You are on page 1of 4

Sanitary Turbine Flowmeters

Accurate, Versatile, and Economical


Description
Flow Technologys sanitary turbine flowmeters provide accuracy, versatility and economy in measuring a wide variety of food, beverage and pharmaceutical products. Flow Technologys more than 30 years experience enables the company to produce an extremely durable sanitary turbine flowmeter with a repeatability of 0.1%. The SA Series Sanitary Turbine Flowmeters feature 316 stainless steel construction and have a smooth finish, which is designed to eliminate cracks and crevices where bacteria breed. Standard flowmeters are available in sizes from 1/2" to 2" with sanitary clamps. Flow rates range from 0.1 to 250 gallons per minute (0.38 to 946 LPM). Typical applications include measuring or batch controlling water, WFI, USP water, deionized water, vaccines, clean pharmaceuticals, milk, cream, vegetable oil, wine, beer, spirits, soft drinks, juices (without pulp) and any other clean, consumable liquid.

Sanitary Turbine Flowmeters


Stainless Steel Construction

Features
Available in sizes from 1/2" to 2" with sanitary clamp Flow rates from 0.1 to 250 gallons per minute (GPM) Temperature ranges up to 350 F (177 C) 316 stainless steel construction Magnetic or modulated carrier (RF) pickoffs available Exceptional repeatability of 0.1% NIST traceable calibrations Withstands clean-in-place (CIP) and sterilize-in-place (SIP) processes Compatible with all Flow Technology electronics Ceramic bearings for long life

Flowmeter Cut-Away
SA-24

Specifications
Repeatability Linearity
0.1% of reading 0.5% of reading over the normal 10:1 flow range Note: SA4-8 is 2% of reading 100 microns 510 mS to step change Less than 10 psi for max. flow in water 250 psig/17.2 bar g 350 F (177 C) 202000 Hz typical (depends on model) 3/4" clamp/0.98" O.D. 1-1/2" clamp/1.98" O.D. 2" clamp/2.51" O.D.

Pickoff Coil Magnetic Transmission distance:

Maximum Particle Size Response Time Pressure Drop Max. Pressure Max. Temperature Frequency Range Sanitary Clamps T1 T2 T3

300 ft. (91 meters) without pre-amplifier DC coil resistance: 2275 ohms, nominal Minimum output voltage: 10 mV 30 ft. (9 meters) maximum to carrier amplifier 12 ohms, nominal

Modulated Carrier Transmission distance: DC coil resistance: MS Connector 2-pin, standard pickoff: 3-pin, amplified pickoff:

Pickoff Electronic Mating Connections


15-89515-101 15-89515-102

Threaded Connection with Leads Junction Box with Terminal: 73-31836-105

Tapered End Fittings The I.D. of the Flow Technology sanitary meters are designed with a taper in the end fitting to provide a smooth transition from the meter bore to standard size mating tubing. The standard Tapered to Line Size is provided in the Model Numbering System chart.

SIP Considerations

Dynamic steaming of 5 minutes or less is recommended for maximum life expectancy 25 Ra 30 Ra

Surface Finish
Bore Internals

Dimensions

Standard Configuration

U T N L K F
Used On Line Size Clamp Size Code

45 .039 .036 .302 .300 2.450 .988 .980 .037 .035 SA4-8 .5"

45 .012 .009 .372 .370 2.450 .988 .980 .037 .035 SA6-8

45 .092 .089 .442 .440 2.450 .988 .980 .037 .035 SA-08 .75"

45 .187 .184 .504 .502 3.250 1.988 1.980 .035 .030 SA-10

50 .130 .127 .565 .563 3.250

45 .012 .009 .862 .860 3.56

50 .157 .154 1.002 1.000 4.060

45 .030 .027 1.317 1.315 4.590 1.988 1.980 .052 .048 SA-24

45 .059 .056 1.753 1.751 6.060 2.520 2.512 .072 .068 SA-332 2" 2" T3

1.988 1.988 1.988 1.980 1.980 1.980 .035 .030 SA-12 1" 1.5" T2 .045 .037 SA-16 .049 .044 SA-20

1.5"

.75" T1

Optional Configuration

U T N L K F
Used On Line Size Clamp Size Code

45 .030 .026 .504 .502 3.25 .988 .980 .035 .030 SA-10

45 .030 .026 .565 .563 3.25 .988 .980 .035 .030 SA-12

60 .166 .163 .302 .300 2.450 1.988 1.980 .037 .035 SA4-8

60 .144 .141 .372 .370 2.450 1.988 1.980 .037 .035 SA6-8 1" 1.5" T2

60 .126 .134 .442 .440 2.450

60 .150 .147 .862 .860 3.56

60 .110 .107 1.002 1.000 4.06 2.520 2.512 .049 .044 SA-20 2" 2" T3

60 .163 .160 1.317 1.315 4.59 2.520 2.512 .052 .048 SA-24

1.988 2.520 1.980 2.512 .037 .035 SA-08 .045 .037 SA-16

.75" .75" T1

Model Numbering System


Tapered Basic Clamp to Line Model Size No. Standard Optional Meter I.D. In.
0.30 0.30 0.37 0.37 0.44 0.44 0.50 0.50 0.56 0.56 0.86 0.86 1.00 1.00 1.32 1.32 1.75

Normal 10:1 Nominal Extended Flow Range Size Flow Range Max Freq. GPM LPM RF MIN MAG MIN All MAX Hz MIN MAX MIN MAX GPM LPM GPM LPM GPM LPM
.25 .50 2.50 5.00 .95 9.50 .10 .15 .25 .38 .57 .95 .12 .20 .3 .4 .5 1.0 1.5 2.5 3.5 .45 .76 1.1 1.5 1.9 3.8 5.7 9.5 13.2 3 5 10 15 25 60 100 160 250 11 19 38 57 95 227 380 606 946 2000 2100 2000 2000 2000 2000 1950 1500 1300

SA4-8 SA6-8 SA-08 SA-10 SA-12 SA-16 SA-20 SA-24 SA-32

T1 = .75" T2 = 1.5" T1 = .75" T2 = 1.5" T1 = .75" T2 = 1.5" T2 = 1.5" T1 = .75" T2 = 1.5" T1 = .75" T2 = 1.5" T3 = 2.0" T2 = 1.5" T3 = 2.0" T2 = 1.5" T3 = 2.0" T3 = 2.0" -

0.5" 1.0" 0.5" 1.0" .75" 1.0" 1.0" .75" 1.0" .75" 1.0" 2.0" 1.5" 2.0" 1.5" 2.0" 2.0"

1.90 19.00

1.00 10.00 3.80 38.00 1.25 12.50 4.70 47.0 2 5 9 15 22 20 50 90 150 225 7.60 76.0 19 34 57 83 190 340 570 830

.30 1.10 .50 1.90 1.0 1.0 1.6 2.5 3.8 3.8 6.1 9.5

Special Designator
Special designator to be assigned by factory when required. Examples: 316 L SS, special tapering or other special modifications.

Sanitary Clamp Sizes


T1 = 3/4" clamp T2 = 1 1/2" clamp T3 = 2" clamp Note: See above chart for line size.

Pickoff
1 = RF, 2-pin connector 2 = Magnetic, 2-pin connector 5 = RF, 1/2" NPT for mounting electronics 3 = Magnetic, 1/2" NPT for mounting electronics

Calibration Range
N = 10 points normal 10:1 X = 10 points extended Y = 20 points extended

Calibration Fluid
W = Water B = Viscosity blend

Journal Bearings
G = Ceramic

Calibration Units
= Standard U = Units other than GPM R = Range other than normal or extended B = Both units and range other than standard

Materials of Construction
Code E H Housing 316SS 316SS Rotor 430F 17-4*

Fluid Type
L = Liquid * Non-Standard

Specifications are for reference only and are subject to change without notice.

Local Representative:

8930 S. Beck Ave., Ste 107, Tempe, Arizona 85284 USA Tel: (480) 240-3400 Fax: (480) 240-3401 Toll Free: 1-800-528-4225 E-mail: ftimarket@ftimeters.com Web: www.ftimeters.com DB 62046 Rev E 2004 FTI Flow Technology, Inc. Printed in USA