You are on page 1of 3

MCB Distribution Boards

tra Combinations

MCB Distribution Boards Single Phase with 125A Busbar, A-Type


General Incoming options: 2 Pole Main switch, 2 Pole RCD, 100A Direct Connection Terminal Block Applicable standard BS EN 60439-3 / EN 50298

Technical Data
Electrical Data Busbar nominal rating 125A Busbar short circuit withstand 16kA fuse Rated voltage 240V AC 50/60Hz Maximum incomer rating 100A Maximum outgoing device 63A Safety class I Electromagnetic compatibility enviroment 1 Maximal amount of heat to be dissipated FGA6 26 W FGA12 34 W FGA19 45 W Mechanical Data Ingress protection rating Paint finish

Limits of operation Enclosure steel gauge Gland plate Maximum cable capacity: Neutral bar 16mm2 Earth bar 16mm2 Main earth termination 16mm2 Incomers and outgoers: RCBO 25mm2 RCD 63A: 25mm2, 80-100A: 50mm2 MCB 25mm2 Switch disconnectors: Z-SM 50mm2 Weight FGA6 8.5 kg FGA12 11 kg FGA19 13 kg Material: Plastic parts Support for busbar Noryl SE1 Cover for busbar PVC grey Cover for neutral wire PVC transparent Hinge roller Polyamide Rotary lever lock Polyamide Metal parts Console for devices ST 37 1.00 mm galvanized Casing ST 37 1.25 mm Lid ST 37 1.25 mm Door ST 37 1.25 mm Mounting plate ST 37 1.5 mm Busbar copper E-Cu 58 Neutral- and earth busbar MS 58 All screws are galvanized and passivated Environmental conditions: Ambient temperature -5 to +40C Average ambient temperature over 24 hours 35C Relative air humidity 50% at 40C

IP40 when the door is closed IP2X when the door is open RAL 7035 textured, epoxy powder coated 40C ambient 50% RH 1.5mm 1 blank and 1 with knockouts

Dimensions (mm)
FGA 6 FGA 12 FGA 19

MCB Distribution Boards


tra Combinations

Three Phase with 250A Busbar, B-Type


General Additional bolt-on spreader boxes/service enclosures and incomer section Incoming options: 3 or 4 Pole Main switch, 4 Pole RCD or Direct Connections Applicable standard BS EN 60439-1 and 3 / EN 50298

Technical Data
Electrical Data Busbar nominal rating Busbar Short circuit withstand 250A 16kA ... 1.2 sec. 22kA ... 0.5 sec. Rated voltage 415V ac 50/60Hz Maximum incomer rating Internal device - 125A External device - 250A Maximum feeder rating 63A Safety class I Electromagnetic compatibility enviroment 1 Maximal amount of heat to be dissipated FGB4 and 6 71 W FGB8 and 12 95 W FGB18 and 24 119 W FGBES 47 W FGBEX 68 W Mechanical Data Ingress protection rating Paint finish IP40 when the door is closed and IP2X when the door is open RAL 7035 textured, epoxy powder coated 40C ambient 50% RH 1.5mm 1 blank and 1 with knockout

Limits of operation Enclosure steel gauge Gland plates Maximum cable capacity: Neutral bar 70mm2 Earth bar 70mm2 Main earth termination 70mm2 Incomers and outgoers: RCBO 25mm RCD 63A: 25mm2, 80-100A: 50mm2 MCB 25mm2 Switch disconnectors: LCB1/HSD1 120mm2 Z-SM 50mm2 Weight FGB4 11 kg FGB6 12 kg FGB8 14 kg FGB12 15 kg FGB18 20 kg FGB24 22 kg FGES 8.5 kg FGEX 11 kg Material: Plastic parts Busbar casing Noryl SE1 Support for inputs Noryl SE1 Cover for inputs Noryl SE1 Cover for neutral wire PVC transparent Hinge roller Polyamide Rotary lever lock Polyamide Metal parts Mounting rail for extension-box Aluminium Console ST 37 1 mm galvanized Casing ST 37 1.25 mm Lid ST 37 1.25 mm Door ST 37 1.25 mm Mounting plate ST 37 1.5 mm Busbar copper E-Cu 58 All screws are galvanized and passivated Environmental conditions: Ambient temperature -5 to +40C Average ambient temperature over 24 hours 35C Relative air humidity 50% at 40C

MCB Distribution Boards


tra Combinations

Dimensions (mm)
FGB 4/ -6 FGB 8/ -12 FGB 18/ -24

Dimensions Accessories (mm)


Spreader Box FGBES Spreader Box FGBEX

Incomer Enclosure FGB-INC125/250

Modular Service Box FGBSM19

You might also like