You are on page 1of 60

Construction Recommendations

Construction examples for roof, wall, floor and ceiling

Contents
General information 1. Roof
1.1 Full rafter insulation, new build 1.2 On-roof insulation, new build/reconstruction 1.3 Common rafter insulation reconstruction, from inside 1.4 Common rafter insulation reconstruction, from outside 1.4.1 Common rafter insulation reconstruction, from outside/interior panelling PB 1.4.2 Common rafter insulation reconstruction, from outside/interior panelling HWL 1.4.3 Common rafter insulation reconstruction, from outside/interior panelling for profiled wood formwork 1.5 Flat roof P. 6 P. 7 P. 8 P. 9 P. 10 P. 12 P. 14 P. 16 P. 3

2. Wall
2.1 Brickwork reconstruction, from outside 2.2 Brickwork reconstruction, from inside 2.3 Stud wall reconstruction, from outside/inside 2.4 New build brickwork insulation, from outside 2.5 Timber frame construction 2.6 Prefabricated house reconstruction 2.7 Sold timber element P. 18 P. 21 P. 22 P. 24 P. 28 P. 30 P. 32

3. Lightweight partition walls


3.1 Timber upright construction 3.2 Metal upright construction P. 36 P. 37

4. Concrete ceiling
4.1 Cement screed 4.2 Mastic asphalt 4.3 Sill plate/dry screed element 4.4 Solid wooden floor P. 38 P. 38 P. 39 S. 39

5. Beamed ceiling
Bare ceiling 5.1 Cement screed 5.2 Mastic asphalt 5.3 Sill plate/dry screed element 5.4 Solid wooden floor P. 40 P. 41 P. 42 P. 44 P. 45

6.Top floor ceiling


6.1 Concrete ceiling 6.2 Beamed ceiling P. 47 P. 47

7. Fire and noise insulation


7.1 On-roof insulation 7.2 Common rafter insulation 7.3 Exterior wall 7.4 Partition wall/party wall P. 48 P. 49 P. 50 P. 54

P. 2 GUTEX Construction Recommendations

General information
The brochure below entitled "Construction Recommendations" provides a summary of the design examples for roof, wall, floor and ceiling, with the relevant structural values for the protection against cold winter temperatures, hot summer temperatures, noise and fire.All constructions are calculated in accordance with DIN 4108 and hence tested for diffusion, moisture and condensate. Pages 48 and onwards also contain roof and wall constructions, for which fire and noise protection classifications are described. These are referred to as general building inspection certificates (AbPs). For example, exterior wall constructions classified to F90-B along with their noise protection values are stated. The result is a comprehensive work of reference, which considerably simplifies component planning. To create a failure-free construction, the manufacturer's data and/or the installation instructions for all materials used must be observed.

Insulation against the cold in winter


Thanks to their low thermal conductivity, GUTEX wood fibreboard insulation products provide outstanding protection against low winter temperatures and heat. They counteract thermal loss and inhibit the rapid cooling of living space. The benefits of thermal insulation? - Enhance living comfort through higher wall surface temperatures etc. - Improve the room conditions - Saves energy and hence cuts heating costs - Protects our environment by considerably reducing CO2 emissions - Increasing the building's value (energy certificate) Requirements for component reconstruction
Component U-factor (W/m2K) Specification EnEV 2009 Exterior wall Exterior wall insulation, from inside Steep roof Flat roof Top floor ceiling 0.24 0.35 0.24 0.20 0.24 kfwindividual measures 0.20 0.33 0.14 0.14 0.14

Insulation against the heat in summer


To prevent the living areas, especially those below the roof, from overheating, the thermal capacity of the insulating material used must dampen and delay the thermal flow from outside to inside. Because, with a specific thermal capacity of 2100 J/kgK, wood has the highest thermal capacity of all building materials, GUTEX wood fibreboard insulation products provide excellent protection against hot summer temperatures. Example Insulation with 180 mm GUTEX Thermosafe-homogen offers a phase shift (delay) of 10.0 hours. If the ambient air temperature fluctuates by 21C, as depicted in the diagram, the interior air fluctuation is 3C (amplitude damping = 7). How can we realise protection against summer temperatures? As well as the known structural influences such as position and size of the windows, air and wind tightness of the building and rear-ventilated construction, the choice of insulating material is key to summer temperature protection.

Phase shift and amplitude damping with 180 mm GUTEX Thermosafe-homogen insulation Time lag (10 hours)

Temperature profile, ambient air

Recommendations for new build For new build, the entire building envelope and the building technology is considered from an energy perspective as an integrated unit.
Component Exterior wall Steep roof/top floor ceiling Flat roof 0.16 0.16 0.14 U-factor (W/m2K) Recommendation Visionary 0.12 0.12 0.12

Temperature profile, interior air

Time Decrement

GUTEX Construction Recommendations P. 3

General information
Acoustic insulation
The requirements and recommendations are defined in DIN 4109. Components are supposed to dampen and/ or minimise the noise outside and inside the building. For noise protection, a distinction is drawn between airborne noise and impact noise. Airborne noise protection is relevant for wall and roof components, impact noise protection for floor and ceiling constructions. Floor:
Recommendations for the noise protection of ceilings within the dwelling for standard noise protection for improved noise protection Airborne noise RW 50 dB RW 55 dB Impact noise Ln,w 57 dB Ln,w 46 dB

Airborne noise protection:


The specific variable is the airborne noise factor R in dB. The higher the singular value, the more effective the airborne noise insulation. The characteristics of high raw density, low flexural strength and porous fibre structure exhibited by GUTEX fibreboard insulation products guarantee a high degree of noise absorption and hence optimised noise protection!

Requirements and recommendations for the noise protection partition ceilings in apartment buildings Airborne noise Impact noise Ln,w 53 dB from DIN 4109 RW 54 dB for improved noise protection from supplement 2 DIN 4109 RW 55 dB Ln,w 46 dB

Airborne noise protection:


The specific variable is the impact noise insulation factor L in dB. The lower the singular value, the more effective the impact noise insulation. Board characteristics essential to impact noise protection are weight, flexural strength, dynamic strength and decoupling. For noise insulation, a distinction is drawn between noise transmission through the component with and without byways.

Interior walls: Requisite airborne noise insulation for protection against noise transmission from an external living and working area
Components Multi-story buildings with apartments and offices Partition walls and walls between external work areas Staircase walls and walls next to the building corridors Walls next to thoroughfares In hospitals: - Walls between patients' rooms - Corridors and patients' rooms - Examination rooms - Consultation rooms Schools: walls between classrooms Walls between classrooms and staircases emp. Rw in dB 53 52 55

Requirements and recommendations


Exterior wall/steep roof:
Requirements for the airborne noise insulation of exterior components Noise level range Significant Wards in outside noise infirmaries level dB (A) I II III IV V VI VII up to 55 55 - 60 61 - 65 66 - 70 71 - 75 76 - 80 > 80 35 35 40 45 50
2) 2)

47

Common Offices etc. 1) rooms in apartments etc. 30 30 35 40 45 50


2)

47 52

emp. Rw,res of the structural part in dB 30 30 35 40 45 50

Pleasant indoor environment


GUTEX wood fibreboard insulation products are permeable ( = 3) and control air humidity by absorbing and subsequently emitting up to 15 %, depending on the room conditions, of the board weight in humidity, without losing the insulating effect. The combination of these two characteristics positively effects the room conditions.

1) No requirements are placed on exterior components of exterior rooms, where the penetrating outside noise, due to the activities being carried out inside the rooms, make only a secondary contribution to the inside noise level. 2) The requirements must be set out here on account of the local conditions.

Correction values for the requisite noise insulation factor Rw,res of the exterior component depending on the condition of the component surface S (W+F) for the ground area of the room S(G) S (W+F) / S(G) Correction value 2.5 +5 dB 2.0 +4 dB 1.6 +3 db 1.3 +2 dB 1.0 +1 dB 0.8 0 dB 0.6 -1 dB 0.5 -2 dB 0.4 -3 dB

Semi-detached houses and terraced houses Recommendations for improved noise protection Partition walls

emp. RW (dB) 57

P. 4 GUTEX Construction Recommendations

Fire protection
GUTEX understands fire safety as protection for people and animals against fire. Fire safety, however, also means minimising the resultant damage. The requirements for building fire safety are regulated by the countries concerned. There are two distinctly different requirements. One is the building material class or its fire behaviour and the other is the fire resistance class of a component. Building material classes or fire behaviour fall into classes A = "nonflammable" to F = "highly-flammable". For the construction industry, however, the minimum requirement is Class B2 = "normally flammable" (Germany) or Class E = "normally flammable" (Europe). Testing institutes conduct flammability tests on building productions and classify them accordingly. Fire resistance falls into classes F 30 F180.The classification is in turn carried out by testing institutes and the product is certified accordingly. In this case, it is not the product that is classified but an entire component. F 30 means, for example, that a component will withstand fire for 30 minutes without structural failure or burn through. This guarantees that a construction in this category offers, in case of fire, 30 minutes to move people and animals out of the hazard zones.

Environmental compatibility
In the case of an ecological insulating material, the principle of sustainability over the entire life cycle, from production to processing and use, through to disposal should be the top priority. All trees bind, during their lifetime, the same amount of CO2, which they emit into the environment when they rot or are burned. Because GUTEX soft board is made from woodchip that occurs as a byproduct in the saw mill, it contains CO2, which is not emitted into the atmosphere as a greenhouse gas. GUTEX obtains the woodchip from the saw mills surrounding its Waldshut-Tiengen site in the south of the Black Forest. Other plus factors in the eco-balance are wood from sustainable forests and short supplier transport routes . Unless contaminated by foreign material, GUTEX softboard can be recycled at the end of its utilisation pathway . GUTEX products carry the quality mark "natureplus". The tough criteria that have to be met for the "natureplus" to be awarded are reviewed annually by the umbrella association of environmental organisations, institutes, construction biologists, companies and associations. The basic criteria for the award are high technical product quality completely harmless to health environmentally compatible production sustainability of the raw materials used

Fire safety structures


Various components are classified in the AbPs (general building inspection certificates) below. The numerous structural variants simplifies planning procedures and the associated fulfillment of fire safety requirements. AbP P-SAC 02/III-370: On-roof insulation and common rafter insulation in fire resistance classes F30-B to F90-B with GUTEX Thermosafe-homogen, GUTEX Thermoflex and GUTEX Multiplex-top/Ultratherm. AbP P-SAC 02/III-321: Supporting, enclosing exterior wall in fire resistance classes F30-B to F90-B with GUTEX Thermowall/-gf and GUTEX Multiplex-top/Ultratherm. AbP P-172 34405-ift: Partition wall in class F90-B and a noise protection requirement of min. R`w = 57 dB.

User friendly
Gutex insulating board exhibits extremely narrow dimensional tolerances and is produced to tough quality standards. This, coupled with detailed instructions makes for simple processing.

Made in Germany
For almost 80 years now, "GUTEX Holzfaserplattenwerk", a family-owned enterprise based in the Black Forest has been producing wood fibreboard insulation products at its Waldshut-Tiengen plant in the south of the area. All GUTEX insulating board carries the CE and marks is produced to the specified standard. The composite thermal insulation system from GUTEX is also approved by the building authorities.

Recyclability
GUTEX wood fibreboard is recyclable and can, unless contaminated by wood preservatives, be returned for reuse.

GUTEX Construction Recommendations P. 5

1. Roof

1.1 Full rafter insulation new build

1.1.1 Structure:
- Tile battens - Counter battens - GUTEX Multiplex-top - GUTEX Thermofibre/GUTEX Thermoflex between the rafters - Vapour barrier/air seal - Battens - Facing GUTEX Thermofibre/ Thermoflex (mm) 180 22 200 220 240 180 28 200 220 240 180 35 200 220 240 Noise insulation value RW, R (dB) 2) 48

1.1.2 Structure:
- Tile battens - Counter battens - GUTEX Ultratherm - GUTEX Thermofibre/GUTEX Thermoflex between the rafters - Vapour barrier/air seal - Battens - Facing GUTEX Thermofibre/ Thermoflex (mm) 180 200 220 240 60 180 200 220 240 180 200 220 240 180 200 220 240 120 180 200 220 240 180 200 220 240 180 200 220 240 Noise insulation value RW, R (dB) 2) 46

GUTEX Multiplextop (mm)

U-factor (W/m2K)1) 0.22 0.20 0.18 0.17 0.21 0.19 0.18 0.17 0.20 0.19 0.17 0.16

Phase shift (h) 9.5 10.2 11.0 11.7 10.0 10.7 11.4 12.1 10.5 11.2 11.9 12.7

GUTEX Ultratherm (mm)

U-factor (W/m2K)1) 0.19 0.17 0.16 0.15 0.18 0.17 0.16 0.15 0.16 0.15 0.14 0.14 0.15 0.14 0.13 0.13 0.14 0.13 0.13 0.12 0.13 0.13 0.12 0.11 0.12 0.12 0.11 0.11

Phase shift (h) 11.6 12.3 13.1 13.8 12.4 13.1 13.8 14.6 13.9 14.6 15.3 16.1 15.3 16.0 16.8 17.5 16.7 17.4 18.1 18.9 18.1 18.8 19.5 20.2 19.4 20.2 20.9 21.6

50 47 48 49 47 48 100 80

47

48

49

50

140

50

160

50

1) Calculation with 10 % wood content 2) The noise levels refer to a construction with GUTEX Thermoflex, a roof covering with concrete roofing tiles and double-threaded bolt fastening

P. 6 GUTEX Construction Recommendations

1.2 On-roof insulation, new build/reconstruction

1.2.1 Structure:
- Tile battens - Counter battens - GUTEX Multiplex-top/GUTEX Ultratherm - GUTEX Thermosafe-homogen - Vapour barrier/air seal - Exposed formwork 24 mm - Exposed rafters

1.2.2 Structure:
- Tile battens - Counter battens - GUTEX Multiplex-top/GUTEX Ultratherm - GUTEX Thermofibre between double I-joists - Vapour barrier/air seal - Exposed formwork 24 mm - Exposed rafters

Thickness (mm)

GUTEX Thermosafe- U-factor1) homogen (W/m2K) (mm) 140 160 180 200 220 240 140 160 180 200 220 240 200 220 240 200 220 240 200 220 240 200 220 240 200 220 200 0.22 0.20 0.18 0.16 0.15 0.14 0.22 0.19 0.18 0.16 0.15 0.14 0.16 0.14 0.13 0.15 0.14 0.13 0.14 0.13 0.12 0.14 0.13 0.12 0.13 0.12 0.12

Phase shift (h) 11.7 12.9 14.0 15.2 16.4 17.5 12.0 13.2 14.3 15.5 16.6 17.8 15.9 17.1 18.2 16.4 17.6 18.7 17.5 18.6 19.8 18.2 19.4 20.5 19.7 20.8 21.1

Noise insulation value RW, R (dB)2) 46 46 47 47 48 48 46 46 47 47 48 48 47 48 48 47 48 48 46 48 48 46 48 48 46 48 46

Thickness (mm)

GUTEX Thermofibre (mm) 200

U-factor 1) (W/m2K) 0.17 0.15 0.14 0.16 0.15 0.14 0.15 0.14 0.13 0.15 0.14 0.13 0.14 0.13 0.12 0.13 0.12 0.11

Phase shift (h) 10.8 11.4 12.0 11.3 11.9 12.6 12.5 13.1 13.7 13.3 13.9 14.5 14.8 15.4 16.0 16.2 16.8 17.5

28 GUTEX Multiplex-top 35

220 240 200 220 240 200 220 240 200

18

GUTEX Multiplextop

22

28

60 GUTEX Ultratherm 80

220 240 200 220 240 200

35

50 GUTEX Ultratherm

100

220 240

60 80 100

1) Calculation with 10 % wood content 2) The noise levels refer to a construction with GUTEX Thermoflex, a roof covering with concrete roofing tiles and double-threaded bolt fastening

GUTEX Construction Recommendations P. 7

Roof

1. Roof

1. Roof

1.3 Reconstruction, from inside

1.3.1 Common rafter insulation Structure:


- Existing tile battens - Existing counter battens - Existing formwork with bitumen sheeting 26 mm - GUTEX Thermofibre/GUTEX Thermoflex between the rafters - GUTEX Multitherm with groove and spring - Vapour barrier/air seal, moisture variable - Battens - Facing GUTEX GUTEX Thermofibre/ Multitherm Thermoflex (mm) (mm) 20 160 180 140 40 160 180 200 120 140 60 160 180 200 120 140 80 160 180 200 120 140 100 160 180 200 120 140 120 160 180 200 Noise insulation value RW, R (dB) 2)

1.3.2 Common rafter insulation Structure:


- Existing tile battens - Battens on rafters - GUTEX Multiplex-top 22 mm between the rafters - GUTEX Thermofibre/GUTEX Thermoflex between the rafters - OSB board 15 mm - GUTEX Thermoroom - Loam rendering layer 15 mm

U-factor (W/m2K) 1) 0.23 0.21 0.22 0.20 0.19 0.17 0.22 0.20 0.18 0.17 0.16 0.20 0.18 0.17 0.16 0.15 0.18 0.16 0.15 0.14 0.14 0.16 0.15 0.14 0.13 0.13

Phase shift (h) 9.8 10.5 10.2 10.9 11.6 12.3 10.7 11.4 12.1 12.8 13.5 11.9 12.6 13.3 14.0 14.8 13.2 13.9 14.6 15.3 16.0 14.5 15.2 15.9 16.6 17.3

GUTEX Thermoroom (mm)

GUTEX Thermofibre/ Thermoflex (mm) 120 140

U-factor 1) (W/m2K) 0.23 0.21 0.19 0.17 0.16 0.22 0.20 0.19 0.17 0.16 0.15 0.22 0.20 0.18 0.17 0.16 0.15 0.14 0.19 0.18 0.17 0.15 0.14 0.14 0.13

Phase shift (h) 12.5 13.2 13.9 14.6 15.3 13.2 13.8 14.4 15.1 15.8 16.6 13.7 14.3 15.0 15.6 16.3 17.0 17.7 14.9 15.5 16.1 16.8 17.5 18.2 18.9

Noise insulation value RW, R (dB) 2)

40

160 180 200 100 120 140 160 180 200 80

60

49 80

100 120 140 160 180 200 80 100 120 100 140 160 180 200

46

1) Calculation with 10 % wood content 2) Values as per "Informationsdienst Holz", series 3, part 3, sequence 4, RW , R = calculated value, incl. allowance

P. 8 GUTEX Construction Recommendations

1.3 Reconstruction, from inside/ 1.4 Reconstruction, from outside


1.4 Reconstruction, from outside Important information:

GUTEX systematic roof reconstruction


The following reconstruction variants from outside can be executed only using the membranes from the following GUTEX system partners: Proclima, membrane Solitex UD and Solitex UD connect 1.3.3 Common rafer insulation Structure:
- Existing tile battens - Battens on rafters - GUTEX Multiplex-top 22 mm - GUTEX Thermofibre/GUTEX Thermoflex between the rafters - GUTEX Multitherm with groove and spring - Vapour barrier/air seal - Battens - Facing GUTEX GUTEX Thermofibre/ Multitherm Thermoflex (mm) (mm) 120 140 160 180 200 100 120 140 160 180 200 80 100 120 140 160 180 200 80 100 120 140 160 180 200 80 100 120 140 160 180 200 U-factor 1) (W/m2K) 0.23 0.21 0.19 0.18 0.17 0.23 0.21 0.19 0.18 0.16 0.15 0.22 0.20 0.19 0.17 0.16 0.15 0.14 0.20 0.18 0.17 0.16 0.15 0.14 0.13 0.18 0.17 0.16 0.15 0.14 0.13 0.12 Phase shift (h) 9.5 10.1 10.8 11.6 12.3 10.0 10.6 11.3 12.0 12.8 13.5 10.6 11.2 11.9 12.6 13.3 14.0 14.7 11.8 12.5 13.2 13.8 14.6 15.3 16.0 13.1 13.7 14.4 15.1 15.8 16.6 17.3 Noise insulation value RW, R (dB) 2)

Ampack, membrane Ampatop Protecta und Ampatop Protecta plus Isocell, membranes OMEGA MONO 200 and OMEGA LIGHT CaPlast, membranes CaTop M 170 and CaTop M 120 Frch, membrane Saniflex 002 Saint Gobain, membranes NOVIPro UDB 310/-SK and NOVIPro UDB 210/-SK BWK, membranes Difflex Thermo ND; REWASI TOP 130 and REWASI TOP 150 Raab Karcher, membrane NOVIPro Alujet, membranes JKE Basic and JKE Professional

40

The insulation thickness ratios described in the relevant tables must be respected.

60

When using air-tight interior panelling, the air-tight membrane is not required.

80

47

100

120

1) Calculation with 10 % wood content 2) Values as per "Informationsdienst Holz", series 3, part 3, sequence 4, RW , R = calculated value, incl. allowance

GUTEX Construction Recommendations P. 9

Roof

1. Roof

1. Roof

1.4.1 Reconstruction, from outside

1.4.1.1 Internal panelling, plasterboard Structure:


- Tile battens - Counter battens - GUTEX Ultratherm - Air-tight membrane in accordance with GUTEX system partner - GUTEX Thermofibre3)/GUTEX Thermoflex between the rafters - Existing battens - PB/PF 12.5 mm

1.4.1.2 Interior panelling, plasterboard Structure:


- Tile battens - Counter battens - GUTEX Ultratherm - Air-tight membrane* in accordance with GUTEX system partner - Mineral wool 035 between the rafters - Existing battens - PB/PF 12.5 mm

GUTEX GUTEX Noise insulation Thermofibre/ U-factor Ultratherm Phase shift (h) value 2 1) Thermoflex (W/m K) (mm) RW, R (dB) 2) (mm) 140 0.22 10.2 160 0.20 10.9 50 47 180 0.19 11.6 200 0.17 12.3 120 0.23 10.3 140 0.21 11.0 60 160 0.19 11.7 47 180 0.18 12.4 200 0.17 13.1 120 0.21 11.8 140 0.19 12.5 80 160 0.18 13.2 47 180 0.16 13.9 200 0.15 14.6 120 0.19 13.2 140 0.18 13.9 100 160 0.16 14.6 48 180 0.15 15.3 200 0.14 16.0 120 0.17 14.6 140 0.16 15.3 120 160 0.15 16.0 49 180 0.14 16.7 200 0.13 17.4 120 0.16 15.9 140 0.15 16.6 140 160 0.14 17.4 49 180 0.13 18.1 200 0.13 18.8 120 0.15 17.3 140 0.14 18.0 160 160 0.13 18.7 50 180 0.12 19.4 200 0.12 20.2

GUTEX Ultratherm (mm) 50 60

Mineral wool 035 (mm) 120 120 140 160 120 140 160 180 120 140 160 180 200 120 140 160 180 200 120 140 160 180 200 120 140 160 180 200

U-factor (W/m2K) 1) 0.24 0.22 0.20 0.19 0.20 0.18 0.17 0.16 0.18 0.17 0.16 0.15 0.14 0.17 0.16 0.15 0.14 0.13 0.16 0.15 0.14 0.13 0.12 0.15 0.14 0.13 0.12 0.11

Phase shift (h) 8.1 8.9 9.2 9.6 10.4 10.8 11.2 11.5 11.9 12.3 12.6 13.0 13.3 13.3 13.6 14.0 14.4 14.7 14.6 15.0 15.4 15.7 16.1 16.0 16.4 16.7 17.1 17.4

Noise insulation value RW, R (dB) 2) 47 47

80

47

100

48

120

49

140

49

160

50

*Note: With this construction, the sd-value for the air-tight membrane must not exceed 0.03m.

1) Calculation with 10 % wood content 2) Values as per "Informationsdienst Holz", series 3, part 3, sequence 4, RW , R = calculated value, incl. allowance 3) When using GUTEX Thermofibre, air-tight interior panelling must be produced

P. 10 GUTEX Construction Recommendations

1.4.1 Reconstruction, from outside

1.4.1.3 Interior panelling, plasterboard Structure:


- Tile battens - Counter battens - GUTEX Multiplex-top/ Ultratherm - Air-tight membrane in accordance with GUTEX system partner - GUTEX Thermoflex between the rafters - Existing mineral wool with aluminium lining - Existing battens - PB/PF 12.5 mm

1.4.1.4 Internal panelling, plasterboard Structure:


- Tile battens - Counter battens - GUTEX Ultratherm - Air-tight membrane in accordance with GUTEX system partner - GUTEX Thermoflex between the rafters - Existing mineral wool with aluminium lining - Existing battens - PB/PF 12.5 mm

U-factor in (W/mK)1), phase shift in hours (h)


Existing GUTEX MW WLZ Thermoflex (mm) 040 (mm) GUTEX Multiplex-top (mm) 35 0.28 7.6 0.25 8.3 0.23 9.0 0.21 9.8 0.28 7.2 0.25 7.9 0.23 8.7 0.21 9.4 0.19 10.1 0.25 7.5 0.23 8.2 0.21 9.0 0.19 9.7 0.23 7.8 0.21 8.5 0.19 9.3 GUTEX Ultratherm (mm) 50 0.25 8.7 0.23 9.4 0.21 10.1 0.19 10.9 0.25 8.3 0.23 9.1 0.21 9.8 0.19 10.5 0.18 11.3 0.23 8.7 0.21 9.4 0.19 10.1 0.18 10.9 0.21 9.0 0.19 9.7 0.18 10.4 60 0.24 9.5 0.21 10.2 0.20 10.9 0.18 11.7 0.24 9.1 0.22 9.8 0.20 10.6 0.18 11.3 0.17 12.0 0.22 9.5 0.20 10.2 0.18 10.9 0.17 11.6 0.20 9.8 0.18 10.5 0.17 11.2 80 0.21 11.0 0.19 11.7 0.18 12.4 0.17 13.1 0.21 10.6 0.19 11.3 0.18 12.1 0.17 12.8 0.16 13.5 0.20 11.0 0.18 11.7 0.17 12.4 0.16 13.1 0.18 11.3 0.17 12.0 0.16 12.7

U-factor in (W/mK)1), phase shift in hours (h)


Existing MW WLZ 040 (mm) GUTEX Thermoflex (mm) 60 80 60 100 120 40 60 80 80 100 120 40 60 100 80 100 40 120 60 80 100 0.19 12.4 0.18 13.1 0.16 13.8 0.15 14.6 0.19 12.1 0.18 12.8 0.17 13.5 0.15 14.2 0.14 14.9 0.18 12.4 0.17 13.1 0.15 13.8 0.14 14.6 0.17 12.7 0.15 13.4 0.15 14.1 GUTEX Ultratherm (mm) 120 0.18 13.8 0.16 14.5 0.15 15.2 0.14 15.9 0.18 13.4 0.16 14.1 0.15 14.9 0.14 15.6 0.13 16.3 0.16 13.8 0.15 14.5 0.14 15.2 0.14 15.9 0.15 14.1 0.14 14.8 0.14 15.5 140 0.16 15.2 0.15 15.9 0.14 16.6 0.13 17.3 0.16 14.8 0.15 15.5 0.14 16.2 0.13 17.0 0.13 17.7 0.15 15.2 0.14 15.9 0.13 16.6 0.13 17.3 0.14 15.5 0.13 16.2 0.13 16.9 160 0.15 16.5 0.14 17.2 0.13 18.0 0.13 18.7 0.15 16.2 0.14 16.9 0.13 17.6 0.13 18.3 0.12 19.1 0.14 16.5 0.13 17.2 0.13 18.0 0.12 18.7 0.13 16.8 0.13 17.5 0.12 18.3

60 80 60 100 120 40 60 80 80 100 120 40 60 100 80 100 40 120 60 80

1) Calculation with 10 % wood content

GUTEX Construction Recommendations P. 11

Roof

1. Roof

1. Roof

1.4.2 Reconstruction, from outside

1.4.2.1 Interior panelling HWL board Structure:


- Tile battens - Counter battens - GUTEX Ultratherm - Air-tight membrane in accordance with GUTEX system partner - GUTEX Thermofibre3)/GUTEX Thermoflex between the rafters - Existing battens - HWL board 25 mm - Plaster 15 mm GUTEX GUTEX Noise insulaU-factor1) Phase shift Ultratherm Thermofibre/ tion value 2 (W/m K) (h) (mm) Thermoflex (mm) RW, R (dB) 2) 120 140 160 180 200 120 140 160 180 200 120 140 160 180 200 120 140 160 180 200 120 140 160 180 200 120 140 160 180 200 120 140 160 180 200 0.23 0.21 0.19 0.18 0.17 0.22 0.20 0.19 0.17 0.16 0.20 0.18 0.17 0.16 0.15 0.18 0.17 0.16 0.15 0.14 0.17 0.16 0.15 0.14 0.13 0.15 0.14 0.14 0.13 0.12 0.14 0.14 0.13 0.12 0.11 11.2 11.9 12.6 13.3 14.0 12.0 12.7 13.4 14.1 14.8 13.5 14.2 14.9 15.6 16.3 14.9 15.6 16.3 17.0 17.7 16.3 17.0 17.7 18.4 19.1 17.7 18.3 19.0 19.7 20.5 19.0 19.7 20.4 21.1 21.8

1.4.2.2 Interior panelling HWL board Structure:


- Tile battens - Counter battens - GUTEX Ultratherm - Air-tight membrane in accordance with GUTEX system partner - Mineral wool 035 between the rafters - Existing battens - HWL board 25 mm - Plaster 15 mm GUTEX Ultratherm (mm) Mineral wool 035 (mm) 120 140 160 180 200 120 140 160 180 200 120 140 160 180 200 120 140 160 180 200 120 140 160 180 200 120 140 160 180 200 120 140 160 180 200 U-factor (W/m2K) 1) 0.22 0.20 0.19 0.17 0.16 0.21 0.19 0.18 0.16 0.15 0.19 0.18 0.16 0.15 0.14 0.18 0.16 0.15 0.14 0.13 0.16 0.15 0.14 0.13 0.12 0.15 0.14 0.13 0.12 0.12 0.14 0.13 0.12 0.12 0.11 Phase shift (h) 9.6 9.9 10.2 10.5 10.8 10.5 10.7 11.0 11.3 11.7 12.0 12.3 12.6 12.9 13.3 13.5 13.8 14.1 14.4 14.7 14.9 15.2 15.5 15.8 16.1 16.2 16.5 16.8 17.1 17.5 17.6 17.9 18.2 18.5 18.8 Noise insulation value RW, R (dB) 2)

50

47

50

47

60

47

60

47

80

47

80

47

100

48

100

48

120

49

120

49

140

49

140

49

160

50

160

50

1) Calculation with 10 % wood content 2) Values in accordance with "Informationsdienst Holz", series 3, part 3, sequence 4, RW , R = calculated value incl. allowance 3) When using GUTEX Thermofibre, air-tight interior panelling must be produced

P. 12 GUTEX Construction Recommendations

1.4.2 Reconstruction, from outside

1.4.2.3 Interior panelling HWL board Structure:


- Tile battens - Counter battens - GUTEX Multiplex-top/ Ultratherm - Air-tight membrane in accordance with GUTEX system partner - GUTEX Thermoflex between the rafters - Existing mineral wool with aluminium lining - Existing battens - HWL board 25 mm - Plaster 15 mm

1.4.2.4 Interior panelling HWL board Structure:


- Tile battens - Counter battens - GUTEX Ultratherm - GUTEX Thermoflex between the rafters - Air-tight membrane in accordance with GUTEX system partner - Existing mineral wool with aluminium lining - Existing battens - HWL board 25 mm - Plaster 15 mm

U-factor in (W/mK)1), phase shift in hours (h)


Existing GUTEX MW WLZ Thermo040 flex (mm) (mm) GUTEX Multiplextop (mm) 35 40 60 80 80 100 120 40 60 100 80 100 40 120 60 80 0.26 8.9 0.24 9.6 0.21 10.3 0.20 11.0 0.18 11.7 0.24 9.1 0.21 9.8 0.20 10.5 0.18 11.3 0.22 9.4 0.20 10.0 0.18 10.6 50 0.24 10.0 0.22 10.7 0.20 11.4 0.18 12.1 0.17 12.9 0.22 10.3 0.20 11.0 0.18 11.7 0.17 12.4 0.20 10.5 0.18 11.2 0.17 11.9 GUTEX Ultratherm (mm) 60 0.22 10.8 0.20 11.5 0.19 12.2 0.17 12.9 0.16 13.6 0.21 11.1 0.19 11.8 0.17 12.5 0.16 13.2 0.19 11.3 0.17 12.0 0.16 12.7 80 0.20 12.4 0.19 13.0 0.17 13.7 0.16 14.4 0.15 15.1 0.19 12.6 0.17 13.3 0.16 14.0 0.15 14.7 0.17 12.9 0.16 13.5 0.15 14.2

U-factor in (W/mK)1), phase shift in hours (h)


GUTEX Existing ThermoMW WLZ flex 040 (mm) (mm) 100 40 60 80 80 100 120 40 60 100 80 100 40 120 60 80 0.18 13.8 0.17 14.4 0.16 15.1 0.15 15.8 0.14 16.6 0.17 14.0 0.16 14.7 0.15 15.4 0.14 16.1 0.16 14.3 0.15 14.9 0.14 15.7 GUTEX Ultratherm (mm) 120 0.17 15.2 0.16 15.8 0.15 16.5 0.14 17.2 0.13 17.9 0.16 15.4 0.15 16.1 0.14 16.8 0.13 17.5 0.15 15.7 0.14 16.3 0.13 17.0 140 0.16 16.6 0.15 17.2 0.14 17.9 0.13 18.6 0.12 19.3 0.15 16.8 0.14 17.5 0.13 18.2 0.12 18.9 0.14 17.0 0.13 17.7 0.12 18.4 160 0.15 17.9 0.14 18.6 0.13 19.3 0.12 20.0 0.12 20.7 0.14 18.2 0.13 18.8 0.12 19.5 0.12 20.2 0.13 18.4 0.12 19.1 0.12 19.8

1) Calculation with 10 % wood content 2) Values as per "Informationsdienst Holz", series 3, part 3, sequence 4, RW , R = calculated value, incl. allowance

GUTEX Construction Recommendations P. 13

Roof

1. Roof

1. Roof

1.4.3 Reconstruction, from outside

1.4.3.1 Interior panelling, profiled wood formwork Structure:


- Tile battens - Counter battens - GUTEX Ultratherm - Air-tight membrane in accordance with GUTEX system partner - GUTEX Thermofibre3)/GUTEX Thermoflex between the rafters - Profiled wood formwork min. 10 mm

1.4.3.2 Interior panelling, profiled wood formwork Structure:


- Tile battens - Counter battens - GUTEX Ultratherm - Air-tight membrane in accordance with GUTEX system partner - Mineral wool 035 - Profiled wood formwork min. 10 mm

GUTEX GUTEX Thermofibre/ Ultratherm Thermoflex (mm) (mm) 140 160 50 180 200 120 140 60 160 180 200 120 140 80 160 180 200 120 140 100 160 180 200 120 140 120 160 180 200 120 140 140 160 180 200 120 140 160 160 180 200

U-factor (W/m2K)1) 0.22 0.20 0.19 0.17 0.23 0.21 0.19 0.18 0.16 0.21 0.19 0.18 0.16 0.15 0.19 0.17 0.16 0.15 0.14 0.17 0.16 0.15 0.14 0.13 0.16 0.15 0.14 0.13 0.12 0.15 0.14 0.13 0.12 0.12

Phase shift (h) 10.7 11.4 12.2 12.9 10.8 11.5 12.2 12.9 13.7 12.3 13.0 13.7 14.4 15.2 13.7 14.4 15.1 15.9 16.6 15.1 15.8 16.5 17.2 18.0 16.5 17.2 17.9 18.6 19.3 17.9 18.6 19.3 20.0 20.7

Noise insulation value RW , R dB 2) < 47

< 47

< 47

< 48

< 49

< 49

< 50

GUTEX Mineral wool Ultratherm 035 (mm) (mm) 120 140 160 50 180 200 120 140 160 60 180 200 120 140 80 160 180 200 120 140 100 160 180 200 120 140 120 160 180 200 120 140 140 160 180 200 120 140 160 160 180 200

U-factor (W/m2K)1) 0.23 0.21 0.19 0.18 0.16 0.22 0.20 0.18 0.17 0.16 0.20 0.18 0.17 0.16 0.15 0.18 0.17 0.16 0.14 0.14 0.17 0.15 0.14 0.14 0.13 0.15 0.14 0.13 0.13 0.12 0.14 0.13 0.13 0.12 0.11

Phase shift (h) 8.6 8.9 9.2 9.6 9.9 9.4 9.8 10.1 10.4 10.7 11.0 11.3 11.7 12.0 12.3 12.4 12.8 13.1 13.4 13.8 13.8 14.2 14.5 14.8 15.1 15.2 15.5 15.9 16.2 16.5 16.6 16.9 17.2 17.6 17.9

Noise insulation value RW , R dB 2)

< 47

< 47

< 47

< 48

< 49

< 49

< 49

1) Calculation with 10 % wood content 2) Values in accordance with "Informationsdienst Holz", series 3, part 3, sequence 4, RW , R = calculated value incl. allowance 3) When using GUTEX Thermofibre, air-tight interior panelling must be produced

P. 14 GUTEX Construction Recommendations

1.4.3 Reconstruction, from outside

1.4.3.3 Interior panelling, profiled wood formwork Structure:


- Tile battens - Counter battens - GUTEX Multiplex-top/ Ultratherm - Air-tight membrane in accordance with GUTEX system partner - GUTEX Thermoflex between the rafters - Existing mineral wool with aluminium lining - Profiled wood formwork min. 10 mm

1.4.3.4 Interior panelling, profiled wood formwork Structure:


- Tile battens - Counter battens - GUTEX Ultratherm - Air-tight membrane in accordance with GUTEX system partner - GUTEX Thermoflex between the rafters - Existing mineral wool with aluminium lining - Profiled wood formwork min. 10 mm

U-factor in (W/mK)1), phase shift in hours (h)


Existing MW GUTEX GUTEX WLZ 040 Thermoflex Multiplex-top (mm) (mm) (mm) 35 40 60 80 80 100 120 40 60 100 80 100 40 120 60 80
1) Calculation with 10 % wood content

U-factor in (W/mK)1), phase shift in hours (h)


Existing MW WLZ 040 (mm) GUTEX Thermoflex (mm) 100 40 60 80 80 100 120 40 60 100 80 100 40 120 60 80 0.19 12.7 0.18 13.4 0.16 14.1 0.15 14.8 0.14 15.5 0.18 13.0 0.16 13.7 0.15 14.4 0.14 15.1 0.16 13.3 0.15 14.0 0.14 14.7 GUTEX Ultratherm (mm) 120 0.17 14.1 0.16 14.8 0.15 15.5 0.14 16.2 0.13 16.9 0.16 14.4 0.15 15.1 0.14 15.8 0.13 16.5 0.15 14.7 0.14 15.3 0.13 16.0 140 0.16 15.5 0.15 16.1 0.14 16.8 0.13 17.5 0.13 18.3 0.15 15.8 0.14 16.4 0.13 17.1 0.13 17.9 0.14 16.0 0.13 16.7 0.13 17.4 160 0.15 16.8 0.14 17.5 0.13 18.2 0.12 18.9 0.12 19.6 0.14 17.1 0.13 17.8 0.13 18.5 0.12 19.2 0.13 17.4 0.13 18.1 0.12 18.8

GUTEX Ultratherm (mm) 50 0.25 9.0 0.22 9.7 0.20 10.4 0.19 11.1 0.17 11.8 0.22 9.2 0.20 9.9 0.19 10.7 0.17 11.4 0.21 9.5 0.19 10.2 0.17 10.9 60 0.23 9.8 0.21 10.4 0.19 11.2 0.18 11.9 0.17 12.6 0.21 10.0 0.20 10.7 0.18 11.5 0.17 12.2 0.20 10.3 0.18 11.0 0.17 11.7 80 0.21 11.3 0.19 12.0 0.18 12.7 0.16 13.4 0.15 14.1 0.19 11.6 0.18 12.3 0.17 13.0 0.15 13.7 0.18 11.8 0.17 12.5 0.15 13.2

0.28 7.9 0.25 8.5 0.22 9.2 0.20 9.9 0.19 10.7 0.25 8.1 0.22 8.8 0.20 9.5 0.19 10.3 0.22 8.4 0.20 9.1 0.19 9.8

GUTEX Construction Recommendations P. 15

Roof

1. Roof

1. Flat roof

1.5 New build/reconstruction

1.5.1 Open beam position Structure:


- Membrane seal - GUTEX Thermoflat - Air seal/vapour barrier, moisture variable - Exposed formwork 30 mm - Exposed beam position

1.5.2 Solid wood ceiling Structure:


- Membrane seal - GUTEX Thermoflat - Air seal/vapour barrier, moisture variable - Solid wood ceiling element 130 mm

GUTEX Thermoflat (mm) 200* 220* 240* 260* 280*


* double-layer installation

U-factor (W/m2K) 0.18 0.17 0.15 0.14 0.13

Phase shift (h) 15.6 16.9 18.1 19.4 20.7

GUTEX Thermoflat (mm) 200* 200* 220* 240* 260* 280*

U-factor (W/m2K) 0.19 0.16 0.15 0.14 0.13 0.12

Phase shift (h) 19.0 21.6 22.9 24.1 25.4 26.6

Note: Customised tapered insulation can be requested and supplied.

P. 16 GUTEX Construction Recommendations

1.5 New build/reconstruction

1.5.3 Concrete Structure:


- Membrane seal - GUTEX Thermoflat - Sealing membrane - Concrete 140 mm

1.5.4 Steel plate Structure:


- Membrane seal - GUTEX Thermoflat - Sealing membrane - Steel plate

GUTEX Thermoflat (mm) 200* 220* 240* 260* 280*


* double-layer installation

U-factor (W/m2K) 0.19 0.17 0.16 0.14 0.13

Phase shift (h) 16.7 18.0 19.2 20.5 21.8

GUTEX Thermoflat (mm) 200* 220* 240* 260* 280*

U-factor (W/m2K) 0.19 0.17 0.16 0.15 0.14

Phase shift (h) 12.8 14.1 15.3 16.6 17.9

Note: Customised tapered insulation can be requested and supplied.

GUTEX Construction Recommendations P. 17

Roof

1. Flat roof

2. Exterior wall

2.1 Brickwork reconstruction, from outside.

2.1.1 Rear-ventilated facade Structure:


- Existing plaster coating - Existing brickwork 24 cm 1) - Existing plaster coating - GUTEX Multitherm - Water-carrying, UV-resistant, permeable membrane - Counter battens - Joint formwork

2.1.2 Rear-ventilated facade Structure:


- Existing plaster coating - Existing brickwork 24 cm 1) - Existing plaster coating - GUTEX Thermosafe-homogen - GUTEX Multitherm - Counter battens - Wood formwork, closed

GUTEX Multitherm (mm) 40 60 80 100 120 140 160

U-factor (W/m2K) 0.64 0.48 0.39 0.32 0.28 0.24 0.22

Phase shift (h) 12.5 13.3 14.3 15.4 16.7 17.9 19.2

GUTEX Thermosafehomogen (mm) 100 120 140 160 180 200 220 240 240 240

GUTEX Multitherm (mm) 20 20 20 20 20 20 20 20 40 60

U-factor (W/m2K) 0.27 0.23 0.21 0.19 0.17 0.15 0.14 0.13 0.12 0.12

Phase shift (h) 16.1 17.3 18.4 19.6 20.7 21.9 23.1 24.2 25.5 26.8

1) Assumed

value = 0.70 W/mK

P. 18 GUTEX Construction Recommendations

2. Exterior wall

2.1 Brickwork reconstruction, from outside.

2.1.3 Rear-ventilated facade with substructure Structure:


- Existing plaster coating - Existing brickwork 24 cm 1) - Existing plaster coating - GUTEX Thermofibre/GUTEX Thermoflex between timber frames - GUTEX Multitherm - Counter battens - Wood formwork, closed

2.1.4 Plaster facade Structure:


- Existing plaster coating - Existing brickwork 24 cm 1) - Existing plaster coating - GUTEX Thermowall - GUTEX plaster system

GUTEX Multitherm (mm) 20

GUTEX Thermofibre/ Thermoflex (mm) 140 160 180 140 160 180 140 160 180 140 160 180 140 160 180 140 160 180 140 160 180 140 160 180

U-factor (W/m2K)2) 0.24 0.22 0.20 0.21 0.20 0.18 0.19 0.18 0.17 0.18 0.16 0.15 0.16 0.15 0.14 0.15 0.14 0.13 0.14 0.13 0.12 0.13 0.12 0.12

Phase shift (h) 15.2 15.9 16.6 16.5 17.2 17.9 17.9 18.6 19.3 19.3 20.0 20.7 20.6 21.3 22.0 21.8 22.5 23.3 23.1 23.8 24.5 24.4 25.1 25.8

GUTEX Thermowall (mm) 60 80 100 120 140 160

U-factor (W/m2K) 0.48 0.38 0.32 0.28 0.24 0.21

Phase shift (h) 13.5 14.6 15.9 17.3 18.6 20.0

40

60

80

100

120

140

160

1) Assumed

value = 0.70 W/mK

2) Calculation with 10% wood content

GUTEX Construction Recommendations P. 19

Wall

2. Exterior wall

2.1 Brickwork reconstruction, from outside.

2.1.5 Plaster facade, two-layer Structure:


- Existing plaster coating - Existing brickwork 24 cm 1) - Existing plaster coating - GUTEX Thermosafe-homogen - GUTEX Thermowall - GUTEX plaster system

2.1.6 Plaster facade with substructure Structure:


- Existing plaster coating - Existing brickwork 24 cm 1) - Existing plaster coating - GUTEX Thermofibre/GUTEX Thermoflex between timber frames - GUTEX Thermowall/-gf - GUTEX plaster system

GUTEX Thermowall (mm) 60

GUTEX Thermosafehomogen (mm) 120 140 160 160

U-factor (W/m2K) 0.19 0.17 0.16 0.14 0.13 0.12 0.12

Phase shift (h) 20.1 21.2 22.4 23.8 24.9 26.1 27.5

GUTEX Thermowall (mm)

GUTEX Thermofibre/ Thermoflex (mm) 140 160 180 140

U-factor (W/m2K)2) 0.22 0.20 0.18 0.20 0.18 0.17 0.17 0.16 0.15 0.16 0.15 0.14 0.15 0.14 0.13

Phase shift (h) 16.8 17.5 18.2 18.4 19.1 19.8 19.7 20.4 21.1 21.1 21.8 22.5 22.4 23.1 23.8

40

80 100

180 200 200

60

160 180 140

80

160 180 140

100

160 180 140

120

160 180

1) Assumed value = 0.70 W/mK 2) Calculation with 10% wood content

P. 20 GUTEX Construction Recommendations

2. Exterior wall

2.2 Brickwork reconstruction, from inside.

2.2.1 Brickwork with interior panelling Structure:


- Existing plaster coating - Existing brickwork1) - Existing plaster coating - GUTEX Thermosafe-wd - Vapour barrier/air seal - Battens - Plaster building board/wood formwork

2.2.2 Brickwork, plastered inside Structure:


- Existing plaster coating - Existing brickwork1) - Existing plaster coating - GUTEX Thermoroom - Plaster coating

GUTEX Thermosafe-wd (mm) 40 60 80 100 120 140 160

U-factor (W/m2K) 0.62 0.47 0.38 0.32 0.27 0.24 0.21

Phase shift (h) 12.7 14.2 15.5 16.7 17.9 19.2 20.5

GUTEX Thermoroom (mm) 40 60 80 100

U-factor (W/m2K) 0.62 0.47 0.38 0.31

Phase shift (h) 13.5 14.8 16.0 17.1

1) Assumed

value = 0.70 W/mK

GUTEX Construction Recommendations P. 21

Wall

2. Exterior wall

2.3 Stud wall reconstruction, from outside.

2.3.1 Plaster facade Structure:


- Existing plaster coating - Existing half timber1) - Existing plaster coating - GUTEX Thermowall - GUTEX plaster system

2.3.2 Rear-ventilated facade Structure:


- Existing plaster coating - Existing half timber1) - Existing plaster coating - GUTEX Thermosafe-homogen - GUTEX Multitherm - Counter battens - Wood formwork

GUTEX Thermowall (mm) 100 120 140 160

U-factor (W/m2K) 0.33 0.28 0.25 0.22

Phase shift (h) 12.4 13.7 15.1 16.4

GUTEX Thermosafehomogen (mm) 100 120 140 160 180 200 220 240 240 240

GUTEX Multitherm (mm) 20 20 20 20 20 20 20 20 40 60

U-factor (W/m2K) 0.27 0.24 0.21 0.19 0.17 0.16 0.14 0.13 0.13 0.12

Phase shift (h) 12.5 13.6 14.8 16.0 17.1 18.3 19.4 20.6 21.8 23.1

1) Assumed

value = 0.81 W/mK

P. 22 GUTEX Construction Recommendations

2. Exterior wall

2.3 Stud wall reconstruction, from inside

2.3.3 Half timber, plastered inside Structure:


- Existing half timber 11cm 1) - Lime and cement plaster - GUTEX Thermoroom - Plaster coating

2.3.4 Half timber with interior panelling Structure:


- Existing half timber 11cm 1) - Lime and cement plaster - GUTEX Thermosafe-wd - Vapour barrier/air seal - Battens - PB/PF/wood formwork

GUTEX Thermoroom (mm) 40 60 80 100

U-factor (W/m2K) 0.67 0.5 0.39 0.33

Phase shift (h) 9.2 10.6 11.9 13.1

GUTEX Thermosafe-wd (mm) 40 60 80 100 120 140 160

U-factor (W/m2K) 0.66 0.49 0.39 0.33 0.28 0.24 0.22

Phase shift (h) 9.3 10.8 12.1 13.3 14.6 15.8 17.1

1) Assumed

value = 0.81 W/mK

GUTEX Construction Recommendations P. 23

Wall

2. Exterior wall

2.4 Brickwork new build, insulation, from outside

2.4.1 Rear-ventilated facade Structure:


- Plaster coating - Brick, highly-insulating, 36 cm1) - GUTEX Multitherm - Water-carrying, UV-resistant, permeable membrane - Counter battens - Joint formwork

2.4.2 Rear-ventilated facade Structure:


- Plaster coating - Brick, highly-insulating, 36 cm2) - GUTEX Multitherm - Water-carrying, UV-resistant, permeable membrane - Counter battens - Joint formwork

GUTEX Multitherm (mm) 60 80 100 120 140 160

U-factor (W/m2K) 0.17 0.16 0.15 0.14 0.13 0.12

Phase shift (h) 27.7 28.8 29.9 31.2 32.4 33.7

GUTEX Multitherm (mm) 60 80 100 120 140 160

U-factor (W/m2K) 0.24 0.21 0.19 0.18 0.16 0.15

Phase shift (h) 22.7 23.7 24.9 26.1 27.4 28.7

1) Assumed 2) Assumed

value = 0.09 W/mK value = 0.15 W/mK

P. 24 GUTEX Construction Recommendations

2. Exterior wall

2.4 Brickwork new build, insulation, from outside

2.4.3 Rear-ventilated facade Structure:


- Plaster coating - Brick, highly-insulating, 36 cm1) - GUTEX Thermosafe-homogen 240 mm - GUTEX Multitherm - Counter battens - Wood formwork, closed

2.4.4 Rear-ventilated facade with substructure Structure:


- Plaster coating - Brick, highly-insulating, 36 cm1) - GUTEX Thermofibre/GUTEX Thermoflex between timber frames - GUTEX Multitherm - Counter battens - Wood formwork, closed

GUTEX GUTEX Multitherm Thermosafe-homogen (mm) (mm) 100 120 140 160 180 200 220 240 240 240 20 20 20 20 20 20 20 20 40 60

U-factor (W/m2K) 0.13 0.13 0.12 0.11 0.10 0.10 0.09 0.09 0.09 0.08

Phase shift (h) 30.5 31.7 32.8 34 35.2 36.3 37.5 38.6 39.9 41.2

GUTEX Multitherm (mm) 20

GUTEX Thermofibre/ Thermoflex (mm) 140 160 180 140 160 180 140 160 180 140 160 180 140 160 180 140 160 180 140 160 180 140 160 180

U-factor (W/m2K)2) 0.13 0.12 0.11 0.12 0.11 0.11 0.11 0.11 0.10 0.11 0.10 0.10 0.10 0.10 0.09 0.10 0.09 0.09 0.09 0.09 0.08 0.09 0.08 0.08

Phase shift (h) 29.8 30.5 31.2 31.0 31.8 32.5 32.5 33.2 33.9 33.8 34.5 35.3 35.1 35.9 36.6 36.4 37.1 37.8 37.7 38.4 39.1 38.9 39.6 40.4

40

60

80

100

120

140

160

1) Assumed value = 0.09 W/mK 2) Calculation with 10% wood content

GUTEX Construction Recommendations P. 25

Wall

2. Exterior wall

2.4 Brickwork new build, insulation, from outside

2.4.5 Plaster facade, single-layer Structure:


- Plaster coating - Brick, highly-insulating, 36 cm 1) - GUTEX Thermowall - GUTEX plaster system

2.4.6 Plaster facade, single-layer Structure:


- Plaster coating - Brick, 36 cm2) - GUTEX Thermowall - GUTEX plaster system

GUTEX Thermowall (mm) 60 80 100 120 140 160

U-factor (W/m2K) 0.17 0.15 0.15 0.14 0.13 0.12

Phase shift (h) 27.9 29.1 30.4 31.7 33.1 34.4

GUTEX Thermowall (mm) 60 80 100 120 140 160

U-factor (W/m2K) 0.24 0.21 0.19 0.18 0.16 0.15

Phase shift (h) 22.9 24.1 25.4 26.7 28.1 29.4

1) Assumed 2) Assumed

value = 0.09 W/mK value = 0.15 W/mK

P. 26 GUTEX Construction Recommendations

2. Exterior wall

2.4 Brickwork new build, insulation, from outside

2.4.7 Plaster facade, double-layer Structure:


- Plaster coating - Brick, highly-insulating, 36 cm 2) - GUTEX Thermosafe-homogen - GUTEX Thermowall - GUTEX plaster system

2.4.8 Plaster facade with substructure Structure:


- Plaster coating - Brick, highly-insulating, 36 cm2) - GUTEX Thermofibre/GUTEX Thermoflex between timber frames - GUTEX Thermowall/-gf - GUTEX plaster system

GUTEX Thermowall (mm) 60

GUTEX Thermosafehomogen (mm) 120 140 160 100

U-factor (W/m2K) 0.11 0.10 0.10 0.11 0.11 0.10

Phase shift (h) 34.6 35.8 36.9 34.8 36.0 37.1

GUTEX GUTEX Thermofibre/ U-factor Thermowall/-gf GUTEX (W/m2K) 1) (mm) Thermoflex (mm) 140 40 160 180 140 60 160 180 140 80 160 180 140 100 160 180 140 120 160 180 120 140 140 160 120 160 140 160 0.12 0.11 0.11 0.11 0.11 0.10 0.11 0.10 0.10 0.10 0.10 0.09 0.10 0.10 0.09 0.10 0.09 0.09 0.09 0.09 0.08

Phase shift (h) 31.4 32.1 32.8 33.0 33.7 34.4 34.3 35.0 35.7 35.7 36.4 37.1 37.0 37.7 38.4 37.7 38.4 39.1 39.0 39.7 40.4

80

120 140

1) Calculation with 10 % wood content 2) Assumed value = 0.09 W/mK

GUTEX Construction Recommendations P. 27

Wall

2. Exterior wall

2.5 Timber frame construction

2.5.1 Rear-ventilated facade Structure:


- Plaster building board 12.5 mm - Air seal/panelling 15 mm - GUTEX Thermofibre/ GUTEX Thermoflex between timber uprights - GUTEX Multitherm - Counter battens - Wood formwork

2.5.2 Rear-ventilated facade with installation level Structure:


- Plaster building board 12.5 mm - GUTEX Thermoinstal 50 mm - Air seal/panelling 15 mm - GUTEX Thermofibre/ GUTEX Thermoflex between timber uprights - GUTEX Multitherm - Counter battens - Battens - Wood formwork vertical

GUTEX Multitherm (mm)

20

40

60

80

100

120

140

160

GUTEX Thermofibre/ U-factor1) Thermoflex (W/m2K) (mm) 160 0.23 180 0.21 200 0.19 220 0.18 240 0.17 160 0.21 180 0.19 200 0.17 220 0.16 240 0.15 160 0.18 180 0.17 200 0.16 220 0.15 240 0.14 160 0.17 180 0.16 200 0.15 220 0.14 240 0.13 160 0.15 180 0.14 200 0.14 220 0.13 240 0.12 160 0.14 180 0.13 200 0.13 220 0.12 240 0.11 160 0.13 180 0.13 200 0.12 220 0.11 240 0.11 160 0.12 180 0.12 200 0.11 220 0.11 240 0.10

Phase shift (h) 9.5 10.2 11.0 11.7 12.4 10.8 11.5 12.3 13.0 13.7 12.2 12.9 13.7 14.4 15.1 13.6 14.3 15.0 15.8 16.5 14.9 15.6 16.3 17.1 17.8 16.2 16.9 17.6 18.3 19.1 17.4 18.2 18.9 19.6 20.3 18.7 19.4 20.1 20.9 21.6

Noise 2) insulation value RW . R (dB)

GUTEX Multitherm (mm)

20

40

60

80 > 45 100

120

140

160

GUTEX Thermofibre/ Thermoflex (mm) 160 180 200 220 240 160 180 200 220 240 160 180 200 220 240 160 180 200 220 240 160 180 200 220 240 160 180 200 220 240 160 180 200 220 240 160 180 200 220 240

U-factor1) (W/m2K) 0.18 0.16 0.15 0.14 0.14 0.16 0.15 0.14 0.13 0.13 0.15 0.14 0.13 0.12 0.12 0.14 0.13 0.12 0.12 0.11 0.13 0.12 0.12 0.11 0.11 0.12 0.11 0.11 0.10 0.10 0.11 0.11 0.10 0.10 0.09 0.11 0.10 0.10 0.09 0.09

Phase shift (h) 13.0 13.7 14.4 15.2 15.9 14.3 15.0 15.8 16.5 17.2 15.7 16.4 17.2 17.9 18.6 17.1 17.8 18.5 19.3 20.0 18.4 19.1 19.8 20.6 21.3 19.7 20.4 21.1 21.8 22.6 20.9 21.7 22.4 23.1 23.8 22.2 22.9 23.6 24.4 25.1

Noise 2) insulation value RW . R (dB)

> 45

1) Calculation with 10 % wood content 2) Values in accordance with "Informationsdienst Holz", series 3, part 3, sequence 4, RW , R = calculated value incl. allowance

P. 28 GUTEX Construction Recommendations

2. Exterior wall

2.5 Timber frame construction

2.5.3 Plaster facade Structure:


- Plaster building board 12.5 mm - OSB board (air seal) 15 mm - GUTEX Thermofibre/ GUTEX Thermoflex between timber uprights - GUTEX Thermowall/-gf - GUTEX plaster system

2.5.4 Plaster facade with Installation level Structure:


- Plaster building board 12.5 mm Wall - GUTEX Thermoinstal 50 mm - OSB board (air seal) 15 mm - GUTEX Thermofibre/ GUTEX Thermoflex between timber uprights - GUTEX Thermowall/-gf - GUTEX plaster system

GUTEX Thick- Thermofibre/ Uness factor1) Thermoflex (mm) (W/m2K) (mm) 140 160 180 200 220 240 140 160 180 200 220 240 140 160 180 200 220 240 140 160 180 200 220 240 140 160 180 200 220 240 140 160 180 200 220 240 140 160 180 200 220 240 0.23 0.21 0.19 0.18 0.16 0.15 0.21 0.19 0.18 0.16 0,15 0.14 0.18 0.17 0.16 0.15 0.14 0.13 0.17 0.15 0.14 0.14 0.13 0.12 0.15 0.14 0.13 0.13 0.12 0.11 0.14 0.13 0.13 0.12 0.11 0.11 0.13 0.12 0.12 0.11 0.11 0.10

Phase shift (h) 10.4 11.1 11.8 12.6 13.3 14.0 12.0 12.7 13.4 14.2 14.9 15.6 13.3 14.0 14.7 15.5 16.2 16.9 14.7 15.4 16.1 16.9 17.6 18.3 16.1 16.8 17.5 18.2 18.8 19.7 17.4 18.1 18.8 19.5 20.3 21.0 18.8 19.5 20.2 20.9 21.6 22.3

Noise insulation value RW , R (dB) 2)

GUTEX Thick- Thermofibre/ U-factor1) ness Thermoflex (W/m2K) (mm) (mm) 140 160 180 200 220 240 140 160 180 200 220 240 140 160 180 200 220 240 140 160 180 200 220 240 140 160 180 200 220 240 140 160 180 200 220 240 140 160 180 200 220 240 0.18 0.16 0.15 0.14 0.13 0.13 0.16 0.15 0.14 0.13 0.13 0.12 0.15 0.14 0.13 0.12 0.12 0.11 0.14 0.13 0.12 0.12 0.11 0.10 0.13 0.12 0.11 0.11 0.10 0.10 0.12 0.11 0.11 0.10 0.10 0.09 0.11 0.11 0.10 0.10 0.09 0.09

40 GUTEX Thermowall-gf 60

40 GUTEX Thermowall-gf 60

40

80

80

100

100

GUTEX Thermowall

120

44

GUTEX Thermowall

120

140

140

160

160

Noise Phase insulation value shift RW . R (h) (dB) 2) 13.9 14.6 15.3 16.0 16.8 17.5 42 15.5 16.2 16.9 17.7 18.4 19.1 16.8 17.5 18.2 19.0 19.7 20.4 18.2 18.9 19.6 20.3 21.1 21.8 19.6 20.3 21.0 47 21.7 22.4 23.1 20.9 21.6 22.3 23.0 23.8 24.5 22.2 23.0 23.7 24.4 25.1 25.8

1) Calculation with 10 % wood content 2) Executed in accordance with inspection certificate P-SAC-02/III-321

GUTEX Construction Recommendations P. 29

2. Exterior wall

2.6 Prefabricated house reconstruction

2.6.1 Plaster facade Structure:


- Existing plasterboard 12.5 mm - Existing chipboard 19 mm - Existing PE membrane - GUTEX Thermofibre/GUTEX Thermoflex between timber uprights - GUTEX Thermowall/-gf - GUTEX plaster system

2.6.2 Rear-ventilated facade Structure:


- Existing plasterboard 12.5 mm - Existing chipboard 19 mm - Existing PE membrane - GUTEX Thermofibre/GUTEX Thermoflex between timber uprights - GUTEX Multitherm - Counter battens - Facade

GUTEX Thermofibre/ GUTEX Thermoflex Thermowall/-gf between timber (mm) uprights (mm) 40 60 80 140 100 120 140 160 40 60 80 160 100 120 140 160

U-factor (W/mK) 1) 0.23 0.21 0.18 0.16 0.15 0.14 0.13 0.21 0.19 0.17 0.15 0.14 0.13 0.12

Phase shift (h)

GUTEX Thermofibre/ Thermoflex between timber uprights (mm)

GUTEX Multitherm (mm) 40 60 80

U-factor (W/mK) 1) 0.22 0.20 0.18 0.17 0.15 0.14 0.13 0.20 0.18 0.17 0.15 0.14 0.13 0.12

Phase shift (h)

10.6 12.2 13.6 14.9 16.3 17.6 19.0 11.3 13.0 14.3 15.6 17.0 18.3 19.7 160 140

10.3 11.7 13.1 14.4 15.7 17.0 18.2 11.0 12.5 13.8 15.1 16.4 17.7 18.9

100 120 140 160 40 60 80 100 120 140 160

1) Calculation with 10 % wood content

P. 30 GUTEX Construction Recommendations

2. Exterior wall

2.6 Prefabricated house reconstruction

2.6.3 Rear-ventilated wall facing Structure:


- Existing plasterboard 12.5 mm - Existing chipboard 19 mm - Existing PE membrane - GUTEX Thermofibre/ GUTEX Thermoflex between timber uprights - GUTEX Multitherm - Wall formwork sheeting pro clima SOLITEX FRONTA QUATTRO - Rear-ventilated clinker brick facade

GUTEX Thermofibre/ Thermoflex between timber uprights (mm)

GUTEX Multitherm (mm) 40 60 80

U-factor (W/mK) 1) 0.22 0.20 0.18 0.17 0.15 0.14 0.13 0.20 0.18 0.17 0.15 0.14 0.13 0.12

Phase shift (h)

10.3 11.7 13.1 14.4 15.7 17.0 18.2 11.0 12.5 13.8 15.1 16.4 17.7 18.9

140

100 120 140 160 40 60 80

160

100 120 140 160

1) Calculation with 10% wood content

GUTEX Construction Recommendations P. 31

Wall

2. Exterior wall
2.7 Solid wood element

2.7.1 Rear-ventilated facade with installation level Structure:


- Plaster building board 12.5 mm - GUTEX Thermoinstal 50 mm - Vapour barrier/air seal - Solid wood wall element 100 mm - GUTEX Multitherm - Water-carrying, UV-resistant, permeable membrane - Counter battens - Joint formwork

2.7.2 Rear-ventilated facade Structure:


- Plaster building board 12.5 mm - Vapour barrier/air seal - Solid wood wall element 100 mm - GUTEX Thermosafe-homogen - GUTEX Multitherm 20 mm - Counter battens - Wood formwork

GUTEX Multitherm (mm) 100 120 140 160

U-factor Phase shift (h) Noise insulation (W/mK) value RW . R(dB) 1) 0.21 0.19 0.17 0.16 18.5 19.8 21.0 22.3 < 50

GUTEX Thermosafehomogen (mm) 100 120 140 160 180 200 220 240

U-factor (W/mK) 0.24 0.21 0.19 0.17 0.16 0.14 0.13 0.13

Phase shift (h) Noise insulation value RW . R(dB) 1) 15.0 16.2 17.3 18.5 19.7 20.8 22.0 23.1 < 45

1) Values in accordance with "Informationsdienst Holz", series 3, part 3, sequence 4, RW , R = calculated value incl. allowance

P. 32 GUTEX Construction Recommendations

2. Exterior wall
2.7 Solid wood element

2.7.3 Rear-ventilated facade with installation level Structure:


- Plaster building board - GUTEX Thermoinstal 50 mm - Vapour barrier/air seal - Solid wood wall element 100 mm - GUTEX Thermosafe-homogen - GUTEX Multitherm 20 mm - Counter battens - Wood formwork

2.7.4 Rear-ventilated facade with substructure Structure:


- Solid wood wall element 100 mm - GUTEX Thermofibre/GUTEX Thermoflex between double I-joists - GUTEX Multitherm - Water-carrying, UV-resistant, permeable membrane - Counter battens - Joint formwork

GUTEX Thermosafe-homogen (mm) 100 120 140 160 180 200 220 240

U-factor Phase shift (h) (W/mK) 0.18 0.17 0.15 0.14 0.13 0.12 0.11 0.11 19.1 20.2 21.4 22.6 23.7 24.9 26.0 27.2

Noise insulation value RW . R(dB) 2)

GUTEX Multitherm (mm)

GUTEX Thermofibre/Thermoflex (mm) 200 220 240 300 360 400 200 220 240 300 360 400 200 220 240 300 360 400

U-factor (W/mK) 1) 0.16 0.15 0.15 0.13 0.11 0.11 0.15 0.14 0.14 0.12 0.11 0.10 0.14 0.13 0.13 0.11 0.10 0.10

Phase shift (h) 16.3 17.1 17.8 20.0 22.2 23.6 17.6 18.4 19.1 21.3 23.5 24.9 19.0 19.8 20.5 22.7 24.9 26.3

20 < 47

40

60

1) Calculation with 10 % wood content 2) Values in accordance with "Informationsdienst Holz", series 3, part 3, sequence 4, RW , R = calculated value incl. allowance

GUTEX Construction Recommendations P. 33

Wall

2. Exterior wall
2.7 Solid wood element

2.7.5 Plaster facade, single-layer Structure:


- Plaster building board 12.5 mm - Vapour barrier/air seal - Solid wood wall element 100 mm - GUTEX Thermowall - GUTEX plaster system

2.7.6 Plaster facade, single-layer, with installation level Structure:


- Plaster building board 12.5 mm - GUTEX Thermoinstal 50 mm - Vapour barrier/air seal - Solid wood wall element 100 mm - GUTEX Thermowall - GUTEX plaster system

GUTEX Thermowall (mm) 100 120 140 160

U-factor (W/mK) 0.28 0.25 0.22 0.20

Phase shift (h) 14.9 16.3 17.7 19.0

Noise insulation value RW . R(dB) 1)

GUTEX Thermowall U-factor (W/mK) (mm) 100 120 140 160 0.21 0.19 0.17 0.16

Phase shift (h) 19.0 20.4 21.7 23.1

Noise insulation value RW . R(dB) 1)

38

40

1) Execution in accordance with inspection certificate P-SAC-02/III-321

P. 34 GUTEX Construction Recommendations

2. Exterior wall
2.7 Solid wood element

2.7.7 Plaster facade, double-layer with installation level Structure:


- Plaster building board 12.5 mm - GUTEX Thermoinstal 50 mm - Vapour barrier/air seal - Solid wood wall element 100 mm - GUTEX Thermosafe-homogen - GUTEX Thermowall - GUTEX plaster system GUTEX Thermowall (mm) GUTEX Thermosafehomogen (mm) 120 140 160 60 180 200 220 240 120 140 80 160 180 200 220 120 140 100 160 180 200 Noise insuU-factor Phase shift lation value (W/mK) (h) RW . R(dB) 2) 0.14 0.13 0.12 0.12 0.11 0.10 0.10 0.13 0.12 0.12 0.11 0.10 0.10 0.12 0.12 0.11 0.10 0.10 23.2 24.3 25.5 26.6 27.8 28.9 30.1 24.6 25.7 26.9 28.0 29.2 30.3 25.9 27.1 28.2 29.4 30.5 40

2.7.8 Plaster facade with substructure Structure:


- Plaster building board 12.5 mm - GUTEX Thermoinstal 50 mm - Vapour barrier/air seal - Solid wood wall element 100 mm - GUTEX Thermofibre/GUTEX Thermoflex between double I-joists - GUTEX Thermowall/-gf - GUTEX plaster system GUTEX Thermofibre/ Thermoflex (mm) 200 220 40 240 300 360 400 200 220 60 240 300 360 400 200 220 80 240 300 360 400

GUTEX Thermowall/-gf (mm)

U-factor (W/mK)1) 0.13 0.12 0.12 0.10 0.09 0.09 0.12 0.11 0.11 0.10 0.09 0.09 0.11 0.11 0.10 0.09 0.08 0.08

Phase shift (h) 22.0 22.7 23.5 25.7 27.8 29.3 23.6 24.3 25.1 27.2 29.4 30.9 24.9 25.6 26.4 28.5 30.7 32.2

1) Calculation with 10 % wood content 2) Execution in accordance with inspection certificate P-SAC-02/III-321

GUTEX Construction Recommendations P. 35

Wall

3. Lightweight partition walls


3.1 Timber upright construction

3.1.1 Single-panelled on both sides Structure:


- Single panelling - GUTEX Thermosafe/Thermoflex*/Thermofibre2) between timber uprights - Single panelling Deep timGUTEX Noise insulaU-factor 1) ber uprights Thermosafe tion value RW 2 (W/m K) (mm) (mm) (dB) 60 40 0.64 37 140 140 0.28 40 140 120 0.30 40 60 60 140 40 60 140 0.70 0.60 0.29 42 47 48

3.1.2 Double-panelled on one side; single-panelled on one side Structure:


- Double panelling - GUTEX Thermosafe/Thermoflex*/Thermofibre2) between timber uprights - Single panelling Deep timber uprights (mm) 60 GUTEX Thermosafe (mm) 40 Noise insuU-factor 1) lation value 2 (W/m K) RW (dB) 0.68 45

Panelling (mm) OSB board 15 OSB board 15 Plasterboard 12.5 Plasterboard 12.5 Fibre reinforced plasterboard 12.5 Fibre reinforced plasterboard 12.5

Panelling (mm) Plasterboard 9.5 Plasterboard 12.5 Plasterboard 12.5 Fibre reinforced plasterboard 10 Fibre reinforced plasterboard 12.5 Fibre reinforced plasterboard 12.5

60 140

60 140

0.59 0.29

50 50

Panelling (mm) Plasterboard 9.5 Plasterboard 12.5

Deep timGUTEX Noise insulaU-factor 1) ber uprights Thermosafe tion value (W/m2K) (mm) (mm) RW (dB) 60 40 0.66 47

* The stated noise values

can be up to 3 dB worse when using GUTEX Thermoflex 1) Calculation with 10 % wood content 2) There are still no noise values for constructions using GUTEX Thermofibre

Plasterboard 12.5 Plasterboard 9.5 Plasterboard 9.5 OSB board 15 OSB board 15 Plasterboard 9.5 Fibre reinforced plasterboard 10 OSB board 15 OSB board 15 Fibre reinforced plasterboard 10 Fibre reinforced plasterboard 10 Fibre reinforced plasterboard 12.5 Fibre reinforced plasterboard 12.5 Fibre reinforced plasterboard 10

60

40

0.61

47

140

120

0.29

51

3.1.3 Double-panelled on both sides Structure:


- Double panelling - GUTEX Thermosafe/Thermoflex*/Thermofibre2) between timber uprights - Double panelling

60

60

0.58

52

140

140

0.29

52

P. 36 GUTEX Construction Recommendations

3. Lightweight partition walls


3.2 Metal upright construction

3.2.1 Single-panelled on both sides Structure:


- Panelling - GUTEX Thermosafe/-homogen between metal uprights - Panelling

3.2.2Double-panelled on both sides Structure:


- Double panelling - GUTEX Thermosafe/-homogen between metal uprights - Double panelling

Panelling (mm) Plasterboard 12.5 Plasterboard 12.5

Deep metal uprights (mm) 75 125

GUTEX Thermosafe (mm) 40 100

U-factor (W/m2K) 1.21 0.90

Noise insulation value RW(dB) 47 49

Panelling (mm) Plasterboard 9.5 Plasterboard 12.5 Plasterboard 12.5 Plasterboard 9.5 Fibre reinforced plasterboard 10 Fibre reinforced plasterboard 12.5 Fibre reinforced plasterboard 12.5 Fibre reinforced plasterboard 10

Deep metal uprights (mm)

GUTEX Thermosafe (mm)

U-factor (W/m2K)

Noise insulation value RW(dB)

125

100

0.79

54

50

40

1.17

55

125

100

0.84

62

GUTEX Construction Recommendations P. 37

Lightweight partition walls

4. Concrete ceiling
New build and reconstruction

4.1 Cement screed Structure:


- Cement screed 50 mm - Moisture proofing membrane - GUTEX insulating layer - Moisture barrier to DIN 18195 - Concrete ceiling 140 mm

4.2 Mastic asphalt Structure:


- Mastic asphalt 30 mm - Corrugated cardboard 2.5 mm - GUTEX insulating layer - Moisture barrier to DIN 18195 - Concrete ceiling 140 mm

Insulating layer (mm) 40 60 80 100 120 140 21/20 31/30 2x21/20 2x31/30 21/20 + 31/30

GUTEX Thermosafe-wd

GUTEX Thermofloor

Installation height (mm) 90 110 130 150 170 190 70 80 90 110 100

Standard U-factor impact (W/m2K) noise level Lnw (dB) 0.68 0.51 0.40 0.33 0.28 0.25 1.05 55 0.83 54 0.68 55 0.51 54 0.58 55

Impact sound attenuation Lw (dB) GUTEX Thermosafe-wd

Insulating layer (mm) 40 60 80 100 120 140 21/20 31/30 2x21/20 2x31/30 21/20+ 31/30

24 24 24 25 24

GUTEX Thermofloor

Installation height (mm) 75 95 115 135 155 175 55 65 75 95 85

Standard U-factor impact (W/m2K) noise level Lnw (dB) 0.69 0.51 0.40 0.33 0.28 0.25 1.06 51* 0.83 54 0.69 0.51 0.58

Impact sound attenuation Lw (dB)

23 28

* In combination with 30 mm of perlite ballast below the GUTEX Thermofloor

P. 38 GUTEX Construction Recommendations

4. Concrete ceiling
New build and reconstruction

4.3 Sill plate/dry screed element Structure:


- Sill plate/dry screed element * - GUTEX insulating layer - Moisture barrier to DIN 18195 - Concrete ceiling 140 mm

4.4 Solid wooden foor Structure:


- Solid wooden floor min. 19 mm - GUTEX Thermosafe-nf 41/40 mm - GUTEX insulating layer - Moisture barrier to DIN 18195 - Concrete ceiling 140 mm

Insulating layer (mm) 20 30 40 60 80 100 120** 140** 21/20 31/30**

GUTEX Thermosafe-wd

GUTEX Thermofloor

Installation height (mm) 45 55 65 85 105 125 145 165 45 55

Standard Impact U-factor impact sound at(W/m2K) noise level tenuation Lnw (dB) Lw (dB) 0.92 0.75 48* 0.63 0.47 0.38 0.32 0.27 0.24 0.92 0.75

Insulating layer (mm) GUTEX Standard-n 8 20 30 40 60 80 100

Installation height (mm) 68 80 90 100 120 140 160

U-factor (W/ m2K) 0.55 0.47 0.42 0.38 0.32 0.27 0.24

Standard Impact noise impact attentuation noise level Lw (dB) Lnw (dB) 52 26

GUTEX Thermosafe-wd

* Sill plates: OSB min. 22 mm; particleboard min. 25 mm; dry screed element min. 25 mm ** only in combination with sill plates in accordance with technical datasheet

GUTEX Construction Recommendations P. 39

Concrete ceiling

5. Beamed ceiling
New build and reconstruction

Bare ceiling 1 Structure:


- Wooden floor/exposed formwork, bolted - Beam position 220/60 mm, - Grid 62.5 cm

Raw ceiling 2 Structure:


- Wooden floor/exposed formwork, bolted - Beam position 220/60 mm, grid 62.5 cm - Cavity insulation 100 mm* - Bay insert: sprung rod fastened to battens - PBP 12.5 mm, bolted (clearance between bottom edge of battens to top edge of panelling 100 mm, grid FS 41.5 cm)

Standard impact noise level Lnw (dB) 91

Assessed noise insulation Rw 24

Standard impact noise level Lnw (dB) 71

Assessed noise insulation Rw 42

Raw ceiling 3 Structure:


- FPY 25 mm bolted - Beam position 220/60 mm, grid 62.5 cm - Cavity insulation 100 mm* - Battens, grid 41.5 cm bolted - PBP 12.5 mm, bolted

Standard impact noise level Lnw (dB) 75 *


e.g. GUTEX Thermoflex

Assessed noise insulation Rw 45

P. 40 GUTEX Construction Recommendations

5. Beamed ceiling
New build and reconstruction

5.1.1 Cement screed, open beam position Structure:


- Cement screed 50 mm - Moisture proofing membrane - GUTEX insulating layer - Drip strip - Exposed formwork - Raw ceiling 1 (see page 40)

5.1.2 Cement screed, semi-open beam position Structure:


- Cement screed 50 mm - Moisture proofing membrane - GUTEX insulating layer - Drip strip - Exposed formwork - Raw ceiling 2 (see page 40)

Insulating layer (mm) 40 60 80 100 120 140 21/20 31/30 2x21/20 2x31/30 21/20+ 31/30

GUTEX Thermosafe-wd

GUTEX Thermofloor

Installation height (mm) 90 110 130 150 170 190 70 80 90 110 100

Standard Impact noise U-factor impact attenuation (W/m2K) noise level Lw,H (dB) Lnw (dB) 0.64 0.48 0.38 0.32 0.28 0.24 0.94 0.76 79 10 0.64 0.48 0.55 75 10

Insulating layer (mm) 40 60 80 100 120 140 21/20 31/30 2x21/20 2x31/30 21/20+ 31/30

Installation height (mm) 90 110 130 150 170 190 70 80 90 110 100

Standard Impact U-factor impact noise at(W/m2K) noise level tenuation Lnw (dB) Lw,H (dB) 0.25 0.22 0.20 0.18 0.17 0.15 0.29 0.27 0.25 0.22 0.24

GUTEX Thermosafe-wd

50* 48*

11* 15*

GUTEX Thermofloor

* In combination with 50 mm of limescale ballast below GUTEX Thermofloor

GUTEX Construction Recommendations P. 41

Beamed ceiling

5. Beamed ceiling
New build and reconstruction

5.1.3 Cement screed, closed beam position Structure:


- Cement screed 50 mm - Moisture proofing membrane - GUTEX insulating layer - Drip strip - Raw ceiling 3 (see page 40)

5.2.1 Mastic asphalt, open beam position Structure:


- Mastic asphalt 35 mm - Titacord corrugated cardboard 2.5 mm - GUTEX insulating layer - Drip strip - Raw ceiling 1 (see page 40)

Insulating layer (mm) 40 60 GUTEX 80 Thermosafe-wd 100 120 140 21/20 31/30 GUTEX 2x21/20 Thermofloor 2x31/30 21/20+ 31/30

Installation height (mm) 90 110 130 150 170 190 70 80 90 110 100

Standard Impact noise U-factor impact attenuation 2 (W/m K) noise level Lw,H (dB) Lnw (dB) 0.24 0.21 0.19 0.18 0.16 0.15 0.27 0.26 0.24 0.21 0.23

Insulating layer (mm) 40 60 GUTEX 80 Thermosafe-wd 100 120 140 21/20 31/30 GUTEX 2x21/20 Thermofloor 2x31/30 21/20+ 31/30

Installation height (mm) 78 98 108 128 148 168 58 68 78 98 88

U-factor (W/m2K) 0.63 0.48 0.38 0.32 0.28 0.24 0.94 0.76 0.63 0.48 0.55

Standard impact noise level Lnw (dB)

Impact noise attenuation Lw,H (dB)

62*

11*

60 (48*)

15

76 1) 76 1) 74 1) 74 1) 74 1)

15 1) 15 1) 17 1) 17 1) 17 1)

* Bottom layer: 2x PBP 12.5 mm on sprung rod

1) Calculated in accordance with wood information service, series 3 edition, part 3, sequence 3

P. 42 GUTEX Construction Recommendations

5. Beamed ceiling
New build and reconstruction

5.2.2 Mastic asphalt, semi-open beam position Structure:


- Mastic asphalt 35 mm - Titacord corrugated cardboard 2.5 mm - GUTEX insulating layer - Drip strip - Raw ceiling 2 (see page 40

5.2.3 Mastic asphalt, closed beam position Structure:


- Mastic asphalt 35 mm - Titacord corrugated cardboard 2.5 mm - GUTEX insulating layer - Drip strip - Raw ceiling 3 (see page 40)

Insulating layer (mm) 40 60 80 100 120 140 21/20 31/30 2x21/20 2x31/30 21/20+ 31/30

Installation height (mm) 78 98 108 128 148 168 58 68 78 98 88

Standard U-factor impact (W/m2K) noise level Lnw (dB) 0,25 0,22 0,21 0,18 0,17 0,15 0,29 0,27 0,25 0,22 0,24

Impact noise attenuation Lw,H (dB)

Insulating layer (mm) 40 60 GUTEX 80 Thermosafe-wd 100 120 140 21/20 31/30 2x21/20 GUTEX Thermofloor 2x31/30 21/20+ 31/30

Installation height (mm) 78 98 108 128 148 168 58 68 78 98 88

U-factor (W/m2K) 0.24 0.21 0.19 0.18 0.16 0.15 0.27 0.26 0.24 0.21 0.23

Standard impact noise level Lnw (dB)

Impact noise attenuation Lw,H (dB)

Thermosafe-wd

Thermofloor

54 1)

17 1)

57 1)

17 1)

* Only in combination with 50 mm of limescale ballast below the GUTEX Thermofloor


1) Calculated in accordance with wood information serivce, series 3 edition, part 3, sequence 3

* Only in combination with 50 mm of limescale ballast below GUTEX Thermofloor ** only if PBP is mounted to sprung rod
1) Calculated in accordance with wood information service, series 3 edition, part 3, sequence 3

GUTEX Construction Recommendations P. 43

Beamed ceiling

57 1) 57(48*)1) 54 1) 54 1)

15 1) 15 1) 17 1) 17 1)

57 1) 57 (48*) 57 1) 57 1)

15 1) 14** 17 1) 17 1)

5. Beamed ceiling
New build and reconstruction

5.3.1 Sill plate/dry screed element Structure:


- Sill plate/dry screed element - GUTEX insulating layer - Drip strip - Raw ceiling 1 (see page 40)

5.3.2 Sill plate/dry screed element Structure:


- Sill plate/dry screed element - GUTEX insulating layer - Drip strip - Raw ceiling 2 (see page 40)

Insulating layer (mm) 20 30 40 60 80 100 120 140 21/20 31/30

Installation height (mm) 45 55 65 85 105 125 145 165 45 55

Standard U-factor impact (W/m2K) noise level Lnw (dB) 0.82 0.68 0.58 0.45 0.36 0.31 0.26 0.23 0.82 0.68

Impact noise attenuation Lw,H (dB)

Insulating layer (mm) 20 30 40 60 80 100 120 140 21/20 31/30

Installation height (mm) 45 55 65 85 105 125 145 165 45 55

Standard Impact noise U-factor impact attenuation 2 (W/m K) noise level Lw,H (dB) Lnw (dB) 0.28 0.26 0.25 0.22 0.20 0.18 0.16 0.15 0.28 0.26

GUTEX Thermosafe-wd

GUTEX Thermosafe-wd

GUTEX Thermofloor

6 1)

GUTEX Thermofloor

50** 65 1)

9** 6 1)

** Only in combination with a 25 mm dry screed element from Fermacell and if limescale ballast is 50 mm
1) Calculated in accordance with wood information service, series 3 edition, part 3, sequence 3

P. 44 GUTEX Construction Recommendations

5. Beamed ceiling
New build and reconstruction

5.3.3 Sill plate/dry screed element Structure:


- Sill plate/dry screed element - GUTEX insulating layer - Drip strip - Raw ceiling 3 (see page 40)

5.4.1 Solid wooden floor Structure:


- Wooden floor min. 19 mm - GUTEX Thermosafe-nf 41/40 mm - GUTEX insulating layer - Drip strip - Raw ceiling 1 (see page 40)

Insulating layer (mm) 20 30 40 60 80 100 120 140 21/20 31/30

GUTEX Thermosafe-wd

GUTEX Thermofloor

6 1)

** Only in combination with 60 mm of limescale ballast below the GUTEX Thermosafe-wd

* Only in combination with a 25 mm dry screed element from Fermacell 1) Calculated in accordance with wood information service, series 3 edition, part 3, sequence 3

GUTEX Construction Recommendations P. 45

Beamed ceiling

GUTEX Thermosafe-wd

Installation height (mm) 45 55 65 85 105 125 145 165 45 55

Standard U-factor impact (W/m2K) noise level Lnw (dB) 0.26 0.25 65* 0.23 0.21 0.19 0.17 0.16 0.15 0.26 67* 0.25 69 1)

Impact noise attenuation Lw,H (dB) GUTEX Standard-n

Insulating layer (mm) 8 20 30 40 60 80 100

Installation height (mm) 67 79 89 99 119 139 159

U-factor (W/m2K) 0.54 0.46 0.41 0.37 0.31 0.27 0.24

Standard impact noise level Lnw (dB)

Impact noise attenuation Lw,H (dB) 11

57**

5. Beamed ceiling
New build and reconstruction

5.4.2 Sold wooden floor, semi-open beam position Structure:


- Wooden floor min. 19 mm - GUTEX Thermosafe-nf 41/40 mm - GUTEX insulating layer - Drip strip - Raw ceiling 2 (see page 40)

5.4.3 Solid wooden floor, closed beam position Structure:


- Wooden floor min. 19 mm - GUTEX Thermosafe-nf 41/40 mm - GUTEX insulating layer - Drip strip - Raw ceiling 3 (see page 40)

Insulating layer (mm) GUTEX Standard-n 8 20 30 40 60 80 100

Installation height (mm) 67 79 89 99 119 139 159

U-factor (W/m2K) 0.24 0.22 0.21 0.20 0.18 0.16 0.15

Standard impact noise level Lnw (dB)

Impact noise attenuation Lw,H (dB) GUTEX Standard-n

Insulating layer (mm) 8 20 30 40 60 80 100

Installation height (mm) 67 79 89 99 119 139 159

Standard Impact U-factor impact noise at(W/m2K) noise level tenuation Lnw (dB) Lw,H (dB) 0.23 0.21 0.20 0.19 0.17 0.17 0.15 48* 11*

49* GUTEX Thermosafe-wd

GUTEX Thermosafe-wd

* Only in combination with 60 mm of limescale ballast below the GUTEX Thermosafe-wd

* Bottom layer: 2 x plasterboard 12.5 mm on sprung rod

P. 46 GUTEX Construction Recommendations

6. Top floor ceiling


New build and reconstruction

6.1 Concrete ceiling, non-insulated Structure:


- Sill plate min. 13 mm - GUTEX Thermosafe-homogen - Moisture barrier to DIN 18195 - Concrete ceiling 140 mm

6.2 Beamed ceiling, closed, non-insulated Structure:


- Sill plate min. 13 mm - GUTEX Thermosafe-homogen - Vapour barrier/air seal - Existing board panelling/sill plate - Existing beam position, non-insulated - Existing HWL board, plastered

Insulating layer (mm) GUTEX Thermosafehomogen 160 180 200 220 240

U-factor (W/m2K) 0.21 0.19 0.17 0.16 0.15

Phase shift (h) 13.5 14.6 15.8 17.0 18.1

Insulating layer (mm) 140 160 180 200 220 240

U-factor (W/m2K) 0.21 0.19 0.17 0.15 0.14 0.13

Phase shift (h) 14.2 15.3 16.5 17.6 18.8 19.9

GUTEX Thermosafehomogen

6.3 Beamed ceiling, closed, partially insulated Structure:


Sill plate min. 13 mm - GUTEX Thermosafe-homogen - Vapour barrier/air seal - Existing board panelling/sill plate - Existing beam position - Existing cavity insulation 100 mm - Existing HWL board, plastered 30 mm GUTEX Thermosafehomogen

Insulating layer (mm) 100 120 140 160 180 200 220 240

U-factor (W/m2K) 0.17 0.15 0.14 0.13 0.12 0.11 0.11 0.10

Phase shift (h) 16.2 17.3 18.4 19.6 20.7 21.9 23.0 24.2

Use of the insulated top floor ceiling in combination with Thermosafehomogen is not suitable for residential purposes.

GUTEX Construction Recommendations P. 47

Top floor ceiling

7. Fire and noise insulation


7.1 On-roof insulation Timber beam roof construction with timber beams in fire resistance class F30-B/F-90-B exposed to fire on three sides

Exterior panelling 1 Concrete roofing tiles 30 mm support battens 40/60 mm counter battens 18 mm GUTEX Multiplex-top 120 mm GUTEX Thermosafe-homogen Structure 1 18 mm formwork 100 mm rafters 15 mm timberboard 100 mm rafters 9.5 mm PBP 12 mm timberboard 100 mm rafters 10 mm GF 12 mm timberboard 100 mm rafters 15 mm GF 2 x 12.5 mm GF 15 mm timberboard 100 mm rafters 4 x 10 mm GF 15 mm timberboard 100 mm rafters 2 Concrete roofing tiles 30 mm support battens 40/60 mm counter battens 18 mm GUTEX Multiplex-top 280 mm GUTEX Thermosafe-homogen 3 Concrete roofing tiles 30 mm support battens 40/60 mm counter battens 60 mm GUTEX Ultratherm 120 mm GUTEX Thermosafe-wd
4

Concrete roofing tiles 30 mm support battens 40/60 mm counter battens 60 mm GUTEX Ultratherm 240 mm GUTEX Thermosafe-wd

STS: RW,R = 43 dB DTS: RW,R = 45 dB

STS: RW,R = 44 dB DTS: RW,R = 49 dB

STS: RW,R = 40 dB DTS: RW,R = 43 dB

STS: RW,R = 42 dB DTS: RW,R = 46 dB

2 F 30 Interior panelling

STS: RW,R = 44 dB DTS: RW,R = 46 dB

STS: RW,R = 45 dB DTS: RW,R = 51 dB

STS: RW,R = 42 dB DTS: RW,R = 45 dB

STS: RW,R = 43 dB DTS: RW,R = 48 dB

5 F 90

STS: RW,R = 48 dB DTS: RW,R = 51 dB

STS: RW,R = 49 dB DTS: RW,R = 55 dB

STS: RW,R = 46 dB DTS: RW,R = 49 dB

STS: RW,R = 47 dB DTS: RW,R = 52 dB

Intermediate values may be determined by linear interpolation.


RW,R: assessed noise insulation value, calculated value from test bed measurement RW,R: assessed noise insulation value, calculated value from transfer
STS: Single thread screw DTS: Double thread screw

Further detailed information on applications, fastening systems for the materials to be used, structural analyses, connections and fittings can be found in the general building inspection certificate no. P-SAC 02/III-370 and report no. 1753849-1.

P. 48 GUTEX Construction Recommendations

7. Fire and noise insulation


7.2 Inter-rafter insulation Inter-rafter insulation F30-B, from inside /F-90-B, from outside
RW,R: assessed noise insulation value, calculated value from test bed measurement RW,R: assessed noise insulation value, calculated value from transfer
Roof covering: concrete roofing tiles DRw = 0 dB, clay roofing tiles DRw = -2 dB, Plain tile DRw = +1 dB, steel plate on formwork (without support battens) DRw =- 5dB, slate on formwork (without support battens)DRw = -5 dB Insulation: cavity insulation as per Table 1, RWR-values may be calculated by linear interpolation depending on the insulation thickness

Exterior panelling 1 Concrete roofing tiles 30 mm support battens 40/60 mm counter battens 50 mm Ultratherm Structure 1 140 mm rafters + insulation 24 mm rafters 12.5 mm PBP or PF 140 mm rafters + insulation 15 mm timberboard 12.5 mm PBP or PF 140 mm rafters + insulation 24 mm rafters 18 mm formwork 140 mm rafters + insulation 40 mm Thermosafe-wd 24 mm rafters 18 mm formwork 140 mm rafters + insulation 40 mm Thermosafe-wd 24 mm rafters 12.5 mm PBP or PF 140 mm rafters + insulation 24 mm rafters 60 mm Thermowall-gf 5 mm plaster 140 mm insulation: RW,R = 43 dB 200 mm insulation: RW,R = 44 dB 300 mm insulation: RW,R = 45 dB 140 mm insulation: RW,R = 45 dB 200 mm insulation: RW,R = 46 dB 300 mm insulation: RW,R = 47 dB 140 mm insulation: RW,R = 48 dB 200 mm insulation: RW,R = 50 dB 300 mm insulation: RW,R = 50 dB 140 mm insulation: RW,R = 46 dB 200 mm insulation: RW,R = 49 dB 300 mm insulation: RW,R = 49 dB 140 mm insulation: RW,R = 46 dB 200 mm insulation: RW,R = 48 dB 300 mm insulation: RW,R = 49 dB 2 Concrete roofing tiles 30 mm support battens 40/60 mm counter battens 120 mm Ultratherm 3 Concrete roofing tiles 30 mm support battens 40/60 mm counter battens 22 mm Multiplex-top 4 Concrete roofing tiles 30 mm support battens 40/60 mm counter battens 35 mm Multiplex-top

4 F 30

140 mm insulation: RW,R = 46dB 200 mm insulation: RW,R = 47 dB 300 mm insulation: RW,R = 48 dB

140 mm insulation: RW,R = 44 dB 200 mm insulation: RW,R = 47 dB 300 mm insulation: RW,R = 47 dB

140 mm insulation: RW,R = 44 dB 200 mm insulation: RW,R = 46 dB 300 mm insulation: RW,R = 47 dB

Interior panelling

140 mm insulation: RW,R = 47 dB 200 mm insulation: RW,R = 48 dB 300 mm insulation: RW,R = 49 dB

140 mm insulation: RW,R = 49 dB 200 mm insulation: RW,R = 51 dB 300 mm insulation: RW,R = 51 dB 140 mm insulation: RW,R = 47 dB 200 mm insulation: RW,R = 49 dB 300 mm insulation: RW,R = 50 dB

140 mm insulation: RW,R = 48 dB 200 mm insulation: RW,R = 51 dB 300 mm insulation: RW,R = 51 dB 140 mm insulation: RW,R = 46 dB 200 mm insulation: RW,R = 48 dB 300 mm insulation: RW,R = 49 dB

140 mm insulation: RW,R = 48 dB 200 mm insulation: RW,R = 50 dB 300 mm insulation: RW,R = 51 dB 140 mm insulation: RW,R = 46 dB 200 mm insulation: RW,R = 48 dB 300 mm insulation: RW,R = 49 dB

140 mm insulation: 140 mm rafters + insulation RW,R = 45 dB 15 mm timberboard 200 mm insulation: 60 mm Thermowall-gf or TherRW,R = 46 dB moroom 300 mm insulation: 5 mm plaster RW,R = 47 dB 140 mm rafters + insulation 27 mm sprung rod 15 mm timberboard 15 mm PF 2 x 12.5 mm GF 140 mm rafters + insulation 27 mm sprung rod 15 mm timberboard 4 x 12.5 mm GF

8 F 90

140 mm insulation: RW,R = 55 dB 200 mm insulation: RW,R = 56 dB 300 mm insulation: RW,R = 57 dB

140 mm insulation: RW,R = 57 dB 200 mm insulation: RW,R = 59 dB 300 mm insulation: RW,R = 60 dB

140 mm insulation: RW,R = 56 dB 200 mm insulation: RW,R = 59 dB 300 mm insulation: RW,R = 59 dB

140 mm insulation: RW,R = 56 dB 200 mm insulation: RW,R = 58 dB 300 mm insulation: RW,R = 59 dB Fire and noise insulation

Intermediate values may be determined by linear interpolation.


Further detailed information on applications, fastening systems for the materials to be used, structural analyses, connections and fittings can be found in the general building inspection certificate no. P-SAC 02/III-371 and report no. 1753849-1.

GUTEX Construction Recommendations P. 49

7. Fire and noise insulation


7.3 Exterior wall Supporting, enclosing exterior wall in fire resistance class F 30/F90-B, from inside and F90-B, from outside
Plaster facade, timber upright construction Bay insulation:
Product GUTEX Thermoflex Cellulose insulation (Isofloc or Dmmstatt) Mineral wool, fusion point 1000C Glass wool Thickness (mm) 160 160 160 160 Raw density (kg/m) 30 45 30 18

Construction: Solid construction timber min. 160 x 60 mm, a 62.5 cm

Position 1 2 Thermowall-gf d 60 mm RW,R = 40 dB RW,R = 40 dB RW,R = 40 dB RW,R = 40 dB RW,R = 41 dB RW,R = 42 dB RW,R = 45 dB

Exterior panelling F90 GUTEX plaster system d 7 mm Thermowall d 100 mm RW,R = 44 dB RW,R = 44 dB RW,R = 44 dB RW,R = 44 dB RW,R = 46 dB RW,R = 47 dB RW,R = 50 dB Thermowall-gf d 60 mm (bolted) RW,R = 44 dB RW,R = 44 dB RW,R = 44 dB RW,R = 44 dB RW,R = 45 dB RW,R = 46 dB RW,R = 48 dB Thermowall-gf d 40 mm (bolted) Non-flammable panelling d 12.5 mm RW,R = 40 dB RW,R = 40 dB RW,R = 40 dB RW,R = 40 dB RW,R = 41 dB RW,R = 42 dB RW,R = 45 dB

Position

1 BPB board d 9.5 mm BPB board d 12.5 mm Plaster fibreboard d 12.5 mm

2 HWP* d 15 mm HWP* d 12 mm HWP* d 12 mm PBP board d 12.5 mm Plaster fibreboard d 12.5 mm Inst. level Variant A Inst. level Variant B Plaster fibreboard d 12.5 mm PBP board d 18 mm

3 HWP* d 15 mm Plaster fibreboard d 12.5 mm HWP* d 15 mm HWP* d 15 mm

Interior panelling

F30

BPB board d 9.5 mm Plaster fibreboard d 10 mm BPB board d 9.5 mm Plaster fibreboard d 12.5 mm Plaster fibreboard d 12.5 mm PBP board d 18 mm

F90

RW,R = 41 dB RW,R = 41 dB

RW,R = 46 dB RW,R = 46 dB

RW,R = 45 dB RW,R = 45 dB

RW,R = 41 dB RW,R = 41 dB

Installation level Variant A: with GUTEX Thermoinstal Installation level Variant B: with battens 60x60 mm and bay insulation 40 mm

Further detailed information on applications, fastening systems for the materials to be used, structural analyses, connections and fittings can be found in the general building inspection certificate no. P-SAC 02/III-321.

P. 50 GUTEX Construction Recommendations

7. Fire and noise insulation


7.3 Exterior wall Supporting, enclosing exterior wall in fire resistance class F 30/F90-B, from inside and F90-B, from outside
Facades not rear-ventilated Timber upright construction Bay insulation:
Product GUTEX Thermoflex Cellulose insulation (Isofloc or Dmmstatt) Mineral wool, fusion point 1000C Glass wool Thickness (mm) 160 160 160 160 Raw density (kg/m) 30 45 30 18

Construction: Solid construction timber min. 160 x 60 mm, a 62.5 cm


Position 1 Facade not rearventilated d 14 mm Thermowall-gf or Ultratherm d 60 mm (bolted) HWP d 15 mm RW,R = 36 dB RW,R = 36 dB RW,R = 36 dB RW,R = 36 dB RW,R = 38 dB RW,R = 39 dB RW,R = 41 dB RW,R = 38 dB RW,R = 38 dB Exterior panelling F90 Facade not rearventilated d 14 mm Thermowall-gf d 40 mm (bolted) Non-flammable panelling d 12.5 mm RW,R = 40 dB RW,R = 40 dB RW,R = 40 dB RW,R = 40 dB RW,R = 43 dB RW,R = 43 dB RW,R = 45 dB RW,R = 43 dB RW,R = 43 dB RW,R = 41 dB RW,R = 41 dB RW,R = 41 dB RW,R = 40 dB RW,R = 43 dB RW,R = 44 dB RW,R = 46 dB RW,R = 44 dB RW,R = 44 dB Facade not rearventilated d 14 mm Thermowall d 100 mm (bolted)

Position

1 BPB board d 9.5 mm BPB board d 12.5 mm Plaster fibreboard d 12.5 mm

2 HWP d 15 mm HWP d 12 mm HWP d 12 mm PBP board d 12.5 mm Plaster fibreboard d 12.5 mm Inst. level Variant A Inst. level Variant B Plaster fibreboard d 12.5 mm PBP board d 18 mm

3 BPB board d 9.5 mm Plaster fibreboard d 12.5 mm HWP d 15 mm HWP d 15 mm

Interior panelling

BPB board d 9.5 mm Plaster fibreboard d 10 mm HWP d 15 mm Plaster fibreboard d 12.5 mm Plaster fibreboard d 12.5 mm PBP board d 18 mm F90 F30

Installation level Variant A: with GUTEX Thermoinstal Installation level Variant B: with battens 60x60 mm and bay insulation 40 mm

Further detailed information on applications, fastening systems for the materials to be used, structural analyses, connections and fittings can be found in the general building inspection certificate no. P-SAC 02/III-321. Available for download at www.gutex.de

GUTEX Construction Recommendations P. 51

Fire and noise insulation

7. Fire and noise insulation


7.3 Exterior wall Supporting, enclosing exterior wall in fire resistance class F 30/ F90-B, from inside and F90-B, from outside
Plastered facade/rear-ventilated facade Solid wood walls

Position 1 2 Position 1 BPB board d 9.5 mm BPB board d 12.5 mm Plaster fibreboard d 12.5 mm Interior panelling F30 BPB board d 9.5 mm Plaster fibreboard d 10 mm HWP d 15 mm Plaster fibreboard d 12.5 mm Plaster fibreboard d 12.5 mm PBP board d 18 mm 2 HWP d 15 mm HWP d 12 mm HWP d 12 mm PBP board d 12.5 mm Plaster fibreboard d 12.5 mm Inst. level Variant A Inst. level Variant B Plaster fibreboard d 12.5 mm PBP board d 18 mm 3 BPB board d 9.5 mm Plaster fibreboard d 12.5 mm HWP d 15 mm HWP d 15 mm

Exterior panelling F90 GUTEX plaster system d 7 mm Thermowall-gf d 60 mm RW,R = 35 dB RW,R = 35 dB RW,R = 35 dB RW,R = 35 dB RW,R = 35 dB RW,R = 37 dB RW,R = 40 dB Thermowall d 100 mm RW,R = 38 dB RW,R = 38 dB RW,R = 38 dB RW,R = 38 dB RW,R = 38 dB RW,R = 40 dB RW,R = 43 dB Rear-ventilated facade/facade not rear-ventilated (bolted) d 14 mm Ultratherm d 120 mm RW,R = 45 dB RW,R = 45 dB RW,R = 45 dB RW,R = 45 dB RW,R = 45 dB RW,R = 47 dB RW,R = 50 dB Multiplex-top d 20 mm Thermosafehomogen d 120 mm RW,R = 45 dB RW,R = 45 dB RW,R = 45 dB RW,R = 45 dB RW,R = 45 dB RW,R = 47 dB RW,R = 50 dB

F90

RW,R = 35 dB RW,R = 35 dB

RW,R = 38 dB RW,R = 38 dB

RW,R = 45 dB RW,R = 45 dB

RW,R = 45 dB RW,R = 45 dB

Installation level Variant A: with GUTEX Thermoinstal Installation level Variant B: with battens 60x60 mm and bay insulation 40 mm
Further detailed information on applications, fastening systems for the materials to be used, structural analyses, connections and fittings can be found in the general building inspection certificate no. P-SAC 02/III-321.

P. 52 GUTEX Construction Recommendations

7. Fire and noise insulation


7.3 Exterior wall Supporting, enclosing exterior wall in fire resistance class F30-B, from inside and from outside

Plastered facade

Rear-ventilated facade

The structure can be composed with one variant of the individual layers.

Exterior panelling Layer 1 Mineral render d 6 mm Layer 2 GUTEX Thermowall-gf d 40 mm 210 kg/m GUTEX Thermowall d 80 mm 160 kg/m GUTEX Multiplextop d 28 mm 200 kg/m GUTEX Ultratherm d 40 mm 190 kg/m

Support structure

Bay insulation Layer 1 GUTEX Thermoflex d 140 mm 30 kg/m or Cellulose insulation (Isofloc or Dmmstatt) d 140 mm 45 kg/m or Mineral wool, fusion point 1000C d 140 mm 30 kg/m or Glass wool d 140 mm 18 kg/m Timberboard d 15 mm 550 kg/m

Interior panelling Layer 2 Installation level Optional Layer 3 PB d 9.5 mm or PB d 95 mm or plaster fibreboard (Xella,Knauf, Rigips) d 10 mm Timberboard d 12 mm 550 kg/m Plaster fibreboard (Xella,Knauf, Rigips) 12.5 mm Installation level Optional PB d 12.5 mm or PB d 12.5 mm or Plaster fibreboard (Xella,Knauf, Rigips) d 12.5 mm Plaster fibreboard (Xella,Knauf, Rigips) d 10 mm

Mineral render d 6 mm

Solid construction timber B x H 140 x 60 mm a 625 mm

Rear-ventilated facade

Installation level Optional

Rear-ventilated facade

Facing structures for outside wall can be combined with the facing structures for inside wall

Further detailed information on applications, fastening systems for the materials to be used, structural analyses, connections and fittings can be found in the general building inspection certificate no. P-SAC 02/III-321.

GUTEX Construction Recommendations P. 53

Fire and noise insulation

7. Fire and noise insulation


7.4 Partition wall and/or party wall
To DIN 4109: R'W 57 dB, to DIN 4102-02: F 30-B, from inside to outside and F 90-B from outside to inside Timber upright construction/solid timber construction Variant 1:
Joint Interior panelling Bay insulation Exterior panelling Construction Installation level

Variant 2:

The structure can be composed with one variant of the individual layers Interior panelling:
Product Timberboard + PB Timberboard + PBF Timberboard + PF Timberboard + PB Timberboard + PBF Timberboard + PF PF + PF Thickness (mm) 15 + 9.5 15 + 9.5 15 + 10 12 + 12.5 12 + 12.5 12 + 12.5 12.5 + 10 Raw density (kg/m) 500 500 500 500 500 500

Interior panelling:
Product Timberboard + PB Timberboard + PBF Timberboard + PF PF + PF Thickness (mm) 15 + 9.5 15 + 9.5 15 + 10 12.5 + 10 Raw density (kg/m) 500 500 500

Bay insulation:
Product GUTEX Thermoflex GUTEX Thermosafe-homogen Cellulose insulation Mineral wool, fusion point 1000C Glass wool Thickness (mm) 160 160 160 160 160 Raw density (kg/m) 35 80 45 30 18

Bay insulation:
Product GUTEX Thermoflex GUTEX Thermosafe-homogen Cellulose insulation Mineral wool, fusion point 1000C Glass wool Thickness (mm) 160 160 160 160 160 Raw density (kg/m) 35 80 45 30 18

Construction: Solid construction timber min. 160 x 60 mm, a 62.5 cm Exterior panelling:
Product GUTEX Thermowall-gf + Render layer Thickness (mm) 60 6 Raw density (kg/m) 210 700

Construction: Solid construction timber min. 160 x 60 mm, a 62.5 cm Exterior panelling:
Product GUTEX Thermowall-gf + Render layer Thickness (mm) 60 6 Raw density (kg/m) 210 700

Joint 120 mm:


Product GUTEX Thermoflex Mineral wool, fusion point 1000C Glass wool Thickness (mm) 80 80 80 Raw density (kg/m) 35 30 18

Joint 100 mm:


Product GUTEX Thermoflex Mineral wool, fusion point 1000C Glass wool Thickness (mm) 80 80 80 Raw density (kg/m) 35 30 18

Installation level in accordance with general building inspection certificate no. P-172 34405-ift.
Further detailed information on applications, fastening systems for the materials to be used, structural analyses, connections and fittings can be found in the general building inspection certificate no. P-172 34405-ift.

P. 54 GUTEX Construction Recommendations

7. Fire and noise insulation


7.4 Partition wall and/or party wall
To DIN 4109: R'W 57 dB, to DIN 4102-02: F 30-B, from inside to outside and F 90-B from outside to inside

Variant 3:
Joint

Variant 4:

Interior panelling Bay insulation Exterior panelling Construction

The structure can be composed with one variant of the individual layers Interior panelling:
Product Timberboard + PB Timberboard + PBF Timberboard + PF Timberboard + PB Timberboard + PBF Timberboard + PF PF + PF Thickness (mm) 15 + 9.5 15 + 9.5 15 + 10 12 + 12.5 12 + 12.5 12 + 12.5 12.5 + 10 Raw density (kg/ m) 500 500 500 500 500 500

Interior panelling:
Product Timberboard + PB Timberboard + PBF Timberboard + PF Timberboard + PB Timberboard + PBF Timberboard + PF PF + PF Thickness (mm) 15 + 9.5 15 + 9.5 15 + 10 12 + 12.5 12 + 12.5 12 + 12.5 12.5 + 10 Raw density (kg/ m) 500 500 500 500 500 500

Bay insulation:
Product GUTEX Thermoflex GUTEX Thermosafe-homogen Cellulose insulation Mineral wool, fusion point 1000C Glass wool Thickness (mm) 160 160 160 160 160 Raw density (kg/m) 35 80 45 30 18

Bay insulation:
Product GUTEX Thermoflex GUTEX Thermosafe-homogen Cellulose insulation Mineral wool, fusion point 1000C Glass wool Thickness (mm) 160 160 160 160 160 Raw density (kg/ m) 35 80 45 30 18

Construction: Solid construction timber min. 160 x 60 mm, a 62.5 cm Exterior panelling:
Product PBF/PF/cement-bonded chipboard + GUTEX Thermowall-gf + render layer Thickness (mm) Raw density (kg/m)

Construction: Solid construction timber min. 160 x 60 mm, a 62.5 cm Exterior panelling:
Product Xella HD board + GUTEX Thermowall-gf + Render layer Thickness (mm) 15 40 6 Raw density (kg/m) 210 700

12.5 40 6

210 700

Joint 100 mm:


Product GUTEX Thermoflex Mineral wool, fusion point 1000C Glass wool Thickness (mm) 80 80 80 Raw density (kg/m) 35 30 18

Joint 60 mm:
Product GUTEX Thermoflex Mineral wool, fusion point 1000C Glass wool Thickness (mm) 40 40 40 Raw density (kg/m) 35 Fire and noise insulation 30 18

Further detailed information on applications, fastening systems for the materials to be used, structural analyses, connections and fittings can be found in the general building inspection certificate no. P-172 34405-ift.

GUTEX Construction Recommendations P. 55

7. Fire and noise insulation


7.4 Partition wall and/or party wall
To DIN 4109: R'W 57 dB, to DIN 4102-02: F 30-B, from inside to outside and F 90-B from outside to inside Variant 5:
Joint Interior panelling Bay insulation Exterior panelling Construction

Variant 6:

The structure can be composed with one variant of the individual layers Interior panelling:
Product Timberboard + PB Timberboard + PBF Timberboard + PF Timberboard + PB Timberboard + PBF Timberboard + PF PF + PF Thickness (mm) 15 + 9.5 15 + 9.5 15 + 10 12 + 12.5 12 + 12.5 12 + 12.5 12.5 + 10 Raw density (kg/ m) 500 500 500 500 500 500

Interior panelling:
Product Timberboard + PB Timberboard + PBF Timberboard + PF Timberboard + PB Timberboard + PBF Timberboard + PF PF + PF Thickness (mm) 15 + 9.5 15 + 9.5 15 + 10 12 + 12.5 12 + 12.5 12 + 12.5 12.5 + 10 Raw density (kg/ m) 500 500 500 500 500 500

Bay insulation:
Product GUTEX Thermoflex GUTEX Thermosafe-homogen Cellulose insulation Mineral wool, fusion point 1000C Glass wool Thickness (mm) 160 160 160 160 160 Raw density (kg/ m) 35 80 45 30 18

Bay insulation:
Product GUTEX Thermoflex GUTEX Thermosafe-homogen Cellulose insulation Mineral wool, fusion point 1000C Glass wool Thickness (mm) 160 160 160 160 160 Raw density (kg/ m) 35 80 45 30 18

Construction: Solid construction timber min. 160 x 60 mm, a 62.5 cm Exterior panelling:
Product PBF/PF/cement-bonded chipboard + GUTEX Thermowall-gf Thickness (mm) 12.5 60 Raw density (kg/ m)

Construction: Solid construction timber min. 160 x 60 mm, a 62.5 cm Exterior panelling:
Product Xella HD board + GUTEX Thermowall-gf Thickness (mm) 15 60 Raw density (kg/m)

210

210

Joint 60 mm

Joint 60 mm

Further detailed information on applications, fastening systems for the materials to be used, structural analyses, connections and fittings can be found in the general building inspection certificate no. P-172 34405-ift.

P. 56 GUTEX Construction Recommendations

7. Fire and noise insulation


7.4 Partition wall and/or party wall
To DIN 4109: R'W 57 dB, to DIN 4102-02: F 30-B, from inside to outside and F 90-B from outside to inside Variant 7:
Joint Interior panelling Bay insulation Exterior panelling Construction

Variant 8:

The structure can be composed with one variant of the individual layers Interior panelling:
Product Timberboard + PB Timberboard + PBF Timberboard + PF Timberboard + PB Timberboard + PBF Timberboard + PF PF + PF Thickness (mm) 15 + 9.5 15 + 9.5 15 + 10 12 + 12.5 12 + 12.5 12 + 12.5 12.5 + 10 Raw density (kg/ m) 500 500 500 500 500 500

Interior panelling:
Product Timberboard + PB Timberboard + PBF Timberboard + PF Timberboard + PB Timberboard + PBF Timberboard + PF PF + PF Thickness (mm) 15 + 9.5 15 + 9.5 15 + 10 12 + 12.5 12 + 12.5 12 + 12.5 12.5 + 10 Raw density (kg/ m) 500 500 500 500 500 500

Bay insulation:
Product GUTEX Thermoflex GUTEX Thermosafe-homogen Cellulose insulation Mineral wool, fusion point 1000C Glass wool Thickness (mm) 160 160 160 160 160 Raw density (kg/ m) 35 80 45 30 18

Bay insulation:
Product GUTEX Thermoflex GUTEX Thermosafe-homogen Cellulose insulation Mineral wool, fusion point 1000C Glass wool Thickness (mm) 160 160 160 160 160 Raw density (kg/ m) 35 80 45 30 18

Construction: Solid construction timber min. 160 x 60 mm, a 62.5 cm Exterior panelling:
Product MDF + GUTEX Thermowall-gf + render layer Thickness (mm) 15 40 6 Raw density (kg/ m) 210 700

Construction: Solid construction timber min. 160 x 60 mm, a 62.5 cm Exterior panelling:
Product MDF + GUTEX Thermowall-gf Thickness (mm) 15 60 Raw density (kg/ m) 210

Joint 60 mm

Joint 60 mm:
Product GUTEX Thermoflex Mineral wool, fusion point 1000C Glass wool Thickness (mm) 40 40 40 Raw density (kg/ m) 35 Fire and noise insulation 30 18

Further detailed information on applications, fastening systems for the materials to be used, structural analyses, connections and fittings can be found in the general building inspection certificate no. P-172 34405-ift.

GUTEX Construction Recommendations P. 57

7. Fire and noise insulation


7.4 Partition wall and/or party wall
To DIN 4109: R'W 57 dB, to DIN 4102-02: F 30-B, from inside to outside and F 90-B from outside to inside Variant 9:
Joint Interior panelling Bay insulation Exterior panelling Construction

Variant 10:

The structure can be composed with one variant of the individual layers Interior panelling:
Product Timberboard + PB Timberboard + PBF Timberboard + PF Timberboard + PB Timberboard + PBF Timberboard + PF PF + PF Thickness (mm) 15 + 9.5 15 + 9.5 15 + 10 12 + 12.5 12 + 12.5 12 + 12.5 12.5 + 10 Raw density (kg/ m) 500 500 500 500 500 500

Interior panelling:
Product PBF Timberboard + PF PF + PF Thickness (mm) 18 12 + 15 12.5 + 10 500 Raw density (kg/ m)

Bay insulation:
Product GUTEX Thermoflex GUTEX Thermosafe-homogen Cellulose insulation Mineral wool, fusion point 1000C Glass wool Thickness (mm) 160 160 160 160 160 Raw density (kg/ m) 35 80 45 30 18

Bay insulation:
Product GUTEX Thermoflex GUTEX Thermosafe-homogen Cellulose insulation Mineral wool, fusion point 1000C Glass wool Thickness (mm) 80 80 80 80 80 Raw density (kg/ m) 35 80 45 30 18

Construction: Solid construction timber min. 160 x 60 mm, a 62.5 cm Exterior panelling:
Product PF + PF PBF + PBF Thickness (mm) 15 + 15 18 + 18 Raw density (kg/ m) 500 500

Construction: Solid construction timber min. 80 x 60 mm, a 31.3 cm Exterior panelling:


Product PF + PF PBF + PBF Thickness (mm) 15 + 15 18 + 18 Raw density (kg/m) 500 500

Joint 40 mm

Joint 150 mm:


Product GUTEX Thermoflex Mineral wool, fusion point 1000C Thickness (mm) 2 x 60 2 x 50 Raw density (kg/m) 35 30

Further detailed information on applications, fastening systems for the materials to be used, structural analyses, connections and fittings can be found in the general building inspection certificate no. P-172 34405-ift.

P. 58 GUTEX Construction Recommendations

7. Fire and noise insulation


7.4 Partition wall and/or party wall
To DIN 4109: R'W 57 dB, to DIN 4102-02: F 30-B, from inside to outside and F 90-B from outside to inside Variant 11:
Joint Interior panelling

Variant 12:

Exterior panelling Construction

The structure can be composed with one variant of the individual layers Interior panelling:
Product Timberboard + PB Timberboard + PBF Timberboard + PF Timberboard + PB Timberboard + PBF Timberboard + PF PF + PF Thickness (mm) 15 + 9.5 15 + 9.5 15 + 10 12 + 12.5 12 + 12.5 12 + 12.5 12.5 + 10 Raw density (kg/ m) 500 500 500 500 500 500

Interior panelling:
Product Timberboard + PB Timberboard + PBF Timberboard + PF Timberboard + PB Timberboard + PBF Timberboard + PF PF + PF Thickness (mm) 15 + 9.5 15 + 9.5 15 + 10 12 + 12.5 12 + 12.5 12 + 12.5 12.5 + 10 Raw density (kg/ m) 500 500 500 500 500 500

Construction: Laminated timber element 100 mm Exterior panelling:


Product GUTEX Thermowall-gf GUTEX Thermowall Thickness (mm) 60 100 Raw density (kg/m) 210 165

Construction: Laminated timber element 100 mm Exterior panelling:


Product PF + PF + GUTEX Thermowall-gf one-sided* PF + PBF + GUTEX Thermowall-gf one-sided*
* Only on one wall side as per drawing

Thickness (mm) 15 + 15 60 18 + 18 60

Raw density (kg/ m) 500 210 500 210

Joint 50 mm

Joint 50 mm

Further detailed information on applications, fastening systems for the materials to be used, structural analyses, connections and fittings can be found in the general building inspection certificate no. P-172 34405-ift.

GUTEX Construction Recommendations P. 59

Insulation against the heat in summer GUTEX wood insulation boards protect living areas from high temperatures, in particular, areas under roofs. Thanks to their high thermal storage capacity, they effectively dampen the flow of warmth from exterior to interior areas. Wood has a specific thermal storage capacity of 2100 J/kgK, which is the highest amongst all insulation materials. Insulation against the cold in winter Effective insulation reduces heating bills and creates a comfortable living environment in winter. Due to their low thermal conductivity (D = 0.037 W/mK), GUTEX insulating wood fibreboards provide optimum insulation in winter, protecting the interior of houses from heat loss and ingression of cold. Pleasant indoor environment GUTEX wood fibre insulation boards are vapour permeable ( = 3), regulating the living environment with their ability to absorb and release up to 15 % of their weight in moisture without the loss of their insulation capacity. Acoustic insulation The open-pore structure of GUTEX wood fibreboards and their high absorption volume contribute to their ability to deliver superb soundproofing against airborne and impact noise. Fire protection GUTEX wood fibre insulation boards easily comply with fire protection regulations. Various individual certificates of approval are available for F30-B to F90-B fire resistance ratings for roof and wall structures. Environmental compatibility The raw material for all GUTEX insulation boards comes from wood that is locally harvested and

grown using sustainable forestry management practices. GUTEX exclusively uses untreated spruce and fir chips and shavings, which are by-products obtained from other timber manufacturing processes. All GUTEX insulation boards are tested and certified as biologically safe and compatible with other building materials (natureplus seal of quality). Recyclability GUTEX wood fibreboards are completely recyclable and, provided wood preservatives have not contaminated them, can be disposed of at the nearest recovery centre. User friendly GUTEX insulation boards are manufactured according to the highest quality standards and are characterised by absolutely minimum dimensional deviation. This, combined with the detailed installation instructions provided by the manufacturer, makes working with GUTEX products a pleasure. Made in Germany For more than 80 years, GUTEX, a family owned and operated company, has manufactured insulation boards at its plant in Waldshut-Tiengen, which is located in the southern Black Forest. All GUTEX insulation boards carry the CE and U marks and are produced according to the current applicable standards.GUTEXs external thermal insulation system (ETICS) is approved by the German building authorities. GUTEX customer service An important part of GUTEXs customer service is its qualified assistance. Whether you require help with a private single-family house or commercial property, GUTEXs trained and qualified staff will gladly assist you.If you have technical queries, please contact our technical assistance department by phone +49-7741/60 99-125, fax +49-7741/60 99-21 or per e-mail at anwendungstechnik@gutex.de. GUTEX product training Architects, craftsmen, wholesalers, sales staffs and developers can benefit from the workshops GUTEX offers, which address specific topics, including physics and building, construction techniques, product applications, etc.Visit our Web site for further information or give us a call.

Your stockist / Advisor:

Images and graphics: GUTEX Archive


Updated 10/2012

GUTEX Holzfaserplattenwerk | Gutenburg 5 | D-79761 Waldshut-Tiengen | Tel: +49 7741/60 99-0 | Fax: +49 7741/60 99-57 | www.gutex.de | Email: info@gutex.de

You might also like