You are on page 1of 46

ANT-5 PDH/SDH/SONET Field Tester

Acterna ANT-5
SDH/PDH Access Tester
© 2005 JDS Uniphase Corporation.
2
All rights reserved. Company & Confidential
ANT-5 – The Fully Integrated Field Tester

SDH
PDH

ATM
SONET

No restriction !

Any unit is configurable with all the above technologies

ƒ Weight: < 2.5 kg


ƒ Dimensions: 197 mm x 76 mm x 275 mm

© 2005 JDS Uniphase Corporation.


3
All rights reserved. Company & Confidential
What Is An ANT-5:-

It is:-
• A very compact field test solution
• An easy to use SDH/SONET/ATM handheld tester

It has:-
• PDH, SDH, SONET from 1.5M to 2.5G in one instrument
• All Interfaces built-in – which means NO adapters
• Optimized test philosophy to reduce user costs
• Superb off-line viewer for easy report generation
• An ATM Option that supports ATM on all rates
• Upgrade paths from electrical only to STM-1/-4/-16 optical

© 2005 JDS Uniphase Corporation.


4
All rights reserved. Company & Confidential
ANT-5 All This Capability In A Single Package

ANT-5
ANT-5 can
can test
test all
all interfaces
interfaces in
in the
the network:-
network:-
Installation,
Installation,Commissioning
CommissioningMaintenance,
Maintenance,Fault
FaultFinding
Finding
© 2005 JDS Uniphase Corporation.
5
All rights reserved. Company & Confidential
ANT-5 Key Benefits

• Very compact field test solution (Size & Weight)


• The easiest to use SDH handheld on the market
• PDH, SDH, SONET - 1.5M to 2.5G in one instrument
• All Interfaces built-in (no adapters)
• Designed to minimise cost of ownership
• Off-line viewer for easy report generation
• ATM Option available on all rates
• 3 hour battery life for optical tests
• Upgrade paths – “future proof investment”

© 2005 JDS Uniphase Corporation.


6
All rights reserved. Company & Confidential
ANT-5 Installations made simpler !

• “Big OK” results summary speeds up installation tasks


• Split screen: results & set-up simultaneously
• Permanent LED's, animated Icons, beeper with alarms
• All errors counted simultaneously

© 2005 JDS Uniphase Corporation.


7
All rights reserved. Company & Confidential
SDH Optical Fiber Installation

ƒ Verify Connectivity
$ Quick BER test at fiber interface
$ Verify optical power level at Rx side

STM-1/4/-16 o

STM-1/4/16o

© 2005 JDS Uniphase Corporation.


8
All rights reserved. Company & Confidential
SDH Network Element Installation
ƒ Verify network element setup
$ PerformanceTest mappings & alarm response
ƒ Verify proper timing STM-1e / 155 Mbps
$ Check tolerance
to tributary clock offset

e.g. DS3/ 45 MBit/s

© 2005 JDS Uniphase Corporation.


9
All rights reserved. Company & Confidential
SDH Commissioning
ƒ Verify Quality of service
$ Performance Analysis to international standards
ƒ Verify network backup
$ APS tests
ƒ Verify 3rd party network routing
$ RTD measurements

Performance verification against:


G.821, G.826, G.828, G.829, ANSI, M.2100, M.2101

© 2005 JDS Uniphase Corporation.


10
All rights reserved. Company & Confidential
SDH Maintenance
ƒ In service verification
– Monitoring alarms/errors, OH bytes, Pointer, TCM
ƒ Check for tributary problems
$ Use VC12 tributary scan for a fast overview

ANT-5 provides NRZ ECL port for monitoring of STM-1/-4/-16 signals


(electr. conversion done by specific NE.
© 2005 JDS Uniphase Corporation.
11
All rights reserved. Company & Confidential
ATM 3G/UMTS network qualification

2 Mbit/s / STM-1 ATM qualification


between Node B and ATM switch

RNC
NB

MUX MUX ATM

Utopia interface
loop on VPI/VCI
Test: - ATM BERT (HCOR, HUNC, CLR, CMR,CER)
- Delay (CTD, CDV)
- ATM throughput,
- right VPI/VCI configuration
© 2005 JDS Uniphase Corporation.
12
All rights reserved. Company & Confidential
FY06 Activities

© 2005 JDS Uniphase Corporation.


13
All rights reserved. Company & Confidential
ANT-5 Optimized test philosophy

1. Setup instrument: select structure, mapping, timer


2. Select application (APS, RTD….)
3. Select Actions (Alarm / Error/ Pointer generation)
4. Select Result View (OK screen, Alarm/Error list, Histogram)
5. START Test / STOP Test
6. Analyze Result (OK / alarms / errors)
7. Store results / configuration
8. Transfer results / configurations
9. Report Generation (off-line)

© 2005 JDS Uniphase Corporation.


14
All rights reserved. Company & Confidential
SETUP Main Page

# Signal Structure
# Application
# OH Setup
# Measurement Timer

© 2005 JDS Uniphase Corporation.


15
All rights reserved. Company & Confidential
SETUP Signal structure

ƒ Start with RX
– Select Test type (Terminated, In-line monitor, Thru-mode1) )
– Select Interface
– Select Timing (internal, external)
– Select AU mapping
– Select Container
– Select PDH Setup (Rate, Tributary, Mode)
– Select Test Pattern

ƒ Copy Rx -> TX

1) available with SW Release 10.x

© 2005 JDS Uniphase Corporation.


16
All rights reserved. Company & Confidential
SETUP …or use Auto Configuration

ƒ Select input level (ITU/High or PMP/Low)


ƒ Auto Configuration checks:
– interface (SDH, SONET, PDH ,ATM)
– mapping structure
– payload

© 2005 JDS Uniphase Corporation.


17
All rights reserved. Company & Confidential
SETUP Available PDH interfaces

ƒ PDH interfaces
– T1 (bantam)
– E1 interface unbalanced (BNC)
E1 interface balanced (RJ-48)
– DS3, E3, E4
interface unbalanced (BNC)

ƒ Supporting framed structures:


PCM-30, PCM-30C, PCM31, PCM31C

© 2005 JDS Uniphase Corporation.


18
All rights reserved. Company & Confidential
SETUP Available SDH Mappings

ƒ Transmitted over STM-1e, STM-1o, STM-4o, STM-16o

© 2005 JDS Uniphase Corporation.


19
All rights reserved. Company & Confidential
SETUP Application Selection

# Performance Analysis
# Repetitive BERT
# APS
# OH Capture
# Delay
# Tributary Scan

© 2005 JDS Uniphase Corporation.


20
All rights reserved. Company & Confidential
SETUP Application Perf. Analysis

• Guarantee link performance to end customer


– G.821, G.826, G.828, G.829
– ANSI, M.2100, M.2101
• Perf. tests on SDH substructure / PDH interfaces
• User defined test duration
• Test results exportable to PC using CSV & ASCII
© 2005 JDS Uniphase Corporation.
21
All rights reserved. Company & Confidential
SETUP Application Repetitive BER

• For the testing of Radio Links


• Results used for Carrier to Noise ratios

© 2005 JDS Uniphase Corporation.


22
All rights reserved. Company & Confidential
SETUP Application APS

ƒ Operates at SDH and PDH interfaces


ƒ MS-AIS, AU-AIS,TU-AIS & TSE sensors
ƒ Service Disruption sensor

ƒ 1 mS resolution
ƒ User programmable limits
ƒ Pass/Fail Indication
ƒ Results can be
printed/exported

© 2005 JDS Uniphase Corporation.


23
All rights reserved. Company & Confidential
SETUP Application RTD

Key measurement used during installation & fault


finding
– Check routing of 3rd party provided circuits
– Satellite hop line up test
– Latency checking of cross connects
– Connectivity testing
– Regenerator loop checks

ƒ Measurement range up to 10s


ƒ Resolution: +/- 1uS except…
– E1 PDH +/- 100uS
– E1 SDH VC12 +/- 100uS
– E2 +/1 10uS
– VC11/VC12 Bulk +/- 10uS

© 2005 JDS Uniphase Corporation.


24
All rights reserved. Company & Confidential
ACTION Main Page

# Alarm / Error generation


# OH manipulation
# Pointer generation
# TCM generation 1)

© 2005 JDS Uniphase Corporation.


25 1) available with SW Release 10.x
All rights reserved. Company & Confidential
ACTION Alarm / Error generation

# TSE errors
# PDH / SDH Defects
# SDH anomalies

© 2005 JDS Uniphase Corporation.


26
All rights reserved. Company & Confidential
ACTION OH manipulation

Hex-format or Descriptor
according to Ring / Linear structure
© 2005 JDS Uniphase Corporation.
27
All rights reserved. Company & Confidential
ACTION Pointer Generation

ƒ Manipulates AU and/or TU pointer


ƒ INC rements and DEC rements
ƒ Single and Contineous

© 2005 JDS Uniphase Corporation.


28
All rights reserved. Company & Confidential
ANT-5 START / STOP measurement

START
/
STOP

© 2005 JDS Uniphase Corporation.


29
All rights reserved. Company & Confidential
RESULTS Main Page

ƒ Result Analysis (OK)


ƒ Defect Panel
ƒ Event Log
ƒ Annomaly Count
ƒ Graph

ƒ OH Analysis
ƒ Pointer Analysis
ƒ Performance Analysis
ƒ APS result
ƒ TCM Analysis

© 2005 JDS Uniphase Corporation.


30
All rights reserved. Company & Confidential
RESULTS Alarm & Event analysis
• OK / Alarm/Event screen: shows results & set-up simultaneously
• Defect Panel monitors overhead alarms
• Anomaly page indicates counts & ratios
• Event Log timestamps all events (res.: 100 ms)
• Histogram incl. Zoom function

© 2005 JDS Uniphase Corporation.


31
All rights reserved. Company & Confidential
RESULTS OH Analysis & Path tracing

ƒ Key OH bytes are displayed in Hex or text format


ƒ Interpreter works network structure dependant (linear or ring)
ƒ Bytes not currently used are greyed out

© 2005 JDS Uniphase Corporation.


32
All rights reserved. Company & Confidential
RESULTS Byte Capturing

ƒ Captures K1 & K2-Byte (APS)


ƒ Considers selected
network structure
- Ring G.841
- Linear G.783

ƒ Trigger :
- manual
- compare
- not compare

© 2005 JDS Uniphase Corporation.


33
All rights reserved. Company & Confidential
RESULTS Pointer Analysis

ƒ Detects AU and TU Pointer actions


– Current pointer values
– No. of INCrements/DECrements
– No. of NDFs
– Average deviation from nominal (in +/- ppm)

ƒ Recorded with event log

© 2005 JDS Uniphase Corporation.


34
All rights reserved. Company & Confidential
Store results

ƒ Store / Autostore results and configurations on hard disc


either
csv-format (for implementation with spreadsheets)
or
ANT-5 specific format: .a5R or .a5c

© 2005 JDS Uniphase Corporation.


35
All rights reserved. Company & Confidential
Transfer results
ƒ Most convenient: Using the CF card !
Direct readable with any Labtop with PCMCIA slot !
Easy readable with Desktops using card readers !

Results

Configurations

© 2005 JDS Uniphase Corporation.


36
All rights reserved. Company & Confidential
Report generation…

…via ANT-5 Off-line


Viewer:
- load results
and
- print on your office printer

© 2005 JDS Uniphase Corporation.


37
All rights reserved. Company & Confidential
OPTION PDH Mux /DeMux

ƒ PDH Mux/DeMux testing of legacy PDH systems


ƒ Transmit/Receive at 2, 34 and 140 Mbps
ƒ Test signals at 64Kbps, 2,8,34,140 Mbps
ƒ structured signals from nx64k to 140M
– Structure depth
(nx64, E1, E2, E3)
ƒ E1 Sa-bit (Tx/Rx)
generation and analysis

© 2005 JDS Uniphase Corporation.


38
All rights reserved. Company & Confidential
OPTION Concatenated Mapping

ƒ Eanables concatenated mappings

© 2005 JDS Uniphase Corporation.


39
All rights reserved. Company & Confidential
OPTION Remote Operation (GUI)

ƒ …via ANT-5 Ethernet port:-


– Install Remote Operation Client
on PC / Laptop
– Establish connection
– Easy operation (GUI simuation)
– No additional user training required
– ROC is Master; Remote unit will act as a Slave
(measurements run as long as connection is established)
ƒ No need to develop SCPI control programs
– Enables FTP of results and configurations

© 2005 JDS Uniphase Corporation.


40
All rights reserved. Company & Confidential
OPTION Remote Control / SCPI

ƒ Application:
generating automatic test procedure for manufacturing, lab or
NE-evaluation processes
ƒ Using SCPI command over the serial interface

© 2005 JDS Uniphase Corporation.


41
All rights reserved. Company & Confidential
OPTION SONET Mapping

ƒ Transmitted over STS-1, OC-3, OC-12, OC-48

© 2005 JDS Uniphase Corporation.


42
All rights reserved. Company & Confidential
OPTION AU-3 / VT Mapping

ƒ enables lower order mapping

© 2005 JDS Uniphase Corporation.


43
All rights reserved. Company & Confidential
OPTION ATM

ƒ ATM carried over PDH / SDH / SONET over all interface rates
ƒ ATM cell generation ( 2 PVCs, UNI and NNI mode)
ƒ ATM load: CBR, VBR ( bandwith, burst length, burst gap)
ƒ ATM cells: O.191 test cells, ATM BERT (AAL-0), background
ƒ Alarm & Error insertion (HEC, VP-AIS, VP-RDI, VC-AIS, VC-RDI)
ƒ ATM QoS measurements (CER, CLR, CTD, CDV)
ƒ ATM Statistics (Utilization, cell counts, HEC error ratio)
ƒ ATM Channel Explorer (detects automatically active VCI, VPI)
© 2005 JDS Uniphase Corporation.
44
All rights reserved. Company & Confidential
OPTION ATM

ƒ ATM carried over PDH (E1, E3, DS-1,DS3, E4)

ƒ ATM carried over SDH


– STM-n VC-11/TU-11, STM-n VC-11/TU-12, STM-n VC-12
– STM-n VC-3, STM-n VC-4
– STM-4/16 VC4-4c

ƒ ATM carried over SONET


– VT-1.5 SPE, VT-2 SPE
– STS-1 SPE
– STS-3c SPE,STS-12c SPE

ƒ UNI and NNI PVC operation


© 2005 JDS Uniphase Corporation.
45
All rights reserved. Company & Confidential
ANT-5 Installations made simpler !
• “Big OK” results summary speeds up installation tasks
• Split screen: results & set-up simultaneously

• Permanent LED's, animated Icons, beeper with alarms


• All errors counted simultaneously

© 2005 JDS Uniphase Corporation.


46
All rights reserved. Company & Confidential

You might also like