Y Type Strainers T Type Strainers Temporary Strainers Bag Filters
M.O.C. Housing Casted - C.I./C.S./S.S./G.M. Fabricated- M.S./S.S/P.P. Fiber/others on request Element- SS 304/SS, 316/Brass, Paper, Sintered. Size Range Casted - NB to 1 Screwed, BW, SW NB to 8 Flanged Fabricated- NB to 4 Screwed NB 1 to 60 Flanged
Application
Pumps Engines Flow meter Boilers Turbine RO Plants
www.zesteng.co.in
ZE
ST
Email-Sales@zestengg.com
RTD/Thermocouple
Pressure Gauges
Specification
RTDs may be purchased with 2, 3, or 4 lead wires Extending from the sensor. In determining the number of wires, consideration of the following is Important: Required accuracy Stability Receiving device location Corrosion potential - environmental conditions Nominal sensor range and resistance Dial Size : 2 ", 4", 6" , 8", 10" Case & Bezel : SS 304/ Die Cast Aluminum Weather Proof Pointer : Micro Zero or center zero adjustable Bourdon Material : SS 316/Brass Socket Material : SS 316/Brass Entry : Bottom Back Mounting : Direct, Panel, Surface Connection : ", 3/8", ", " and 1" BSP, NPT, Metric thread, Male/Female, adj./fixed Accuracy : + 1% of F.S.D. Over Range Protection : 125 % of F.S.D.
Specifications RTD type thermocouple, Industrial thermocouple, 1.J, S, K, PT100 type 2.water-proff/explosion-proof
A valve is a device that regulates, directs or controls the flow of a fluid (gases, liquids, fluidized solids, or slurries) by opening, closing, or partially obstructing various passageways.
Type of Valves
Gate Valve Ball Valve Sluice gate valve Check Valve Safety Valve Check Valve Butterfly Valve
Type
of
Pipes
Sanitation System Pipes Plumbing System PVC Pipes Agriculture System PVC Pipe
Sales Office Zest Engineering 162,Sarla Bagh Dayal Bagh Agra 282005 Phone-9997098945
We have the right to modify the above written words without any notice.