Process Engineering

Analysis

Adaptions

3 4 5 6

Production Identification Estimation Input Feeding Quality Checking

Steps Engineering To Check if Schueco MSE-210 & MSE-100 are suitable for Indian Conditions

To Design MSE-100 and MSE-210 as per Indian Codes To Understand critical components To Identify of Local Fabricator To Estimate local cost of production based on primary Inputs To Estimate Time required for BOM production To feed-in ready for construction drawings and acceptable tolerance levels inputs To prepare prototype To approve prototype on tolerance and finishing aspects

No

Yes

Reengineering Back to S.No.2 Production of parts with Different item number

Final Production With Same Item

Status

Local Consultant been identified and Quotation Received for job work

Local Fabricator been identified and Quotation Received for job work Inputs required Inputs required Inputs required

Comments Design Analysis shall be done as per IS 875 which is different than DIN codes as it specifies 3 Sec wind where in DIN specifies 10 Sec wind conditions It is recommended to check structures for 44 and 47 m/s wind speeds in Terrian-3 and 4 Category with Building Heights up to 40 Mtrs These critical Components are basically Load Bearing members thus require lowest tolerence lavels Al divison approved Fabricator Primary analysis shows that Production cost is-----less 1 Month time to produce 100 kWp BOM Pls provide inputs of ------components Shall be submitted once produced Shall be submitted once produced

Basic Load on Rooftop due to Solar Installation S.No. Component Value Unit 1 Weight of the Mounting Structure 40 kg/m2 2 Weight of the Modules 27 kg/m2 3 Wind Pressure 0 kg/m2 4 Total 67 kg/m2 5 Safety Factor 1.3 kg/m2 6 Net 84 kg/m2 7 Net 1 kN/m2 Sample Calculation of Design Wind Speed as per IS 875 for CISCO rooftop structures Input Data Discription Value Unit Remarks Height of Building 8 Mtrs NA Basic Wind Speed 47 m/s As per IS 875 Wind Map Terrain Zone 3 Category As per IS 875 Wind Map Structure Length 20-50 mtrs Life Span 25 Years Expected Life Span of Solar Rooftop Wind Load Description Values Vz VbXk1Xk2Xk3 Vz Design wind speed at any height m/s To be determined kl Probability factor ( risk coeffi.cient) 0.94 k2 Terrain, height and structure size Factor 0.88 k3 Topography factor 1 Vb Basic Wind Speed 47 Vz 38.88 M/s s pz .6Vz^2 Kg/m^2 pz 906.92 N/m2 At 12 Degree Tilt PzXcos(12 pz on roof N/m^2 pz on roof N/m^2 Disclaimer

Nature Static Static Daynamic

Remaks

As per IS 875 As per IS 875 As per IS 875 As per IS 875

1 2 3

Above Values is for estimation purposes and subject to change in case building Structural Designer wish to incorporate additional loads Above needs to be submitted to Building Structural Engineer We shall be doing a detail analysis after getting in principal approval from Building Engineers

Pressure coeffcients tilt 12 deg Pressure in Zone A Suction in Zone A Pressure in Zone B Suction in Zone B Pressure in Zone C Suction in Zone C WL P in zone A/B S in zone A/B P in zone C S in zone C Pressure Load on AB 1523.622 N/m 1616.309 N/m A

0.3 1160.855 -1469.207 2285.433 -1958.943 1523.622 -2049.635 N/m2 N/m2 N/m2 N/m2 N/m2 N/m2 0.5

Va Vb 1616.3091 1042.774 -1667.5501 -1417.78 1523.622 1523.622 -2049.6347 -2049.63

N/m N/m N/m N/m

1523.622 N/m

distance b/w longitudinal channels Suction Load on AB -2049.63 N/m -1667.55 N/m A B -2049.6347 N/m

distance b/w longitudinal channels

0.5 B D

Pressure Load on CD 1523.622 N/m 1042.774 N/m C D 1523.622 N/m

distance b/w longitudinal channels Pressure Load on CD -2049.63 N/m -1417.78 N/m C D -2049.63 N/m

distance b/w longitudinal channels