Chapter 1 About This Manualintroduces the manual purpose and structure, and the scope of users. Chapter 2 Overview of Commissioning introduces the M2000 system
Chapter 3 Commissioning of O&M Network introduces how to commission the O&M network, including how to configure each network device and port. Chapter 4 Access of NEs to M2000 introduces how to access NEs to the M2000 system and verify the access. Chapter 5 Commissioning of Remote Alarm Notification Service introduces how to commission the remote alarm notification service. Chapter 6 Commissioning of Alarm Box introduces how to install and set the alarm box, and how to verify its operation. Chapter 7 Commissioning of Alarm Plate introduces how to install and set the alarm plate, and how to verify its operation.
Huawei Technologies Proprietary 1
Chapter 8 Commissioning of Dial-Up Connection introduces how to commission the dial-up connection and verify its operation.
1.4 References
This manual refers to the following documents:
iManager M2000 Mobile Element Management System Hardware Installation Manual iManager M2000 Mobile Element Management System Software Installation Manual iManager M2000 Mobile Element Management System HA System Hardware Installation Manual iManager M2000 Mobile Element Management System HA System Software Installation Manual iManager M2000 Mobile Element Management System Operation Manual
Figure 1.1 External devices connected to the M2000 The external devices are connected to the M2000 in two ways:
Through the serial port cable. These devices include modem and the alarm box. The devices, the M2000 server and clients compose the M2000 system in a broad sense.
Through the TCP/IP-based O&M network. These devices include NEs and network connection devices managed by network management system (NMS) and M2000, such as the cross multiplex device, LAN switch, router and firewall.
Table 1.1 M2000 system commissioning procedure No. 1 Step Commission the O&M network. Purpose Construct the O&M network, and make sure that the M2000 communicates with NE devices and the upper NMS through TCP/IP. 2 Cover various NEs into the management of the M2000 system. Install the mediation software for each NE to access the M2000 system, and set up management objects for these NEs to operate on and maintain them through the M2000. 3 Commission modem and the remote alarm notification function. 4 Commission the alarm box or plate. Make sure that the alarm box or plate gives audio or visual alarm accordingly. Chapter 6 Commissioning of Alarm Box Chapter 7 Commissioning of Alarm Plate 5 Commission the dial-up connection. Make sure that the remote user can use the PSTN network to log in to the M2000 system through dial-up. Chapter 8 Commissioning of Dial-Up Connection Make sure that the alarm information can be sent to users in SMSs and E-mails. Chapter 5 Commissioning of Remote Alarm Notification Service Chapter 4 Access of NEs to M2000 Reference Chapter 3 Commissioning of O&M Network
Figure 1.1 LAN star networking diagram Figure 1.1 is a general networking diagram. It omits details about connecting some network devices such as the router.
To set up communication channels from the M2000 to NodeB through RNC, you need to set routes to the NodeB. You should set these routes in two ways:
Through the router. Refer to 3.5Configuring Quidway 2501 Router for setting the router. Through the M2000 server. Configure the default static route or multiple routes
on the M2000 server. For details, refer to M2000 Administrator Guide or M2000 HA System Administrator Guide.
Figure 1.1 Partial E1/T1 networking mode Table 1.1 shows the commissioning procedure for the partial E1/T1 networking mode. Table 1.1 Commissioning procedure for the partial E1/T1 networking No. 1 Operation Use network cables to connect the M2000 server, clients and various NEs to the LAN switch in the public network. Refer to Table 1.1 to connect and configure devices in the M2000 system (such as the disk array, local console and SC) in the private network. 2 Configure the LAN switch. User manual of the LAN switch 3 Configure the router at the NE side. 3.5Configuring Quidway 2501 Router Reference
No. 4
Reference 3.6Configuring Quidway 3640 Router 3.4Configuring Timeslot Cross Device Mercury 3600 3.3Setting Firewall Port
Figure 1.1 Whole E1/T1 networking mode Table 1.1shows the commissioning procedure for the whole E1/T1 networking mode. Table 1.1 Commissioning procedure for the whole E1/T1 networking No. 1 Operation Use network cables to connect the M2000 server, clients and various NEs to the LAN switch in the public network. Refer to Table 1.1 to connect and configure devices in the M2000 system (such as the disk array, local console and SC) in the private network.
Huawei Technologies Proprietary 5
Reference -
No. 2
I. Filtering Traffic
The firewall filters traffic through a set of security check rules. It allows only network data that meets set conditions to pass, and thus ensuring the network security. In the O&M network, the device type, quantity and the type of traffic between device nodes are limited and specific. This makes it possible to set the firewall to filter invalid traffic. In the O&M network, the valid traffics include:
Data stream between the M2000 server and various NEs Data stream between the M2000 server and various clients Data stream between the M2000 server and the NMS Data stream between LMT and devices Data stream for updating virus codes
Protecting against the Land attack Protecting against the Smurf attack Protecting against the Fraggle attack Protecting against the WinNuke attack Protecting against the SYN Flood attack Protecting against the ICMP Flood attack Protecting against the UDP Flood attack Controlling ICMP redirection packets Controlling ICMP destination unreachable packets Protecting against the address scan attack Protecting against the port scan attack Controlling IP packets with the source site option Controlling IP packets with the route record option Enabling the Tracert packet control Protecting against the Ping of Death attack Protecting against the Teardrop attack Checking validity of TCP packets Checking IP fragmentation packets Controlling oversize ICMP packets
Port numbers 0-1023 are for identifying some standard services, such as FTP, Telnet, SMTP and TFTP. Port numbers 1024-49151 are for Internet Assigned Number Authority (IANA) to assign to registered applications. Port numbers 49152-65535 are private and can be assigned dynamically to any applications.
According to various networking security requirements, you can set the firewall:
Between the M2000 server and various NEs. For details about setting the firewall port, refer to 3.3.3Setting Ports Between M2000 Server and NEs. Between the M2000 server and clients. For details about setting the firewall port, refer to 3.3.4Setting Ports Between M2000 Server and Clients. Between the M2000 server and the NMS. For details about setting the firewall port, refer to 3.3.5Setting Ports Between M2000 Server and NMS.
Open some ports at the NE side to any port at the M2000 server side, so that any port at the server side can access ports at the NE side behind the firewall. Open some ports at the M2000 server side to any port at the NE side, so that any port at the NE side can access ports at the server side behind the firewall.
Table 1.1 lists the ports to open at the NE side. Table 1.1 Port numbers used by NE services NE type RNC UDP port 123 TCP port 20, 21, 23, 6000, 6001, 6002, 6007, 6021, 6022, 6088, 6099, 6100 and 16002 CG 123 20, 21, 23, 6000, 6001, 6002, 6007, 6010, 6099, 6100 and 16002 HLR 123 20, 21, 23, 6000, 6001, 6002, 6005, 6006, 6007, 6008, 6009, 6099 and 16002 MGW 123 20, 21, 23, 6000, 6001, 6002, 6006, 6007, 6010, 6099, 6100 and 16002 GGSN 123 20, 21, 23, 6000, 6001, 6006, 6099, 6100 and 16002 SGSN 123, 161 and 162 NodeB IWF 123 123 20, 21, 23, 5000, 6000, 6001, 6002, 6006, 6099, 6100, 6101 and 16002 20, 21, 23, 6000, 6001, 6006 and 6007 20, 21, 23, 7000, 7001, 7005, 7007, 7011, 7021, 7099 and 16002 MSC Server 123 20, 21, 23, 6000, 6001, 6002, 6004, 6005, 6006, 6007, 6008, 6009, 6099 and 16002 IP device 161 and 162 BSC GT800 BSC MSC 8888 8888 8888
Huawei Technologies Proprietary 8
NE type HLR36 PCU/PCU33 CHLR iMSC tMSC CBSC CMSC PDSN RAC MSCe
TCP port
6000, 6001 and 6002 6000, 6001 and 6002 21, 6000, 6001, 6002 and 6009 6000, 6001 and 6002 21, 6000, 6001, 6002 and 16002 21, 6000, 6001, 6002 and 6009 123 20, 21, 23, 6000, 6001, 6002, 6004, 6005, 6006, 6007, 6008, 6009, 6099 and 16002
POC GLMS
Table 1.2 describes the use of each port. Table 1.2 Use of ports used by NE services Port type TCP Port No. 20 and 21 Use For loading NE software, and uploading and downloading software and logs 23 6000 For maintaining the Telnet service For the M2000 to deliver maintenance commands and for the NE to respond 6001 6002 6099 16002 For the NE to report alarm data For the NE to report performance data For the NE to report configuration data For the NE to report performance data covering all counters
Port type
Use For communication with BAM For the alarm box, commissioning and binary packets, depending on the NE type
UDP
Table 1.3 lists the ports to open at the M2000 server side and their use. Table 1.3 Number and use of ports used by services on the M2000 server for connecting NEs Port type TCP Port No. 20 21 UDP 123 For FTP control For FTP data For synchronizing the NTP time Use
Open some ports at the M2000 server side to any port at the M2000 client side, so that any port at the client side can access ports at the server side behind the firewall.
Open some ports at the M2000 client side to any port at the M2000 server side, so that any port at the server side can access ports at the client side behind the firewall.
Table 1.1 lists the ports to open at the M2000 server side and their use. Table 1.1 Number and use of ports used by services on the M2000 server for connecting clients Port type TCP Port No. 20 and 21 Use For FTP control and data
Port type 23
Port No.
Use For maintaining the Telnet service For Xserver For the Sun font service For the M2000 log service For the report server For the M2000 audit service For the Kernel monitoring For the TAO CORBA name service For the diagnosis tool For the TAO notification service For application processes of each M2000 service For the M2000 monitoring process For synchronizing the NTP time
6050 7100 7777 8088 and 9088 9025 9990 9999 10119 19999 51001-51016 and 51213-51219 53000 UDP 123
Table 1.2 lists the ports to open at the M2000 client side and their use. Table 1.2 Number and use of ports used by M2000 clients for connecting the M2000 server Port type TCP Port No. 6000 53100 UDP 123 Use For the server to connect when the client runs Winaxe For delivering CORBA events For synchronizing the NTP time
Open some ports at the M2000 server side to any port at the NMS side, so that
any port at the NMS side can access ports at the server side behind the firewall. Table 1.1 lists the ports to open at the M2000 server side and their use. Table 1.1 Number and use of ports used by services on the M2000 server for connecting the NMS Port type TCP Port No. 51221 Use For connecting the CORBA interface of the NMS for the M2000 northbound service 8765 4100 UDP 8001 and 10163 For forwarding M2000 alarms to the NMS For the Sybase database service For the M2000 SNMP service
Figure 1.1 Front view of Mercury 3600 As shown in Figure 1.1, Mercury 3600 has 20 LEDs, one fluorescent 16x2 LCD liquid crystal display, four buttons and one terminal interface on its front panel. The LEDs on the front panel reflects timely the major or minor alarm and the system status, including the number of modules, version, and the current date and time.
4-E1
4-E1
4-E1
4-E1
4-E1
Figure 1.1 Rear view of Mercury 3600 The back panel of Mercury 3600 has five slots for holding interface modules, such as the 4-channel E1 and 2-channel V.35 interface modules, as shown in Figure 1.2.
Figure 1.2 Interface module plug-in Different interface modules provide different types of interfaces. Select the type of modules according to the actual need. Insert the module in the back panel of Mercury 3600 and fix it. To change the module, make sure to switch off the equipment. When the module is inserted tight into the slot, screw tight the module, and then switch on the equipment again.
IV. Performance
Table 1.1 Mercury 3600 basic performance Item Features Description Provide five slots and support up to 16 E1s. Support five access modes: E1, T1, V.35, IDSL and IP. Can be used as CSU/DSU, E1-T1 converter, multi-channel CSU or DACS. Can provide 512x512 timeslots for interchange. Can use the terminal settings. Can use AC or DC power supply. Network interface (E1) Line rate: 2.048 Mbit/s 50 ppm Line code: AMI/HDB3 Input signal: up to ITU-T G.703 Jitter tolerance: up to ITU-T G.823 User equipment interface (V.35/RS530/X.21/RS-449) Clock control Support the E1/T1 port as the master clock source. Support the E1/T1 port as the slave clock source. Provide an internal clock. Provide the clock holdover mode. Support automatic clock mode selection. Power supply AC or DC power supply DC: from -36 V to -72 V AC: 90 240 VAC and 50/60 Hz Physical characteristics Dimension: 43cm x 33cm x 4.4cm (WxHxD) Temperature: 0-50 C Humidity: 0-95% (congelation) Installation: on the 19 rack (for the desktop) Weight: 3 Kg Data rate: Nx64 kbit/s (N = 1-31)
For example:
If you insert a 4-channel E1 interface module in slot 1, 4 channels of E1 links can be accessed, with the interfaces numbered as 1A, 1B, 1C and 1D. If you insert a 2-channel V.35 interface module in slot 2, 2 channels of V.35 links can be accessed, with the interfaces numbered as 2A and 2B.
Caution: Slot 5 shares the same interface resources as slot 4. Set the interfaces to 4A or 4B. Slot 5 is not used when there is still idle interface.
Table 1.1 RJ48 interface cable sequence Pin 1 2 3 4 5 6 7 8 Receiver Receiver + Transmit Transmit + Description
This interface can also use the RJ45 connecter. The cable sequence is the same as described in Table 1.1.
Indicator
I. Planning Scheme
Figure 1.1 shows the timeslot cross scheme for Mercury 3600.
Use idle timeslots in the E1 line from the switch to transmit NMS information. Connect this E1 line with idle timeslots to port 1A on the E1 interface module on Mercury 3600.
Connect the cable from the router to port 2A on the V.35 interface module. Interchange all timeslots at ports 1A and 2A to port 1B. In this way, port 1B integrates all information on ports 1A and 2A. Connect port 1B to the remote E1 network.
Figure 1.1 Mercury 3600 engineering connecting diagram The connection is described as follows:
Insert a 4-channel E1 interface module in slot 1 on the back panel of Mercury 3600. The switch extends a pair of E1 lines with idle timeslots to connect a pair of terminals on the DDF rack in the transmission equipment room. This pair of E1 lines then jumps to port 1A on the E1 interface module. In this way, Mercury 3600 is connected to the switch through port 1A and the corresponding E1 port on the switch. Connect port 1B on this E1 interface module to the transmission equipment, and then connect it to the remote end in the WAN (the E1 network).
Interchange all timeslots at port 1A to port 1B. Insert a 2-channel V.35 interface module in slot 2 on the back panel of Mercury 3600. Connect port 2A on this module to port S (the WAN network port) on the router. Mercury 3600 defines some timeslots at port 2A as channels for transmitting NMS messages, and interchanges these timeslots to port 1B to extend them to the remote end. In this way, port 1B integrates information on both ports 1A and 2A.
At the other end of the network, Mercury 3600 extracts the timeslots for transmitting NMS messages in the same way, and communicates with the corresponding LAN through the router.
3.4.4 Procedure
According to 3.4.3IPlanning Scheme, configure Mercury 3600 as follows:
I. Configuring HyperTerminal
1) A serial port cable with 9-pin connectors at both ends is delivered with Mercury 3600. Use this cable to connect the terminal port on the front panel of Mercury 3600 and the serial port on the PC. 2) Run the HyperTerminal program, and set up a connection. Use the serial port connection, and set the asynchronous transmission protocol for the port. Set the communications parameters as: 19200 bit/s, eight data bits, no check bit, one stop bit, flow control as Xon/Xoff, and no FIFO buffer. 3) Switch on Mercury 3600, and HyperTerminal displays information about Mercury 3600. Now Mercury 3600 enters the inquiry state.
Note: You can use any type of emulation terminal programs, such as the HyperTerminal of Windows 95/98.
MERCURY> LOGB 2) Extract the clock from port 1A. //Make sure to extract the clock on the two Mercury 3600 in
MERCURY> LINK 1A RCRC:0 TCRC:0 4) Define that links at port 1B do not go through CRC.
Huawei Technologies Proprietary 20
MERCURY> LINK 1B RCRC:0 TCRC:0 5) Interchange all timeslots at port 1A to port 1B.
MERCURY> DATA 2A 4 TYPE:4 //For the 2P-DATA module, define that port 2A is a V.35 interface and the bandwidth is 4 timeslots. Or MERCURY> V35 2A 1 2 //For the 2P-V35, define that two timeslots from the first timeslot at port 2A form the bandwidth, and that port 2A is a V.35 interface and is connected to the WAN network port on the router. 7) Interchange timeslots.
MERCURY> XT 2A 0 1B 1 2 //For the 2P-DATA module, interchange timeslot 0 on port 2A and timeslot 1 on port 1B. Altogether interchange two timeslots. Or MERCURY> XT 2A 1 1B 1 2 //For the 2P-V35 module, interchange timeslot 1 on port 2A and timeslot 1 on port 1B. Altogether two timeslots are interchanged and transmitted to the remote end through port 1B as channels for NMS messages. 8) Save all the above commands into the first Profile. //HEXI1 is the file name. It is definable.
MERCURY>LOGB 2) Extract the clock from port 1A. //Extract the clock from the peer-end Mercury 3600 as the
MERCURY>CLK 1A 3)
master clock, so that the two Mercury 3600 use the same clock. Define that links at port 1B do not go through CRC.
MERCURY> LINK 1B RCRC:0 TCRC:0 4) Define that links at port 1A do not go through CRC.
5)
MERCURY> XC 1B 1A 6) Define that one timeslot from timeslot 1 on port 2A uses the V.35 interface standard and is connected to the WAN port on the router. MERCURY> V35 2A 1 2 7) Interchange two timeslots from timeslot 1 at ports 2A and 1A as channels for NMS messages. MERCURY> XT 2A 1 1A 1 2 8) Save all the above commands into the first Profile. //The file name is WGZX. //The system invokes the first Profile automatically on
By now, the two Mercury 3600 at both sides of the network are configured ready. When the physical links work normally, the indicator on the front panel of Mercury 3600 for the connected port turns green.
Note: What is described in this section applies only to the common networking. For more information, refer to related technical documents about Quidway 2501.
Item Voltage input Rated power Power frequency Power input Environment temperature Environment humidity 180-240 V AC 20 W10% 50-60 Hz 1.5 A 0-40 C
Description
10-90%, no congelation
Note: The 16 MB Dynamic Random Access Memory (DRAM) works as the master memory, and the 2 MB Flash Memory is used to store system programs and configuration files.
IV. Interfaces
Figure 1.1 shows interfaces on Quidway 2501 and the cable connection.
1 2
4 (1) AC power supply (3) Port AUX for connecting the simulated modem (5) WAN port for connecting the digital modem (2) Port Console for connecting the serial port on the computer (4) LAN port for connecting the LAN
Table 1.1 describes these interfaces in detail. Table 1.1 Interface description Name CONSOLE Type RJ45 Standards RS232 Baud rate 9600 Use For system configuration AUX RJ45 RS232 300-115.2 K For supporting modem dial-up for backup Ethernet RJ45 AUI (DB-15) EtherLandII EtherLandSNAP 10 M LAN port, for communications with devices in LAN WAN1 (Serial0) and WAN2 (Serial1) Asynchronous: RS232 DB-50 Synchronous: V.24, V.35 and X.21 DTE: 1200-4096 k DCE: 1200-2048 k 300-115.2 k WAN port, namely, the S port, for connecting the WAN in the synchronous and asynchronous modes
Name
Function
Prompter
Exit command
[QuidwaySerial0]
[QuidwayAsync0]
[QuidwayAux0]
[QuidwayEthernet0]
IP address and subnet mask of port E0 in the local Ethernet network IP address and subnet mask of port S0 in the WAN Destination network segment, subnet mask and next hop IP address for the wide-used static route Encapsulated protocols for the WAN
Huawei Technologies Proprietary 26
II. Routes
The route table contains two types of routes:
Static routes. You can set the route in the route table manually. Static routes are commonly used in networking to realize access to the remote network. Dynamic routes. Dynamic routes in the route table are addressed by the bound dynamic routing protocols, such as OSPF, RIP, IGRP and BGP. With these protocols, the router can discover corresponding routes dynamically in the network. The route priority varies according to the corresponding protocol.
If as a DCE, it needs to provide clock for the peer-end DET. In this case, select DCEclk. If as a DTE, it receives clock from the peer-end DCE. For the synchronous equipment, the receiving and transmitting clocks are mutually independent. Therefore, you can select the receiving or transmitting clock of the DCE as the receiving clock of the DTE. It is the same case with the DTE transmitting clock. In this way, four combinations are available. That is, the clock at the DTE side has four choices, as shown in Table 1.1.
Table 1.1 Clock selection for the synchronous serial port at the DTE side Selection DTEclk1 Meaning TxClk = TxClk, RxClk = RxClk
Meaning TxClk = TxClk, RxClk = TxClk TxClk = RxClk, RxClk = TxClk TxClk = RxClk, RxClk = RxClk
In this table, TxClk is the transmitting clock and RxClk the receiving clock. The clock in front of = is the DTE-side clock, while that behind = is the DCE-side clock. In the partial E1/T1 networking, the router is a DTE, and Mercury 3600 is a DCE. Therefore, Mercury 3600 provides the clock for the router.
V. Instance
This section uses an instance to introduce the scheme planning and commissioning procedure.
Plan the IP address of port E0 in the local Ethernet network as 129.9.0.1 and the subnet mask as 255.255.0.0. Plan the IP address of port S0 in the WAN as 129.8.0.1 and the subnet mask as 255.255.0.0. Plan the destination network segment of the static route as 129.10.0.0, subnet mask as 255.255.0.0 and next hop IP address as 129.8.0.2. Plan the encapsulated protocol for the WAN as PPP. Plan the clock at the WAN port as DTEclk2.
3.5.4 Procedure
According to the planning in 3.5.3VInstance, configure Quidway 2501 as follows:
I. Configuring HyperTerminal
1) 2) Use the configuration cable delivered with Quidway 2501 to connect port CONSOLE on it and the serial port on the PC. Run the HyperTerminal program, and set up a connection. Use the serial port connection, and set the communications parameters as: 9600 bit/s, no parity check, one stop bit, flow control as Xon/Xoff, no FIFO buffer, and terminal type as VT100. 3) Switch on Quidway 2501, and HyperTerminal displays the self-check information about Quidway 2501. When the self-check is complete, the system prompts you to press Enter. 4) Press Enter, and the system enters the Quidway state.
This part describes how to use the command line to configure the router.
Note: The system prompts you to configure the router in the setup mode on the first boot. You can also execute the command setup to enter the setup mode, as follows: [Quidway] setup
The detail procedure for configuring Quidway 2501 is as follows: 1) Log on the router.
Switch on the router, and the system carries out the self-check. When this self-check is complete, the system enters the system view, namely, the Quidway state. 2) Execute the following command to check the router configuration data:
[Quidway] display current-config Or execute the short command display cur. The system displays the router configuration. 3) Set the system name as the prompter.
[Quidway] sysname 4) Set the IP address and subnet mask for the Ethernet port.
If the set IP address and mask do not meet the actual requirements, execute corresponding commands to modify them. For example, to modify the IP of port E0,
Huawei Technologies Proprietary 29
execute the following commands: [Quidway] interface e0 //Enter the environment for setting port E0. //Delete
[Quidway-Ethernet0] undo ip address xxx.xxx.xxx.xxx 255.xxx.xxx.xxx the IP address previously configured for this port.
[Quidway-Ethernet0] ip address 129.9.0.1 255.255.0.0 //Reset the IP address and mask for this port.
% Line protocol ip on interface Ethernet0, changed state to UP
If the set static route does not meet the actual requirements, execute the following corresponding commands to modify it: [Quidway] undo ip route-static ip-address (destination IP) mask (subnet mask) ip-
//Delete the previously set static route. 255.255.0.0 129.8.0.2 //Reset the static
Set the IP address and subnet mask for the WAN port. //WAN port. Define S0 or S1 according to the actual //Delete the
[Quidway-Serial0] undo ip address xxx.xxx.xxx.xxx 255.xxx.xxx.xxx IP address previously configured for this port.
[Quidway-Serial0] ip address 129.8.0.1 255.255.0.0 //Reset the IP address and mask for this port. [Quidway-Serial0] quit 7) //Go back to the prompter Quidway.
The WAN port on the Quidway 2501 router is encapsulated with the PPP protocol by default. To modify the encapsulated communications protocol, execute the following commands: [Quidway] interface s0 //Enter the configuration mode for the WAN port S0. //Encapsulate PPP.
The Quidway 2501 router works by default as a DTE in the network. It uses the clock in the DTEclk1 mode. To modify the clock mode, execute the following command: [Quidway] clock DTEclk2 9) //Set the clock mode to DTEclk2.
[Quidway] save
Now writing the running config to Flash Memory memory. Please wait for a while...... write the running config to Flash Memory memory successfully
The interface definition and static route configuration are complete by now. When the router is restarted, enter the system view, and check and modify the just configured data.
When the router configuration is complete at both sides of the network, execute the following command on any router to display the S0 status: [Quidway] display interface s0
Serial0 is up, line protocol is up physical layer is synchronous interface is DTE, clock is DTECLK1, cable type is V35 Encapsulation is PPP LCP opened, IPCP opened, IPXCP initial 5 minutes input rate 0.00 bytes/sec, 0.00 packets/sec 5 minutes output rate 1.19 bytes/sec, 0.06 packets/sec Input queue is 0/75/0 (current/max/drops)
Queueing strategy: FIFO Output Queue :(size/max/drops)0/75/0 6 packets input, 88 bytes, 0 no buffers
27 packets output, 466 bytes, 0 no buffers 0 input errors, 0 CRC, 0 frame errors 0 overrunners, 0 aborted sequences, 0 input no buffers DCD=UP DTR=UP DSR=UP RTS=UP CTS=UP
If the above information contains the following, it shows that the whole link layer is configured ready:
Serial0 is up, line protocol is up.. LCP opened, IPCP opened DTR=UP DSR=UP RTS=UP CTS=UP DCD=UP
2)
Execute ping to check whether the remote network is connected. [Quidway] ping xxx.xxx.xxx.xxx (IP of E0 on the peer-end router)
If the system displays the following information, it shows that this WAN port is not activated:
Serial0 is down
In this case, execute the following commands to activate this WAN port: [Quidway] interface serial 0 [Quidway-Serial0] undo shutdown If still failed, check the cable connection to make sure that all cables are connected correctly and tightly.
If you fail to ping the local S0 and the WAN port and E0 corresponding to the peerend router, it shows that the connection is not working. In this case, check and make sure that all cables are connected correctly and tightly. You can use the self-loop to verify whether the communications problem is caused by faulty links. Check further the router configuration, including the IP address, mask, static route, protocol encapsulated on the WAN port, the corresponding timeslot, and the extracted clock. Locate the problem, and make sure that you can ping the peerend LAN successfully.
Note: What is described in this section applies only to the common networking. For more information, refer to related technical documents about Quidway 3640.
III. Interfaces
Quidway 3640 provides up to four slots for network interfaces. You can configure up to four interface modules according to the actual need. This part describes the Ethernet module and WAN module used in the M2000 system network. There are two types of Ethernet modules:
1-port 10Base-T/100Base-TX Fast Ethernet interface module (1FE) 2-port 10Base-T/100Base-TX Fast Ethernet interface module (2FE)
The 1FE module provides one 10/100 Mbps Ethernet RJ-45 interface, while the 2FE module provides two. Ethernet ports on Quidway 3640 are numbered from Ethernet 0. For example, if you insert the 1FE module in slot 1 and the 2FE module in slot 2, the Ethernet port for slot 1 is numbered Ethernet 0, and those for slot 2 are numbered Ethernet 1 and Ethernet 2. There are four types of WAN modules:
1-port channelized cE1/PRI module (1E1) 2-port channelized cE1/PRI module (2E1) 4-port channelized cE1/PRI module (4E1) 2SA/4SA fast synchronous/asynchronous serial port module
Each cE1 interface is a Controller E1. The Controller E1 ports are numbered as follows:
The first Controller E1 port is numbered Controller E1 0. From slot 0, the Controller E1 ports are numbered increasingly by degrees. The first Controller E1 port on the module in the following slot is numbered as the number of the last Controller E1 port on the module in the current slot plus one.
On the same interface module, the Controller E1 ports are numbered the same as the numbers marked on the module panel.
For example, if you insert a 4E1 module in slot 1 and a 2E1 module in slot 3 on Quidway 3640, the four cE1/PRI ports on the module in slot 1 are numbered from Controller E1 0 to Controller E1 3, and the two on the module in slot 3 are numbered Controller E1 4 and Controller E1 5.
Different commands need to be executed on corresponding command views. Table 1.1 lists functional features of the common command views and also commands for entering each view.
Table 1.1 Command views of Quidway 3640 Name Function Prompter Enter command System view For setting system parameters [Router] You enter this view by logging on the router. View for the synchronou s serial port For setting parameters for the synchronous serial port View for the asynchrono us serial port For setting parameters for the asynchronou s serial port View for port AUX For setting parameters for port AUX [Router-Aux0] Type interface aux 0 on any view to enter this view. View for port AM For setting parameters for port AM [Router-AM0] Type interface am 0 on any view to enter this view. View for port Ethernet For setting parameters for port Ethernet View for port For setting [Router-E1-0] [Router-Ethernet0] Type interface ethernet 0 on any view to enter this view. Type Type quit to go back to the system view. Type quit to go back to the system view. Type quit to go back to the system view. Type quit [Router-Async0] Type interface async 0 on any view to enter this view. Type quit to go back to the system view. [Router-Serial0] Type interface serial 0 on any view to enter this view. Exit command You exit this view by logging off the router. Type quit to go back to the system view.
Name
Function
Prompter
Enter command
CE1
the timeslot binding mode and physical layer parameters for port CE1
For setting the timeslot binding mode and physical layer parameters for port CT1
[Router-T1-0]
IP address and subnet mask of port E0 in the local Ethernet network IP address and subnet mask of port S0 in the WAN Destination network segment, subnet mask and next hop IP address for the wide-used static route Type of the WAN port, and the communications protocol to bind to interfaces, such as X.25, Frame Relay and HDLC Network protocol to use, such as AppleTalk, IP and IPX (usually IP selected)
When working in the E1 mode, it is an interface with a bandwidth as 2 Mbit/s and with no timeslot division. It has the same logical characteristics as the synchronous serial port. It supports link layer protocols such as PPP, Frame Relay, LAPB and X.25, and supports network protocols such as IP and IPX.
These timeslots are numbered from 0 to 31. When working as a cE1 interface, it divides randomly all timeslots except timeslot 0 into several groups. The timeslots in each group are bound and work as a channel-group interface. This bound interface supports link layer protocols such as PPP, Frame Relay, LAPB and X.25, and supports network protocols such as IP and IPX.
Note: In the partial E1/T1 networking, Quidway 3640 works as the router in the Network Management Center (NMC). It communicates directly with various NE-side routers through port E1. The communication process is as this: Mercury 3600, a timeslot cross equipment, aggregates NMS information of various managed NEs to one E1 port, and then transmits the aggregated information to port E1 on the router. Therefore, it is important to configure port E1 on Quidway 3640.
III. Instance
This part uses an instance to introduce the scheme planning and commissioning procedure.
Plan the IP address of the Ethernet port in the local Ethernet network as 10.11.100.1 and the subnet mask as 255.255.255.0. Plan the IP address of the WAN port as 133.133.133.1 and the subnet mask as 255.255.255.252. Plan the destination network segment of the static route as 10.11.1.0, subnet mask as 255.255.255.0 and next hop IP address as 133.133.133.2.
3.6.4 Procedure
According to the planning in 3.6.3IIIInstance, configure Quidway 3640 as follows:
Huawei Technologies Proprietary 36
I. Configuring HyperTerminaling
1) 2) Use the configuration cable delivered with Quidway 3640 to connect port CONSOLE on it and the serial port on the PC. Run the HyperTerminal program, and set up a connection. Use the serial port connection, and set the communications parameters as: 9600 bit/s, no parity check, one stop bit, flow control as Xon/Xoff, no FIFO buffer, and terminal type as VT100. 3) Switch on Quidway 3640, and HyperTerminal displays the self-check information about Quidway 3640. When the self-check is complete, the system prompts you to press Enter. 4) Press Enter, and the system enters the Router state.
This part describes how to use the command line to configure the router.
Note: The system prompts you to configure the router in the setup mode on the first boot. You can also execute the command setup to enter the setup mode, as follows: [Quidway] setup
The detail procedure for configuring Quidway 3640 is as follows: 1) Log on the router.
Switch on the router, and the system carries out the self-check. When this self-check is complete, the system enters the system view, namely, the Router state. 2) Set the system name as the prompter.
[Quidway] sysname 3) Set the IP address and subnet mask for the Ethernet port. //Enter the mode for configuring the specified
[Router-Ethernet0] ip address 10.11.100.1 255.255.255.0 //Reset the IP address and mask for E0. 4) Set the WAN port cE1/PRI. //Set the E1 port with the number as 0.
[Router] controller e1 0
[Router-E1-0] code ami | hdb3 //Set the line code format to AMI or HDB3. The system default setting is HDB3. [Router-E1-0] using e1|ce1 //The cE1/PRI port works in the E1 or cE1/PRI mode. The system default setting is the cE1 mode. [Router-E1-0] frame-format crc4 // Set the frame check mode of the cE1/PRI port to the 4-byte CRC. You can also set not to use the CRC.
Note: Set whether to use the CRC according to the specific network communications requirements. If Mercury 3600 that communicates with the router uses the CRC, set the CRC for the router; otherwise, not.
[Router-E1-0] channel-set 1 timeslot-list 1-4 //Define that channel set 1 binds timeslots 1, 2, 3 and 4.
Note: Timeslot 0 is usually not involved in the channel definition. It is used for synchronizing the clock during the line communications. Therefore, the timeslot binding starts from timeslot 1.
5)
[Router-E1-0] interface serial 0:1 [Router-Serial0:1] ip address 133.133.133.1 255.255.255.252 [Router-Serial0:1] link-protocol ppp [Router-Serial0:1] quit 6) Set the static route.
If the set static route does not meet the actual requirements, execute the following corresponding commands to modify it: [Router] ip route-static 10.11.1.0 255.255.255.0 133.133.133.2 route. 7) Save the setting and check the configuration. //Reset the static
Press Ctrl+Z to go back to the prompter Router. [Router] save //Save the configuration into the flash memory.
When the router configuration is complete at both sides of the network, execute the following command on any router to display the S0 status: [Router] display interface serial 0 The displayed port information includes:
Physical status of the port and protocol status Physical characteristics of the port, such as synchronous/asynchronous, DTE/DCE, selected clock, baud rate and external cables IP address of the port Link layer protocols encapsulated on the port and their running status and statistics Input/output message statistics. Check the remote network.
2)
Execute ping to check whether the remote network is connected. [Router] ping xxx.xxx.xxx.xxx (IP of E0 on the peer-end router) If you can ping the port, it shows that the configuration is correct and the network is usable. Otherwise, check the configuration and the network connection. You can use the self-loop to verify whether the communications problem is caused by faulty links. Check further the router configuration, including the IP address, mask, static route, protocol encapsulated on the WAN port, the corresponding timeslot, and the extracted clock. Locate the problem, and make sure that you can ping the peerend LAN successfully.
For example, the mediation installation package for the M2000V200R002C02B006 UMG is iManagerM2000_UMG_MATCH_ENG_V200R002C02B006.tar. 3) Check the running status of M2000 services.
Log on the M2000 server as root, and then execute the following command: # svc_adm -cmd status In normal circumstances, the information returned by the system contains [Not Runing : 0 ]. This shows that all the M2000 services are started. 4) Check the running status of the high availability (HA) system, if any.
Log on any of the two M2000 servers as root, and then execute the following command: # scstat In normal circumstances, the system returns the following information:
Cluster Nodes: Both two nodes are online. Cluster Transport Paths: There are two transport paths, and both are online. Quorum Votes by Node: Both nodes are online.
Huawei Technologies Proprietary 1
Quorum Votes by Device: The device is online. Device Group Servers: The active server configured by the device group ossdg is the active node, and the standby server is the standby node. Device Group Status: The device group ossdg is online. Resource Groups and Resources: The resource group oss_rg contains resources such as osssvr, ossdg_rs, sybase_rs and ossapp_rs. Resource Groups: oss_rg is online on the active node and offline on the standby node. Resource: All resources are online on the active node and offline on the standby node. If the system is installed with two tape drives, rmt/1 and rmt/2 are displayed, both in offline status.
Step 9
Action Check the LMT interface between the M2000 and this NE.
Log in to the M2000 server as user root, and then execute the following command: # mkdir -p /export/home/mediation 2) Upload this installation package in the bin mode to /export/home/mediation through FTP. For example, copy the mediation software installation package for the UMG iManagerM2000_UMG_MATCH_ENG_V200R002C02B006.tar to the M2000 client, and then upload it in the bin mode to /export/home/mediation on the M2000 server through FTP.
# stop_svc 3) Check over the M2000 services to make sure that all are stopped.
# svc_ps If there is output for this command, execute kill_svc to stop all the services forcibly. Repeat these operations until there is no output after you execute svc_ps. 4) Stop Collector.
# /opt/OMC/bin/stop_collector
II. In HA System
Log on the active node as root, and then execute the following command: 1) Set the work environment for the M2000 system.
# scswitch -n -j ossapp_rs 3) Check over the M2000 services to make sure that all are stopped.
# svc_ps If there is output for this command, execute kill_svc to stop all the services forcibly. Repeat these operations until there is no output after you execute svc_ps. 4) Stop Collector.
# /opt/OMC/bin/stop_collector
# mkdir -p /export/home/UMGENGC02B006 2) Check the database backup service to make sure that it is started.
# ps -ef | grep backupserver | grep -v grep Execute this command. If there is output, it shows that the backup server is started. In this case, you can back up the database. If not, execute the following commands to log in as dbuser, start the backup server, log out as dbuser, and then log in as root. # su - dbuser bash-2.03$ cd /opt/sybase/ASE-12_0/install/ bash-2.03$ nohup ./startserver -f ./RUN_SYB_back > /dev/null bash-2.03$ su - root 3) Back up the six databases: omcdb, sysmdb, fmdb, pmdb, itfndb and inrptdb2.
# mkdir -p /export/home/MGWENGC02B006/dbbackup # chmod -Rf a+rw /export/home/MGWENGC02B006/dbbackup # isql -SSYB -Usa -P<password of sa> 1>dump 2>go 1>dump 2>go 1>dump 2>go 1>dump 2>go 1>dump 2>go 1>dump
to
to
to
to
to
to
2>go 1>exit The database backup in the single server system is complete.
II. In HA System
Log on the active node as root, and then carry out the following operations: 1) Create the backup directory.
# mkdir -p /export/home/UMGENGC02B006 2)
# scstat -g In normal circumstances, sybase_rs is online. (sybase_rs is the resource name of Sybase. It varies according to the actual situation.) 3) Check the backup server to make sure that it is started.
# ps -ef | grep backupserver | grep -v grep Execute this command. If there is output, it shows that the backup server is started. In this case, you can back up the database. If not, please contact Huawei Technologies Co., Ltd. (Huawei). 4) Back up the six databases: omcdb, sysmdb, fmdb, pmdb, itfndb and inrptdb2.
# mkdir -p /export/home/MGWENGC02B006/dbbackup # chmod -Rf a+rw /export/home/MGWENGC02B006/dbbackup # isql -SSYB -Usa -P<password of sa> 1>dump 2>go 1>dump 2>go 1>dump 2>go 1>dump 2>go 1>dump
to
to
to
to
to
2>go 1>dump 2>go 1>exit The database backup in the HA system is complete.
to
# cd /export/home/mediation # tar xf iManagerM2000_UMG_MATCH_ENG_V200R002C02B006.tar The system generates a directory named install mediation automatically. 3) Install the mediation software.
# cd /export/home/mediation/installmediation # ./install.sh 2>&1 | tee -a /var/med_install.sh The following information is displayed for you to confirm:
the Install NE Type is : MGWNE the Install NE Version is : UMG8900V200R003C01B053 the Install Match Version is : iManagerM2000_UMG_MATCH_ENG_V200R002C02B006 Environment variable M2K_ROOT is : /opt/OMC
Enter y to start the installation, and enter any other character to exit the installation. 4) If this version of mediation software is installed for the first time, the installer completes the whole installation. If already installed, the installer prompts you to decide whether to overwrite the existing version.
Huawei Technologies Proprietary 7
The MGWNE iManagerM2000_UMG_MATCH_ENG_V200R002C02B006 mediation has been created! Do you want to overwrite it? [y/n]
In this case, enter "y" to uninstall the existing version, and then reinstall this version of mediation software. Enter any other character to exit the installation. Note to check words such as "error" or fail in the output returned by the system. If displayed, please contact Huawei. Logs for the installation process are recorded into the file /var/med_install.sh.
Take the MGW for example. # displayVersion -ne MGW // Check the output for the following information: <MGW> Match Version : iManagerM2000_UMG_MATCH_ENG_V200R002C02B006 NE Version : UMG8900V200R003C01B053
If it is not contained in the output, you need to reinstall the mediation software. Check the following path to make sure that it is the correct installation for the M2000: The environment variable M2K_ROOT is /opt/OMC. If the installation path is correct, contact Huawei if you still fail to install the mediation software.
# start_svc You can open a Telnet window to log on the server when the M2000 services are starting. To monitor the startup process, execute the following command: # tail -f /opt/OMC/startsvc.log When all the M2000 services are started about 10 minutes later, close this Telnet window. 2) Start Collector.
# /opt/OMC/bin/start_collector
II. In HA System
Log on the active node as root, and then carry out the following operations: 1) Start M2000 services.
# /opt/OMC/bin/start_collector
4.5 Creating an NE
4.5.1 Creating a UMTS NE
I. Job Introduction
Create a UMTS NE in the topology tree on the M2000 client. After this NE is created, the M2000 generates management objects for this NE. Through the automatic synchronization with the NE, the M2000 obtains the NE configuration, and then saves it into the M2000 database. In addition, maintenance channels are established between the M2000 and the UMTS NE to enable the M2000 server to manage the UMTS NE.
II. Prerequisites
Before you create the UMTS NE, make sure that:
The connection between the M2000 system and the UMTS NE is normal. M2000 services are running normally. The mediation software for this UMTS NE is installed successfully on the server.
III. Procedure
All UMTS NEs except Node B are created on the M2000 client in the same procedure. Take the RNC creation for example, and the procedure is as follow: 1) Select the subnet.
Plan the location of the RNC in the topology tree and the subnet it belongs to.
If the subnet with this NE does not exist in the topology tree, you need to create this subnet. Right click on the topology tree, and then select Create Physical Subnet. In the displayed dialog box, enter the subnet name, and then choose this subnet in the topology tree.
If the subnet with this NE already exists, choose this subnet in the topology tree. Create the RNC.
2)
Right click on the topology tree, and select Create NE on the displayed menu. In the displayed dialog box, select Access Network Series as the category and RNC as the NE type, and then click Next. Enter the name and IP address of this NE, and then click Finish. Figure 2.1 shows the process for creating the RNC.
After you create the NE, a corresponding icon is displayed on the topology tree for this NE. If the connection between this NE and the M2000 works normally, the M2000 synchronizes data with this NE to obtain the NE configuration. The synchronization status is displayed in the topology tree. 4) Set the file server.
Choose Software -> File Server Setting, and then select the NE type in the
navigation tree in the left part of the displayed window. In this example, select RNC. In the right part window, select the created NE and the name of its file server. You can select the OMC or the RNC itself as the file server for the created RNC NE. (OMC refers to the M2000.) If there is a firewall between the RNC and the OMC, you must select OMC as the file server. It is the same case with other NEs. By now, the creation of the UMTS NE is complete. The M2000 can obtain automatically the default performance data, alarm and log information of this NE.
II. Prerequisites
Before you create a GSM NE, make sure that:
The connection between the M2000 system and NEs is normal. M2000 services are running normally. The mediation software for the NE is installed successfully on the server.
III. Procedure
All GMS NEs are created on the M2000 client in the same procedure. Take the BSC creation for example, the procedure is as follows: 1) Select the subnet.
Plan the location of the BSC in the topology tree and the subnet it belongs to.
If the subnet with this NE does not exist in the topology tree, you need to create this subnet. Right click on the topology tree, and then select Create Physical Subnet. In the displayed dialog box, enter the subnet name, and then choose this subnet in the topology tree.
If the subnet with this NE already exists, choose this subnet in the topology tree. Create the BSC.
2)
Right click on the topology tree, and select Create NE on the displayed menu. In the displayed dialog box, select Access Network Series as the category and BSC as the NE type, and then click Next. Enter the name and IP address of this NE, and then click Finish. Figure 2.1 shows the process for creating the BSC.
After you create the NE, a corresponding icon is displayed on the topology tree for this NE. If the connection between this NE and the M2000 works normally, the M2000 synchronizes data with this NE to obtain the NE configuration. Meanwhile, the synchronization status is displayed in the topology tree. By now, the creation of the GSM NE is complete. The M2000 can obtain automatically the default performance data, alarm and log information of this NE.
II. Prerequisites
Before you create the CDMA NE, make sure that:
The connection between the M2000 system and NEs is normal. M2000 services are running normally. The mediation software for the NE is installed successfully on the server.
III. Procedure
All CDMA NEs are created on the M2000 client in the same procedure. Take the
MGW creation for example, and the procedure is as follows: 1) Select the subnet.
Plan the location of the MGW in the topology tree and the subnet it belongs to.
If the subnet with this NE does not exist in the topology tree, you need to create this subnet. Right click on the topology tree, and then select Create Physical Subnet. In the displayed dialog box, enter the subnet name, and then choose this subnet in the topology tree.
If the subnet with this NE already exists, choose this subnet in the topology tree. Create the MGW.
2)
Right click on the topology tree, and select Create NE on the displayed menu. In the displayed dialog box, select Core Network Series as the category and MGW as the NE type, and then click Next. Enter the name and IP address of this NE, and then click Finish. Figure 2.1 shows the process for creating the BSC.
After you create the NE, a corresponding icon is displayed on the topology tree for this NE. If the connection between this NE and the M2000 works normally, the M2000 synchronizes data with this NE to obtain the NE configuration. Meanwhile, the synchronization status is displayed in the topology tree. By now, the creation of the CDMA NE is complete. The M2000 can obtain automatically the default performance data, alarm and log information of this NE.
II. Prerequisites
Before you create an IP device, make sure that:
The connection between the M2000 system and the IP device is normal. M2000 services are running normally.
III. Procedure
1) Select the subnet.
Plan the location of the IP device in the topology tree and the subnet it belongs to.
If the subnet with this NE does not exist in the topology tree, you need to create this subnet. Right click on the topology tree, and then select Create Physical Subnet. In the displayed dialog box, enter the subnet name, and then choose this subnet in the topology tree.
If the subnet with this NE already exists, choose this subnet in the topology tree. Create the IP device.
2)
Right click on the topology tree, and select Create NE on the displayed menu. In the displayed dialog box, select IP Device Series as the category and IP Device as the NE type, and then click Next. Enter the name and IP address of this NE, and then click Finish. By now, the creation of the IP device is complete. The M2000 can obtain automatically alarm information of this IP device.
II. Prerequisites
Before you create the RAN, make sure that:
The connection between the M2000 system and NEs in the UMTS RAN is normal. M2000 services are running normally. The mediation software for each NE is installed successfully on the server. Physical channels are set up between the RNC and NodeBs, and the interface data is configured.
III. Procedure
An RAN contains an RNC and NodeBs in this RNC. Create the RNC first, and then each NodeB. Refer to 4.5.1IIIProcedure to create the RNC. For creating the NodeBs, you can create them one by one in the same way as the RNC; or you can create them all at once, as follows: 1) Select the RNC.
Select the RNC with all the NodeBs in the topology tree. 2) Search automatically and create the NodeBs.
Right click the RNC node and select Search. The system automatically searches all NodeBs in this RNC, creates topological objects for them in the topology tree, and then synchronizes data with these NodeBs. 3) Set the file server.
Choose Software -> File Server Setting. Select any NodeB node in the navigation tree in the left part of the displayed window, and the created NodeB NEs are displayed in the right part window. Select the file server for each of them. You can select the OMC or the corresponding RNC as the file server for the created NodeB NE. (The OMC refers to the M2000.) If there is a firewall between the RNC and the OMC, you must select the OMC as the file server. By now, the creation of the UMTS RAN is complete. The M2000 can obtain automatically the default performance data, alarm and log information of this RAN.
up maintenance channels with the NE and have it managed. This applies only to the UMTS NEs, but not the GSM or CDMA NEs.
II. Prerequisites
Before you create NEs in batches, make sure that:
The connection between the M2000 system and NEs is normal. M2000 services are running normally. The mediation software for each NE is installed successfully on the server.
III. Procedure
Create multiple NEs in batches on the M2000 client as follows: 1) Edit the file for creating NEs in batches.
Create a CSV template for creating NEs in batches. Open the template, enter the NE information, and then save the file. For specifications on the NE template, see M2000 Operation Manual. 2) Select the subnet.
Plan the location of these NEs in the topology tree and the subnets they belong to.
If the subnet with this NE does not exist in the topology tree, you need to create this subnet. Right click on the topology tree, and then select Create Physical Subnet. In the displayed dialog box, enter the subnet name, and then choose this subnet in the topology tree.
If the subnet with this NE already exists, choose this subnet in the topology tree. Import the file for creating NEs in batches.
3)
Right click on the topology tree and select Create Physical NEs in batches. In the displayed dialog box, select a CSV file containing information of NEs to be created in batches. Click OK, and the system creates automatically all NEs defined in the file. By now, the creation of multiple NEs in batches is complete. The M2000 can obtain automatically the default performance data, alarm and log information of these NEs.
II. Prerequisites
Before you check this function, make sure that:
The NE is successfully created in the M2000 system. The NE in the topology tree is connected with the M2000 system.
III. Procedure
Log on the M2000 client and the NE LMT, and then carry out the following operations: 1) Open the M2000 alarm browser.
On the M2000 client, choose Fault -> Current Fault Alarm Browser to display Current Fault Alarm Browse 1. 2) View the current alarm.
Select the NE and click Apply, and the system displays the alarm information in a dialog box as shown in Figure 2.1.
Pull out a trunk cable, and the LMT for this NE displays the trunk alarm. 4) Check to make sure that you can view this alarm on the M2000.
Open the window for displaying the alarm information. In normal circumstances, it shows the alarm information on this NE.
II. Prerequisites
Before you check this function, make sure that:
The NE is successfully created in the M2000 system. The NE in the topology tree is connected with the M2000 system.
III. Procedure
Log on the M2000 client as admin, and then carry out the following operations: 1) Open the M2000 performance query window.
On the M2000 client, choose Performance -> Query Result to display Query Result. 2) Set query conditions.
Click New Query to display Query. In the navigation tree on the left, select the NE and the involved measurement sets; in the right part window, select objects (limited to only available objects in the system), counters and measurement period. Click Query. The queried results are shown in Figure 2.1
Figure 2.1 Querying performance information 3) Check to make sure that you can view the performance data on the M2000 client. In normal circumstances, the system displays the performance data in Query Result after you define the measurement period.
II. Prerequisites
Before you check this function, make sure that:
The NE is successfully created in the M2000 system. The NE in the topology tree is connected with the M2000 system.
III. Procedure
Log on the M2000 client as admin, and then carry out the following operations:
Huawei Technologies Proprietary 19
1)
On the M2000 client, choose Tools -> System Backup -> Manual Backup to display Manual Backup, as shown in Figure 1.1.
Figure 1.1 Manual backup 2) Select the NE you want to back up.
Select NE, and select the accessed NE, and then click Start. In the displayed dialog box, click Yes, and the system displays Backup Browser. 3) Observe the backup progress.
The lower part of Backup Browser shows the backup progress. In normal circumstances, the progress changes from 0% to 100%. 4) Check to make sure that the M2000 backs up the NE data.
When the backup progress reaches 100%, select Backup List. In normal circumstances, you can see data files of the backed-up NE.
At present, only logs of UMTS NEs can be uploaded to the M2000. Logs of GSM and CDMA NEs cannot be uploaded.
II. Prerequisites
Before you check this information, make sure that:
The NE is successfully created in the M2000 system. The NE in the topology tree is connected with the M2000 system.
III. Procedure
Log on the M2000 client as admin, and then carry out the following operations: 1) Synchronize NE logs.
On the M2000 client, right click this NE in the topology tree, and then select Synchronize NE Log. 2) Open Software Browser.
On the M2000 client, choose Software -> Browser to display Software Bowser. 3) Observe the upload progress.
The lower part of Software Browser shows the progress for uploading the NE logs. In normal circumstances, the progress changes from 0% to 100%. 4) Check the NE logs on the M2000 client.
When the progress reaches 100%, choose System -> Log Management -> Log Query and Statistic on the M2000 client. In the displayed Log Management, choose NE Log under Log Query in the navigation tree, and select the NE in Filter Condition, and then click Query, as shown in Figure 4.1
Figure 4.1 Querying NE logs In normal circumstances, logs of this NE are displayed in the lower part of Log Management.
II. Prerequisites
Before you add an NE user, make sure that:
The NE is successfully created in the M2000 system. The NE in the topology tree is connected with the M2000 system.
III. Procedure
Log on the M2000 client as admin, and then carry out the following operations: 1) Open Security Management.
On the M2000 client, choose System -> Security Management to display Security Management. 2) Create an NE user.
Choose the NE in the navigation tree on the left. Right click this NE, and then select
Huawei Technologies Proprietary 22
Add NE User to display Add NE User. Select the user account from the list, and then click OK. The system binds this M2000 user account to this NE, so that this user becomes the NE user. 3) Bind command groups.
In the navigation tree on the left, right click the created NE user under the node User, and select Bind NE to display Bind User to NE. Select command groups from the list on the right and then click OK, so that this user can execute commands in these command groups, as shown in Figure 3.1.
Figure 3.1 Binding NE user to command groups By now, an NE user is added successfully. Use this user account to log in, and check to make sure that you can execute MML commands and start the LMT of this NE.
II. Prerequisites
Before you check this function, make sure that:
The NE is successfully created in the M2000 system. The NE in the topology tree is connected with the M2000 system. Users are added for this NE.
III. Procedure
Log on the M2000 client as the user bound to this NE, and then carry out the following operations: 1) Open MML Command.
Choose Configuration -> MML Command to display MML Command, as shown in Figure 1.1.
Figure 1.1 MML command 2) Obtain information about MML commands for this NE.
In the navigation tree in the upper part window, select the NE, and the system obtains MML command file automatically for this NE. 3) Execute MML commands.
In the lower part window in Figure 3.1, enter the MML command, and the system displays the returned information in the upper part window. For example, enter LST EMS for RNC NEs, and the system displays information about the M2000 operator.
Huawei Technologies Proprietary 24
Figure 3.1 Responding to MML command In normal circumstances, the NE responds to the delivered MML command.
II. Prerequisites
Before you check this function, make sure that:
The NE is successfully created in the M2000 system. The NE in the topology tree is connected with the M2000 system. Users are added for this NE. The LMT software of this NE is installed on the PC, and this LMT version matches the NE version.
III. Procedure
Log on the M2000 client as the user bound to this NE, and then carry out the following operations:
1)
In the topology tree, right click the NE and select Maintenance Client to display the local maintenance system of this NE.
Note:
For the non-GSM NE, the LMT provides only one operation menu, namely, [Maintenance]. For the GSM NE, the LMT provides multiple operation menus, such as [Traffic Statistics], [Data Management]. In addition, the LMT provides different operation menus for different GSM NEs.
2)
Log on the LMT as the NE user. In normal circumstances, you can start and log on the NE LMT on the M2000 client automatically as the NE user. No extra username or password is necessary.
Figure 1.1 Procedure for commissioning Alarm-Notification-over-BP/Telephone Table 1.1 describes this procedure in detail.
Table 1.1 Description of the procedure for commissioning Alarm-Notification-overBP/Telephone No. 1 Install a wired modem. Install an internal wired modem. Step Install an external wired modem. Reference 5.3.2Installing External Wired Modem 5.3.3Installing Internal Wired Modem Description You can install the modem on the server or the client. The latter is recommended. The M2000 system needs only one modem for AlarmNotification-over BP/Telephone. 2 Commission the modem. Commission the server side modem. Commission the client side modem. 3 Configure related parameters. 5.3.4Commissioni ng Server Side Modem 5.3.5Commissioni ng Client Side Modem 5.3.6Configuring Parameters for AlarmNotification-overBP/Telephone 4 Check this function. 5.3.7Checking AlarmNotification-overBP/Telephone The server and the client use different operating systems. Accordingly, the procedure for commissioning the modem varies. Configure parameters for this function on the client.
Serial ports A and B on the Sun server refer to the same physical serial port. Make sure not to connect two devices on these two ports at the same time. For example, avoid connecting wired and wireless modems at the same time.
Before you install any hardware, make sure to shut down the M2000 client. Connect the modem on an unused serial port. One serial port may be used by the alarm box. To view the serial port used by the alarm box, check the value of PortName in the file <Installation directory of M2000 client>\style\defaultstyle\conf\alarmclient\alarmboxconfig.xml . <PARA name="PortName" value="COM1" connected on serial port COM1. For example, /> shows that the alarm box is
The serial port cable used for installing the modem has the DB-25 connectors at both ends. One end connects the modem, and the other connects the serial port on the M2000 server or client.
Note: If the serial port on the M2000 server or client is a female or DB-9 connector, it does not match the serial port cable of the modem. In this case, use a convertor.
2)
Use the DC power cable delivered with the modem. For details about connecting the power cable, see the Specifications delivered with the modem. 3) Connect the telephone line.
Connect the telephone line to port Line on the modem. For details, see the Specifications delivered with the modem. 4) Install the modem driver.
See the Specifications delivered with the modem to install the modem driver.
Install it as follows: 1) 2) 3) Switch off the PC. Open the PC chassis. Insert the modem into the PCI slot.
Choose an available PCI slot and open the cover over it. Insert the modem into the slot, and make sure that the gilded joint part of the modem is pressed tightly into the PCI slot. Close the cover to fix the modem in the slot. 4) Connect the telephone line.
Connect the telephone line to port Line on the modem. For details, see the Specifications delivered with the modem. 5) 6) Close the PC chassis. Install the modem driver.
See the Specifications delivered with the modem to install the modem driver.
Execute tip -9600 /dev/term/a to enable the serial port and set the baud rate.
connected
In this command, 9600 is the baud rate, and /dev/term/a stands for serial port A. 4) Check to make sure that the modem works normally.
If the system returns OK, it shows that the modem is connected properly. 5) Try a number to test the dialing.
If the system returns OK, it shows that the dialing works normally. 6) Stop the dialing.
7)
Figure 4.1 Setting up a connection 5) Select the serial port for connection. For example, select COM1, as shown in Figure 5.1, and then click OK.
Figure 5.1 Selecting a serial port 6) Set attributes of the serial port according to Figure 6.1, and then click OK.
Figure 6.1 Setting serial port attributes 7) In Figure 7.1, enter the command at for commissioning the dialing.
Huawei Technologies Proprietary 7
If the system returns OK, it shows that the modem is connected properly. 8)
OK
If the system returns OK, it shows that the dialing works normally. 9)
OK
Note: After you install the modem on the client, log on the client as admin or a user that has the authority to set the remote alarm notification, and keep this client running. The alarm notification is deactivated if you shut down the client or log on the client as any other user account. Make sure that the parameter RemoteNotifyEventProcessor in the file <M2000 installation directory>\style\defaultstyle\conf\alarmclient\loadedcell.xml is not commented.
2) 3)
Choose Fault -> Fault Service Settings. In Remote Notify, select types of alarms to send, enter the BP or telephone number, and then click Setting. In the displayed Remote notify detail settings, select Phone pager. Select Activate, and enter parameters such as Serial port and Send point. Click Set.
Note: If you select Send by client as Send point, make sure to select Current client can be used for phone or pager on only one client. Otherwise, the same alarm notification may be sent many times.
4)
Enter the telephone number behind Test phoneNo or pagerNo, such as 862187654321, and then click Test. In the displayed Test, the M2000 drives the wired modem to dial this number. If everything is normal, the system prompts that the dialing is successful. Otherwise, the system prompts a failure message. In this case, check the configuration.
5) 6)
Click Close to close Remote notify detail settings. In Remote Notify, use Add to add a user information record for the remote alarm notification.
Monitor Configurations. 4) Modify the CPU and memory used rate. For example, set both the CPU and memory used rate to 2. The system generates an alarm when the CPU and memory used rate exceeds this value. Wait until the alarm board prompts the alarm. In normal cases, the phone rings or the pager beeps with three ringing tones for the system alarm. It displays the calling number if it subscribes to the Caller ID Display (CID) function. When the test is complete, restore the settings. If error occurs, check and make sure that the modem works normally, that parameters are configured correctly, and that the service RemoteNotifyService is running on the server.
Figure 1.1 Procedure for commissioning Alarm-Notification-by-Short-Messages Table 1.1 describes this procedure in detail.
Table 1.1 Description of the procedure for commissioning Alarm-Notification-byShort-Messages No. 1 Step Install the wireless modem. Reference 5.4.2Installing Wireless Modem Description You can install the modem on the server or the client. The latter is recommended. The M2000 system needs only one modem for AlarmNotification-over BP/Telephone. 2 Commissio n the modem. Commission the server side modem. Commission the client side modem. 3 Configure related parameters. 5.3.4Commissionin g Server Side Modem 5.3.5Commissionin g Client Side Modem 5.4.5Configuring Parameters for Alarm-Notificationby-Short-Messages 4 Check this function. 5.4.6Checking Alarm-Notificationby-Short-Messages The server and the client use different operating systems. Accordingly, the procedure for commissioning the modem varies. Configure parameters for this function on the client.
Serial ports A and B on the Sun server refer to the same physical serial port. Make sure not to connect two devices on these two ports at the same time. For example, avoid connecting wired and wireless modems at the same time.
Huawei Technologies Proprietary 11
Before you install any hardware, make sure to shut down the M2000 client. Specify the serial port used by the alarm box, if connected to the M2000 client. Make sure to connect the modem on an unused serial port. To view the serial port used by the alarm box, check the value of PortName in the file <Installation <PARA name="PortName" directory value="COM1" of For M2000 example, client>\style\defaultstyle\conf\alarmclient\alarmboxconfig.xml . connected on serial port COM1.
Install the subscriber identity module (SIM) card according to the operation guide of the wireless modem. 2) Disable the PIN check function of the SIM card.
Execute tip to deliver at to the SIM card to disable the personal identity number (PIN) check function of the SIM card. Suppose that the PIN in the SIM card is 1234. Execute the following two functions:
AT+CPIN=1234 AT+CLCK="SC",0,1234
Execute the first command to submit the PIN to the SIM card for check. Execute the second command to disable the PIN check function of the SIM card. If the SIM card returns error after you execute the second command, wait about one minute, and then execute it again.
Note: You can also insert the SIM card into a cell phone, and use the PIN setting in the cell phone to disable the PIN check. The setting interface varies according to the cell phone type. For details, see the instructions delivered with the cell phone.
3)
One end of the serial port cable used for installing the modem is a DB-9 male connector, and is connected to the modem. The other end is a DB-9 female connector, and is connected to the serial port on the M2000 client.
Note: If the serial port on the M2000 client is a female or DB-25 connector, it does not match the serial port cable of the modem. In this case, use a convertor.
4)
Use the DC power cable delivered with the modem. For details about connecting the power cable, see the Specifications delivered with the modem. 5) Install the modem driver.
See the Specifications delivered with the modem to install the modem driver.
Note: After you install the modem on the client, log on the client as admin or a user account authorized with the authority for setting the alarm notification, and keep this client running. The alarm notification is deactivated if you shut down the client or log on the client as any other user account.
Make sure that the parameter RemoteNotifyEventProcessor in the file <M2000 installation directory>\style\defaultstyle\conf\alarmclient\loadedcell.xml is not commented.
2)
Choose Fault -> Fault Service Settings. In Remote Notify, select types of alarms to send, enter the cell phone number for receiving the short message, and then click Setting.
3)
In the displayed Remote notify detail settings, select SMS. Select Activate, and enter parameters such as Serial port and Send point. Click Set.
Note: If you select Send by client as Send point, make sure to select Current client can be used to send SMS on only one client. Otherwise, the same alarm notification may be sent many times.
4)
In the entry box behind SMS Center NO, enter a cell phone number with the country code; for example, 8613987654321. Click Test to check whether the number is set correctly. If all settings are correct, the system prompts The operation is successful, and a short message This is a test is sent to the set cell phone.
5) 6)
Click Close to close Remote notify detail settings. In Remote Notify, use Add to add a complete user information record for the remote alarm notification.
In normal circumstances, the cell phone receives a SMS after a short while. The period of time from the SMS sending to the receiving depends on the mobile network. The received SMS is in the following format:
+++ MSC id=11 15:42:06 minor restored power system ---
When the test is complete, restore the settings. If error occurs, check and make sure that the modem works normally, parameters are configured correctly, and that the service RemoteNotifyService is running on the server.
Note: If you select Send by client as Send point, make sure that:
You log on the client as admin or a user account authorized with the authority for setting the alarm notification, and keep this client running. The alarm notification is deactivated if you shut down the client or log on the client as any other user account. The parameter RemoteNotifyEventProcessor in the file <M2000 installation directory>\style\defaultstyle\conf\alarmclient\loadedcell.xml commented. is not
2)
Choose Fault -> Fault Service Settings. In Remote Notify, select types of alarms to send, enter the Email address for receiving the notification, and then click Setting.
3)
In the displayed Remote notify detail settings, select Email. Select Activate, and enter parameters such as Hostname or IP of SMTP and Send point. Click Set.
Note: If you select Send by client as Send point, make sure to select Current client can be used to send Emails on only one client. Otherwise, the same alarm notification may be sent many times.
4)
In the entry box behind Address of receiver, enter an Email address for receiving the notification; for example, abc@def.com.cn. Click Test. An alarm notification Email is sent to this Email address, with alarm for test attached indicating that this is a test Email.
5) 6)
Click Close to close Remote notify detail settings. In Remote Notify, use Add to add a user information record for the remote alarm notification.
2004-10-01 12:30:00
Internet serial number: Equipment serial number: NE ID: NE type: Alarm ID: Alarm name: iMAP MSC 2
Alarm name used in the test productid=2 netype=0 alarmid=2 alarm for test
When the test is complete, restore the settings. If error occurs, check and make sure that the SMTP works normally, parameters are configured correctly, and that the service RemoteNotifyService is running on the server.
II. Fuse
For the AC 110 V power supply, choose the fuse with specifications as F, 2A, H, 250 V; for the AC 220 V power supply, choose the fuse with specifications as F, 1A, H, 250V.
II. DC Power
When the alarm box uses the DC -48 V power supply, change the connector previously connected to JT9 to JT6. Meanwhile, connect the DC -48 V power cable to JT3 on the power board inside the alarm box, as shown in Figure 1.1.
S2
ON OFF 1 2 3 4 5 6 7 8 ON OFF
S1
3 4
6 7 8
Adjust RP1 or RP2 counter clockwise with a Phillips screwdriver, namely, in the direction from 3 to 1 marked on the potentiometer.
Adjust RP1 or RP2 clockwise with a Phillips screwdriver, namely, in the direction from 1 to 3 marked on the potentiometer.
Create alarms of various severities on the alarm box, and check whether it gives corresponding audio/visual alarms. The indicator for an alarm severity remains on as long as there are unrestored and unacknowledged alarms of this severity. 2) Test the control of the M2000 over the alarm box.
The M2000 supports the following three operations on the alarm box:
Stopping the alarm sound: This operation equals to pressing the alarm acknowledgement button on the alarm box. Resetting the alarm box: This operation equals to pressing the reset button on the main board of the alarm box. Shutting down the alarm box: After this operation, the M2000 clears all alarm information stored in the alarm box and stops the sound and light. In addition, the M2000 does not send any alarm information to the alarm box. However, the communications connection between the M2000 and the alarm box still exists.
If abnormal results occur, check the serial port connection between the M2000 client and the alarm box.
Figure 1.1 Procedure for commissioning the dial-up connection Prepare all the required device cables, configure the dial-up server and client, and then check whether the dial-up connection works. After you set up a dial-up connection successfully, connect the terminal to the PSTN through the modem and telephone line. Configure this terminal as the dial-up client and make sure that this connection works. In this way, you can set up another dial-up connection.
Quantity
Use
Connect one modem to the M2000 client and the other to the dial-up server to have them accessing the PSTN. If the PCs are configured with a built-in modem, external modems are unnecessary. Refer to the attached manual of the modem to install the modem driver.
PSTN number
These two numbers are telephone numbers corresponding to the dial-up server and client in the PSTN.
In the Windows operating system, set the IP address as follows: 1) 2) 3) 4) 5) Choose Start -> Control Panel. Double-click Network Connections. Right-click on Local Area Connection, and select Properties to display Local Area Connection Properties. Select Internet Protocol (TCP/IP) and click Properties to display Internet Protocol (TCP/IP) Properties. Select Use the following IP address to display a dialog box as shown in Figure 5.1, and set IP address, Subnet mask and Default gateway. Make sure that the set IP is in the same network segment as the IP of the M2000 server, and then click OK.
Figure 1.1 New Connection Wizard 2) Click Next, and the system displays a dialog box as shown in Figure 2.1.
Figure 2.1 Network Connection Type 3) Select Accept Incoming Connections and click Next, and the system displays a dialog box as shown in Figure 3.1.
Huawei Technologies Proprietary 5
Figure 3.1 Selecting a connection device 4) Select modem, and then click Next to display a dialog box as shown in Figure 4.1.
Figure 4.1 Incoming Virtual Private Network (VPN) Connection 5) Select Do not allow virtual private connections (D), and then click Next to display a dialog box as shown in Figure 6.1.
Huawei Technologies Proprietary 6
6)
Select a user from the user list, and then click Next to display a dialog box as shown in Figure 6.3.
To add a user
Click Add to display a dialog box as shown in Figure 6.2. Set the user properties, and then click OK to display a dialog box as shown in Figure 6.3.
Figure 6.3 Network software 7) Select all components in the list, and then click Next to display a dialog box as shown in Figure 7.1.
Figure 7.1 New connection wizard complete 8) Enter a name for the connection, and then click Finish to complete configuring
Huawei Technologies Proprietary 8
Figure 2.1 Network Connection Type 3) Select Dial-up to private network, and then click Next to display a dialog box as shown in Figure 3.1.
Figure 3.1 Phone Number to Dial 4) Enter the telephone number to dial, namely, the number the dial-up server is connected to, and then click Next to display a dialog box as shown in Figure 4.1.
Figure 4.1 Connection Availability 5) Select Only for myself, and then click Next to display a dialog box as shown in
Huawei Technologies Proprietary 11
Figure 5.1.
Figure 5.1 New Connection Wizard complete 6) Enter a name for the connection, and then click Finish to complete configuring the dial-up client.
Figure 1.1 Setting dial-up connection properties 2) Enter the username and password. Make sure that this username and password are the same as those set on the dial-up server for the dial-up connection. Refer to 8.5.26Select an existing user or the user with new dial-up connection. to set the username and password. 3) 4) Enter the phone number to dial, namely, the number the dial-up server is connected to. Click Dial to activate the network connection. If the connection is activated successfully, the commissioning of the dial-up server is complete. In this case, an icon is displayed in the status area in the toolbar to indicate the connection status. Otherwise, check the settings made on the dial-up server and client, especially the IP address of the dial-up server, the user information and the telephone number. If still failed, the problem may be that the dial-in function of the modem is not activated. Refer to 8.8Activating Modem Dial-in to activate the dial-in function, and then check the connection again as described above.
After you install the modem and check all the system settings, activate the dial-in function as follows: 1) Choose Start -> Programs (P) -> Accessories -> Communications -> HyperTerminal on the dial-up server. Enter a name for the connection, and set the properties. 2) Execute the following command on HyperTerminal to activate the dial-in function of the modem: aat The system prompts OK. 3) Execute the following command to set the ring back tone.
ats0=X X indicates dialing in after how many ring back tones are heard. For example, ats0=5 means to dial in after five ring back tones are heard. The system prompts OK. 4) Execute the following command to save the settings.