XAR 603 BUILDING SERVICES QUESTION BANK

2 marks 1. List various types of air conditioning System. 2. What are the different types of centralized air conditioning system? 3. How the Buildings are graded according to fire resistance by National Building Code? Pg-558 4. List the types of Alarm systems. Pg-561 5. What are the characteristics of fire resistance material? Pg-558 6. List various types of fire protection system. Pg-566 7. What do you mean by thermal insulation of buildings? Pg-570 8. Differentiate between combustible and Non combustible material. Pg.556 9. List various types of fire protection systems. Pg-566

10. Write any two methods for fire resistance in Theatres and cinemas. Pg-565 11. What do you mean by AHU? 12. Define the term Fire load. Pg-555 13. How will you limit the spread of Fire? Pg-556 14. Give some examples for insulating materials. Pg-559 15. Define Thermal conductivity. Pg-572 16. Sketch the insulation of partition. Pg-577 17. Give reason : The timber used in heavy sections may attain a high degree of Fire resistance. Pg-559

18. Why the asbestos products are widely used for the construction of fire resistant partition walls, roofs, etc.?Pg-560 19. What are the types of water spray system?Pg-567 20. Name the principal components of Foam System.Pg-567

15 marks 1. Explain the fire resistance properties of common building materials in detail. Pg-558 2. Explain the meaning of Thermal Insulation. Mention its purpose and point out its advantages. Pg-570 3. Differentiate between the following (i) (ii) (iii) Automatic alarm system and manual alarm system. Pg-561 Superior Fire proof door and inferior fire proof door. Pg-562 Low fire load, moderate fire Load and high fire load. Pg-555

4. Explain the Split air conditioning systems. 5. Describe the various types of fire protection systems.Pg-566

6. Elucidate the features of packaged air conditioning systems. 7. What are the causes and effects of fire? Explain in detail.Pg-553 8. Explain the fire resistance behavior of steel and concrete.Pg-559,560 9. Write a detailed note on Automatic Sprinkler installation.Pg564 10. a)Give Sketches of the following (i)Door for strong Room Pg-568 (ii)Window for strong Room Pg-569 (iii)Treatment for Thermal insulation of Flat roof Pg 575 (iv)Treatment for Thermal insulation of Pitched Roof Pg575 11. State the general rules which are to be followed in the earthquake resistant construction of buildings.Pg569 12. . a) Give the reasons for the following (i)The sprinkler heads are provided with fusible plugs.Pg-564 (ii)The means of escape from fire should be easily accessible unobstructed and clearly defined (iii)It is desirable to provide Thermal Insulation to a building.Pg-571

(iv)For pre stressed structure, the cover to steel is of utmost importance from view point of fire Resisting construction

13. Explain the meaning of term fire load and mention the grading of occupancies by fire load as per BIS : 1641 1960 Pg-557 14. Describe the various types of fire protection systems. 15. Explain the meaning of Thermal Insulation. Mention its purpose and point out its advantages.

20 marks 1. Explicate the general rules for fire resisting buildings. Pg-561 2. Narrate about the centralized air conditioning systems

Air handler An air handler, or air handling unit (often abbreviated to AHU), is a device used to condition and circulate air as part of a heating, ventilating, and air-conditioning (HVAC) system. An air handler is usually a large metal box containing a blower, heating or cooling elements, filter racks or chambers, sound attenuators, and dampers. Air handlers usually connect to ductwork that distributes the conditioned air through the building and returns it to the AHU. Sometimes AHUs discharge (supply) and admit (return) air directly to and from the space served without ductwork. Small air handlers, for local use, are called terminal units, and may only include an air filter, coil, and blower; these simple terminal units are called blower coils or fan coil units. A larger air handler that conditions 100% outside air, and no recirculated air, is known as a makeup air unit (MAU). An air handler designed for outdoor use, typically on roofs, is known as a packaged unit (PU) or rooftop unit (RTU).

1 Air handler components o 1.1 Blower/fan o 1.2 Heating and/or cooling elements

o o o o

1.3 Filters 1.4 Humidifier 1.5 Mixing chamber 1.6 Controls

1.7 Vibration isolators