You are on page 1of 2

SUR Planning Software

Because of the constantly growing product range and the experience gained by us with the current software programs, we have decided to make available a new, free computer program package for the calculation of chimney cross-sections, lists of materials, and the preparation of offers, etc.

- - - Calculation of cross-sections List of materials Statistics Project administration

The SURPLAN program package has a modular structure and can be run under MICROSOFT WINDOWS. The program package comprises the following modules:

Client administration

A short description of the most important modules is provided below:

Calculation of cross-sections
Program for the calculation of chimney cross-sections according to DIN EN 13384-1 and DIN EN 13384-2

Calculations for dry and moisture-resistant chimneys and exhaust gas flues Calculations for chimneys with integrated Y-section Calculations for condensing systems on FU chimneys Print-out of all the data recorded and of the results of the calculation

Multiple configuration (DIN EN 13384-2)


Calculations for dry and moisture-resistant chimneys Up to five lines per chimney Calculations for cascades and exhaust manifolds with up to 5 heat generators Print-out of all the data recorded and of the results of the calculation

Integrated database with heat generators of SUR characteristics for chimney Provision systems and connecting pipes
Preparing offers
Program for the preparation of offers, invitations to tender, orders and delivery notes

Import of the relevant data from the module for the calculation of cross-sections Generating bills of quantity from the data from the calculation of the cross-sections and basic elements Printing offers, invitations to tender, orders and delivery notes function of the data in the GAEB format in order to ensure easy processing Export of the exported data by other programs

Subject to technical changes 1/2010

19

Software/Data collection

Simple configuration (DIN EN 13384-1)

---

SUR Data Sheet for the Calculation of Chimneys according to DIN EN 13384-1
Seibel + Reitz GmbH + Co. KG, Goldbergstrae, 35216 Biedenkopf-Breidenstein, Fax + (49) 64 61/ 8 03-63

Representative:

Wholesale:

Fax: Heating engineering company: Fax: Construction project:

Geodetic altitude above sea level ________ m

Heat generator
Manufacturer Rated output CO2 content
Software/Data collection

Full load ____ KW ____ % ____ kg/h (g/s) ____ C ____ Pa ____ mm diameter

Partial load ____ KW ____ % ____ kg/h (g/s) ____ C ____ Pa

Type

Exhaust mass flow Exhaust gas temperature

Baujahr

Req. pressure head Exhaust gas stub

Gas-blower solid fuels

Gas-atmosphere pellets

il-blower

Gas-condensing system

Oil-condensing system

Connecting piece
____ mm diameter ____ mm effective height WHV ____ mm length before bending ____ pieces of 87 bends ____ pieces of 45 bends KS-RESO-THERM Prefabricated Chimney Chimney inlet 90 Exhaust muffler yes or 45 or no

Material: stainless steel or Other _______________________

Exhaust gas system


____ m effective height WHS ____ m total height GHS
WHS

Foundation assembly

or bracket assembly or____ mm


X

Exhaust gas system

Distance from wall 50 to 100 mm On exterior of the building Roof lead-through yes If yes, roof pitch ____ Offset yes no

or inside the building


Y

Connecting piece

WHV

or no

Heat generator

Distance from wall

If yes X ____ mm / Y ____ mm


20 1/2010 Subject to technical changes