You are on page 1of 3

AL RAJHI STEEL

(CUT & BEND PROCESSING BUILDING)


INDUSTRIAL CITY JEDDAH, KINGDOM OF SAUDI ARABIA

BILL OF QUANTITY (CIVIL & STRUCTURAL)

Prepared by:
Prepared by Saudi Designers Engineering Consultants

P.O. Box 7953, Dammam 31472 Kingdom of Saudi Arabia Tel. No. 8346778 / 8340840 Fax No. 8326594 Email : saudidesigners@sdec.com.sa IQ NET & DIN EN ISO 9001 : 2000 Cert. Registration No. 356682 QM

Project Title : CUT & BEND PROCESSING BUILDING ( RAJHI STEEL ) Location : INDUSTRIAL CITY, JEDDAH KSA Subject : BILL OF QUANTITY - CIVIL/STRUCTURAL (Revision-1) UNIT QTY. U/RATE TOTAL (SR) (SR)

ITEM NO.

CIVIL WORKS
I MOBILIZATION Site preparation and provision of temporary site facilities, fence, project sign board etc. II a) 1 2 3 SITE WORKS Earthworks Clearing, levelling and stabilisation of the site. Excavation for building foundation including dewatering & shoring. Disposal of unsuitable materials off site. Backfilling works arround sides of foundation, grade beams and Trenches including structure sweet sand back filling up to sub grade level, compacted to 95% of relative density for sand according to modified proctor test. Sand or Gravel moult Around Buildings. Backfilling works under Sand or Gravel moult. Interlocking Side walks. Standard curpstones for side walks. Asphalt Works ( Road Ways & Parking Area ) Asphalt Layers (70 mm Asphalt Wearing coarse fine aggregate + sprayed liquid Asphalt + 150 mm BASE COURSE compacted with water & roller 95 to 100% compaction PROCTOR STANDARD TEST + 300 mm SUB BASE A4-2 95 to 100% compaction). 2 Layers each 300 mm SUB GRADE 95% compaction. BUILDING WORKS CONCRETE WORKS Lean concrete 50mm thk below isolated footing and grade beam, FC:2500psi. Reinforced concrete isolated footing, FC: 4500 psi. Reinforced concrete pedestal, FC: 4500 psi. Reinforced concrete columns, FC: 4500 psi. Reinforced concrete grade beam, FC: 4500 psi. Reinforced concrete grade slab including slab thickening, FC: 4500 psi Reinforced concrete for beams (drop & hidden) of roof Hordi slab, FC: 4500 psi Reinforced concrete for Hordi slab/ribs for roof, FC: 4500 psi Reinforced concrete for cantilever slab & HVAC pad, FC: 4500 psi. LS LS LS 1.00 1.00 1.00 LS 1.00

M3

5180.00

5 6 7 8 b)

M2 M3 M2 M

6100.00 6715.00 465.00 475.00

M2

5730.00

2 III a) 1 2 3 4 5 6 7 8 9

M3

3440.00

M3 M3 M3 M3 M3 M3 M3 M2 M3

57.00 379.00 54.00 33.00 142.00 750.00 57.00 490.00 10.50

BOQ Civil / Structural : CUT AND BEND BUILDING ( RAJHI STEEL ) Page 1 of 2

Saudi Designers Engineering Consultants

Project Title : CUT & BEND PROCESSING BUILDING ( RAJHI STEEL ) Location : INDUSTRIAL CITY, JEDDAH KSA Subject : BILL OF QUANTITY - CIVIL/STRUCTURAL (Revision-1) UNIT Reinforced concrete for ramps & entry porch, FC: 4500 psi. lean concrete for side walks around Buildings, FC: 2500 psi. Standard curpstones for side walks. Reinforced concrete for water tank, FC: 4500 psi. Reinforced concrete for Pump Room, FC: 4500 psi. Lean concrete below water tank, FC: 2500 psi. Reinforced concrete for Trenches, FC: 4500 psi. Lean concrete 100mm under Trenches, FC: 2500 psi. Isolation joint. Control joint. Expansion joint. WATER PROOFING AND MOISTURE PROTECTION Vapor barrier 250 microns polyethylene sheets below footing footing, grade beam, grade slab and Trenches. Bituminous paint 2 coats to concrete surface in direct contact with the ground. 250 mm width waterstop for Water tank. 250 mm width waterstop for Trenches. Chekered Plate Covering Trenches. Rag polt Supports Chekered Plates. Water proofing membrane 4mm thk two layers with two coats of bitumen paint for Trenches. Water proofing membrane 4mm thk two layers with two coats of bitumen paint for water tank. Protection Blocks for Water Tank. ERECTION / INSTALLATION ONLY Erection of Steel Structure including all accessories, mechanical ventillators, roof curbs, louvers, doors, cage ladder, crane girder and etc. M3 M3 LM M3 M3 M3 M3 M3 LM LM LM M2 M2 LM LM M2 LM M2 M2 M2 QTY. 18.00 41.00 380.00 20.00 2.50 4.00 160.00 35.00 1155.00 475.00 291.00 5400.00 2385.00 19.00 32.00 135.00 410.00 410.00 70.00 30.00 U/RATE TOTAL (SR) (SR)

ITEM NO. 10 11 12 13 14 15 16 17 18 19 20 IV 1 2 3 4 5 6 7 8 9 V 1

LS

1.00

BOQ Civil / Structural : CUT AND BEND BUILDING ( RAJHI STEEL ) Page 2 of 2

Saudi Designers Engineering Consultants

You might also like