ReaPan B27 Features


A reagent for detection
of HLA-B27 Antigen Specificity
Anti-B7 antibody minimizes cross-reactivity
Human Leukocyte Antigen B27 is a class I surface antigen of Anti-B27 antibodies with the B7 antigen
encoded by the B locus in the major histocompatibility complex – lower probability of false positives.
(MHC) that presents microbial antigens to T-Lymphocytes.
The expression of HLA-B27 antigen is associated with the Sensitivity
onset of a class of seronegative spondylo-arthropathies that Gating of T-lymphocytes (CD3+) to reduce
include ankylosing spondylitis, Reiter’s disease, psoriatic background; Use of two clones of Anti-HLA-
arthritis and inflammatory bowel disease. B27 enhances sensitivity of the test.

The ReaPan B27 reagent uses a two-color immunofluorescence Convenience


based method for detecting HLA-B27 antigen on a flow Provided as a dried-down reagent in a ready
cytometry platform. The reagent is provided in a unitized to use format; Easy storage and handling.
dry format containing predispensed amounts of material
adequate for a single test.. This reagent is intended for use on Internal Reference Beads
“open” flow cytometer systems . No external calibration required;
internal reference beads provided in
Qualitative test results are reported on the basis of a RMX every tube. Makes the test robust.
value recorded on the sample acquisition template. RMX value
is a quantification of the relative difference in fluorescent Simple Workflow
staining intensities of the sample and the reference beads. A Lyse-no wash protocol simplifies and reduces
positive sign on the RMX value implies that the sample tested sample processing time significantly.
can be typed as positive. A negative RMX value indicates that
the expression of the HLA-B27 antigen is not sufficient for Ease of Reporting
the sample to be typed as positive. Sign of the RMX value indicates a
positive or negative result.

Ph: +91-80-28378693/5
E-mail: info@reametrix.com
www.reametrix.com
Take dry unitized
dried-down reagent tube
Sample Workflow
(ReaPan B27)

Acquisition and
Add 25µl
+ blood sample
analysis by flow
cytometry

30 15 Add 300µl lysis solution


min min and incubate for 15 min

Vortex for 30 secs and


incubate for 30 min

Sample analysis and gating using ReaPan B27 reagent

Intensity Control T-Lymphocytes


Intensity
control
stained with
reference beads Anti-HLA B27
reference beads
antibodies

Selection of
T-Lymphocytes

Figure 1 Figure 2

CD3-PE-Dy649 fluorescence ver- HLA-B27-PE fluorescence Fluorescent bead intensity


sus side-scatter to capture CD3+ (FL2) (gated from R1 of (FL2) from R3 of Figure 1
(R1) and fluorescence beads (R2) Figure 1) versus Counts versus Counts

Product Information

ReaPan B27 ReaMetrix


Accelerating Innovation

Product Catalogue No.: 25238-00 50-B, II Phase


Peenya Industrial Area
Antibodies used: Peenya, Bangalore 560058, India
Labeled Anti-CD3 (Clone – UCHT1)
Labeled Anti-HLA-B27 Ph: +91-80-28378693/5
(Clones FD705 and ABC-m3) Fax: +91-80-41172451
Unlabeled Anti-B7 (Clone BB7.1)
E-mail: info@reametrix.com,
www.reametrix.com