Professional Documents
Culture Documents
3
CD P/N 7301538 Rev. C
4 4 4 5 5 6 6 6 6 6 7 8 9 9 9 10 10 17 17 18 18 18 18 19 22 22 22 23 23 23 24
Introduction 1 General Specification: Factory defaults parameters: Basic Functionality Password Protection Operation SMS support Inputs Outputs SIM card CS-47 Connections Connection to Runner CS-47 PC software Translations Software installation Configuration of the CS-47 unit Graphical User Interface Communication page Communication with the unit CS47 Audio set Add prefix number Cut prefix number File Options Programming by Telephone Using the CS47 after it was installed Sending SMS Messages Output operation by SMS Activating and Deactivating the System Changing the User Password Handling Received SMS Messages 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 2.1 3 3.1 3.2 4 4.1 4.2 4.3 4.4 4.5 4.6 4.7 5 6 6.1 6.2 6.3 6.4 6.5
Warranty 7
1 Introduction
The CS-47 is a cellular backup to PSTN phone line system. When connected to an alarm control panel, the CS-47 operates as a GSM back up unit to a PSTN line, enabling to re-direct incoming and outgoing calls to the GSM network in case of regular phone line failure.
Battery backup support including charger 2 Operation modes: As backup to PSTN or as GSM unit without PSTN Activation or extinguishing the system by SMS message. Status report by SMS messages Can be programmed by telephone.
Outputs: All 4 outputs defined as N.C, Time=1sec. The outputs configured at the following way: Output 1: operates when there is phone line fail. Output 2: operates when there is problem with GSM network (low RSSI, problem with SIM card, etc) Output 3: operates when there is low power fail. Output 4: operates on trigger system. Trigger Info Manu: Delay time=10sec. System OFF message - CS47 OFF. System ON message - CS47 ON. Miscellaneous Manu: Power fail message - POWER FAIL. Power restore message - POWER RESTORE. Test message - GSM O.K. Phone line fail message - LINE FAIL Phone line restored message - LINE O.K. At default the system defined as "CS-47 as backup to PSTN" mode.
Note: You can load CS47 default file that creates with the installation of the software and placed at the software folder. This file will set all settings to default, except the user password.
This password is not available to end-users. The password must consist of eight characters. User password -used in SMS messages by end-users to trigger various events for the input and output devices defined in the System. This password also used for program the unit via telephone. (Technician code). The password must consist of four characters
1.5 Operation
The system powered by 14VDC with a 12V/1.3A backup battery. The battery is recharged by the system.
1.7 Inputs
The CS-47 offers 4 digital inputs. Every input trigger generates an SMS message to a programmed number and can activate an output.
1.8 Outputs
The CS-47 has 4 programmable outputs. 3 open drain FET outputs, output number 1 is a dry contact relay in parallel. The outputs can be operated locally according to inputs triggering or by SMS (by remote).
CS-47 Connections
TEL-OUT: phone line output supplied to an external system, RJ11 connector or terminal block TEL-IN: PSTN phone line input (main phone line), RJ11 connector or terminal block Main power supply: 14.4 VDC supplied by external power source or panel Battery: Lead Acid 12V / 1.3A Antenna: dual band GSM antenna. Inputs: 4 digital inputs and a key input, in order to trigger an input you need to pull the input low (connect ground) Outputs: 3 digital open drain outputs and one dry contacts relay. Indication LEDs : System OK LED - blinking when the system is ready for use Hook off LED: the LED is on when the external system picks up the phone (goes off hook). Line OK LED - light when PSTN line exists. 7
3 CS-47 PC software
The CS-47 PC software is a graphical user interface (GUI) to be used in order to configure the unit.
3.1 Translations
The GUI can be translated to various languages, the text and the tool tip box can be translated by translating the texts in two files in the software folder: :\Program Files\CS47. The files to be translated are frmedit.txt and frmEditToolTip.txt.
the push button, and in order to download the configuration from the DTU to the unit, you have to press once the push button. 3. Remote configuration - using a cellular modem with sim card in the same network, the tool for the configuration is the PC software. 4. Local configuration -using a Telephone that connected to Line Out.
SMS messages for the relevant input number. Note: Click Copy Phones to copy the phone numbers of input 1 to all other telephone input fields, for use with other inputs.
Defining SMS Messages for Inputs The Mobile Bridge allows the definition of different SMS messages to be sent, depending on the state of the input. For this reason, the Message area of the Input window contains two Message fields. These fields correspond to the two possible states of an input, which are as follows: On -The input device is running (the input has changed from high to low) OFF -The input device is not running (the input has changed from low to high) To define the SMS messages to be sent for each input state, perform the following steps: 1. Click the Input tab. 2. In the Messages area, select the Enable checkbox for each state for which a message is to be enabled. 3. In the Message field corresponding to the enabled state, enter the SMS message to be sent. 11
Note: The Chars Left field displays the permitted number of characters remaining for each message. This is a read-only field. 4. Define the Detect time (in seconds) for the message. The Detect time is the amount of time an event must continue in order to trigger the SMS. 5. Define the Delay time (in seconds) for the message. The Delay time is the amount of time it takes to trigger the SMS after an event has occurred. 6. Define the Repeat time (in minutes) for the message. The Repeat time is the interval at which the SMS is re-sent, if the status of the input does not change. 7. In case you need an output to be activated on an input triggering choose an output number (one of the outputs). Configuring System Outputs The CS-47 allows the configuration of up to four output devices. The configuration procedure for each output device includes defining the normal status of each device. An output can be activated in different ways: Locally - activate an output when an input is triggered. Defined in the input page By SMS - activation of an output by remote using SMS messages. Selected when enabling the checkbox in the output page. By default the Outputs will be operated by events such as PSTN fail, GSM fail, low Power Fail, Key on. Note: if one of the option selected than the other option is disabled.
12
Defining Output Parameters Defining the output parameters includes enabling or disabling each device, and defining the normal state of each. This tab also allows the System Administrator to change the user password, if necessary. To define output parameters, perform the following steps: 1. Click the Output tab. 2. To change the user password, enter the new password in the User Password field. Note: The user password must consist of four characters. 3. Select the Enable checkbox for the first output to be defined. (Enable SMS Control) 4. Select the normal state of the output. Options are: NO - normally open: the output device is normally enabled NC - normally close: the output device is normally disabled 5. Specified Time (pulse) - if an SMS message is sent to trigger an event, specify the length of time (in seconds) for which the event will occur: a. Select the pulse checkbox. Regardless of the event that is triggered (Normally open or normally closed), the pulse parameter changes the output to the opposite status for the specified duration. For example, if the output is normally open, and pulse is set for 25 seconds, the SMS message triggers an event that closes the output for 25 seconds, and then returns it to its normal state. b. Enter the number of seconds for which the event will occur. For more information about SMS activation of outputs refers to chapter: using the CS-47 after installation . Triggering the System The System parameters required for arming or disarming the companys system include the following: Trigger type Trigger confirmation parameters Alarm message parameters In default state the system is triggered which means it checks the inputs and sends SMS, when system is not triggered no messages will be sent. To define these System parameters, perform the following steps: 1. Click the Output tab.
13
2. In the Trigger System area, select the types of triggers by which the outputs can be operated. It is possible to select more than one option. Options are: SMS Key 3. In the Delay Time field, define the number of seconds after the system is triggered that it will actually be armed. 4. Select Trigger Confirmation as relevant. If it is selected, continue to Step 5 (to define the Phone Number field). 5. In the Phone Number field, enter the phone number to which an SMS will be sent confirming that the System has been triggered on or off. 6. In the Alarm OFF -message field, enter the text of the SMS confirming that the alarm has been disarmed. Note: This message can contain up to 15 characters, as noted in the Chars Left field. 7. In the Alarm on -message field, enter the text of the SMS confirming that the alarm has been armed. Note: This message can contain up to 15 characters, as noted in the Chars Left field.
14
Configuration of the low power message: In the Low Power area, define the parameters of the SMS message that is sent if System power drops below 10.5 volts: Select the Enable checkbox. In the Phone number field, enter the phone number to which the SMS message will be sent. In the Message field, enter the text of the SMS message. In the Interval field, enter the number of minutes at which the SMS messages will be sent. As long as this field is set to a value greater than 0, the SMS message is sent repeatedly, until the power flow returns to normal. Note: This message can contain up to 15 characters, as noted in the Chars Left field. Do the same for power restore" message. Configuration of the Test message area In the Test message area, define the parameters of the SMS message that is sent if the System is functioning correctly. Note: In order to receive messages as defined in the System OK area, the user must send the Program Password to the system. This means that only a user with the System Administrator password may activate such messages. 15
a. Select the relevant option for sending messages. There are three possible configurations: SMS request selected -the system sends the message at the administrators request. Enable selected -the message is sent automatically at a predefined interval. Both SMS request and Enable selected -the system sends messages both at a predefined interval, and at administrators request b. In the Phone number field, enter the phone number to which the SMS message will be sent. c. In the Message field, enter the text of the SMS message. d. If Enable was selected in Step 2a, the SMS message is sent repeatedly, at a predefined interval. In the Interval field, enter the number of hours at which the SMS message will be sent. Note: This message can contain up to 15 characters, as noted in the Chars Left field. Select CS-47 operation mode There are 2 operation modes of the CS-47. 1. As backup to PSTN - Only when there is no PSTN line, and the GSM is ok, the unit simulates line and the user, use the GSM. 2. As GSM unit - If the GSM is OK, the unit simulates line, and the user, use the GSM, otherwise the unit let the user the PSTN (even if it not exist) Send to all phone numbers of input 1 If you want to send these messages to more than one phone number, select the option "Send to all phone numbers of input 1" At this case the messages will be sent to the numbers that were entered at Input tab (Input 1). Configuration of the phone line area In this area you define the parameters of the SMS that will be sent when the PSTN line fail and when it restores. a. Select the Enable checkbox.
16
b. In the Phone number field, enter the phone number to which the SMS message will be sent. c. In the Message field, enter the text of the SMS message. Note: This message can contain up to 15 characters, as noted in the Chars Left field. Do the same for phone line restored message. * To change the SMS language, select the desired language at the drop down menu.
17
These buttons appear at the bottom of each window in the user interface. After configuring the System parameters as required, select the relevant option.
18
5 Programming by Telephone
Part of the parameters can be programmed locally by a telephone device that connected to TEL-OUT. This new feature saves to the installer the need to configured by PC. Note : During the programming the PSTN must disconnected from the CS-47. The Technician Default Code for programming: 9999. - Pick up the handset of the telephone device and wait for dial tone. Acknowledge Tones. 1. Changing the Technician code: OOOO 7 NNNN # OOOO- The exist Installer Code NNNN- The new Installer Code. Listen to the confirmation sound. Hung up the handset. 2. Programming Prefix number: 9999 PPP # PPP- Prefix number (up to 3 digits) Listen to the confirmation sound. Hung up the handset.
3. Program Prefix to ignore: 9999 6 PPP # PPP- Prefix number (up to 3 digits) Listen to the confirmation sound. Hung up the handset. 4. Delete Prefix number: 9999 # Listen to the confirmation sound. Hung up the handset.
19
5. Programming Phone Numbers: 9999 N PPPPPPPPPPPPPP # N- phone 1-4 , For phone #1=2 For phone #2=3 For phone #3=4 For phone #4=5 PPPPPP-Phone number up to 14 Digits Listen to the confirmation sound. Hung up the handset. 6. Deleting Phone numbers from Memory: 9999 N # N- phone 1-4 , For phone #1=2 For phone #2=3 For phone #3=4 For phone #4=5 Listen to the confirmation sound. Hung up the handset. 7. Program working mode of the CS-47 9999 8 N # N= 0 As PSTN Backup N= 1 AS GSM only. Listen to the confirmation sound. Hung up the handset. After hang-up the handset wait 15 sec until the unit establish the process. 8. Program Audio In of the CS-47 9999 ** 1 L # L= the voice level, 0 is for default. 1-weakest voice. Listen to the confirmation sound. Hung up the handset.
9. Program Audio Out of the CS-47 9999 ** 2 L # L= the voice level, 0 is for default. 1-weakest voice. Listen to the confirmation sound. Hung up the handset.
10. Back To Factory Default: 9999 12345678 # 12345678- The programming Password of the Unit
20
REMARKS 1. To write sign + in the phones of the SMS, like "+9723972600", press in the phone **. 2. Programming of the phone should be by their order, means first program phone number 1, and then number 2 etc. But its forbidden, to program the first phone and then the forth one. The same is for deleting phone. Delete the most high phone number and decrease. 3. When we program phone for SMS, we get the following parameters: When input 1 activated, the message will be "ALARM". When input 1 deactivated, the message will be "ALARM RESTORED". When input 2 activated, the message will be "SYSTEM ARMED". When input 2 deactivated, the message will be "SYSTEM DISARMED". When input 3 activated, the message will be "PANIC ALARM". When input 3 deactivated, the message will be "PANIC CLEARED ". When input 4 activated, the message will be "SYSTEM BATTERY LOW". When input 4 deactivated, the message will be "SYSTEM BATTERY RESTORE". For low power state, the message will be: "POWER FAIL". And for power restore, the message will be : "POWER RESTORE". An SMS message "LINE FAIL" will be sent when the PSTN line fails, and another SMS message "LINE O.K" will be send when the PSTN line restored.
21
Messages can be sent from any ordinary mobile phone. (Works best with messages in
Text Mode)
Pulse configuration - if the pulse option was defined during System configuration, then
SMS messages will trigger System outputs accordingly.
22
In this example, acac is the user password, 1 is the output number, and n turns the output on.
With a electrical switch key - activate or deactivate the System manually. With an SMS message - activate or deactivate the System from a remote location.
In this case, the SMS message must be constructed as follows: <User Password>on - turn the system on <User Password>OFF - turn the system off
During the cellular programming period (the time during which SMS messages are sent to program the System), the Mobile Bridge will not function for outgoing calls. Only the landline can be used for outgoing calls during this period, which lasts for two to three minutes. However, when SMS messages are sent to control outputs, the Mobile Bridge functions as usual. Note: Spaces are not allowed in either case.
23
7 Warranty
CROW ELECTRONIC ENGINEERING LTD. ("Crow") - WARRANTY POLICY CERTIFICATE This Warranty Certificate is given in favor of the purchaser (hereunder the "Purchaser") purchasing the products directly from Crow or from its authorized distributor. Crow warrants these products to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the last day of the week and year whose numbers are printed on the printed circuit board inside these products (hereunder the "Warranty Period"). Subject to the provisions of this Warranty Certificate, during the Warranty Period, Crow undertakes, at its sole discretion and subject to Crow's procedures, as such procedures are form time to time, to repair or replace, free of charge for materials and/or labor, products proved to be defective in materials or workmanship under normal use and service. Repaired products shall be warranted for the remainder of the original Warranty Period. All transportation costs and in-transit risk of loss or damage related, directly or indirectly, to products returned to Crow for repair or replacement shall be borne solely by the Purchaser. Crow's warranty under this Warranty Certificate does not cover products that is defective (or shall become defective) due to: (a) alteration of the products (or any part thereof) by anyone other than Crow; (b) accident, abuse, negligence, or improper maintenance; (c) failure caused by a product which Crow did not provide; (d) failure caused by software or hardware which Crow did not provide; (e) use or storage other than in accordance with Crows specified operating and storage instructions. There are no warranties, expressed or implied, of merchantability or fitness of the products for a particular purpose or otherwise, which extend beyond the description on the face hereof. This limited Warranty Certificate is the Purchaser's sole and exclusive remedy against Crow and Crow's sole and exclusive liability toward the Purchaser in connection with the products, including without limitation - for defects or malfunctions of the products. This Warranty Certificate replaces all other warranties and liabilities, whether oral, written, (non-mandatory) statutory, contractual, in tort or otherwise. In no case shall Crow be liable to anyone for any consequential or incidental damages (inclusive of loss of profit, and whether occasioned by negligence of the Crow or any third party on its behalf) for breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever. Crow does not represent that these products can not be compromised or circumvented; that these products will prevent any person injury or property loss or damage by burglary, robbery, fire or otherwise; or that these products will in all cases provide adequate warning or protection. Purchaser understands that a properly installed and maintained product may in some cases reduce the risk of burglary, fire, robbery or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss or damage as a result. Consequently, Crow shall have no liability for any personal injury; property damage or any other loss based on claim that these products failed to give any warning. If Crow is held liable, whether directly or indirectly, for any loss or damage with regards to these products, regardless of cause or origin, Crows maximum liability shall not in any case exceed the purchase price of these products, which shall be the complete and exclusive remedy against Crow.
24