Perform steps 1 5 for a Measure Match (Sweep) test. Perform steps 6 10 for a Fault Location (DTF) test. Perform steps 11, 12, and 13 to measure RF power. Refer to the instruction manual for details. System information to have ready before you begin...
4 Frequency Span 4 Cable Type 4 Approximate Cable Length
Freq.
1
Scale
Press Escape in save mode to remove a recalled trace from the display without deleting it.
5 soThe unique
Delete
test. for e match r u s a e rse side rm e o v f e r y c n n o eque chart stem fr n from a p s y Enter sy c equen Enter fr t. DTF tes Start
8 5 2
9 6 3 +/-
Or
4
1
&
7 8 5 2
Enter
regis me label applicatio tration nu for m n m ore d s. Enter a ber is en ough n alp etaile h d ide ntific anumeric for ation .
Set the scale for optimal viewing. Set up the limit line if desired.
9 6 3 +/-
,
Enter
Or
4
1
&
Enter
Limit Line
Units
7 8 5 2 9 6 3 +/-
,
4
1
,
Cable Loss
Or
Enter
is the key to accurate 2 Calibration measurements and useful test results. Dont forget this step. And 7
Cali
at e br
&
Enter
And
Recall
Enter
10 8
Distance Scale
M Label N
Move column
Move cursor
Set the cable type and select units. Set the start and stop distance and set the scale for optimal viewing. Set up the smoothing and limit line if desired.
7 8 5 2 9 6 3 +/-
Utility
Delete
Enter
Save label
Start Stop
Attach each standard at the point the antenna will be tested, and press the corresponding key. There will be a beep to indicate the calibration is complete for that standard. After all standards press Cal Done.
Open
Short
Load
Or
&
Enter
Setup
, Save/Recall
Space
, Meters Feet
7
Enter
Cal Done
8 5 2
9 6 3 +/-
Or
4
1
&
Enter
Limit Line
Units
7 8 5 2 9 6 3 +/-
,
4
1
Enter
Escape
, Or
&
Enter
The escape key allows you to back up one menu level and to exit a setting without changing the value.
11
Display Fwd/Refl/Match
and units.
Enter
, Or
4
1
&
Enter
PwrUnit Watts/KWatts/dBm
Caution +22 dBm max input Do not apply RF power to the Antenna Test Port.
13
M1 On/Off/Active
System
(Time/Date) M2 On/Off/Active
Offset , Fullscale
7 4
1
8 5 2
9 6 3 +/-
Printer
DM
Off/Single
&
Enter
FM Mod
On/Off
30303 Aurora Road Cleveland (Solon), Ohio 44139-2794 Phone: (440)248-1200 Fax: (440)248-5426 http://www.bird-electronic.com
Electronic Corporation
Form No.: 920-SAT-REF Rev G Copyright 2002 Bird Electronic Corporation Printed in the U.S.A.
Rtn to Defaults
Screen Description
Mode Indicator Soft Key Description
Save/ Recall
Component Description
Mode Keys Mode: Activate mode menu Config: Activate configure menu for selected mode Calibrate: Activate calibration menu Marker: Activate marker menu Numeric Keypad Soft Keys Activate the function described directly to the right of the key
Marker Cursor
Battery Gauge
Limit Test On
VSWR
Auto Scale
DC Input
M2
Run
1.00
825.00
Calibration: Full Limit: 1.43 FAIL
MHz
M1: 835.20 MHz M2: 831.50 MHz DM: 3.70 MHz
841.00
1.64 1.20 0.44
Calibration Status
Limit Line
Marker Value
Scale
Status Indicator
Primary Measurement
Fwd
0.0 Watts
600.00
Primary Value Full Scale
Frequency Span (MHz) = Stop Frequency (MHz) - Start Frequency (MHz) Distance (ft) = Velocity of Propagation (Vp) x 117,000 / Frequency Span (MHz) Resolution (in) = Distance (ft) x 12 / (238 Data Points - 1) Distance (m) = Velocity of Propagation (Vp) x 35,680 / Frequency Span (MHz) Resolution (cm) = Distance (m) x 100 / (238 Data Points - 1) Note: Maximum Distance is 999.9
Escape Back up one menu level Exit date entry without changing the value
Power LEDs Green lit: Power on Yellow blinking: Battery pack is charging Contrast Key Press with up/down arrow keys to increase/decrease contrast
Refl Match
Secondary Measurements
Secondary Values