Applicator Sizing - Flow

Project :
Customer: Contact person: C.Project No.: Phone: eMail: Fax: 0

TAG : FE/FIT-402A / FE/FIT-402B


Timestamp: Sales order number: 29.07.2013 07:36 PM Review number: 2

Sizing Sheet
General Parameters
Fluid State Character Abrasivity Fluid Group (PED) LPG (70% Propane, 30% Butane) Liquid Clean Not abrasive Dangerous Fluid (Fluid group 1) Atmospheric Pressure Standard 1.0132 bar_a ANSI/ASME

Operating Conditions
minimum Requested Flow Pressure Temperature Density Viscosity Sound Velocity Pressure (min/max) Temp. (min/max) Vapor Pressure 13 13 2.4652 3.1255 10 000 nominal 20 000 14 17 593.35 0.18849 870 16 20 3.7129 maximum 40 000 USBPD_petro kg/cm2_g C kg/m3 cP m/s kg/cm2_g C kg/cm2_a

Flowmeter : Promass 84F


Flow Principle Meter Size Minimum Flow Maximum Flow Material (sensor) * Process connection* PED category ** : Coriolis (Promass) 4" 0 USBPD_petro 89 043.5 USBPD_petro SS 1.4539/904L, ext.temp. Cl 300 ANSI / 316L/1.4404 ASME B16.5 flange Application is Cat. II

Extended order code


Qty 1 Item Flowmeter Promass 84F Description 84F1H-PABS Extended order code

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

Print date: 29.07.2013 07:49 PM Applicator: 10.15.03 / 124

-1/3-

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - Flow


Project :
Customer: Contact person: C.Project No.: Phone: eMail: Fax: 0

TAG : FE/FIT-402A / FE/FIT-402B


Timestamp: Sales order number: 29.07.2013 07:36 PM Review number: 2

Sizing Sheet
Sizing and Calculated Results
minimum Requested Flow Pressure loss Velocity (meas. tube) Measured error Vol.*** Measured error Mass*** Meas. error MassPremiumCal*** Reynolds No. 10 000 0.02 4.469 0.1 0.1 0.05 nominal 20 000 0.1 8.938 0.1 0.1 0.05 1 440 539 maximum 40 000 0.38 17.88 0.1 0.1 0.05 USBPD_petro kg/cm2 m/s % % %

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.

Warnings / Messages

Print date: 29.07.2013 07:49 PM Applicator: 10.15.03 / 124

-2/3-

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - Flow


Project :
Customer: Contact person: C.Project No.: Phone: eMail: Fax: 0

TAG : FE/FIT-402A / FE/FIT-402B


Timestamp: Sales order number: 29.07.2013 07:36 PM Review number: 2

Chart Sheet
Flowmeter : Promass 84F
Flow Principle Meter Size Minimum Flow Maximum Flow Coriolis (Promass) 4" 0 USBPD_petro 89 043.5 USBPD_petro

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.

Print date: 29.07.2013 07:49 PM Applicator: 10.15.03 / 124

-3/3-

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).